Electrical BOQ
-
Upload
sajeewa-lakmal -
Category
Documents
-
view
578 -
download
48
Embed Size (px)
description
Transcript of Electrical BOQ

PROJECT NAME
08
ITEM DESCRIPTIONQTY. UNIT UNIT RATE
ITEMREF.
8F/- ELECTRICAL INSTALLATION
Note :
General
Inspection and testing
8F/01
1 Item 21,000.00
Main Power Supply System
cables
Note :
TO COLLECTION
BILL OF QUANTITIES
BILL NO.
SPEC. DIV. NO.
Proposed Housing Project for relocation of Under Served Settlements, Angulana
Block- D superstructure
All materials, equipments, wiring and workmanship shall confirm to local codes of specifications, B.S Standards, latest I.E.E regulations (17th edition) and Ceylon Electricity Board specifications. Contractor shall investigate the site conditions before submitting their quote
Contractor shall obtain sample approvals from all the items used from CEE-SEC
Contractor shall propose shop drawings/conduit layouts drawings and obtained approval from CEE-SEC before commencing installation
Testing of the complete Electrical Installation and issuing a certificate by a chartered Electrical Engineer, registered with Ceylon Electricity Board.
Rates should include for all necessary cable accessories such as cable ties, Cable Lugs, Glands, identification tags, and accessories All horizontal and vertical Cable trays should be adequately sized to provide 40% spare space.Contractor shall investigate the site conditions and include all the cost involved in point rates given below.
All the Cables quoted below shall be on measure and pay basis. Rates shall include installation of Cable taryas,Cable Ladders, PVC trunking or conduits and accessories where required .

PROJECT NAME
08
ITEM DESCRIPTIONQTY. UNIT UNIT RATE
ITEMREF.
8F/02
150 m 13,125.00
8F/03
80 m 3,675.00
8F/04
3600 m 1,470.00
8F/051350 m 265.00
Distribution Boards.
note
note
note
note
COMMON AREA
8F/06 Lift DB 1 no 68,250.00
01 No. 4P 63A MCB 01 No. DP 32A MCB 01 No. 4P 63A,100mA RCCB01 No. DP 40A,30mA RCCB01 No. SP 20A MCB02 Nos.SP 10A MCB01 No. SP 16A MCB
BILL OF QUANTITIES
BILL NO.
SPEC. DIV. NO.
Proposed Housing Project for relocation of Under Served Settlements, Angulana
Block- D superstructure
Supply,Installation & Termination of 4 x 70mm2 XLPE/SWA/PVC/Cu Cable from MSB to Meter Room 01 (For Block C)
Supply,Installation & Termination of 4 x 16mm2 PVC/PVC/Cu + 16mm2 PVC/Cu(E) Cable from G.SDB-2 to Lift DB
Supply,Installation & Termination of 2 x 6mm2 PVC/PVC/Cu Cable from Meter Room-2 to Each House Distribution Board
Supply,Installation & Termination of 6mm2 PVC/Cu Earth Cable from DB to Cu Plate at Electrical Shaft.
All Distribution Boards shall be flush/Surface mounted type Distribution Boards complete with powder coated 1.5 mm thick sheet steel enclosure with lockable doors.
The panel board should have wire numbering and a laminated circuit diagram pasted on the inside surface of the door.
Make of MCCBs and MCBs, etc shall be Merlin Gerin / ABB / Terasaki / Hager or equivalent make approved by the Electrical Engineer.
Manufactures soft drawings should be submitted and aproved by chief electrical engineer before fabrication.
Flush mounted Powder Coated Steel Lockable Enclosure c/w bus bars and Accessories

