VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction...

94
VRV catalogue 2015 Redefining efficiency in climate control

Transcript of VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction...

Page 1: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

FSCCarbon

Balanced Paper

VRV catalogue 2015

Redefining efficiency in climate control

Daikin U

KVRV catalogue 2015

Daikin products are distributed by:The present catalogue is drawn up by way of information only and does

not constitute an offer binding upon Daikin UK. Daikin UK has compiled the

content of this catalogue to the best of its knowledge. No express or implied

warranty is given for the completeness, accuracy, reliability or fitness for

particular purpose of its content and the products and services presented

therein. Specifications are subject to change without prior notice. Daikin UK

explicitly rejects any liability for any direct or indirect damage, in the broadest

sense, arising from or related to the use and/or interpretation of this catalogue.

All content is copyrighted by Daikin UK.

Daikin Airconditioning UK Limited The Heights Brooklands Weybridge Surrey KT13 0NY Tel 0845 6419000 Fax 0845 6419009 daikin.co.uk

UKE

PCEN

15-9

88 /

03.

15 /

Des

ignH

Q. C

opyr

ight

201

5 D

aiki

nPr

inte

d in

the

UK

on F

SC c

ertif

ied

pape

r fro

m s

usta

inab

le s

ourc

es.

Scotland Region

0845 641 9330

Northern Region

0845 641 9340

Midlands Region

0845 641 9370

Western Region

0845 641 9320

North London

0845 641 9360

South London

0845 641 9355

Daikin units comply with the European regulations that guarantee the safety of the product.

For Air curtains, VAMS and Applied products visit www.eca.gov.uk/etlFor Split, Sky Air and VRV units check and print your own eligibility statement for ECA at www.daikin.co.uk/eca

Page 2: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows
Page 3: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

1VRV catalogue 2015

Redefining efficiency in climate control

Intr

oduc

tion

App

licat

ions

Hea

t Rec

over

yH

eat P

ump

Repl

acem

ent

Min

i Hea

t Pum

pW

ater

coo

led

Cont

rols

Indo

or u

nits

Vent

ilatio

nPo

rtfo

lio

Introduction to VRV

VRV IV total solutions 2

VRV Heat Recovery 3

Redefining efficiency 4-5

Design efficiency 6-9Online design software

Installation efficiency 10-11

Operation efficiency 12-15

Outdoor units Heat Recovery VRV

Heat Recovery systems 24-28

Heat Pump VRV

Heat Pump systems 30-36

Replacement VRV

Replacement VRV 38-45

Mini Heat Pump VRV

Mini Heat Pump VRV 46-49VRV IV range

Water cooled VRV

Water cooled VRV 50-52Full Multi BS box capabilities

Applications

Retail 16-17

Workplace 18-19

Hospitality 20-21

Public buildings 22-23

Controls

Control solutions 54-61Intelligent touch Manager II

Indoor units

Fan coils 62-77Redesigned fan coils

Hot water production Hydroboxes 78-79

Air curtains 80-81

Ventilation

Heat Recovery Ventilation 82-85

Air Handling Unit applications 86-87Extended range for higher capacity AHU’s & new control method

Product portfolio

Outdoor units 88-89

Indoor units 90-91

Hot water 90-91

NEW

NEW

NEW

NEW

NEW

NEW

Page 4: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

2 VRV catalogue 2015

VRV IV total solutions to maximise energy efficiency

Energy in buildings

In many commercial buildings, there are energy balance requirements. Energy is needed for both heating and cooling, for hot water and refrigeration, as well as for ventilation. Typically, these functions are powered and operated by separate systems and all of the energy collected by these systems is rejected into the outside air.

But with a VRV solution, many of these building HVAC services can be operated by a single system, which can recover waste energy and reuse it to provide heating or cooling capacity elsewhere within the building.

Understanding whole building needs

Heating, cooling, refrigeration and air conditioning account for around 40-50% of a typical building’s energy usage. Most buildings rely mainly on primary energy from energy supplier.

However, by understanding the whole building’s heating and cooling needs at the outset, an integrated climate control solution can be delivered that offers much higher energy efficiency levels, thus reducing the energy consumption and carbon impact of a building.

Daikin has the technology, and all the products, to deliver the definitive answer: a total solution that redefines efficiency.

Page 5: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

3VRV catalogue 2015

Intr

oduc

tion

VRV Heat Recovery heating and cooling solutions

Air curtainsBiddle air curtains are the ideal solution for retailers

and consultants to combat the issue of climate

separation across their outlet or office doorway. Using

a combination of rectifier technology, air velocity and

temperature control, they deliver greater comfort to

staff and customers alike, all year round, in all weathers.

AHU and VAM connectionsAir handling units provide bulk air movement around

a building, to provide ventilation and maintain indoor

air quality. By using a VRV system to connect directly

via a refrigerant circuit, the VRV IV systems are able

to provide heating and cooling to air handling units

to reduce or eliminate the increased loads on the air

conditioning system due to fresh air.

Hot waterThe waste heat from offices,

comms rooms, open reception

areas, or even industrial

applications can be re-used

to provide, not just sanitary

hot water, but also underfloor

heating or water for an Air

handling unit (AHU).

Page 6: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

4 VRV catalogue 2015

Redefining efficiency of VRV technology

For climate control in all types of buildings, the mission to

achieve ever greater efficiency is relentless. Over time, progress

is typically made in marginal refinements of technological

design or operational control. Until now!

360°efficiency

Page 7: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

5VRV catalogue 2015

Intr

oduc

tion

Today, Daikin’s unique VRV IV Heat Recovery technology completely

redefines efficiency – of design, installation and operation.

VRV IV + =HEATrecovery

FASTdesign

Design efficiency> Widest and flexible range of design options

> Unlimited unused ports

> 16kW fan coil with NO capacity loss

> No pump down required when adding fan coils * Accessory required

QUICKinstallation

Installation efficiency> New multi BS boxes 4, 6, 8, 10, 12, 16 port

> Single BS box

> Lighter, smaller, quieter than any similar system

> Increased capacity per port

MOREfree heat

Operational efficiency> Variable refrigerant temperature

> New compressor

> 3 pipe advantage

> New coil design

Variable Refrigerant Volume [VRV] was first developed by Daikin over 30 years ago.

This game-changing innovation revolutionised heating and cooling, providing the ability to operate different climate control settings simultaneously in various areas of a building.

By circulating only the volume of refrigerant required at any given time to meet the capacity demand, VRV offered two key benefits: reduced energy consumption and greater control for building occupants.

Since its introduction, Daikin has led the way in taking this technology to new levels of efficiency, comfort and control.

Now Daikin has completely re-designed this technology to create our market-leading climate control solution: VRV IV Heat Recovery.

The result is over 30% more efficient than previous systems.

Page 8: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

6 VRV catalogue 2015

Real efficiency of design takes into account the lifetime of a

system, not just today’s known requirements. A building’s tenants,

uses and internal layouts may change – so its HVACR system may

need to adapt.

Redefining efficiency in design

Build in future flexibility with Multi-BS boxes

A change of tenant or building usage typically requires substantial changes to branch selector (BS) boxes and pipework. BS boxes usually have a limited number of unused fan coil connections. But with Daikin’s new multi-branch selector boxes, that restriction no longer applies.

For example, a single fan coil could be attached to a 10-way box, leaving 9 ports unused for future needs. Each of those vacant ports could later be used for 14kW fan coils, or to serve the high demand of a communications room.

There should be no need to fit different or additional BS boxes. Only the pipe work needs to be changed in order to reposition fan coils for the new configuration.

However, Daikin continues to offer single BS boxes, so a dedicated box can easily be added to the main pipework, if required.

Reconfigured layout with partitioned offices CAT B fit out: Reconfigured layout with multiple cellular offices, meeting room and comms room. 100kW cooling load. 22 fan coils Two multi-boxes: one now with 9 connections (other still with 6 connections)

System designers can now build-in flexibility for future

re-engineering, without compromising operating costs, energy

efficiency or environmental performance in years to come.

How Cat B fit outs are made simple EXAMPLE: Whole floor in multi-storey office block

Original open plan layout CAT A fit out: Open plan. 100kW cooling load. 24 fan coils. One separated zone (access area –stairwell)Two multi-boxes, each with 6 connections plus unused ports

BS boxes

Fan coils

BS boxes

Fan coils

Page 9: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

7VRV catalogue 2015

Intr

oduc

tion

VRV Xpressquick design and quotation tool

VRV Xpress is a software tool that allows you to create professional

designs and quotations on-the-spot for a Daikin VRV System in

just six simple steps.

1 Select indoor units

2 Connect outdoor units to indoor units

3 Automatic generation of piping diagram with joints

4 Automatic generation of wiring diagram

5 Selection of possible centralised control systems

6 Visualise result in MS Word, MS Excel and AutoCAD

VRV Xpress is widely accepted as the most comprehensive yet simple VRV design software available, allowing you to design systems for peak loads accurately and ensuring your system will always meet the design capacity, giving you peace of mind that your clients’ cooling and heating expectations are met.

New for 2015 – VRV Xpress is going online

A new online version will be available from Summer 2015 that enables the creation, editing and management of VRV design projects across all web enabled devices (Tablet, PC, Mac) so your projects will be accessible from anywhere.

VRV Xpress online incorporates all of the latest Xpress functions in a new more user friendly way. Further details will follow.

Page 10: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

8 VRV catalogue 2015

Advanced IES modelling capabilities

To bring advanced VRV Heat Recovery modelling capabilities

to the market, Integrated Environmental Solutions (IES) has

partnered with Daikin UK to integrate the Daikin Dynamic VRV

Systems Sizing Tool within the IES Virtual Environment (IESVE).

This software tool enables architects and engineers to accurately establish the performance of these state of the art systems within their building project.

Users can automatically size the system and select the correct VRV indoor and outdoor unit model-number based on the buildings heating and cooling loads. Full thermal simulations then reveal annual loads, power input and efficiencies.

The tool allows users to compare alternative configurations so that they can easily evaluate the best option to maximise energy efficiency and lower building energy use.

The software can be used with version VE6.5 onwards and covers the whole Daikin VRV range.

Page 11: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

9VRV catalogue 2015

Intr

oduc

tion

Sound levels in buildings are a major factor in occupant comfort. We have made dramatic reductions in the sound levels of our BS boxes with the introduction of new technology so you can be confident in achieving your clients’ expectations.

These reductions have been made possible by completely redesigning the expansion valves and carefully refining and testing the control logic to deliver the lightest, smallest, most efficient and quietest range of Branch Selector boxes available on the market today.

Branch Selector Boxes designed for low sound levels

The Daikin 4 way multi box offers a sound reduction of 6.5 dBA when compared against other manufacturers under normal operating conditions. It also offers a sound reduction of 13.5 dBA (sound pressure when changing over from one mode to another) when compared with previous models.

Audibly better

45

40

35

30

25

20

Soun

d pr

essu

re >

dBA

Previous version New VRV IV BS Boxes

Stable operation

During changeover

With additional countermeasures sound pressure levels of 25 dBA can be achieved. Daikin do not recommend BS box installations within bedrooms.

Intr

oduc

tion

Page 12: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

10 VRV catalogue 2015

Redefining efficiency in installationFor installers, efficiency is all about time and profitability:

the time taken to fit and commission systems, meet project

deadlines and avoid delays due to unexpected complexity or

changing conditions.

Efficiency in installation is pivotal to competitiveness in project tenders. Ultimately, it can

also be the difference between profit and loss on the job.

The new Daikin three-pipe VRV IV Heat Recovery system takes no longer to install than

a two-pipe system. In fact, our latest technology is designed to make installation faster,

easier and more flexible than ever before.

Smaller Multi-Branch Selector Boxes [BS]

To make system fitting easier for installers, our range now includes 4, 6, 8, 10, 12 and 16-way BS boxes. Unlike other manufacturers’ multi-boxes, these do not require complex separators inside. Accordingly, all Daikin multi-boxes are at least 30% smaller – and our 4-way and 8-way boxes are actually half the size of other manufacturers’ equivalents.

A single BS box is also available if required for a remote area requiring independent control of heating and cooling [EXAMPLES: comms room, or a newly-added enclosed office].

All Daikin multi-boxes will fit comfortably into a 300mm ceiling. They are also quieter and up to 32% lighter than those of other manufacturers. Unlike other manufacturers’ multi-boxes, each port can be connected to a 14kW fan without any loss of cooling capacity. Those other multi-boxes are also subject to a maximum 8kW fan coil on each port. So each Daikin BS multi-box can handle 75% extra capacity.

Easier commissioning and servicing

Daikin VRV IV technology includes advanced software to simplify system commissioning and servicing as well as multi-site commissioning and control of installed systems.

The VRV configurator incorporates a graphical interface so that settings can be pre-prepared off-site for high-speed uploading on site. Among other benefits, this reduces the time required on a roof to configure outdoor units, as well as reducing set-up errors that would otherwise require repeat visits to site.

In addition, the software allows engineers to check systems, evaluate operational data and identify any errors.

No. of Connections

Physical Size (m3) Daikin Box ReductionDaikin Other

1 0.262 N/A N/A

4 0.474 0.957 50%

5 0.743 0.957 22%

6 0.743 0.957 22%

8 0.743 1.422 48%

10 1.051 1.422 26%

12 1.051 1.422 26%

16 1.358 1.422 5%

Page 13: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

11VRV catalogue 2015

Intr

oduc

tion

> Saves time on commissioning

> Manages multiple systems in exactly the same way

> Makes it easy to retrieve initial system settings

Simplified commissioning

The VRV configurator is an advanced software solution for easy system configuration and commissioning:

> Less time is required on the roof configuring the outdoor unit

> Multiple systems at different sites can be managed in exactly the same way, thus offering simplified commissioning for key accounts

> Initial settings on the outdoor unit can be easily retrieved

Simplified servicing

Outdoor unit display makes it quick and easy on-site to adjust settings, check basic functions and read out errors. The 7-segment indicator saves time via:

> Easy-to-read error report> Indication of standard service parameters to

quickly check basic functions > Clear menu for quick and easy servicing on-site

Simplified commissioning

Retrieve initial system settings

VRV

configurator software

Intr

oduc

tion

Page 14: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

12 VRV catalogue 2015

At the core of this technological breakthrough is Variable

Refrigerant Temperature [VRT]. New generation VRV doesn’t just

control the amount of refrigerant in the system; it also controls

the temperature of that refrigerant.

Totally redesigned with Variable Refrigerant Temperature [VRT]

This means the evaporating and condensing temperatures can be tailored precisely within an HVAC system to achieve the optimum balance between comfort and efficiency.

The system adjusts intelligently to weather variations and real-time working situations, as the load requirement fluctuates during the day and within individual zones of the building.

In effect, it delivers a perfectly controlled interior climate without wasting energy.

Multi-stage heat recovery unit

> Indoor heat recovery coil on four sides: 50% more surface area for heat exchange

> Heating and cooling portions variable according to demand rather than fixed sections

> Continuous heating: warm air still being delivered even during outdoor unit defrost

> No cold draughts: no dip in comfort levels

> Immediate return to full capacity after defrost

Redefining efficiency in operation

Page 15: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

Intr

oduc

tion

Page 16: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

14 VRV catalogue 2015

Market leading operational efficiency

VRV IV Efficiency VRF Efficiency

Operational efficiency is much more than a nominal measure of energy consumption.

It is now measured in the real-life application of technology throughout the changing

seasons and the varying demands of building usage across each year.

VRV IV HR compared with a standard VRF* system *Variable Refrigerant Flow

Building type: Multi-storey office block Time: Summer

In this example, the differing energy consumptions are show in a multi-storey office block with reception area, cellular and open plan offices, meeting rooms, washrooms and communications room.

The building is routinely occupied from 08.00-19.00, Monday-Friday and generally unoccupied outside these hours.

The enhanced capabilities of our new systems mean that we are already well-placed for imminent changes in how efficiency will be rated in future.

From 2016, VRV systems will no longer be rated on the basis of a single measure, but on their performance over a typical year.

Page 17: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

15VRV catalogue 2015

Intr

oduc

tion

Daikin’s new generation VRV IV heat recovery extends and enhances the capabilities of VRV technology – giving greater scope for smarter use of energy and a more intelligent response to each individual building’s HVAC needs.

Page 18: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

16 VRV catalogue 2015

In the current commercial environment, retailers are under pressure

to reduce both store development and running costs. Legislation

adds further financial pressure, with initiatives such as the Carbon

Reduction Commitment Energy Efficiency Scheme meaning that

larger retailers need to improve energy efficiency dramatically,

or face stringent penalties.

Reducing

retail costs

Affordable, energy efficient solutions are vital to minimise lifetime costs, while ensuring compliance with the latest regulations.According to the Carbon Trust, the retail sector is responsible for around 21 million tonnes of CO

2 emissions per year. The retail

sector could cut its total spend on heating and cooling by a massive £560 million annually by making energy savings of 20%.

The Carbon Trust also estimates that heating and hot water account for 60% of a retailer’s energy bills. Typically, retailers with air conditioning systems have double the energy consumption and association carbon emissions compared with those that don’t. This need not be the case if an energy efficient solution is implemented.

VRV solutions offer:

> Energy saving inverter heat pump technology, delivering COP’s of up to 8 in mixed mode operation

> Individual control of each indoor unit > A customisable solution using ‘variable refrigerant temperature’

to achieve the highest seasonal efficiency > The highest standards of heating comfort, thanks to continuous

heating during defrost> Flexible installation: the heat pump can be installed outdoors to

maximise commercial space internally or can be installed indoors so there is no visual impact and low noise.

Versatile climate control

Climate control is key to creating a comfortable browsing environment in store. However a uniform temperature across the store is often not the best solution. Retailers need the flexibility to control multiple indoor units individually, so that the different areas of a shop – such as the shop floor, storage and staff areas – can be set at different temperatures in order to provide the highest levels of comfort for staff and customers.

Energy efficient VRV systems help to improve comfort levels, while allowing each area to maintain its set temperature. Micro processors balance the system’s performance with the building’s requirements to enable its compressors to operate down to power levels 40 to 45% lower than more conventional systems, thus reducing running costs and carbon emissions.

Page 19: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

17VRV catalogue 2015

App

licat

ions

Case studyPorsche Centre, Colchester

Extending a car showroom ahead of the launch of the sporty Macan Turbo SUV meant the Porsche Centre in Colchester needed an equally standard-setting heating and ventilation system to provide a comfortable environment for customers and staff.

Echoing the Macan’s principles of performance, efficiency and comfort the heating and ventilation system now serving the enlarged display area – created by converting the former workshop – is Daikin’s range-topping VRV IV heat pump and a VAM ventilation unit.

The new heat pump operates alongside an earlier VRV III heat recovery system, which serves the existing offices.

The ceiling units installed at Colchester are ideal for use in shops and medium sized offices, because they can be used with ducts of varying lengths. They consume 20% less electricity than similar earlier models, thanks to a new DC fan.

The Daikin VAM heat reclaim ventilation (HRV) unit, also mounted in the ceiling, modulates the temperature and humidity of incoming fresh air to match the indoor conditions. This provides a balance between indoor and outdoor temperatures, significantly reducing the cooling or heating load on the air conditioning system while ensuring frequent air-changes.

> 1 VRV IV heat pump (20hp)> 6 Medium static pressure concealed ceiling units

with inverter fan(10kW and 12.5kW)> 1 VAM heat recovery ventilation unit> Daikin Intelligent Touch controller

Case studyThe Range, Warrington

The Range is a nationwide retail chain offering a variety of mid-priced goods for the home – DIY, homewares, furniture, lighting, arts and crafts and garden products.

The Daikin systems serving The Range’s 7,800m2 store in Warrington provide a complete solution for climate control and hot water. Seven VRV IV heat pump condensing units and 71 self-cleaning Roundflow Cassettes heat or cool the shop floor in response to commands from the Daikin RTD-20 retail control system. A VRV III heat recovery system and standard fan coils provide simultaneous heating and cooling in the offices and other back-of-house facilities – as well as hot water.

The VRV IV heat pump is 28% more efficient than earlier models, as its Variable Refrigerant Temperature technology adjusts to provide optimal seasonal efficiency at all times. VRV IV also qualifies for ECA approval.

“ We were very happy to work with Daikin UK to incorporate one of the latest fully integrated renewable systems, allowing The Range at Warrington to have a fully controllable system with operation flexibility according to requirements.”

Brad Hurter, CDS Group

> 7 VRV IV heat pump condensing units with continuous heating

> 71 Self-cleaning Roundflow Cassettes> 1 VRV III heat recovery condensing unit> VRV fan coil units> Hydrobox> 200-litre DHW tank> VAM heat recovery ventilation unit> RTD-20 intelligent retail control system> I-Touch Manager

Page 20: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

18 VRV catalogue 2015

Efficient building and facilities management are key to minimising

operational costs within medium-sized offices and large

office complexes.

Efficiency in the

workplace

Heating, air conditioning, hot water and ventilation are all significant areas of energy consumption. But neither the commercial climate, nor the current legislative framework, will tolerate wasted resources. Responsible businesses are seeking new and innovative ways to rein in their running costs and carbon emissions.

Daikin provides total climate management solutions that put building managers in complete control of the indoor climate. VRV solutions are ideal for medium to large buildings, helping installers, specifiers and building managers to:

> Dramatically reduce the cost of hot water and heating by re-using heat recovered from areas requiring cooling

> Ensure controllable comfort, by simultaneously heating spaces while cooling others

> Choose outdoor heat pump installation to maximise commercial space internally or indoor installation to minimise the visual impact and noise externally.

A healthier office atmosphereVRV’s integrated capabilities mean that ventilation and air conditioning can be combined in one system, with air filtration ensuring a steady supply of clean air. Energy waste is minimised by recovering heat from the stale air expelled from buildings and using it to heat incoming air virtually for free.

Cutting the cost of hot waterBy using VRV’s heat pump technology to recover heat from areas requiring cooling, reclaimed heat can be used to produce hot water for sinks, under floor heating, showers and radiators. The entire system can be connected to solar panels to provide additional solar thermal energy for hot water production.

Centralised controls for officesManaging comfort settings and energy consumption is easy with VRV systems, which offer user-friendly controls that can be integrated with other building services such as lighting and blinds.

> Easy to use touch screen> Many energy saving functions available including

movement sensors, controllers with evening and holiday schedules

> Energy consumption can be set per indoor unit> Monitoring and control available for up to

128 indoor units> Online monitoring and control available for

multiple buildings > Controls can be integrated with other systems

e.g. blinds, lights etc.> Energy costs can be managed and divided among

multiple tenants.

Page 21: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

19VRV catalogue 2015

App

licat

ions

Case studyVelocity, Brooklands

Energy efficient heat recovery air conditioning from Daikin UK enhances the ‘green’ credentials of a stylish office development designed to attract ‘head office’ tenants at Brooklands, in Surrey.

With their Breeam ‘excellent’ rating and low B ratings for energy performance, the two buildings in the 9,885m2 Velocity development sport a range of environment friendly systems to create a top-class workplace that is economically attractive to both landlord and tenants.

Named to evoke memories of Brooklands’ aviation and motor racing past, the five-storey Velocity buildings symbolise streamlined speed and their systems reflect the best in technology.

Solar shading on the south-facing aspects reduces solar gain, while rooftop photovoltaic and solar thermal arrays provide renewable alternatives for some of the buildings’ energy needs.

Daikin UK’s VRV III heat recovery systems were specified for Velocity’s office heating and cooling needs, giving the buildings a total of 358hp of air conditioning power.

The entire air conditioning system is controlled automatically by the Building Energy Management System, which is programmed to keep indoor temperatures at 22-23°C all year.

“ Daikin is a personal preference of mine. They were first with VRV and have led the field with improvements to the concept. Their systems are very reliable.”

Peter Wright, Wright Engineering Consultants

> 28 VRV III heat recovery compact condensing units> 2 VRV III heat pumps> 256 ducted fan coil units

Case studyFlow, Staines-upon-Thames

A structural extension to suit a major tenant moving into a high efficiency new-build office development beside the River Thames provided an ideal opportunity to compare the performance of two generations of Daikin VRV air conditioning systems.

The original 6,709m2 development at Staines-upon-Thames consisted of two buildings – Flow 1 and Flow 2. Respectively four and three storeys, they were built speculatively and Category A fitted for possible occupation by up to seven individual tenants after completion in 2013. Both buildings have BREEAM ‘excellent’ ratings – exceeding the original aim of ‘very good’ through increased on-site efficiency.

Complementing the buildings’ other efficiencies, seven separate, independently controlled Daikin VRV III heat recovery systems with outdoor units of 20hp to 38hp were installed.

However, the whole development has been let to an American software company on a 10-year lease and contractors have added walk-though access between the first and second floors of the buildings.

The two-storey link adds another 173m2 of usable space, requiring two additional fan coil units on each level, served by the new 8hp VRV IV HR condenser.

> 7 VRV III Heat recovery systems (20-38hp)> 1 VRV IV Heat recovery system (8hp)> 4.9kW ducted inverter fan coil units> Daikin Intelligent Touch controls

Page 22: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

20 VRV catalogue 2015

A hotel’s reputation depends on how welcome and comfortable

guests feel during their stay – and Daikin UK has a complete solution

for hotels to help create the perfect ambience. Yet at the same time,

hotel operators must maintain complete control of their operating

costs and energy consumption.

Hospitality with economy

Daikin’s cost-effective solutions can offer total control of hotel air conditioning, ventilation, heating and hot water, with stylish yet silent, draft-free indoor units that promise a good night’s sleep. And because VRV is a modular solution, upgrade and renovation projects can be phased to minimise interruption.

Integrated heat recovery

Integrated solutions offer zone by zone control of hospitality areas and guest bedrooms:

> Recovering heat from areas requiring cooling and re-using for low cost heating and hot water

> Creating the perfect environment for guests by simultaneously heating spaces while cooling others

> Maximising hospitality space with outdoor heat pump installation, or opting for indoor installation in city centres, to minimise external space and noise.

