VRV III to Upload

download VRV III to Upload

of 6

Transcript of VRV III to Upload

  • 7/28/2019 VRV III to Upload

    1/6

    Table of Contents

    1. Introduction of the Project

    2. Design of New BCP

    3. Rationale for using Variable Refrigerant Volume (VRV)

    4. Simplifies installation benefits of the VRV System

    4.1 Direct Cost Saving with VRV

    4.2 Low Cost of VRV

    5. Economic Benefits

    5.1 Conserves space

    5.2 Design flexibility

    5.3 Quality Benefits

    6. Public Health Benefits

    7. Environmental Benefits

    7.1 Air quality Benefit

    7.2 Noise Benefit

    8. Conclusion

    9. References

    A2 sized Poster

    1 of 6

  • 7/28/2019 VRV III to Upload

    2/6

    1. Introduction of the Project

    The HKSAR Government and Shenzhen Municipal Peoples Government both

    have recognized the need to enhance cross-boundary transport infrastructure for

    long-term economic growth and further regional co-operation. On 18 September

    2008, the two Governments jointly announced the implementation of the new

    boundary control point (BCP) at Liantang / Heung Yuen Wai. Commencing

    operation of the new BCP will be in 2018.

    We are appointed by the HKSAR government to apply innovative construction

    technology and idea on efficient air condition system for the terminal building.

    2. Design of New BCP

    A two-storey design is adopted to minimize land requirement. Facilities for goods

    vehicles and public transport interchange will be located on the ground floor. The

    upper floor will serve passengers, private cars and coaches. The size of upper

    floor is only one-fourth of the total area of the lower floor (about 4.6 hectares).

    3. Rationale for using Variable Refrigerant Volume (VRV)

    Variable Refrigerant Volume (VRV) permits the system to automatically adjust

    itself to the air conditioning load demands so that the system is energy efficient in

    operation. VRV system air conditions each individual location. Precise level

    control is possible that reacts to the exact conditions in each room. Individual

    control promotes a far more economical and efficient system.

    There has among the many of its successful projects and accolades of a satisfied

    clientele shown as below:

    The Embassy of Peoples Republic of China

    The High Commission of Canada

    J M Mall in Tanzania

    The Tanzania Revenue Authority

    The High Commission of Great Britain

    2 of 6

  • 7/28/2019 VRV III to Upload

    3/6

    The technologically advanced VRV III-C inverter controlled heat pump system,

    designed especially for installation in cold climates. It provides highly efficient

    heating in outdoor temperatures as low as -25 C that it is very suitable for this

    new BCP.

    4. Simplifies installation benefits of the VRV System

    Outdoor air cooled condensing units are easily located on roof tops of the building

    or located on each floor. Therefore no need for a separate machine or equipment

    room required for saving more place.

    Varieties of VRV Indoor Fan coil units are available to suit the requirements in a

    premise and to meet the clients' special needs. Many mounted type models are

    available in various cooling capacities.

    Installation of VRV System can minimize to reduce the builders and electrical

    works. It is both suited for use in new buildings and in the restoration of existing

    buildings for future. No major modifications are necessary for its installation.

    VRV has the optional facility to provide a centralized control to operation and

    control by individual controllers. Centralized control system can be operated from

    a convenient location in the building. It has for monitoring the performance of

    units in individual area. It provides to switch ON/OFF the units at any desired

    locations at any given time without entering the particular area. No need to have a

    specially trained team of technicians to operate and control the system. Good

    facility to indicate nature of fault for taking a prompt action to rectify the fault.

    Inspection after installation is straightforward.

    The indoor unit's cooling operation can be controlled to maintain desired

    temperature in any location at any environment change of needs and preferences.

    The lightweight, compact units can be transported using a regular lift. The pipes

    are few in number and making design plan layout simpler.

    3 of 6

  • 7/28/2019 VRV III to Upload

    4/6

    4.1 Direct Cost Saving with VRV suitability to Present Day Condition

    This system permits modular operation where load can be gradually transferred to

    the standby generator, and a generator with the capacity to meet normal power

    loads will meet the requirements. There is cost saving on both the sizing and

    running cost of the standby generator.

    4.2 Low Cost of VRV

    In a VRV system, the Builders and electric works required are minimal and simple

    so that cost much less than in other systems of air conditioning. Therefore the

    overall system cost in VRV system including that of builders and electrical works

    will compare very favorably with the system cost of other types of air

    conditioning. At the same time, the VRV system offers several advantages over

    other systems of air conditioning.

