BOQ MEP FINAL.xls

23
NAGA Architects Designers Planners Dubai Atlanta Alexandria Amsterdam Issue for Tender Rev (0) DXB 06-13 Lotus Hotel BOQ Section 01200 - BOQ Page 37 of 37 Item Description Unit Qty Unit Price Division 15 - Mechanical AIR CONDITIONING SERVICES 15.1 Nos. 8 15.2 Nos. 3 15.3 Item 15.4 Nos. 185 15.5 Nos. 1 15.6 Nos. 1 15.7 Item 15.8 Volume control dampers at all branches. Item 15.9 FANS No. 15.9.1 No. 5 15.9.2 No. 5 15.9.3 Kitchen makeup air fans with filters as specified. No. 4 15.9.4 Upblast fans as shown on the drawing and as specified No. 7 15.9.5 No. 3 15.9.6 No. 2 15.1 No. 2 15.11 Window A/Cs (Drip free type) Nos. 1 15.12 Chillers, screw compressors as specified. (25 tons each) Nos. 3 15.13 Item 4 15.14 Item 3 15.15 Item LS 15.16 Pump control panel Item LS Total Amount secondarydesign, supply, installation, testing commissioning, warranty &maintenance of the following works. Where quantities have not beenincluded , the contractor shall indicate the quantities as per his own take off from the Tender document. Air Handling Units complete with all connections, valves, filters, accessories and fittings, as per Schedule in Particular specifications. valves, filters, heat exchangers, heat pipes, electrical heaters, accessories and fittings as per Particular Specification. including all control valves, sensors motorised dampers, motorised valves, DDC controls, MCC's etc. complete as detailed in "Schedule of Controls"of the Particular Specifications. Fan coil units completed with all connections, valves, secondary drain apns, etc. as per "Schedule of Fan Coil Units"of the Particular Specifications. Fan Coil units (dual coil) for ICUs and recovery rooms with standby DX condensing units including refrigerant piping and all accessories as specified in particular specifications. Close circuit unit and MDF rooms with standby DX coil and condensing unit including refrigerant piping and accessories as specified in particular specifications. Fire dampers with access panels in ducts at all duct entry & exits from plant rooms as well as fire wells/zones and motorized fire dampers and motorized Basement ventilation and exhaust fans complete with required controls and accessories as specified. Extract air fans with motorized volume control damper as shown in drawings and relevant controls as specified. Pressurization fans with chilled water coil and VFD with associated controls as specified. Smoke extract air fans with associated controls as specified. Condensing units with refrigerant piping and all necessary controls and accessories for operation theatre Air Handling Units. 3 duty/1 standby CHW primary pumps complete with all connections, valves, test points, gauges, header and fittings and controls. 2 duty/1 standby CHW secondary pumps with VFDs complete all connections, valves, test point, gauges, header and fittings and controls. Chilled water pressurization unit set complete with pumps,pressurization vessel, connections, valves and control panels.

Transcript of BOQ MEP FINAL.xls

DXB-02-19ItemDescriptionUnitQtyUnit PriceTotal AmountDivision 15 - MechanicalAIR CONDITIONING SERVICESUnless otherwise stated, the work shall pertain to the secondarydesign, supply, installation, testing commissioning, warranty &maintenance of the following works. Where quantities have not beenincluded , the contractor shall indicate the quantities as per his own take off from the Tender document.15.1Air Handling Units complete with all connections, valves, filters, accessories and fittings, as per Schedule in Particular specifications.Nos.815.2Fresh air handling units completed with all connections, valves, filters, heat exchangers, heat pipes, electrical heaters, accessories and fittings as per Particular Specification.Nos.315.3Control system for the Air Conditioning system, including all control valves, sensors motorised dampers, motorised valves, DDC controls, MCC's etc. complete as detailed in "Schedule of Controls"of the Particular Specifications.Item15.4Fan coil units completed with all connections, valves, secondary drain apns, etc. as per "Schedule of Fan Coil Units"of the Particular Specifications.Nos.18515.5Fan Coil units (dual coil) for ICUs and recovery rooms with standby DX condensing units including refrigerant piping and all accessories as specified in particular specifications.Nos.115.6Close circuit unit and MDF rooms with standby DX coil and condensing unit including refrigerant piping and accessories as specified