Heating water with renewable energy

Renewable energy can be used to produce low-cost hot water for bathrooms, under floor heating and radiators, thanks to VRV heat recovery solutions, which reclaim waste heat from areas requiring cooling to heat hot water up to 80°C.

Smart energy management

Daikin VRV systems can be controlled centrally, in tandem with other building services such as lighting and fire alarm systems, for optimum comfort, efficiency and safety:

> Centralised management available for VRV systems with up to 2,560 indoor units

> Controls offer intuitive navigation, graphical interface and extensive reporting

> Energy consumption can be set per indoor unit > Controls can be integrated with other systems

e.g. lighting, fire alarms etc. > Online monitoring and control is available for

multiple buildings.

Intelligent hotel room controller

Hotel owners need full control of energy use. A Daikin intelligent controller can adjust the system setpoint when bedrooms are vacant or windows are opened, thus preventing unnecessary energy consumption to maintain absolute control over the hotel’s running costs and environmental impact. Daikin’s intelligent room controller:

> Connects to all types of controllers, including easy to use touch screens

> Integrates easily with hotel management software.

Page 23: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

21VRV catalogue 2015

App

licat

ions

Case studyBloomsbury Hotel, London

In a nine-month phased project, the Grade II listed Bloomsbury Hotel replaced an ageing air conditioning system to beat the ban on R22 refrigerant and achieve significant energy savings.

As part of ongoing upgrade programme, the hotel’s owners, The Doyle Collection, wanted to cut energy usage and CO

2

emissions. They opted for a Daikin VRV-Q system, which is 40% more efficient in heating and 25% better in cooling than R22 systems.

VRV-Q has the added benefit of allowing the re-use of existing pipework and some indoor units – reducing replacement costs and speeding up installation. At the Bloomsbury, the installation cost savings were about 50%. The phased replacement also minimised the impact on occupancy rates and therefore the effect on revenue.

In its first year of operation, the VRV-Q system helped reduced the Bloomsbury Hotel’s energy usage by 15,000kWh – independently assessed as a 23.5% year-on-year saving.

“The Daikin system is more efficient and certainly quieter than the old one. Our energy bills are between 23% and 26% lower than before the system was changed.”Michael Neve, General Manager, Bloomsbury Hotel

> 56 VRV-Q outdoor units> 209 indoor units

Case studyChester Hotel, Aberdeen

A £5 million refurbishment programme, which saw the Simpsons Hotel in Aberdeen transform into the five star Chester Hotel, sparked some special creativity in air conditioning design for public areas.

Chris Thoms, Mechanical Design Manager for Hutcheon Services, Aberdeen, was tasked with providing a five star air conditioning solution for the new-look hotel. The system chosen to air-condition the public areas and the conference and wedding facilities was Daikin VRV III Heat Recovery.

“ The client was keen on the Daikin system for its high energy efficiency and the benefits of a VRV heating and cooling system,” he says.

“ It was challenging getting the air conditioning for the main conference room into the project because of the thickness of acoustic insulation above the ceiling. There wasn’t really a ceiling void to house the units.”

Various alternatives were considered, but the chosen solution was to fabricate ‘domes’ matching the circular overhead light fittings selected for the conference room. The domes provided depth to accommodate Daikin slim ducted fan coil units, each with a nominal 7kW of cooling and 8kW of heating.

> Daikin VRV III heat recovery> Slim ducted fan coil units> Ducted inverter fan coil units> VAM heat recovery ventilation unit> iTouch Manager

Page 24: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

22 VRV catalogue 2015

Public buildings are under increasing pressure to lead the way in

sustainability, in order to reduce carbon emissions – and improve

energy efficiency as part of overall strategy to spend public money

more carefully.

The government estate makes up a significant part of the built environment, providing working places for 5.4 million people – about 18% of the workforce. According to the Office of National Statistics, ‘public’ buildings are responsible for about 10 million tonnes of CO

2 annually.

In seeking to meet energy efficiency targets across both public and private sectors, government and its agencies have to demonstrate a willingness to replace outdated and wasteful heating and cooling systems with efficient modern technology.

VRV systems provide ideal solutions for most public buildings, offering operating cost savings, a reduced carbon footprint, high efficiency in all ambient conditions and a working environment that is always comfortable for staff and visitors. VRV is the established leader in air conditioning technology – and the perfect tool to lead the drive for carbon reduction.

Public buildings

lead the way

Page 25: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

23VRV catalogue 2015

App

licat

ions

Case studyPortcullis House, Cardiff

Switching to Daikin VRV IV heat recovery air conditioning as part of a major refurbishment project has given the owners of a 3,600m2 Cardiff office building an additional benefit – a healthy extra 350m2 of space to let to the new tenant, the NHS.

Portcullis House, previously occupied by HMRC, has three storeys of open plan offices and seven storeys of smaller offices and meeting rooms in a taller wing behind.

An old four-pipe air conditioning system, with floor-mounted fan coil units, piping and associated trunking on perimeter walls, has been removed – yielding the 10% increase in lettable space. Heating and cooling for the old system was provided by boilers and chillers – all of which were in a poor state.

Daikin’s brand new VRV IV heat recovery air conditioning was specified for its cutting edge technology and high efficiency. As an added benefit, its refrigerant piping, branch selector boxes and round flow cassettes could all be accommodated within the existing ceiling voids.

Portcullis House has a fairly high degree of solar gain, which means that it often requires simultaneous cooling and heating. The VRV IV heat recovery facility means rejected thermal energy from the ‘hot’ side can be used efficiently to warm the colder parts of the building.

> 3 VRV IV heat recovery condensing units (22h and 26hp)> 38 Roundflow Cassettes (1.8kW to 7.2kW)> 21 Wall-mounted fan coil units (1.2kW to 2.9kW)

Case studyPalace of Westminster, London

During a refurbishment project at the Houses of Parliament, Daikin’s innovative VRV-Q plug-in system was selected to replace outdated air conditioning systems using now banned R22 refrigerant.

Like many other buildings with R22 systems, the iconic London landmark had to make the change because of the phase-out of the gas. New sources of R22 were banned in 2010 and recycled gas was also banned from 31December 2014 under European environmental legislation.

VRV-Q uses R410A refrigerant, which has zero ozone depletion potential and reduces associated CO

2 emissions. VRV-Q also

improves energy efficiency and is able to reduce energy consumption by up to 40%.

VRV-Q offers a technically secure and cost-effective option to a full system upgrade. It can reduce the cost of an R22 upgrade by up to 50% because VRV-Q outdoor units are designed to work with existing R22 piping – and potentially also controllers and indoor units manufactured after 1996. This means only the outdoor units and heat recovery branch selector boxes have to be changed – saving time and reducing costs.

A fast and effective upgrade is possible because VRV-Q operates at lower pressures to suit existing R22 piping, without compromising efficiency levels. In fact, a VRV-Q 10hp system has a COP of 3.98 and an EER of 4.00 – around 50% more efficient than the equivalent R22 system it replaces.

Page 26: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

24 VRV catalogue 2015

Small footprint combination

> Optimised footprint within heat recovery range

High COP combination

> Top energy efficiency in Daikin heat recovery range

VRV heat recovery, with connection to heating only hydrobox

> Fully integrated system > Free hot water > For either heating or cooling operation

from one system

VRV Heat Recovery> For simultaneous heating and cooling from the same system

> Heat recovered from indoor units is recycled to provide heat for indoor spaces, to water and for fresh air. This maximises efficiency and reduces running costs by delivering high part load efficiencies

> Select a system with a small footprint or increase even further your efficiency by combining higher efficiency condensers to meet the projects requirements

> Provide cooling even with an ambient temperature as low as -20°C

> The widest range of installation options available with the smaller, quieter and lighter range of single and multi BS boxes

VRV IV Heat Recovery – REYQ-T 25

Page 27: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

25VRV catalogue 2015

Hea

t Rec

over

y

Outdoor Units 13 HP Multi 14 HP Single 16 HP Single 16 HP MultiREYQ8T REMQ5T REYQ14T REYQ16T REYQ8T REYQ8T

Capacity Nominal Cooling kW 36.40 40.00 45.00 45.00Nominal Heating kW 33.50 40.00 45.00 45.00

Dimensions Height x Width x Depth mm 1685 x 930 x 765 1685 x 930 x 765 1685 x 1240 x 765 1685 x 1240 x 765 1685 x 930 x 765 1685 x 930 x 765Weight kg 198 198 319 319 198 198Fan Air Flow Rate m3/sec 2.70 2.70 3.72 4.33 2.70 2.70Electrical Details Power Supply Phase 3ph / 50 Hz / 380~415V

Running Current amps 8.9 5.3 17.4 21.1 8.9Starting Current amps 4Fuse Rating amps 20 20 32 40 20 20

Refrigerant Circuit Refrigerant Type R410ARefrigerant Charge kg data book data book data book data bookAdditional Charge kg data book

Sound Pressure dBA 58 58 61 64 58 58Sound Power dBA 78 78 81 86 78 78Piping Limits Maximum Total Length m 1000

Maximum Actual Length m 165Piping Connections - Systems

Liquid inches 1 1/8 1 1/8 1 1/8 1 1/8Gas inches 1/2 1/2 1/2 1/2Discharge inches 3/4 7/8 7/8 7/8

Capacity Index Limit 162.5 ~ 422.5 175 ~ 455 200 ~ 520 200 ~ 520Maximum Number of Connected Indoor Units 64 64 64 64

REYQ-T

VRV IV Condensing Units – Heat Recovery

Outdoor Units 8 HP Single 10 HP Single 10 HP Multi 12 HP SingleREYQ8T REYQ10T REMQ5T REMQ5T REYQ12T

Capacity Nominal Cooling kW 22.40 28.00 28.00 33.50Nominal Heating kW 22.40 28.00 28.00 33.50

Dimensions Height x Width x Depth mm 1685 x 930 x 765 1685 x 930 x 765 1685 x 930 x 765 1685 x 930 x 765 1685 x 930 x 765Weight kg 198 205 198 198 205Fan Air Flow Rate m3/sec 2.70 2.92 2.70 2.70 3.08Electrical Details Power Supply Phase 3ph / 50 Hz / 380~415V

Running Current amps 8.9 11.8 5.3 15.3Starting Current amps 4Fuse Rating amps 20 25 20 20 25

Refrigerant Circuit Refrigerant Type R410ARefrigerant Charge kg data book data book data book data bookAdditional Charge kg data book

Sound Pressure dBA 58 58 58 58 61Sound Power dBA 78 79 78 78 81Piping Limits Maximum Total Length m 1000

Maximum Actual Length m 165Piping Connections - Systems

Liquid inches 3/4 7/8 7/8 1 1/8Gas inches 3/8 3/8 3/8 1/2Discharge inches 5/8 3/4 3/4 3/4

Capacity Index Limit 100 ~ 260 125 ~ 325 125 ~ 325 150 ~ 390Maximum Number of Connected Indoor Units 64 64 64 64

REYQ-T (8 to 12 HP)

REYQ-T (13 to 16 HP)

Page 28: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

26 VRV catalogue 2015

REYQ-T

VRV IV Condensing Units – Heat Recovery

REYQ-T (18 to 20 HP)

REYQ-T (22 to 28 HP)

Outdoor Units 18 HP Single 18 HP Multi 20 HP Single 20 HP Multi REYQ18T REYQ8T REYQ10T REYQ20T REYQ10T REYQ10T

Capacity Nominal Cooling kW 50.00 51.00 56.00 56.00Nominal Heating kW 51.00 51.00 56.00 56.00

Dimensions Height x Width x Depth mm 1685 x 1240 x 765 1685 x 930 x 765 1685 x 930 x 765 1685 x 1240 x 765 1685 x 930 x 765 1685 x 930 x 765Weight kg 329 198 205 329 205 205Fan Air Flow Rate m3/sec 4.18 2.70 2.92 4.35 2.92 2.92Electrical Details Power Supply Phase 3ph / 50 Hz / 380~415V

Running Current amps 24.6 8.9 11.8 31.1 11.8Starting Current amps 4Fuse Rating amps 40 20 25 50 25 25

Refrigerant Circuit Refrigerant Type R410ARefrigerant Charge kg data book data book data book data book data bookAdditional Charge kg data book

Sound Pressure dBA 65 58 58 66 58 58Sound Power dBA 86 78 79 88 79 79Piping Limits Maximum Total Length m 1000

Maximum Actual Length m 165Piping Connections - Systems

Liquid inches 1 1/8 3/4 1 1/8 1 1/8Gas inches 5/8 3/8 5/8 5/8Discharge inches 7/8 5/8 1 1/8 1 1/8

Capacity Index Limit 225 ~ 450 100 ~ 260 250 ~ 650 250 ~ 650Maximum Number of Connected Indoor Units 64 64 64 64

Outdoor Units 22 HP Multi 24 HP Multi 26 HP Multi 28 HP Multi REYQ10T REYQ12T REYQ8T REYQ16T REYQ12T REYQ14T REYQ12T REYQ16T

Capacity Nominal Cooling kW 61.50 67.40 73.50 78.50Nominal Heating kW 61.50 67.40 73.50 78.50

Dimensions Height x Width x Depth mm 1685 x 930 x 765

1685 x 930 x 765

1685 x 930 x 765

1685 x 1240 x 765

1685 x 930 x 765

1685 x 1240 x 765

1685 x 930 x 765

1685 x 1240 x 765

Weight kg 205 205 210 305 205 319 205 319Air Flow Rate m3/sec 2.92 3.08 2.70 4.33 3.08 3.72 3.08 4.33Electrical Details Power Supply Phase 3ph / 50 Hz / 380~415V

Running Current amps 11.8 15.3 8.9 21.1 15.3 17.4 15.3 21.1Starting Current amps 4Fuse Rating amps 25 25 20 40 25 32 25 40

Refrigerant Circuit Refrigerant Type R410ARefrigerant Charge kg data book data book data book data bookAdditional Charge kg data book

Sound Pressure dBA 58 61 58 64 61 61 61 64Sound Power dBA 79 81 78 86 81 81 81 86Piping Limits Maximum Total Length m 1000

Maximum Actual Length m 165Piping Connections - Systems

Liquid inches 1 1/8 1 3/8 1 3/8 1 3/8Gas inches 5/8 3/4 3/4 3/4Discharge inches 1 1/8 1 1/8 1 1/8 1 1/8

Capacity Index Limit 275 ~ 715 300 ~ 780 325 ~ 845 350 ~ 910Maximum Number of Connected Indoor Units 64 64 64 64

Page 29: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

27VRV catalogue 2015

Hea

t Rec

over

y

Outdoor Units 38 HP Multi 40 HP Multi 42 HP Multi REYQ8T REYQ12T REYQ18T REYQ10T REYQ12T REYQ18T REYQ10T REYQ16T REYQ16T

Capacity Nominal Cooling kW 106.40 111.50 118.00Nominal Heating kW 106.40 111.50 118.00

Dimensions Height x Width x Depth mm 1685 x 930 x 765

1685 x 930 x 765

1685 x 1240 x

765

1685 x 930 x 765

1685 x 930 x 765

1685 x 1240 x

765

1685 x 930 x 765

1685 x 1240 x

765

1685 x 1240 x

765Weight kg 210 218 337 205 205 329 205 319 319Fan Air Flow Rate m3/sec 2.70 3.08 4.18 2.92 3.08 4.18 2.92 4.33 4.33Electrical Details Power Supply Phase 3ph / 50 Hz / 380~415V

Running Current amps 8.9 15.3 24.6 11.8 15.3 24.6 11.8 21.1 21.1Starting Current amps 4Fuse Rating amps 20 25 40 25 25 40 25 40 40

Refrigerant Circuit Refrigerant Type R410ARefrigerant Charge kg data book data book data bookAdditional Charge kg data book data book data book

Sound Pressure dBA 58 61 65 58 61 65 58 64 64Sound Power dBA 78 81 86 79 81 86 79 86 86Piping Limits Maximum Total Length m 1000 1000 1000

Maximum Actual Length m 165 165 165Piping Connections - Systems

Liquid inches 1 5/8 1 5/8 1 5/8Gas inches 3/4 3/4 3/4Discharge inches 1 3/8 1 3/8 1 3/8

Capacity Index Limit 475 ~ 1235 500 ~ 1300 525 ~ 1365Maximum Number of Connected Indoor Units 64 64 64

REYQ-T

VRV IV Condensing Units – Heat Recovery

REYQ-T (30 to 36 HP)

REYQ-T (38 to 42 HP)

Outdoor Units 30 HP Multi 32 HP Multi 34 HP Multi 36 HP Multi REYQ12T REYQ18T REYQ16T REYQ16T REYQ16T REYQ18T REYQ16T REYQ20T

Capacity Nominal Cooling kW 83.50 90.00 95.00 101.00Nominal Heating kW 83.50 90.00 95.00 101.00

Dimensions Height x Width x Depth mm 1685 x 930 x 765

1685 x 1240 x 765

1685 x 1240 x 765

1685 x 1240 x 765

1685 x 1240 x 765

1685 x 1240 x 765

1685 x 1240 x 765

1685 x 1240 x 765

Weight kg 205 329 319 319 319 329 319 329Fan Air Flow Rate m3/sec 3.08 4.18 4.33 4.33 4.33 4.18 4.33 4.35Electrical Details Power Supply Phase 3ph / 50 Hz / 380~415V

Running Current amps 15.3 24.6 21.1 21.1 24.6 21.1 31.1Starting Current amps 4Fuse Rating amps 25 40 40 40 40 40 40 50

Refrigerant Circuit Refrigerant Type R410ARefrigerant Charge kg data book data book data book data bookAdditional Charge kg data book

Sound Pressure dBA 61 65 64 64 64 65 64 66Sound Power dBA 81 86 86 86 86 86 86 88Piping Limits Maximum Total Length m 1000

Maximum Actual Length m 165Piping Connections - Systems

Liquid inches 1 3/8 1 3/8 1 3/8 1 5/8Gas inches 3/4 3/4 3/4 3/4Discharge inches 1 1/8 1 1/8 1 1/8 1 1/8

Capacity Index Limit 375 ~ 975 400 ~ 1040 425 ~ 1105 450 ~ 1170Maximum Number of Connected Indoor Units 64 64 64 64

Page 30: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

28 VRV catalogue 2015

Outdoor Units 44 HP Multi 46 HP Multi 48 HP Multi REYQ12T REYQ16T REYQ16T REYQ14T REYQ16T REYQ16T REYQ16T REYQ16T REYQ16T

Capacity Nominal Cooling kW 123.50 130.00 135.00Nominal Heating kW 123.50 130.00 135.00

Dimensions Height x Width x Depth mm 1685 x 930 x 765

1685 x 1240 x

765

1685 x 1240 x

765

1685 x 1240 x

765

1685 x 1240 x

765

1685 x 1240 x

765

1685 x 1240 x

765

1685 x 1240 x

765

1685 x 1240 x

765Weight kg 205 319 319 319 319 319 319 319 319Fan Air Flow Rate m3/sec 3.08 4.33 4.33 3.72 4.33 4.33 4.33 4.33 4.33Electrical Details Power Supply Phase 3ph / 50 Hz / 380~415V

Running Current amps 15.3 21.1 21.1 17.4 21.1 21.1 21.1Starting Current amps 4Fuse Rating amps 25 40 40 32 40 40 40 40 40

Refrigerant Circuit Refrigerant Type R410ARefrigerant Charge kg data book data book data bookAdditional Charge kg data book data book data book

Sound Pressure dBA 61 64 64 61 64 64 64 64 64Sound Power dBA 81 86 86 81 86 86 86 86 86Piping Limits Maximum Total Length m 1000 1000 1000

Maximum Actual Length m 165 165 165Piping Connections - Systems

Liquid inches 1 5/8 1 5/8 1 5/8Gas inches 3/4 3/4 3/4Discharge inches 1 3/8 1 3/8 1 3/8

Capacity Index Limit 550 ~ 1430 575 ~ 1495 600 ~ 1560Maximum Number of Connected Indoor Units 64 64 64

Outdoor Units 50 HP Multi 52 HP Multi 54 HP Multi REYQ16T REYQ16T REYQ18T REYQ16T REYQ18T REYQ18T REYQ18T REYQ18T REYQ18T

Capacity Nominal Cooling kW 140.00 145.00 150.00Nominal Heating kW 140.00 145.00 150.00

Dimensions Height x Width x Depth mm 1685 x 1240 x

765

1685 x 1240 x

765

1685 x 1240 x

765

1685 x 1240 x

765

1685 x 1240 x

765

1685 x 1240 x

765

1685 x 1240 x

765

1685 x 1240 x

765

1685 x 1240 x

765Weight kg 319 319 329 319 329 329 329 329 329Fan Air Flow Rate m3/sec 4.33 4.33 4.18 4.33 4.18 4.18 4.18 4.18 4.18Electrical Details Power Supply Phase 3ph / 50 Hz / 380~415V

Running Current amps 21.1 21.1 24.6 21.1 24.6 24.6 24.6Starting Current amps 4Fuse Rating amps 40 40 40 40 40 40 40 40 40

Refrigerant Circuit Refrigerant Type R410ARefrigerant Charge kg data book data book data bookAdditional Charge kg data book data book data book

Sound Pressure dBA 64 64 65 64 65 65 65 65 65Sound Power dBA 86 86 86 86 86 86 86 86 86Piping Limits Maximum Total Length m 1000 1000 1000

Maximum Actual Length m 165 165 165Piping Connections - Systems

Liquid inches 1 5/8 1 5/8 1 5/8Gas inches 3/4 3/4 3/4Discharge inches 1 3/8 1 3/8 1 3/8

Capacity Index Limit 625 ~ 1625 650 ~ 1690 675 ~ 1755Maximum Number of Connected Indoor Units 64 64 64

REYQ-T

VRV IV Condensing Units – Heat Recovery

REYQ-T (44 to 48 HP)

REYQ-T (50 to 54 HP)

Page 31: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

Hea

t Rec

over

y

Page 32: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

30 VRV catalogue 2015

VRV IV Heat Pump> Customise your VRV for the greatest seasonal efficiency and comfort,

with Variable Refrigerant Temperature control

> Continuous comfort: unique continuous heating technology makes VRV IV Heat Pump the best alternative to traditional heating systems

> VRV configurator software offers faster and more accurate commissioning, configuration and customisation

> Possibility to combine VRV with a wide range of stylish indoor units including Daikin Emura and Nexura

VRV IV Heat Pump – RYYQ-T 31

The new standard in heating comfort 32

VRV IV Heat Pump with continuous heating – RYYQ8-54T 34

Heat Pump Mini VRV range see page 46NEW

Page 33: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

31VRV catalogue 2015

Hea

t Pum

p

4

5

3

1

2

VRV configuratorSimplified commissioning and configuration via

PC connection 7-segment LED indicator enables quick

check of basic functions and easy error read-out

1

Gas cooled PCBUnique design for maximum reliability and higher

efficiency of the heat exchanger

2

Full inverter compressor controlFrequency control range which delivers stepless control

of capacity and Variable Refrigerant Temperature Control

3

Heat accumulating elementProvides energy to defrost the outdoor unit while

continuing to provide indoor heating

4

4 side and 3 row heat exchangerThis unique heat exchanger means 50% more

surface area, so the coil does more of the work,

increasing efficiency

5

VRV IV Heat PumpRYYQ-T

The VRV IV Heat Pump inherits all the renowned technological features of the VRV III and adds

a number of revolutionary technologies, setting the new standard in the market once again.

Variable refrigerant temperature

Customise your VRV for the optimum seasonal efficiency and comfort: revolutionary variable refrigerant temperature control (optimised by Daikin for UK conditions for maximum efficiency and comfort) automatically adapts the system to the individual building and climate requirements.

Continuous heating during defrost via heat pump

The new standard in heating comfort: unique continuous heating technology makes VRV IV Heat Pump the best alternative to traditional heating systems.

VRV configurator

Software for simplified commissioning, configuration and customisation.

> Simplified commissioning: graphical interface to configure, commission and upload system settings

> Simplified servicing: additional 7-segment indicator for easy and quick access to basic functions and error read out.

Page 34: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

32 VRV catalogue 2015

> Unique continuous heating technology

> The best alternative to traditional heating systems

The new standard

in heating comfort

VRV IV Heat Pump for continuous comfort, even during defrost

Because the VRV IV Heat Pump continues to provide continuous heating even when in defrost mode, it provides the answer to any perceived disadvantages of specifying a heat pump for monovalent heating.

Heat pumps are known for their high energy efficiency in heating, but they accumulate ice during heating operation and this must be melted periodically using a defrost function that reverses the refrigeration cycle. This causes a temporary temperature drop, which can reduce comfort levels inside the building.

Defrosting can take over 10 minutes (depending on the size of the system) and occurs most frequently between -7 and +7°C when there is most humidity.

How does it work?

VRV IV Heat Pump features a unique heat-accumulating element, based on phase change materials, which provides energy to defrost the outdoor unit while continuing to provide heating, thus maintaining a comfortable indoor climate. The energy needed for defrosting is stored in the element during normal heating operations.

How phase change material works

A phase change material (PCM) will store or release energy when it changes phase from solid to liquid or liquid to solid.

The outdoor unit coil is defrosted …

… with the energy stored in the heat accumulating element …

… while indoors a comfortable temperature is maintained.

Capsule shell

Temperature rises

As PCM solidifies, heat energy is released back into the environment

As PCM absorbs heat energy,

it liquifies

Temperature falls

PCM in liquid state

Capsule shell

PCM in solid state

Continuous heating function is only available on RYYQ-T units.

VRV IV

VRF benchmark

Room temperature

TimeΔT

new

Page 35: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

33VRV catalogue 2015

Hea

t Pum

p

A field trial at a German fashion chain store demonstrated how the innovative features of VRV IV have improved energy efficiency dramatically over previous models.

The results of the trial showed that the new VRV IV system consumed much less energy, particularly when cooling, compared with the VRV III system – in some cases up to 60% less. When heating, savings were an average of 20%.