TO COLLECTION
PROJECT NAME
08
ITEM DESCRIPTIONQTY. UNIT UNIT RATE
ITEMREF.
HOUSES
8F/07 DB.H 45 no 26,250.00
01 No. 32A DP MCB01 No. DP 40A,30mA RCCB01 No.SP 16A MCB09 Nos.SP 20A MCB
Wiring for light points, ceiling fans, socket outlets
note
note
COMMON AREA
8F/08
72 no 2,890.00
HOUSES
8F/09
360 no 2,890.00
8F/10
45 no 3,340.00
BILL OF QUANTITIES
BILL NO.
SPEC. DIV. NO.
Proposed Housing Project for relocation of Under Served Settlements, Angulana
Block- D superstructure
Flush mounted Powder Coated Steel Lockable Enclosure c/w bus bars and Accessories
Rate point wiring shall include for all the conduits, conduit fittings, casings,surface cable trunks, fixing material, switches, wiring and terminations, holders for light fittings and socket outlets for power points. Contractor shall obtain approvals from the Chief Electrical Engineer for above items. Aproved samples should be displayed at the site office.
As a standard of quality for switches and socket outlets, the contractor may use 'CLIPSAL/hager /mk or approved equal'.
Supply and Installation a light point, from the respective consumer unit using 2x1mm2 PVC/PVC/CU + 1.5mm2 PVC/cu(E) cable drawn through securely fixed concealed PVC conduit controlled by a 5A flush switch as shown in the drawings.
Supply and Installation a light point, from the respective consumer unit using 2x1mm2 PVC/PVC/CU cable drawn through securely fixed concealed PVC conduit controlled by a 5A flush switch as shown in the drawings.
Supply and Installation a Bell point, from the respective consumer unit using 2x1mm2 PVC/PVC/CU cable drawn through securely fixed concealed PVC conduit controlled by a Bell push as shown in the drawings.

TO COLLECTION
PROJECT NAME
08
ITEM DESCRIPTIONQTY. UNIT UNIT RATE
ITEMREF.
8F/11
270 no 3,150.00
8F/12
45 no 4,725.00
Light fittings
note
note
note
note
COMMON AREA
8F/13 Bulk Head Lamp- Type A 72 no 3,675.00
HOUSES
8F/14 Bracket Lamp c/w 70W CFL 45 no 3,675.00
8F/15 Pendent Lamp c/w 70W CFL 270 no 2,625.00
8F/1645 no 2,940.00
8F/17 Electrical Bell With Bell Push 45 no 3,675.00
8F/18 Provisional Sum for Lightning Protection System Item
8F/19 Provisional Sum for Telephone and TV Wiring System Item
TO COLLECTION
BILL OF QUANTITIES
BILL NO.
SPEC. DIV. NO.
Proposed Housing Project for relocation of Under Served Settlements, Angulana
Block- D superstructure
Supply and Installation a 5A single switched socket outlet fixed on wall, from the respective consumer unit using 2x1.5mm2 PVC/PVC/CU + 1.5mm2PVC/cu(E) cable drawn through securely fixed concealed PVC conduit shown in the drawings.
Supply and Installation a 15A single switched socket outlet fixed on wall, from the respective consumer unit using 2x2.5mm2 PVC/PVC/CU + 2.5mm2PVC/cu(E) cable drawn through securely fixed concealed PVC conduit shown in the drawings.
The light fittings supplied and installed under this contract shall be in every respect suitable for the intended purpose.
Each fitting shall include bulbs, internal wiring, hanging and fixing material and be complete without any additional item/material being required to make it so.
All control gear of light fittings such as choke, starters, PF Correction Capacitors shall be of European make
The contractor shall obtain consultants and clients approval for the fittings before fixing the fittings in the site
600mm ,18W Single fluorescent fitting with Linear Diffuser

PROJECT NAME
08
ITEM DESCRIPTIONQTY. UNIT UNIT RATE
ITEMREF.
ELECTRICAL INSTALLATION
COLLECTION
Page No. 8/27
Page No. 8/28
Page No. 8/29
Page No. 8/30
CARRIED TO BILL NO. 8 SUMMARY
BILL OF QUANTITIES
BILL NO.
SPEC. DIV. NO.
Proposed Housing Project for relocation of Under Served Settlements, Angulana
Block- D superstructure

PAGE NO.
8/27
TOTAL PRICE RUPEES
21,000.00
21,000.00

PAGE NO.
8/28
TOTAL PRICE RUPEES
1,968,750.00
294,000.00
5,292,000.00
357,750.00
68,250.00

7,980,750.00
PAGE NO.
8/29
TOTAL PRICE RUPEES
1,181,250.00
208,080.00
1,040,400.00
150,300.00

2,580,030.00
PAGE NO.
8/30
TOTAL PRICE RUPEES
850,500.00
212,625.00
264,600.00
165,375.00
708,750.00
132,300.00
165,375.00
2,499,525.00

