Larisa Vrv

22
Produced on 20/11/2007 with VRV Xpress V2.4.1 - database Central 5.4 Project name Reference . Client name . Selection parameters of the indoor units can be found under the chapter Indoor unit details Selection parameters of the outdoor units can be found under the chapter Outdoor unit details Only the data published in the data book are correct. This program uses close approximations of these data. 1. Material List Model Qty Description RXYQ12P7W1B 1 Heat pump VRV III P COMPACT RXYQ14P7W1B 2 Heat pump VRV III P COMPACT RXYQ18P7W1B 1 Heat pump VRV III P COMPACT RXYQ20P7W1B 1 Heat pump VRV III P COMPACT RXYQ5P7W1B 1 Heat pump VRV III P COMPACT RXYQ8P7W1B 1 Heat pump VRV III P COMPACT FXZQ50M8 28 Z - 4-way blow ceiling mounted cassette (600x600) VKM100GAV1 1 GA - Ventilation Air Reclaim VKM50GAV1 1 GA - Ventilation Air Reclaim VKM80GAMV1 2 GAM - Ventilation Air Reclaim VKM80GAV1 7 GA - Ventilation Air Reclaim KHRQ22M20T7 7 REFNET branch piping kit KHRQ22M29T7 11 REFNET branch piping kit KHRQ22M64T7 14 REFNET branch piping kit DCS302B51 1 Centralised BRC1D527 28 Wired remote control BYFQ60BW1 28 Decoration panel BHFQ22P1007 1 Outdoor unit multi connection piping kit for 2 outdoors VKM devices are considered as indoor units. They have an influence on the selection of outdoor units, the piping diagram, the wiring diagram and the centralized controller diagram. The VRV Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the VRV Xpress Program. Page 1

description

 

Transcript of Larisa Vrv

Page 1: Larisa Vrv

Produced on 20/11/2007 with VRV Xpress V2.4.1 - database Central 5.4

Project name

Reference .

Client name .

Selection parameters of the indoor units can be found under the chapter Indoor unit detailsSelection parameters of the outdoor units can be found under the chapter Outdoor unit detailsOnly the data published in the data book are correct. This program uses close approximations of these data.

1. Material ListModel Qty Description

RXYQ12P7W1B 1 Heat pump VRV III P COMPACT

RXYQ14P7W1B 2 Heat pump VRV III P COMPACT

RXYQ18P7W1B 1 Heat pump VRV III P COMPACT

RXYQ20P7W1B 1 Heat pump VRV III P COMPACT

RXYQ5P7W1B 1 Heat pump VRV III P COMPACT

RXYQ8P7W1B 1 Heat pump VRV III P COMPACT

FXZQ50M8 28 Z - 4-way blow ceiling mounted cassette (600x600)

VKM100GAV1 1 GA - Ventilation Air Reclaim

VKM50GAV1 1 GA - Ventilation Air Reclaim

VKM80GAMV1 2 GAM - Ventilation Air Reclaim

VKM80GAV1 7 GA - Ventilation Air Reclaim

KHRQ22M20T7 7 REFNET branch piping kit

KHRQ22M29T7 11 REFNET branch piping kit

KHRQ22M64T7 14 REFNET branch piping kit

DCS302B51 1 Centralised

BRC1D527 28 Wired remote control

BYFQ60BW1 28 Decoration panel

BHFQ22P1007 1 Outdoor unit multi connection piping kit for 2 outdoors

VKM devices are considered as indoor units. They have an influence on the selection of outdoor units, the piping diagram, the wiring diagram and the centralized controller diagram.

The VRV Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the VRV Xpress Program.