The Unterhaching trial demonstrates how VRV IV heat pump technology uses a renewable energy source – air – to provide a complete and environmentally sustainable solution for heating, cooling, and ventilation in commercial environments. The trial also shows that businesses can only identify and control energy wastage through careful and intelligent monitoring of climate control systems, a service which Daikin can offer.

40% more efficient

proven in practice

Monthly power consumption4,500

4,000

3,500

3,000

2,500

2,000

1,500

1,000

500

0Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb

2012

2013

Ambient temp (average min/max)30

25

20

15

10

5

0

-5

-10

2012: Average max

2013: Average max

2012: Average min

2013: Average min

Date Range Avg kW/h per month Total kW/h Total cost Yearly £/m2

VRV III March 2012 - Feb 2013 2,796.82 33,561.8 £4,027.42 £10.07

VRV IV March 2013 - Feb 2014 1,501.92 18,023 £2,162.76 £5.41

Saved 46%

Page 36: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

34 VRV catalogue 2015

Outdoor Units RYYQ8T RYYQ10T RYYQ12T RYYQ14T RYYQ16T RYYQ18T RYYQ20TCapacity Nominal Cooling kW 22.40 28.00 33.50 40.00 45.00 50.00 56.00

Nominal Heating kW 25.00 31.50 37.50 45.00 50.00 56.00 63.00EER 4.30 3.84 3.73 3.64 3.46 3.40 3.03ESEER 7.53* 7.2* 6.96* 6.83* 6.5* 6.38* 5.67*COP 4.55 4.27 4.12 4.02 3.91 3.89 3.71Dimensions Height x Width x Depth mm 1685 x 930

x 7651685 x 930

x 7651685 x 930

x 7651685 x 1240

x 7651685 x 1240

x 7651685 x 1240

x 7651685 x 1240

x 765Weight kg 261 268 268 364 364 398 398Air Flow Rate m3/sec 2.70 2.92 3.08 3.72 4.33 4.18 4.35External Static Pressure High Pa 78 78 78 78 78 78 78Electrical Details Power Supply Phase /Hz / V 3ph / 50 Hz / 380~415V

Running Current amps 7.2 11.3 12.7 15.4 18.0 20.8 26.9Starting Current amps databookFuse Rating amps 20 25 32 32 40 40 50

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 5.9 6.0 6.3 10.3 10.4 11.7 11.8Additional Charge kg data book

Sound Pressure dBA 58 58 61 61 64 65 66Sound Power dBA 78 79 81 81 86 86 88Piping Limits Maximum Length m 165 165 165 165 165 165 165

Maximum Vertical Rise m data bookPiping Connections Liquid inches 3/8 3/8 1/2 1/2 1/2 5/8 5/8

Gas inches 3/4 7/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8Capacity Index Limit 100~260 125~325 150~390 175~455 200~520 225~585 250~650Maximum Number of Connected Indoor Units 64 64 64 64 64 64 64

* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).

Outdoor Units RYYQ22T RYYQ24TRYMQ10T RYMQ12T RYMQ8T RYMQ16T

Capacity Nominal Cooling kW 61.50 67.40Nominal Heating kW 69.00 75.00

EER 3.77 3.70ESEER 7.07* 6.81*COP 4.18 4.10Dimensions Height x Width x Depth mm 1685 x 930 x 765 1685 x 930 x 765 1685 x 930 x 765 1685 x 1240 x 765Weight kg 195 195 188 309Air Flow Rate m3/sec 2.92 3.08 2.70 4.33External Static Pressure High Pa 78 78 78 78Electrical Details Power Supply Phase /Hz / V 3ph / 50 Hz / 380~415V

Running Current amps 10.2 12.7 7.2 18.0Starting Current amps databookFuse Rating amps 25 32 20 40

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 6.0 6.3 5.9 10.4Additional Charge kg databook

Sound Pressure dBA 58 61 58 64Sound Power dBA 79 81 78 86Piping Limits Maximum Length m 165 165

Maximum Vertical Rise m databookPiping Connections Liquid inches 5/8 5/8

Gas inches 1 1/8 1 3/8Capacity Index Limit 275~715 300~780Maximum Number of Connected Indoor Units 64 64

* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).

RYYQ-T

VRV IV Heat Pump with Continuous Heating

RYYQ-T (up to 20 HP)

RYYQ-T (22 to 24 HP)

Page 37: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

35VRV catalogue 2015

Hea

t Pum

p

Outdoor Units RYYQ26T RYYQ28T RYYQ30T RYYQ32T RYYQ34TRYMQ12T RYMQ14T RYMQ12T RYMQ16T RYMQ12T RYMQ18T RYMQ16T RYMQ16T RYMQ16T RYMQ18T

Capacity Nominal Cooling kW 73.50 78.50 83.50 90.00 95.00Nominal Heating kW 82.50 87.50 93.50 100.00 106.00

EER 3.68 3.57 3.52 3.46 3.43ESEER 6.89* 6.69* 6.6* 6.5* 6.44*COP 4.06 4.00 3.98 3.91 3.90Dimensions Height mm 1685 1685 1685 1685 1685 1685 1685 1685 1685 1685

Width mm 930 1240 930 1240 930 1240 1240 1240 1240 1240Depth mm 765 765 765 765 765 765 765 765 765 765

Weight kg 195 309 195 309 195 319 309 309 309 319Air Flow Rate m3/sec 3.08 3.72 3.08 4.33 3.08 4.18 4.33 4.33 4.33 4.18External Static Pressure High Pa 78 78 78 78 78 78 78 78 78 78Electrical Details Power Supply Phase /Hz / V 3ph / 50 Hz / 380~415V

Running Current amps 12.7 15.4 12.7 18.0 12.7 20.8 18.0 18.0 18.0 20.8Starting Current amps databookFuse Rating amps 32 32 32 40 32 40 40 40 40 40

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 6.3 10.3 6.3 10.4 6.3 11.7 10.4 10.4 10.4 11.7Additional Charge kg data book

Sound Pressure dBA 61 61 61 64 61 65 64 64 64 65Sound Power dBA 81 81 81 86 81 86 86 86 86 86Piping Limits Maximum Length m 165

Maximum Vertical Rise m data bookPiping Connections Liquid inches 3/4 3/4 3/4 3/4 3/4

Gas inches 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8Capacity Index Limit 325~845 350~910 375~975 400~1040 425~1105Maximum Number of Connected Indoor Units 64 64 64 64 64

* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).

Outdoor Units RYYQ36T RYYQ38T RYYQ40T RYYQ42TRYMQ16T RYMQ20T RYMQ8T RYMQ10T RYMQ20T RYMQ10T RYMQ12T RYMQ18T RYMQ10T RYMQ16T RYMQ16T

Capacity Nominal Cooling kW 101.00 106.00 112.00 118.00Nominal Heating kW 113.00 120.00 125.00 132.00

EER 3.21 3.42 3.61 3.54ESEER 6.02* 6.36* 6.74* 6.65*COP 3.79 4.01 4.05 4.00Dimensions Height mm 1685 1685 1685 1685 1685 1685 1685 1685 1685 1685 1685

Width mm 1240 1240 930 930 1240 930 930 1240 930 1240 1240Depth mm 765 765 765 765 765 765 765 765 765 765 765

Weight kg 309 319 188 195 319 195 195 319 195 309 309Air Flow Rate m3/sec 4.33 4.35 2.70 2.92 4.35 2.92 3.08 4.18 2.92 4.33 4.33External Static Pressure High Pa 78 78 78 78 78 78 78 78 78 78 78Electrical Details Power Supply Phase /Hz / V 3ph / 50 Hz / 380~415V

Running Current amps 18.0 26.9 7.2 10.2 26.9 10.2 12.7 20.8 10.2 18.0 18.0Starting Current amps databook databook databook databookFuse Rating amps 40 50 20 25 50 25 32 40 25 40 40

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 10.4 11.8 5.9 6.0 11.8 6.0 6.3 11.7 6.0 10.4 10.4Additional Charge kg data book

Sound Pressure dBA 64 66 58 58 66 58 61 65 58 64 64Sound Power dBA 86 88 78 79 88 79 81 86 79 86 86Piping Limits Maximum Length m 165

Maximum Vertical Rise m data bookPiping Connections Liquid inches 3/4 3/4 3/4 3/4

Gas inches 1 5/8 1 5/8 1 5/8 1 5/8Capacity Index Limit 450~1170 475~1235 500~1300 525~1365Maximum Number of Connected Indoor Units 64 64 64 64

* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).

RYYQ-T

VRV IV Heat Pump with Continuous Heating

RYYQ-T (26 to 34 HP)

RYYQ-T (36 to 42 HP)

Page 38: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

36 VRV catalogue 2015

Outdoor Units RYYQ44T RYYQ46T RYYQ48TRYMQ12T RYMQ16T RYMQ16T RYMQ14T RYMQ16T RYMQ16T RYMQ16T RYMQ16T RYMQ16T

Capacity Nominal Cooling kW 124.00 130.00 135.00Nominal Heating kW 138.00 145.00 150.00

EER 3.54 3.51 3.46ESEER 6.62* 6.6* 6.5*COP 3.98 3.94 3.91Dimensions Height mm 1685 1685 1685 1685 1685 1685 1685 1685 1685

Width mm 930 1240 1240 1240 1240 1240 1240 1240 1240Depth mm 765 765 765 765 765 765 765 765 765

Weight kg 195 309 309 309 309 309 309 309 309Air Flow Rate m3/sec 3.08 4.33 4.33 3.72 4.33 4.33 4.33 4.33 4.33External Static Pressure High Pa 78 78 78 78 78 78 78 78 78Electrical Details Power Supply Phase /Hz / V 3ph / 50 Hz / 380~415V

Running Current amps 12.7 18.0 18.0 15.4 18.0 18.0 18.0 18.0 18.0Starting Current amps databook databook databookFuse Rating amps 32 40 40 32 40 40 40 40 40

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 6.3 10.4 10.4 10.3 10.4 10.4 10.4 10.4 10.4Additional Charge kg data book

Sound Pressure dBA 61 64 64 61 64 64 64 64 64Sound Power dBA 81 86 86 81 86 86 86 86 86Piping Limits Maximum Length m 165

Maximum Vertical Rise m data bookPiping Connections Liquid inches 3/4 3/4 3/4

Gas inches 1 5/8 1 5/8 1 5/8Capacity Index Limit 550~1430 575~1495 600~1560Maximum Number of Connected Indoor Units 64 64 64

* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).

Outdoor Units RYYQ50T RYYQ52T RYYQ54TRYMQ16T RYMQ16T RYMQ18T RYMQ16T RYMQ18T RYMQ18T RYMQ18T RYMQ18T RYMQ18T

Capacity Nominal Cooling kW 140.00 145.00 150.00Nominal Heating kW 156.00 162.00 168.00

EER 3.44 3.42 3.40ESEER 6.46* 6.42* 6.38*COP 3.90 3.89 3.89Dimensions Height mm 1685 1685 1685 1685 1685 1685 1685 1685 1685

Width mm 1240 1240 1240 1240 1240 1240 1240 1240 1240Depth mm 765 765 765 765 765 765 765 765 765

Weight kg 309 309 319 309 319 319 319 319 319Air Flow Rate m3/sec 4.33 4.33 4.18 4.33 4.18 4.18 4.18 4.18 4.18External Static Pressure High Pa 78 78 78 78 78 78 78 78 78Electrical Details Power Supply Phase 3ph / 50 Hz / 380~415V

Running Current amps 18.0 18.0 20.8 18.0 20.8 20.8 20.8 20.8 20.8Starting Current amps databook databook databookFuse Rating amps 40 40 40 40 40 40 40 40 40

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 10.4 10.4 11.7 10.4 11.7 11.7 11.7 11.7 11.7Additional Charge kg data book

Sound Pressure dBA 64 64 65 64 65 65 65 65 65Sound Power dBA 86 86 86 86 86 86 86 86 86Piping Limits Maximum Length m 165

Maximum Vertical Rise m data bookPiping Connections Liquid inches 3/4 3/4 3/4

Gas inches 1 5/8 1 5/8 1 5/8Capacity Index Limit 625~1625 650~1690 675~1755Maximum Number of Connected Indoor Units 64 64 64

* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).

RYYQ-T

VRV IV Heat Pump with Continuous Heating

RYYQ-T (44 to 48 HP)

RYYQ-T (50 to 54 HP)

Page 39: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

Hea

t Pum

p

Page 40: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

38 VRV catalogue 2015

The Daikin low-cost upgrade solution

4 Reuse drain pipes

Durable PVC pipes can be easily reused. Only flow tests are required.

4 Reuse refrigerant pipes

Pipes used for R-22 will also work with VRV-Q, thanks to lower operating pressures of the system.

4 Reuse refrigerant branch pipes

There are no restrictions when upgrading from a Daikin VRV system. Other VRF systems require branch pipes to withstand pressure up to 3.3 MPa.

! Replace indoor units and BS boxes

Contact your local dealer to check compatibility in case you need to keep the indoor units.

4 Reuse remote control wiring

Reuse wiring when upgrading from a Daikin VRV system. In other cases, this will depend on the cable type.

4 Reuse indoor-outdoor wiring

Restrictions: see remote control wiring.

! Replace outdoor units

Replacement VRVR22 is a hydrochlorofluorocarbon (HCFC) which was commonly used in air conditioning

systems. However, both new and recycled sources of R22 are now banned.

Many systems today are still running on R22. But as R22 is no longer available, now’s

the time to replace R22 systems. The good news is that Daikin’s VRV-Q solution delivers

significantly higher energy efficiencies, with the potential of saving up to 50%, compared

with installing a completely new system.

Benefits for your customers 39

VRV-Q how it benefits you 40

Key guidelines for a quality replacement 41

Replacement VRV heat pump – RXYQQ-T 42

Replacement VRV heat recovery – RQCEQ-P3 44

Page 41: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

39VRV catalogue 2015

Repl

acem

ent

Always operationalAvoid loss of business

Replacing now prevents unplanned, lengthy disruption of air conditioning systems. It also avoids loss of business for shops, complaints from guests in hotels, lower working efficiency and loss of tenants in offices.

Quick and easy installation

No interruption of daily business while replacing the system thanks to phased-in, fast installation.

A future-proof, high-quality solution Customers can replace systems cost effectively from other manufacturers with highly-efficient and flexible Daikin VRV technology, featuring higher quality indoor units that deliver enhanced comfort and superior performance.

A cost saving decision

Reduce costs

System upgrades cost less, because only the outdoor and indoor units need to be replaced. This is also the easiest and fastest way to comply with regulations for buildings.

Environment protection

Improved efficiency saves energy and lowers CO₂ emissions as well as reducing your energy costs.

Reduced energy consumption

Comparison of 10HP systems:

Cooling mode

Heating mode

R-410A (RXYQQ-T)R-407C (RSXYP-L7)R-22 (RSXY-KA7)

EER / COP 8HP 10HP

RXYQQ-T (R-410A) 4.30 / 4.54 3.84 / 4.45

RSXYP-L7 (R-407C) 3.10 / 3.14 3.10 / 3.10

RSXY-KA7 (R-22) 2.37 / 2.95 2.37 / 3.00

These benefits will convince

your customer

Lower long-term costsEU Directives prohibit system repairs with R-22 after 31 December 2014. Delaying the

required R-22 replacement until an unplanned system breakdown is a losing game.

Replacement day will come. Installing a technically advanced system lowers energy

consumption and maintenance costs from day one.

Page 42: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

40 VRV catalogue 2015

6 Automatic refrigerant charging, cleaning and testing

Optimise your businessTackle more projects in less time

Due to faster installation. VRV-Q is more economical than replacing the full system with new piping.

Lower installation costs

Offer customers the most cost-effective solution and improve your competitive edge.

Easy as one-two-three

A simple solution: Daikin VRV-Q enables you to handle more projects for more customers in less time and offer them the best price! Everybody wins.

Compare installation stepsConventional solution

1 Recover refrigerant

2 Remove units

3 Remove refrigerant pipes

4 Install new piping & wiring

5 Install new units

6 Leak test

7 Vacuum drying

8 Refrigerant charging

9 Collect contamination

10 Test operation

1 Recover refrigerant

2 Remove units

Re-use existing piping and wiring

3 Install new units

4 Leak test

5 Vacuum drying

VRV-Q

One touch convenience:> Measure and charge

refrigerant> Automatic pipe

cleaning> Test operation

Automatic pipe cleaningThere is no need to clean inside piping as this is handled automatically by the VRV-Q unit. Finally the test operation is performed automatically to save time.

Automatic refrigerant chargeThe unique automatic refrigerant charge eliminates the need to calculate refrigerant volume and ensures that the system will operate perfectly. Not knowing the exact piping lengths because of changes or mistakes in case you didn’t do the original installation or replacing a competitor installation no longer poses a problem.

Up to 45% shorter installation time

VRV-Q

how it benefits you

Page 43: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

41VRV catalogue 2015

Repl

acem

ent

Refrigerant branch pipesRefrigerant branch pipes, including those from other manufacturers, Y-refnets, T-refnets and headers, can be reused under the following conditions:

✓ Pipes are corrosion-free✓ Pipes are insulated✓ Pipes can withstand a pressure up to 3.3 MPa ✓ There are no special components that implement

decompression (e.g. oil trap)✓ Installed copper pipework is in suitable condition

(piping thickness will generally meet specifications, since the unique Daikin VRV solution operates at lower pressure levels)

Refrigerant oilRefrigerant piping can be reused if one of the following oils was used: Barrel Freeze, Ethereal, Ester, Ferreol, HAB, MS, Suniso.

Maximum piping lengths and level distancesVRV-Q can be installed for piping systems with a total length up to 300m. See the illustration below for further requirements.

Total piping length: 300m

Longest piping length (1–7) actual / equivalent: 120m / 150m

Maximum difference between

shortest (A) and longest (B) branch: 40m

5m Level difference between

outdoor units

50m Level difference

between indoor and

outdoor units (40m if

outdoor unit is installed

below indoor unit)

10m

Piping length between outdoor units

A (4–5)

B (6–7)

15m Level difference

between indoor

units

5

3

4

6

7

1

2

Key guidelines for a quality replacement with VRV-Q

Page 44: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

42 VRV catalogue 2015

Outdoor Units RXYQQ22T RXYQQ24T RXYQQ26T RXYQQ28TRXYQQ10T RXYQQ12T RXYQQ8T RXYQQ16T RXYQQ12T RXYQQ14T RXYQQ12T RXYQQ16T

Capacity Nominal Cooling kW 61.50 67.40 73.50 78.50Nominal Heating kW 69.00 75.00 82.50 87.50

EER 3.77 3.70 3.68 3.57ESEER 7.07* 6.81* 6.89* 6.69*COP 4.18 4.10 4.06 4.00Dimensions Height mm 1685 1685 1685 1685 1685 1685 1685 1685

Width mm 930 930 930 1240 930 1240 930 1240Depth mm 765 765 765 765 765 765 765 765

Weight kg 194 194 187 305 194 306 194 305Air Flow Rate m3/sec 2.92 3.08 2.10 3.88 3.08 3.72 3.08 3.88External Static Pressure High Pa 78 78 78 78Electrical Details Power Supply Phase /Hz / V 3ph / 50 / 400

Running Current amps 22.9 25.2 28.1 30.7Starting Current amps 88Fuse Rating amps 25 32 20 40 32 32 32 40

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 6.0 6.3 5.2 10.4 6.3 10.3 6.3 10.4Additional Charge kg data book

Sound Pressure dBA 58 61 58 64 61 61 61 64Sound Power dBA 79 81 78 86 81 81 81 86Piping Limits Maximum Length m 120

Maximum Vertical Rise m 50Piping Connections Liquid inches 5/8 5/8 3/4 3/4

Gas inches 1 1/8 1 3/8 1 3/8 1 3/8Capacity Index Limit 275~715 300~780 325~845 350~910Maximum Number of Connected Indoor Units 64 64 64 64

*The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrifgerant temperature control operation).

Outdoor Units RXYQQ8T RXYQQ10T RXYQQ12T RXYQQ14T RXYQQ16T RXYQQ18T RXYQQ20TCapacity Nominal Cooling kW 22.40 28.00 33.50 40.00 45.00 50.00 56.00

Nominal Heating kW 25.00 31.50 37.50 45.00 50.00 56.00 63.00EER 4.30 3.84 3.73 3.64 3.46 3.40 3.03ESEER 7.53* 7.2* 6.96* 6.83* 6.5* 6.38* 5.67*COP 4.54 4.27 4.12 4.02 3.91 3.89 3.71Dimensions Height mm 1685 1685 1685 1685 1685 1685 1685

Width mm 930 930 930 1240 1240 1240 1240Depth mm 765 765 765 765 765 765 765

Weight kg 187 194 194 306 305 314 314Air Flow Rate m3/sec 2.10 2.92 3.08 3.72 3.88 4.18 4.35External Static Pressure High Pa 78 78 78 78 78 78 78Electrical Details Power Supply Phase /Hz / V 3ph / 50 / 400

Running Current amps 7.2 10.2 12.7 15.4 18.0 20.8 26.9Starting Current amps 4Fuse Rating amps 20 25 32 32 40 40 50

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 5.2 6.0 6.3 10.3 10.4 11.7 11.8Additional Charge kg data book

Sound Pressure dBA 58 58 61 61 64 65 66Sound Power dBA 78 79 81 81 86 86 88Piping Limits Maximum Length m 120 120 120 120 120 120 120

Maximum Vertical Rise m 50Piping Connections Liquid inches 3/8 3/8 1/2 1/2 1/2 5/8 5/8

Gas inches 3/4 7/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8Capacity Index Limit 100~260 125~325 150~390 175~455 200~520 225~585 250~650Maximum Number of Connected Indoor Units 64 64 64 64 64 64 64

*The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrifgerant temperature control operation).

RXYQQ-T

VRV IV-Q Condensing Units – Heat Pump

RXYQQ-T (up to 20 HP)

RXYQQ-T (22 to 28 HP)

Page 45: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

43VRV catalogue 2015

Repl

acem

ent

Outdoor Units RXYQQ30T RXYQQ32T RXYQQ34T RXYQQ36TRXYQQ12T RXYQQ18T RXYQQ16T RXYQQ16T RXYQQ16T RXYQQ18T RXYQQ16T RXYQQ20T

Capacity Nominal Cooling kW 83.50 90.00 95.00 101.00Nominal Heating kW 93.50 100.00 106.00 113.00

EER 3.52 3.46 3.43 3.21ESEER 6.6* 6.5* 6.44* 6.02*COP 3.98 3.91 3.90 3.79Dimensions Height mm 1685 1685 1685 1685 1685 1685 1685 1685

Width mm 930 1240 1240 1240 1240 1240 1240 1240Depth mm 765 765 765 765 765 765 765 765

Weight kg 194 314 305 305 305 314 305 314Air Flow Rate m3/sec 3.08 4.18 3.88 3.88 3.88 4.18 3.88 4.35External Static Pressure High Pa 78 78 78 78Electrical Details Power Supply Phase /Hz / V 3ph / 50 / 400

Running Current amps 33.5 36.0 38.8 44.9Starting Current amps 108Fuse Rating amps 32 40 40 40 40 40 40 50

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 6.3 11.7 10.4 10.4 10.4 11.7 10.4 11.8Additional Charge kg data book

Sound Pressure dBA 61 65 64 64 64 65 64 66Sound Power dBA 81 86 86 86 86 86 86 88Piping Limits Maximum Length m 120

Maximum Vertical Rise m 50Piping Connections Liquid inches 3/4 3/4 3/4 3/4

Gas inches 1 3/8 1 3/8 1 3/8 1 5/8Capacity Index Limit 375~975 400~1040 425~1105 450~1170Maximum Number of Connected Indoor Units 64 64 64 64

*The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrifgerant temperature control operation).

Outdoor Units RXYQQ38T RXYQQ40T RXYQQ42TRXYQQ8T RXYQQ10T RXYQQ20T RXYQQ10T RXYQQ12T RXYQQ18T RXYQQ10T RXYQQ16T RXYQQ16T

Capacity Nominal Cooling kW 106.00 112.00 118.00Nominal Heating kW 120.00 125.00 132.00

EER 3.42 3.61 3.54ESEER 6.36* 6.74* 6.65*COP 4.01 4.05 4.00Dimensions Height mm 1685 1685 1685 1685 1685 1685 1685 1685 1685

Width mm 930 930 1240 930 930 1240 930 1240 1240Depth mm 765 765 765 765 765 765 765 765 765

Weight kg 187 194 314 194 194 314 194 305 305Air Flow Rate m3/sec 2.10 2.92 4.35 2.92 3.08 4.18 2.92 3.88 3.88External Static Pressure High Pa 78 78 78 78 78 78 78 78 78Electrical Details Power Supply Phase /Hz / V 3ph / 50 / 400

Running Current amps 44.3 43.7 46.2Starting Current amps 111 111 122Fuse Rating amps 20 25 50 25 32 40 25 40 40

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 5.2 6.0 11.8 6.0 6.3 11.7 6.0 10.4 10.4Additional Charge kg data book

Sound Pressure dBA 58 58 66 58 61 65 58 64 64Sound Power dBA 78 79 88 79 81 86 79 86 86Piping Limits Maximum Length m 120

Maximum Vertical Rise m 50Piping Connections Liquid inches 3/4 3/4 3/4

Gas inches 1 5/8 1 5/8 1 5/8Capacity Index Limit 475~1235 500~1300 525~1365Maximum Number of Connected Indoor Units 64 64 64

*The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrifgerant temperature control operation).

