For Employer Page 1 of 54 For Contractor

PROJECT: Construction of Expansion of Yashoda Hospital- Phase-1

GRAND SUMMARY

S No Item Supply Installation Total Remarks

1 EXTERNAL ELECTRIFICATION

2 INTERNAL ELECTRIFICATION

TOTAL AMOUNT

In Words:

Page 2: Electrical BOQ R0!31!08-2013

For Employer Page 2 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

A EXTERNAL ELECTRIFICATION

1 MV Panels

NOTES:

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

Supply Installation, erection, testing and commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted MV panel made out of 2mm thick CRCA sheet for main frame and 1.6mm thick partitions after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified.

The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. The panel shall be got fabricated from manufacturers with CPRI Test certificate only. The PCC shall have atleast two spare cubicles of the maximum rating( MCCBs maximum rating). The size of all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on U channels including supply and fixing of the same. Every ACB shall be provided with ON/OFF /Trip Indication lamps of LED type. All MCCBs shall provide with spreader links and rotary handle. All the panels shall be conforming to technical specifications/Datasheets and Single Line Diagram attached with this BoQ.

a) All electrically operated breakers shall have provision for local & remote operations

Page 3: Electrical BOQ R0!31!08-2013

For Employer Page 3 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

c) All CTs shall be resin cast colour coded and of 15VA burden

1.1 No 1

b) One no. auto/manual selector switch with 2no. Contacts shall be provided

d) All wiring from RS485 energy meter and for PLC/BMS operated status feed necessary shall be brought to a common terminal blockLOCAL ISOLATION PANEL (OUTDOOR KIOSK TYPE)

Supply, Installation, erection, testing and commissioning of Local Isolation Panel as per detailes given below. The Panel will be provided with phase indication lamps, volt meter, and Amp. Meter and selector switches in MS Weather Proof Enclosure. The enclosure shall have suitable space to terminate specified No. of cables for incomer and outgoing side

Incomer feeder-1: 4000A, 50KA, 4Pole, Electrically operated drawout type, ACB with releases for Overcurrent, Short circuit and earth fault and with UV release and with required number of Potential free contacts for Electrical interlocking - 1set (EB Incomer)

Incomer feeder-2: 2500A, 50KA, 4Pole, Electrically operated drawout type, ACB with releases for Overcurrent, Short circuit and earth fault and with UV release and with required number of Potential free contacts for Electrical interlocking - 1set (1010kVA DG Incomer)

Busbars : 4000A, 50kA for 1sec, TPN, Aluminum Busbars – 1set

Page 4: Electrical BOQ R0!31!08-2013

For Employer Page 4 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

Outgoings :

Indication & Metering :Incoming Side:

a

b

c

Interlocking : Necessary electrical interlocking between the two Incomers shall be provided such that both cannot be in "ON" condition at the same time, to prevent unsynchronised mixing of sources

Outgoing feeder-1: 3200A, 50KA, 4Pole, Electrically operated drawout type, ACB with releases for Overcurrent, Short circuit and earth fault and with required number of Potential free contacts for remote monitoring - 1set (to new PCC under Phase-1)

Outgoing feeder-2: 1600A, 50KA, 4Pole, Electrically operated drawout type, ACB with releases for Overcurrent, Short circuit and earth fault and with required number of Potential free contacts for remote monitoring - 1set (to existing PCC under Phase-1 and to be re-used for new PCC under Phase-2 after completion of Phase-1)

LED Phase indication lamps with individual fuse and control with toggle switches- 2sets0-500V Digital Voltmeter with selector switch and fuses- 2sets

0-4000A Digital Ammeter with resin cast CTs of ratio 4000-2000/5A, Class 1Accuracy and 15VA burden and selector switch – 1set

Page 5: Electrical BOQ R0!31!08-2013

For Employer Page 5 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

d

e

Outgoing Side:

a

b

c

1.2 Main PCC No 1

0-2500A Digital Ammeter with resin cast CTs of ratio 2500/5A, Class 1Accuracy and 15VA burden and selector switch – 1set

CT operated Electronic Digital Load Manger with RS 485connectivity with suitable ratio & burden resin cast CT's– 2sets

0-3200A Digital Ammeter with resin cast CTs of ratio 3200-1600/5A, Class 1Accuracy and 15VA burden and selector switch – 1set

0-1600A Digital Ammeter with resin cast CTs of ratio 1600/5A, Class 1Accuracy and 15VA burden and selector switch – 1set

CT operated Dual Source Electronic Digital Energy Meter with RS 485connectivity with suitable ratio & burden resin cast CT's– 2sets

Notes: 1. All Breakers shall have minimum 2NO+2NC Potential free contactors for status indications

2. Panel shall have adequate space provision for two nos. of fixed type capacitor banks feeders & two nos of Capacitor units of 100kVAr capacity at a later date.

Incomer-1: 3200A, 50KA, 4Pole, Electrically operated draw out type, ACB with releases for Over current, Short circuit & earth fault and with UV release and with required number of Potential free contacts for Electrical interlocking - 1set

Page 6: Electrical BOQ R0!31!08-2013

For Employer Page 6 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

Outgoings :

Spare Feeders:

Incomer-2: 800A, 50KA, 4Pole, Electrically operated drawout type, ACB with releases for Over current, Short circuit & earth fault and with UV release and with required number of Potential free contacts for Electrical interlocking - 1set

Bus-coupler: 800A, 50KA, 4Pole, Electrically operated drawout type, ACB without protection releases but with UV release and with required number of Potential free contacts for Electrical interlocking - 1set

Busbars : 3200A, 50kA for 1sec, TPN, Aluminum Bus-bars – 1set

Interlocking : Necessary electrical interlocking between the two Incomers & Bus-coupler shall be provided such that any time only two out of the three breaker can be made on, to prevent unsynchronised mixing of sources

1600A, 50KA, TP ACB with neutral link -1No. 630A, 50KA, TP, MCCB with neutral link -2No.400A, 35KA, TP, MCCB with neutral link -2Nos250A, 35KA, TP, MCCB with neutral link -6Nos160A, 35KA, TP, MCCB with neutral link -3Nos.100A, 25KA, TP, MCCB with neutral link -1No. 63A, 25KA, TP, MCCB with neutral link -3NosTransient Voltage Surge Suppressor (TVSS) -1Set

1600A, 50KA, TP ACB with neutral link -1No. 250A, 35KA, TP, MCCB with neutral link -1Nos

Page 7: Electrical BOQ R0!31!08-2013

For Employer Page 7 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

Indication & Metering :Incoming Side:

a

b

c

d

e

f

gOutgoing Side:

a

b

160A, 35KA, TP, MCCB with neutral link -1No.100A, 25KA, TP, MCCB with neutral link -1No.

LED Phase indication lamps with individual fuse and control with toggle switches- 2sets0-500V Digital Voltmeter with selector switch and fuses- 2sets

0-3200A Digital Ammeter with resin cast CTs of ratio 3200-1600/5A, Class 1Accuracy and 15VA burden and selector switch – 1set

3200-1600/5A 15VA CT in 'R' Phase for APFCR – 1set0-800A Digital Ammeter with resin cast CTs of ratio 800/5A, Class 1Accuracy and 15VA burden and selector switch – 1set

CT operated Electronic Digital Load Manger with RS 485connectivity with suitable ratio & burden resin cast CT's– 2sets

KW Transducers with required CT with 0-10V Output – 2sets

All outgoings shall be provided with Digital Ammeter of suitable range with resin cast CTs of Class-1 Accuracy & 15VA burden and selector switch – 21Sets

CT operated Dual Source Electronic Digital Energy Meter with RS 485connectivity with suitable ratio & burden resin cast CT's– 20sets (except for AHF Feeder)

Page 8: Electrical BOQ R0!31!08-2013

For Employer Page 8 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

1.3 AC Panel No 1

Outgoings :

Spares:

KW Transducers with required CT with 0-10V Output – 1set (AC Panel feeder)

Note: All Outgoing Breakers shall have minimum 2NO+2NC Potential free contactors for status indications

Incomer: 1600A, 50KA, Triple Pole and Neutral link, Electrically operated drawout type, ACB with releases for Overcurrent, Short circuit & earth fault and with required number of Potential free contacts for status monitoring - 1set

Busbars : 1600A, 50kA for 1sec, TPN, Aluminum Bus-bars – 1set

630A, 35KA, TP, MCCB with neutral link -3Nos250A, 25KA, TP, MCCB with neutral link -0Nos125A, 25KA, TP, MCCB with neutral link -2Nos

75HP Motor starter: 250A TP MCCB with Star-Delta Starter consisting of Star, Delta and Main contactor, 2NO+2NC Potential free contactor, thermal overload relay with single phasing preventor, on/off/trip indications & local/ remote selector switch– 3sets

20HP Motor starter: 63A TP MCCB with Star-Delta Starter consisting of Star, Delta and Main contactor, 2NO+2NC Potential free contactor, thermal overload relay with single phasing preventor, on/off/trip indications & local/ remote selector switch– 3sets

Page 9: Electrical BOQ R0!31!08-2013

For Employer Page 9 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

Indication & Metering :Incoming Side:

a

b

c

Outgoing Side:

a

630A, 35KA, TP, MCCB with neutral link -1Nos250A, 25KA, TP, MCCB with neutral link -1Nos