Page 1

Page 2: Larisa Vrv

2. Indoor Unit Details

2.1. Table of AbbreviationsName Logical name of the device Rq HC Required heating capacity

FCU Device model name HC Available heating capacity (with freeze-up correction)

Tmp C Indoor conditions in cooling (dry bulb temp. / RH) Airflow Supplied airflow at low and high fan speed

Rq TC Required total cooling capacity Sound Sound pressure low and high

TC Available total cooling capacity MCA Minimum Circuit Amps

Rq SC Required sensible cooling capacity WxHxD WidthxHeightxDepth

SC Available sensible cooling capacity Wght Weight of the device

Tmp H Indoor temperature in heating

2.2. Type A - Outdoor Unit - RXYQ20P7W1B

Actual capacity data at conditions and combination ratio (102%) as entered

Name FCU Tmp C Rq TC TC Rq SC SC Tmp H Rq HC HC Airflow Sound MCA WxHxD

°C kW kW kW kW °C kW kW m³/h dBA A mm

Type A - FCU 1 FXZQ50M8 24,0 / 50% n/a 4,4 n/a 3,4 20,0 n/a 4,5 600-840 33-41 0,9 575x286x575

Type A - FCU 2 FXZQ50M8 24,0 / 50% n/a 4,4 n/a 3,4 20,0 n/a 4,5 600-840 33-41 0,9 575x286x575

Type A - FCU 3 FXZQ50M8 24,0 / 50% n/a 4,4 n/a 3,4 20,0 n/a 4,5 600-840 33-41 0,9 575x286x575

Type A - FCU 4 FXZQ50M8 24,0 / 50% n/a 4,4 n/a 3,4 20,0 n/a 4,5 600-840 33-41 0,9 575x286x575

Type A - FCU 5 FXZQ50M8 24,0 / 50% n/a 4,4 n/a 3,4 20,0 n/a 4,5 600-840 33-41 0,9 575x286x575

Type A - FCU 6 FXZQ50M8 24,0 / 50% n/a 4,4 n/a 3,4 20,0 n/a 4,5 600-840 33-41 0,9 575x286x575

Type A - FCU 7 FXZQ50M8 24,0 / 50% n/a 4,4 n/a 3,4 20,0 n/a 4,5 600-840 33-41 0,9 575x286x575

Type A - VKM 1 VKM80GAMV1 24,0 / 50% n/a 7,1 n/a 4,5 20,0 n/a 7,2 640-750 36-36 4,3 1764x387x1214

Type A - VKM 2 VKM80GAMV1 24,0 / 50% n/a 7,1 n/a 4,5 20,0 n/a 7,2 640-750 36-36 4,3 1764x387x1214

Total 45,1 33,1 45,8

Diversified capacity data at conditions as entered and 100% combination ratio

Name TC SC HC

kW kW kW

Type A - FCU 1 4,4 3,5 4,6

Type A - FCU 2 4,4 3,5 4,6

Type A - FCU 3 4,4 3,5 4,6

Type A - FCU 4 4,4 3,5 4,6

Type A - FCU 5 4,4 3,5 4,6

Type A - FCU 6 4,4 3,5 4,6

Type A - FCU 7 4,4 3,5 4,6

Type A - VKM 1 7,1 4,5 7,3

Type A - VKM 2 7,1 4,5 7,3

Total 45,3 33,2 46,6

The VRV Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the VRV Xpress Program.

Page 2

Page 3: Larisa Vrv

2.3. Type B - Outdoor Unit - RXYQ18P7W1B

Actual capacity data at conditions and combination ratio (102%) as entered

Name FCU Tmp C Rq TC TC Rq SC SC Tmp H Rq HC HC Airflow Sound MCA WxHxD

°C kW kW kW kW °C kW kW m³/h dBA A mm

Type B - FCU 1 FXZQ50M8 24,0 / 50% n/a 4,3 n/a 3,4 20,0 n/a 4,1 600-840 33-41 0,9 575x286x575

Type B - FCU 2 FXZQ50M8 24,0 / 50% n/a 4,3 n/a 3,4 20,0 n/a 4,1 600-840 33-41 0,9 575x286x575

Type B - FCU 3 FXZQ50M8 24,0 / 50% n/a 4,3 n/a 3,4 20,0 n/a 4,1 600-840 33-41 0,9 575x286x575

Type B - FCU 4 FXZQ50M8 24,0 / 50% n/a 4,3 n/a 3,4 20,0 n/a 4,1 600-840 33-41 0,9 575x286x575

Type B - FCU 5 FXZQ50M8 24,0 / 50% n/a 4,3 n/a 3,4 20,0 n/a 4,1 600-840 33-41 0,9 575x286x575

Type B - FCU 6 FXZQ50M8 24,0 / 50% n/a 4,3 n/a 3,4 20,0 n/a 4,1 600-840 33-41 0,9 575x286x575

