Electrical BOQ

46
PROJECT NAME 08 ITEM DESCRIPTION QTY. UNIT UNIT RATE ITEM REF. 8F/- ELECTRICAL INSTALLATION Note : General Inspection and testing 8F/01 1 Item 21,000.00 Main Power Supply System cables Note : TO COLLECTION BILL OF QUANTITIES BILL NO. SPEC. DIV. NO. Proposed Housing Project for relocation of Under Served Settlements, Angulana superstructur e All materials, equipments, wiring and workmanship shall confirm to local codes of specifications, B.S Standards, latest I.E.E regulations (17th edition) and Ceylon Electricity Board specifications. Contractor shall investigate the site conditions before submitting their quote Contractor shall obtain sample approvals from all the items used from CEE-SEC Contractor shall propose shop drawings/conduit layouts drawings and obtained approval from CEE-SEC before Testing of the complete Electrical Installation and issuing a certificate by a chartered Electrical Engineer, registered Rates should include for all necessary cable accessories such as cable ties, Cable Lugs, Glands, identification tags, and accessories All horizontal and vertical Cable trays should be adequately sized to provide 40% spare space.Contractor shall investigate the site conditions and include all the cost involved in point rates given below. All the Cables quoted below shall be on measure and pay basis. Rates shall include installation of Cable taryas,Cable Ladders, PVC trunking or conduits and accessories where required .

description

Electrical BOQ

Transcript of Electrical BOQ

Page 1: Electrical BOQ

PROJECT NAME

08

ITEM DESCRIPTIONQTY. UNIT UNIT RATE

ITEMREF.

8F/- ELECTRICAL INSTALLATION

Note :

General

Inspection and testing

8F/01

1 Item 21,000.00

Main Power Supply System

cables

Note :

TO COLLECTION

BILL OF QUANTITIES

BILL NO.

SPEC. DIV. NO.

Proposed Housing Project for relocation of Under Served Settlements, Angulana

Block- D superstructure

All materials, equipments, wiring and workmanship shall confirm to local codes of specifications, B.S Standards, latest I.E.E regulations (17th edition) and Ceylon Electricity Board specifications. Contractor shall investigate the site conditions before submitting their quote

Contractor shall obtain sample approvals from all the items used from CEE-SEC

Contractor shall propose shop drawings/conduit layouts drawings and obtained approval from CEE-SEC before commencing installation

Testing of the complete Electrical Installation and issuing a certificate by a chartered Electrical Engineer, registered with Ceylon Electricity Board.

Rates should include for all necessary cable accessories such as cable ties, Cable Lugs, Glands, identification tags, and accessories All horizontal and vertical Cable trays should be adequately sized to provide 40% spare space.Contractor shall investigate the site conditions and include all the cost involved in point rates given below.

All the Cables quoted below shall be on measure and pay basis. Rates shall include installation of Cable taryas,Cable Ladders, PVC trunking or conduits and accessories where required .

Page 2: Electrical BOQ

PROJECT NAME

08

ITEM DESCRIPTIONQTY. UNIT UNIT RATE

ITEMREF.

8F/02

150 m 13,125.00

8F/03

80 m 3,675.00

8F/04

3600 m 1,470.00

8F/051350 m 265.00

Distribution Boards.

note

note

note

note

COMMON AREA

8F/06 Lift DB 1 no 68,250.00

01 No. 4P 63A MCB 01 No. DP 32A MCB 01 No. 4P 63A,100mA RCCB01 No. DP 40A,30mA RCCB01 No. SP 20A MCB02 Nos.SP 10A MCB01 No. SP 16A MCB

BILL OF QUANTITIES

BILL NO.

SPEC. DIV. NO.

Proposed Housing Project for relocation of Under Served Settlements, Angulana

Block- D superstructure

Supply,Installation & Termination of 4 x 70mm2 XLPE/SWA/PVC/Cu Cable from MSB to Meter Room 01 (For Block C)

Supply,Installation & Termination of 4 x 16mm2 PVC/PVC/Cu + 16mm2 PVC/Cu(E) Cable from G.SDB-2 to Lift DB

Supply,Installation & Termination of 2 x 6mm2 PVC/PVC/Cu Cable from Meter Room-2 to Each House Distribution Board

Supply,Installation & Termination of 6mm2 PVC/Cu Earth Cable from DB to Cu Plate at Electrical Shaft.

All Distribution Boards shall be flush/Surface mounted type Distribution Boards complete with powder coated 1.5 mm thick sheet steel enclosure with lockable doors.

The panel board should have wire numbering and a laminated circuit diagram pasted on the inside surface of the door.