75HP Motor starter: 250A TP MCCB with Star-Delta Starter consisting of Star, Delta and Main contactor, 2NO+2NC Potential free contactor, thermal overload relay with single phasing preventor, on/off/trip indications & local/ remote selector switch– 1set

20HP Motor starter: 63A TP MCCB with Star-Delta Starter consisting of Star, Delta and Main contactor, 2NO+2NC Potential free contactor, thermal overload relay with single phasing preventor, on/off/trip indications & local/ remote selector switch– 1set

LED Phase indication lamps with individual fuse and control with toggle switches- 1set0-500V Digital Voltmeter with selector switch and fuses- 1set 0-1600A Digital Ammeter with resin cast CTs of ratio 1600/5A, Class 1Accuracy and 15VA burden and selector switch – 1set

All outgoings shall be provided with Digital Ammeter of suitable range with resin cast CTs of Class-1 Accuracy & 15VA burden and selector switch – 11Sets

Page 10: Electrical BOQ R0!31!08-2013

For Employer Page 10 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

1.4 AC Secondary Pumps Panel No 0

Outgoings :

Spares:

Indication & Metering :Incoming Side:

Incomer: 250A, 25KA, Triple Pole and Neutral link, MCCB with shunt trip coil, protection releases for Overcurrent, Short circuit & CBCT based Earth Leakage Relay - 1set

Busbars : 250A, 25kA for 1sec, TPN, Aluminum Bus-bars – 1set

30HP Motor starter: 63A TP MCCB with Space provision for Variable Frequency Drive (VFD to be given by AC Package Vendor) and with by-pass Star-Delta Starter consisting of Star, Delta and Main contactor, 2NO+2NC Potential free contactor, thermal overload relay with single phasing preventor, on/off/trip indications & local/ remote selector switch– 3sets

30HP Motor starter: 63A TP MCCB with Space provision for Variable Frequency Drive (VFD to be given by AC Package Vendor) and with by-pass Star-Delta Starter consisting of Star, Delta and Main contactor, 2NO+2NC Potential free contactor, thermal overload relay with single phasing preventor, on/off/trip indications & local/ remote selector switch– 1set

Page 11: Electrical BOQ R0!31!08-2013

For Employer Page 11 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

a

b

c

Outgoing Side:

a

1.5 AC Cooling Water System Panel No 1

Outgoings :

Spares:

Indication & Metering :

LED Phase indication lamps with individual fuse and control with toggle switches- 1set0-500V Digital Voltmeter with selector switch and fuses- 1set 0-250A Digital Ammeter with resin cast CTs of ratio 250/5A, Class 1Accuracy and 15VA burden and selector switch – 1set

All outgoings shall be provided with Digital Ammeter of suitable range with resin cast CTs of Class-1 Accuracy & 15VA burden and selector switch – 5Sets

Incomer: 125A, 25KA, Triple Pole and Neutral link, MCCB with shunt trip coil, protection releases for Overcurrent, Short circuit & CBCT based Earth Leakage Relay - 1set

Busbars : 125A, 25kA for 1sec, TPN, Aluminum Bus-bars – 1set

15HP Motor starter: TP MPCB with Star-Delta Starter consisting of Star, Delta and Main contactor, 2NO+2NC Potential free contactor, on/off/trip indications & local/ remote selector switch– 3sets

15HP Motor starter: TP MPCB with Star-Delta Starter consisting of Star, Delta and Main contactor, 2NO+2NC Potential free contactor, on/off/trip indications & local/ remote selector switch– 1set

Page 12: Electrical BOQ R0!31!08-2013

For Employer Page 12 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

Incoming Side:

a

b

c

Outgoing Side:

a

1.6 Centralised Pumps Panel No 1

Outgoings :

Spares:

LED Phase indication lamps with individual fuse and control with toggle switches- 1set0-500V Digital Voltmeter with selector switch and fuses- 1set 0-125A Digital Ammeter with resin cast CTs of ratio 125/5A, Class 1Accuracy and 15VA burden and selector switch – 1set

All outgoings shall be provided with Digital Ammeter of suitable range with resin cast CTs of Class-1 Accuracy & 15VA burden and selector switch –4Sets

Incomer: 250A, 25KA, Triple Pole and Neutral link, MCCB with shunt trip coil, protection releases for Overcurrent, Short circuit & CBCT based Earth Leakage Relay - 1set

Busbars : 250A, 25kA for 1sec, TPN, Aluminum Bus-bars – 1set

5HP Motor starter: TP MPCB with Direct-on-line Starter consisting of Main contactor, 2NO+2NC Potential free contactor, on/off/trip indications & Auto/ manual selector switch and Water Level Controller– 8sets

3HP Motor starter: TP MPCB with Direct-on-line Starter consisting of Main contactor, 2NO+2NC Potential free contactor, on/off/trip indications & Auto/ manual selector switch – 5sets

32A, 25KA, TP, MCCB with neutral link -2Nos

Page 13: Electrical BOQ R0!31!08-2013

For Employer Page 13 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

Indication & Metering :Incoming Side:

a

b

c

1.7 Main Lighting Panel-1 No 1

5HP Motor starter: TP MPCB with Direct-on-line Starter consisting of Main contactor, 2NO+2NC Potential free contactor, on/off/trip indications & Auto/ manual selector switch and Water Level Controller– 1sets

3HP Motor starter: TP MPCB with Direct-on-line Starter consisting of Main contactor, 2NO+2NC Potential free contactor, on/off/trip indications & Auto/ manual selector switch and Water Level Controller– 1sets

32A, 25KA, TP, MCCB with neutral link -1No.

LED Phase indication lamps with individual fuse and control with toggle switches- 1set0-500V Digital Voltmeter with selector switch and fuses- 1set 0-250A Digital Ammeter with resin cast CTs of ratio 250/5A, Class 1Accuracy and 15VA burden and selector switch – 1set

Incomer: 250A, 25KA, Triple Pole and Neutral link, MCCB with shunt trip coil, protection releases for Overcurrent, Short circuit & CBCT based Earth Leakage Relay - 1set

Busbars : 250A, 25kA for 1sec, TPN, Aluminum Bus-bars – 1set

Page 14: Electrical BOQ R0!31!08-2013

For Employer Page 14 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

Outgoings :

Spares:

Indication & Metering :

a

b

c

d

1.8 UPS Output Distribution Panel No 1

Outgoings :

Spare Feeders:

63A, 25KA TPN MCCBs – 15Nos

63A, 25KA TPN MCCBs – 4Nos

LED Phase indication lamps with individual fuse and control with toggle switches- 1set0-500V Digital Voltmeter with selector switch and fuses- 1set 0-250A Digital Ammeter with resin cast CTs of ratio 250/5A, Class 1Accuracy and 15VA burden and selector switch – 1set

CT operated Dual Source Electronic Digital Energy Meter with RS 485connectivity with suitable ratio & burden resin cast CT's– 1sets

Incomer-1: 250A, 35KA, TPN, MCCB - 1set Incomer-2: 250A, 35KA, TPN, MCCB - 1set Bus-coupler: 250A, 35KA, TPN, MCCB - 1set Busbars :250A, 35kA for 1sec, TPN, Aluminum Bus-bars – 1set

Interlocking : Necessary mechanical interlocking between the two Incomers and Bus-coupler shall be provided such that only two out of the three MCCBs can be closed at the same time,

63A, 25KA, TP, MCCB with neutral link -11Nos.

63A, 25KA, TP, MCCB with neutral link -4Nos.

Page 15: Electrical BOQ R0!31!08-2013

For Employer Page 15 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

Indication & Metering :Incoming Side:

a

b

e

d

Outgoing Side:

a

1.9 Lifts Panel-1 No 1

Outgoings :

Spares:

LED Phase indication lamps with individual fuse and control with toggle switches- 2sets0-500V Digital Voltmeter with selector switch and fuses- 2sets 0-250A Digital Ammeter with resin cast CTs of ratio 250/5A, Class 1Accuracy and 15VA burden and selector switch – 2sets

CT operated Dual Source Electronic Digital Energy Meter with RS 485connectivity with suitable ratio & burden resin cast CT's– 2 sets

All outgoings shall be provided with Digital Ammeter of suitable range with resin cast CTs of Class-1 Accuracy & 15VA burden and selector switch – 15Sets

Incomers: 125A, 25KA, Triple Pole and Neutral link, MCCB with shunt trip coil, protection releases for Overcurrent, Short circuit & CBCT based Earth Leakage Relay - 2sets

ATS: 125A, 3P, Auto-Transfer Switch with provision for power supply from two feeders. Busbars : 125A, 25kA for 1sec, TPN, Aluminum Bus-bars – 1set

63A, 10KA TPN MCBs – 6Nos

63A, 10KA TPN MCBs – 2Nos

Page 16: Electrical BOQ R0!31!08-2013

For Employer Page 16 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

Indication & Metering :

a

b

c

d

1.1 Power Panel-1 No 1

Outgoings :

Spares:

Indication & Metering :

a

b

c

LED Phase indication lamps with individual fuse and control with toggle switches- 1set0-500V Digital Voltmeter with selector switch and fuses- 1set 0-250A Digital Ammeter with resin cast CTs of ratio 250/5A, Class 1Accuracy and 15VA burden and selector switch – 1set