Type B - VKM 1 VKM80GAV1 24,0 / 50% n/a 6,9 n/a 4,4 20,0 n/a 6,6 640-750 37,5-37,5 4,3 1764x387x1214

Type B - VKM 2 VKM80GAV1 24,0 / 50% n/a 6,9 n/a 4,4 20,0 n/a 6,6 640-750 37,5-37,5 4,3 1764x387x1214

Total 39,7 29,2 38,1

Diversified capacity data at conditions as entered and 100% combination ratio

Name TC SC HC

kW kW kW

Type B - FCU 1 4,3 3,4 4,2

Type B - FCU 2 4,3 3,4 4,2

Type B - FCU 3 4,3 3,4 4,2

Type B - FCU 4 4,3 3,4 4,2

Type B - FCU 5 4,3 3,4 4,2

Type B - FCU 6 4,3 3,4 4,2

Type B - VKM 1 6,9 4,4 6,8

Type B - VKM 2 6,9 4,4 6,8

Total 39,9 29,3 39,0

The VRV Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the VRV Xpress Program.

Page 3

Page 4: Larisa Vrv

2.4. Type C - Outdoor Unit - RXYQ14P7W1B

Actual capacity data at conditions and combination ratio (100%) as entered

Name FCU Tmp C Rq TC TC Rq SC SC Tmp H Rq HC HC Airflow Sound MCA WxHxD

°C kW kW kW kW °C kW kW m³/h dBA A mm

Type C - FCU 1 FXZQ50M8 24,0 / 50% n/a 4,7 n/a 3,6 20,0 n/a 4,9 600-840 33-41 0,9 575x286x575

Type C - FCU 2 FXZQ50M8 24,0 / 50% n/a 4,7 n/a 3,6 20,0 n/a 4,9 600-840 33-41 0,9 575x286x575

Type C - FCU 3 FXZQ50M8 24,0 / 50% n/a 4,7 n/a 3,6 20,0 n/a 4,9 600-840 33-41 0,9 575x286x575

Type C - FCU 4 FXZQ50M8 24,0 / 50% n/a 4,7 n/a 3,6 20,0 n/a 4,9 600-840 33-41 0,9 575x286x575

Type C - FCU 5 FXZQ50M8 24,0 / 50% n/a 4,7 n/a 3,6 20,0 n/a 4,9 600-840 33-41 0,9 575x286x575

Type C - VKM 1 VKM100GAV1 24,0 / 50% n/a 9,3 n/a 5,9 20,0 n/a 9,8 820-950 38-38 4,3 1764x387x1214

Total 32,7 23,6 34,2

Diversified capacity data at conditions as entered and 100% combination ratio

Name TC SC HC

kW kW kW

Type C - FCU 1 4,7 3,6 4,9

Type C - FCU 2 4,7 3,6 4,9

Type C - FCU 3 4,7 3,6 4,9

Type C - FCU 4 4,7 3,6 4,9

Type C - FCU 5 4,7 3,6 4,9

Type C - VKM 1 9,3 5,9 9,8

Total 32,7 23,6 34,2

The VRV Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the VRV Xpress Program.

Page 4

Page 5: Larisa Vrv

2.5. Type D - Outdoor Unit - RXYQ14P7W1B

Actual capacity data at conditions and combination ratio (103%) as entered

Name FCU Tmp C Rq TC TC Rq SC SC Tmp H Rq HC HC Airflow Sound MCA WxHxD

°C kW kW kW kW °C kW kW m³/h dBA A mm

Type D - FCU 1 FXZQ50M8 24,0 / 50% n/a 4,6 n/a 3,5 20,0 n/a 4,8 600-840 33-41 0,9 575x286x575

Type D - FCU 2 FXZQ50M8 24,0 / 50% n/a 4,6 n/a 3,5 20,0 n/a 4,8 600-840 33-41 0,9 575x286x575

Type D - FCU 3 FXZQ50M8 24,0 / 50% n/a 4,6 n/a 3,5 20,0 n/a 4,8 600-840 33-41 0,9 575x286x575