Make of MCCBs and MCBs, etc shall be Merlin Gerin / ABB / Terasaki / Hager or equivalent make approved by the Electrical Engineer.

Manufactures soft drawings should be submitted and aproved by chief electrical engineer before fabrication.

Flush mounted Powder Coated Steel Lockable Enclosure c/w bus bars and Accessories

Page 3: Electrical BOQ

TO COLLECTION

PROJECT NAME

08

ITEM DESCRIPTIONQTY. UNIT UNIT RATE

ITEMREF.

HOUSES

8F/07 DB.H 45 no 26,250.00

01 No. 32A DP MCB01 No. DP 40A,30mA RCCB01 No.SP 16A MCB09 Nos.SP 20A MCB

Wiring for light points, ceiling fans, socket outlets

note

note

COMMON AREA

8F/08

72 no 2,890.00

HOUSES

8F/09

360 no 2,890.00

8F/10

45 no 3,340.00

BILL OF QUANTITIES

BILL NO.

SPEC. DIV. NO.

Proposed Housing Project for relocation of Under Served Settlements, Angulana

Block- D superstructure

Flush mounted Powder Coated Steel Lockable Enclosure c/w bus bars and Accessories

Rate point wiring shall include for all the conduits, conduit fittings, casings,surface cable trunks, fixing material, switches, wiring and terminations, holders for light fittings and socket outlets for power points. Contractor shall obtain approvals from the Chief Electrical Engineer for above items. Aproved samples should be displayed at the site office.

As a standard of quality for switches and socket outlets, the contractor may use 'CLIPSAL/hager /mk or approved equal'.

Supply and Installation a light point, from the respective consumer unit using 2x1mm2 PVC/PVC/CU + 1.5mm2 PVC/cu(E) cable drawn through securely fixed concealed PVC conduit controlled by a 5A flush switch as shown in the drawings.

Supply and Installation a light point, from the respective consumer unit using 2x1mm2 PVC/PVC/CU cable drawn through securely fixed concealed PVC conduit controlled by a 5A flush switch as shown in the drawings.

Supply and Installation a Bell point, from the respective consumer unit using 2x1mm2 PVC/PVC/CU cable drawn through securely fixed concealed PVC conduit controlled by a Bell push as shown in the drawings.

Page 4: Electrical BOQ

TO COLLECTION

PROJECT NAME

08

ITEM DESCRIPTIONQTY. UNIT UNIT RATE

ITEMREF.

8F/11

270 no 3,150.00

8F/12

45 no 4,725.00

Light fittings

note

note

note

note

COMMON AREA

8F/13 Bulk Head Lamp- Type A 72 no 3,675.00

HOUSES

8F/14 Bracket Lamp c/w 70W CFL 45 no 3,675.00

8F/15 Pendent Lamp c/w 70W CFL 270 no 2,625.00

8F/1645 no 2,940.00

8F/17 Electrical Bell With Bell Push 45 no 3,675.00

8F/18 Provisional Sum for Lightning Protection System Item

8F/19 Provisional Sum for Telephone and TV Wiring System Item

TO COLLECTION

BILL OF QUANTITIES

BILL NO.

SPEC. DIV. NO.

Proposed Housing Project for relocation of Under Served Settlements, Angulana

Block- D superstructure

Supply and Installation a 5A single switched socket outlet fixed on wall, from the respective consumer unit using 2x1.5mm2 PVC/PVC/CU + 1.5mm2PVC/cu(E) cable drawn through securely fixed concealed PVC conduit shown in the drawings.

Supply and Installation a 15A single switched socket outlet fixed on wall, from the respective consumer unit using 2x2.5mm2 PVC/PVC/CU + 2.5mm2PVC/cu(E) cable drawn through securely fixed concealed PVC conduit shown in the drawings.

The light fittings supplied and installed under this contract shall be in every respect suitable for the intended purpose.

Each fitting shall include bulbs, internal wiring, hanging and fixing material and be complete without any additional item/material being required to make it so.

All control gear of light fittings such as choke, starters, PF Correction Capacitors shall be of European make

The contractor shall obtain consultants and clients approval for the fittings before fixing the fittings in the site

600mm ,18W Single fluorescent fitting with Linear Diffuser

Page 5: Electrical BOQ

PROJECT NAME

08

ITEM DESCRIPTIONQTY. UNIT UNIT RATE

ITEMREF.

ELECTRICAL INSTALLATION

COLLECTION

Page No. 8/27

Page No. 8/28

Page No. 8/29

Page No. 8/30

CARRIED TO BILL NO. 8 SUMMARY

BILL OF QUANTITIES

BILL NO.

SPEC. DIV. NO.