PAGE NO.
8/31
TOTAL PRICE RUPEES
21,000.00
7,980,750.00
2,580,030.00
2,499,525.00
13,081,305.00

PROJECT NAME
08
ITEM DESCRIPTIONQTY. UNIT UNIT RATE
ITEMREF.
8F/- ELECTRICAL INSTALLATION
Note :
General
Inspection and testing
8F/01
1 Item 21,000.00
Main Power Supply System
cables
Note :
BILL OF QUANTITIES
BILL NO.
SPEC. DIV. NO.
Proposed Housing Project for relocation of Under Served Settlements, Angulana
Block- E superstructure
All materials, equipments, wiring and workmanship shall confirm to local codes of specifications, B.S Standards, latest I.E.E regulations (17th edition) and Ceylon Electricity Board specifications. Contractor shall investigate the site conditions before submitting their quote
Contractor shall obtain sample approvals from all the items used from CEE-SEC
Contractor shall propose shop drawings/conduit layouts drawings and obtained approval from CEE-SEC before commencing installation
Testing of the complete Electrical Installation and issuing a certificate by a chartered Electrical Engineer, registered with Ceylon Electricity Board.
Rates should include for all necessary cable accessories such as cable ties, Cable Lugs, Glands, identification tags, and accessories All horizontal and vertical Cable trays should be adequately sized to provide 40% spare space.Contractor shall investigate the site conditions and include all the cost involved in point rates given below.
All the Cables quoted below shall be on measure and pay basis. Rates shall include installation of Cable taryas,Cable Ladders, PVC trunking or conduits and accessories where required .

TO COLLECTIONPROJECT NAME
08
ITEM DESCRIPTIONQTY. UNIT UNIT RATE
ITEMREF.
8F/02
150 m 13,125.00
8F/03
80 m 3,675.00
8F/04
3200 m 1,470.00
8F/05900 m 265.00
Distribution Boards.
note
note
note
note
COMMON AREA
8F/06 Lift DB 1 no 68,250.00
01 No. 4P 63A MCB 01 No. DP 32A MCB 01 No. 4P 63A,100mA RCCB01 No. DP 40A,30mA RCCB01 No. SP 20A MCB02 Nos.SP 10A MCB
BILL OF QUANTITIES
BILL NO.
SPEC. DIV. NO.
Proposed Housing Project for relocation of Under Served Settlements, Angulana
Block- E superstructure
Supply,Installation & Termination of 4 x 70mm2 XLPE/SWA/PVC/Cu Cable from MSB to Meter Room 01 (For Block C)
Supply,Installation & Termination of 4 x 16mm2 PVC/PVC/Cu + 16mm2 PVC/Cu(E) Cable from G.SDB-2 to Lift DB
Supply,Installation & Termination of 2 x 6mm2 PVC/PVC/Cu Cable from Meter Room-2 to Each House Distribution Board
Supply,Installation & Termination of 6mm2 PVC/Cu Earth Cable from DB to Cu Plate at Electrical Shaft.
All Distribution Boards shall be flush/Surface mounted type Distribution Boards complete with powder coated 1.5 mm thick sheet steel enclosure with lockable doors.
The panel board should have wire numbering and a laminated circuit diagram pasted on the inside surface of the door.
Make of MCCBs and MCBs, etc shall be Merlin Gerin / ABB / Terasaki / Hager or equivalent make approved by the Electrical Engineer.
Manufactures soft drawings should be submitted and aproved by chief electrical engineer before fabrication.

01 No. SP 16A MCB
TO COLLECTION
PROJECT NAME
08
ITEM DESCRIPTIONQTY. UNIT UNIT RATE
ITEMREF.
HOUSES
8F/07 DB.H 45 no 26,250.00
01 No. 32A DP MCB01 No. DP 40A,30mA RCCB01 No.SP 16A MCB09 Nos.SP 20A MCB
Wiring for light points, ceiling fans, socket outlets
note
note
COMMON AREA
8F/08
45 no 2,890.00
HOUSES
Flush mounted Powder Coated Steel Lockable Enclosure c/w bus bars and Accessories
BILL OF QUANTITIES
BILL NO.
SPEC. DIV. NO.
Proposed Housing Project for relocation of Under Served Settlements, Angulana
Block- E superstructure
Flush mounted Powder Coated Steel Lockable Enclosure c/w bus bars and Accessories
Rate point wiring shall include for all the conduits, conduit fittings, casings,surface cable trunks, fixing material, switches, wiring and terminations, holders for light fittings and socket outlets for power points. Contractor shall obtain approvals from the Chief Electrical Engineer for above items. Aproved samples should be displayed at the site office.
As a standard of quality for switches and socket outlets, the contractor may use 'CLIPSAL/hager /mk or approved equal'.
Supply and Installation a light point, from the respective consumer unit using 2x1mm2 PVC/PVC/CU + 1.5mm2 PVC/cu(E) cable drawn through securely fixed concealed PVC conduit controlled by a 5A flush switch as shown in the drawings.