CT operated Dual Source Electronic Digital Energy Meter with RS 485connectivity with suitable ratio & burden resin cast CT's– 1set

Incomer: 630A, 35KA, Triple Pole and Neutral link, MCCB with shunt trip coil, protection releases for Overcurrent, Short circuit & CBCT based Earth Leakage Relay - 1set

Busbars : 630A, 35kA for 1sec, TPN, Aluminum Bus-bars – 1set

100A, 25KA TPN MCCBs – 16Nos

100A, 25KA TPN MCCBs – 3Nos

LED Phase indication lamps with individual fuse and control with toggle switches- 1set0-500V Digital Voltmeter with selector switch and fuses- 1set 0-600A Digital Ammeter with resin cast CTs of ratio 600/5A, Class 1Accuracy and 15VA burden and selector switch – 1set

Page 17: Electrical BOQ R0!31!08-2013

For Employer Page 17 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

d

2 MV Cables

2.1 For Aluminum cablesa 3.5 core 300Sq.mm (A2XFY) mtr 1200

laying on tray is 400 mtrs and in ground is 800mtrsb 3.5 core 185Sq.mm (A2XFY) mtr 50c 3.5 core 120Sq.mm (A2XFY) mtr 60d 3.5 core 95Sq.mm (A2XFY) mtr 430e 3.5 core 70Sq.mm (A2XFY) mtr 250f 3.5 core 50Sq.mm (A2XFY) mtr 50g 3.5 core 35Sq.mm (A2XFY) mtr 50h 3.5 core 25Sq.mm (A2XFY) mtr 900

2.2 Copper Cables

CT operated Dual Source Electronic Digital Energy Meter with RS 485connectivity with suitable ratio & burden resin cast CT's– 1sets

Supply, laying testing and commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor under ground cable, in built up cable trench/ already laid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protection with sand and bricks at sides and top and cable route markers at every 15mtr. interval and also at the turnings. The cable shall conform to IS 7098/ Part I.

Page 18: Electrical BOQ R0!31!08-2013

For Employer Page 18 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

j 4core 10sq.mm (2XFY) mtr 1350k 4core 6sq.mm (2XFY) mtr 1080l 3core 10sq.mm (2XFY) mtr 300n 3core 6sq.mm (2XFY) mtr 150o 3core 2.5sq.mm (2XFY) mtr 1200j 1 core 50Sq.mm (2XFY) mtr 3003 End terminations for MV Cables

3.1

a 3.5 core 300Sq.mm (A2XFY) Nos 40c 3.5 core 185Sq.mm (A2XFY) Nos 2d 3.5 core 120Sq.mm (A2XFY) Nos 4e 3.5 core 95Sq.mm (A2XFY) Nos 18f 3.5 core 70Sq.mm (A2XFY) Nos 10g 3.5 core 50Sq.mm (A2XFY) Nos 2h 3.5 core 35Sq.mm (A2XFY) Nos 2I. 3.5 core 25Sq.mm (A2XFY) Nos 36

3.2 End terminations for Copper Cables

Supply, laying testing and commissioning of following size 1.1KV grade XLPE insulated armoured multistrand copper conductor under ground cable, in built up cable trench/ already laid RCC hume pipe or on cable tray with all installation materials. The cable shall conform to IS 7098/Part I

Providing Indoor ordinary end terminations for the cable specified above with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland.

Page 19: Electrical BOQ R0!31!08-2013

For Employer Page 19 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

k 4core 10sq.mm (2XFY) Nos 54l 4core 6sq.mm (2XFY) Nos 44

m 3core 10sq.mm (2XFY) Nos 12n 3core 6sq.mm (2XFY) Nos 6o 3core 2.5sq.mm (2XFY) Nos 44j 1 core 50Sq.mm (2XFY) Nos 20

13 Cable trays

13.1 1000mm wide Mtrs 15013.1 750mm wide Mtrs 10013.2 450mm wide Mtrs 10013.3 300mm wide Mtrs 15013.4 150mm wide Mtrs 10014 MS Supporting Angles Tons 1.5

15 Earthing

Providing Indoor ordinary end terminations for the cable specified above with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland.

Supply and fabrication and installation of following size perforated/ladder type GI Tray of 2mm thick, 50mm Height, GI Sheet and supported with Screw type rod anchored from ceiling with 10mm dia suitable length anchor bolts including supply of necessary bends/ elbows etc

Supply and fixing of cable Trays supports made with MS angles and flat Including fabrication and all necessary clamps etc.

Page 20: Electrical BOQ R0!31!08-2013

For Employer Page 20 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

15.1 Copper Plate Earthing

15.3 GI Pipe Earthing

15.4 Copper Plate Earthing

15.4 Earth Strips

Providing standard Copper Plate Earth station, with 600X600X3.15mm thick copper plate including construction of brick pedestal, providing meshed funnel, CI cover and other civil Engineering works, spreading a homogeneous mixture of salt charcoal around the plate etc, completely as per IS 3043,1987 or latest revision. (For 500kVA DG Set Neutrals)

Providing standard G.I. Pipe Earth station, with 38mm dia. 2500mm long class 'B' G.I. pipe including construction of brick pedestal, providing meshed funnel, CI cover and other civil Engineering works, spreading a homogeneous mixture of salt charcoal around the pipe etc, completely as per IS 3043, 1987 or latest revision. (For LT & APFCR Panels)

Providing standard Copper Plate Earth station, with 600X600X3.15mm thick copper plate including construction of brick pedestal, providing meshed funnel, CI cover and other civil Engineering works, spreading a homogeneous mixture of salt charcoal around the plate etc, completely as per IS 3043,1987 or latest revision. (For Sensitive Medical Equipment)

Page 21: Electrical BOQ R0!31!08-2013

For Employer Page 21 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

15.4.a 50X6mm GI strip Mtrs 10015.4.b 40X6mmGI strip Mtrs 10015.4.c 25X6mm GI strip Mtrs 30015.4.d 50X6mm copper strip Mtrs 20

16 Safety Accessories

a Nos 8

b Supply and fixing of CO2 Fire Extinguishers 4.5Kg capacity Nos 2c Supply of Hand Gloves -1.1KV grade Pairs 2

16.5 Supply of First Aid boxes Nos 1

16.6 Nos 1

16.7 Supply and Fixing of Laminated SLD-A1size Nos 116.8 Supply and fixing of Danger Notice boards Nos 417 LIGHTNING PROTECTION

a Nos 1

b Sets 1

c Sets 1

Supply and laying of following size earth strips including excavation and refilling of earth when laid in ground and with all fixing accessories when laid inside the building including all necessary interconnections with earth station and Panels

Supply and laying of 12mm thick 1.1KV grade Rubber Mats of size1000mm x2000mm

Supply and Fixing of Laminated First Aid Charts in Hindi , English & Local language

Supply ,Installation ,testing & commissioning of SI-60 ESE Interceptor -of stainless steel metal and dry.

Supply ,Installation ,testing & commissioning of GI mast with base and guying support for ESE terminal

Supply ,Installation ,testing & commissioning of U- bolt and clamps for fixing of GI mast (2pcs)

Page 22: Electrical BOQ R0!31!08-2013

For Employer Page 22 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

d Nos 1

e Mtr 40

f Nos 2

18 LIASONING WITH STATUTORY AUTHORITIESa) Liasoning with CEIG for Drawings and Installation approvals

Including all incidental costs. Note : necessary statutory fees shall be paid by Client LS

SUB TOTAL OF EXTERNAL ELECTRIFICATIONI INTERNAL ELECTRIFICATION

LIGHTING DISTRIBUTION1.1 Light Point (Primary point) :

Supply & Wiring for light point with 2 runsof1.5 sq.mm650V grade PVCinsulated Copper conductormulti strand wires along with one runof 1.5sq.mm copper earth wire in 25mm dia

Supply ,Installation ,testing & commissioning of Lightning Event counter

Supply and laying of 25X6mm GI strip and with all fixing accessories when laid inside the building including Saddles and Fixers for down conductor all necessary interconnections with earth station and Panels

Providing Maintenance free (Chemical type) Earth station,with safe earthing electrode of 40mm dia, 3500mm long with concentric GI Pipes filled with Chemical for anti corrosion including spreading of Chemical around earth station to retain moisture and construction of brick pedestal, CI cover and other civil Engineering works, etc completely as required

Page 23: Electrical BOQ R0!31!08-2013

For Employer Page 23 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

heavy guage PVC conduit concealed in wall/ Ceiling includingfixing of 5Amp. Modular type switch in suitable anodised GI box completewith fixing 3way Ceiling roseincluding interconnections as required. Nos 1050

1.2 Secondary light point : Same as Item Nos 8501.1 But point looped from Primarypoint. (without separate switch)

1.3 Two way switch point: (Primary) Nos 40wiring same as item 1.1above but for Two way switch pointwith 2Nos 2way switches andcontrolling one light.

1.4 Ceiling Fan Point: Nos 150Wiring similar to item 1.1 above but forceiling fan point including GI boxwith 5Amp. control switch and 300WElectronic fan regulator

1.5 Wall mounted Fan Point: Nos 50Wiring similar to item 1.1 above but forwall mounted fan point including GI boxwith 5Amp. control switch

1.6 Exhaust fan point: Nos 50wiring same as item 1.1 above

Page 24: Electrical BOQ R0!31!08-2013

For Employer Page 24 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

but for Exhaust fan pointincluding the supply of the same

1.7 5A Switch socket outlets (independent type) Nos 500wiring same as item 1.1 above but for 5A2/3 pin socket outlet including the supply of the same

1.8 5A Switch socket outlet with Switch (UPS) Nos 800(independent type) 5A2/3 pin socket outlet including the supply of the same.