in particular specifications.Nos.115.7Fire dampers with access panels in ducts at all duct entry & exits from plant rooms as well as fire wells/zones and motorized fire dampers and motorized smoke dampers as shown on drawing.Item15.8Volume control dampers at all branches.Item15.9FANSNo.15.9.1Basement ventilation and exhaust fans complete with required controls and accessories as specified.No.515.9.2Extract air fans with motorized volume control damper as shown in drawings and relevant controls as specified.No.515.9.3Kitchen makeup air fans with filters as specified.No.415.9.4Upblast fans as shown on the drawing and as specifiedNo.715.9.5Pressurization fans with chilled water coil and VFD with associated controls as specified.No.315.9.6Smoke extract air fans with associated controls as specified.No.215.1Condensing units with refrigerant piping and all necessary controls and accessories for operation theatre Air Handling Units.No.215.11Window A/Cs (Drip free type)Nos.115.12Chillers, screw compressors as specified. (25 tons each)Nos.315.133 duty/1 standby CHW primary pumps complete with all connections, valves, test points, gauges, header and fittings and controls.Item415.142 duty/1 standby CHW secondary pumps with VFDs complete all connections, valves, test point, gauges, header and fittings and controls.Item315.15Chilled water pressurization unit set complete with pumps,pressurization vessel, connections, valves and control panels.ItemLS15.16Pump control panelItemLSTotal Amount of PageCont. Division 15 - Mechanical15.17Manual chemical dosing potItemLS15.18Smoke extract system complete with smoke extract fans, smoke curtain and powered ventilator interfaces with building FA system as specified.ItemLS15.19Chilled water piping with insulation and all accessories including isolating valves on supply & balancing valve on return, all as specified, with hangers, support, fittings etc 300mm dia pipe.15.19.1200mm dia pipeMLS15.19.2150mm dia pipeMLS15.19.3125mm dia pipeMLS15.19.4100mm dia pipeMLS15.19.580mm dia pipeMLS15.19.665mm dia pipeMLS15.19.750mm dia pipeMLS15.19.840mm dia pipeMLS15.19.932mm dia pipeMLS15.19.1025mm dia pipeMLS15.19.1120mm dia pipeMLS15.19.1215mm dia pipeMLS15.19.13Isolating valve & balancing valves at all branches from main lineItemLS15.20Sheet metal ductwork including accessories (dampers, splitters, flexible ducts, plenum boxes) and fittings complete with insulation as detailed on drawings,M25100Grilles/Diffusers as per drawings including:15.20.1* Ceiling diffusers in areas with false ceilingItem15.20.2* Linear slot diffusers for front of house corridorsItem15.20.3* Sidewall grilles and registersItem15.20.4* External louvers including sand trap louversItemLS15.20.5* 600 x 600 Egg crate grilleItem815.21Sound attenuators for supply, extract & return air systems ductwork as required to maintain specified NC level within all conditioned spaces.ItemDoor louvres as required & where shown on drawingsItem150Noise and vibration control for the following equipment including inertia basis, vibration isolators, flexible connectors etc forItemLS* Air Handling Units* Chilled water pumps* Chillers* Fire pumps15.22Condensate drain piping for AHUs, FCUs and other A/C equipment as requiredItemLS15.23Improving of power factor for all HVAC equipment and provision of UV relays/timers as per DEWA requirements (if not corrected at MDB)ItemLS15.243rd party air balancing, chilled water balancing, testing & commissioning of all HVAC plant, equipment & systemsItemLS15.25Chemical treatment of chilled water system including initial supply of chemicals for warranty/maintenance period & manual chemical dosing systemItemLS15.26DDC controls & thermostats including BMS system as specified, complete with required I/O's.ItemLS15.27Spare set of filters (one complete set off all filters to be handed over after commissioning). The spare set to be used to exchange installed temporary throw away filters during installation.ItemLS15.28Cutting, patching and other civil works related to MEP worksItemLS15.29Scaffolding, hangers to support required for work execution.ItemLSTotal Amount of PageCont. Division 15 - Mechanical15.30List of spare parts, Client operator training, as built drawings, O & M manuals, schematics, shop drawings and other such fabrication & close-out documentation required by Client/Engineer.ItemLSAdditional Items15.31The Tenderer is to attach this bill of quantities any additional items with quantities, enumerated or itemised and rates which are not previously included to complete the build-up of the lump sum tender price for this section of the works. Should the Tenderer fail to insert any items here, it will be deemed that his lump sum price for the tender includes all items either shown on the drawings and described in the specification or deemed necessary by the Tenderer to develop the drawings and specification to represent the entire cost of the works and no subsequent claim for any additional item will be entertained.