Type D - FCU 4 FXZQ50M8 24,0 / 50% n/a 4,6 n/a 3,5 20,0 n/a 4,8 600-840 33-41 0,9 575x286x575

Type D - VKM 1 VKM80GAV1 24,0 / 50% n/a 7,4 n/a 4,7 20,0 n/a 7,6 640-750 37,5-37,5 4,3 1764x387x1214

Type D - VKM 2 VKM80GAV1 24,0 / 50% n/a 7,4 n/a 4,7 20,0 n/a 7,6 640-750 37,5-37,5 4,3 1764x387x1214

Total 33,4 23,5 34,3

Diversified capacity data at conditions as entered and 100% combination ratio

Name TC SC HC

kW kW kW

Type D - FCU 1 4,7 3,6 4,9

Type D - FCU 2 4,7 3,6 4,9

Type D - FCU 3 4,7 3,6 4,9

Type D - FCU 4 4,7 3,6 4,9

Type D - VKM 1 7,5 4,7 7,8

Type D - VKM 2 7,5 4,7 7,8

Total 33,6 23,6 35,2

The VRV Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the VRV Xpress Program.

Page 5

Page 6: Larisa Vrv

2.6. Type E - Outdoor Unit - RXYQ12P7W1B

Actual capacity data at conditions and combination ratio (103%) as entered

Name FCU Tmp C Rq TC TC Rq SC SC Tmp H Rq HC HC Airflow Sound MCA WxHxD

°C kW kW kW kW °C kW kW m³/h dBA A mm

Type E - FCU 1 FXZQ50M8 24,0 / 50% n/a 4,5 n/a 3,5 20,0 n/a 4,1 600-840 33-41 0,9 575x286x575

Type E - FCU 2 FXZQ50M8 24,0 / 50% n/a 4,5 n/a 3,5 20,0 n/a 4,1 600-840 33-41 0,9 575x286x575

Type E - FCU 3 FXZQ50M8 24,0 / 50% n/a 4,5 n/a 3,5 20,0 n/a 4,1 600-840 33-41 0,9 575x286x575

Type E - VKM 1 VKM80GAV1 24,0 / 50% n/a 7,3 n/a 4,6 20,0 n/a 6,5 640-750 37,5-37,5 4,3 1764x387x1214

Type E - VKM 2 VKM80GAV1 24,0 / 50% n/a 7,3 n/a 4,6 20,0 n/a 6,5 640-750 37,5-37,5 4,3 1764x387x1214

Total 28,1 19,6 25,1

Diversified capacity data at conditions as entered and 100% combination ratio

Name TC SC HC

kW kW kW

Type E - FCU 1 4,6 3,5 4,2

Type E - FCU 2 4,6 3,5 4,2

Type E - FCU 3 4,6 3,5 4,2

Type E - VKM 1 7,3 4,6 6,7

Type E - VKM 2 7,3 4,6 6,7

Total 28,3 19,7 25,9

The VRV Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the VRV Xpress Program.

Page 6

Page 7: Larisa Vrv

2.7. Type F - Outdoor Unit - RXYQ8P7W1B

Actual capacity data at conditions and combination ratio (90%) as entered

Name FCU Tmp C Rq TC TC Rq SC SC Tmp H Rq HC HC Airflow Sound MCA WxHxD

°C kW kW kW kW °C kW kW m³/h dBA A mm

Type F - FCU 1 FXZQ50M8 24,0 / 50% n/a 4,4 n/a 3,4 20,0 n/a 5,2 600-840 33-41 0,9 575x286x575

Type F - FCU 2 FXZQ50M8 24,0 / 50% n/a 4,4 n/a 3,4 20,0 n/a 5,2 600-840 33-41 0,9 575x286x575

Type F - VKM 1 VKM80GAV1 24,0 / 50% n/a 7,1 n/a 4,5 20,0 n/a 8,3 640-750 37,5-37,5 4,3 1764x387x1214

Total 15,9 11,4 18,7

Diversified capacity data at conditions as entered and 100% combination ratio

Name TC SC HC

kW kW kW

Type F - FCU 1 4,4 3,4 5,2

Type F - FCU 2 4,4 3,4 5,2

Type F - VKM 1 7,1 4,5 8,3

Total 15,9 11,4 18,7

The VRV Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the VRV Xpress Program.

