The closed loop system at ISR

9
The closed loop system at ISR We moved the system at ISR in January. Preliminary tests has been done in order to verify the possible use in the “ISR conditions”: 1.Total flow of 150-200 l/h 2.Connect and disconect frequently the RPC from the gas system The closed loop worked at the GIF for many months with a total flow of 40 l/h and a fresh mixture input of 2 l/h (5% of the total flow) CMS week 14 March 2005 Roberto Guida

description

The closed loop system at ISR. The closed loop worked at the GIF for many months with a total flow of 40 l/h and a fresh mixture input of 2 l/h (5% of the total flow). We moved the system at ISR in January . - PowerPoint PPT Presentation

Transcript of The closed loop system at ISR

Page 1: The closed loop system at ISR

The closed loop system at ISR

We moved the system at ISR in January.Preliminary tests has been done in order to verify the

possible use in the “ISR conditions”:

1. Total flow of 150-200 l/h2. Connect and disconect frequently the RPC from the gas

system

The closed loop worked at the GIF for many months with a total flow of 40 l/h and a fresh mixture input of 2 l/h (5% of the total flow)

CMS week 14 March 2005Roberto Guida

Page 2: The closed loop system at ISR

Total flow of 150-200 l/h

• The system was tested succesfully with an argon bootle (short test: only few hours)

• During this test 4 RPC were connected

• A total flow of 200 l/h was reaced with an input flow of 10 l/h (5% of the total flow)

Page 3: The closed loop system at ISR

Connect and disconect frequently the RPC from the gas system

• The RPCs under test change every 2-3 weeks

• It must be avoided the connection of an RPC full of air to the closed loop system (contamination of all the circuit)

• It is impossible to stop the gas flow (the system is sensible to pressure variation)

Page 4: The closed loop system at ISR

Project• We have forseen an open loop line for the

first connection of an RPC and two three ways valves (for each gas line) for the commutation between the open loop to the closed loop

• We have already tested this solution with two channel connected to the closed loop and two valves per channel for the commutation

Page 5: The closed loop system at ISR

Input Open Loop

Output Open Loop

Closed Loop Rack

Output Closed Loop

Input Closed Loop

Distrib. Rack Input Part

Distrib. Rack Output Part

Page 6: The closed loop system at ISR

RPC

bubblers

Three ways valve

Rotameters

Ch 1 Ch 2

Cl,Op, Cl,Cl, Op, Op, Op, Cl,

Flux contr. Flux contr.

Legend

Page 7: The closed loop system at ISR

Status of the system• Test of the three ways valve OK• Test of the connection to the general input and output

lines OK• 3 new lines for the closed loop (input and output) OK

1 new line for the open loop (input and output) OK

Each line is about 100 mt long • Construction of the commutation pannels (between

closed and open loop) OK

Page 8: The closed loop system at ISR

• Construction of the commutation pannels (between closed and open loop) OK

Input valves

output valves

Bubblers for the open line

10 channels

Page 9: The closed loop system at ISR

• Integration between the present system and the commutation pannels Wednesday 16th March

• Development of a system for switch off the HV in case of a stop of the closed loop

• Test of the final system