`Total Amount of PageDivision 15 - MechanicalTotal of HVAC SystemPage 1Page 2Page 3Page 4Total Amount of DivisionWATER SERVICES15.32Unless otherwise stated, the work shall pertain to the secondary design, supply, installation, testing, commissioning, warranty & maintenance of the following works. Where quantities have not been included, the contractor shall indicate the quantities as per his own take-offs from the Tender document.15.32.1Incoming water supply connection to provisions made available in plant room, as shown on drawing W-01.Item15.33Gas fired central water heaters as per "Schedule of Water Heaters of the Particular Specification complete with interconnecting valves, fitting and accessories.Nos.415.34Installation of sanitary fixtures, complete with all fittings, trim, accessories as stated. Contractor to include for final flex connection, angle CP vlaves, waste connections (where exposed etc. all as per specification requirements).ItemL/S15.35Hose bibs with integral vacuum breaker & hose end adaptorNo.15.36Domestic Water distribution pipework complete with insulation fittings, valves, supports and accessories as per Specifications and drawings.15.36.1Domestic cold water pipework complete with fittings, valves supports and accessories as per Specifications and drawings.Item15.36.2Domestic cold water & hot water PEX piping within toilets & kitchens complete with valves, distribution boxes, headers/manifold etc.Item15.37Cold water with shut off valve (Basement)Item15.38Disinfection of complete water supply system15.39Transfer water pumps complete with all valvesNos.215.428 C Booster pumps (1 duty/1 standby assist/ 1 jockey) complete with all valves, test points, headers, pressure gauges, pipe work, fittings, VCDs, VFD and accessories including pressure vessel as specified.Nos.315.41CWS Booster pumps (1 duty/1 standby assist/1 jockey) complete with all valves, test points, headers, pressure gauges, pipe work, fittings, VCDs, VFD and accessories including pressure vessel as specified.Nos.315.42Hot water recirculation pump set (1 run/1 standby) with valves and accessories and controls115.44Pump control panels.item15.45Heat exchanger for 28C water storage for 28C water supply ass per specificationsNo.115.46Heat exchanger for 10C water supply as per specificationsNo.115.47Panel type water tanks 3 x 1.5 x 2.5mH for normal water storage including all connections and accessories as per specifications.Nos.115.48Panel type insulated water tank 3 x 1.5 x 2.5mH for 28C water storage including all connections and accessories as per specificationsNos.1Total Amount of PageDivision 15 - Mechanical15.49All shop drawings & close-out documentation including As-built drawings, O & M manuals, schematic charts, etc.Item15.5Additional Items15.51The Tenderer is to attach with this bill of quantities any quantities items with quantities, enumerated or itemised and rates which are not previously included to completethe build-up of the lump-sum tender price for this section of the works. Should the Tenderer fail to insert any items here, it will be deemed that his lump sum price for the tender includes all items either shown on the drawings and described in the specification to represent the entire cost of the works and no subsequent claim for any additional item will be entertained.Total Amount of PageDivision 15 - MechanicalWATER SERVICESTotal of Water ServicesPage 1Page 2Page 3Page 4Page 5Page 6Total Amount of PageDivision 15 - MechanicalDRAINAGE SERVICES15.52Unless otherwise stated, the work shall pertain to the secondary design, supply, installation, testing, commissioning, warranty & maintenance of the following works. Where quantities have not been included, the contractor shall indicate the quantities as per his own take-offs from the Tender document:15.53Floor drains/clean outs/rain water outletNo.15.53.1RWONo.515.53.2FD-K in kitchenNo.3715.53.3FD-K 1No.1115.53.4FD-P - Plant roomsNo.1415.53.5FD-G - Garbaage roomNo.215.53.6FD in