1.9 5A. Switch socket outlet: (Dependant) Nos 210Fixing of 5Amp.2/3 pin combined switchsocket outlet in lighting control board including interconnections.

1.10 Supply and fixing of flush type 1X13/5A, intel type Nos 1505 pin combined switch socket outlets in the modular typeAnodized box including 1no 16A Switch and front platesincluding interconnections. (RAW POWER)

1.11 Supply and fixing of flush type 1X13/5A, intel type Nos 1005 pin combined switch socket outlets in the modular typeAnodized box including 1no 16A Switch and front platesincluding interconnections. (UPS)

1.12 Supply and fixing of flush type 2X13/5A, intel type Nos 1505 pin combined switch socket outlets in the modular typeAnodized box including 1no 16A Switch and front platesincluding interconnections.

Page 25: Electrical BOQ R0!31!08-2013

For Employer Page 25 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

1.13 6A / 16A Socket point : Nos 835Supply of Fixing of 6A / 16A modularswitch & socket in suitable anodized box complete with fixing accessories including interconnections as required.

1.14 Nos 75Supply of Fixing of 6A / 16A modularswitch & socket in suitable anodized box complete with fixing accessories including interconnections as required.

1.15 Nos 80wiring same as item 1.1 above but for 5A2/3 pin socket outlet (without switch)including the supply of the same

1.16 Nos 30Supply & Fixing of 6A / 16A modularsocket (without switch) in suitable anodized box complete with fixing accessories including interconnections as required.

2 RUN OF MAINS:2.1

RMT 23500

6A / 16A Socket point : (for UPS)

5A socket outlets for Indoor AC Cassatt Unit

6A/16A Socket point : Indoor AC ductable Unit

Supply and wiring with 2runs of 2.5sq.mm copper conductor wires with 1run of 2.5sq.mm copper earth wire from DB to switch boards as circuit wires in 2mm thick PVC conduits, including with necessary fixing accessories.

Page 26: Electrical BOQ R0!31!08-2013

For Employer Page 26 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

2.2

RMT 16500

2.3

RMT 300

2.4

RMT 450

3.0 Light/Fan FixturesInstallation of following typeFluorescent/Compact fluorescent/Incandescentlight fixtures on wall/ceiling including all fixingAccessories such as down rod of 750mmlength, leads,teak wood round block etccomplete as required. The fluorescent /CFL /Metal Halide fixtures shall be complete with low losscopper ballast PF improvement capacitor,Bipinrotor type lamp holder, starter, starter base, allprewired upto the terminal block.

a) 1X14W Recessed mounting round type Nos 1100LED Light fixture

Supply and wiring with 2runs of 4sq.mm copper conductor wires with 1run of 4sq.mm copper earth wire from DB to15A/20A sockets in 2mm thick PVC conduits, including with necessary fixing accessories.

Supply and wiring with 4runs of 6sq.mm copper conductor wires with 2runs of 6sq.mm copper earth wire from Rising Main /Panel to LDBs as circuit wires in 2mm thick PVC conduits, including with necessary fixing accessories.

Supply and wiring with 4runs of 10sq.mm copper conductor wires with 2runs of 10sq.mm copper earth wire from Rising Main / Panel to PDBs as circuit wires in 2mm thick PVC conduits, including with necessary fixing accessories.

Page 27: Electrical BOQ R0!31!08-2013

For Employer Page 27 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

b) 1X28W Recessed mounting round type Nos 100LED Light fixture

c) 1X40W Wall mounted Light fixture Nos 200d) 1X28W(T5) Box type Light fixture Nos 400d) 60W wall/ceiling mounted Nos 60

Bulk head light fixturee) Supply & Installation of 1200mm Sweep Nos 150

Ceiling fan complete with all accessories including Fan Regulator

f) Supply & Installation of Wall mounted fan Nos 20complete with all accessories

4.0 Installation of Heavy/Light duty typeExhaust fans of following size sweep withMetallic blades gravity louvres shuttersincluding all accessories/Installation materials required.

a) 300mm sweep,1400RPM Light duty Nos 26Corrosion proof

b) 380mm sweep,900RPM Heavy duty Nos 24Corrosion proof

5.0 TP MCB DOUBLE DOORDISTRIBUTION BOARDSSupply, Installation, Testing andcommissioning of TP MCB double doordistribution boards dust and verminprotected and rated for 415V three Phase

Page 28: Electrical BOQ R0!31!08-2013

For Employer Page 28 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

AC supply operation including incomingMCB/ELCB as per specifications andrequired capacity neutral bar and Earthterminal complete as required and installed inflush with wall including all fixing materialsrequired. MCBs shall conform to IS:8828and ELCB/RCCB shall conform toIS:12640.(Makes: MDS/Schneider/L&T-Hager)

a) 4 way TP MCB DB with 12Nos. Nos 15 6A SPMCBs as out goings and 4pole 40Amp,100mA sensitivity ELCB as incomer (LDB)

b) 4 way TP MCB DB with 12Nos. Nos 14 16A/25A SPMCBs as out goings and 4pole 40Amp MCB as incomer (ELDB)

c) 6 way TP MCB DB with 18Nos. Nos 20 6A SPMCBs as out goings and 4pole 40Amp,100mA sensitivity ELCB as incomer (LDB/PDB)

e) 8 way TP MCB DB with 24Nos. Nos 106A SPMCBs as out goings and 4pole 63Amp,100mA sensitivity ELCB as incomer (PDB)

f) 8 way TP MCB DB with 24Nos. Nos 1016A/25A SPMCBs as out goings and 4pole 63Amp MCB as incomer (UDB)

g) Nos 106way DPXMCCB Vertical DB with 6nos 32/40A

Page 29: Electrical BOQ R0!31!08-2013

For Employer Page 29 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

h) Nos 10

i) Nos 10

g) Nos 4TP MCBs,as outgoings and 63A FP MCB as incomer.(Lift PDB)

B COMMUNICATION SYSTEM1.0 Telephone/TV/LAN wiring

Supply & Laying of following size 1.5mmthick PVC conduit concealed in wall/ceiling/floor/ column including supply anddrawing of 12SWG GI wire as fish wire forlaying of Telephone cables at a laterstage and supply of all fixing materialscomplete as required.

a) 20mm mtr 4000 b) 25mm mtr 6000

1.1 Nos 200

TP MCBs, as outgoings and 63A,25KA,TP+NL MCCB with 63A 25KA 4P,ATS as incomer.(UDB)6way DPXMCCB Vertical type DB with 6nos 32/40A

TP MCBs, as outgoings and 63A,25KA,TP+NL MCCB with 63A 25KA 4P,ATS as incomer.(UDB)8way DPXMCCB Vertical type DB with 6nos 32/40A

TP MCBs, as outgoings and 100A,25KA,TP+NL MCCB with 100A 25KA 4P,ATS as incomer.(PDB)6 way TPNMCB Vertical type DB with 6nos 32/40A

Supply & Fixing of modular type DUAL I/O ports for LAN & Telephone outlets with anodized GI box and front plate complete as required.

Page 30: Electrical BOQ R0!31!08-2013

For Employer Page 30 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

1.2 Nos 120

1.3 Nos 50

1.4 Supply & Fixing of modular type TV Nos 100 Socket outlet with anodized GI box and frontplate complete as required.

1.5 Supply & Laying of Cat 6 cable in existing PVC mtr 17100 conduit/raceways including connection etc,.(for Telephone & LAN)

2.0 Supply & Laying of RG 11 Co-axial mtr 150 TV cable in existing conduit

3.0 Supply & Laying of RG 6Co-axial mtr 3000 TV cable in existing conduit

4.0 TV Tap off Boxa) Supply and fixing of 8 way TV Tap off in nos 15

2mm thick Ms box covered with 3mm thickhylam sheet.

5.0 nos 4 and supply of all fixing materials complete as required.

C RACEWAYS AND CABLE TRAYS

Supply & Fixing of modular type Single I/O ports for LAN Outlet with anodized GI box and front plate complete as required.

Supply & Fixing of modular type Single I/O ports for Telephone outlets with anodized GI box and front plate complete as required.

Supply and fixing 1.5Feet ceiling mount kit for Projector

Page 31: Electrical BOQ R0!31!08-2013

For Employer Page 31 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

1.01.1 25mm Mtrs RO1.2 32mm Mtrs RO

22.1 25x25mm 1.6mm thick Aluminium Box Section as Race way Mtrs RO2.2 50x25mm 1.6mm thick Aluminium Box Section as Race way Mtrs RO2.3 80x40mm 1.6mm thick Aluminium Box Section as Race way Mtrs RO2.4 100x40mm 1.6mm thick Aluminium Box Section as Race way Mtrs RO

33.1 125X125X40mm deep junction boxes nos RO3.2 300X300X50mm deep junction boxes nos RO3.3 450X450X50mm deep junction boxes nos RO

Supply and laying of following size Heavy gauge PVC conduits concealed in wall/ ceiling/ floor/ column including supply and drawing of 12SWG GI wire as fish wire for laying of UPS/ raw power cables at a later stage and supply of all fixing materials complete as required.