RXYQQ-T

VRV IV-Q Condensing Units – Heat Pump

RXYQQ-T (30 to 36 HP)

RXYQQ-T (38 to 42 HP)

Page 46: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

44 VRV catalogue 2015

Outdoor Units RQCEQ280P3 RQCEQ360P3 RQCEQ460P3RQEQ140P3 RQEQ140P3 RQEQ180P3 RQEQ180P3 RQEQ140P3 RQEQ140P3 RQEQ180P3

Capacity Nominal Cooling kW 28.00 36.00 45.00Nominal Heating kW 32.00 40.00 52.00

Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680Width mm 635 635 635 635 635 635 635Depth mm 765 765 765 765 765 765 765

Weight kg 175 175 175 175 175 175 175Air Flow Rate m3/sec 1.58 1.58 1.58 1.58 1.58 1.58 1.58External Static Pressure High Pa 78 78 78Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 5.5+5.5 8.0+8.0 5.5+5.5+8.0Starting Current amps 4 4 4Fuse Rating amps 15 15 20 20 15 15 20

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 10.3 10.3 10.6 10.6 10.3 10.3 10.6Additional Charge kg data book

Sound Pressure dBA 54 54 58 58 54 54 58Piping Limits Maximum Length m 120 120 120

Maximum Vertical Rise m 50Piping Connections Liquid inches 3/8 1/2 1/2

Gas inches 7/8 1 1 1/8Capacity Index Limit 125~325 162.5~422.5 200~520Maximum Number of Connected Indoor Units 16 20 26

Outdoor Units RQCEQ500P3 RQCEQ540P3 RQCEQ636P3RQEQ140P3 RQEQ180P3 RQEQ180P3 RQEQ180P3 RQEQ180P3 RQEQ180P3 RQEQ212P3 RQEQ212P3 RQEQ212P3

Capacity Nominal Cooling kW 50.00 54.00 63.60Nominal Heating kW 56.00 60.00 67.20

Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680 1680Width mm 635 635 635 635 635 635 635 635 635Depth mm 765 765 765 765 765 765 765 765 765

Weight kg 175 175 175 175 175 175 179 179 179Air Flow Rate m3/sec 1.58 1.58 1.58 1.58 1.58 1.58 1.83 1.83 1.83Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 5.5+8.0+8.0 8.0+8.0+8.0 11.5+11.5+11.5Starting Current amps 4 4 4Fuse Rating amps 15 20 20 20 20 20 20 20 20

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 10 11 11 11 11 11 11 11 11Additional Charge kg data book

Sound Pressure dBA 54 58 58 58 58 58 60 60 60Piping Limits Maximum Length m 120

Maximum Vertical Rise m 50Piping Connections Liquid inches 5/8 5/8 5/8

Gas inches 1 1/8 1 1/8 1 1/8Discharge inches 7/8 7/8 1Oil Equalising inches - - -

Capacity Index Limit 225~585 250~650 275~715Maximum Number of Connected Indoor Units 29 33 36

RQCEQ-P3

VRV III-Q Condensing Units – Heat Recovery

RQCEQ-P3 (28.0 to 45.0 kW)

RQCEQ-P3 (50.0 to 63.6 kW)

Page 47: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

45VRV catalogue 2015

Repl

acem

ent

Outdoor Units RQCEQ712P3 RQCEQ744P3RQEQ140P3 RQEQ180P3 RQEQ180P3 RQEQ212P3 RQEQ140P3 RQEQ180P3 RQEQ212P3 RQEQ212P3

Capacity Nominal Cooling kW 71.20 74.40Nominal Heating kW 78.40 80.80

Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680Width mm 635 635 635 635 635 635 635 635Depth mm 765 765 765 765 765 765 765 765

Weight kg 175 175 175 179 175 175 179 179Air Flow Rate m3/sec 1.58 1.58 1.58 1.83 1.58 1.58 1.83 1.83Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 5.5+8.0+8.0+11.5 5.5+8.0+11.5+11.5Starting Current amps 4 4Fuse Rating amps 15 20 20 20 15 20 20 20

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 10.3 10.6 10.6 11.2 10.3 10.6 11.2 11.2Additional Charge kg data book

Sound Pressure dBA 54 58 58 60 54 58 60 60Piping Limits Maximum Length m 120

Maximum Vertical Rise m 50Piping Connections Liquid inches 5/8 3/4

Gas inches 1 1/8 1 3/8Discharge inches 1 1Oil Equalising inches - -

Capacity Index Limit 300~780 325~845Maximum Number of Connected Indoor Units 40 43

Outdoor Units RQCEQ816P3 RQCEQ848P3RQEQ180P3 RQEQ212P3 RQEQ212P3 RQEQ212P3 RQEQ212P3 RQEQ212P3 RQEQ212P3 RQEQ212P3

Capacity Nominal Cooling kW 81.60 84.80Nominal Heating kW 87.20 89.60

Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680Width mm 635 635 635 635 635 635 635 635Depth mm 765 765 765 765 765 765 765 765

Weight kg 175 179 179 179 179 179 179 179Air Flow Rate m3/sec 1.58 1.83 1.83 1.83 1.83 1.83 1.83 1.83Electrical Details Power Supply Phase 3ph

Hz 50V 400

Running Current amps 8.0+11.5+11.5+11.5 11.5+11.5+11.5+11.5Starting Current amps 4 4Fuse Rating amps 20 20 20 20 20 20 20 20

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 10.6 11.2 11.2 11.2 11.2 11.2 11.2 11.2Additional Charge kg data book

Sound Pressure dBA 58 60 60 60 60 60 60 60Piping Limits Maximum Length m 120

Maximum Vertical Rise m 50Piping Connections Liquid inches 3/4 3/4

Gas inches 1 3/8 1 3/8Discharge inches 1 1/8 1 1/8Oil Equalising inches - -

Capacity Index Limit 350~910 375~975Maximum Number of Connected Indoor Units 47 50

RQCEQ-P3

VRV III-Q Condensing Units – Heat Recovery

RQCEQ-P3 (71.2 to 74.4 kW)

RQCEQ-P3 (81.6 to 84.8 kW)

Page 48: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

46 VRV catalogue 2015

Mini Heat Pump VRVPlanning issues for small commercial or residential projects in towns and cities can now be

easy to overcome with a low height version of the mini VRV range – the VRV IV S-series –

available in 4 and 5HP. Featuring Variable Refrigerant Temperature control and offering the

flexibility to be connected to air curtains, air handing units and the Emura and Nexura fan

coils, the VRV IV S-series brings a whole new level of versatility to the VRV range.

VRVIII-S heat pump 48

Wide range of indoor units 49

1615

mm

823m

m

10/12 HP (Coming Autumn 2015)

8 HP (Coming Autumn 2015)

4/5/6 HP (New version available late 2015)

4/5 HP (Coming Autumn 2015)

Page 49: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

47VRV catalogue 2015

Min

i Hea

t Pum

p

Unseen in all the best places

Find out more at www.daikin.co.uk

Keep a low profileWe’re keeping a low profile with our new VRV IV S-series.Standing less than 1m from the ground including feet, our new compact VRV IV S-series is the lowest profile VRV unit in the market today. So it’s perfect for all kinds of tight spots and urban spaces. Available in 4 & 5 HP single phase, this lightweight single-fan unit joins our newly extended range of double-fan VRV IV S-series available in either single or 3-phase. All have front-blow, so can be located on a balcony or enclosed area. Plus every unit in the range now features VRV IV technology with variable refrigerant temperature control. So now you can get all the power of a VRV, in the smallest of spaces.

Daikin_miniVRV_ad_UK_260x180_UKversion.indd 1 16/02/2015 14:28:22

Page 50: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

48 VRV catalogue 2015

Outdoor Units RXYSQ4P8V1 RXYSQ5P8V1 RXYSQ6P8V1 RXYSQ4P8Y1 RXYSQ5P8Y1 RXYSQ6P8Y1Capacity Nominal Cooling kW 12.60 14.00 15.50 12.60 14.00 15.50

Nominal Heating kW 14.20 16.00 18.00 14.20 16.00 18.00Dimensions Height x Width x Depth mm 1345 x 900 x 320 1345 x 900 x 320 1345 x 900 x 320 1345 x 900 x 320 1345 x 900 x 320 1345 x 900 x 320Weight kg 120 120 120 120 120 120Air Flow Rate m3/sec 1.77 1.77 1.77 1.77 1.77 1.77Electrical Details Power Supply Phase 1ph 3ph

Hz 50 50V 230 400

Running Current amps 15.9 20.2 22.2 5.3 6.8 7.8Starting Current amps 4 4 4 4 4 4Fuse Rating amps 32 32 32 16 16 16

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 4.0Additional Charge kg data book

Sound Pressure dBA 50 51 53 50 51 53Sound Power dBA 66 67 69 66 67 69Piping Limits Maximum Length m 300

Maximum Vertical Rise m data bookPiping Connections Liquid inches 3/8 3/8 3/8 3/8 3/8 3/8

Gas inches 5/8 5/8 3/4 5/8 5/8 3/4Capacity Index Limit 50~130 62.5~162.5 70~182 50~130 62.5~162.5 70~182Maximum Number of Connected Indoor Units 8 10 12 8 10 12

Notes:The VRV III-S is highly space saving, featuring a slimmer and more compact outdoor unit compared to conventional models. Supplied in three sizes of 4 HP (11.2 kW), 5HP (14 kW) and 6HP (15.5 kW) with a single or three phase power supply. Compatible with the full range of existing VRV fan coil units providing a choice of 12 types and 72 models. Installation is improved by the completely new casing design of the outdoor unit with a footprint of just 320mm deep by 900mm wide, which reduces installation space requirements by over 40% (14.0kW model) and enables it to fit easily onto balconies and narrow ledges. Maximum piping length is 150m, total piping length is 300m and maximum vertical differential between outdoor and indoor units is 50m (40m when outdoor is below indoor units). The Daikin ‘Super Wiring’ system allows shared use of the wiring between indoor and outdoor units and the centralised remote control, the non polarity of the system obviating incorrect connection and reducing installation time.

Advanced technologies

Super aero grilleThe spiral shaped ribs are aligned with the direction of discharge flow in order to minimise turbulence and reduce noise.

1Smooth air inlet bell mouth and aero spiral fanThese features assist in significantly reducing noise. Guides are added to the bell mouth intake to reduce turbulence in the air flow generated by fan suction. The aero spiral fan features fan blades with bent blade edges, further reducing turbulence.

2

e-Bridge circuitPrevents accumulation of liquid refrigerant in the condenser. This results in more efficient use of the condenser surface under all conditions and leads in turn to better energy efficiency. Increased evaporative capacity stems from the newly developed refrigeration circuit, the SCe-bridge circuit, which adds super cooling prior to the expansion cycle. By adopting this circuit, the COPs in both cooling and heating have been drastically improved.

3

Conventional New

Escaping edges are sucked in by the bent blade edges, reducing overall turbulence.

Aero spiral fan blade tips

1

2

3

Updated VRV IV version including Variable Refrigerant Temperature control available during autumn 2015.

RXYSQ

VRV III Condensing Units – Heat Pump Inverter Mini

Page 51: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

49VRV catalogue 2015

Min

i Hea

t Pum

p

FVXG-K

FXFQ-AVRV indoor unit

FXSQ-PVRV indoor unit

FTXG-JA

BPMKS967B2

VRV Mini Heat pump systems can be configured to use the split fan coil range instead of VRV fan coils, ideally suited to residential projects with cooling requirements below 16kW.

VRV IV RYYQ-T Heat pumps can use a combination of both VRV and Split indoor units, a perfect combination for larger residential projects.

Wide range

of commercial or residential indoor unit combinations

Connectable to all Heat Pump VRV IV systems –

VRV can be combined with a wide range of stylish indoor units,

including the award winning Daikin Emura and radiant warmth

Nexura units.

FCQG-F

FBQ-C BPMKS967B2

FTXG-JA – Daikin Emura

FVXG-K – Nexura BPMKS967B2

Connectable indoor units 15 class 20 class 25 class 35 class 42 class 50 class 60 class 71 classDaikin Emura – Wall mounted unit FTXG20LW

FTXG20LSFTXG25LWFTXG25LS

FTXG35LWFTXG35LS

FTXG50LWFTXG50LS

Wall mounted unit CTXS15K FTXS20K FTXS25K FTXS35K FTXS42K FTXS50K FTXS60G FTXS71GNexura – Floor standing unit FVXG25K FVXG35K FVXG50K

Branch provider BPMKS967B2 BPMKS967B3Connectable indoor units 1~2 1~3Max. indoor unit connectable capacity 14.2 20.8Max. connectable combination 71+71 60+71+71Dimensions H x W x D mm 180 x 294 x 350Weight kg 7 8

Split indoor units offer a high quality award winning look and feel to spaces with a high design aesthetic requirement.

Both systems require a BPMK expansion valve box in order to attach split fan coil units.

When connecting Split indoor units to a VRV system, some design considerations are required to be taken into consideration, we recommend contacting your local Daikin representative who will be happy to help you select the most suitable system.

BPMKS box provides expansion valves and communication devices that allow split units on VRV systems.

Page 52: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

50 VRV catalogue 2015

Water cooled VRVRWEYQ-T8

The new VRV IV features are already available on water cooled VRV systems including:

> Variable Refrigerant Temperature – delivering far higher efficiency than any other comparable system and ensuring comfort by raising off coil temperatures, Variable Refrigerant Temperature control delivers a leap forwards in VRV technology.

> Configurator – Simplified commissioning: graphical interface to configure, commission and upload system settings. Manage systems over multiple sites, saves time and reduces errors during set-up and commissioning.

> The standard model is now capable of accepting geothermal water temperatures (Down to -10 Deg C with glycol)

> Inverter water pump controller (available on request)

> Connect to AHU applications and Heat Reclaim Ventilation devices

Ideal for large buildings

VRV-W systems are capable of coping with water pressures of 2MPa and pipework lengths of up to 120m length from condenser to fan coils.

Water cooled VRV uses water as its source of heat. This enables not just heat

recovery on each system, but also heat recovery between different systems,

maximising efficiency. Additionally there is no defrost required on these units

meaning heating comfort is maintained even during cold spells.

Water cooled VRV Heat Recovery 51

VRV IV water cooled Condensing Units 52

Now it’s even possible to connect a water cooled VRV system with VRV IV BS boxes, including the small, light Multi BS boxes designed to offer the largest and most flexible range of design and installation options available.*

* VRV IV single and multi BS Box connectivity coming spring 2015, please speak to your local Daikin representative to ensure your system design is available for delivery when your project starts

Page 53: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

51VRV catalogue 2015

Wat

er c

oole

d

First stage heat recovery

The first stage only applies to heat recovery units transferring heat from cooling indoor units to areas requiring heating. This maximises energy efficiency and reduces electricity costs.

Second stage heat recovery

Heat recovery is also available on heat pump units, in which the second stage is achieved within the water loop

between the water cooled outdoor units. In addition, heat recovery occurs between the water-cooled outdoor units connected to the same loop and these systems exchange heat via the water.

This two-stage heat recovery substantially improves energy efficiency. It is therefore the perfect solution for modern office buildings where some areas may require cooling, even in winter, depending on the amount of sunshine and number of individuals in the building.

Water cooled

VRV Heat Recovery

VRV-W benefits from a 2-stage heat recovery facility, which enables

simultaneous heating and cooling within the refrigerant system.

Heat recovery between indoor units

All indoor units in cooling mode

Indoor units mainly cooling, partly heating

Full heat recovery

Indoor units mainly heating, partly cooling

All indoor units in heating mode

Heat

rejected to

loop

Heat partly

rejected to loop

Partly heat absorption

from loop

Heat absorption

from loop

VRV-W

VRV-W

VRV-W

VRV-W

VRV-W

Heat recovery between outdoor units (Heat recovery and heat pump)

* Above system configurations are for illustration purposes only.

Cooling tower (Closed type), boiler

Heat rejected to loop

Heat rejected to loop

Heat absorbed from loop

Heat absorbed from loop

VRV-W

VRV-W

VRV-W

VRV-W

Page 54: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

52 VRV catalogue 2015

Outdoor Units RWEYQ8T8 RWEYQ10T8 RWEYQ16T8 RWEYQ18T8 RWEYQ20T8 RWEYQ24T8RWEYQ8T8 RWEYQ8T8 RWEYQ8T8 RWEYQ10T8 RWEYQ10T8 RWEYQ10T8 RWEYQ8T8 RWEYQ8T8 RWEYQ8T8

Capacity Nominal Cooling kW 22.40 28.00 44.80 50.40 56.00 67.20Nominal Heating kW 25.00 31.50 50.00 56.50 63.00 75.00

EER 5.07 4.56 5.07 4.77 4.56 5.07COP 5.94 5.25 5.94 5.53 5.25 5.94Dimensions Height mm 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000

Width mm 780 780 780 780 780 780 780 780 780 780 780Depth mm 550 550 550 550 550 550 550 550 550 550 550

Weight kg 137 137 137 137 137 137 137 137 137 137 137Electrical Details Power Supply Phase /Hz/v 3ph / 50 / 400

Running Current amps 7.2 9.5 14.4 16.7 19.0 21.6Starting Current amps 4 4 4 4 4 4Fuse Rating amps 20 20 32 32 32 50

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 3.5 4.2 3.5 3.5 3.5 4.2 4.2 4.2 3.5 3.5 3.5Additional Charge kg data book data book data book data book data book data book

Sound Pressure dBA 50 51 53 54 54 55Piping Limits Maximum Length m 120 120 120 120 120 120

Maximum Vertical Rise m 50 50 50 50 50 50Piping Connections Liquid inches 3/8 3/8 1/2 5/8 5/8 3/4

Gas inches 3/4 7/8 1 1/8 1 1/8 1 1/8 1 3/8Discharge pipe size - Heat Recovery Only inches - - - - - -Capacity Index Limit 100~260 125~325 200~520 225~585 250~650 300~780Maximum Number of Connected Indoor Units 36 36 36 36 36 36

Notes:Daikin have introduced the new VRV IV Water Cooled condensing unit to compliment the rest of the VRV range. The water cooled system has a number of advantages over an air cooled system:

• suitable for tall multi-storied buildings due to no limitations of water piping length• wide operation range with inlet water temperatures of -10 - 45°C• suitable for use with open and closed loop ground source systems on request• the system offers greater efficiency in heating mode as there is no defrost cycle required for the water loop• greater efficiencies than air cooled systems

Notes:The VRV IV Water Cooled system is supplied as a common unit and can be used in either heat pump and heat recovery modes, from size 10 to size 30 all using a three phase power supply. The 30 hp system can connect to up to 36 indoor units. The system is fully compatible with the full range of existing VRV fan coils and controls packages.The condensing unit is small with a foot print of 780 x 550 mm and a height of 1000 mm. Running quality with a sound pressure level of 51dB(A), it should be installed in a plant room.

Outdoor Units RWEYQ26T8 RWEYQ28T8 RWEYQ30T8RWEYQ8T8 RWEYQ8T8 RWEYQ10T8 RWEYQ8T8 RWEYQ10T8 RWEYQ10T8 RWEYQ10T8 RWEYQ10T8 RWEYQ10T8

Capacity Nominal Cooling kW 72.80 78.40 84.00Nominal Heating kW 81.50 88.00 94.50

EER 4.86 4.69 4.56COP 5.65 5.43 5.25Dimensions Height mm 1000 1000 1000 1000 1000 1000 1000 1000 1000

Width mm 780 780 780 780 780 780 780 780 780Depth mm 550 550 550 550 550 550 550 550 550

Weight kg 137 137 137 137 137 137 137 137 137Electrical Details Power Supply Phase 3ph / 50 / 400

Running Current amps 23.9 26.2 28.5Starting Current amps 4.0 4.0 4.0Fuse Rating amps 50 50 50

Refrigerant Circuit Refrigerant Type R410aRefrigerant Charge kg 4 4 4 4 4 4 4 4 4Additional Charge kg data book

Sound Pressure dBA 55 55 56Piping Limits Maximum Length m 120 120 120

Maximum Vertical Rise m 50 50 50Piping Connections Liquid inches 3/4 3/4 3/4

Gas inches 1 3/8 1 3/8 1 3/8Discharge pipe size - Heat Recovery Only inches - - -Capacity Index Limit 325~845 350~910 375~975Maximum Number of Connected Indoor Units 36 36 36

Heat Pump and Heat Recovery RWEYQ-T8

VRV IV Water Cooled Condensing Units

RWEYQ-T8 (up to 24 HP)

RWEYQ-T8 (26 to 30 HP)

Page 55: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

The VRV IV Water Cooled system is supplied as a common unit and can be used in either heat pump and heat recovery modes, from size 10 to size 30 all using a three phase power supply. The 30 hp system can connect to up to 36 indoor units. The system is fully compatible with the full range of existing VRV fan coils and controls packages.The condensing unit is small with a foot print of 780 x 550 mm and a height of 1000 mm. Running quality with a sound pressure level of 51dB(A), it should be installed in a plant room.

Wat

er c

oole

d

Page 56: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

54 VRV catalogue 2015

To keep pace with the technical advances of modern air conditioning and meet the urgent need to achieve higher energy efficiencies and manage fuel costs, Daikin invests heavily in the research and production of similarly advanced and comprehensive methods of control.

In buildings with multiple air conditioning units that operate for long hours, system efficiency is of paramount importance in reducing energy consumption.

Maximising efficiency demands maximum control of all aspects of system operation including round the clock monitoring, preventative maintenance and fault predictive analysis, plus rapid response in the event of malfunctions.

Daikin manufactures and markets many state-of-the-art computerised control systems that offer building owners, landlords and tenants comprehensive system cover, backed up by vital data on operational performance and running costs.

ControlsAny air conditioning system will only operate as efficiently as its

control system allows. The importance of precise, user-friendly

equipment is as relevant to simple residential room temperature

controls as it is to full remote monitoring and regulation of large

scale commercial buildings.

Individual control systems 55

Interfaces 56

Centralised control systems 58

Management control 59

DNSS 60

Control options for air handlings applications 61

Page 57: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

55VRV catalogue 2015

Cont

rols

A series of energy saving functions can be individually selected:

> Temperature range limit> Setback function> Presence and floor sensor connection

(available on new round flow cassette)> kWh indication> Set temperature auto reset> Off timer

Temperature range limit avoids excessive heating or cooling

Save energy by restricting the lower temperature limit in cooling and upper temperature limit in heating mode.

Note: Also available in auto cooling/heating change over mode.

kWh indication keeps track of your consumption

The kWh indication shows an indicative electricity consumption over the last day/month/year.

Other functions

> Up to 3 independent schedules can be set, so the user can easily change the schedule throughout the year (e.g. Summer, winter, mid-season)

> Ability to restrict individual menu functions> Easy to use: all main functions directly accessible> Easy setup: clear graphical user interface for

advanced menu settings> Real time clock with auto update to daylight

saving time> Supports multiple languages (English, German,

Dutch, Spanish, Italian, Portuguese, French, Greek, Russian, Turkish, Polish)

> Built-in backup power: when a power failure occurs all settings remain stored up to 48 hours

Individual control systems

BRC1E52A/BWired remote control

> Easy to use: all main functions directly accessible

> Energy saving functions: set temperature auto reset, set temperature range limit

> Easy setup: improved graphical user interface for advanced menu settings

> Real time clock with auto update to daylight saving time

> Schedule timer with holiday setting, improved weekly timer and home leave operation

> Supports multiple languages (English, German, Dutch, Spanish, Italian, Portuguese, French, Greek, Russian, Turkish)

> Automatically displays installer contact in event of a malfunction

BRC4*/BRC7*Infrared remote control

> Operation buttons: ON/OFF, timer mode start /stop, timer mode on/off, programme time, temperature setting, air flow direction (1), operating mode, fan speed control, filter sign reset (2), inspection (2)/test indication (2)

> Display: operating mode, battery change, set temperature, air flow direction (1), programmed time, fan speed, inspection/test operation (2)

1. Not applicable for FXDQ, FXSQ, FXNQ, FBDQ, FDXS, FBQ

2. For FX** units only3. For all features of the remote control,

refer to the operation manual

BRC2C51Simplified remote control

> New controller design with symbol driven rather than text menus

> Options with or without heat/cool button to suit customers priorities

> Option for direct key card and / or window switch dry contacts (BRP7A51)

> Key card / window switch settings to allow different strategies

> Set your own control rules> Run on timer after guest leaves (0-10 mins)> Reset to pre-defined setpoint and mode

after X hours or restore last settings> Lock on/off button after room vacated> Switch off/restart settings for window

switch activation> Available in standard white, polished

chrome, brushed chrome and polished brass

NEW

Page 58: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

56 VRV catalogue 2015

Interfaces

The following interfaces enable the integration of RA, Sky Air,

VRV, Daikin Altherma Flex and Air Handling Units in building

management systems (BMS) or home automation systems.

RTD-20> Advanced integration of Sky Air, VRV,

VAM/VKM and air curtains> Clone or independent zone control> CO

2 sensor for VAM fresh air control

> Save on running costs via – pre/post and trade mode – set point limitation – overall shut down – PIR sensor for adaptive deadband

RTD-RA> Modbus interface for monitoring and control

of residential indoor units

RTD-NET > Modbus interface for monitoring and control

of Sky Air, VRV, VAM and VKM> Duty/standby function for server rooms

RTD-10 Advanced integration into BMS of Sky Air, VRV, VAM and VKM through either: > Modbus> Voltage (0-10V)> Resistance

RTD-HO> Modbus interface for monitoring and

control of Sky Air, VRV, VAM and VKM> Intelligent hotel room controller

RTD-W> Modbus interface for monitoring and

control of Daikin Altherma Flex Type, VRV HT hydrobox and chillers

BACnet InterfaceIntegrated control system for seamless connection between VRV, Applied Systems and BMS systems

> Interface for BMS system> Communication via BACnet protocol (connection via Ethernet) > Unlimited site size> Easy and fast installation> PPD data is available on BMS system (only for VRV)

LonWorks InterfaceOpen network integration of VRV monitoring and control functions into LonWorks networks

> Interface for Lon connection to LonWorks networks> Communication via Lon protocol (twisted pair wire)> Unlimited site size> Quick and easy installation

Page 59: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

57VRV catalogue 2015

Cont

rols

KNX interface line-upThe integration of Daikin indoor units through the KNX interface allows monitoring and control of several devices, such as lights and shutters, from one central controller. One particularly important feature is the ability to programme a ‘scenario’ – such as “Home leave” – in which the end-user selects a range of commands to be executed simultaneously once the scenario is selected. For instance in “Home leave”, the air conditioner is off, the lights are turned off, the shutters are closed and the alarm is on.