Page 7

Page 8: Larisa Vrv

2.8. Type G - Outdoor Unit - RXYQ5P7W1B

Actual capacity data at conditions and combination ratio (80%) as entered

Name FCU Tmp C Rq TC TC Rq SC SC Tmp H Rq HC HC Airflow Sound MCA WxHxD

°C kW kW kW kW °C kW kW m³/h dBA A mm

Type G - FCU 1 FXZQ50M8 24,0 / 50% n/a 4,2 n/a 3,3 20,0 n/a 5,4 600-840 33-41 0,9 575x286x575

Type F - VKM 1 VKM50GAV1 24,0 / 50% n/a 4,2 n/a 2,7 20,0 n/a 5,4 440-500 36-36 4,3 1764x387x832

Total 8,4 6,0 10,8

Diversified capacity data at conditions as entered and 100% combination ratio

Name TC SC HC

kW kW kW

Type G - FCU 1 4,2 3,3 5,4

Type F - VKM 1 4,2 2,7 5,4

Total 8,4 6,0 10,8

The VRV Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the VRV Xpress Program.

Page 8

Page 9: Larisa Vrv

3. Outdoor Unit Details

3.1. Table of AbbreviationsName Logical name of the device Refrig Standard factory refrigerant charge (5m actual piping length),

Model Device model name excluding extra refrigerant charge

Comb Combination percentage For calculation of extra refrigerant charge refer to the VRV databook

Tmp C Outdoor temperature in cooling (dry bulb) PS Power supply (voltage and phases)

CC Cooling capacity Run Amps Running Amps

EER EER at selection and nominal conditions St Curr Starting current

Tmp H Outdoor temperature in heating (dry bulb) Fuses Fuses

HC Heating capacity (with freeze-up correction) WxHxD WidthxHeightxDepth

COP COP at selection and nominal conditions Wght Weight of the device

Piping Largest distance from indoor unit to outdoor unit

3.2. Outdoor DetailsName Model Comb Tmp C CC EER Tmp H HC COP Piping Refrig

% °C kW °C kW m kg

Type A - Outdoor Unit RXYQ20P7W1B 102 37,0 49,6 3,7 / 3,7 -7,0 45,8 3,1 / 4,1 45,0 16,3

* RXYQ12P7W1B

* RXYQ8P7W1B

Type B - Outdoor Unit RXYQ18P7W1B 102 37,0 43,5 3 / 3 -7,0 38,1 2,9 / 3,7 45,0 12,7

Type C - Outdoor Unit RXYQ14P7W1B 100 37,0 34,9 3,2 / 3,2 -7,0 34,2 2,8 / 4 45,0 12,3

Type D - Outdoor Unit RXYQ14P7W1B 103 37,0 35,7 3,2 / 3,2 -7,0 34,3 2,8 / 4 45,0 12,3

Type E - Outdoor Unit RXYQ12P7W1B 103 37,0 30,0 3,5 / 3,5 -7,0 25,1 3,1 / 4 45,0 8,6

Type F - Outdoor Unit RXYQ8P7W1B 90 37,0 19,5 4 / 4 -7,0 20,8 3,2 / 4,3 45,0 7,7

Type G - Outdoor Unit RXYQ5P7W1B 80 37,0 12,2 4 / 4 -7,0 13,5 2,9 / 4 45,0 6,2

Name Model PS Run Amps St Curr Fuses WxHxD Wght

A A mm kg

Type A - Outdoor Unit RXYQ20P7W1B 400V 3Nph 1860x1680x765 427

* RXYQ12P7W1B 14 75 cfr. local legislation

* RXYQ8P7W1B 7,5 cfr. local legislation

Type B - Outdoor Unit RXYQ18P7W1B 400V 3Nph 24,2 85 cfr. local legislation 1240x1680x765 325

Type C - Outdoor Unit RXYQ14P7W1B 400V 3Nph 18,4 84 cfr. local legislation 1240x1680x765 317

Type D - Outdoor Unit RXYQ14P7W1B 400V 3Nph 18,4 84 cfr. local legislation 1240x1680x765 317

Type E - Outdoor Unit RXYQ12P7W1B 400V 3Nph 14 75 cfr. local legislation 930x1680x765 240

Type F - Outdoor Unit RXYQ8P7W1B 400V 3Nph 7,5 cfr. local legislation 930x1680x765 187

Type G - Outdoor Unit RXYQ5P7W1B 400V 3Nph 5,1 cfr. local legislation 635x1680x765 159

The VRV Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the VRV Xpress Program.