toiletsNo.2015.53.7FD-TD Terrace DrainNo.3715.53.8FTNo.12815.53.9WCO with stainless steel access coverNo.15.53.10FCO with stainless steel access cover at floor deck.No.115.53.11GT --Gulley TrapNo.215.53.12Manhole frames & cover for all manholes,external valve pits, gulley traps, etc. (Civil work only by others)Item215.53.13Condensate drain pipes complete with all fittings 19mm closed cell, insulation with protective covering, accessories and supportsItem15.53.14CB-Catch Basin (Basement-3)Item415.53.15CB-01 (Basements 1 & 2)Item315.53.16Grease Trap - Type 'B"No.115.53.17Oil interceptorNo.115.53.18Stop log for underground water tankNo.115.54Drainage piping, fitting and accessories, all as per drawings & specifications in vertical & horizontal runsItem15.55Acoustic lagging for all horizontal runs of DEWAge lines above occupied spaces as specified.ItemL/S15.56Sanitary drainage connections, soil waste & vest including final connections to fixtures and stacks & horizontal runs at low and high level were shown for all saanitary fixtures:Item15.57MH vents pipeItem15.582 Nos. sump pit with sump pumps (SP1 to SP4)Item1Total Amount of DivisionDivision 15 - Mechanical15.59Pressure brake MHItem115.60Acoustically insulated Soil Waste pipeItem15.61Sand trapItem115.62MiscellaneousDM approvals & coordination for same to obtain final permission to connectItem15.63Close-out documentationItemDRAINAGE SERVICES15.5450MM WPM52350MM VPM84350MM KWPM2080mm WPM32080mm KWPM65100mm WPM137100mm SPM130100mm VPM200100mm RWPM41150mm WPM455150mm SPM318150mm KWPM63150mm RWPM105200mm WPM114200mm SPM117150mm VPM52FCO150mmONo.180mmOM110Manhole Size 1200mm x 900mmUnit1Grease trap type C floor mounted 800mm x 2400mmGutter channel 250mm width with grating coverL10.755150mm O VP Vent cowl100mm O VP Vent cowlTotal Amount of DivisionDivision 15 - MechanicalAdditional Items15.64The Tenderer is to attach with this bill of quantities any additional items with quantities, enumerated or itemised and rates which are not previously included to complete the build-up of the lump-sum tender price for this section of the works. Should the Tenderer fail to insert any items here, it will be deemed that his lump sum price for the tender includes all items either shown on the drawings and described in the specification to represent the entire cost of the works and no subsequent claim for any additional item will be entertained.Division 15 - MechanicalDRAINAGE SERVICESTotal of Drainage ServicesPage 1Page 2Page 3Page 4Page 5Page 6Total Amount of DivisionDivision 15- MechanicalFIRE FIGHTING SERVICES15.65Unless otherwise stated the work shall pertain to the secondary design, obtaining approvals from Civil Defence, supply, installation, testing, commissioning, warranty and maintenance of the following works: All components to be UL listed or FM approved.15.66Sprinkler pipe as per NFPA 13 with threaded (up to 50mm) and victaulic end fittings (65mm & longer)ItemL/S15.67Automatic zone control valves, flow switches, drain valves, supervisory valves, etc. for system to comply with Civil Defence requirements.Item715.68Fire Hose reel cabinets with 30m hose 25 o, wet riser landing valve 65o & protable extinguishers.Item2015.69Sprinkler for entire area as per Civil Defence requirementsItem15.70Protable extinguishers in plant rooms and other areas as shown. CO2 & dry powder type as on Drawing. Generator rooms, cylinder rooms, etc.Item15.712 way breeching inlet cabinetsItem115.72Combined sprinkler & fire fighting pump set -- UL listedItem1 set15.72.1a) Electric motor driven pump vertical turbine type15.72.2b) Diesel Engine driven pump vertical turbine type15.72.3c) Jockey pump15.73With all associated valves, fuel oil tank etc and pump control panel.15.74FM200 system with associated controls, cylinders etc. as specified and as shown on drawing complete with room integrity testItem115.75CO2 system with controls as specified and as shown on drawing for fuel tank roomItem115.76Fuel tank for fuel storage with fill line, discharge line, pumps with valves and controls for filling of roof installed genset day tank.Item1Additional Items15.77The Tenderer is to attach with this bill of quantities any additional items with quantities, enumerated or itemised and rates which are not previously included to complete the build-up of the lump-sum tender price for this section of the works. Should the Tenderer fail to insert any items here, it will be deemed that his lump sum price for the tender includes all items