Catalog Fte Networks
-
Upload
ftemaximal -
Category
Documents
-
view
236 -
download
6
description
Transcript of Catalog Fte Networks
Structured cablingCables .................................................. 02
Patch cords ........................................... 04
Connectors
• Keystone jack ............................. 06
• RJ45 .............................................. 08
19” patch panels ................................. 10
Telecommunication outlets .............. 12
CabinetsServer cabinets .................................. 14
Multipurpose cabinets ...................... 15
Wall cabinets ...................................... 16
Accessories ......................................... 17
Telecommunication cabinet kits ...... 18
Power distribution units
Basic series .......................................... 21
Vertical series ...................................... 22
Remote series .................................... 23
Index of references ..................... 24
Index
Evolving for the professionalSince the beginning of Fte maximal in 1965 we have been growing in the market in an un-stoppable way led by the best installers in the TV signal reception and distribution sector. Today, we want to support and lead the data installations market in the same way, making the trademark a guaranteed success for thou-sands of installers worldwide, who want to ex-pand their business or who already know this technology.
Structuredcabling
Cables
Patch cords
Connectors
• Keystone jacks• RJ45
19” patch panels
Telecommunication outlets
Structured cabling
Networks
02. / Infrastructure for data networks
C A B L E S
Cables The LAN cable is formed by four pairs of annealed and stretched copper, recovered by a protectivecolored plastic film. The twisted of the insulated pairs cancels the interferences from the external sources and the crosstalk between the adjacent pairs. The different constructions of cables determine theircapacity of transmission.
Easy removalThe design of 305 meter box allows for easy cable pulling withno kinks.
RegulationThe cable reels of Fte Networks meet all standards of structured cable: TIA/EIA-568-B, EN 50.173, ISO 11.801, 2nd ed.
Please check the available certificates in http://networks.ftemaximal.com
Complete solutionThe Fte Networks cables are completed with branches of related products, which are associated to each one of the construction and communication technologies. This provides complete solutions, from cables to the connectors, to pacth panels and other elements of the installation.
MarkedThe cover marked allows the cable identification once the installation is done, likewise the cable cut due to its metric marked.
CENELECAENOR
TIA / EIA
Structured cabling
Networks
Infrastructure for data networks / .03
C A B L E S
Articles chart for LAN cable, bare cooper
Code Reference Description
2220300 CA-5E-U-1000FT-GY Reel of LAN Cable cat. 5e U/UTP in PVC. Box 305 m. Grey color 24 AWG.
2220302 CA-6-U-1000FT-GY Reel of LAN Cable cat. 6 U/UTP in PVC. Box 305 m. Grey color 23 AWG.
2220304CA-6-U-1000FT-LSZH-GY
Reel of LAN cat. 6 U/UTP in LSZH(halogen free). Box 305 m.Grey color 23 AWG.
2220305CA-6-F-1000FT-LSZH-GY
Reel of LAN cat. 6 F/UTP in LSZH(halogen free). Box 305 m.Grey color 23 AWG.
2220307CA-6A-SF-1000FT-LSZH-GY
Reel of LAN cable cat. 6A in LSZH(halogen free). Box 305m.Grey color, 23AWG
2220309CA-7-SF-1000FT-LSZH-GY
Reel of LAN cable cat. 7 in LSZH(halogen free). Box 305m.Grey color, 23AWG
Frequency(MHz)
RL (dB)min.
Attenuation(dB/100m)
max.
NEXT(dB)
ACR(dB)
1 17,0 2,03 62,30 60,30
4 18,8 4,04 53,26 49,20
8 19,7 5,76 48,75 43,00
10 20,0 6,46 47,30 40,80
16 20,0 8,24 44,30 36,10
20 20,0 9,26 42,78 33,50
25 19,3 10,41 41,33 30,90
31,25 18,6 11,72 39,87 28,20
62,5 16,5 16,99 35,36 18,40
100 15,1 21,97 32,29 10,30
Frequency(MHz)
RL (dB)min.
Attenuation(dB/100m)
max.
NEXT(dB)
ACR(dB)
1 20,0 2,02 74,30 72,28
4 23,0 3,78 65,27 61,49
8 24,5 5,32 60,75 55,43
10 25,0 5,95 59,30 53,35
16 25,0 7,55 56,24 48,68
20 25,0 8,47 54,78 46,31
25 24,3 9,51 53,33 43,83
31,25 23,6 10,67 51,88 41,20
62,5 21,5 15,38 47,36 31,98
100 20,1 19,80 44,30 24,50
250 17,3 32,84 38,33 5,48
CAT. 5e U/UTP
CAT. 6A S/FTP
CAT. 6 U/UTP and CAT. 6 F/UTP
CAT. 7 S/FTP
Section 5e U/UTP
Section 6 U/UTP
Section 6 F/UTP
Section 6A & 7 S/FTP
Frequency(MHz)
RL (dB)min.
Attenuation(dB/100m)
max.