Proposed Housing Project for relocation of Under Served Settlements, Angulana

Block- D superstructure

Page 6: Electrical BOQ

PAGE NO.

8/27

TOTAL PRICE RUPEES

21,000.00

21,000.00

Page 7: Electrical BOQ

PAGE NO.

8/28

TOTAL PRICE RUPEES

1,968,750.00

294,000.00

5,292,000.00

357,750.00

68,250.00

Page 8: Electrical BOQ

7,980,750.00

PAGE NO.

8/29

TOTAL PRICE RUPEES

1,181,250.00

208,080.00

1,040,400.00

150,300.00

Page 9: Electrical BOQ

2,580,030.00

PAGE NO.

8/30

TOTAL PRICE RUPEES

850,500.00

212,625.00

264,600.00

165,375.00

708,750.00

132,300.00

165,375.00

2,499,525.00

Page 10: Electrical BOQ

PAGE NO.

8/31

TOTAL PRICE RUPEES

21,000.00

7,980,750.00

2,580,030.00

2,499,525.00

13,081,305.00

Page 11: Electrical BOQ

PROJECT NAME

08

ITEM DESCRIPTIONQTY. UNIT UNIT RATE

ITEMREF.

8F/- ELECTRICAL INSTALLATION

Note :

General

Inspection and testing

8F/01

1 Item 21,000.00

Main Power Supply System

cables

Note :

BILL OF QUANTITIES

BILL NO.

SPEC. DIV. NO.

Proposed Housing Project for relocation of Under Served Settlements, Angulana

Block- E superstructure

All materials, equipments, wiring and workmanship shall confirm to local codes of specifications, B.S Standards, latest I.E.E regulations (17th edition) and Ceylon Electricity Board specifications. Contractor shall investigate the site conditions before submitting their quote

Contractor shall obtain sample approvals from all the items used from CEE-SEC

Contractor shall propose shop drawings/conduit layouts drawings and obtained approval from CEE-SEC before commencing installation

Testing of the complete Electrical Installation and issuing a certificate by a chartered Electrical Engineer, registered with Ceylon Electricity Board.

Rates should include for all necessary cable accessories such as cable ties, Cable Lugs, Glands, identification tags, and accessories All horizontal and vertical Cable trays should be adequately sized to provide 40% spare space.Contractor shall investigate the site conditions and include all the cost involved in point rates given below.

All the Cables quoted below shall be on measure and pay basis. Rates shall include installation of Cable taryas,Cable Ladders, PVC trunking or conduits and accessories where required .

Page 12: Electrical BOQ

TO COLLECTIONPROJECT NAME

08

ITEM DESCRIPTIONQTY. UNIT UNIT RATE

ITEMREF.

8F/02

150 m 13,125.00

8F/03

80 m 3,675.00

8F/04

3200 m 1,470.00

8F/05900 m 265.00

Distribution Boards.

note

note

note

note

COMMON AREA

8F/06 Lift DB 1 no 68,250.00

01 No. 4P 63A MCB 01 No. DP 32A MCB 01 No. 4P 63A,100mA RCCB01 No. DP 40A,30mA RCCB01 No. SP 20A MCB02 Nos.SP 10A MCB

BILL OF QUANTITIES

BILL NO.

SPEC. DIV. NO.

Proposed Housing Project for relocation of Under Served Settlements, Angulana

Block- E superstructure

Supply,Installation & Termination of 4 x 70mm2 XLPE/SWA/PVC/Cu Cable from MSB to Meter Room 01 (For Block C)

Supply,Installation & Termination of 4 x 16mm2 PVC/PVC/Cu + 16mm2 PVC/Cu(E) Cable from G.SDB-2 to Lift DB

Supply,Installation & Termination of 2 x 6mm2 PVC/PVC/Cu Cable from Meter Room-2 to Each House Distribution Board

Supply,Installation & Termination of 6mm2 PVC/Cu Earth Cable from DB to Cu Plate at Electrical Shaft.

All Distribution Boards shall be flush/Surface mounted type Distribution Boards complete with powder coated 1.5 mm thick sheet steel enclosure with lockable doors.

The panel board should have wire numbering and a laminated circuit diagram pasted on the inside surface of the door.

Make of MCCBs and MCBs, etc shall be Merlin Gerin / ABB / Terasaki / Hager or equivalent make approved by the Electrical Engineer.

Manufactures soft drawings should be submitted and aproved by chief electrical engineer before fabrication.

Page 13: Electrical BOQ

01 No. SP 16A MCB

TO COLLECTION

PROJECT NAME

08

ITEM DESCRIPTIONQTY. UNIT UNIT RATE

ITEMREF.