either shown on the drawings and described in the specification or deemed necessary by the Tenderer to develop the drawings and specification to represent the entire cost of the works and no subsequent claim for any additional item will be entertained.Item1Total Amount of DivisionDivision 15 - MechanicalFire Fighting15.69Recessed Pendant Sprinklers HeadUnit275Upright Sprinkler HeadUnit245Side Wall SprinklerUnit8315.704.5 Kg. CO2 Fire ExtinguisherUnit204.5 Kg. Dry Powder Fire ExtinguisherUnit1315.714 Way Breeching Inlet CabinetUnit1Total Amount of DivisionDivision 15 - MechanicalFIRE FIGHTING SERVICESTotal ofPage 1Page 2Page 3Page 4Page 5Page 6Total Amount of DivisionDivision 15 - MechanicalLPG System15.78Supply, install, test & commission of LPG system comprising of:15.79LPG tank with all connections, valves and pipingNos.115.8Vaporizer as per specificationsNos.215.81Piping & fittings as per drawingItem15.82Gas leakage detection system interfaced to FA system as specifiedItem115.83As Built drawings, O & M manuals, schematics, shop drawings and other such fabrication & close-out documentation required by Client/EngineerItemTotal Amount of DivisionDivision 15 - MechanicalL.P.G. SystemTotal of LPG SystemsPage 1Page 2Page 3Page 4Page 5Page 6Total Amount of DivisionELECTRICAL SERVICES16.1Unless otherwise stated, the work shall pertain to the secondary design, supply, installation, testing commissioning, warranty & maintenance of the following works. Where quantities have not been included, the contractor shall indicate the quantities as per the Tender document.16.1.1Coordination with DEWA for the supply of power to LV panel installed under this contract. Cable already existing from MDB to SMDB in Electrical room as shown on the drawing.Item16.2Switch Gear SystemComplete with installation & termination of all outgoing cable to DBs.16.2.1MDB-1No.116.2.2MDB-2No.116.2.3MDB-3No.116.2.4SMDB-B3No.116.2.5SMDB-GFNo.116.2.6SMDB-MFNo.116.2.7SMDB-1FNo.116.2.8SMDB-2FNo.116.2.9SMDB-3FNo.116.2.10SMDB-4FNo.116.2.11SMDB-5FNo.116.2.12SMDB-6FNo.116.2.13SMDB-7FNo.116.2.14SMDB-RFNo.116.2.15SMDB-MDFNo.116.2.16SMDB-CBSNo.116.2.17SMDB-BKNo.116.2.18SMDB-MKNo.116.2.20ESMDB-GENNo.116.2.21DBs as per load schedule & drawings.Item16.3Capacitor Banks16.3.1Capacitor Bank-1No.116.3.2Capacitor Bank-2No.116.3.3Capacitor Bank-3No.116.4Motor Control CentreMCC complete with installation and termination of all outgoing cables to equipment control devices etc.16.4.1MCC-RF16.4.2EMCC - RF16.4.3.MCC-Chiller16.4.4MCC-Pump16.4.5MCC B116.4.6Uninterruptible power supply unit with batteryTotal Amount of PageDivision 16 - Electrical16.5Load Distribution Switches16.5.1300 A TP W/P IsolatorNo.616.5.2160 A TP W/P IsolatorNo.316.5.3125 A TP W/P IsolatorNo.416.5.4100 A TP W/P IsolatorNo.116.5.563 A TP W/P IsolatorNo.1016.5.640 A TP W/P IsolatorNo.216.5.732 A TP W/P IsolatorNo.4016.5.825 A TP W/P IsolatorNo.1016.5.920 A TP W/P IsolatorNo.316.5.1020 A SP W/P IsolatorNo.416.5.11Control panels including starters, control devices, etc.Item100 IP IsolatorNo.116.6Final sub-circuit and auxilliary installationsCable and conduit in concelaed installations to the following:16.6.1-aSocket Outlet 13A single switched socketNo.9416.6.1-bWIPNo.2516.6.3Double pole switchNo.16.6.4Connection point/outletNo.16.6.513A single switched socket explosion proofNo.16.6.613A double switched socketNo.7016.6.7Spur outlet (W/P)No.16.6.8Lock off stop push buttonNo.16.6.915A socket outletNo.4616.6.1020A DP (W/P) outlet with switch for water heater and with neon indicatorNo.4916.6.1120A DP outlet with spur outlet and with neon indicated and marker for hand dryer.No.816.6.12Connection point/outletNo.16.6.13Voice/data RJ45 outletsNo.16.6.14Light switches complete with all accessories. IP56 for all plant roomsNo.16.6.15Isolator (W/P) outlet with complete wiring and installation for equipment as per drawingNo.3516.6.17Floor box with no. 13A double socket + 2 RJ 45 socket and blank plate compete installation and wiring.No.16.6.18Industrial TP and SP socket for equipment as per drawingNo.3516.6.19Lighting pointNo.16.6.20Switch pointNo.16.6.21Cable trays as requiredItem16.6.22Trunking as requiredItem16.6.23PVC ducts as requiredItem16.6.24Light switches complete with all accessories, brush stainless steel for occupied areasItem16.7CCTV & Access ControlCCTV and Access control system complete with internal & external cameras to be connected to, monitors located in secuirty guard room for video monitoring of all