KLIC-DD Size 90x60x35mm KLIC-DI Size 45x45x15mm

Split Sky Air VRVBasic controlOn/Off 4 4 4

Mode Auto, heat, dry, fan, cool Auto, heat, dry, fan, cool Auto, heat, dry, fan, coolTemperature 4 4 4

Fan speed levels 3 or 5 + auto 2 or 3 2 or 3Swing Stop or movement Stop or movement Swing or fixed positions (5)

Advanced functionalitiesError management Communication errors, Daikin unit errorsScenes 4 4 4

Auto switch off 4 4 4

Temperature limitation 4 4 4

Initial configuration 4 4 4

Master and slave configuration 4 4

KNX interface for

Integration of Split, Sky Air and VRV in HA/BMS systemsConnect split indoor units to KNX interface for Home Automation system

Concept

tv

DomoticaController

shutter control

houselight

Interface Daikin protocol/ KNX

Connect Sky Air / VRV indoor units to KNX interface for BMS integration

Concept

DomoticaController

light

shutter control

shop

Interface Daikin protocol/ KNX

tv

Wireless room temperature sensor – K.RSS > Flexible and easy installation> Accurate temperature measurement

thanks to flexible placement of the sensor

> Room temperature is sent to the indoor unit every 90 seconds or if the temperature difference is 0.2°C or larger

Wireless room temperature sensor kit (K.RSS)WIRELESS ROOM TEMPERATURE RECEIVER WIRELESS ROOM TEMPERATURE SENSOR

Dimensions mm 50 x 50 ø 75Weight g 40 60Power supply 16VDC, max. 20 mA N/ABattery life N/A +/- 3 yearsBattery type N/A 3 Volt Lithium batteryMaximum range m 10Operation range °C 0~50Communication Type RF

Frequency MHz 868.3

CONNECTION DIAGRAM Daikin indoor unit PCB (FXSQ-P example)

Air sensor – X16A, X19

Power supply – X35, X13

RF SENDERRF RECEIVER

> No need for wiring > No need to drill holes> Ideal for refurbishment

KLIC-DD / KLIC-DI

KNX interface

Page 60: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

58 VRV catalogue 2015

Centralised

control systems

Detailed and easy monitoring and operation of VRV systems (max. 2 X 64 groups/indoor units)

System layout

> Up to 2 x 64 indoor units can be controlled> Touch panel (full colour LCD via icon display)

Management

> Easy management of electricity consumption> Enhanced history function

Control

> Individual control (set point, start/stop, fan speed) (max. 2 x 64 groups/indoor units)

> Set back schedule > Enhanced scheduling function (8 schedules, 17 patterns)> Flexible grouping in zones> Yearly schedule> Fire emergency stop control> Interlocking control> Increased HRV monitoring and control function> Automatic cooling/heating change-over> Heating optimisation> Temperature limit> Password security: 3 levels (general, administration and service)> Quick selection and full control> Simple navigation

Monitoring

> Visualisation via Graphical User Interface (GUI)> Icon colour display change function> Indoor units operation mode> Indication filter replacement

Cost performance

> Free cooling function> Labour saving> Easy installation> Compact design: limited installation space> Overall energy saving

Open interface

> Communication to any third party controller (domotics, BMS, etc.) is possible via open interface (http option)

Connectable to

> VRV> HRV> Sky Air (via interface adapter)> Split (via interface adapter)

Public line

Air conditioning Network Service System

third party controller (domotics, BMS, etc.)

Ethernet

DIII-NET

Forced OFF contact input

Onboard

modem

Fire alarm

DIII-NET Allows monitoring/control of up to 64 units (groups) of A/Cs and

equipment

DIII-NET PLUS adapter

HRVIndoor units

RS-232C

Indoor units

DCS601C51

HRV

Page 61: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

59VRV catalogue 2015

Cont

rols

225

Cont

rol S

yste

ms

• Price competitive mini BMS

• Cross-pillar integration of Daikin products

• Integration of third party equipment

Plug & play

Mini Building Management System NEW

User friendliness › Intuitive user interface › Visual lay out view and direct access to indoor unit main funtions

› All functions direct accessible via touch screen or via web interface

Smart energy management

› Monitoring if energy use is according to plan › Helps to detect origins of energy waste › Powerful schedules guarantee correct operation throughout the year

› Save energy by interlocking A/C operation with other equiment such as heating

Flexibility

› Cross-pillar integration (heating, air conditioning, applied systems, refrigeration, air handling units)

› BACnet protocol for 3rd party products integration › I/O for integration of equipment such as lights, pumps… on WAGO modules

› Modular concept for small to large applications › Control up to 512 indoor unit groups via one ITM and combine multiple ITM via the web interface

Easy servicing and commissioning

› Remote refrigerant containment check preventing on site visit

› Simplifi ed troubleshooting › Save time on commissioning thanks to the pre-commissioning tool

› Auto registration of indoor units

Functions overview

Languages › English

› French

› German

› Italian

› Spanish

› Dutch

› Portuguese

Management › Web access

› Power Proportional

Distribution (option)

› Operational history

(malfunctions, operation hours, …)

› Smart energy management

- monitor if energy use is

according to plan

- detect origins of energy

waste

› Setback function

› Sliding temperature

System layout › Up to 2,560 unit groups can

be controlled

(ITM plus Integrator + 7 iPU

(incl. iTM adaptor)

› Ethernet TCPIP

Control › Individual control

(2,560 groups)

› Schedule setting (Weekly

schedule, yearly calender,

seasonal schedule)

› Interlock control

› Setpoint limitation

› Temperature limit

Connectable to- DX Split, Sky Air, VRV

- Chillers (via POL638.70 controller)

- Daikin AHU

- Fan coils

- Daikin Altherma Flex type

- LT and HT hydroboxes

- Air curtains

- WAGO I/O, AO and PI

- BACnet protocol

WAGO Interface › Modular integration of 3rd

party equipment

- WAGO coupler (interface

between WAGO and Modbus)

- Di module

- Do module

- Ai module

- Thermistor module

NEW

NEW

NEW

NEW

Flexibility in size

From 64 up to ∞ number

of groups

Split Fan coils Chillers and AHU Refrigeration

ECPEN15-200.indd 225 12/02/15 11:47

225

Cont

rol S

yste

ms

• Price competitive mini BMS

• Cross-pillar integration of Daikin products

• Integration of third party equipment

Plug & play

Mini Building Management System NEW

User friendliness › Intuitive user interface › Visual lay out view and direct access to indoor unit main funtions

› All functions direct accessible via touch screen or via web interface

Smart energy management

› Monitoring if energy use is according to plan › Helps to detect origins of energy waste › Powerful schedules guarantee correct operation throughout the year

› Save energy by interlocking A/C operation with other equiment such as heating

Flexibility

› Cross-pillar integration (heating, air conditioning, applied systems, refrigeration, air handling units)

› BACnet protocol for 3rd party products integration › I/O for integration of equipment such as lights, pumps… on WAGO modules

› Modular concept for small to large applications › Control up to 512 indoor unit groups via one ITM and combine multiple ITM via the web interface

Easy servicing and commissioning

› Remote refrigerant containment check preventing on site visit

› Simplifi ed troubleshooting › Save time on commissioning thanks to the pre-commissioning tool

› Auto registration of indoor units

Functions overview

Languages › English

› French

› German

› Italian

› Spanish

› Dutch

› Portuguese

Management › Web access

› Power Proportional

Distribution (option)

› Operational history

(malfunctions, operation hours, …)

› Smart energy management

- monitor if energy use is

according to plan

- detect origins of energy

waste

› Setback function

› Sliding temperature

System layout › Up to 2,560 unit groups can

be controlled

(ITM plus Integrator + 7 iPU

(incl. iTM adaptor)

› Ethernet TCPIP

Control › Individual control

(2,560 groups)

› Schedule setting (Weekly

schedule, yearly calender,

seasonal schedule)

› Interlock control

› Setpoint limitation

› Temperature limit

Connectable to- DX Split, Sky Air, VRV

- Chillers (via POL638.70 controller)

- Daikin AHU

- Fan coils

- Daikin Altherma Flex type

- LT and HT hydroboxes

- Air curtains

- WAGO I/O, AO and PI

- BACnet protocol

WAGO Interface › Modular integration of 3rd

party equipment

- WAGO coupler (interface

between WAGO and Modbus)

- Di module

- Do module

- Ai module

- Thermistor module

NEW

NEW

NEW

NEW

Flexibility in size

From 64 up to ∞ number

of groups

Split Fan coils Chillers and AHU Refrigeration

ECPEN15-200.indd 225 12/02/15 11:47

225

Cont

rol S

yste

ms

• Price competitive mini BMS

• Cross-pillar integration of Daikin products

• Integration of third party equipment

Plug & play

Mini Building Management System NEW

User friendliness › Intuitive user interface › Visual lay out view and direct access to indoor unit main funtions

› All functions direct accessible via touch screen or via web interface

Smart energy management

› Monitoring if energy use is according to plan › Helps to detect origins of energy waste › Powerful schedules guarantee correct operation throughout the year

› Save energy by interlocking A/C operation with other equiment such as heating

Flexibility

› Cross-pillar integration (heating, air conditioning, applied systems, refrigeration, air handling units)

› BACnet protocol for 3rd party products integration › I/O for integration of equipment such as lights, pumps… on WAGO modules

› Modular concept for small to large applications › Control up to 512 indoor unit groups via one ITM and combine multiple ITM via the web interface

Easy servicing and commissioning

› Remote refrigerant containment check preventing on site visit

› Simplifi ed troubleshooting › Save time on commissioning thanks to the pre-commissioning tool

› Auto registration of indoor units

Functions overview

Languages › English

› French

› German

› Italian

› Spanish

› Dutch

› Portuguese

Management › Web access

› Power Proportional

Distribution (option)

› Operational history

(malfunctions, operation hours, …)

› Smart energy management

- monitor if energy use is

according to plan

- detect origins of energy

waste

› Setback function

› Sliding temperature

System layout › Up to 2,560 unit groups can

be controlled

(ITM plus Integrator + 7 iPU

(incl. iTM adaptor)

› Ethernet TCPIP

Control › Individual control

(2,560 groups)

› Schedule setting (Weekly

schedule, yearly calender,

seasonal schedule)

› Interlock control

› Setpoint limitation

› Temperature limit

Connectable to- DX Split, Sky Air, VRV

- Chillers (via POL638.70 controller)

- Daikin AHU

- Fan coils

- Daikin Altherma Flex type

- LT and HT hydroboxes

- Air curtains

- WAGO I/O, AO and PI

- BACnet protocol

WAGO Interface › Modular integration of 3rd

party equipment

- WAGO coupler (interface

between WAGO and Modbus)

- Di module

- Do module

- Ai module

- Thermistor module

NEW

NEW

NEW

NEW

Flexibility in size

From 64 up to ∞ number

of groups

Split Fan coils Chillers and AHU Refrigeration

ECPEN15-200.indd 225 12/02/15 11:47

225

Cont

rol S

yste

ms

• Price competitive mini BMS

• Cross-pillar integration of Daikin products

• Integration of third party equipment

Plug & play

Mini Building Management System NEW

User friendliness › Intuitive user interface › Visual lay out view and direct access to indoor unit main funtions

› All functions direct accessible via touch screen or via web interface

Smart energy management

› Monitoring if energy use is according to plan › Helps to detect origins of energy waste › Powerful schedules guarantee correct operation throughout the year

› Save energy by interlocking A/C operation with other equiment such as heating

Flexibility

› Cross-pillar integration (heating, air conditioning, applied systems, refrigeration, air handling units)

› BACnet protocol for 3rd party products integration › I/O for integration of equipment such as lights, pumps… on WAGO modules

› Modular concept for small to large applications › Control up to 512 indoor unit groups via one ITM and combine multiple ITM via the web interface

Easy servicing and commissioning

› Remote refrigerant containment check preventing on site visit

› Simplifi ed troubleshooting › Save time on commissioning thanks to the pre-commissioning tool

› Auto registration of indoor units

Functions overview

Languages › English

› French

› German

› Italian

› Spanish

› Dutch

› Portuguese

Management › Web access

› Power Proportional

Distribution (option)

› Operational history

(malfunctions, operation hours, …)

› Smart energy management

- monitor if energy use is

according to plan

- detect origins of energy

waste

› Setback function

› Sliding temperature

System layout › Up to 2,560 unit groups can

be controlled

(ITM plus Integrator + 7 iPU

(incl. iTM adaptor)

› Ethernet TCPIP

Control › Individual control

(2,560 groups)

› Schedule setting (Weekly

schedule, yearly calender,

seasonal schedule)

› Interlock control

› Setpoint limitation

› Temperature limit

Connectable to- DX Split, Sky Air, VRV

- Chillers (via POL638.70 controller)

- Daikin AHU

- Fan coils

- Daikin Altherma Flex type

- LT and HT hydroboxes

- Air curtains

- WAGO I/O, AO and PI

- BACnet protocol

WAGO Interface › Modular integration of 3rd

party equipment

- WAGO coupler (interface

between WAGO and Modbus)

- Di module

- Do module

- Ai module

- Thermistor module

NEW

NEW

NEW

NEW

Flexibility in size

From 64 up to ∞ number

of groups

Split Fan coils Chillers and AHU Refrigeration

ECPEN15-200.indd 225 12/02/15 11:47

Mini Building Management SystemNEW

User friendly

> Intuitive user interface> Visual layout view and direct access to indoor

unit main functions> All functions direct accessible via touch screen

or via web interface

Smart energy management

> Monitoring if energy use is according to plan> Helps to detect origins of energy waste> Powerful schedules guarantee correct operation

throughout the year> Save energy by interlocking A/C operation

with other equipment such as heating

Flexibility

> Cross-pillar integration (heating, air conditioning, applied systems, refrigeration, air handling units)

> BACnet protocol for 3rd party products integration

> I/O for integration of equipment such as lights, pumps… on WAGO modules

> Modular concept for small to large applications> Control up to 512 indoor unit groups via one ITM

and combine multiple ITM via the web interface

Easy servicing and commissioning

> Remote refrigerant containment check preventing on site visit

> Simplified troubleshooting> Save time on commissioning thanks to the

pre-commissioning tool> Auto registration of indoor units

NEW

NEW

225

Cont

rol S

yste

ms

• Price competitive mini BMS

• Cross-pillar integration of Daikin products

• Integration of third party equipment

Plug & play

Mini Building Management System NEW

User friendliness › Intuitive user interface › Visual lay out view and direct access to indoor unit main funtions

› All functions direct accessible via touch screen or via web interface

Smart energy management

› Monitoring if energy use is according to plan › Helps to detect origins of energy waste › Powerful schedules guarantee correct operation throughout the year

› Save energy by interlocking A/C operation with other equiment such as heating

Flexibility

› Cross-pillar integration (heating, air conditioning, applied systems, refrigeration, air handling units)

› BACnet protocol for 3rd party products integration › I/O for integration of equipment such as lights, pumps… on WAGO modules

› Modular concept for small to large applications › Control up to 512 indoor unit groups via one ITM and combine multiple ITM via the web interface

Easy servicing and commissioning

› Remote refrigerant containment check preventing on site visit

› Simplifi ed troubleshooting › Save time on commissioning thanks to the pre-commissioning tool

› Auto registration of indoor units

Functions overview

Languages › English

› French

› German

› Italian

› Spanish

› Dutch

› Portuguese

Management › Web access

› Power Proportional

Distribution (option)

› Operational history

(malfunctions, operation hours, …)

› Smart energy management

- monitor if energy use is

according to plan

- detect origins of energy

waste

› Setback function

› Sliding temperature

System layout › Up to 2,560 unit groups can

be controlled

(ITM plus Integrator + 7 iPU

(incl. iTM adaptor)

› Ethernet TCPIP

Control › Individual control

(2,560 groups)

› Schedule setting (Weekly

schedule, yearly calender,

seasonal schedule)

› Interlock control

› Setpoint limitation

› Temperature limit

Connectable to- DX Split, Sky Air, VRV

- Chillers (via POL638.70 controller)

- Daikin AHU

- Fan coils

- Daikin Altherma Flex type

- LT and HT hydroboxes

- Air curtains

- WAGO I/O, AO and PI

- BACnet protocol

WAGO Interface › Modular integration of 3rd

party equipment

- WAGO coupler (interface

between WAGO and Modbus)

- Di module

- Do module

- Ai module

- Thermistor module

NEW

NEW

NEW

NEW

Flexibility in size

From 64 up to ∞ number

of groups

Split Fan coils Chillers and AHU Refrigeration

ECPEN15-200.indd 225 12/02/15 11:47

Functions overview Management

> Web access> Power Proportional

Distribution (option)> Operational history

(malfunctions, operation hours, …)

> Smart energy management – monitor if energy use is

according to plan – detect origins of energy

waste> Setback function> Sliding temperature

Control

> Individual control> Schedule setting (weekly

schedule, yearly calender, seasonal schedule)

> Interlock control> Setpoint limitation> Temperature limit

Connectable to

> DX Split, Sky Air, VRV> Chillers (via POL638.70 controller)> Daikin AHU> Fan coils> Daikin Altherma Flex type> LT and HT hydroboxes> Air curtains> WAGO I/O, AO and PI> BACnet protocol> WAGO Interface

NEW

NEW

Page 62: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

60 VRV catalogue 2015

* A contract with Daikin is necessary for applying Energy-saving Air conditioning Network Service System. If you would like an estimation, please contact us.

DNSS ENERGY SAVING SERVICEDNSS MONITORING SERVICE

Comfort maintained

Data

WWW.

1 Data transmission Air conditioners running information and other necessary data are collected and compiled, and sent to the centre. Advance failure forecasts and monitoring data for accidental problems are transmitted.

3 Data analysis & system monitoring Reporting data is reviewed and system is monitored 24/7 for any occurrences.

2 Daikin Remote Monitoring Centre

Daikin's control implemented

Information to customers, service company

Weather information

energy-saving control determinationOperating information is analysed, and the optimum energy-saving control settings are calculated according to weather data for the region.

OPTION:

Energy-saving Report Maintenance ReportMalfunction and prediction call

DNSS

Daikin Network Service System

The challenge for technical managers is to safeguard the long term optimal operation of an air conditioning system, without incurring huge costs along the way.

The Daikin Network Service System (DNSS) operates via an internet connection between the air conditioning system and Daikin’s Remote Monitoring Centre.

Expert service engineers monitor the operating status of the entire system non-stop all through the year.

The DNSS monitoring service prevents troubles and prolongsthe life of your equipment, by enabling you to predict faults andmake technical decisions based on accurate data analysis.

This innovative solution helps you to minimise equipment downtime and control cost without sacrificing comfort levels.

DNSS is also supported by the optional DNSS energysaving service, which enables you to optimise energy efficiency.

Page 63: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

61VRV catalogue 2015

Cont

rols

Ts = Air suction temperatureTd = Air discharge temperatureTr = Room temperature

Te = Evaporating temperatureAHU = Air Handling UnitDDC = Digital Display Controller

Control options

for air handling applications

In order to maximise installation flexibility, 4 types of control systems are offered

Possibility X (Td/Tr control):

Air temperature control via an external DDC controller (field supplied)Room temperature is controlled as a function of the air handling unit suction or discharge air (customer selection). The DDC controller translates the temperature difference between set point and air suction temperature (or air discharge temperature or room temperature) into a reference voltage (0-10V) which is transferred to the Daikin control box (EKEQFCBA). This reference voltage will be used as the main input value for the compressor frequency control.

Possibility Y (Te/Tc control):

By fixed evaporating temperatureA fixed target evaporating temperature of between 3°C and 8°C can be set by the customer. In this case, room temperature is only indirectly controlled. The cooling load is determined from the actual evaporating temperature (i.e. load to the heat exchanger). A Daikin wired remote controller (BRC1D52 or BRC1E52A/B - optional) can be connected for error indication.

Possibility Z (Td/Tr control):

Using Daikin wired remote controller (BRC1D52 or BRC1E51A/B – optional)Set point can be fixed via standard Daikin wired remote controller. Remote ON/OFF can be achieved by an optional adapter KRP4A51. No external DDC controller should be connected. The cooling load is determined from the air suction temperature and set point on the Daikin controller.

W: Control of air temperature

(Td, Ts or Tr – all field supplied sensors) With external controller (DDC) using a proportional 0~10V algorithm for capacity control.

DDC

Ts

TR

Te

AHU

Room

Td

Daikincontrol box:

EKEQFCB

Ts

TR

Te

AHU

Room

TdDaikin

control box:EKEQFCB

BRC1D52BRC1E52A/B

BRC1D52BRC1E52A/B

Ts

TR

Te

AHU

Room

Td

Daikincontrol box:

EKEQDCB EKEQMCB

KRP4A51

ON / OFF

* EKEQMCB (for ‘multi’ application)

Option kit Features

Possibility xEKEQFCB

Field supplied DDC controller is requiredTemperature control using air suction or air discharge temperature

Possibility y Using fixed evaporating temperature, no set point can be set using remote controller

Possibility z EKEQDCB EKFQMCB*

Using Daikin wired remote controller BRC1D52 or BRC1E52A/BTemperature control using air suction temperature

NEWTs

TR

Te

AHU

Room

Td

DDC

Page 64: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

62 VRV catalogue 2015

The Daikin VRV indoor unit range is one of the widest on the market, offering no less than 26 stylish and elegant models in 116 different variants – all designed to maximise comfort, minimise operating noise and simplify installation and servicing. Options include ceiling mounted cassettes, concealed ceiling, ceiling suspended, wall mounted and floor standing models.

The Roundflow cassette now includes an optional auto cleaning filter, which automatically cleans itself daily, leading to yearly energy savings of up to 50%. Dust from the filter is collected in the unit for removal simply by vacuum cleaning.

Designed to fit rooms of any size and shape, Daikin indoor units are also user friendly, ultra reliable, easy to control and quiet in operation.

As a market leader, Daikin has ensured that all indoors units comply with the Ecodesign legislation by adopting DC fans in all indoor units, improving their energy efficiency even further.

Indoor unitsAs many as 64 separate indoor units can be operated from the

single refrigerant circuit of a 54 HP VRV heat pump system.

Roundflow cassette – FXFQ-A 63

Fully flat cassette – FXZQ-A 64

2-way blow ceiling mounted cassette – FXCQ-A 66

Ceiling mounted corner cassette – FXKQ-MA 67

Ceiling suspended unit – FXHQ-A 68

4-way blow ceiling suspended unit – FXUQ-A 69

Small concealed ceiling unit – FXDQ-M9 70

Slim concealed ceiling unit – FXDQ-A 71

Concealed ceiling unit (high static pressure) – FXSQ-A 72

Concealed ceiling unit (high static pressure) – FXMQ-P7 73

Large concealed ceiling unit – FXMQ-MA 74

Wall mounted unit – FXAQ-P 75

Floor standing unit – FXLQ-P 76

Concealed low wall ducted unit – FXNQ-A 77

Hot water generation (VRV heat pump) – HXY-A 78

Hot water generation (VRV heat recovery) – HXHD-A / HXY-A 79

Air curtains for commercial applications – CYVS/M/L - DK - F/C/R 80

Page 65: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

63VRV catalogue 2015

Indo

or u

nits

Indoor unit FXFQ20A FXFQ25A FXFQ32A FXFQ40A FXFQ50A FXFQ63A FXFQ80A FXFQ100A FXFQ125ACooling capacity Nom. kW 2.2 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0Heating capacity Nom. kW 2.5 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16.0Power input - 50Hz

Cooling Nom. kW 0.038 0.053 0.061 0.092 0.115 0.186Heating Nom. kW 0.038 0.053 0.061 0.092 0.115 0.186

Dimensions Unit H x W x D mm 204x840x840 246x840x840 288x840x840Weight Unit kg 19 20 21 24 26Decoration panel

Model BYCQ140D7W1Colour Pure White (RAL 9010)Dimensions H x W x D mm 60x950x950Weight kg 5.4

Decoration panel 2

Model BYCQ140D7W1WColour Pure White (RAL 9010)Dimensions H x W x D mm 60x950x950Weight kg 5.4

Decoration panel 3

Model BYCQ140D7GW1Colour Pure White (RAL 9010)Dimensions H x W x D mm 145x950x950Weight kg 10.3

Fan-Air flow rate - 50Hz

Cooling High/Nom./Low m³/min 12.5/10.6/8.8 13.6/11.6/9.5 15.0/12.8/10.5 16.5/13.5/10.5 22.8/17.6/12.4 26.5/19.5/12.4 33.0/26.5/19.9Heating High/Nom./Low m³/min 12.5/10.6/8.8 13.6/11.6/9.5 15.0/12.8/10.5 16.5/13.5/10.5 22.8/17.6/12.4 26.5/19.5/12.4 33.0/26.5/19.9

Sound power level

Cooling High/Nom. dBA 49/- 51/- 53/- 55/- 60/- 61/-

Sound pressure level

Cooling High/Nom./Low dBA 31/29/28 33/31/29 35/33/30 38/34/30 43/37/30 45/41/36Heating High/Nom./Low dBA 31/29/28 33/31/29 35/33/30 38/34/30 43/37/30 45/41/36

Refrigerant Type R-410APiping connections

Liquid/OD/Gas/OD/Drain mm 6.35/12.7/VP25 (O.D. 32 / I.D. 25) 9.52/15.9/VP25 (O.D. 32 / I.D. 25)

Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220Current - 50Hz Maximum fuse amps (MFA) A 16

BYCQ140D7W1 = pure white panel with grey louvers , BYCQ140D7W1W = pure white standard panel with white louvers, BYCQ140D7GW1 = Pure white auto cleaning panelThe BYCQ140D7W1W has white insulations. Be informed that formations of dirt on white insulation is visibly stronger & that it is consequently not advised to install the decoration panel in environments exposed to concentrations of dirt.

See databook for option details.