NEXT(dB)
TCL(dB)
4 23,0 3,8 78,00 30,00
8 24,5 5,3 78,00 28,00
10 25,0 5,9 78,00 27,00
16 26,0 7,5 78,00 26,00
20 26,5 8,4 78,00 22,00
31,5 27,5 10,5 78,00 20,00
62,5 29,0 15,0 75,50 19,00
100 30,0 19,1 72,40 17,00
200 31,5 27,6 67,90 /
300 32,4 34,3 65,24 /
500 33,5 45,3 60,73 /
Frequency(MHz)
RL (dB)min.
Attenuation(dB/100m)
max.
NEXT(dB)
TCL(dB)
4 23,0 3,7 78,00 30,00
8 24,5 5,2 78,00 28,00
10 27,2 5,9 78,00 27,00
16 25,0 7,4 78,00 26,00
20 25,0 8,3 78,00 22,00
31,5 23,6 10,5 78,00 20,00
62,5 21,5 14,9 75,50 19,00
100 20,1 19,0 72,40 17,00
200 18,0 27,5 67,90 /
300 34,2 34,2 65,24 /
600 50,1 50,1 60,73 /
Structured cabling
Networks
04. / Infrastructure for data networks
P AT C H C O R D S
Patch cords
The patch cords are constructed of four pairs which, at the same time, are made of seven filaments of the highest purity copper. This makes them more mal-leable and they can be easily installed and adapted to the space restrictions inside the rack enclosures.
LSZH patch cordsThe cover of the patch cords from Fte Networks is always LSZH, which is the safety guarantee at any installation.
Own identification system - CCSFte Networks has created a new economic and effective coding system that allows for individual identification of the installed patch cords. The patch cords are grey and have nine different sizes, in the range, therefore covering any application.
Individual packaging and labelingIndividual labelling allows for traceability of the product from factory manufacture, to storage, right through to installation.
RegulationThe cable reels of Fte Networks meet all standards of structured cable: TIA/EIA-568-B, EN 50.173, ISO 11.801,2nd ed.
Please check the available certificates in http://networks.ftemaximal.com
CENELECAENOR
TIA / EIA
Structured cabling
Networks
Infrastructure for data networks / .05
P AT C H C O R D S
Code Reference Description
2220010 PC-5e-U-MT-0.5GY Patch cord RJ45-RJ45. 0,5 m 1/50
2220012 PC-5e-U-MT-1GY Patch cord RJ45-RJ45. 1 m 1/35
2220013 PC-5e-U-MT-1.5GY Patch cord RJ45-RJ45.1,5 m 1/30
2220014 PC-5e-U-MT-2GY Patch cord RJ45-RJ45. 2 m 1/20
2220016 PC-5e-U-MT-3GY Patch cord RJ45-RJ45. 3 m 1/15
2220018 PC-5e-U-MT-5GY Patch cord RJ45-RJ45. 5 m 1/10
2220194 PC-5e-U-MT-7.5GY Patch cord RJ45-RJ45. 7,5 m 1/15
2220195 PC-5e-U-MT-10GY Patch cord RJ45-RJ45. 10 m 1/12
2220196 PC-5e-U-MT-15GY Patch cord RJ45-RJ45, 15 m 1/10
Code Reference Description
2220080 PC-6-U-MT-0.5GY Patch cord RJ45-RJ 45. 0,5 m 1/50
2220082 PC-6-U-MT-1GY Patch cord RJ45-RJ45. 1 m 1/35
2220083 PC-6-U-MT-1.5GY Patch cord RJ45-RJ45. 1,5 m 1/20
2220084 PC-6-U-MT-2GY Patch cord RJ45-RJ45. 2 m 1/15
2220086 PC-6-U-MT-3GY Patch cord RJ45-RJ45. 3 m 1/10
2220088 PC-6-U-MT-5GY Patch cord RJ45-RJ45. 5 m 1/7
2220188 PC-6-U-MT-7.5GY Patch cord RJ45-RJ45. 7,5 m 1/12
2220189 PC-6-U-MT-10GY Patch cord RJ45-RJ45. 10 m 1/10
2220190 PC-6-U-MT-15GY Patch cord RJ45-RJ45. 15 m 1/6
Code Reference Description
2220150 PC-6-F-MT-0.5GY Patch cord RJ45-RJ45. 0,5 m 1/50
2220152 PC-6-F-MT-1GY Patch cord RJ45-RJ45. 1 m 1/35
2220153 PC-6-F-MT-1.5GY Patch cord RJ45-RJ45. 1,5 m 1/20
2220154 PC-6-F-MT-2GY Patch cord RJ45-RJ45. 2 m 1/15
2220156 PC-6-F-MT-3GY Patch cord RJ45-RJ45. 3 m 1/10
2220158 PC-6-F-MT-5GY Patch cord RJ45-RJ45. 5 m 1/7
2220191 PC-6-F-MT-7.5GY Patch cord RJ45-RJ45. 7,5 m 1/12
2220192 PC-6-F-MT-10GY Patch cord RJ45-RJ45.10 m 1/10
2220193 PC-6-F-MT-15GY Patch cord RJ45-RJ45. 15 m 1/6
Code Reference Description
2220226 CCS-WH Color coding system, white 36/4320
2220228 CCS-BK Color coding system, black 36/4320
2220230 CCS-YL Color coding system, yellow 36/4320
2220232 CCS-RD Color coding system, red 36/4320
2220234 CCS-BL Color coding system, blue 36/4320
2220236 CCS-GN Color coding system, green 36/4320
2220238 CCS-MC Color coding system, multicolor 36/4320
Articles chart for patch cords
5e U/UTP
6 U/UTP
6 F/UTP
Packaging
Packaging
Packaging
Packaging
Note: more colors and technologies available for project.