Page 9

Page 10: Larisa Vrv

4. Piping DiagramsPipes marked with * in the diagrams must be connected to the device with a reducing joint.

4.1. Piping Type A - Outdoor Unit

RXYQ12P7W1B

RXYQ8P7W1B

Ty pe A - Outdoor UnitRXYQ20P7W1B

12,7x28,6

9,5x19,1

BHFQ22P1007

KHRQ22M64T7

15,9x28,6Ty pe A - FCU 1

FXZQ50M86,4x12,7

KHRQ22M64T7

15,9x28,6Ty pe A - FCU 2

FXZQ50M86,4x12,7

KHRQ22M64T7

12,7x28,6Ty pe A - FCU 3

FXZQ50M86,4x12,7

KHRQ22M64T7

12,7x28,6Ty pe A - FCU 4

FXZQ50M86,4x12,7

KHRQ22M64T7

12,7x28,6Ty pe A - FCU 5

FXZQ50M86,4x12,7

KHRQ22M29T7

9,5x22,2Ty pe A - FCU 6

FXZQ50M86,4x12,7

KHRQ22M29T7

9,5x22,2Ty pe A - FCU 7

FXZQ50M86,4x12,7

KHRQ22M20T7

9,5x19,1Ty pe A - VKM 1VKM80GAMV1

6,4x12,7

Ty pe A - VKM 2VKM80GAMV1

6,4x12,7

4.2. Piping Type B - Outdoor Unit

Ty pe B - Outdoor UnitRXYQ18P7W1B

KHRQ22M64T7

15,9x28,6Ty pe B - FCU 1

FXZQ50M86,4x12,7

KHRQ22M64T7

12,7x28,6Ty pe B - FCU 2

FXZQ50M86,4x12,7

KHRQ22M64T7

12,7x28,6Ty pe B - FCU 3

FXZQ50M86,4x12,7

KHRQ22M64T7

12,7x28,6Ty pe B - FCU 4

FXZQ50M86,4x12,7

KHRQ22M29T7

9,5x22,2Ty pe B - FCU 5

FXZQ50M86,4x12,7

KHRQ22M29T7

9,5x22,2Ty pe B - FCU 6

FXZQ50M86,4x12,7

KHRQ22M20T7

9,5x19,1Ty pe B - VKM 1

VKM80GAV16,4x12,7

Ty pe B - VKM 2VKM80GAV1

6,4x12,7

The VRV Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the VRV Xpress Program.