Daikin’s unique 360° Roundflow cassette, re-engineered for Seasonal Efficiency now includes an optional auto cleaning filter, which automatically cleans itself daily, leading to yearly energy savings of up to 50%.

Features and benefits:

> 360° air discharge ensures uniform air flow and temperature distribution> Modern style decoration panel is available in 3 different variations: pure white

(RAL9010) auto cleaning panel, pure white (RAL9010) standard panel with grey louvers and pure white (RAL9010) standard panel with white louvers

> Higher efficiency and comfort thanks to daily auto cleaning of the filter> Lower maintenance costs thanks to auto cleaning function> Easy dust removal with vacuum cleaner without opening the unit> The presence sensor (optional) adjusts the set point with standard 1°C if no

one is detected in the room, it is possible to adjust the set point with 2, 3 or 4°C (optional). It also automatically directs air flow away from any person to avoid draught

> The floor sensor (optional) detects the average floor temperature and ensures even temperature distribution between ceiling and floor, reducing cold feet problems

> Individual flap control: one flap can be easily closed via the wired remote control (BRC1E52A) in case you refurbish or rearrange your interior

> Low energy consumption thanks to specially developed small tube heat exchanger, DC fan motor and drain pump

> Fresh air intake: up to 20 %> Low installation height: 214mm for class 20-63> Standard drain pump with 850mm lift

* Option not available in combination with BYCQ140D7GW1

FXFQ20-63A

BRC1E52A/B BRC7FA532F

Presence sensor

Floor sensor

FXFQ-A

Roundflow cassette

Page 66: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

64 VRV catalogue 2015

Unique in the market, the fully flat cassette is a remarkable blend

of iconic design and engineering excellence, with an elegant matt

crystal white or a silver and matt crystal white finish.

Fully flat cassettedesigned to be different

Fitting within the ceiling modules and fully flat with the ceiling itself, the cassette is both stylish and unobtrusive.

Superb efficiency and comfort is delivered through the combined use of floor and presence sensors and, when necessary, the individual flap control via the wired remote controller makes it simple to close one or more flaps.

Page 67: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

65VRV catalogue 2015

Indo

or u

nits

Features and benefits:

> Unique design in the market: integrates fully flat into the ceiling and fits flush within an individual ceiling tile

> Remarkable blend of iconic design and engineering excellence with an elegant finish in white or a combination of silver and white

> 15 class unit especially developed for small or well-insulated rooms, such as small offices

> The presence sensor (optional) adjusts the set point with standard 1°C if no one is detected in the room, it is possible to adjust the set point with 2, 3 or 4°C (optional). It also automatically directs air flow away from any person to avoid draught

> The floor sensor (optional) detects the average floor temperature and ensures even temperature distribution between ceiling and floor, reducing cold feet problems

> Individual control: one louvre can be easily closed via the wired remote control (BRC1E52A) in case you would refurbish or rearrange your interior

> Low energy consumption thanks to specially developed small tube heat exchanger, DC fan motor and drain pump

> Fresh air intake for healthy living> Standard drain pump with 850mm lift

FXZQ-A (silver and matt crystal white panel)

FXZQ-A (Matt crystal white panel)

BRC1E52A/B BRC7F530W/S*

Presence sensor

Floor sensor

Indoor unit FXZQ15A FXZQ20A FXZQ25A FXZQ32A FXZQ40A FXZQ50ACooling capacity Nom. kW 1.7 2.2 2.8 3.6 4.5 5.6 Heating capacity Nom. kW 1.9 2.5 3.2 4.0 5.0 6.3 Power input - 50Hz

Cooling Nom. kW 0.043 0.045 0.059 0.092Heating Nom. kW 0.036 0.038 0.053 0.086

Dimensions Unit H x W x D mm 260x575x575Weight Unit kg 15.5 16.5 18.5Decoration panel

Model BYFQ60CWColour White (N9.5)Dimensions H x W x D mm 46x620x620Weight kg 2.8

Decoration panel 2

Model BYFQ60B3Colour White (N9.5) + SilverDimensions H x W x D mm 46x620x620Weight kg 2.8

Decoration panel 3

Model BYFQ60B2Colour White (RAL9010)Dimensions H x W x D mm 55x700x700Weight kg 2.7

Fan-Air flow rate - 50Hz

Cooling High/Nom./Low m³/min 8.5/7/6.5 8.7/7.5/6.5 9/8/6.5 10/8.5/7 11.5/9.5/8 14.5/12.5/10Heating High/Nom./Low m³/min 8.5/7/6.5 8.7/7.5/6.5 9/8/6.5 10/8.5/7 11.5/9.5/8 14.5/12.5/10

Sound powerlevel

Cooling High/Nom. dBA 49/- 50/- 51/- 54/- 60/-

Sound pressure level

Cooling High/Nom./Low dBA 31.5/28/25.5 32/29.5/25.5 33/30/25.5 33.5/30/26 37/32/28 43/40/33Heating High/Nom./Low dBA 31.5/28/25.5 32/29.5/25.5 33/30/25.5 33.5/30/26 37/32/28 43/40/33

Refrigerant Type R-410APiping connections

Liquid/OD/Gas/OD/Drain mm 6.35/12.7/VP20 (I.D. 20/O.D. 26)

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240Current - 50Hz Maximum fuse amps (MFA) A 16

(1) Dimensions include control box

See databook for option details.

FXZQ-A

Fully flat cassette

Page 68: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

66 VRV catalogue 2015

Indoor unit FXCQ20A FXCQ25A FXCQ32A FXCQ40A FXCQ50A FXCQ63A FXCQ80A FXCQ125ACooling capacity Nom. kW 2.2 2.8 3.6 4.5 5.6 7.1 9.0 14.0Heating capacity Nom. kW 2.5 3.2 4.0 5.0 6.3 8.0 10.0 16.0Power input - 50Hz

Cooling Nom. kW 0.031 0.039 0.041 0.059 0.063 0.090 0.149Heating Nom. kW 0.028 0.035 0.037 0.056 0.060 0.086 0.146

Casing Material Galvanised steel plateDimensions Unit H x W x D mm 305x775x620 305x990x620 305x1,445x620Weight Unit kg 19 22 25 33 38Decoration panel

Model BYBCQ40HW1 BYBCQ63HW1 BYBCQ125HW1Colour Fresh white (6.5Y 9.5/0.5)Dimensions H x W x D mm 55x1,070x700 55x1,285x700 55x1,740x700Weight kg 10 11 13

Fan-Air flow rate - 50Hz

Cooling High/Nom./Low m³/min 10.5/9/7.5 11.5/9.5/8 12/10.5/8.5 15/13/10.5 16/14/11.5 26/22.5/18.5 32/27.5/22.5

Sound power level

Cooling Nom. dBA -

Sound pressure level

Cooling High/Nom./Low dBA 32.0/30.0/28.0 34.0/31.0/29.0 34.0/32.0/30.0 36.0/33.0/31.0 37.0/35.0/31.0 39.0/37.0/32.0 42.0/38.0/33.0 46.0/42.0/38.0Heating High/Nom./Low dBA 32.0/30.0/28.0 34.0/31.0/29.0 34.0/32.0/30.0 36.0/33.0/31.0 37.0/35.0/31.0 39.0/37.0/32.0 42.0/38.0/33.0 46.0/42.0/38.0

Refrigerant Type R-410APiping connections

Liquid/OD/Gas/OD/Drain mm 6.35/12.7/VP25 (O.D. 32 / I.D. 25) 9.52/15.9/VP25 (O.D. 32 / I.D. 25)

Air filter Type Resin net with mold resistancePower supply Phase/Frequency/Voltage Hz/V 1~/50/220-240Current - 50Hz Maximum fuse amps (MFA) A 16

See databook for option details.

The 2-way blow ceiling mounted unit has been re-modelled for optimum efficiency and looks. Perfect addition to any portfolio to ensure room airflow is optimised.

Features and benefits:

> Low energy consumption thanks to specially developed small tube heat exchanger, DC fan motor and drain pump

> Stylish unit blends easily with any interior, as the flaps close entirely when not in operation

> Improved comfort thanks to automatic air flow adjustment to required load> Individual control: one louvre can be easily closed via the wired remote control

(BRC1E52A) in case you would refurbish or rearrange your interior> Easy to install: depth of all units is 620mm> Maintenance operations can be performed by removing the front panel> Standard drain pump with 500mm lift

* Cannot control individual louvre control and automatic airflow.

BRC1E52A/B BRC7CA52*

FXCQ20-40A

FXCQ-A

2-way blow ceiling mounted cassette

Page 69: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

67VRV catalogue 2015

Indo

or u

nits

The ceiling mounted corner cassette is an ideal addition to a portfolio meeting specialist location requirements and at the same time maintaining the required visual appearance.

Features and benefits:

> Compact dimensions, can easily be mounted in a narrow ceiling void (only 220mm ceiling space required, 195 with panel spacer, available as accessory)

> Optimum air flow conditions are created by either downward air discharge or frontal air discharge (via optional grille) or a combination of both

> Standard drain pump with 500mm lift

BRC1E52A/B BRC4C61

FXKQ-MA

Indoor unit FXKQ25MA FXKQ32MA FXKQ40MA FXKQ63MACooling capacity Nom. kW 2.8 3.6 4.5 7.10Heating capacity Nom. kW 3.2 4.0 5.0 8.00Power input - 50Hz

Cooling Nom. kW 0.066 0.076 0.105Heating Nom. kW 0.046 0.056 0.085

Dimensions Unit H x W x D mm 215x1,110x710 215x1,310x710Weight Unit kg 31 34Decoration panel

Model BYK45FJW1 BYK71FJW1Colour WhiteDimensions H x W x D mm 70x1,240x800 70x1,440x800Weight kg 8.5 9.5

Fan-Air flow rate - 50Hz

Cooling High/Low m³/min 11/9 13/10 18/15

Sound power level

Cooling Nom. dBA -

Sound pressure level

Cooling High/Low dBA 38.0/33.0 40.0/34.0 42.0/37.0

Refrigerant Type R-410AR-410APiping connections

Liquid/OD/Gas/OD/Drain mm 6.35/12.7/VP25 (O.D. 32 / I.D. 25)

9.52/15.9/VP25 (O.D. 32 / I.D. 25)

Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220Current - 50Hz Maximum fuse amps (MFA) A 15

See databook for option details.

FXKQ-MA

Ceiling mounted corner cassette

Page 70: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

68 VRV catalogue 2015

BRC1E52A/B BRC7G53

FXHQ100A

The ceiling suspended unit has been remodelled with better looks, high efficiency and lower sound levels.

Features and benefits:

> Ideal solution for commercial spaces with solid ceilings> The unit can easily be mounted in corners and narrow spaces, as it only needs

30mm service space at the side> Low energy consumption thanks to DC fan motor and drain pump> Stylish unit blends easily with any interior, as the flaps close entirely when

not in operation> Can be installed in both new and existing buildings> Air flow distribution for ceiling heights up to 3.8m without capacity loss> Wider air discharge thanks to Coanda effect and 100° lateral air distribution

Indoor unit FXHQ32A FXHQ63A FXHQ100ACooling capacity Nom. kW 3.6 7.1 11.2Heating capacity Nom. kW 4.0 8.0 12.5Power input - 50Hz

Cooling Nom. kW 0.107 0.111 0.237Heating Nom. kW 0.107 0.111 0.237

Casing Colour Fresh WhiteDimensions Unit H x W x D mm 235x960x690 235x1,270x690 235x1,590x690Weight Unit kg 24 33 39Fan-Air flow rate - 50Hz

Cooling High/Nom./Low m³/min 14.0/12.0/10.0 20.0/17.0/14.0 29.5/24.0/19.0Heating High/Nom./Low m³/min 14.0/12.0/10.0 20.0/17.0/14.0 29.5/24.0/19.0

Sound power level

Cooling Nom. dBA -

Sound pressure level

Cooling High/Nom./Low dBA 36.0/34.0/31.0 37.0/35.0/34.0 44.0/37.0/34.0Heating High/Nom./Low dBA 36.0/34.0/31.0 37.0/35.0/34.0 44.0/37.0/34.0

Refrigerant Type R-410APiping connections

Liquid/OD/Gas/OD/Drain mm 6.35/12.7/VP20 (I.D. 20/O.D. 26) 9.52/15.9/VP20 (I.D. 20/O.D. 26)

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240Current - 50Hz Maximum fuse amps (MFA) A 16

See databook for option details.

FXHQ-A

Ceiling suspended unit

Page 71: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

69VRV catalogue 2015

Indo

or u

nits

Restyled unit with lower profile, sleeker looks, better efficiency and an integrated junction box.

Features and benefits:

> Ideal solution for commercial spaces with narrow, false or solid ceilings> Separate BEVQ box is no longer needed: the expansion valve is integrated

in the indoor unit> Low energy consumption thanks to DC fan motor and drain pump> Stylish unit blends easily with any interior, as the flaps close entirely when

not in operation> Improved comfort thanks to automatic air flow adjustment to required load> Can be installed in both new and existing buildings> Same outlook for all models (unified dimensions)> Air flow distribution for ceiling heights up to 3.5m without capacity loss> Standard drain pump with 500mm lift> Air can be discharged in 5 different angles between 0 and 60°> Individual flap control: one flap can be easily closed via the wired remote

control (BRC1E52) in case you would refurbish or rearrange your interior

BRC1E52A/B BRC7C58

FXUQ-A

Indoor unit FXUQ71A FXUQ100ACooling capacity Nom. kW 8.0 11.2Heating capacity Nom. kW 9.0 12.5Power input - 50Hz

Cooling Nom. kW 0.090 0.200Heating Nom. kW 0.073 0.179

Casing Colour Fresh WhiteDimensions Unit H x W x D mm 198x950x950Weight Unit kg 26 27Fan-Air flow rate - 50Hz

Cooling High/Nom./Low m³/min 22.5/19.5/16.0 31.0/26.0/21.0Heating High/Nom./Low m³/min 22.5/19.5/16.0 31.0/26.0/21.0

Sound power level

Cooling Nom. dBA -

Sound pressure level

Cooling High/Nom./Low dBA 40.0/38.0/36.0 47.0/44.0/40.0Heating High/Nom./Low dBA 40.0/38.0/36.0 47.0/44.0/40.0

Refrigerant Type R-410APiping connections

Liquid/OD/Gas/OD/Drain mm 9.52/15.9/I.D. 20/O.D. 26

Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220-230Current - 50Hz Maximum fuse amps (MFA) A 16

See databook for option details.

FXUQ-A

4-way blow ceiling suspended unit

Page 72: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

70 VRV catalogue 2015

Perfect for hotel bedrooms where a small concealed ceiling unit is required – flexible and discreet.

Features and benefits:

> Designed for hotel bedrooms> Compact dimensions (230mm high & 652mm deep), can easily be mounted

in a ceiling void> Blends unobtrusively with any interior décor: only the suction and discharge

grilles are visible> The air suction direction can be altered from rear to bottom suction> For easy mounting, the drain pan can be located to the left or right of the unit

BRC1E52A/B BRC4C62

FXDQ-M9

Indoor unit FXDQ20M9 FXDQ25M9Cooling capacity Nom. kW 2.2 2.8Heating capacity Nom. kW 2.5 3.2Power input - 50Hz

Cooling Nom. kW 0.050Heating Nom. kW 0.050

Casing Colour UnpaintedDimensions Unit H x W x D mm 230x502x652Required ceiling void > mm 250Weight Unit kg 17Fan-Air flow rate - 50Hz

Cooling High/Low m³/min 6.7/5.2 7.4/5.8Heating High/Low m³/min 6.7/5.2 7.4/5.8

Sound power level

Cooling Nom. dBA 50

Sound pressure level

Cooling High/Low dBA 37/32Heating High/Low dBA 37/32

Refrigerant Type R-410APiping connections

Liquid/OD/Gas/OD/Drain mm 6.35/12.7/I.D. 21.6, O.D. 27.2

Power supply Phase/Frequency/Voltage Hz/V 1~/50/230Current - 50Hz Maximum fuse amps (MFA) A 16

See databook for option details.

FXDQ-M9

Small concealed ceiling unit

Page 73: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

71VRV catalogue 2015

Indo

or u

nits

The slim concealed unit has a very wide range of capacities to suit an array of applications from hotels to retail to offices.

Features and benefits:

> Compact dimensions, can easily be mounted in a ceiling void of only 240mm> Blends unobtrusively with any interior décor: only the suction and discharge

grilles are visible> 15 class unit especially developed for small or well-insulated rooms,

such as hotel bedrooms and small offices> Low energy consumption thanks to DC inverter fans> Medium external static pressure means unit can be used with flexible ducts

of varying lengths> Standard drain pump with 750mm lift

BRC1E52A/B BRC4C65

FXDQ15-32A

750 mm

Indoor unit FXDQ15A FXDQ20A FXDQ25A FXDQ32A FXDQ40A FXDQ50A FXDQ63ACooling capacity Nom. kW 1.7 2.2 2.8 3.6 4.5 5.6 7.1Heating capacity Nom. kW 1.9 2.5 3.2 4.0 5.0 6.3 8.0Power input - 50Hz

Cooling Nom. kW 0.071 0.078 0.099 0.110Heating Nom. kW 0.068 0.075 0.096 0.107

Casing Colour Galvanised steel / Non paintedDimensions Unit H x W x D mm 200x750x620 200x950x620 200x1,150x620Required ceiling void > mm 240Weight Unit kg 22 26 29Fan-Air flow rate - 50Hz

Cooling High/Nom./Low m³/min 7.5/7.0/6.4 8.0/7.2/6.4 10.5/9.5/8.5 12.5/11.0/10.0 16.5/14.5/13.0

Fan-External static pressure - 50Hz

High/Nom. Pa 30/10 44/15

Sound power level

Cooling Nom. dBA 50 51 52 53 54

Sound pressure level

Cooling High/Nom./Low dBA 32/31/27 33/31/27 34/32/28 35/33/29 36/34/30

Refrigerant Type R-410APiping connections

Liquid/OD/Gas/OD/Drain mm 6.35/12.7/VP20 (I.D. 20/O.D. 26)

9.52/15.9/VP20 (I.D. 20/O.D. 26)

Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220Current - 50Hz Maximum fuse amps (MFA) A 16

See databook for option details.

200m

m

FXDQ-A

Slim concealed ceiling unit

Page 74: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

72 VRV catalogue 2015

FXSQ-A

BRC1E52A/B BRC4C65

See databook for option details.

Optimum comfort guaranteed no matter the length of ductwork or type of grilles.

The FXSQ-A concealed ceiling unit features a 3-step airflow control, which offers improved comfort.

Energy consumption is reduced by 20%, compared with the FXSQ-P series, thanks to the use of a new DC fan. The unit is ideal for shops and offices, because it can be used with ducts of varying lengths.

Features and benefits:

> Automatic airflow adjustment function measures the air volume and static pressure and adjusts it towards the nominal air flow, whatever the length of duct, making installation easier and guaranteeing comfort. Moreover, the ESP can be changed via the wired remote control to optimize the supply air volume

> Slimmest unit in class, only 245mm> Low operating sound level> High external static pressure up to 150Pa facilitates using flexible ducts

of varying lengths> Discretely concealed in the ceiling: only the suction and discharge

grilles are visible> 15 class unit especially developed for small or well-insulated rooms,

such as hotel bedrooms, small offices, etc.> Reduced energy consumption thanks to specially developed DC fan motor> Flexible installation, as the air suction direction can be altered from rear to

bottom suction> Standard built-in drain pump increases flexibility and installation speed

FXSQ-A

Concealed ceiling unit – high static pressure

NEWAVAILABLE

SPRING 2015

Indoor Units FXSQ15A FXSQ20A FXSQ25A FXSQ32A FXSQ40A FXSQ50A FXSQ63A FXSQ80A FXSQ100A FXSQ125A FXSQ140ANominal Cooling kW 1.7 2.2 2.8 3.6 4.5 5.6 7.1 9 11.2 14 16Nominal Heating kW 1.9 2.5 3.2 4 5 6.3 8 10 12.5 16 18Air Flow Rate High m3/sec 0.145 0.15 0.15 0.158 0.25 0.25 0.35 0.38 0.46 0.61 0.65

Low m3/sec 0.1 0.15 0.15 0.15 0.25 0.25 0.35 0.38 0.46 0.61 0.65External Static Pressure

High Pa 150 150 150 150 150 150 150 150 150 150 150Low Pa 30 30 30 30 30 30 30 40 40 50 50

Dimensions H x W x D mm 245 x 550 x 800 245 x 700 x 800 245 x 1000 x 800 245 x 1400 x 800 245 x 1550 x 800

Weight kg 23.5 23.5 23.5 24 28.5 29 35.5 36.5 46 47 51Electrical Details Power Supply Phase 1ph

Hz 50V 230

Running Current W 41 41 41 45 92 95 95 121 157 214 tbcFuse Rating amps 5

Sound Level Sound Pressure

High dBA 29.5 30 30 31 35 35 33 35 36 39 44Low dBA 25 25 25 26 29 29 27 29 31 33 tbc

Sound Power dBA 54 54 54 55 60 60 59 61 61 64 tbcPiping Connections

Liquid inches 1/4 1/4 1/4 1/4 1/4 1/4 3/4 3/4 3/4 3/4 3/4Gas inches 1/2 1/2 1/2 1/2 1/2 1/2 5/8 5/8 5/8 5/8 5/8

Page 75: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

73VRV catalogue 2015

Indo

or u

nits

FXMQ20-32P7

BRC1E52A/B BRC4C65

See databook for option details.

The FXMQ-P7 concealed ceiling unit is a compact unit that can be used for many applications, delivering improved comfort thanks to 3-step airflow control.

Features and benefits:

> Easy installation thanks to automatic air flow adjustment towards nominal air flow rate

> Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible

> Up to 200Pa external static pressure allows extensive ductwork runs and flexible application: ideal for use in large areas

> Low energy consumption thanks to DC inverter fans> Possibility to change ESP via wired remote control allows optimisation of

the supply air volume> The air suction direction can be altered from rear to bottom suction> Standard built-in drain pump increases reliability of the drain system

Reduced installation time> After installation, it is possible that the actual duct resistance is lower than

expected at time of designing. As a consequence the air flow will be too high> With the automatic air flow adjustment function the unit can adapt its fan

speed to a lower curve, so the air flow decreases> The air flow will always be within 10% of the rated air flow because of the

amount of possible fan curves (more than 8 fan curves available per model)> Alternatively the installer can manually select a fan curve with the wired

remote control

FXMQ-P7

Concealed ceiling unit – high static pressure

Indoor Units FXMQ50P7 FXMQ63P7 FXMQ80P7 FXMQ100P7 FXMQ125P7Capacity UK Total Cooling kW 4.50 5.70 7.20 9.00 11.30

UK Sensible Cooling kW 4.10 4.90 6.10 7.30 9.20UK Heating kW 6.30 8.00 10.00 12.50 16.00Nominal Cooling kW 5.60 7.10 9.00 11.20 14.00Nominal Heating kW 6.30 8.00 10.00 12.50 16.00

Air Flow Rate High m3/sec 0.30 0.33 0.42 0.53 0.65Low m3/sec 0.25 0.27 0.33 0.38 0.47

External Static pressure

High Pa 200.0 200.0 200.0 200.0 200.0Low Pa 100.0 100.0 100.0 100.0 100.0

Dimensions H x W x D mm 300 x 1000 x 700 300 x 1400 x 700Weight kg 35 35 35 46 46Electrical Details Power Supply Phase 1ph

Hz 50V 230

Running Current amps 1.4 1.4 1.7 2.3 2.9Fuse Rating amps 5

Sound Level Sound Pressure High dBA 41.0 42.0 43.0 43.0 44.0Low dBA 37.0 38.0 39.0 39.0 40.0

Sound Power dBA 61/- 64/- 67/- 65/- 70/-Piping Connections Liquid inches 1/4 3/8 3/8 3/8 3/8

Gas inches 1/2 5/8 5/8 5/8 5/8

Page 76: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

74 VRV catalogue 2015

The large concealed ceiling unit is perfect for flexible applications for large area’s requiring extensive ductwork runs.

Features and benefits:

> Up to 270Pa external static pressure allows extensive ductwork runs and flexible application: ideal for use in large areas

> Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible

> Up to 31.5kW in heating mode

BRC1E52A/B BRC4C65

FXMQ-MA

Indoor unit FXMQ200MA FXMQ250MACooling capacity Nom. kW 22.4 28.0Heating capacity Nom. kW 25.0 31.5Power input - 50Hz

Cooling Nom. kW 1.294 1.465Heating Nom. kW 1.294 1.465

Dimensions Unit H x W x D mm 470x1,380x1,100Weight Unit kg 137Fan-Air flow rate - 50Hz

Cooling High/Low m³/min 58/50 72/62

Fan-External static pressure - 50Hz

High/Nom. Pa 221/132 270/191

Sound power level

Cooling Nom. dBA -

Sound pressure level

Cooling High/Low dBA 48/45

Refrigerant Type R-410APiping connections

Liquid/OD/Gas/OD/Drain mm 9.52/19.1/PS1B 9.52/22.2/PS1B

Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220Current - 50Hz Maximum fuse amps (MFA) A 15

See databook for option details.