LSZH
Structured cabling
Networks
06. / Infrastructure for data networks
C O N N E C T O R S
Connectors for each applicationThe connector range from Fte Networks can be used in any installation. The keystone jacks are suitable for all the technologies that can be found in any installation.
Tooless connectors,180º, shielded or unshielded, for the different categories.
VersatilityThe universal anchorage system allows for adapting the connector to different products of the data network range, using only one connector, we can make connections in patch panels and telecommunication outlets.
Individual packaging and labelingIndividual labelling allows it makes possible the storage and tra-ceability of the goods from the moment they go out from factory up to the installation.
For easier logistics, ten keystone jacks are inside a larger bag, which is labelled also.
Comunication securityThe construction of the connector, which is adapted in order to lodge the connectors RJ11, RJ12 and RJ45, assures communication reliability higher than the indicated in the corresponding standard (ISO 11801, 2nd ed.; EN50.173)
CENELECAENOR
TIA / EIA
Keystone jack
The distribution of the wires improves the insu-lation between the signals that are sent through them. In the same way, the minimum untwisted of the cable avoids the geometry loss of the pairsthat would result into crosstalk effects that could damage the communication.
Structured cabling
Networks
Infrastructure for data networks / .07
C O N N E C T O R S
Articles chart for keystone jack
Code Category Reference Description
2220200
5e UTP
KJT-5e-U-WH Tooless keystone jack 10/100
2220201 KJR-5e-U-WH* Unshielded keystone jack 180º
10/100
2220202 KJK-5e-U-WH Unshielded keystone jack 90º
10/100
Code Category Reference Description
2220204
6 UTP
KJT-6-U-WH Tooless keystone jack 10/100
2220299 KJR-6-U-WH* Unshielded keystone jack 180º
10/100
Code Category Reference Description
2220296
6 FTP
KJK-6-F-SI Shielded keystone jack 90º 10/100
2220297 KJR-6-F-SI* Shielded keystone jack 180º 10/100
Code Reference Description
2220205 KJR-6A-F-SI Shieded cat.6A keystone jack 180º
10/100
Code Reference Description
0705250 HT Insertion and cutting tool for keystone jack
1
* Compatible with patch panel ref. PPC-U/F (see page 11)
Packaging
Packaging
Packaging
Packaging
Packaging
Structured cabling
NetworksC O N N E C T O R S
08. / Infrastructure for data networks
RJ45 Connector
The RJ45 connector has over time adapted to the different technologies, being a valid standard, in its external frame, for categories 4, 5, 5e and 6.
Two diagrams can define the wiring standard of the wires: 568A or 568B. The most used one is the 568B
Easy assemblingThe connectors belonging to the category 6 have assembling guides that make the connection easy and guaranty a quality communication.
Individual packaging and labelingEach bag has only 10 units for its correct storage and traceability. In the case of connectors with category 6, the 10 guides are separated in individual bags.
Connection standards in connectors RJ45The wiring standards for RJ45 connectors can be wither 568A or 568B for each installation, it is essential to make.
Regulation
All the connectors RJ45 are designed and manufactured for a longer life than the one set in the current standard.
CENELECAENOR
TIA / EIA
568B
568A
Structured cabling
Networks C O N N E C T O R S
Infrastructure for data networks / .09
568B
568A
Code Category Reference Description Packaging
2220208 5e UTP RJ45-5e-U Unshielded RJ45plug 23&26AWG
10/1200
2220207 6 UTP RJ45-6-U Unshielded RJ45plug 23&26AWG
10/1200
2220209 6 FTP RJ45-6-F Shielded RJ45plug 23&26 AWG
10/1200
Code Reference Description Packaging
2220306 HT3 Tool to crimp RJ45 connectors
1
Articles chart for RJ45 connector
Articles chart for RJ45 protector
Code Reference Description Packaging
2220210 RJBT-WH Color protector for RJ45 white 25/1400
2220212 RJBT-BK Color protector for RJ45 black 25/1400
2220214 RJBT-YL Color protector for RJ45 yellow 25/1400
2220216 RJBT-RD Color protector for RJ45 red 25/1400
2220218 RJBT-BL Color protector for RJ45 blue 25/1400
2220220 RJBT-GN Color protector for RJ45 green 25/1400
2220222 RJBT-GY Color protector for RJ45 grey 25/1400
2220224 RJBT-MC Color protector for RJ45 multicolor 25/1400
Structured cabling
Networks
10. / Infrastructure for data networks
1 9 ” P AT C H P A N E L S
19” patch panelsAll the input and output lines of the Net-work devices go through a connection panel that makes easier the management and modification of the installation. This also reduces usage of female RJ45 con-nector which are integrated in active de-vices. These connectors are often difficult to replace.
Wide offerFte Networks has a wide range of patch panels suited to any installation requirement.