8F/09
360 no 2,890.00
8F/10
45 no 3,340.00
TO COLLECTION
PROJECT NAME
08
ITEM DESCRIPTIONQTY. UNIT UNIT RATE
ITEMREF.
8F/11
270 no 3,150.00
8F/12
45 no 4,725.00
Light fittings
note
note
note
note
COMMON AREA
Supply and Installation a light point, from the respective consumer unit using 2x1mm2 PVC/PVC/CU cable drawn through securely fixed concealed PVC conduit controlled by a 5A flush switch as shown in the drawings.
Supply and Installation a Bell point, from the respective consumer unit using 2x1mm2 PVC/PVC/CU cable drawn through securely fixed concealed PVC conduit controlled by a Bell push as shown in the drawings.
BILL OF QUANTITIES
BILL NO.
SPEC. DIV. NO.
Proposed Housing Project for relocation of Under Served Settlements, Angulana
Block- E superstructure
Supply and Installation a 5A single switched socket outlet fixed on wall, from the respective consumer unit using 2x1.5mm2 PVC/PVC/CU + 1.5mm2PVC/cu(E) cable drawn through securely fixed concealed PVC conduit shown in the drawings.
Supply and Installation a 15A single switched socket outlet fixed on wall, from the respective consumer unit using 2x2.5mm2 PVC/PVC/CU + 2.5mm2PVC/cu(E) cable drawn through securely fixed concealed PVC conduit shown in the drawings.
The light fittings supplied and installed under this contract shall be in every respect suitable for the intended purpose.
Each fitting shall include bulbs, internal wiring, hanging and fixing material and be complete without any additional item/material being required to make it so.
All control gear of light fittings such as choke, starters, PF Correction Capacitors shall be of European make
The contractor shall obtain consultants and clients approval for the fittings before fixing the fittings in the site

8F/13 Bulk Head Lamp- Type A 45 no 3,675.00
HOUSES
8F/14 Bracket Lamp c/w 70W CFL 45 no 3,675.00
8F/15 Pendent Lamp c/w 70W CFL 270 no 2,625.00
8F/1645 no 2,940.00
8F/17 Electrical Bell With Bell Push 45 no 3,675.00
8F/18 Provisional Sum for Lightning Protection System Item
8F/19 Provisional Sum for Telephone and TV Wiring System Item
TO COLLECTION
PROJECT NAME
08
ITEM DESCRIPTIONQTY. UNIT UNIT RATE
ITEMREF.
ELECTRICAL INSTALLATION
COLLECTION
Page No. 8/27
Page No. 8/28
Page No. 8/29
Page No. 8/30
CARRIED TO BILL NO. 8 SUMMARY
600mm ,18W Single fluorescent fitting with Linear Diffuser
BILL OF QUANTITIES
BILL NO.
SPEC. DIV. NO.
Proposed Housing Project for relocation of Under Served Settlements, Angulana
Block- E superstructure


PAGE NO.
8/27
TOTAL PRICE RUPEES
21,000.00

21,000.00
PAGE NO.
8/28
TOTAL PRICE RUPEES
1,968,750.00
294,000.00
4,704,000.00
238,500.00
68,250.00

7,273,500.00
PAGE NO.
8/29
TOTAL PRICE RUPEES
1,181,250.00
130,050.00

1,040,400.00
150,300.00
2,502,000.00
PAGE NO.
8/30
TOTAL PRICE RUPEES
850,500.00
212,625.00

165,375.00
165,375.00
708,750.00
132,300.00
165,375.00
2,400,300.00
PAGE NO.
8/31
TOTAL PRICE RUPEES
21,000.00
7,273,500.00
2,502,000.00
2,400,300.00
12,196,800.00