HOUSES

8F/07 DB.H 45 no 26,250.00

01 No. 32A DP MCB01 No. DP 40A,30mA RCCB01 No.SP 16A MCB09 Nos.SP 20A MCB

Wiring for light points, ceiling fans, socket outlets

note

note

COMMON AREA

8F/08

45 no 2,890.00

HOUSES

Flush mounted Powder Coated Steel Lockable Enclosure c/w bus bars and Accessories

BILL OF QUANTITIES

BILL NO.

SPEC. DIV. NO.

Proposed Housing Project for relocation of Under Served Settlements, Angulana

Block- E superstructure

Flush mounted Powder Coated Steel Lockable Enclosure c/w bus bars and Accessories

Rate point wiring shall include for all the conduits, conduit fittings, casings,surface cable trunks, fixing material, switches, wiring and terminations, holders for light fittings and socket outlets for power points. Contractor shall obtain approvals from the Chief Electrical Engineer for above items. Aproved samples should be displayed at the site office.

As a standard of quality for switches and socket outlets, the contractor may use 'CLIPSAL/hager /mk or approved equal'.

Supply and Installation a light point, from the respective consumer unit using 2x1mm2 PVC/PVC/CU + 1.5mm2 PVC/cu(E) cable drawn through securely fixed concealed PVC conduit controlled by a 5A flush switch as shown in the drawings.

Page 14: Electrical BOQ

8F/09

360 no 2,890.00

8F/10

45 no 3,340.00

TO COLLECTION

PROJECT NAME

08

ITEM DESCRIPTIONQTY. UNIT UNIT RATE

ITEMREF.

8F/11

270 no 3,150.00

8F/12

45 no 4,725.00

Light fittings

note

note

note

note

COMMON AREA

Supply and Installation a light point, from the respective consumer unit using 2x1mm2 PVC/PVC/CU cable drawn through securely fixed concealed PVC conduit controlled by a 5A flush switch as shown in the drawings.

Supply and Installation a Bell point, from the respective consumer unit using 2x1mm2 PVC/PVC/CU cable drawn through securely fixed concealed PVC conduit controlled by a Bell push as shown in the drawings.

BILL OF QUANTITIES

BILL NO.

SPEC. DIV. NO.

Proposed Housing Project for relocation of Under Served Settlements, Angulana

Block- E superstructure

Supply and Installation a 5A single switched socket outlet fixed on wall, from the respective consumer unit using 2x1.5mm2 PVC/PVC/CU + 1.5mm2PVC/cu(E) cable drawn through securely fixed concealed PVC conduit shown in the drawings.

Supply and Installation a 15A single switched socket outlet fixed on wall, from the respective consumer unit using 2x2.5mm2 PVC/PVC/CU + 2.5mm2PVC/cu(E) cable drawn through securely fixed concealed PVC conduit shown in the drawings.

The light fittings supplied and installed under this contract shall be in every respect suitable for the intended purpose.

Each fitting shall include bulbs, internal wiring, hanging and fixing material and be complete without any additional item/material being required to make it so.

All control gear of light fittings such as choke, starters, PF Correction Capacitors shall be of European make

The contractor shall obtain consultants and clients approval for the fittings before fixing the fittings in the site

Page 15: Electrical BOQ

8F/13 Bulk Head Lamp- Type A 45 no 3,675.00

HOUSES

8F/14 Bracket Lamp c/w 70W CFL 45 no 3,675.00

8F/15 Pendent Lamp c/w 70W CFL 270 no 2,625.00

8F/1645 no 2,940.00

8F/17 Electrical Bell With Bell Push 45 no 3,675.00

8F/18 Provisional Sum for Lightning Protection System Item

8F/19 Provisional Sum for Telephone and TV Wiring System Item

TO COLLECTION

PROJECT NAME

08

ITEM DESCRIPTIONQTY. UNIT UNIT RATE

ITEMREF.

ELECTRICAL INSTALLATION

COLLECTION

Page No. 8/27

Page No. 8/28

Page No. 8/29

Page No. 8/30

CARRIED TO BILL NO. 8 SUMMARY

600mm ,18W Single fluorescent fitting with Linear Diffuser

BILL OF QUANTITIES

BILL NO.

SPEC. DIV. NO.

Proposed Housing Project for relocation of Under Served Settlements, Angulana

Block- E superstructure

Page 16: Electrical BOQ
Page 17: Electrical BOQ

PAGE NO.

8/27

TOTAL PRICE RUPEES

21,000.00

Page 18: Electrical BOQ

21,000.00

PAGE NO.

8/28

TOTAL PRICE RUPEES

1,968,750.00

294,000.00

4,704,000.00

238,500.00

68,250.00

Page 19: Electrical BOQ

7,273,500.00

PAGE NO.