Supply and laying of 1.6mm Thick Aluminum Floor Raceways of the following sizes in the floor including cutting the floor with cutting machine etc wherever required and finishing to normal level as required (and the debrise shall be shift outside the premises - as directed by the site engineer). Earth wire of 12SWG size GI wire shall be run all along the raceways for body earthing.

Supply and fixing of Raceway Junction boxes made out of 2mm thick MS sheet including powder coating as required fixed in floor. The box shall be provided with removable type 3mm thick powder coated cover.

Page 32: Electrical BOQ R0!31!08-2013

For Employer Page 32 of 54 For Contractor

Project : Expansion of Yashoda Hospital- Phase-1

Client:Yashoda Hospitals

Architect: SMJ Design Inc

PMC: KP Management Associates

MEP Consultant: Synergy Infra Consultant Pvt Ltd BOQ

Interior Consultant: M/s. Prasad Badle Architects

Location: Somajiguda-Hyderabad Date: 31-Aug-2013 Rev: R0

S.No DESCRIPTION UNIT QTY RATE AMOUNT

Supply Installation Supply Installation

Package: Supply,Installation,Testing and Commissioning of External and Internal Electrification

44.1 450mm wide Mtrs 8504.2 300mm wide Mtrs 9004.3 150mm wide Mtrs 450

SUB TOTAL FOR INTERNAL ELECTRIFICATIONGRAND TOTAL FOR ELECTRIFICATION SYSTEM

Supply, fabrication, erection and commissioning of GI Perforated type Cable trays made out of 2mm thick GI sheet and supported with 10mm dia rods from ceiling using anchor fasteners

Page 33: Electrical BOQ R0!31!08-2013

FIRE FIGHTING WORKS

SYNERGY infra CONSULTANTS PVT.LTD 1

S.NO DESCRIPTION UNIT QTY Supply Instalation1

Rmt 15 6200 300

2

a) )750mm wide x 400mm deep x 600mm Nos 15 3400 200

3

Nos 30 3000 200

4 Nos 15 2000 100

5

Nos 14 6300 300

6 1200

a) 25 mm dia Nos 14 1200 100

7

Nos 15 1200 200

8

a) 150mm dia Rmt 175 1150 450

b) 100mm dia Rmt 75 900 300

c) 80mm dia Rmt 50 750 250

d) 50mm dia Rmt 75 400 150

e) 25mm dia Rmt 50 275 75

9

17500

a) 100mm dia Nos 1 17500 500

Providing and fixing 63 mm dia (2.1/2”) N.B. hydrant Single headed oblique landing Valve in SS Morris Pattern instanteous coupling type ISI certified heavy type hydraulically tested to 250 psi working pressure with necessary nuts, bolts Gaskets, GI chain twist release type plug. including fabricated tee connection, as per IS 5290

Supplying & fixing fire hydrant MS cabinet type shutter enclosure of following size made up of 16 guage MS plate continuously welded on all edges or fabricated with bends at all edges using single plate capable of accommodating the 2 nos. 15 m fire hose And 1 nos.SS branch pipe. Including railway coach lock up arrangement & lever for opening the door after breaking the glass. Each hose box is to be fitted with front glass door painted "FIRE" with red luminous paint. Hinges should be sturdy to bear the weight of fully open door without sagging. Cabinet should be powder coated by standard process on all sides with red paint of approved make suitable for fixing to wall as directed by Architect (flush/surface mounted) etc. complete. Contractor to get sample approved for workmanship from Architect.

Supplying and fixing 63mm dia Hose pipe Reinforced Rubber lined as per IS:636 type-A respectively with 15 M standard length including SS metal male and female Coupling duely bound with GI wire,etc. Complete As directed by Architect in charge.

Supply and fixing of S.S. branch pipe with 63mm dia female inlet and male threaded outlet with hexagonal based nozzle as per IS 903Supplying & fixing first aid fire hosereel of Synthetic rubber suitably reinforced Dunlop/NEWAGE/EQV make 20mm /25 MMsize & 30m standard length with PVC nozzle with cut off valve attachment. Hose to be swinging type wall mounted drum & recessing into hose cabinet to suit location including fixing with lead anchor fasteners & bolts ( Incluiding drum and swivel arrangment ) etc complete.

Providing and fixing ball VALVE heavy quality fullway valves for isolation at inlet to hose reels (ISI certified make) etc. complete.

Supplying and fixing specially designed SS orifice plates on hydrant outlets of landing valves including distant pieces of suitable size for adjustment of delivery pressure of 3.5 kg/ sq.cm as required by LPA complete with necessary companion flanges, nuts, bolts, gaskets etc. complete.

Supplying, installation testing and commissioning of the following (Class 'B') MS pipes and fittings confirming to IS 1239 PI & II, with flanges welded /welded joints) as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, specials like sockets, union nuts, elbows, reducers, plugs, Tees etc.Complete to make the system operative as required by local fire authorities. including welding, cutting, fixing in / on walls, under ground etc., the pipes will have to be laid and fixed in trenches on walls, ceilings, into brick walls or RCC with lead anchor fastners.The work includes excavation in all types of soils and back filling and making holes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the Architect and painting two coats of approved shade of enamel paint over a coat of approved primer.

Supplying, installation testing and commissioning Cast Iron Body Sluice valve PN 1.6 Non-rising stem type conforming to IS:780, with flanged ends

Page 34: Electrical BOQ R0!31!08-2013

FIRE FIGHTING WORKS

SYNERGY infra CONSULTANTS PVT.LTD 2

S.NO DESCRIPTION UNIT QTY Supply Instalation10

a) 100mm dia Nos 1 17500 500

11

a) 150mm dia Nos 2 7000 500

12 Nos 2 2300 200

13

a)80mm dia Nos 14 5300 200

14

a) 3C x 1.5.sqmm Rmt 2500 55 10

15 NOS 1 24000 1000

TOTAL RATE

II FIRE HYDRANT INSTALLATION (EXTERNAL)

1

Nos 6 6300 200

2

a) )750mm wide x 250mm deep x 600mm Nos 6 3400 200

3

Nos 12 3000 200

4 Nos 6 2000 100

Supplying, installation testing and commissioning C.I. Non-return valve conforming to IS : 5312 with flanged ends (heavy) tested to 250 psi hydraulic pressure with necessary companion flanges, bolts, nuts, gasket packing and any other spares, including indicator for open ands hut position as per fire practice etc complete.

Supply and installation of CI Butterfly valves (heavy) tested to 250 psi hydraulic pressure with Vertical/horizontal gear unit with appropriate handle conforming to IS:13039 with necessary companion flanges, neoprene gaskets with necessary companion flanges, bolts, nuts, gasket packing and any other spares, including indicator for open and Shut position as per fire practice etc complete.

Supply, installation, testing & commissioning of Gun metal Air release valve with ball valve - 25mm dia

Supply installation and fixing of flow switches in the following Pipe line with 1NO+1NC Contacts

Supply and installation, and fixing of 1.1KV PVC XLPE insulated cables of copper conductor with double compression type cable gland and heavy duty tinned copper cable sockets as per the relevant IS standards. Rate shall be inclusive of all sundry materials like adhesive tape , PVC sleeves , bolts and nuts, washers etc. including plugging unused holes.

Supply, installation, testing & commissioning of 16 WINDOW ANNUNCIATION PANEL FOR FIRE INDICATION from flow switch

Providing and fixing 63 mm dia (2.1/2”) N.B. hydrant single headed oblique landing Valve in SS Morris Pattern instanteous coupling type ISI certified heavy type hydraulically tested to 250 psi working pressure with necessary nuts, bolts Gaskets, GI chain twist release type plug. including fabricated tee connection, as per IS 908

Supplying & fixing fire hydrant MS cabinet type shutter enclosure of following size made up of 16 guage MS plate continuously welded on all edges or fabricated with bends at all edges using single plate capable of accomodating the 2 nos. 15 m fire hose And 1 nos SS branch pipe. Including railway coach lock up arrangement & lever for opening the door after breaking the glass. Each hose box is to be fitted with front glass door painted "FIRE" with red luminous paint. Hinges should be sturdy to bear the weight of fully open door without sagging. Cabinet should be powder coated by standard process on all sides with red paint of approved make suitable for fixing to wall as directed by Architect (flush/surface mounted) etc. complete. Contractor to get sample approved for workmanship from Architect.

Supplying and fixing 63mm dia Hose pipe Reinforced Rubber lined as per IS:636 Part-A respectively with 15 M standard length including SS metal male and female Coupling duely bound with GI wire,etc. Complete As directed by Architect in charge.

Supply and fixing of S.S. branch pipe with 63mm dia female inlet and male threaded outlet with hexagonal based nozzle as per IS 903

Page 35: Electrical BOQ R0!31!08-2013

FIRE FIGHTING WORKS

SYNERGY infra CONSULTANTS PVT.LTD 3

S.NO DESCRIPTION UNIT QTY Supply Instalation5

Nos 6 1200 200

6

a) 150mm dia Rmt 150 1150 450

b) 100mm dia Rmt 35 900 300

c) 80mm dia Rmt 15 750 250

7

Nos 1 21500 500

8

Nos 1 27500 500

9

Nos 3 12500 1500

10

a) 150mm dia Nos 3 21500 500

11

Supplying and fixing specially designed SS orifice plates on hydrant outlets of landing valves including distant pieces of suitable size for adjustment of delivery pressure of 3.5 kg/ sq.cm as required by LPA complete with necessary companion flanges, nuts, bolts, gaskets etc. complete.