perimeters & required internal areas. System to be compatible with existing monitors and equipment located in existing security guard room.Item16.80Structured Cabling SystemCat 6 Cable, patch panels & all and conduits in concealed and exposed installations:16.8.1Telephone outlet RJ45No.2216.8.2Data outlets RJ45No.2016.8.3Main incoming connections form the existing Etisalat JRC manholesItemTotal Amount of PageDivision 16 - Electrical16.9Fire alarm control panel complete with necessary accessories, brackets and fittings as per drawing and specifications.No.13116.9.1Smoke detectorNo.16016.9.2Smoke detector + buzzerNo.2816.9.3Heat detectorNo.1316.9.4Optical detectorNo.3916.9.5Sounder/sounder W/P16.9.6Manual call pointNo.116.9.7Fire alarm repeater panel16.9.8Allow for interface fire alarm system with fire fighting16.9.9Allow for interface fire alarm system with smoke panel16.9.10Allow for interface fire alarm system with liftNo.16.9.11Allow for interface FA system with automatic doorsNo.16.9.12Allow for interface FA system with fireman's switch.No.16.10Central Battery system & accessoriesNo.116.11Emergency light fittings with central battery backup (1x8w)No.16316.12Exit sign light fittings with central battery backupNo.14016.12.1Normal lighting fixtures with convertible kit to feed from central battery system on emergency condition.No.26216.12.2Analog abbressable break glassNo.3616.12.3Ceiling speaker (surface/recessed/wall mounted type)No.29716.132x9 W surface mounted circular light fittings on staircases with central battery backup16.14All fittings IP21 except in toilets to be IP65, external to be weather proofed and for riser storage & preparation and within paint booth areas to be sealed type explosion proof fittings.16.14.14 x 18W fluorescent light with louverNo.3316.14.24 x 18W fluorescent tube fitting HF control gear weather proofNo.16.14.32 x 36W fluorescent tube fitting with diffused as B typeNo.22216.14.41 x 36W fluorescent tube fitting as BB typeNo.316.14.5Down lighters (1 x 18W)No.1216.14.5.1Down lighters (2 x 9W)No.4516.14.5.22 x 9 surface mounted M.T.D. circular fluorescent light with PL lamp.No.5616.14.6Mirror lights type KNo.916.14.72 x 36W fluorescent explosion proof typeNo.3916.14.81 x 50W wall mounted light fittings IP65No.16.14.9External lights, as per drawingsNo.16.14.10Main Distribution frame (By others). Etisalat charges directly by client.No.116.14.11Patch panelsNo.16.14.12Telephone manholes with coversNo.116.14.13Twin voice/data RJ45 outletsNo.16.14.14Diesel engine generator of rating with accessories and controls and load test.No.1Total Amount of PageDivision 16 - Electrical16.15Sundries16.15.1Earthing and Bonding system of all metal structure, all panels, mechanical plant, etc.Item16.15.2Lighting protection systemItem16.15.3Other work associated with external cablingItem16.15.4Allow for associated ducting for electrical and LV services.ItemAdditional Items16.16The tenderer is to attach with this bill of quantities any additional items with quantities, enumerated or itemized and rates which are not previously included to complete the build-up of the lump-sum tender price for this section of the works. Should the Tenderer fail to insert any items here, it will be deemed that this lump sum price for the tender includes all items either shown on the drawings and described in the specification or deemed necessary by the Tenderer to develop the drawings and specification to represent the entire cost of the works and no subsequent claim for any additional item will be entertained.ItemTotal Amount of PageDivision 16 - ElectricalTotal of Electrical ServicesPage 1Page 2Page 3Page 4Page 5Page 6Total Amount of DivisionOther works associated with MEP ServicesPreparation of working drawings and carrying out the secondary design associated with the preparation of the working drawings and material/equipment submittalsItemTesting & CommissioningItemProvision of O & M manuals, As-Built drawingsItemInsurance as per contract conditionsItemWarranty of worksItemCoordination with local authorities and paymentsItem14 months operation; attendace and maintenance of all MEP installationsTotal Amount of DivisionTotal Amount of Division 15 - MechanicalTotal Amount of Division 16 - ElectricalMobilizationTotal Lump Sum Price in AED

&L&"Arial,Bold"&12NAGA&"Arial,Regular"&10&8Architects Designers Planners&10&8Dubai Atlanta Alexandria Amsterdam&R&8Issue for Tender Rev (0)&L&8DXB 06-13 Lotus HotelBOQ&R&8Section 01200 - BOQPage 37 of 37