8/29

TOTAL PRICE RUPEES

1,181,250.00

130,050.00

Page 20: Electrical BOQ

1,040,400.00

150,300.00

2,502,000.00

PAGE NO.

8/30

TOTAL PRICE RUPEES

850,500.00

212,625.00

Page 21: Electrical BOQ

165,375.00

165,375.00

708,750.00

132,300.00

165,375.00

2,400,300.00

PAGE NO.

8/31

TOTAL PRICE RUPEES

21,000.00

7,273,500.00

2,502,000.00

2,400,300.00

12,196,800.00

Page 22: Electrical BOQ
Page 23: Electrical BOQ

PROJECT NAME

08

ITEM DESCRIPTIONQTY. UNIT UNIT RATE

ITEMREF.

8F/- ELECTRICAL INSTALLATION

Note :

General

Inspection and testing

8F/01

1 Item 21,000.00

Main Power Supply System

cables

Note :

BILL OF QUANTITIES

BILL NO.

SPEC. DIV. NO.

Proposed Housing Project for relocation of Under Served Settlements, Angulana

Block-F superstructure

All materials, equipments, wiring and workmanship shall confirm to local codes of specifications, B.S Standards, latest I.E.E regulations (17th edition) and Ceylon Electricity Board specifications. Contractor shall investigate the site conditions before submitting their quote

Contractor shall obtain sample approvals from all the items used from CEE-SEC

Contractor shall propose shop drawings/conduit layouts drawings and obtained approval from CEE-SEC before commencing installation

Testing of the complete Electrical Installation and issuing a certificate by a chartered Electrical Engineer, registered with Ceylon Electricity Board.

Rates should include for all necessary cable accessories such as cable ties, Cable Lugs, Glands, identification tags, and accessories All horizontal and vertical Cable trays should be adequately sized to provide 40% spare space.Contractor shall investigate the site conditions and include all the cost involved in point rates given below.

All the Cables quoted below shall be on measure and pay basis. Rates shall include installation of Cable taryas,Cable Ladders, PVC trunking or conduits and accessories where required .

Page 24: Electrical BOQ

TO COLLECTIONPROJECT NAME

08

ITEM DESCRIPTIONQTY. UNIT UNIT RATE

ITEMREF.

8F/02

150 m 13,125.00

8F/03

80 m 3,675.00

8F/04

2200 m 1,470.00

8F/05900 m 265.00

Distribution Boards.

note

note

note

note

COMMON AREA

8F/06 Lift DB 1 no 68,250.00

01 No. 4P 63A MCB 01 No. DP 32A MCB 01 No. 4P 63A,100mA RCCB01 No. DP 40A,30mA RCCB01 No. SP 20A MCB02 Nos.SP 10A MCB

BILL OF QUANTITIES

BILL NO.

SPEC. DIV. NO.

Proposed Housing Project for relocation of Under Served Settlements, Angulana

Block-F superstructure

Supply,Installation & Termination of 4 x 70mm2 XLPE/SWA/PVC/Cu Cable from MSB to Meter Room 01 (For Block C)

Supply,Installation & Termination of 4 x 16mm2 PVC/PVC/Cu + 16mm2 PVC/Cu(E) Cable from G.SDB-2 to Lift DB

Supply,Installation & Termination of 2 x 6mm2 PVC/PVC/Cu Cable from Meter Room-2 to Each House Distribution Board

Supply,Installation & Termination of 6mm2 PVC/Cu Earth Cable from DB to Cu Plate at Electrical Shaft.

All Distribution Boards shall be flush/Surface mounted type Distribution Boards complete with powder coated 1.5 mm thick sheet steel enclosure with lockable doors.

The panel board should have wire numbering and a laminated circuit diagram pasted on the inside surface of the door.

Make of MCCBs and MCBs, etc shall be Merlin Gerin / ABB / Terasaki / Hager or equivalent make approved by the Electrical Engineer.

Manufactures soft drawings should be submitted and aproved by chief electrical engineer before fabrication.

Page 25: Electrical BOQ

01 No. SP 16A MCB

TO COLLECTION

PROJECT NAME

08

ITEM DESCRIPTIONQTY. UNIT UNIT RATE

ITEMREF.

HOUSES

8F/07 DB.H 36 no 26,250.00

01 No. 32A DP MCB01 No. DP 40A,30mA RCCB01 No.SP 16A MCB09 Nos.SP 20A MCB

Wiring for light points, ceiling fans, socket outlets

note

note

COMMON AREA

8F/08

72 no 2,890.00

HOUSES

Flush mounted Powder Coated Steel Lockable Enclosure c/w bus bars and Accessories

BILL OF QUANTITIES

BILL NO.