    5. Economic Benefits

    Individual control promotes a far more economical and efficient system. Saves

    energy can using the HRV for ventilation dramatically boosts energy efficiency.

    The VRV delivers highly efficient performance, contributing to high energy

    savings.

    5.1 Conserves space

    Space efficiency is enhanced by the compact size of the individual units, the long

    maximum piping length, and the ability to realize a large scale air conditioning

    system with a single piping circuit.

    5.2 Design flexibility

    The extended maximum piping length gives more flexibility when designing.

    Change of layout can easily because the indoor units capacity can be up to 200%

    that of the outdoor units. New compressor technology eliminates the need for

    4 of 6

  • 7/28/2019 VRV III to Upload

    5/6

    piping calculation to short the time needed for design. No effect on the design of

    the building interior when the outdoor units can be installed on the roof.

    5.3 Quality Benefits

    The self-diagnostic system identifies problems quickly and accurately. The Auto

    Restart function ensures that operation is restored with the previous settings even

    if the power has been shut off. Units are controlled in each individual area so that

    local malfunctions do not cause the entire system to shut down.

    6. Public Health Benefits

    It operates over a broad temperature range in heating to extend from 15C to

    20C to suitable for any weather.

    7. Environmental Benefits

    A recent trend rapidly gaining popularity is required for air treatment as well as air

    conditioning. VRV Outdoor unit can combine fresh air treatment and air

    conditioning that it adjusts the temperature of air from outdoors using a fixed

    discharge temperature control to praise for their compactness, energy conservation

    and extensive operation range of outdoor temperatures. It provides higher

    enthalpy efficiency and improved external static pressure offers more flexibility

    for installation.

    7.1 Air quality Benefit

    The system equipped with a DX-coil and a humidifier to provide further advanced

    features, such as temperature adjustment to suit conditions indoors and to prevent

    cold air from blowing on people directly during heating operation.

    7.2 Noise Benefit

    Low operation sound level decreases the noise pollution by using good silencer.

    5 of 6

  • 7/28/2019 VRV III to Upload

    6/6

    Units are designed to operate quietly and equipped with a function for silent

    operation especially at night.8. Conclusion

    A VRV system provides considerable savings on energy, costs, and space

    requirements. Its innovative inverter technology ensures the variety of

    performance required by building owners in every stage of operation. And the

    unique piping system and compact, lightweight unit design give flexibility in

    system planning and quick and easy installation.

    In future, new solar air conditioning refers to any air conditioning (cooling)system that uses solar power. The U.S. Energy Independence and Security Act of

    2007 created 2008-2012 research funds for a new solar air conditioning

    development program to develop and demonstrate multiple new technology

    innovations and mass productioneconomies of scale. Solar air conditioning will

    become important role in zero-energy and energy-plus buildings design.

    Our VRV air conditioning units will be converted to solar power to save on energy

    costs. There will some other sustainable ways of cooling the air using new

    technologies that provide some exciting possibilities for the future. As our world

    transforms and begins to make the use of clean and renewable energy sources a

    priority, we will see more of these kinds of innovative solutions!

    9. Reference:

    1) http://www.daikintanzania.com/vrv.asp

    2) http://www.daikin.com.hk/eng/products/vrv_whats_eng.php3) http://www.daikin.com.hk/pdf/VRV%20III%20PCV0915A.pdf

    4) http://www.go-green-solar-energy.com/solar-air-conditioning.html

    6 of 6

    http://en.wikipedia.org/wiki/Air_conditioninghttp://en.wikipedia.org/wiki/Air_conditioninghttp://en.wikipedia.org/wiki/Solar_powerhttp://en.wikipedia.org/wiki/Solar_powerhttp://en.wikipedia.org/wiki/Energy_Independence_and_Security_Acthttp://en.wikipedia.org/wiki/Mass_productionhttp://en.wikipedia.org/wiki/Mass_productionhttp://en.wikipedia.org/wiki/Economies_of_scalehttp://en.wikipedia.org/wiki/Economies_of_scalehttp://www.go-green-solar-energy.com/solar-air-conditioning.html#ixzz2CqD17vr2http://en.wikipedia.org/wiki/Solar_powerhttp://en.wikipedia.org/wiki/Energy_Independence_and_Security_Acthttp://en.wikipedia.org/wiki/Mass_productionhttp://en.wikipedia.org/wiki/Economies_of_scalehttp://www.go-green-solar-energy.com/solar-air-conditioning.html#ixzz2CqD17vr2http://en.wikipedia.org/wiki/Air_conditioning