FXMQ-MA

Large concealed ceiling unit

Page 77: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

75VRV catalogue 2015

Indo

or u

nits

Ideal for shops and offices without false ceilings with an extensive range to meet the needs of a variety of different sized facilities. Features and benefits:

> Ideal solution for shops, restaurants or offices with no or narrow false ceilings> Low energy consumption thanks to DC fan motor> Can be installed in both new and existing buildings> Flat, stylish front panel blends easily within any interior décor and is more

easy to clean> 15 class unit especially developed for small or well-insulated rooms,

such as hotel bedrooms and small offices> 5 different discharge angles can be programmed via the remote control> Maintenance operations can be performed from the front of the unit

BRC1E52A/B BRC7E618

FXAQ15-32P

Indoor unit FXAQ15P FXAQ20P FXAQ25P FXAQ32P FXAQ40P FXAQ50P FXAQ63PCooling capacity Nom. kW 1.7 2.2 2.8 3.6 4.5 5.6 7.1Heating capacity Nom. kW 1.9 2.5 3.2 4.0 5.0 6.3 8.0Power input - 50Hz

Cooling Nom. kW 0.017 0.019 0.028 0.030 0.020 0.033 0.050Heating Nom. kW 0.025 0.029 0.034 0.035 0.020 0.039 0.060

Casing Colour White (3.0Y8.5/0.5)White (3.0Y8.5/0.5)Dimensions Unit H x W x D mm 290x795x238 290x1,050x238Weight Unit kg 11 14Fan-Air flow rate - 50Hz

Cooling High/Low m³/min 7.0/4.5 7.5/4.5 8/5 8.5/5.5 12/9 15/12 19/14

Sound power level

Cooling Nom. dBA -

Sound pressure level

Cooling High/Low dBA 34.0/29.0 35.0/29.0 36.0/29.0 37.5/29.0 39.0/34.0 42.0/36.0 47.0/39.0

Refrigerant Type R-410APiping connections

Liquid/OD/Gas/OD/Drain mm 6.35/12.7/VP13 (I.D. 13/O.D. 18)

9.52/15.9/VP13 (I.D. 13/O.D. 18)

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240Current - 50Hz Maximum fuse amps (MFA) A 16

See databook for option details.

FXAQ-P

Wall mounted unit

Page 78: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

76 VRV catalogue 2015

The floor standing unit can be installed quickly and easily in new or existing facilities in a variety of applications.

Features and benefits:

> Stylish modern casing finished in pure white (RAL9010) and iron grey (RAL7011)> Its low height enables the unit to fit perfectly beneath a window> Requires very little installation space> Wired remote control can easily be integrated in the unit using customised slot> Unit can be installed as free standing model by use of optional back plate> Wall mounted installation facilitates cleaning beneath the unit where dust

tends to accumulate

BRC1E52A/B BRC7C62

FXLQ20-25

Indoor unit FXLQ20P FXLQ25P FXLQ32P FXLQ40P FXLQ50P FXLQ63PCooling capacity Nom. kW 2.2 2.8 3.6 4.5 5.6 7.1Heating capacity Nom. kW 2.5 3.2 4.0 5.0 6.3 8.0Power input - 50Hz

Cooling Nom. kW 0.049 0.090 0.110Heating Nom. kW 0.049 0.090 0.110

Casing Colour Fresh white (RAL9010) / Dark grey (RAL7011)Dimensions Unit H x W x D mm 600x1,000x232 600x1,140x232 600x1,420x232Weight Unit kg 27 32 38Fan-Air flow rate - 50Hz

Cooling High/Low m³/min 7/6 8/6 11/8.5 14/11 16/12

Sound power level Cooling Nom. dBA -Sound pressure level

Cooling High/Low dBA 35/32 38/33 39/34 40/35

Refrigerant Type R-410APiping connections

Liquid/OD/Gas/OD/Drain mm 6.35/12.7/O.D. 21 9.52/15.9/O.D. 21

Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220Current - 50Hz Maximum fuse amps (MFA) A 15

See databook for option details.

FXLQ-P

Floor standing unit

Page 79: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

77VRV catalogue 2015

Indo

or u

nits

FXNQ-A

Concealed low wall ducted unit

The concealed low wall units cover a wide range of capacities, and with ductwork connection possible can be installed discreetly with a high degree of flexibility.

The Daikin VRV indoor unit range is one of the widest on the market, offering no less than 26 stylish and elegant models in 116 different variants – all designed to maximise comfort, minimise operating noise and simplify installation and servicing.

Designed to fit rooms of any size and shape, Daikin indoor units are also user friendly, ultra reliable, easy to control and quiet in operation.

All indoors units comply with the Ecodesign legislation by adopting DC fans in all indoor units, improving their energy efficiency.

Features and benefits:

> Ideal for installation in offices, hotels and residential applications> Its low height enables the unit to fit perfectly beneath a window> Blends unobtrusively with any interior décor: only the suction and

discharge grilles are visible> Requires very little installation space as the depth is only 200mm> High ESP allows flexible installation> Also connectable to splits see FBQ-A data sheet BRC1E52A/B BRC4C65

FXNQ-A

NEWAVAILABLE

SUMMER 2015

Indoor Units FXNQ20A FXNQ25A FXNQ32A FXNQ40A FXNQ50A FXNQ63ACapacity Nominal Cooling kW 2.2 2.8 3.6 4.5 5.6 7.1

Nominal Heating kW 2.5 3.2 4 5 6.3 8Air Flow Rate High m3/sec 0.13 0.13 0.13 0.175 0.21 0.275

Low m3/sec 10.6 10.6 10.6 0.14 0.166 0.216Dimensions H x W x D mm 620 x 750 x 200 620 x 950 x 200 620 x 1350 x 200Weight kg 22 22 22 26 26 29Electrical Details Power Supply Phase 1ph

Hz 50V 230

Running Current amps tbc tbc tbc tbc tbc tbcFuse Rating amps 5

Sound Level Sound Pressure High dBA tbc tbc tbc tbc tbc tbcLow dBA tbc tbc tbc tbc tbc tbc

Piping Connections Liquid inches 1/4 1/4 1/4 1/4 1/4 3/8Gas inches 1/2 1/2 1/2 1/2 1/2 5/8

Increased static pressure – up to 44Pa

See databook for option details.

Page 80: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

78 VRV catalogue 2015

Indoor unit HXY080A HXY125ACooling capacity Nom. kW 8 12.5Heating capacity Nom. kW 9 14Casing Colour White

Material Precoated sheet metalDimensions Unit H x W x D mm 890x480x344Weight Unit kg 44Sound pressure level

Nom. dBA -

Operation range Heating Ambient Min.~Max. °C -20~24Water side Min.~Max. °C 25~45

Refrigerant Type R-410ARefrigerant circuit Gas side diameter mm 15.9

Liquid side diameter mm 9.5Water circuit Piping connections diameter inch G 1”1/4 (female)Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240Recommended fuses A 6~16

Producing hot water from a heat pump system provides extremely low cost heating and cooling of water. Temperatures between 5°C to 45°C can be achieved allowing water temperature control for multiple applications without the need for a separate system.

Features and benefits:

> Highly efficient space heating/cooling> Air to water connection to VRV for applications such as underfloor,

AHU, low temperature radiators, ...> Leaving water temperature range from 5°C to 45°C without electric heater> Super wide operating range for cold/hot water production from -20 to +43°C

ambient outdoor temperature> Saves time on system design as all water-side components are fully integrated

with direct control over leaving water temperature> Saves space with contemporary wall hung design> Requires no gas connection or oil tank

HXY-A (low temperature hydrobox)

Liquid pipe

Gas pipe

Hot/cold water

VRV IV heat pump

VRV indoor units

Low temp. radiator

Under floor heating

Air handling unit

See databook for option details.

HXY-A

Hot water generation – VRV IV heat pump systems

Page 81: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

79VRV catalogue 2015

Indo

or u

nits

Producing hot water from a heat recovery VRV system is one of the most energy efficient means of providing hot water within a building. We can provide high and low temperature hot water for bathrooms, toilet wash basins, underfloor heating, radiators and even provide heated water for air handling unit applications.

Using waste heat to provide hot water means you can provide an additional service to your building from the heat recovery VRV system at very low cost

Features and benefits:For both low temperature and high temperature> Uses heat pump technology to produce hot water

efficiently, providing up to 17% savings compared to a gas boiler

> Saves time on system design as all water-side components are fully integrated with direct control over leaving water temperature

> Requires no gas connection or oil tank

For low temperature > Highly efficient space heating/cooling> Leaving water temperature range from 5°C to 45°C

without electric heater> Super wide operating range for cold/hot water

production from -20 to +43°C ambient outdoor temperature

> Saves space with contemporary wall hung design

For high temperature> Possibility to connect thermal solar collectors to

the domestic hot water tank> Leaving water temperature range from 25 to 80°C

without electric heater> Various control possibilities with weather

dependant set point or thermostat control

HXHD-A (High temperature hydrobox)

HXY-A (Low temperature hydrobox)

Indoor unit HXHD125A HXY080A HXY125AHigh Temperature Low Temperature

Cooling Capacity Nom. kW - 8 12.5Heating capacity Nom. kW 14.0 9 14Casing Colour Metallic grey White

Material Precoated sheet metalDimensions Unit H xW xD mm 705x600x695 890x480x344Weight Unit kg 92 44Sound pressure level

Nom. dBA 42 (1) / 43 (2)-

Night quiet mode Level 1 dBA 38 (1)Operation range Heating Ambient Min.~Max. °C -20~20 / 24 (3) -20~24

Water side Min.~Max. °C 25~80 25~45Domestic hot water Ambient Min.~Max. °CDB -20~43 -

Water side Min.~Max. °C 45~75 -Refrigerant Type R-134a R-410ARefrigerant circuit Gas side diameter mm 12.7 15.9

Liquid side diameter mm 9.52 9.5Water circuit Piping connections diameter inch G 1” (female) G 1” 1/4(female)

Heating water system Water volume Min.~Max. l 20~200 -Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 1~/50/220-240Current Recommended fuses A 20 6~16

(1) Sound levels are measured at: EW 55°C; LW 65°C (2) Sound levels are measured at: EW 70°C; LW 80°C (3) Field setting

VRV heat recovery with connection to heating only

hydrobox (REYQ-T)

BS-Box

BS-Box

Heating only hydrobox for VRV

Domestic hot water

Low temp. radiator

Under floor heating

VRV indoor units

Liquid pipe

Discharge gas pipe

Gas pipe

Hot/cold water

Air handling unit

BS-Box

HXY-Alow temperature hydrobox

EKHTSU-AC

EKHWP-B

See databook for option details.

HXHD-A / HXY-A

Hot water generation – VRV IV heat recovery systems

Page 82: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

80 VRV catalogue 2015

Air curtains are the ideal solution to combat the issue of climate

separation across retail outlets or office doorways.

In conjunction with Biddle, Daikin VRV IV heat recovery air curtain solution combines the benefits of the Biddle air curtain technology with the benefits of Daikin VRV IV heat recovery.

Using a combination of rectifier technology, air velocity and temperature control they deliver greater comfort to staff and customers alike, all year round, in all weathers.

Features and benefits:

> Provides virtually free air curtain heating via recovered heat from indoor units in cooling mode

> Connection to the high COP heat recovery system enables COP’s of up to 4.36> Short payback times – less than 3 years> Air curtain rectifier technology – deeply penetrating airstream> Constant air velocity technology – all year round efficiency> European patent> 1.0 to 2.5 metre door widths> Door heights of 2.0 to 3.0 metres> Choice of colour RAL9010:White or RAL9006:Grey

Easy and fast installation of these systems not only reduces costs but makes expensive water systems, boilers and gas connections redundant. Integrating a Biddle air curtain with Daikin VRV also eliminates the need to install multiple outdoor units thereby reducing installation time and costs further. This combination enables Daikin to offer its customers the ultimate climate control solution comprising cooling, heating, outdoor-indoor climate separation and fresh air ventilation.

Air curtainsfor commercial applications

Page 83: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

81VRV catalogue 2015

Indo

or u

nits

CYVS/M/L - DK - F/C/R

Air curtains for commercial applications

Some air curtains may be ECA compliant please see ECA website for details www.daikin.co.uk/ECA

See databook for option details.

Maximum Door Width 1.0 1.5 2.0 2.5Mounting Height *2 3.2 / 2.3Model name CYVM100DK80*BC CYVM150DK80*BC CYVM200DK100*BC CYVM250DK140*BCType * = F * = C * = R * = F * = C * = R * = F * = C * = R * = F * = C * = RHeating capacity speed 3 kW 9.20 11.00 13.40 19.90Delta T Inlet = room temperature speed 3 kW 17 14 13 15Power input (50Hz) Fan only / Heating kW 0.37/0.37 0.56/0.56 0.75/0.75 0.94/0.94Dimensions Height mm 270 270 270 270 270 270 270 270 270 270 270 270

Width mm 1,000 1,000 1,048 1,500 1,500 1,548 2,000 2,000 2,048 2,500 2,500 2,548Depth mm 590 891 561 590 821 561 590 821 561 590 821 561

Weight kg 57 68 66 73 88 93 94 111 117 108 136 144Casing Colour white RAL9010 white RAL9010 white RAL9010 white RAL9010Minimum requiring ceiling void mm 420 420 420 420Fan - Air flow rate Heating speed 3 m3/sec 0.446 0.669 0.892 1.115Sound pressure Heating speed 3 dBA 50 51 53 54Refrigerant Type R-410A R-410A R-410A R-410APiping connections Liquid (OD) / Gas mm 9.52/16.0 9.52/16.0 9.52/16.0 9.52/19.0Power supply ph/V/Hz 1~/230/50 1~/230/50 1~/230/50 1~/230/50

Maximum Door Width 1.0 1.5 2.0 2.5Mounting Height *2 3.7 / 2.5Model name CYVM100DK80*BC CYVM150DK80*BC CYVM200DK100*BC CYVM250DK140*BCType * = F * = C * = R * = F * = C * = R * = F * = C * = R * = F * = C * = RHeating capacity speed 3 kW 9.20 11.00 13.40 19.90Delta T Inlet = room temperature speed 3 kW 17 14 13 15Power input (50Hz) Fan only / Heating kW 0.37/0.37 0.56/0.56 0.75/0.75 0.94/0.94Dimensions Height mm 270 270 270 270 270 270 270 270 270 270 270 270

Width mm 1,000 1,000 1,048 1,500 1,500 1,548 2,000 2,000 2,048 2,500 2,500 2,548Depth mm 590 891 561 590 821 561 590 821 561 590 821 561

Weight kg 57 68 66 73 88 93 94 111 117 108 136 144Casing Colour white RAL9010 white RAL9010 white RAL9010 white RAL9010Minimum requiring ceiling void mm 420 420 420 420Fan - Air flow rate Heating speed 3 m3/sec 0.446 0.669 0.892 1.115Sound pressure Heating speed 3 dBA 50 51 53 54Refrigerant Type R-410A R-410A R-410A R-410APiping connections Liquid (OD) / Gas mm 9.52/16.0 9.52/16.0 9.52/16.0 9.52/19.0Power supply ph/V/Hz 1~/230/50 1~/230/50 1~/230/50 1~/230/50

Small air curtains:

Medium air curtains:

Large air curtains:

Maximum Door Width 1.0 1.5 2.0 2.5Mounting Height *2 2.7 / 2.0Model name CYVS100DK80*BC CYVS150DK80*BC CYVS200DK100*BC CYVS250DK140*BCType * = F * = C * = R * = F * = C * = R * = F * = C * = R * = F * = C * = RHeating capacity speed 3 kW 7.40 9.00 11.60 16.20Delta T Inlet = room temperature speed 3 kW 15 15 15 16Power input (50Hz) Fan only / Heating kW 0.23/0.23 0.35/0.35 0.46/0.46 0.58/0.58Dimensions Height mm 270 270 270 270 270 270 270 270 270 270 270 270

Width mm 1,000 1,000 1,048 1,500 1,500 1,548 2,000 2,000 2,048 2,500 2,500 2,548Depth mm 590 891 561 590 821 561 590 821 561 590 821 561

Weight kg 56 59 61 66 83 88 83 102 108 107 129 137Casing Colour white RAL9010 white RAL9010 white RAL9010 white RAL9010Minimum requiring ceiling void mm 420 420 420 420Fan - Air flow rate Heating speed 3 m3/sec 0.323 0.485 0.647 0.808Sound pressure Heating speed 3 dBA 47 49 50 51Refrigerant Type R-410A R-410A R-410A R-410APiping connections Liquid (OD) / Gas mm 9.52/16.0 9.52/16.0 9.52/16.0 9.52/19.0Power supply ph/V/Hz 1~/230/50 1~/230/50 1~/230/50 1~/230/50

F = Free hanging model C = Cassette model R = Recessed model

Page 84: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

82 VRV catalogue 2015

Integrated ventilation

Heat reclaim ventilation

Heat Reclaim Ventilation (HRV) – VAM-FA/FB 83

Heat Reclaim Ventilation, humidification and air processing – VKM-GM / VKM-GB 84

Outdoor air processing – FXMQ-MF 86

VRV air handling applications – EKEXV / EKEQ 87

Heat reclaim ventilation

Proper ventilation is a key component of climate control in buildings, offices and shops.

At a basic level, it ensures a flow of incoming fresh air and outgoing stale air. However, Daikin’s Heat Reclaim Ventilation (HRV) solution can do so much more.

HRV can recover heat and optimise the balance between the indoor and outdoor temperature and humidity, thus reducing the load on the system and increasing efficiency.

VRV air handling applications

For medium and large commercial spaces, Daikin offers a range of R-410A inverter condensing units that connect to air handling units. This approach combines the flexibility of our VRV units with air handling applications, resulting in a simple, reliable solution.

Daikin offers a variety of solutions for the provision of fresh air ventilation

to offices, hotels, stores and other commercial outlets: each one

complementary to – and as flexible as – the VRV system itself.

VRV air handling applications

Page 85: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

83VRV catalogue 2015

Vent

ilatio

n

Total heat exchanged

foul air

Clean outdoor air

Total heat exchanged

clean airFoul indoor air

Ventilation VAM150FA VAM250FA VAM350FB VAM500FB VAM650FB VAM800FB VAM1000FB VAM1500FB VAM2000FBPower input - 50Hz

Heat exchange mode

Nom. Ultra high kW 0.116 0.141 0.132 0.178 0.196 0.373 0.375 0.828 0.852

Bypass mode Nom. Ultra high kW 0.116 0.141 0.132 0.178 0.196 0.373 0.375 0.828 0.852Temperature exchange efficiency - 50Hz

Ultra high % 74 72 75 74 75

Enthalpy exchange efficiency - 50Hz

Cooling Ultra high % 58 61 58 60 61Heating Ultra high % 64 65 62 63 65 66

Operation mode Heat exchange mode / Bypass mode / Fresh-up modeHeat exchange system Air to air cross flow total heat (sensible + latent heat) exchangeHeat exchange element Specially processed non-flammable paperDimensions Unit H x W x D mm 285x776x525 301x828x816 364x1,004x868 364x1,004x1,156 726x1,512x868 726x1,512x1,156Weight Unit kg 24 33 52 55 64 131 152Fan-Air flow rate - 50Hz

Heat exchange mode

Ultra high m³/h 150 250 350 500 650 800 1,000 1,500 2,000

Bypass mode Ultra high m³/h 150 250 350 500 650 800 1,000 1,500 2,000Fan-External static pressure - 50Hz

Ultra high Pa 69 64 98 93 137 157 137

Sound pressure level - 50Hz

Heat exchange mode

Ultra high dBA 27 / 28.5 28 / 29 32 33 34.5 36 39.5 40

Bypass mode Ultra high dBA 27 / 28.5 28 / 29 32 33.5 34.5 36 40.5 40Operation range Min. °CDB -15

Max. °CDB 50Relative humidity % 80% or less

Connection duct diameter mm 100 150 200 250 350Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220Current Maximum fuse amps (MFA) A 15 16

Heat recovery ventilation

The VAM-FA/FB system modulates the temperature and humidity of incoming fresh air to match the indoor conditions. This provides a balance between the indoor and outdoor temperatures, significantly reducing the cooling or heating load on the air conditioning system.

Features and benefits:

> HRV units can be controlled individually or integrated with a Daikin VRV or Sky Air system

> Energy saving ventilation via recovery of indoor unit heat or cold> Ideal solution for shops, restaurants or offices requiring maximum floor space

for furniture, decorations and fittings> Free cooling when outdoor temperature is below the indoor temperature

(e.g. during the night)> Low energy consumption thanks to DC inverter fans> Prevents energy losses from over-ventilation while maintaining indoor air

quality with CO2 sensor (optional)

> Can be used as a stand-alone unit or integrated in the VRV system> Wide range of units: air flow rate from 150 up to 2,000 m3/h> High efficiency filters available in F6 ,F7 and F8 grades> Specially developed heat exchange element with

High Efficiency Paper (HEP)> No drain piping needed> Can operate in over- and under-pressure

conditions

VAM-FA/FB

Daikin Heat Reclaim Ventilation (HRV)

Page 86: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

84 VRV catalogue 2015

Exhaust Fan Heat Exchanger Elements

Damper Motor

DamperEA(Exhaust air to outdours)

OA(Fresh air from outdoors)

Air Supply Fan

Electronics Box (Control box)

SA (Supply air to room)

RA(Return air from room)

Float switch Solenoid valve

waterSA

Drain pan Drain

AIRFLOW

Humidifier element:Utilising the principle of capillary action, water is permeated throughout the humidifier element. The heated air from the DX coil passes through the humidifier and absorbs the moisture.

1 VKM-GM example

Operation example: humidification & air processing (heating mode)1

DX coil(Direct expansion coil)

> Energy saving ventilation using indoor heating, cooling and moisture recovery> Creates a high quality indoor environment by pre conditioning incoming

fresh air> Humidification of the incoming air results in comfortable indoor humidity level,

even during heating> Ideal solution for shops, restaurants or offices requiring maximum floor space

for furniture, decorations and fittings> Free cooling possible when outdoor temperature is below indoor temperature

(eg. during nighttime)> Low energy consumption thanks to DC fan motor> Prevents energy losses from over-ventilation while maintaining indoor air

quality with optional CO2 sensor

> Shorter installation time thanks to easy adjustment of nominal air flow rate, so less need for dampers compared with traditional installation.

> Specially developed heat exchange element with High Efficiency Paper (HEP)> Can operate in over- and under pressure

VKM-GM / VKM-GB

Heat Reclaim Ventilation, humidification and air processing

Page 87: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

85VRV catalogue 2015

Vent

ilatio

n

Heat reclaim ventilation, air processing and humidication

Heat reclaim ventilation and air processing

Ventilation VKM50GBM VKM80GBM VKM100GBM VKM50GB VKM80GB VKM100GBPower input - 50Hz

Heat exchange mode

Nom. Ultra high kW 0.270 0.330 0.410 0.270 0.330 0.410

Bypass mode Nom. Ultra high kW 0.270 0.330 0.410 0.270 0.330 0.410Fresh air conditioning load

Cooling kW 4.71 / 1.91 / 3.5 7.46 / 2.96 / 5.6 9.12 / 3.52 / 7.0 4.71 / 1.91 / 3.5 7.46 / 2.96 / 5.6 9.12 / 3.52 / 7.0Heating kW 5.58 / 2.38 / 3.5 8.79 / 3.79 / 5.6 10.69 / 4.39 / 7.0 5.58 / 2.38 / 3.5 8.79 / 3.79 / 5.6 10.69 / 4.39 / 7.0

Temperature exchange efficiency - 50Hz

Ultra high/High/Low % 76/76/77.5 78/78/79 74/74/76.5 76/76/77.5 78/78/79 74/74/76.5

Enthalpy exchange efficiency - 50Hz

Cooling Ultra high/High/Low % 64/64/67 66/66/68 62/62/66 64/64/67 66/66/68 62/62/66Heating Ultra high/High/Low % 67/67/69 71/71/73 65/65/69 67/67/69 71/71/73 65/65/69

Operation mode Heat exchange mode / Bypass mode / Fresh-up modeHeat exchange system Air to air cross flow total heat (sensible + latent heat) exchangeHeat exchange element Specially processed non-flammable paperHumidifier System Natural evaporating type -Casing Material Galvanised steel plateDimensions Unit H x W x D mm 387x1,764x832 387x1,764x1,214 387x1,764x832 387x1,764x1,214Weight Unit kg 100 119 123 94 110 112Fan-Air flow rate - 50Hz

Heat exchange mode

Ultra high m³/h 500 750 950 500 750 950

Bypass mode Ultra high m³/h 500 750 950 500 750 950Fan-External static pressure - 50Hz

Ultra high Pa 200 205 110 210 150

Sound pressure level - 50Hz

Heat exchange mode

Ultra high dBA 38 40 39 41.5 41

Bypass mode Ultra high dBA 39 41 40 41.5 41Operation range Around unit °CDB 0°C~40°CDB, 80% RH or less

Supply air °CDB -15°C~40°CDB, 80% RH or lessReturn air °CDB 0°C~40°CDB, 80% RH or lessOn coil temperature

Cooling Max. °CDB -15Heating Min. °CDB 43

Refrigerant Type R-410AConnection duct diameter mm 200 250 200 250Piping connections

Liquid OD mm 6.35Gas OD mm 12.7Water supply mm 6.4 -Drain PT3/4 external thread

Air filter Type Multidirectional fibrous fleecesPower supply Phase/Frequency/Voltage Hz/V 1~/50/220-240Current Maximum fuse amps (MFA) A 15

Heat recovery ventilation, humidification & air processing

VKM-GM example:

Page 88: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

86 VRV catalogue 2015

Ventilation & air processing

(1) Not connectable to VRV III-S (RXYSQ-P8V1, RXYSQ-PBY1)

Ventilation & air processing FXMQ125MF FXMQ200MF FXMQ250MFCooling capacity Nom. kW 14.0 22.4 28.0Heating capacity Nom. kW 8.9 13.9 17.4Power Input (50Hz)

Cooling Nominal kW 0.359 0.548 0.638Heating Nominal kW 0.359 0.548 0.638

Dimensions Unit H x W x D mm 470x744x1,100 470x1,380x1,100Weight Unit kg 86 123Air Flow Rate Cooling m3/min 18 28 35

Heating m3/min -External Static Pressure

Standard Pa 185 225 205

Refrigerant Type R-410ASound Power Cooling Nominal dBA -Sound Pressure Cooling Nominal (220V) dBA 42 47Operation range On coil

temperatureCooling max. °CDB 43Heating min. °CDB -5

Piping connections

Liquid OD mm 9.52Gas OD mm 15.9 19.1 22.2Drain PS1B

Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

The FXMQ-MF is an outdoor air processing unit with integrated ventilation and air processing, combining fresh air treatment and air conditioning via a single system.