SPEC. DIV. NO.

Proposed Housing Project for relocation of Under Served Settlements, Angulana

Block-F superstructure

Flush mounted Powder Coated Steel Lockable Enclosure c/w bus bars and Accessories

Rate point wiring shall include for all the conduits, conduit fittings, casings,surface cable trunks, fixing material, switches, wiring and terminations, holders for light fittings and socket outlets for power points. Contractor shall obtain approvals from the Chief Electrical Engineer for above items. Aproved samples should be displayed at the site office.

As a standard of quality for switches and socket outlets, the contractor may use 'CLIPSAL/hager /mk or approved equal'.

Supply and Installation a light point, from the respective consumer unit using 2x1mm2 PVC/PVC/CU + 1.5mm2 PVC/cu(E) cable drawn through securely fixed concealed PVC conduit controlled by a 5A flush switch as shown in the drawings.

Page 26: Electrical BOQ

8F/09

288 no 2,890.00

8F/10

36 no 3,340.00

TO COLLECTION

PROJECT NAME

08

ITEM DESCRIPTIONQTY. UNIT UNIT RATE

ITEMREF.

8F/11

216 no 3,150.00

8F/12

36 no 4,725.00

Light fittings

note

note

note

note

COMMON AREA

Supply and Installation a light point, from the respective consumer unit using 2x1mm2 PVC/PVC/CU cable drawn through securely fixed concealed PVC conduit controlled by a 5A flush switch as shown in the drawings.

Supply and Installation a Bell point, from the respective consumer unit using 2x1mm2 PVC/PVC/CU cable drawn through securely fixed concealed PVC conduit controlled by a Bell push as shown in the drawings.

BILL OF QUANTITIES

BILL NO.

SPEC. DIV. NO.

Proposed Housing Project for relocation of Under Served Settlements, Angulana

Block-F superstructure

Supply and Installation a 5A single switched socket outlet fixed on wall, from the respective consumer unit using 2x1.5mm2 PVC/PVC/CU + 1.5mm2PVC/cu(E) cable drawn through securely fixed concealed PVC conduit shown in the drawings.

Supply and Installation a 15A single switched socket outlet fixed on wall, from the respective consumer unit using 2x2.5mm2 PVC/PVC/CU + 2.5mm2PVC/cu(E) cable drawn through securely fixed concealed PVC conduit shown in the drawings.

The light fittings supplied and installed under this contract shall be in every respect suitable for the intended purpose.

Each fitting shall include bulbs, internal wiring, hanging and fixing material and be complete without any additional item/material being required to make it so.

All control gear of light fittings such as choke, starters, PF Correction Capacitors shall be of European make

The contractor shall obtain consultants and clients approval for the fittings before fixing the fittings in the site

Page 27: Electrical BOQ

8F/13 Bulk Head Lamp- Type A 72 no 3,675.00

HOUSES

8F/14 Bracket Lamp c/w 70W CFL 36 no 3,675.00

8F/15 Pendent Lamp c/w 70W CFL 216 no 2,625.00

8F/1636 no 2,940.00

8F/17 Electrical Bell With Bell Push 36 no 3,675.00

8F/18 Provisional Sum for Lightning Protection System Item

8F/19 Provisional Sum for Telephone and TV Wiring System Item

TO COLLECTION

PROJECT NAME

08

ITEM DESCRIPTIONQTY. UNIT UNIT RATE

ITEMREF.

ELECTRICAL INSTALLATION

COLLECTION

Page No. 8/27

Page No. 8/28

Page No. 8/29

Page No. 8/30

CARRIED TO BILL NO. 8 SUMMARY

600mm ,18W Single fluorescent fitting with Linear Diffuser

BILL OF QUANTITIES

BILL NO.

SPEC. DIV. NO.

Proposed Housing Project for relocation of Under Served Settlements, Angulana

Block-F superstructure

Page 28: Electrical BOQ
Page 29: Electrical BOQ

PAGE NO.

8/27

TOTAL PRICE RUPEES

21,000.00

Page 30: Electrical BOQ

21,000.00

PAGE NO.

8/28

TOTAL PRICE RUPEES

1,968,750.00

294,000.00

3,234,000.00

238,500.00

68,250.00

Page 31: Electrical BOQ

5,803,500.00

PAGE NO.

8/29

TOTAL PRICE RUPEES

945,000.00

208,080.00

Page 32: Electrical BOQ

832,320.00

120,240.00

2,105,640.00

PAGE NO.