From the classic pre-connected panels, up to the new concept of modularity. In the new modular panel, several technologies (category 5e and category 6, shielded or unshielded) can be installed, even different materials in a near future, including optical fiber. This is possible thanks to the empty panels and the 180º keystone jacks that Fte Networks has in its catalogue.
Enlargement of the installationThe modular panels allow the installation to expand as it needs.The installer only has to install what is required at anytime. It is possible to cover holes until needed.
Back supportThe new modular panel can be complemented by a back support for a better organization and layout of the wiring.
Structured cabling
Networks
Infrastructure for data networks / .11
1 9 ” P AT C H P A N E L S
Articles chart for loaded patch panels
Code Category Reference Description
2220280 5e UTP PPC-5e-U-12 Patch panel 19” not shielded 12 ports 1
2220282 5e UTP PPC-5e-U-24 Patch panel 19” not shielded 24 ports 1
2220284 5e UTP PPC-5e-U-48 Patch panel 19” not shielded 48 ports 1
Code Category Reference Description
2220286 6 UTP PPC-6-U-12 Patch panel 19” not shielded 12 ports 1
2220288 6 UTP PPC-6-U-24 Patch panel 19” not shielded 24 ports 1
2220290 6 UTP PPC-6-U-48 Patch panel 19” not shielded 48 ports 1
Code Category Reference Description Packaging
2220293 5e-6UTP-FTP
PPC-U/F Unloaded unshielded 24 ports 19”patch panel
1
2220295 - PPC-BK* Bracket for unloaded 24 ports 19”patch panel
1
Articles chart for unloaded patch panels
NOTE: the compatible keystone jacks for this patch panel are KJR-5e-U-WH, KJR-6-U-WH, KJR-6-F-SI, KJR-6A-F-SI (see page 07)
*(Bracket essential in FTP installations)
Code Category Reference Description Packaging
2220294 6A FTP PPC-6A-F-24 19” patch panel shielded 24 ports, cat. 6A
1
Code Category Description Packaging
0705258 PK Insertion plastic knife 1
Packaging
Packaging
Structured cabling12. / Infrastructure for data networks
T E L E C O M M U N I CAT I O N O U T L E T S
Articles chart for Telecommunication outlets
Code Reference Description Packaging
2220262 SMB-1-WH Unloaded surface mount box single port
1/80
2220264 SMB-2-WH Unloaded surface mount box dual ports
1/40
Code Reference Description Packaging
2220250 SMB-5e-U-1-WH Wall outlet RJ45individual Cat. 5e
1/10
2220252 SMB-5e-U-2-WH Wall outlet RJ45twin Cat. 5e
1/10
Telecommunicat ion out letsThe connection between the computer or the data network equipments and the net is usual ly made thought a f ixed element on the wal l . This element const i tutes the f inal point of permanent data network. I t is one of references when cert i fy ing the instal lat ion.
It includes everything we needThe telecommunication outlets without connector include the necessary elements in order to make the installation easier: bridles and screws.
Versatile and efectiveKeystone jack from any technology (category 5e, category 6, shielded as well as unshielded) can be installed inside the empty telecommunication outlets. The connectors that should be used are the 90º models or the tooless keystone jacks.
Networks
Structured cabling Infrastructure for data networks / .017
C O N E C T O R E SNetworks
Cabinets
Server cabinet
Multipurpose cabinet
Wall cabinet
Accessories
Telecommunication cabinet kits
Networks
Cabinets
C A B I N E T S
14. / Infrastructure for data networks
Articles chart for server cabinet
Code Reference Description Dimension*
0050940 SER 61022 Server Cabinet 22U 600x1000x1200 mm
0050942 SER 61042 Server Cabinet 42U 600x1000x2000 mm
0050944 SER 61047 Server Cabinet 47U 600x1000x2200 mm
0050946 SER 81042 Server Cabinet 42U 800x1000x2000 mm
0050948 SER 81047 Server Cabinet 47U 800x1000x2200 mm
Server cabinetServers and network devices often have special requirement for weights and heat dissipation. The strong structure and wide ventilation areas in the pont and rear back doors of the Fte Networks server cabinets are perfect for this purpose.
If other measures or configurations are required, ask Fte maximal*(Width x Depth x Height)
Static load up to 1.000 Kg
According to standards ASI/EIA RS-310-D, IEC297-2,DIN41491 part 1; DIN41494 part 7, GB/T3047.2-92 standard,ETSI standard compatible
Single opened ambossed front door(ventilated area up to 65%)
Side panels with fasten opened bolt
Fast adjustment feet
130º opening door
The depth is adjustable (take 25MM as unit), the height of capacity is adjustable (take 1U as unit)
Material: cold rolled steel, 2mm thickness frame
Color: black RAL9004 in stock, grey RAL7044 on request
Accesories included: 40 sets M6 screws and nuts,4 elevation feet, 4 heavy duty castors
Top cover with the pasticcover entry
Foam glue and side mounting angle
Mounting profile with unit markand 130 degree hinge
Networks
Cabinets
C A B I N E T S
Infrastructure for data networks / .15
Articles chart for Multipurpose Cabinet
Mult ipurpose cabinetFor data distribution equipment, such as switches and patch panels, the multiple purpose cabinet is the perfect solution. Available in a variety of dimen-sions, it has a capacity up to 500 kilos, which makes it suitable for a wide range of applications.