Supplying, installation testing and commissioning of the following (Class 'B') MS pipes and fittings confirming to IS 1239 PI & II, with flanges welded /welded joints) as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, specials like sockets, union nuts, elbows, reducers, plugs, Tees etc.Complete to make the system operative as required by local fire authorities. including welding, cutting, fixing in / on walls, under ground etc., Underground piping with necessary flanges & fittings such as elbows,tees and providing and fixing anchor blocks in PCC 1:2:4 at all bends, tees, alongwith pipe coating and wrapping of underground pipes with `PYPKOTE' 4mm thick conforming to IS : 10221. It includes providing and fixing pypkote (corrosion protection tape) including supply and application of pipe coating and spiral Wrapping (wrapping should have overlap of 15 to 20 mm) etc. complete as per ASTM standards for corrosion protection of pipes that will be laid under the ground]

Supplying, installing and commissioning of fire brigade inlet connection conforming to IS 5290 comprising of 2nos.SS 63mm dia instantaneous couplings complete with CI non-return valve, CI butterfly valve, connected to 150 mm dia Fire TANK FILLINGand fire hydrant wet riser pipe.

Supplying, installing and commissioning of fire brigade inlet connection conforming to IS 5290 comprising of 4nos.SS 63mm dia instantaneous couplings complete with CI non-return valve, CI butterfly valve, connected to 150 mm dia forRING MAIN

Constructing masonry Chamber 1200x1200x1000 mm, inside with 75 class designation brick work in cement mortar 1:6 ( 1 cement : 6 fine sand ) for sluice valve, with C.I.surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12mm thick finished with a floating coat of neat cement complete as per standard design including curing, back filling of the chamber sides with the excavated soil, disposing of the surplus earth after back filling with initial lead of 30 meters. Providing medium duty cast iron frame and cover etc., complete. ( weight: 110kgs.) as per specification.

Supply, installation, testing & commissioning of Cast Iron Body Sluice valve PN 1.6 Non-rising stem type conforming to IS:14846, with flanged ends

Supply, installation, testing & commissioning of R.C.C NP2 class Hume pipe laid to the required level and grade with collars jointed with in CM1:3. Including encasing the pipe around a depth of not less than 15cm thick with selected earth (fine aggregate) available from the excavation as per specification and direction of the engineer. The excavated soil shall be deposited on banks with all lead, lift, including necessary wooden/steel form work where ever required. Depositing of the surplus earth after backfilling to a initial lead of 30 meters. Refilling of the pipe line trenches and foundation with selected earth available from the trench excavation including watering consolidation in layers of 15cm thickness complete as per specifications. The back fill soil shall be graded soil free from stones, pebbles, clay lumps and vegetation etc., complete as per the specifications, and drawings.

Page 36: Electrical BOQ R0!31!08-2013

FIRE FIGHTING WORKS

SYNERGY infra CONSULTANTS PVT.LTD 4

S.NO DESCRIPTION UNIT QTY Supply Instalationa) 300mm dia Rmt 20 1200 200

12 Nos 3 2300 200

13

a) 150mm dia Nos 3 7000 500

TOTAL RATE

III FIRE PUMP HOUSE

1

Nos 2 15000

2

Nos 1 455000 20000

3

Nos 1 95000 5000

4

RO 1 45000 5000

Supply, installation, testing & commissioning of Gun metal Air release valve with ball valve - 25mm dia

Supply and installation of CI Butterfly valves (heavy) tested to 250 psi hydraulic pressure with Vertical/horizontal gear unit with appropriate handle conforming to IS:13039 with necessary companion flanges, neoprene gaskets with necessary companion flanges, bolts, nuts, gasket packing and any other spares, including indicator for open and Shut position as per fire practice etc complete.

Supplying & installing completely testing & commissioning of electrically Driven End suction and back pull out pump with cast iron casing & bronze or phosphor bronze internal parts, for fire duty, complete with coupling guard necessary RCC foundation,capable of discharging 2850 lt/min against 88 metre head at 8.8 bar against all losses complete electrically operated TEFC 3-ph, 440-V, 50 Hz, 2900 RPM motor of ‘F’ class winding, make as approved by TAC with automatic direct on line starter complete with single phasing preventor & No volt release as per LPA requirements common base plate, foundation bolts, suitable cable entry gland box for A-AL cable (95 sq.mm) pressure guages & wired for automatic start of the water pump on drop of pressure in the wet riser/ hydrant and sprinkler system. The motor starter and pump should confirm to LPA / BSES & and IE Regulations. The pump shall be capable of giving not less than 150% discharge at a head not less than 65% of the rated head.(Main Hydrant Pump and sprinkler)

Supplying & installation, testing & commissioning of End suction and back pull out diesel engine driven pump of capacity 2850 Litr/Min, 88 Mtrs head Common Standby pumpset for wetriser & sprinkler system at 8.8 Bar and 2900 rpm with all necessary accessories like bronze impeller, stainless steel shaft and mechanical seal along with anti-vibration mounting, coupling, gear box, base plate for pump, fabricated mild steel channel with foundation bolts etc., It includes providing and fixing fuel oil tank (capacity as perTAC requirements) with supports and necessary pipe works for diesel engine, battery and battery charger to be connected to control panel of diesel engine and exhaust silencer including necessary pipe work insulation and cladding, etc., and shall be automatic in operation with diesel engine control diesel engine control panel with 24V DC storage battery & its battery charger. (diesel engine)

Supplying, installing, testing and commissioning of electrical motor Driven jockey pump for hydrant system with discharge 180 lpm against head 88 mtrs at 8.8 bar with M.S. frame and clamps as necessary for fixing the pumps on the foundation slab as per site conditions

Supplying, installing, testing and commissioning of electrical motor Driven Booster pump for hydrant system with discharge 900 lpm against head 35 m with M.S. frame and clamps as necessary for fixing the pumps on tthe foundation of slab as per site conditions

Page 37: Electrical BOQ R0!31!08-2013

FIRE FIGHTING WORKS

SYNERGY infra CONSULTANTS PVT.LTD 5

S.NO DESCRIPTION UNIT QTY Supply Instalation5

Incoming – 400A,50KA FP MCCB -1set(with Mechanical interlocking between incommers and Bus couplers)Busbars : 400A TPN aluminium BUSBARS- 1SET

(2) DOL starter same as above for 15HP motor - 1set

(3) 63A , TPN MCCB for terrace booster pump - 1 Set

(4) 32A, TPN MCB feeder for Engine control panel-1 Set

Nos 1 220000 5000

6

RO 1 13000 2000

7

Supply, Installation, Testing and Commissioning of Indoor / outdoor, weatherproof 3 phase 415V 4 wire Free Standing Floor mounted MV panel made out of 14 SWG CRCA sheet after seven tank process and painting with Epoxy powder coating including all switchgear as detailed below. The panel shall consist of suitable rating TPN Aluminium/Copper busbar (at the rating of 0.8A/Sq.mm/1.6A/sq.mm) supported with DMC/ SMC barriers and colour coded with Heat shrinkable sleeves.The Metering shall be provided as specified. The panel shall have Short circuit with standing capacity of minimum 50KA and consist of the switchgear as mentioned below. The panel shall be mounted on channels grouted to the existing floor including all materials. The panel shall be got fabricated from manufacturers with CPRI Test certificate only. All the PCC/ Panels shall have at least two spare cubicles of the maximum rating. All feeders shall be earthed with 2 GI flats of adequate size to the main earth bus of 50x6mm GI flat. The size of all Panel Mounting Meters shall be 96X96mm.The Panels shall be mounted on U channels including supply and fixing of the same.All MCCBs shall have 80-100% thermal setting plug. MCBs shall be provided for Control purposes.

Supply, installation, testing and commissioning of electrical control panel diesel engine main motor and jockey pump, comprising of following. All contactors shall have status feed back provision to BMS.

Outgoings : (1) DOL starter with MCCB and contactor, over load relay,single phasing preventor and ON/OFF/TRIPindication lamps for motor -2sets

Metering ; Voltmeter, Ammeter, LED phase Indication lamps, Ammeters for both outgoings The Rate shall include supply and fixing of all The Rate shall include supply and fixing control devices for auto operation of pump of all motors

Supply, installation, testing and commissioning of weather proof type starter consisting of following and made of 2mm thick CRCA sheet including painting with epoxy powder coating for 15HP Booster pump motor. The box shall be suitable for terminating AYFY cable of 3core 6sq.mm size. The box shall be mounted on suitable angle frame work of 450mm height on a PCC pedestal including all materials. The stater shall have status feed back provision to BMS

DOL starter suitable for 15HP with MPCB and contactor, over load relay, single phasing preventor and ON/OFF/TRIP indication A/M selection switch & push button for manual operations and with volt meter,Ammeter with selector switches

Supplying, installation testing and commissioning of the following (Class 'B') MS pipes and fittings confirming to IS 1239 PI & II. The pipes complete with necessary specials such as tees, bends, flanges, reducers, etc. Rate quoted shall include for painting of pipe with a coat of primer and two coats of synthetic enamel paint of approved colour / make for aboveground piping and coating & wrapping for under ground piping as per the TAC / IS standards and Local fire service department requirement complete including supply and installation of pipe supports, fasteners etc.,

Above ground piping with necessary flanges & fittings such as elbows, tees and Painting, supports and Orifice plates if any necessary for the fire protection system complete as per the requirement of Local fire service department.