PROJECT NAME
08
ITEM DESCRIPTIONQTY. UNIT UNIT RATE
ITEMREF.
8F/- ELECTRICAL INSTALLATION
Note :
General
Inspection and testing
8F/01
1 Item 21,000.00
Main Power Supply System
cables
Note :
BILL OF QUANTITIES
BILL NO.
SPEC. DIV. NO.
Proposed Housing Project for relocation of Under Served Settlements, Angulana
Block-F superstructure
All materials, equipments, wiring and workmanship shall confirm to local codes of specifications, B.S Standards, latest I.E.E regulations (17th edition) and Ceylon Electricity Board specifications. Contractor shall investigate the site conditions before submitting their quote
Contractor shall obtain sample approvals from all the items used from CEE-SEC
Contractor shall propose shop drawings/conduit layouts drawings and obtained approval from CEE-SEC before commencing installation
Testing of the complete Electrical Installation and issuing a certificate by a chartered Electrical Engineer, registered with Ceylon Electricity Board.
Rates should include for all necessary cable accessories such as cable ties, Cable Lugs, Glands, identification tags, and accessories All horizontal and vertical Cable trays should be adequately sized to provide 40% spare space.Contractor shall investigate the site conditions and include all the cost involved in point rates given below.
All the Cables quoted below shall be on measure and pay basis. Rates shall include installation of Cable taryas,Cable Ladders, PVC trunking or conduits and accessories where required .

TO COLLECTIONPROJECT NAME
08
ITEM DESCRIPTIONQTY. UNIT UNIT RATE
ITEMREF.
8F/02
150 m 13,125.00
8F/03
80 m 3,675.00
8F/04
2200 m 1,470.00
8F/05900 m 265.00
Distribution Boards.
note
note
note
note
COMMON AREA
8F/06 Lift DB 1 no 68,250.00
01 No. 4P 63A MCB 01 No. DP 32A MCB 01 No. 4P 63A,100mA RCCB01 No. DP 40A,30mA RCCB01 No. SP 20A MCB02 Nos.SP 10A MCB
BILL OF QUANTITIES
BILL NO.
SPEC. DIV. NO.
Proposed Housing Project for relocation of Under Served Settlements, Angulana
Block-F superstructure
Supply,Installation & Termination of 4 x 70mm2 XLPE/SWA/PVC/Cu Cable from MSB to Meter Room 01 (For Block C)
Supply,Installation & Termination of 4 x 16mm2 PVC/PVC/Cu + 16mm2 PVC/Cu(E) Cable from G.SDB-2 to Lift DB
Supply,Installation & Termination of 2 x 6mm2 PVC/PVC/Cu Cable from Meter Room-2 to Each House Distribution Board
Supply,Installation & Termination of 6mm2 PVC/Cu Earth Cable from DB to Cu Plate at Electrical Shaft.
All Distribution Boards shall be flush/Surface mounted type Distribution Boards complete with powder coated 1.5 mm thick sheet steel enclosure with lockable doors.
The panel board should have wire numbering and a laminated circuit diagram pasted on the inside surface of the door.
Make of MCCBs and MCBs, etc shall be Merlin Gerin / ABB / Terasaki / Hager or equivalent make approved by the Electrical Engineer.
Manufactures soft drawings should be submitted and aproved by chief electrical engineer before fabrication.

01 No. SP 16A MCB
TO COLLECTION
PROJECT NAME
08
ITEM DESCRIPTIONQTY. UNIT UNIT RATE
ITEMREF.
HOUSES
8F/07 DB.H 36 no 26,250.00
01 No. 32A DP MCB01 No. DP 40A,30mA RCCB01 No.SP 16A MCB09 Nos.SP 20A MCB
Wiring for light points, ceiling fans, socket outlets
note
note
COMMON AREA
8F/08
72 no 2,890.00
HOUSES
Flush mounted Powder Coated Steel Lockable Enclosure c/w bus bars and Accessories
BILL OF QUANTITIES
BILL NO.
SPEC. DIV. NO.
Proposed Housing Project for relocation of Under Served Settlements, Angulana
Block-F superstructure
Flush mounted Powder Coated Steel Lockable Enclosure c/w bus bars and Accessories
Rate point wiring shall include for all the conduits, conduit fittings, casings,surface cable trunks, fixing material, switches, wiring and terminations, holders for light fittings and socket outlets for power points. Contractor shall obtain approvals from the Chief Electrical Engineer for above items. Aproved samples should be displayed at the site office.
As a standard of quality for switches and socket outlets, the contractor may use 'CLIPSAL/hager /mk or approved equal'.
Supply and Installation a light point, from the respective consumer unit using 2x1mm2 PVC/PVC/CU + 1.5mm2 PVC/cu(E) cable drawn through securely fixed concealed PVC conduit controlled by a 5A flush switch as shown in the drawings.