8/30

TOTAL PRICE RUPEES

680,400.00

170,100.00

Page 33: Electrical BOQ

264,600.00

132,300.00

567,000.00

105,840.00

132,300.00

2,052,540.00

PAGE NO.

8/31

TOTAL PRICE RUPEES

21,000.00

5,803,500.00

2,105,640.00

2,052,540.00

9,982,680.00

Page 34: Electrical BOQ
Page 35: Electrical BOQ

PROJECT NAME

08

ITEM DESCRIPTIONQTY. UNIT UNIT RATE

ITEMREF.

8F/- ELECTRICAL INSTALLATION

Note :

General

Inspection and testing

8F/01

1 Item 21,000.00

Main Power Supply System

cables

Note :

BILL OF QUANTITIES

BILL NO.

SPEC. DIV. NO.

Proposed Housing Project for relocation of Under Served Settlements, Angulana

Block-G superstructure

All materials, equipments, wiring and workmanship shall confirm to local codes of specifications, B.S Standards, latest I.E.E regulations (17th edition) and Ceylon Electricity Board specifications. Contractor shall investigate the site conditions before submitting their quote

Contractor shall obtain sample approvals from all the items used from CEE-SEC

Contractor shall propose shop drawings/conduit layouts drawings and obtained approval from CEE-SEC before commencing installation

Testing of the complete Electrical Installation and issuing a certificate by a chartered Electrical Engineer, registered with Ceylon Electricity Board.

Rates should include for all necessary cable accessories such as cable ties, Cable Lugs, Glands, identification tags, and accessories All horizontal and vertical Cable trays should be adequately sized to provide 40% spare space.Contractor shall investigate the site conditions and include all the cost involved in point rates given below.

All the Cables quoted below shall be on measure and pay basis. Rates shall include installation of Cable taryas,Cable Ladders, PVC trunking or conduits and accessories where required .

Page 36: Electrical BOQ

TO COLLECTIONPROJECT NAME

08

ITEM DESCRIPTIONQTY. UNIT UNIT RATE

ITEMREF.

8F/02

150 m 13,125.00

8F/03

80 m 3,675.00

8F/04

2000 m 1,470.00

8F/05900 m 265.00

Distribution Boards.

note

note

note

note

COMMON AREA

8F/06 Lift DB 1 no 68,250.00

01 No. 4P 63A MCB 01 No. DP 32A MCB 01 No. 4P 63A,100mA RCCB01 No. DP 40A,30mA RCCB01 No. SP 20A MCB02 Nos.SP 10A MCB

BILL OF QUANTITIES

BILL NO.

SPEC. DIV. NO.

Proposed Housing Project for relocation of Under Served Settlements, Angulana

Block-G superstructure

Supply,Installation & Termination of 4 x 70mm2 XLPE/SWA/PVC/Cu Cable from MSB to Meter Room 01 (For Block C)

Supply,Installation & Termination of 4 x 16mm2 PVC/PVC/Cu + 16mm2 PVC/Cu(E) Cable from G.SDB-2 to Lift DB

Supply,Installation & Termination of 2 x 6mm2 PVC/PVC/Cu Cable from Meter Room-2 to Each House Distribution Board

Supply,Installation & Termination of 6mm2 PVC/Cu Earth Cable from DB to Cu Plate at Electrical Shaft.

All Distribution Boards shall be flush/Surface mounted type Distribution Boards complete with powder coated 1.5 mm thick sheet steel enclosure with lockable doors.

The panel board should have wire numbering and a laminated circuit diagram pasted on the inside surface of the door.

Make of MCCBs and MCBs, etc shall be Merlin Gerin / ABB / Terasaki / Hager or equivalent make approved by the Electrical Engineer.

Manufactures soft drawings should be submitted and aproved by chief electrical engineer before fabrication.

Page 37: Electrical BOQ

01 No. SP 16A MCB

TO COLLECTION

PROJECT NAME

08

ITEM DESCRIPTIONQTY. UNIT UNIT RATE

ITEMREF.

HOUSES

8F/07 DB.H 27 no 26,250.00

01 No. 32A DP MCB01 No. DP 40A,30mA RCCB01 No.SP 16A MCB09 Nos.SP 20A MCB

Wiring for light points, ceiling fans, socket outlets

note

note

COMMON AREA

8F/08

19 no 2,890.00

HOUSES

Flush mounted Powder Coated Steel Lockable Enclosure c/w bus bars and Accessories

BILL OF QUANTITIES

BILL NO.

SPEC. DIV. NO.