Code Reference Description Dimension*
0050950 MUL 6622i Multipurpose Cabinet 22U 600x600x1200 mm
0050952 MUL 6632i Multipurpose Cabinet 32U 600x600x1600 mm
0050954 MUL 6642i Multipurpose Cabinet 42U 600x600x2000 mm
0050956 MUL 6922i Multipurpose Cabinet 22U 600x900x1200 mm
0050958 MUL 6932i Multipurpose Cabinet 32U 600x900x1600 mm
0050960 MUL 6942i Multipurpose Cabinet 42U 600x900x2000 mm
0050962 MUL 8842i Multipurpose Cabinet 42U 800x800x2000 mm
Static load up to 500 Kg
According to standards ASI/EIA RS-310-D, IEC297-2,DIN41491part 1; DIN41494 part 7, GB/T3047.2-92standard, ETSI standard compatible
Glass front door, single fl at steel rear door
Side panels with fasten opened bolt
Fast adjustment feet
Material: cold rolled steel, 2mm thickness frame
Color: black RAL9004 in stoc, grey RAL7044 on request
Accesories included: top cover fan, 3 fi xed shelfs,40 sets M6 screws and nuts, 4 elevation feet,4 heavy duty castors
NOTE: References for assembled version:MUL XXXXiReferences for disassembled version:MUL XXXXo(see articles chart page 24)
If other measures or configurations are required, ask Fte maximal*(Width x Depth x Height)
Networks
Cabinets
C A B I N E T S
16. / Infrastructure for data networks
Code Reference Description Dimension*
0051014 WDB 666 Wall CabinetDouble section 6U
600x600x368 mm
0051016 WDB 669 Wall CabinetDouble section 9U
600x600x501 mm
0051018 WDB 6612 Wall CabinetDouble section 12U
600x600x635 mm
0051020 WDB 6615 Wall CabinetDouble section 15U
600x600x769 mm
0051022 WDB 6618 Wall CabinetDouble section 18U
600x600x901 mm
Code Reference Description Dimension*
0051002 WSB 646i Wall CabinetSingle section 6U
600x450x368 mm
0051004 WSB 649i Wall CabinetSingle section 9U
600x450x501 mm
0051006 WSB 6412i Wall CabinetSingle section 12U
600x450x635 mm
0051008 WSB 6415i Wall CabinetSingle section 15U
600x450x769 mm
0051010 WSB 6418i Wall CabinetSingle section 18U
600x450x901 mm
0051012 WSB 6422i Wall CabinetSingle section 22U
600x450x1068 mm
Articles chart for single section wall cabinets
Articles chart for double section wall cabinets
Wall cabinetsIt is perfect for small installations and offices,suitable also for TV signal reception systems and distribution devices from Fte Networks.
Static load up to 60 Kg
According to standards ASI/EIA RS-310-D,IEC297-2, DIN41491 part 1; DIN41494 part 7,GB/T3047.2-92 standard, ETSI standard compatible
Glass front door, single fl at steel rear door180º front door openning
Side panels with fasten opened bolt
Material: cold rolled steel, 2mm thickness frame
Color: black RAL9004 in stock, grey RAL7044 onrequest
Accessories included: 10 sets screws and nuts in6u to 12u cabinets and 20 sets screws in 15u to22u cabinets.
Static load up to 60 Kg
According to standards ASI/EIA RS-310-D,IEC297-2, DIN41491 part 1; DIN41494 part 7,GB/T3047.2-92 standard, ETSI standard compatible
Double section body, the main can be opennedup to 120º
Glass front door, single fl at steel rear door
180º front door openning
Side panels with fasten opened bolt
Color: black RAL9004 in stock, grey RAL7044 onrequest
Accesories included: 10 sets screws and nuts in6u to 12u cabinets and 20 sets screws in 15u to22u cabinets.
If other measures or configurations are required, ask Fte maximal*(Width x Depth x Height)
If other measures or configurations are required, ask *(Width x Depth x Height)
Networks
Cabinets
C A B I N E T S
Infrastructure for data networks / .17
AccessoriesA wide range of accessories are available for 19” cabinets from Fte Networks. This pro-vides a complete solution for an organized and effective installation.