8F/09
288 no 2,890.00
8F/10
36 no 3,340.00
TO COLLECTION
PROJECT NAME
08
ITEM DESCRIPTIONQTY. UNIT UNIT RATE
ITEMREF.
8F/11
216 no 3,150.00
8F/12
36 no 4,725.00
Light fittings
note
note
note
note
COMMON AREA
Supply and Installation a light point, from the respective consumer unit using 2x1mm2 PVC/PVC/CU cable drawn through securely fixed concealed PVC conduit controlled by a 5A flush switch as shown in the drawings.
Supply and Installation a Bell point, from the respective consumer unit using 2x1mm2 PVC/PVC/CU cable drawn through securely fixed concealed PVC conduit controlled by a Bell push as shown in the drawings.
BILL OF QUANTITIES
BILL NO.
SPEC. DIV. NO.
Proposed Housing Project for relocation of Under Served Settlements, Angulana
Block-F superstructure
Supply and Installation a 5A single switched socket outlet fixed on wall, from the respective consumer unit using 2x1.5mm2 PVC/PVC/CU + 1.5mm2PVC/cu(E) cable drawn through securely fixed concealed PVC conduit shown in the drawings.
Supply and Installation a 15A single switched socket outlet fixed on wall, from the respective consumer unit using 2x2.5mm2 PVC/PVC/CU + 2.5mm2PVC/cu(E) cable drawn through securely fixed concealed PVC conduit shown in the drawings.
The light fittings supplied and installed under this contract shall be in every respect suitable for the intended purpose.
Each fitting shall include bulbs, internal wiring, hanging and fixing material and be complete without any additional item/material being required to make it so.
All control gear of light fittings such as choke, starters, PF Correction Capacitors shall be of European make
The contractor shall obtain consultants and clients approval for the fittings before fixing the fittings in the site

8F/13 Bulk Head Lamp- Type A 72 no 3,675.00
HOUSES
8F/14 Bracket Lamp c/w 70W CFL 36 no 3,675.00
8F/15 Pendent Lamp c/w 70W CFL 216 no 2,625.00
8F/1636 no 2,940.00
8F/17 Electrical Bell With Bell Push 36 no 3,675.00
8F/18 Provisional Sum for Lightning Protection System Item
8F/19 Provisional Sum for Telephone and TV Wiring System Item
TO COLLECTION
PROJECT NAME
08
ITEM DESCRIPTIONQTY. UNIT UNIT RATE
ITEMREF.
ELECTRICAL INSTALLATION
COLLECTION
Page No. 8/27
Page No. 8/28
Page No. 8/29
Page No. 8/30
CARRIED TO BILL NO. 8 SUMMARY
600mm ,18W Single fluorescent fitting with Linear Diffuser
BILL OF QUANTITIES
BILL NO.
SPEC. DIV. NO.
Proposed Housing Project for relocation of Under Served Settlements, Angulana
Block-F superstructure


PAGE NO.
8/27
TOTAL PRICE RUPEES
21,000.00

21,000.00
PAGE NO.
8/28
TOTAL PRICE RUPEES
1,968,750.00
294,000.00
3,234,000.00
238,500.00
68,250.00

5,803,500.00
PAGE NO.
8/29
TOTAL PRICE RUPEES
945,000.00
208,080.00

832,320.00
120,240.00
2,105,640.00
PAGE NO.
8/30
TOTAL PRICE RUPEES
680,400.00
170,100.00

264,600.00
132,300.00
567,000.00
105,840.00
132,300.00
2,052,540.00
PAGE NO.
8/31
TOTAL PRICE RUPEES
21,000.00
5,803,500.00
2,105,640.00
2,052,540.00
9,982,680.00