Page 10

Page 11: Larisa Vrv

4.3. Piping Type C - Outdoor Unit

Ty pe C - Outdoor UnitRXYQ14P7W1B

KHRQ22M64T7

12,7x28,6Ty pe C - FCU 1

FXZQ50M86,4x12,7

KHRQ22M64T7

12,7x28,6Ty pe C - FCU 2

FXZQ50M86,4x12,7

KHRQ22M29T7

9,5x22,2Ty pe C - FCU 3

FXZQ50M86,4x12,7

KHRQ22M29T7

9,5x22,2Ty pe C - FCU 4

FXZQ50M86,4x12,7

KHRQ22M20T7

9,5x19,1Ty pe C - FCU 5

FXZQ50M86,4x12,7

Ty pe C - VKM 1VKM100GAV1

6,4x12,7

4.4. Piping Type D - Outdoor Unit

Ty pe D - Outdoor UnitRXYQ14P7W1B

KHRQ22M64T7

12,7x28,6Ty pe D - FCU 1

FXZQ50M86,4x12,7

KHRQ22M64T7

12,7x28,6Ty pe D - FCU 2

FXZQ50M86,4x12,7

KHRQ22M29T7

9,5x22,2Ty pe D - FCU 3

FXZQ50M86,4x12,7

KHRQ22M29T7

9,5x22,2Ty pe D - FCU 4

FXZQ50M86,4x12,7

KHRQ22M20T7

9,5x19,1Ty pe D - VKM 1

VKM80GAV16,4x12,7

Ty pe D - VKM 2VKM80GAV1

6,4x12,7

4.5. Piping Type E - Outdoor Unit

Ty pe E - Outdoor UnitRXYQ12P7W1B

KHRQ22M64T7

12,7x28,6Ty pe E - FCU 1

FXZQ50M86,4x12,7

KHRQ22M29T7

9,5x22,2Ty pe E - FCU 2

FXZQ50M86,4x12,7

KHRQ22M29T7

9,5x22,2Ty pe E - FCU 3

FXZQ50M86,4x12,7

KHRQ22M20T7

9,5x19,1Ty pe E - VKM 1

VKM80GAV16,4x12,7

Ty pe E - VKM 2VKM80GAV1

6,4x12,7

The VRV Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the VRV Xpress Program.

Page 11

Page 12: Larisa Vrv

4.6. Piping Type F - Outdoor Unit

Ty pe F - Outdoor UnitRXYQ8P7W1B

KHRQ22M29T7

9,5x19,1Ty pe F - FCU 1

FXZQ50M86,4x12,7

KHRQ22M20T7

9,5x15,9Ty pe F - FCU 2

FXZQ50M86,4x12,7

Ty pe F - VKM 1VKM80GAV1

6,4x12,7

4.7. Piping Type G - Outdoor Unit

Ty pe G - Outdoor UnitRXYQ5P7W1B

KHRQ22M20T7

9,5x15,9Ty pe G - FCU 1

FXZQ50M86,4x12,7

Ty pe F - VKM 1VKM50GAV1

6,4x12,7

5. Wiring Diagrams

P1P2 = 16-2 AWG 2 core non screened stranded wire (non polarity wiring system)F1F2 = 16-2 AWG 2 core non screened stranded wire (non polarity wiring system)

5.1. Centralized Controllerscentralised DCS302B51

centralised Ty pe A - Outdoor UnitRXYQ20P7W1B

Ty pe B - Outdoor UnitRXYQ18P7W1B

Ty pe C - Outdoor UnitRXYQ14P7W1B

Ty pe D - Outdoor UnitRXYQ14P7W1B

Ty pe E - Outdoor UnitRXYQ12P7W1B

Ty pe F - Outdoor UnitRXYQ8P7W1B

Ty pe G - Outdoor UnitRXYQ5P7W1B

F1,F2

L,N

OUT F1,F2

OUT F1,F2

OUT F1,F2

OUT F1,F2

OUT F1,F2

OUT F1,F2

OUT F1,F2

The VRV Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the VRV Xpress Program.

Page 12

Page 13: Larisa Vrv

5.2. Wiring Type A - Outdoor Unit

RXYQ12P7W1B

RXYQ8P7W1B

Ty pe A - Outdoor UnitRXYQ20P7W1B

Q1,Q2

Q1,Q2

L1,L2,L3,N

22,7A 3Nph

L1,L2,L3,N

18,5A 3Nph

F1,F2IN F1,F2

Ty pe A - FCU 1FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe A - FCU 2FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe A - FCU 3FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe A - FCU 4FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe A - FCU 5FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe A - FCU 6FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe A - FCU 7FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe A - VKM 1VKM80GAMV1

L,N

F1,F2

Ty pe A - VKM 2VKM80GAMV1

L,N

14,9A 1ph

OUT F1,F2

to centralized controller

The VRV Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the VRV Xpress Program.

Page 13

Page 14: Larisa Vrv

5.3. Wiring Type B - Outdoor Unit

Ty pe B - Outdoor UnitRXYQ18P7W1B

L1,L2,L3,N 32,5A 3Nph

F1,F2IN F1,F2

Ty pe B - FCU 1FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe B - FCU 2FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe B - FCU 3FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe B - FCU 4FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe B - FCU 5FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe B - FCU 6FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe B - VKM 1VKM80GAV1

L,N

F1,F2

Ty pe B - VKM 2VKM80GAV1

L,N

14A 1ph

OUT F1,F2

to centralized controller

The VRV Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the VRV Xpress Program.