Page 38: Electrical BOQ R0!31!08-2013

FIRE FIGHTING WORKS

SYNERGY infra CONSULTANTS PVT.LTD 6

S.NO DESCRIPTION UNIT QTY Supply Instalationa) 200mm dia Rmt 30 1400 600

b) 150mm dia Rmt 20 1150 450

c) 100 mm dia Rmt 15 900 300

d) 80 mm dia Rmt 15 750 250

e) 50 mm dia Rmt 25 400 150

f) 25 mm dia Rmt 30 275 75

8

a) 200mm dia Nos 4 27500 500

b) 150 mm dia Nos 4 21500 500

c) 100mm dia Nos 1 17500 500

d) 80mm dia Nos 1 14500 500

9

a) 200mm dia Nos 1 27500 500

b) 150mm dia Nos 3 21500 500

c) 80mm dia Nos 1 17500 500

10

a) 200mm dia Nos 3 31500 500

b) 100mm dia Nos 1 17500 500

11

a) 25 mm dia Nos 5 2400 100

12

a) 25mm dia Nos 5 2400 100

13

Nos 1 12500 1500

14Nos 10 2200 100

15 Nos 5 4500 200

16 Supply fabrication and erection of MS angle supports for Pipe lines Ton 1 60000 5000

17

a) 3C x 120.sqmm AYFY cable ( to main pump ) Rmt 60

b) 4C x .16sqmm AYFY cable ( for jockey pump & booster pumps) Rmt 25

c) 3C x 1.5.sqmm copper control cable ( To Pressure switches controllers) Rmt 75

Supplying, installation testing and commissioning Cast Iron Body Sluice valve PN 1.6 Non-rising stem type conforming to IS:780, with flanged ends

Supplying, installation testing and commissioning C.I. Non-return valve conforming to IS : 5312 with flanged ends (heavy) tested to 250 psi hydraulic pressure with necessary companion flanges, bolts, nuts, gasket packing and any other spares, including indicator for open ands hut position as per fire practice etc complete.

Supplying, installation testing and commissioning Foot valve/strainer with Flanged ends.

Supplying, installation testing and commissioning of G.M. gate valves conforming to IS 778

Supplying, installation testing and commissioning of G.M. Non-return valves conforming to IS 778

Supplying and fixing MS fabricated air vessel at pump room about 250mm dia and 1500mm high on MS stand with necessary cut off drain and air release arrangements and leading the drain pipe to the sump at pump room with painting with red oxide primer and finished with fire red enamel paint. It shall be inclusive of all relevant pipes, valves, specials upto pump header and other accessories as per Local fire service department standard / requirement. including TAC approved pressure gauge with cork and of suitable range as for Providing required pressure etc. complete.

Supplying, installation testing and commissioning of Pressure gauge (0-14 Kg./sqcm) of 100 mm dia Dial size with required fittings and accessories

Supplying, installation testing and commissioning of Pressure switch (0-15 Kg./sqcm) with required fittings and accessories

Supplying, installation testing and commissioning of End termination for 1.1KV cables with double compression type cable gland and heavy duty tinned copper cable sockets as per the relevant IS standards. Rate shall be inclusive of all sundry materials like adhesive tape , PVC sleeves , bolts and nuts, washers etc. including plugging unused holes.

Page 39: Electrical BOQ R0!31!08-2013

FIRE FIGHTING WORKS

SYNERGY infra CONSULTANTS PVT.LTD 7

S.NO DESCRIPTION UNIT QTY Supply Instalation18

a) 150mm dia Set 1

19

a)300mmX50mm Rmt 60

20

a)50X6mm GI strip Rmt 30b)25X3mm GI strip Rmt 30c) 8SWG GI Wire Rmt 10

21

Nos 1

TOTAL

IV AUTOMATIC SPRINKLER SYSTEM.

1

Nos 700

2

Nos 100

3 Nos 250

4

a) 100mm dia Nos 10

b) 80mm dia Nos 4

c) 50mm dia Nos 4

5

a) 150 mm dia

Supply, fixing, testing and commissioning & installation of alarm gong valve assemble contains of 1-no. Alarm valve, 1 no. Main stop valve, 1 no. water meter with alarm gong, Pressure guage drain valve and drain piping etc.,

Supply and installation of GI Perforated cable trays of following sizes made out of 2mm thick GI sheet including all supports as required

Supply and laying of following size hot dip galvanized GI strips to run along with cable trays for erathing of all motors

Supplying, installation testing and commissioning priming HDPE tank (Sintex) of 500Ltrs capacity at required level including MS angle supports, with inlet,outlet,overflow & drain pipes including controlling valves,welding of supports bolts and nuts etc., complete accessories

Supply and installation, Providing and fixing approved make 15mm orifice quartzoid bulb type sprinklers, 68°C rating, recessed pendent type with roset plate (adjustable) off white finish wherever required and all accessories, supports and painting etc.

Supply and installation, Providing and fixing approved make 15mm orifice quartzoid bulb type sprinklers, 68°C rating, recessed wall mounted type with roset plate (SINGLE ) off white finish wherever required and all accessories, supports and painting etc.

Supply and installation, testing and commissioning of Sprinkler flexible Pipe required length of 1.5M including angles and supports Supply and installation of CI Butterfly valves (heavy) tested to 250 psi hydraulic pressure with Vertical/horizontal gear unit with appropriate handle conforming to IS:13039 with necessary companion flanges, neoprene gaskets with necessary companion flanges, bolts, nuts, gasket packing and any other spares, including indicator for open ands hut position as per fire practice etc complete.

Supplying, installation testing and commissioning of the following (Class 'B') MS pipes and fittings confirming to IS 1239 PI & II, The pipes complete with necessary specials such as tees, bends, flanges, reducers, etc. Rate quoted shall include for painting of pipe with a coat of primer and two coats of synthetic enamel paint of approved colour / make for aboveground piping and coating & wrapping for under ground piping as per the TAC / IS standards and Local fire service department requirement complete including supply and installation of pipe supports from column/wall or suspenders from roof slab to suit various dia of pipes made out of GI adjustable rods threaded for a sufficient length to adjust the height of support along with clamping arrangement for holding pipes of anchor fastening arrangement design of hanger and should confirm to specification as indicated NFPA 13. etc.,

Above ground piping with necessary flanges & fittings such as elbows, tees and Painting, supports and Orifice plates if any necessary for the fire protection system complete as per the requirement of Local fire service department.

Page 40: Electrical BOQ R0!31!08-2013

FIRE FIGHTING WORKS

SYNERGY infra CONSULTANTS PVT.LTD 8

S.NO DESCRIPTION UNIT QTY Supply InstalationSupply Rmt

installation Rmt

b) 100mm diaSupply Rmt

installation Rmt

c) 80mm diaSupply Rmt

installation Rmt

d) 65mm diaSupply Rmt

installation Rmt

e) 50 mm diaSupply Rmt

installation Rmt

f) 40 mm dia.Supply Rmt

installation Rmt

g) 32 mm diaSupply Rmt

installation Rmt

h) 25 mm diaSupply Rmt

installation Rmt

6

a)50 mm dia Rmt 60

b)40 mm dia Rmt 30

c)25 mm dia Rmt 120

7

a)100mm dia Nos 10b)80mm dia Nos 4

8

a) 50 mm dia No 14

a) 25 mm dia No 4

9

a) 3C x 1.5.sqmm Rmt 2500

10 NOS 1

TOTALV WATER CURTAIN SYSTEM.

Supplying, installation testing and commissioning of the CPVC pipes as per IS:16088Above ground piping with necessary flanges & fittings such as elbows, tees and supports and Orifice plates if any necessary for the fire protection system complete as per the requirement of Local fire service department.

Supply installation and fixing of flow switches in the following Pipe line with 1NO+1NC Contacts

Supplying, fixing and testing approved make gun metal ball valve conforming to IS 778 with unions etc., complete as per specifications.

Supply and installation, and fixing of 1.1KV PVC XLPE insulated cables of copper conductor with double compression type cable gland and heavy duty tinned copper cable sockets as per the relevant IS standards. Rate shall be inclusive of all sundry materials like adhesive tape , PVC sleeves , bolts and nuts, washers etc. including plugging unused holes.