PROJECT NAME
08
ITEM DESCRIPTIONQTY. UNIT UNIT RATE
ITEMREF.
8F/- ELECTRICAL INSTALLATION
Note :
General
Inspection and testing
8F/01
1 Item 21,000.00
Main Power Supply System
cables
Note :
BILL OF QUANTITIES
BILL NO.
SPEC. DIV. NO.
Proposed Housing Project for relocation of Under Served Settlements, Angulana
Block-G superstructure
All materials, equipments, wiring and workmanship shall confirm to local codes of specifications, B.S Standards, latest I.E.E regulations (17th edition) and Ceylon Electricity Board specifications. Contractor shall investigate the site conditions before submitting their quote
Contractor shall obtain sample approvals from all the items used from CEE-SEC
Contractor shall propose shop drawings/conduit layouts drawings and obtained approval from CEE-SEC before commencing installation
Testing of the complete Electrical Installation and issuing a certificate by a chartered Electrical Engineer, registered with Ceylon Electricity Board.
Rates should include for all necessary cable accessories such as cable ties, Cable Lugs, Glands, identification tags, and accessories All horizontal and vertical Cable trays should be adequately sized to provide 40% spare space.Contractor shall investigate the site conditions and include all the cost involved in point rates given below.
All the Cables quoted below shall be on measure and pay basis. Rates shall include installation of Cable taryas,Cable Ladders, PVC trunking or conduits and accessories where required .

TO COLLECTIONPROJECT NAME
08
ITEM DESCRIPTIONQTY. UNIT UNIT RATE
ITEMREF.
8F/02
150 m 13,125.00
8F/03
80 m 3,675.00
8F/04
2000 m 1,470.00
8F/05900 m 265.00
Distribution Boards.
note
note
note
note
COMMON AREA
8F/06 Lift DB 1 no 68,250.00
01 No. 4P 63A MCB 01 No. DP 32A MCB 01 No. 4P 63A,100mA RCCB01 No. DP 40A,30mA RCCB01 No. SP 20A MCB02 Nos.SP 10A MCB
BILL OF QUANTITIES
BILL NO.
SPEC. DIV. NO.
Proposed Housing Project for relocation of Under Served Settlements, Angulana
Block-G superstructure
Supply,Installation & Termination of 4 x 70mm2 XLPE/SWA/PVC/Cu Cable from MSB to Meter Room 01 (For Block C)
Supply,Installation & Termination of 4 x 16mm2 PVC/PVC/Cu + 16mm2 PVC/Cu(E) Cable from G.SDB-2 to Lift DB
Supply,Installation & Termination of 2 x 6mm2 PVC/PVC/Cu Cable from Meter Room-2 to Each House Distribution Board
Supply,Installation & Termination of 6mm2 PVC/Cu Earth Cable from DB to Cu Plate at Electrical Shaft.
All Distribution Boards shall be flush/Surface mounted type Distribution Boards complete with powder coated 1.5 mm thick sheet steel enclosure with lockable doors.
The panel board should have wire numbering and a laminated circuit diagram pasted on the inside surface of the door.
Make of MCCBs and MCBs, etc shall be Merlin Gerin / ABB / Terasaki / Hager or equivalent make approved by the Electrical Engineer.
Manufactures soft drawings should be submitted and aproved by chief electrical engineer before fabrication.

01 No. SP 16A MCB
TO COLLECTION
PROJECT NAME
08
ITEM DESCRIPTIONQTY. UNIT UNIT RATE
ITEMREF.
HOUSES
8F/07 DB.H 27 no 26,250.00
01 No. 32A DP MCB01 No. DP 40A,30mA RCCB01 No.SP 16A MCB09 Nos.SP 20A MCB
Wiring for light points, ceiling fans, socket outlets
note
note
COMMON AREA
8F/08
19 no 2,890.00
HOUSES
Flush mounted Powder Coated Steel Lockable Enclosure c/w bus bars and Accessories
BILL OF QUANTITIES
BILL NO.
SPEC. DIV. NO.
Proposed Housing Project for relocation of Under Served Settlements, Angulana
Block-G superstructure
Flush mounted Powder Coated Steel Lockable Enclosure c/w bus bars and Accessories
Rate point wiring shall include for all the conduits, conduit fittings, casings,surface cable trunks, fixing material, switches, wiring and terminations, holders for light fittings and socket outlets for power points. Contractor shall obtain approvals from the Chief Electrical Engineer for above items. Aproved samples should be displayed at the site office.
As a standard of quality for switches and socket outlets, the contractor may use 'CLIPSAL/hager /mk or approved equal'.
Supply and Installation a light point, from the respective consumer unit using 2x1mm2 PVC/PVC/CU + 1.5mm2 PVC/cu(E) cable drawn through securely fixed concealed PVC conduit controlled by a 5A flush switch as shown in the drawings.