Articles chart for accessories
Code Reference Description
2220310 PH 1T Cable manager with cover 1U
2220312 PH 1S Cable manager 19” without cover 1U
2220314 BRK 30 Fixed shelf, 30 cm, 2U
2220316 BRK 40 Fixed shelf, 40 cm, 2U
0051046 BRK EX 60 Removable shelf 600 mm
0051054 BRK EX 80 Removable shelf 800 mm
0051056 BRK EX 90 Removable shelf 900 mm
0051050 BRK EX D60 Double removable shelf 600 mm
0051058 BRK EX D80 Double removable shelf 800 mm
0051060 BRK EX D90 Double removable shelf 900 mm
0051048 BRK F 60 Heavy load sliding self, 600 mm
0051062 BRK F 80 Heavy load sliding self, 800 mm
0051064 BRK F 90 Heavy load sliding self, 900 mm
2220320 BER 8ALS Aluminum multi-socket 19” withon/off switch
2220318 CTTR 24 Set screws and nuts
0050917 VNT Cooling fan (unit)
0051052 TERM DIG Digital temperature unit
0051032 ELEV SET Elevation set (4 feet + 4 wheels)
0051034 TP 1U Metal cover 1U
0051036 TP 2U Metal cover 2U
0051038 TP 3U Metal cover 3U
0051040 TP 4U Metal cover 4U
0051042 ESC RACK Brush panel
0051044 GC RACK Cable ring
0051078 IGCK Individual grounding connection kit
BER8ALS
GCRACK
PH1T PH1S
BRK40
BRKF60BRKEXD60
BRKEX60
ESCRACKESCRACK
TP4UVNT
ELEVSETCTTR24
TERMDIG
IGCK
Networks
Cabinets
C A B I N E T S
18. / Infrastructure for data networks
Telecommunication cabinet kits
CATEGORY 5e CATEGORY 6
9U cabinet, 450 mm24 ports patch panelCable manager without coverFixed shelfAluminum multi-socket24 Patch cords 1 m
9U cabinet, 450 mm24 ports patch panelCable manager without coverFixed shelfAluminum multi-socket24 Patch cords 1 m
15U cabinet, 450 mm48 ports patch panelCable manager without coverFixed shelfAluminum multi-socket48 Patch cords 1 m
15U cabinet, 450 mm48 ports patch panelCable manager without coverFixed shelfAluminum multi-socket48 Patch cords 1 m
6U cabinet, 450 mm12 ports patch panelCable manager without coverAluminum multi-socket12 Patch cords 1 m
6U cabinet, 450 mm12 ports patch panelCable manager without coverAluminum multi-socket12 Patch cords 1 m
K48P-5e: 48 ports cabinet kitCode: 0051066
K24P-5e: 24 ports cabinet kitCode: 0051068
K12P-5e: 12 ports cabinet kitCode: 0051070
K48P-6: 48 ports cabinet kitCode: 0051072
K24P-6: 24 ports cabinet kitCode: 0051074
K12P-6: 12 ports cabinet kitCode: 0051076
Fte Networks has created the fol lowing kits for an easier select ion of material .
The instal ler can request al l the elements included in one kit just giv ing the code for the kit needed.
NOTE: The products included in the kit are supplied disassembled.
Networks
Power Distribution Units (PDU)Due to the electrical supplying of the active devi-ces in a network, the cabinets must use an element known as PDU: A device that centralizes and makes the electrical distribution in the cabinet easier.Nowadays the computing services are beco-ming more and more professional and communica-tion systems have to guarantee a non stop service, therefore the PDU takes on a higher relevance by offering different setting up, which provides higher control and information over the installation.
Power Distribution Units20. / Infrastructure for data networks
P O W E R D I S T R I B U T I O N U N I T S
For all levelsFrom the simplest installations up to the most sophisticated ones, there is a PDU suitable for each need.
Setting upFte Networks has a stock of articles that covers the most of the applications. Besides, there are a lot of possible settings up according to the demands of the projects with specifics needs: kind of socket, length of the input cable, power available, vertical/horizontal layout, etc.
Please contact to Fte Networks for further information about terms and conditions.
RegulationAll the PDUs of Fte Networks obey the mechanical and electrical requirements that the current law demands. The high quality materials as well as the used inner connections, make PDUs Fte Networks lasting and secure devices.
Great powerThere is a high number of settings up adapted up to 32A power with section of input cable of 6mm2 for the cabinets that hold devices with high consumption.
Networks
Power Distribution Units Infrastructure for data networks / .21
P O W E R D I S T R I B U T I O N U N I T S
Code Reference Description
0052000 BA 6 AMP Basic PDU, 16A, 6xDIN49440+ ammeter
0052002 BA 8 SV Basic PDU, 16A, 8xDIN49440+ surge protection
0052004 BA 6 MG Basic PDU, 16A, 6xDIN49440+ circuit breaker
0052006 BA 8 FL Basic PDU, 16A, 8xDIN49440+ fuse+light indicator
0052008 BA 10 FL PDU Basic, 16A, 10xIEC320 C13+ fuse+light indicator
0052010 BA 10 SW PDU Basic, 16A, 10xIEC320 C13+ circuit breaker
Articles chart for Basic series
“Anti disconnection” designIn order to solve the problem of the easy disconnection of the computing outlet IEC320 C14 in applications with a high wiring density, we have designed an easy and useful system that avoids it.
Count on the necessary outletsThe small size of the IEC320 C14 outlet, compared to other out-lets of regular usage, allows having a higher number of devices being fed from the same PDU.
We must keep always in mind the maximum nominal electricity that can run through the device.
Basic ser iesThe basic ser ies of Fte Networks incor-porate, over the tradit ional power distr i -but ion units, mult iple funct ional i t ies for the supervision of the consumption and protect ion, very useful for those insta-l lat ions that have more advanced needs than the tradit ional ones.