Proposed Housing Project for relocation of Under Served Settlements, Angulana

Block-G superstructure

Flush mounted Powder Coated Steel Lockable Enclosure c/w bus bars and Accessories

Rate point wiring shall include for all the conduits, conduit fittings, casings,surface cable trunks, fixing material, switches, wiring and terminations, holders for light fittings and socket outlets for power points. Contractor shall obtain approvals from the Chief Electrical Engineer for above items. Aproved samples should be displayed at the site office.

As a standard of quality for switches and socket outlets, the contractor may use 'CLIPSAL/hager /mk or approved equal'.

Supply and Installation a light point, from the respective consumer unit using 2x1mm2 PVC/PVC/CU + 1.5mm2 PVC/cu(E) cable drawn through securely fixed concealed PVC conduit controlled by a 5A flush switch as shown in the drawings.

Page 38: Electrical BOQ

8F/09

216 no 2,890.00

8F/10

27 no 3,340.00

TO COLLECTION

PROJECT NAME

08

ITEM DESCRIPTIONQTY. UNIT UNIT RATE

ITEMREF.

8F/11

162 no 3,150.00

8F/12

27 no 4,725.00

Light fittings

note

note

note

note

COMMON AREA

Supply and Installation a light point, from the respective consumer unit using 2x1mm2 PVC/PVC/CU cable drawn through securely fixed concealed PVC conduit controlled by a 5A flush switch as shown in the drawings.

Supply and Installation a Bell point, from the respective consumer unit using 2x1mm2 PVC/PVC/CU cable drawn through securely fixed concealed PVC conduit controlled by a Bell push as shown in the drawings.

BILL OF QUANTITIES

BILL NO.

SPEC. DIV. NO.

Proposed Housing Project for relocation of Under Served Settlements, Angulana

Block-G superstructure

Supply and Installation a 5A single switched socket outlet fixed on wall, from the respective consumer unit using 2x1.5mm2 PVC/PVC/CU + 1.5mm2PVC/cu(E) cable drawn through securely fixed concealed PVC conduit shown in the drawings.

Supply and Installation a 15A single switched socket outlet fixed on wall, from the respective consumer unit using 2x2.5mm2 PVC/PVC/CU + 2.5mm2PVC/cu(E) cable drawn through securely fixed concealed PVC conduit shown in the drawings.

The light fittings supplied and installed under this contract shall be in every respect suitable for the intended purpose.

Each fitting shall include bulbs, internal wiring, hanging and fixing material and be complete without any additional item/material being required to make it so.

All control gear of light fittings such as choke, starters, PF Correction Capacitors shall be of European make

The contractor shall obtain consultants and clients approval for the fittings before fixing the fittings in the site

Page 39: Electrical BOQ

8F/13 Bulk Head Lamp- Type A 19 no 3,675.00

HOUSES

8F/14 Bracket Lamp c/w 70W CFL 27 no 3,675.00 .

8F/15 Pendent Lamp c/w 70W CFL 162 no 2,625.00

8F/1627 no 2,940.00

8F/17 Electrical Bell With Bell Push 27 no 3,675.00

8F/18 Provisional Sum for Lightning Protection System Item

8F/19 Provisional Sum for Telephone and TV Wiring System Item

TO COLLECTION

PROJECT NAME

08

ITEM DESCRIPTIONQTY. UNIT UNIT RATE

ITEMREF.

ELECTRICAL INSTALLATION

COLLECTION

Page No. 8/27

Page No. 8/28

Page No. 8/29

Page No. 8/30

CARRIED TO BILL NO. 8 SUMMARY

600mm ,18W Single fluorescent fitting with Linear Diffuser

BILL OF QUANTITIES

BILL NO.

SPEC. DIV. NO.

Proposed Housing Project for relocation of Under Served Settlements, Angulana

Block-G superstructure

Page 40: Electrical BOQ
Page 41: Electrical BOQ

PAGE NO.

8/27

TOTAL PRICE RUPEES

21,000.00

Page 42: Electrical BOQ

21,000.00

PAGE NO.

8/28

TOTAL PRICE RUPEES

1,968,750.00

294,000.00

2,940,000.00

238,500.00

68,250.00

Page 43: Electrical BOQ

5,509,500.00

PAGE NO.

8/29

TOTAL PRICE RUPEES

708,750.00

54,910.00

Page 44: Electrical BOQ

624,240.00

90,180.00

1,478,080.00

PAGE NO.

8/30

TOTAL PRICE RUPEES

510,300.00

127,575.00

Page 45: Electrical BOQ

69,825.00

99,225.00

425,250.00

79,380.00

99,225.00

1,410,780.00

PAGE NO.

8/31

TOTAL PRICE RUPEES

21,000.00

5,509,500.00

1,478,080.00

1,410,780.00

8,419,360.00

Page 46: Electrical BOQ