Supply, installation, testing & commissioning of 16 WINDOW ANNUNCIATION PANEL FOR FIRE INDICATION from flow switch

Page 41: Electrical BOQ R0!31!08-2013

FIRE FIGHTING WORKS

SYNERGY infra CONSULTANTS PVT.LTD 9

S.NO DESCRIPTION UNIT QTY Supply Instalation1

a) 80mm dia Rmt 300

2

a) 80mm dia Nos 5

3

Nos 5

4 Nos 120

5

Rmt 1500

TOTAL

Supplying, installation testing and commissioning of the following (Class 'C') GI pipes and fittings confirming to IS 1239 PI & II, for water curtain system . The pipes complete with necessary specials such as tees, bends, flanges, reducers, etc. Rate quoted shall include for painting of pipe with a coat of primer and two coats of synthetic enamel paint of approved colour / make for aboveground piping and coating & wrapping for under ground piping as per the TAC / IS standards and Local fire service department requirement complete including supply and installation of pipe supports from column/wall or suspenders from roof slab to suit various dia of pipes made out of GI adjustable rods threaded for a sufficient length to adjust the height of support along with clamping arrangement for holding pipes of anchor fastening arrangement design of hanger and should confirm to specification as indicated NFPA 13. etc.,

Above ground piping with necessary flanges & fittings such as elbows, tees and Painting, supports and Orifice plates if any necessary for the fire protection system complete as per the requirement of Local fire service department.

Supply,installation,testing and commissioning of Motorized Butterfly valve with actuator for Water curtains with electrical motors suitable for 220V, Single Phase 50Hz AC supply operation

Supply and installation, of control panel for water curtain motor consisting of suitable relay MPCB ,DOL starter with contactor , over load relay, auto/manual switch ,push buttons in manual mode and ON/OFF trip indicators all prewired

Supply,installation,testing and commissioning of 15mm Dia open type water curtain nozzles with k-factor of 25-32.Supplying, installation testing and commissioning of End termination for 1.1KV cables with double compression type cable gland and heavy duty tinned copper cable sockets as per the relevant IS standards. Rate shall be inclusive of all sundry materials like adhesive tape , PVC sleeves , bolts and nuts, washers etc. including plugging unused holes.

c) 3C x 2.5.sqmm copper control cable ( To motorized butterfly valve to panel)

Page 42: Electrical BOQ R0!31!08-2013

FIRE FIGHTING WORKS

SYNERGY infra CONSULTANTS PVT.LTD 10

S.NO DESCRIPTION UNIT QTY Supply Instalation

VI ADDRESSABLE FIRE ALARM SYSTEM

1

1.1 6 Loop fire alarm panel (with each loop supporting 125 Detectors & Devices). No 1

2 Mtr 4500

3 No 325

4 No 325

5 No 325

6 No 18

7 No 18

9 Supply and fixing of Exit Light fixtures with 1.5hrs battery backup No 22

10 No 30

11 No 20

12 Supply and fixing of duct detectors for AHU's at different levels. No 20

13 No 1

14

c) Establishing two way communication with master panel and slave panels. No 1

15 RO 1

TOTAL

VII PUBLIC ADDRESS SYSTEMS.NO DESCRIPTION

Supply, fixing, testing and commissioning of the following number of Loops Microprocessor based analogue addressable type Fire Control panel with Zonal Indications , The system should have BMS compatibility, The system shall have a built-in relay & Hooter to initiate failure of FACP.

Supply testing and laying of PVC insulated, 1.5sq.mm shielded armoured twisted pair copper cable including all fixing accessories when laid inside the building including complete with end terminations at both sides.

Supply installation testing and commissioning of analogue addressable type Multi (smoke& Heat ) photo electric detectors with LED indication lamp and with in built fault isolator.(Below false ceiling) with complete fixing accessories.

Supply installation testing and commissioning of analogue addressable type Multi (smoke& Heat ) photo electric detectors with LED indication lamp and with in built fault isolator.(Above false ceiling) with complete fixing accessories.

Supply installation testing and commissioning of response indicators with all fixing accessories Supply installation testing and commissioning of Loop sounders with all fixing materials. Supply and installation of analogue addressable type Manual call points with Glass, hammer and monitor module and fixing accessories

Supply installation testing and commissioning of analogue addressable type monitor modules for monitoring the sprinkler flow switches

Supply installation testing and commissioning of analogue addressable type control relay / control modules for AHUS, Electrical circuit tripping, and PA amplifier activation in case of fire alarm.

Supply, installation, testing and commissioning of intelligent Addressable network control Active Repeater panel on FACP network configuration to monitor and control all local fire alarm control panels with RS 485 port on CPU board with optional network software connectivity, fire/ fault indicators, audio visual signals, battery, battery charger, central processing unit 80 character display unit complete in all respects.

Supply, installation, testing and commissioning of Fire alarm management software system and graphical display interface to network the installed fire alarm panels using a network manager program and the following shall be pre-equipped with :

a) Preparation of graphics compatible to fire alarm monitoring software of buildings and connected with slave panels including layout of the building and wiring diagram of the fire alarm system

b) Interconnecting the same with fire alarm software located at master panel testing the parameters and operations of individual detectors and slave panels

A server based PC with 21” LCD monitor with 4 GB RAM loaded, 500GB HDD , with per-loaded software's shall include UPS with 15 min backup and along with all fixing accessories. ( The above said item shall be in client scope )

Page 43: Electrical BOQ R0!31!08-2013

FIRE FIGHTING WORKS

SYNERGY infra CONSULTANTS PVT.LTD 11

S.NO DESCRIPTION UNIT QTY Supply Instalation1

Nos 45

3 Mtr 3000

4 Mtr 3500

5 Nos 1

6 Nos 1

TOTALVIII FIRE EXTINGUISHERS1

Nos 78

2

Nos 78

3

Nos 10

4 Nos 18

5

Sq.ft 50 0

21943TOTAL Rs.

Supply and installation testing and commissioning of 6Watt 180mm dia recessed/ surface mounted white color speakers (along with junction boxes to be used in no false ceiling area).

Supply and surface laying of 25mm dia heavy guage PVC conduits including all fixing accessories like saddles etc ( Shall be on actuals ).Supply and laying of shielded twin twisted pair 1.0 sqmm cable in existing conduit ( Shall be on actuals ).Supply installation testing and commissioning of 480 watts amplifiers complete with accessoriesSupply installation and testing of GOOSE NECK MICROPHONE for announcement purpose.

Supply installation testing and commissioning of Water CO2 type Fire Extinguisher of 9lit capacity, fitted with discharge control valve ( squeeze grip type ) , inside STORED PRESSURE with ISI mark, with discharge hase and open nozzel overall conforming to IS: 15683 with ISI mark along with wall bracket and initial refilling at site . Fire Rating 2A.

Supply installation testing and commissioning of CO2 type Fire Extinguisher of 4.5 kgs capacity made from brand new seamless drawn steel cylinder as per IS : 7285 with ISI mark and Chief of controller of explosives approval, fitted with wheel valve as per IS: 3224 with ISI mark, with discharge hose and horn and supplied complete with initial charge overall conforming to IS: 15683 with ISI mark and wall bracket. Fire Rating 21B

Supply installation testing and commissioning of ABC Dry Chemical Powder 6.0 kg capacity fitted with discharge control valve ( squeeze grip type ), inside STORED PRESSURE with ISI mark and ABC powder as per IS: 14609 ( for ABC class ) with ISI mark packed in 6kgs HDPE bags, with discharge hose and open nozzel and supplied complete with initial charge overall conforming to ISI: 15683 ISI mark and wall bracket . Fire Rating 3A.34B.

Supply installation testing and commissioning of Clean Agent Fire Extinguishers, 2.0 kg capacitySealing of Fire shafts at all floor levels by using M.S. angle Iron frame around the shaft M.S. chequered plate and PCC of 1:2:4 (100mm thick) on the plate for whole shaft area as per drawings and engineer- in - charge.

Page 44: Electrical BOQ R0!31!08-2013

FIRE FIGHTING WORKS

SYNERGY infra CONSULTANTS PVT.LTD 12

AMOUNT

Page 45: Electrical BOQ R0!31!08-2013

FIRE FIGHTING WORKS

SYNERGY infra CONSULTANTS PVT.LTD 13

AMOUNT

Page 46: Electrical BOQ R0!31!08-2013

FIRE FIGHTING WORKS

SYNERGY infra CONSULTANTS PVT.LTD 14

AMOUNT

Page 47: Electrical BOQ R0!31!08-2013

FIRE FIGHTING WORKS

SYNERGY infra CONSULTANTS PVT.LTD 15

AMOUNT

Page 48: Electrical BOQ R0!31!08-2013

FIRE FIGHTING WORKS

SYNERGY infra CONSULTANTS PVT.LTD 16

AMOUNT

Page 49: Electrical BOQ R0!31!08-2013

FIRE FIGHTING WORKS

SYNERGY infra CONSULTANTS PVT.LTD 17

AMOUNT

Page 50: Electrical BOQ R0!31!08-2013

FIRE FIGHTING WORKS

SYNERGY infra CONSULTANTS PVT.LTD 18

AMOUNT

Page 51: Electrical BOQ R0!31!08-2013

FIRE FIGHTING WORKS

SYNERGY infra CONSULTANTS PVT.LTD 19

AMOUNT

Page 52: Electrical BOQ R0!31!08-2013

FIRE FIGHTING WORKS

SYNERGY infra CONSULTANTS PVT.LTD 20

AMOUNT

Page 53: Electrical BOQ R0!31!08-2013

FIRE FIGHTING WORKS

SYNERGY infra CONSULTANTS PVT.LTD 21

AMOUNT

AMOUNT

Page 54: Electrical BOQ R0!31!08-2013

FIRE FIGHTING WORKS

SYNERGY infra CONSULTANTS PVT.LTD 22

AMOUNT