Networks
22. / Infrastructure for data networks Power Distribution Units
P O W E R D I S T R I B U T I O N U N I T S
Code Reference Description
0052100 VE G 16-1 Vertical PDU, 6 slots guide, 16A, single input
0052102 VE G32-1 Vertical PDU, 6 slots guide, 32A, single input
0052104 VE G16-2 Vertical PDU, 6 slots guide, 16A, double input
0052106 VE G32-2 Vertical PDU, 6 slots guide, 32A, double input
0052108 VE MC13-5 Vertical PDU, 5xIEC320 C13 socket module
0052110 VE MC19-4 Vertical PDU, 4xIEC320 C19 socket module
0052112 VE MSCHUKO-4 Vertical PDU, 4xDIN49440 socket module
Articles chart for Vertical series
Vert ical ser iesThe vert ical devices series are perfect for sett ing a modular and versat i le instal lat ion. The number of power out lets instal led could grow according to the growing of the instal lat ion without the need of switching off any device thanks to i ts guides and the modular basis system, which al low “hot-swap” connection.
Redundant power supplyThe Vertical series allows the installation to get the power from two different power lines. So, there will be just one power supply distributor in the cabinet, which ensures the electrical supply redundancy to the active devices in the data network.
Also, it allows balancing the charges very easily: we only have to turn upside down the modular base.
High number of outputsThe vertical series consist in a device that is designed in order to allow the electrical connection to a high number of devices. The size of the main guide restricts its usage to cabinets with a height of 42U and 47U.
L1
L2
Networks
Infrastructure for data networks / .23 Power Distribution Units
P O W E R D I S T R I B U T I O N U N I T S
Code Reference Description
0052200 RE A8-16 A level, 16A, 8xIEC320 C13 sockets
0052202 RE B8-16 B level, 16A, 8xIEC320 C13 sockets
0052204 RE C8-16 C level, 16A, 8xIEC320 C13 sockets
0052206 RE D8-16 D level, 16A, 8xIEC320 C13 sockets
0052208 RE D14-32 D level, 32A, 8xIEC320 C13 sockets, 4xIEC320 C19 sockets
0052280 RE T/H T/H sensor
0052282 RE S Smoke sensor
0052284 RE W Water sensor
0052286 RE D Door sensor
Articles chart for Remote series
Remote seriesIt is the most sophist icated series of the PDUs of Fte Networks. There are dif ferent set ups and monitor ing and control opt ions, so we can reach an indiv idual control and monitor ing for each one of the power outputs, sett ing the maximums and minimums for the alarm levels and sett ing up the sending of warnings.
Integration possibilitiesInformation Exchange capacity in protocol SNMPv2.
This protocol allows the control of the remote PDU unit to be done through IT software system.
SNMPv2
Remote management software
Features A B C D
Measurement of total consumption Measurement of individual consumption State monitoring for each ON/OFF State monitoring, sensors Alarms for total power limits Alarms for individual power limits Alarms for temperature/humidity limits
Control levels
Networks
Index of references24. / Infrastructure for data networks
I N D E X O F R E F E R E N C E S
Index of references
Code Reference Page
0052000 BA 6 AMP 21
0052002 BA 8 SV 21
0052004 BA 6 MG 21
0052006 BA 8 FL 21
0052008 BA 10 FL 21
0052010 BA 10 SW 21
2220320 BER 8 ALS 17
2220314 BRK 30 17
2220316 BRK 40 17
0051046 BRK EX 60 17
0051054 BRK EX 80 17
0051056 BRK EX 90 17
0051050 BRK EX D60 17
0051058 BRK EX D80 17
0051060 BRK EX D90 17
0051048 BRK F 60 17
0051062 BRK F 80 17
0051064 BRK F 90 17
2220300 CA-5E-U-1000FT-GY 03
2220305 CA-6-F-1000FT-LSZH-GY 03
2220307 CA-6A-SF-1000FT-LSZH-GY 03
2220302 CA-6-U-1000FT-GY 03
2220304 CA-6-U-1000FT-LSZH-GY 03
2220309 CA-7-SF-1000FT-LSZH-GY 03
2220228 CCS-BK 05
2220234 CCS-BL 05
2220236 CCS-GN 05
2220238 CCS-MC 05
2220232 CCS-RD 05