Features and benefits:

Both fresh air treatment and air conditioning can be provided via a single system using heat pump technology without the usual design problems associated with balancing air supply and discharge.

Air conditioning indoor units and an outdoor air treatment unit can be connected to the same refrigerant line, resulting in enhanced design flexibility and a significant reduction in total system costs.

> 100% fresh air intake possible> Leaves maximum floor and wall space for furniture, decorations and fittings> Operation range: -5°C to 43°C> 225 Pa external static pressure allows extensive ductwork runs and flexible

application: ideal for use in large areas> Drain pump kit available as an accessory

FXMQ-MF

Outdoor air processing

Page 89: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

87VRV catalogue 2015

Vent

ilatio

n

A range of R-410A inverter condensing units for multi applications with air handling requirements.

Features and benefits:

> Inverter controlled units> Large capacity range (from 5 to 54HP) heat recovery,

heat pump R-410A> Control of room temperature via Daikin control> Large range of expansion valve kits available> BRC1E52A/B is used to set the set point temperature

(connected to the EKEQMCBA)> Connectable to all VRV heat recovery and heat

pump systems

gas pipe

liquid pipe

F1-F2

other communication

EKEXV-kit

EKEQMCB

EKEXV – Expansion valve kit for air handling application

> The system provides optimised air conditions such as fresh air and humidity control and can be used in small warehouses, showrooms and offices

> Wide range of units offers maximum application potential and flexible control options

> Air handling unit, control box and expansion valve kit are required for each combination

> Both option kits are designed for indoor and outdoor installation and can be wall mounted

Ventilation EKEXV50 EKEXV63 EKEXV80 EKEXV100 EKEXV125 EKEXV140 EKEXV200 EKEXV250 EKEXV400 EKEXV500Dimensions Unit H x W x D mm 401x215x78Weight Unit kg 2.9Sound pressure level Nom. dBA 45

Operation RangeHeating Min. °CDB 10Cooling Max. °CDB 35Refrigerant Type R-410APiping connections Liquid OD mm 6.35 9.52 12.7 15.9

Gas OD mm 6.35 9.52

EKEQ – Control box for air handling applications

EKEQDCB EKEQFCBA EKEQMVBAApplication Pair MultiOutdoor unit ERQ VRVDimensions Unit H x W x D mm 132x400x200

Packed unit H x W x D mm 215x495x310Weight Unit kg 3.6 3.9 3.6

Packed unit kg 4.6 4.9 4.6Packing Material Carton / EPS / PlasticCasing Colour White grey

Material Resin

Wide range of control possibilities: > control w: full external control from 3rd party temperature

controller with volt free remote enable contact and linear variable capacity control output (3rd party DDC Controller required).

> control y: control by fixed evaporating temperature;> control z: room or suction temperature control via Daikin remote control> remote ON/OFF can be achieved by an optional adapter KRP4A51

EKEXV / EKEQ

VRV air handling applications

EKEXV class Cooling HeatingAllowed heat exchanger capacity [kW] Allowed heat exchanger capacity [kW]

minimum maximum minimum maximum50 5 6.2 5.6 763 6.3 7.8 7.1 8.880 7.9 9.9 8.9 11.1

100 10 12.3 11.2 13.8125 12.4 15.4 13.9 17.3140 15.5 17.6 17.4 19.8200 17.7 24.6 19.9 27.7250 24.7 30.8 27.8 34.7400 35.4 49.5 39.8 55500 49.6 61.6 55.1 69.3

Saturated evaporating temperature: 6°C. Air temperature: 27°C DB / 19°C WB Saturated evaporating temperature: 46°C. Air temperature: 20°C DB

Page 90: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

88 VRV catalogue 2015

Type Model Product name 4 5 6 8 10 12 13 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54

Air

cool

ed

VRV

IV h

eat r

ecov

ery

- Best efficiency & comfort solution - Fully integrated solution with heat recovery for maximum efficiency with COPs of up to 8 ! - Covers all thermal needs of a building via a single point of contact: accurate temperature control, ventilation, hot water, air handling units and Biddle air curtains - “Free” heating and hot water through heat recovery - The perfect personal comfort for guests/tenants via simultaneous cooling & heating - Incorporates VRV IV standards & technologies such as Variable Refrigerant temperature and continuous heating - Allows technical cooling - Widest range of BS boxes on the market

REYQ-T

VRV

IV h

eat p

ump

w

ith

cont

inuo

us

heat

ing

- Daikin’s optimum solution with top comfort - Covers all thermal needs of a building via a single point of contact: accurate temperature control, ventilation, hot water, air handling units and Biddle air curtains - Connectable to stylish indoor units (Daikin Emura, Nexura) - Incorporates VRV IV standards & technologies such as Variable Refrigerant temperature and continuous heating

RYYQ-T

VRVI

II-S - Space saving solution without compromising on efficiency

- For residential and light commercial applications - Space saving design - Either connect VRV of stylish indoor units (Daikin Emura, Nexura)

RXYSQ- P8V1/P8Y1

VRVI

V-S

se

ries

- Space saving solution without compromising on efficiency - Space saving trunk design for flexible installation - Covers all thermal needs of a building via a single point of contact: accurate temperature control, ventilation, air handling units and Biddle air curtains - Either connect VRV of stylish indoor units (Daikin Emura, Nexura) - Incorporates VRV IV standards & technologies such as Variable Refrigerant temperature

VRVI

V-S

se

ries

com

pac

t - The most compact VRV - Compact and lightweight single fan design saves space and is easy to install - Covers all thermal needs of a building via a single point of contact: accurate temperature control, ventilation, air handling units and Biddle air curtains - Either connect VRV of stylish indoor units (Daikin Emura, Nexura) - Incorporates VRV IV standards & technologies such as Variable Refrigerant temperature

Repl

acem

ent V

RV

heat

reco

very - Quick & quality replacement for R-22 and R-407C systems

- Cost-effective and fast replacement through re-use of existing piping - Up to 40% more efficient than R-22 systems - No interruption of daily business while replacing your system - Replace Daikin and other manufacturers systems safely

RQCEQ-P3

Repl

acem

ent V

RV

heat

pum

p

- Quick & quality replacement for R-22 and R-407C systems - Cost-effective and fast replacement through re-use of existing piping - Up to 80% more efficient than R-22 systems - No interruption of daily business while replacing your system - Replace Daikin and other manufacturers systems safely - Incorporates VRV IV standards & technologies such as Variable Refrigerant temperature

RXYQQ-T

Wat

er c

oole

d

Wat

er c

oole

d VR

V IV

- Ideal for high rise buildings, using water as heat source - Reduced CO2 emissions thanks to the use of geothermal energy as a renewable energy source - No need for an external heating or cooling source when used in geothermal mode - Covers all thermal needs of a building via a single point of contact: accurate temperature control, ventilation, hot water, air handling units and Biddle air curtains - Compact & lightweight design can be stacked for maximum space saving - Incorporates VRV IV standards & technologies such as Variable Refrigerant temperature - Variable Water Flow control option increases flexibility and control

RWEYQ-T8

Products overview

Outdoor units

Single unit

Multi combination

NEWAVAILABLE LATE 2015

NEWAVAILABLE

MID 2015

Page 91: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

89VRV catalogue 2015

Port

folio

Type Model Product name 4 5 6 8 10 12 13 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54

Air

cool

ed

VRV

IV h

eat r

ecov

ery

- Best efficiency & comfort solution - Fully integrated solution with heat recovery for maximum efficiency with COPs of up to 8 ! - Covers all thermal needs of a building via a single point of contact: accurate temperature control, ventilation, hot water, air handling units and Biddle air curtains - “Free” heating and hot water through heat recovery - The perfect personal comfort for guests/tenants via simultaneous cooling & heating - Incorporates VRV IV standards & technologies such as Variable Refrigerant temperature and continuous heating - Allows technical cooling - Widest range of BS boxes on the market

REYQ-T

VRV

IV h

eat p

ump

w

ith

cont

inuo

us

heat

ing

- Daikin’s optimum solution with top comfort - Covers all thermal needs of a building via a single point of contact: accurate temperature control, ventilation, hot water, air handling units and Biddle air curtains - Connectable to stylish indoor units (Daikin Emura, Nexura) - Incorporates VRV IV standards & technologies such as Variable Refrigerant temperature and continuous heating

RYYQ-T

VRVI

II-S - Space saving solution without compromising on efficiency

- For residential and light commercial applications - Space saving design - Either connect VRV of stylish indoor units (Daikin Emura, Nexura)

RXYSQ- P8V1/P8Y1

VRVI

V-S

se

ries

- Space saving solution without compromising on efficiency - Space saving trunk design for flexible installation - Covers all thermal needs of a building via a single point of contact: accurate temperature control, ventilation, air handling units and Biddle air curtains - Either connect VRV of stylish indoor units (Daikin Emura, Nexura) - Incorporates VRV IV standards & technologies such as Variable Refrigerant temperature

VRVI

V-S

se

ries

com

pac

t - The most compact VRV - Compact and lightweight single fan design saves space and is easy to install - Covers all thermal needs of a building via a single point of contact: accurate temperature control, ventilation, air handling units and Biddle air curtains - Either connect VRV of stylish indoor units (Daikin Emura, Nexura) - Incorporates VRV IV standards & technologies such as Variable Refrigerant temperature

Repl

acem

ent V

RV

heat

reco

very - Quick & quality replacement for R-22 and R-407C systems

- Cost-effective and fast replacement through re-use of existing piping - Up to 40% more efficient than R-22 systems - No interruption of daily business while replacing your system - Replace Daikin and other manufacturers systems safely

RQCEQ-P3

Repl

acem

ent V

RV

heat

pum

p

- Quick & quality replacement for R-22 and R-407C systems - Cost-effective and fast replacement through re-use of existing piping - Up to 80% more efficient than R-22 systems - No interruption of daily business while replacing your system - Replace Daikin and other manufacturers systems safely - Incorporates VRV IV standards & technologies such as Variable Refrigerant temperature

RXYQQ-T

Wat

er c

oole

d

Wat

er c

oole

d VR

V IV

- Ideal for high rise buildings, using water as heat source - Reduced CO2 emissions thanks to the use of geothermal energy as a renewable energy source - No need for an external heating or cooling source when used in geothermal mode - Covers all thermal needs of a building via a single point of contact: accurate temperature control, ventilation, hot water, air handling units and Biddle air curtains - Compact & lightweight design can be stacked for maximum space saving - Incorporates VRV IV standards & technologies such as Variable Refrigerant temperature - Variable Water Flow control option increases flexibility and control

RWEYQ-T8

Capacity (HP)

Description / Combination

VRV

indo

or u

nits

Resi

dent

ial i

ndoo

r uni

ts

LT H

ydro

box

HX

Y-A

HT

Hyd

rob

ox H

XHD

-A

HRV

uni

ts V

AM

-, VK

M-

AH

U c

onne

ctio

n EK

EXV-

+ E

KEQ

MCB

AH

U c

onne

ctio

n EK

EXV-

+ E

KEQ

FCB

Air

cur

tain

s C

YV-D

K-

Remarks

VRV IV Heat Recovery REYQ-T � O � � � � O � Standard total system connection ratio limit: 50 ~ 130%

with only VRV indoor units

with LT/HT Hydroboxes • Max 32 indoor units, even on 16HP and larger systems• Total system connection ratio up to 200% possible

HRV units VAM-, VKM-

• Dedicated systems (with only ventilation units) not allowed - a mix with standard VRV indoor units is allways neccessaryAHU connection EKEXV + EKEQMCB

Biddle air curtain CYV-DK-

VRV IV Heat Pump RYYQ-T � � � O � � � � Standard total system connection ratio limit: 50 ~ 130%

with only VRV indoor units • 200% total system connection ratio possible under special circumstances

with residential indoor units • Only single-module systems (RYYQ 8~20 T / RXYQ 8~20 T)• Max 32 indoor units, even on 16HP, 18HP and 20HP systems

with LT Hydroboxes • Max 32 indoor units, even on 16HP and larger systems• Contact Daikin in case of multi-module systems (>20HP)

VRV III-S Mini VRV RXYSQ-P8 � � O O � � O � Standard total system connection ratio limit: 50 ~ 130%

with VRV indoor units

with Split indoor units • Total system connection ratio in terms of VRV indexes: 56 ~ 145%

VRV IV-S Mini VRV � � O O � � O � Standard total system connection ratio limit: 50 ~ 130%

with VRV indoor units

with Split indoor units • Total system connection ratio in terms of VRV indexes: 56 ~ 145%

VRV IV-S Mini VRV � � O O � � O � Standard total system connection ratio limit: 50 ~ 130%

with VRV indoor units

with Split indoor units • Total system connection ratio in terms of VRV indexes: 56 ~ 145%

VRV III-Q Replacement H/R RQCEQ-P O O O O O O Standard total system connection

ratio limit: 50 ~ 130%

VRV IV-Q Replacement H/P RXYQQ-T O O O O Standard total system connection

ratio limit: 50 ~ 130%

VRV IV-W Water-cooled VRV RWEYQ-T O O O O Standard total system connection

ratio limit: 50 ~ 130%

� ... connection of indoor unit possible, but not necessarily simultaneously with other allowed indoor units ... connection of indoor unit possible even simultaneously with other checked units in the same row

O ... connection of indoor not possible on this outdoor unit system

Page 92: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

90 VRV catalogue 2015

Type Model Product name 15 20 25 32 40 50 63 71 80 100 125 140 200 250

Ceiling mounted cassette

Round flow cassette

- 360° air discharge for optimum efficiency and comfort - Auto cleaning function ensures high efficiency - Intelligent sensors save energy and maximize comfort - Flexibility to suit every room layout - Lowest installation height in the market!

FXFQ-A

Fully flat cassette - Unique design in the market that integrates fully flat into the ceiling - Perfect integration in standard architectural ceiling tiles - Blend of iconic design and engineering excellence with a white or silver and white finish - Intelligent sensors save energy and maximize comfort - Small capacity unit developed for small or well-insulated rooms - Flexibility to suit every room layout

FXZQ-A

2-way blow ceiling mounted cassette

- Thin, lightweight design installs easily in narrow ceiling spaces - Depth of all units is 620mm, ideal for narrow ceiling spaces - Flexibility to suit every room layout - Reduced energy consumption thanks to DC fan motor - Stylish unit blends easily with any interior. The flaps close entirely when the unit is not operating - Optimum comfort guaranteed with automatic air flow adjustment to the required load

FXCQ-A

Ceiling mounted corner cassette

- 1-way blow unit for corner installation - Compact dimensions enable installation in narrow ceiling voids - Flexible installation thanks to different air discharge options

FXKQ-MA

Concealed ceiling

Small concealed ceiling unit

- Designed for hotel rooms - Compact dimensions enable installation in narrow ceiling voids - Discretely concealed in the ceiling: only the grilles are visible - Flexible installation as the air suction direction can be altered from rear to bottom suction

FXDQ-M9 Slim concealed ceiling unit

- Slim design for flexible installation - Compact dimensions enable installation in narrow ceiling voids - Medium external static pressure up to 44Pa - Only grilles are visible - Small capacity unit developed for small of well-insulated rooms - Reduced energy consumption thanks to DC fan motor

FXDQ-A

Concealed ceiling unit with high ESP

- Optimum comfort guaranteed no matter the length of ductwork or type of grilles - Automatic air flow adjustment function measures the air volume and static pressure and adjusts it towards the nominal air flow, guaranteeing comfort - High external static pressure up to 150Pa - Only grilles are visible - Reduced energy consumption thanks to DC fan motor - Flexible installation as the air suction direction can be altered from rear to bottom suction - Only 245mm high in the ceiling

FXSQ-A

Concealed ceiling unit with high ESP

- ESP up to 200, ideal for large sized spaces - Optimum comfort guaranteed no matter the length of ductwork or type of grilles, thanks to automatic air flow adjustment - Only grilles are visible - Reduced energy consumption thanks to DC fan motor - Flexible installation as the air suction direction can be altered from rear to bottom suction

FXMQ-P7

Concealed ceiling unit with high ESP

- ESP up to 270, ideal for extra large sized spaces - Only grilles are visible - Large capacity unit: up to 31.5 kW heating capacity

FXMQ-MA

Wall mounted

Wall mounted unit - For rooms with no false ceilings nor free floor space - Flat, stylish front panel blends easily with any interior décor and is more easy to clean - Can easily be installed in both new and refurbishment projects - Small capacity unit developed for small of well-insulated rooms - Reduced energy consumption thanks to DC fan motor - The air is comfortably spread up- and downwards thanks to 5 different discharge angles

FXAQ-P

Ceiling suspended

Ceiling suspended unit

- For wide rooms with no false ceilings nor free floor space - Ideal for comfortable air flow in wide rooms thanks to Coanda effect - Even rooms with ceilings up to 3.8m can be heated up or cooled down very easily! - Can easily be installed in both new and refurbishment projects - Can even be mounted in corners or narrow spaces without any problem - Reduced energy consumption thanks to DC fan motor

FXHQ-A

4-way blow ceiling suspended unit

- Unique Daikin unit for high rooms with no false ceilings nor free floor space - Even rooms with ceilings up to 3.5m can be heated up or cooled down very easily! - Can easily be installed in both new and refurbishment projects - Flexibility to suit every room layout - Reduced energy consumption thanks to DC fan motor

FXUQ-A

Floor standing

Floor standing unit - For perimeter zone air conditioning - Can be installed in front of glass walls or free standing as both the front and the back are finished - Ideal for installation beneath a window - Stylish unit blends easily with any interior - Requires very little installation space - Wall mounted installation facilitates cleaning beneath the unit

FXLQ-P

Concealed floor standing unit

- Ideal for installation in offices, hotels and residential applications - Discretely concealed in the wall, leaving only the suction and discharge grilles visible - Can even be installed underneath a window - Requires very little installation space as the depth is only 200mm - High ESP allows flexible installation

FXNQ-A

Cooling capacity (kW)1 1.7 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2 14.0 16.0 22.4 28.0

Heating capacity (kW)2 1.9 2.5 3.2 4.0 5.0 6.3 8.0 9.0 10.0 12.5 16.0 18.0 25.0 31.5

Products overviewIndoor units

Hot waterType Model Product name 15 20 25 32 40 50 63 71 80 100 125 140 200 250

High temperature hydrobox for VRV

- For efficient hot water production and space heating - Ideal for hot water in bathrooms, sinks and for underfloor heating, radiators, air handling units, … - Hot water from 25 to 80°C - “Free” heating and hot water through heat recovery - Possibility to connect thermal solar collectors

HXHD-A

Low temperature hydrobox for VRV

- For high efficiency space heating and cooling - Ideal for hot or cold water in underfloor, air handling units, low temperature radiators … - Hot/cold water from 5° to 45°C

HXY-A (1)Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.(2)Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m

Page 93: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

91VRV catalogue 2015

Port

folio

Type Model Product name 15 20 25 32 40 50 63 71 80 100 125 140 200 250

Ceiling mounted cassette

Round flow cassette

- 360° air discharge for optimum efficiency and comfort - Auto cleaning function ensures high efficiency - Intelligent sensors save energy and maximize comfort - Flexibility to suit every room layout - Lowest installation height in the market!

FXFQ-A

Fully flat cassette - Unique design in the market that integrates fully flat into the ceiling - Perfect integration in standard architectural ceiling tiles - Blend of iconic design and engineering excellence with a white or silver and white finish - Intelligent sensors save energy and maximize comfort - Small capacity unit developed for small or well-insulated rooms - Flexibility to suit every room layout

FXZQ-A

2-way blow ceiling mounted cassette

- Thin, lightweight design installs easily in narrow ceiling spaces - Depth of all units is 620mm, ideal for narrow ceiling spaces - Flexibility to suit every room layout - Reduced energy consumption thanks to DC fan motor - Stylish unit blends easily with any interior. The flaps close entirely when the unit is not operating - Optimum comfort guaranteed with automatic air flow adjustment to the required load

FXCQ-A

Ceiling mounted corner cassette

- 1-way blow unit for corner installation - Compact dimensions enable installation in narrow ceiling voids - Flexible installation thanks to different air discharge options

FXKQ-MA

Concealed ceiling

Small concealed ceiling unit

- Designed for hotel rooms - Compact dimensions enable installation in narrow ceiling voids - Discretely concealed in the ceiling: only the grilles are visible - Flexible installation as the air suction direction can be altered from rear to bottom suction

FXDQ-M9 Slim concealed ceiling unit

- Slim design for flexible installation - Compact dimensions enable installation in narrow ceiling voids - Medium external static pressure up to 44Pa - Only grilles are visible - Small capacity unit developed for small of well-insulated rooms - Reduced energy consumption thanks to DC fan motor

FXDQ-A

Concealed ceiling unit with high ESP

- Optimum comfort guaranteed no matter the length of ductwork or type of grilles - Automatic air flow adjustment function measures the air volume and static pressure and adjusts it towards the nominal air flow, guaranteeing comfort - High external static pressure up to 150Pa - Only grilles are visible - Reduced energy consumption thanks to DC fan motor - Flexible installation as the air suction direction can be altered from rear to bottom suction - Only 245mm high in the ceiling

FXSQ-A

Concealed ceiling unit with high ESP

- ESP up to 200, ideal for large sized spaces - Optimum comfort guaranteed no matter the length of ductwork or type of grilles, thanks to automatic air flow adjustment - Only grilles are visible - Reduced energy consumption thanks to DC fan motor - Flexible installation as the air suction direction can be altered from rear to bottom suction

FXMQ-P7

Concealed ceiling unit with high ESP

- ESP up to 270, ideal for extra large sized spaces - Only grilles are visible - Large capacity unit: up to 31.5 kW heating capacity

FXMQ-MA

Wall mounted

Wall mounted unit - For rooms with no false ceilings nor free floor space - Flat, stylish front panel blends easily with any interior décor and is more easy to clean - Can easily be installed in both new and refurbishment projects - Small capacity unit developed for small of well-insulated rooms - Reduced energy consumption thanks to DC fan motor - The air is comfortably spread up- and downwards thanks to 5 different discharge angles

FXAQ-P

Ceiling suspended

Ceiling suspended unit

- For wide rooms with no false ceilings nor free floor space - Ideal for comfortable air flow in wide rooms thanks to Coanda effect - Even rooms with ceilings up to 3.8m can be heated up or cooled down very easily! - Can easily be installed in both new and refurbishment projects - Can even be mounted in corners or narrow spaces without any problem - Reduced energy consumption thanks to DC fan motor

FXHQ-A

4-way blow ceiling suspended unit

- Unique Daikin unit for high rooms with no false ceilings nor free floor space - Even rooms with ceilings up to 3.5m can be heated up or cooled down very easily! - Can easily be installed in both new and refurbishment projects - Flexibility to suit every room layout - Reduced energy consumption thanks to DC fan motor

FXUQ-A

Floor standing

Floor standing unit - For perimeter zone air conditioning - Can be installed in front of glass walls or free standing as both the front and the back are finished - Ideal for installation beneath a window - Stylish unit blends easily with any interior - Requires very little installation space - Wall mounted installation facilitates cleaning beneath the unit

FXLQ-P

Concealed floor standing unit

- Ideal for installation in offices, hotels and residential applications - Discretely concealed in the wall, leaving only the suction and discharge grilles visible - Can even be installed underneath a window - Requires very little installation space as the depth is only 200mm - High ESP allows flexible installation

FXNQ-A

Cooling capacity (kW)1 1.7 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2 14.0 16.0 22.4 28.0

Heating capacity (kW)2 1.9 2.5 3.2 4.0 5.0 6.3 8.0 9.0 10.0 12.5 16.0 18.0 25.0 31.5

Indoor units

Capacity class (kW)

Type Model Product name 15 20 25 32 40 50 63 71 80 100 125 140 200 250

High temperature hydrobox for VRV

- For efficient hot water production and space heating - Ideal for hot water in bathrooms, sinks and for underfloor heating, radiators, air handling units, … - Hot water from 25 to 80°C - “Free” heating and hot water through heat recovery - Possibility to connect thermal solar collectors

HXHD-A

Low temperature hydrobox for VRV

- For high efficiency space heating and cooling - Ideal for hot or cold water in underfloor, air handling units, low temperature radiators … - Hot/cold water from 5° to 45°C

HXY-A

Page 94: VRV catalogue 2015 - Daikin Air Conditioning | Daikin AC€¦ · VRV catalogue 2015 7 Introduction VRV Xpress quick design and quotation tool VRV Xpress is a software tool that allows

FSCCarbon

Balanced Paper

VRV catalogue 2015

Redefining efficiency in climate control

Daikin U

KVRV catalogue 2015

Daikin products are distributed by:The present catalogue is drawn up by way of information only and does

not constitute an offer binding upon Daikin UK. Daikin UK has compiled the

content of this catalogue to the best of its knowledge. No express or implied

warranty is given for the completeness, accuracy, reliability or fitness for

particular purpose of its content and the products and services presented

therein. Specifications are subject to change without prior notice. Daikin UK

explicitly rejects any liability for any direct or indirect damage, in the broadest

sense, arising from or related to the use and/or interpretation of this catalogue.

All content is copyrighted by Daikin UK.

Daikin Airconditioning UK Limited The Heights Brooklands Weybridge Surrey KT13 0NY Tel 0845 6419000 Fax 0845 6419009 daikin.co.uk

UKE

PCEN

15-9

88 /

03.

15 /

Des

ignH

Q. C

opyr

ight

201

5 D

aiki

nPr

inte

d in

the

UK

on F

SC c

ertif

ied

pape

r fro

m s

usta

inab

le s

ourc

es.

Scotland Region

0845 641 9330

Northern Region

0845 641 9340

Midlands Region

0845 641 9370

Western Region

0845 641 9320

North London

0845 641 9360

South London

0845 641 9355

Daikin units comply with the European regulations that guarantee the safety of the product.

For Air curtains, VAMS and Applied products visit www.eca.gov.uk/etlFor Split, Sky Air and VRV units check and print your own eligibility statement for ECA at www.daikin.co.uk/eca