Column Design 1Lecture 24

Architectural Structures IENDS 231

S2008abn

ARCHITECTURAL STRUCTURES I:STATICS AND STRENGTH OF MATERIALS ENDS 231

DR. ANNE NICHOLS

SPRING 2008

lecturetwenty four

column design

Column Design 2Lecture 24

Architectural Structures IENDS 231

S2008abn

Design Methods• know

– loads or lengths• select

– section or load– adequate for

strength and no buckling

Column Design 3Lecture 24

Architectural Structures IENDS 231

S2008abn

Allowable Stress Design (ASD)• AICS 9th ed

• slenderness ratio

– for kl/r ≥ Cc

( )22

23

12..

rKlE

SFfF critical

==

rKl

= 126.1 with Fy = 36 ksi= 107.0 with Fy = 50 ksi

Column Design 4Lecture 24

Architectural Structures IENDS 231

S2008abn

Cc and Euler’s Formula• Kl/r < Cc

– short and stubby– parabolic transition

• Kl/r > Cc– Euler’s relationship– < 200 preferred

yc F

EC22π

=

Column Design 5Lecture 24

Architectural Structures IENDS 231

S2008abn

Cc and Euler’s Formula

Column Design 6Lecture 24

Architectural Structures IENDS 231

S2008abn

Short / Intermediate • Le/r < Cc

– where

( )..2

1 2

2

SFF

Cr

KlF y

ca

⎥⎥⎥

⎢⎢⎢

⎡−=

( ) ( )3

3

88

3

35..

cc Cr

Kl

Cr

KlSF −+=

Column Design 7Lecture 24

Architectural Structures IENDS 231

S2008abn

Procedure for Analysis1. calculate KL/r

• biggest of KL/r with respect to x axes and y axis

2. find Fa from Table 10.1 or 10.2• pp. 361 - 364

3. compute Pallowable = Fa⋅A• or find factual = P/A

4. is P ≤ Pallowable? (or is factual ≤ Fa?)• yes: ok• no: overstressed and no good

Column Design 8Lecture 24

Architectural Structures IENDS 231

S2008abn

Procedure for Design1. guess a size (pick a section)2. calculate KL/r

• biggest of KL/r with respect to x axes and y axis

3. find Fa from Table 10.1 or 10.2• pp. 361 - 364

4. compute Pallowable = Fa⋅A• or find factual = P/A

Column Design 9Lecture 24

Architectural Structures IENDS 231

S2008abn

Procedure for Design (cont’d)5. is P ≤ Pallowable? (or is factual ≤ Fa?)

• yes: ok• no: pick a bigger section and go back to step

2.

6. check design efficiency

• percentage of stress =

• if between 90-100%: good• if < 90%: pick a smaller section and go back

to step 2.

%PP

allowable

actual 100⋅

Column Design 10Lecture 24

Architectural Structures IENDS 231

S2008abn

Column Charts

Column Design 11Lecture 24

Architectural Structures IENDS 231

S2008abn

Column Charts

Column Design 12Lecture 24

Architectural Structures IENDS 231

S2008abn

Wood Columns• slenderness ratio = L/dmin = L/d1

– d1 = smaller dimension– le/d ≤ 50 (max)

– where is the allowable compressive strength parallel to the grain

cc FAPf ′≤=

cF ′

Column Design 13Lecture 24

Architectural Structures IENDS 231

S2008abn

Allowable Wood Stress

• where:Fc = compressive strength

parallel to grainCD = load duration factorCM = wet service factor

(1.0 dry)Ct = temperature factorCF = size factorCp = column stability factor

( )( )( )( )( )pFtMDcc CCCCCFF =′

(Table 10.3)

Column Design 14Lecture 24

Architectural Structures IENDS 231

S2008abn

Strength Factors• wood properties and load duration, CD

– short duration• higher loads

– normal duration • > 10 years

• stability, Cp– combination curve - tables

( ) pDcpcc CCFCFF ==′ *

Column Design 15Lecture 24

Architectural Structures IENDS 231

S2008abn

Cp Charts – Appendix A, Table 14

Column Design 16Lecture 24

Architectural Structures IENDS 231

S2008abn

Column Charts – Appendix A, 12 & 13

Column Design 17Lecture 24

Architectural Structures IENDS 231

S2008abn

Procedure for Analysis1. calculate Le/dmin

2. obtain F´c– compute

• KcE =0.3 sawn • KcE = 0.418 glu-lam

3. compute Fc* ≈ FcCD

4. calculate FcE/Fc* and get Cp (table 14)

5. calculate

( )2dLcE

cEe

EKF =

pcc CFF *=′

Column Design 18Lecture 24

Architectural Structures IENDS 231

S2008abn

Procedure for Analysis (cont’d)6. compute Pallowable = F′c⋅A

• or find factual = P/A

7. is P ≤ Pallowable? (or factual ≤ F′c?)• yes: OK• no: overstressed & no good

Column Design 19Lecture 24

Architectural Structures IENDS 231

S2008abn

Procedure for Design1. guess a size (pick a section)2. calculate Le/dmin

3. obtain F´c– compute

• KcE =0.3 sawn • KcE = 0.418 glu-lam

4. compute Fc* ≈ FcCD

5. calculate FcE/Fc* and get Cp (table 14)

6. calculate

( )2dLcE

cEe

EKF =

pcc CFF *=′

Column Design 20Lecture 24

Architectural Structures IENDS 231

S2008abn

Procedure for Design (cont’d)6. compute Pallowable = F′c⋅A

• or find factual = P/A

7. is P ≤ Pallowable? (or factual ≤ F′c?)• yes: OK• no: pick a bigger section and go back to step 2.

Column Design 21Lecture 24

Architectural Structures IENDS 231

S2008abn

LRFD design• limit states for failure

1. yielding

2. buckling

λc – column slenderness parameterAg - gross area

ncu PP φ≤

gcrnc AFP == 85.0φ

5.1≤cλ

5.1>cλEF

rKl y

c πλ = r

Le

Column Design 22Lecture 24

Architectural Structures IENDS 231

S2008abn

• flanges continuously connected to the web or webs and width-thickness rations < limiting values– no local buckling of flange or web

– for

– for

Compact Sections

5.1≤cλ

5.1>cλ

( ) yλ

cr F.F c2

6580=

yc

cr Fλ.F ⎥

⎤⎢⎣

⎡= 2

8770

Column Design 23Lecture 24

Architectural Structures IENDS 231

S2008abn

Column Charts