2220226 CCS-WH 05
2220230 CCS-YL 05
2220318 CTTR 24 17
0051032 ELEV SET 17
0051042 ESC RACK 17
0051044 GC RACK 17
0705250 HT 07
2220306 HT3 09
0051078 IGCK 17
0051066 K 48P-5e 18
0051068 K 24P-5e 18
Code Reference Page
0051070 K 12P-5e 18
0051072 K 48P-6 18
0051074 K 24P-6 18
0051076 K 12P-6 18
2220202 KJK-5e-U-WH 07
2220296 KJK-6-F-SI 07
2220201 KJR-5e-U-WH 07
2220297 KJR-6-F-SI 07
2220205 KJR-6A-F-SI 07
2220299 KJR-6-U-WH 07
2220200 KJT-5e-U-WH 07
2220204 KJT-6-U-WH 07
0050950 MUL 6622i 15
0050970 MUL 6622o 15
0050952 MUL 6632i 15
0050972 MUL 6632o 15
0050954 MUL 6642i 15
0050974 MUL 6642o 15
0050956 MUL 6922i 15
0050976 MUL 6922o 15
0050958 MUL 6932i 15
0050978 MUL 6932o 15
0050960 MUL 6942i 15
0050980 MUL 6942o 15
0050962 MUL 8842i 15
0050982 MUL 8842o 15
2220010 PC-5e-U-MT-0.5GY 05
2220013 PC-5e-U-MT-1.5GY 05
2220195 PC-5e-U-MT-10GY 05
2220196 PC-5e-U-MT-15GY 05
2220012 PC-5e-U-MT-1GY 05
2220014 PC-5e-U-MT-2GY 05
2220016 PC-5e-U-MT-3GY 05
2220018 PC-5e-U-MT-5GY 05
2220194 PC-5e-U-MT-7.5GY 05
2220150 PC-6-F-MT-0.5GY 05
2220153 PC-6-F-MT-1.5GY 05
2220192 PC-6-F-MT-10GY 05
2220193 PC-6-F-MT-15GY 05
Networks
Infrastructure for data networks / .25 Index of references
I N D E X O F R E F E R E N C E S
Index of references
Code Reference Page
2220152 PC-6-F-MT-1GY 05
2220154 PC-6-F-MT-2GY 05
2220156 PC-6-F-MT-3GY 05
2220158 PC-6-F-MT-5GY 05
2220191 PC-6-F-MT-7.5GY 05
2220080 PC-6-U-MT-0.5GY 05
2220083 PC-6-U-MT-1.5GY 05
2220189 PC-6-U-MT-10GY 05
2220190 PC-6-U-MT-15GY 05
2220082 PC-6-U-MT-1GY 05
2220084 PC-6-U-MT-2GY 05
2220086 PC-6-U-MT-3GY 05
2220088 PC-6-U-MT-5GY 05
2220188 PC-6-U-MT-7.5GY 05
2220312 PH 1S 17
2220310 PH 1T 17
0705258 PK 11
2220280 PPC-5e-U-12 11
2220282 PPC-5e-U-24 11
2220284 PPC-5e-U-48 11
2220286 PPC-6-U-12 11
2220288 PPC-6-U-24 11
2220290 PPC-6-U-48 11
2220294 PPC-6A-F-24 11
2220295 PPC-BK 11
2220293 PPC-U/F 11
0052200 RE A8-16 23
0052202 RE B8-16 23
0052204 RE C8-16 23
0052206 RE D8-16 23
0052208 RE D14-32 23
0052280 RE T/H 23
0052282 RE S 23
0052284 RE W 23
0052286 RE D 23
2220208 RJ45-5e-U 09
2220209 RJ45-6-F 09
2220207 RJ45-6-U 09
2220212 RJBT-BK 09
2220218 RJBT-BL 09
Code Reference Page
2220220 RJBT-GN 09
2220222 RJBT-GY 09
2220224 RJBT-MC 09
2220216 RJBT-RD 09
2220210 RJBT-WH 09
2220214 RJBT-YL 09
0050940 SER 61022 14
0050942 SER 61042 14
0050944 SER 61047 14
0050946 SER 81042 14
0050948 SER 81047 14
2220262 SMB-1-WH 12
2220264 SMB-2-WH 12
2220250 SMB-5e-U-1-WH 12
2220252 SMB-5e-U-2-WH 12
0051052 TERM DIG 17
0051034 TP 1U 17
0051036 TP 2U 17
0051038 TP 3U 17
0051040 TP 4U 17
0052100 VE G16-1 22
0052102 VE G32-1 22
0052104 VE G16-2 22
0052106 VE G32-2 22
0052108 VE MC13-5 22
0052110 VE MC19-4 22
0052112 VE MSCHUKO-4 22
0050917 VNT 17
0051018 WDB 6612 16
0051020 WDB 6615 16
0051022 WDB 6618 16
0051014 WDB 666 16
0051016 WDB 669 16
0051006 WSB 6412i 16
0051008 WSB 6415i 16
0051010 WSB 6418i 16
0051012 WSB 6422i 16
0051002 WSB 646i 16
0051004 WSB 649i 16
BCN Distribuciones, S.A.U.Mogoda,110Pol. Industrial Can Salvatella08210 Barberà del Vallès (Barcelona)Tel. +34 93 729 27 00Fax +34 93 729 30 [email protected]
+ info: networks.ftemaximal.com
FRANCE16 ZAE Les Mouilles74570 GroisyTel. 04 50 68 80 17Fax. 04 50 68 84 [email protected]
DEUTSCHLANDAuf der Höhe 8D-44536 LünenTel.: +49 231 8785 01Fax: +49 231 8785 [email protected]
SUBSIDIARIES
ITALIAVia Edison, 2942040 Calerno di Sant’Ilario d’Enza (RE)Tel. 0522 909701Fax. 0522 [email protected]
UNITED ARAB EMIRATESP.O. Box. 262442Jebel Ali Free ZoneWarehouse FZS5AB03DubaiTel. 00 971 4 886 5700Fax. 00 971 4 886 5701www.ftemaximal.ae
PORTUGALRua José Carlos Ary dos SantosA-das-Lebres (Loures)2670-791 Santo Antão do TojalTel. 21.983.87.00 Fax. [email protected]
Lega
l Dep
osit:
M
NN
ET1
1EN
.0 J
une
11