Page 14

Page 15: Larisa Vrv

5.4. Wiring Type C - Outdoor Unit

Ty pe C - Outdoor UnitRXYQ14P7W1B

L1,L2,L3,N 31,5A 3Nph

F1,F2IN F1,F2

Ty pe C - FCU 1FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe C - FCU 2FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe C - FCU 3FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe C - FCU 4FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe C - FCU 5FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe C - VKM 1VKM100GAV1

L,N

8,8A 1ph

OUT F1,F2

to centralized controller

5.5. Wiring Type D - Outdoor Unit

Ty pe D - Outdoor UnitRXYQ14P7W1B

L1,L2,L3,N 31,5A 3Nph

F1,F2IN F1,F2

Ty pe D - FCU 1FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe D - FCU 2FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe D - FCU 3FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe D - FCU 4FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe D - VKM 1VKM80GAV1

L,N

F1,F2

Ty pe D - VKM 2VKM80GAV1

L,N

12,2A 1ph

OUT F1,F2

to centralized controller

The VRV Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the VRV Xpress Program.

Page 15

Page 16: Larisa Vrv

5.6. Wiring Type E - Outdoor Unit

Ty pe E - Outdoor UnitRXYQ12P7W1B

L1,L2,L3,N 22,7A 3Nph

F1,F2IN F1,F2

Ty pe E - FCU 1FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe E - FCU 2FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe E - FCU 3FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe E - VKM 1VKM80GAV1

L,N

F1,F2

Ty pe E - VKM 2VKM80GAV1

L,N

11,3A 1ph

OUT F1,F2

to centralized controller

5.7. Wiring Type F - Outdoor Unit

Ty pe F - Outdoor UnitRXYQ8P7W1B

L1,L2,L3,N 18,5A 3Nph

F1,F2IN F1,F2

Ty pe F - FCU 1FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe F - FCU 2FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe F - VKM 1VKM80GAV1

L,N

6,1A 1ph

OUT F1,F2

to centralized controller

5.8. Wiring Type G - Outdoor Unit

Ty pe G - Outdoor UnitRXYQ5P7W1B

L1,L2,L3,N 11,9A 3Nph

F1,F2IN F1,F2

Ty pe G - FCU 1FXZQ50M8

L,N

BRC1D527P1,P2

F1,F2

Ty pe F - VKM 1VKM50GAV1

L,N

5,2A 1ph

OUT F1,F2

to centralized controller

The VRV Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the VRV Xpress Program.

Page 16

Page 17: Larisa Vrv

6. Device Options

6.1. Outdoor Unit OptionsModel Description Used by

BHFQ22P1007 Outdoor unit multi connection piping kit for 2 outdoors Type A - Outdoor Unit [RXYQ20P7W1B]

6.2. Indoor Unit OptionsModel Description Used by

BYFQ60BW1 Decoration panel Type A - FCU 2 [FXZQ50M8] Type A - FCU 3 [FXZQ50M8] Type A - FCU 4 [FXZQ50M8]

Type A - FCU 5 [FXZQ50M8] Type A - FCU 6 [FXZQ50M8] Type A - FCU 1 [FXZQ50M8]

Type B - FCU 1 [FXZQ50M8] Type B - FCU 2 [FXZQ50M8] Type A - FCU 7 [FXZQ50M8]

Type B - FCU 3 [FXZQ50M8] Type B - FCU 4 [FXZQ50M8] Type B - FCU 5 [FXZQ50M8]

Type B - FCU 6 [FXZQ50M8] Type C - FCU 1 [FXZQ50M8] Type C - FCU 2 [FXZQ50M8]

Type C - FCU 3 [FXZQ50M8] Type C - FCU 4 [FXZQ50M8] Type C - FCU 5 [FXZQ50M8]

Type D - FCU 1 [FXZQ50M8] Type D - FCU 2 [FXZQ50M8] Type D - FCU 3 [FXZQ50M8]

Type D - FCU 4 [FXZQ50M8] Type E - FCU 1 [FXZQ50M8] Type E - FCU 2 [FXZQ50M8]

Type E - FCU 3 [FXZQ50M8] Type F - FCU 1 [FXZQ50M8] Type F - FCU 2 [FXZQ50M8]

Type G - FCU 1 [FXZQ50M8]

The VRV Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the VRV Xpress Program.

Page 17