8F/09
216 no 2,890.00
8F/10
27 no 3,340.00
TO COLLECTION
PROJECT NAME
08
ITEM DESCRIPTIONQTY. UNIT UNIT RATE
ITEMREF.
8F/11
162 no 3,150.00
8F/12
27 no 4,725.00
Light fittings
note
note
note
note
COMMON AREA
Supply and Installation a light point, from the respective consumer unit using 2x1mm2 PVC/PVC/CU cable drawn through securely fixed concealed PVC conduit controlled by a 5A flush switch as shown in the drawings.
Supply and Installation a Bell point, from the respective consumer unit using 2x1mm2 PVC/PVC/CU cable drawn through securely fixed concealed PVC conduit controlled by a Bell push as shown in the drawings.
BILL OF QUANTITIES
BILL NO.
SPEC. DIV. NO.
Proposed Housing Project for relocation of Under Served Settlements, Angulana
Block-G superstructure
Supply and Installation a 5A single switched socket outlet fixed on wall, from the respective consumer unit using 2x1.5mm2 PVC/PVC/CU + 1.5mm2PVC/cu(E) cable drawn through securely fixed concealed PVC conduit shown in the drawings.
Supply and Installation a 15A single switched socket outlet fixed on wall, from the respective consumer unit using 2x2.5mm2 PVC/PVC/CU + 2.5mm2PVC/cu(E) cable drawn through securely fixed concealed PVC conduit shown in the drawings.
The light fittings supplied and installed under this contract shall be in every respect suitable for the intended purpose.
Each fitting shall include bulbs, internal wiring, hanging and fixing material and be complete without any additional item/material being required to make it so.
All control gear of light fittings such as choke, starters, PF Correction Capacitors shall be of European make
The contractor shall obtain consultants and clients approval for the fittings before fixing the fittings in the site

8F/13 Bulk Head Lamp- Type A 19 no 3,675.00
HOUSES
8F/14 Bracket Lamp c/w 70W CFL 27 no 3,675.00 .
8F/15 Pendent Lamp c/w 70W CFL 162 no 2,625.00
8F/1627 no 2,940.00
8F/17 Electrical Bell With Bell Push 27 no 3,675.00
8F/18 Provisional Sum for Lightning Protection System Item
8F/19 Provisional Sum for Telephone and TV Wiring System Item
TO COLLECTION
PROJECT NAME
08
ITEM DESCRIPTIONQTY. UNIT UNIT RATE
ITEMREF.
ELECTRICAL INSTALLATION
COLLECTION
Page No. 8/27
Page No. 8/28
Page No. 8/29
Page No. 8/30
CARRIED TO BILL NO. 8 SUMMARY
600mm ,18W Single fluorescent fitting with Linear Diffuser
BILL OF QUANTITIES
BILL NO.
SPEC. DIV. NO.
Proposed Housing Project for relocation of Under Served Settlements, Angulana
Block-G superstructure


PAGE NO.
8/27
TOTAL PRICE RUPEES
21,000.00

21,000.00
PAGE NO.
8/28
TOTAL PRICE RUPEES
1,968,750.00
294,000.00
2,940,000.00
238,500.00
68,250.00

5,509,500.00
PAGE NO.
8/29
TOTAL PRICE RUPEES
708,750.00
54,910.00

624,240.00
90,180.00
1,478,080.00
PAGE NO.
8/30
TOTAL PRICE RUPEES
510,300.00
127,575.00

69,825.00
99,225.00
425,250.00
79,380.00
99,225.00
1,410,780.00
PAGE NO.
8/31
TOTAL PRICE RUPEES
21,000.00
5,509,500.00
1,478,080.00
1,410,780.00
8,419,360.00