12
Electronic Pressure Measurement R Ultra High Purity Transducer Models WU-10, WU-15 and WU-16 with and without side access Page 1 of 12 WIKA Datasheet WU-1X · 2/2013 WIKA Datasheet WU-1X Fig. left Transducer WU-10, Single End Fig. center Transducer WU-15, Flow Through Fig. right Transducer WU-16, Modular Surface Mount Applications Semiconductor and flat panel display industry Microelectronics engineering Gas distribution systems (Gas sticks, gas panels, bulk-gas supply) Ultra high purity water supply Special Features Thin-film sensor Excellent long-term stability Exchangeable electronics No span adjustment required Ingress protection IP 65 / IP 54 with side access Standard Features Universal As a result of its broad pressure range spectrum from vacuum up to 400 bar (5000 psi), its compact design and its excellent performance, model WU-10 offers a perfect combination of an appealing design and proven measuring technology. Flow through transducers of the WU-15 series have been developed for ultra pure media applications where, apart from the requirement for easy cleaning of the transducer, the application also demands a proven, stable sensor technolo- gy.Through the optimised design of the sensor connection, external influences on the sensor signal have been eliminated, even in the case of varying fastening torques of the process connections. Reliable Thin-film sensors produced by WIKA have ensured high accuracy, long-term stability and repeatabillity in industrial pressure measurement instrumentation for decades. We use special thin-film sensors made of 2.4711 / UNSR 30003 in order to meet the particular requirements of the ultra pure media industry. Hermetically welding of the thin-film sensor guarantees a total separation of medium, as well as a long-term high impermea- bility which is required by the user. Versatile The modular design makes it possible to configure a high number of variants in order to comply with the manifold requi- rements of UHP applications. All wetted parts are electropolished using state-of-the art equipment prior to the final assembly. The integrated potentiometer enables adjustment of the zero point up to 5% of the full scale value. An adjustment of span is not required. Exchangeable electronics enable replacement of the amplifier without disconnecting the sensors from the process. The high ingress protection (NEMA-4) allows operation even under the most difficult conditions. UHP Attachable indicator with LED; Model WUR-1; see Data Sheet WUR-1

Transcript of Ultra High Purity Transducer Model WU-1X - WIKA · Ultra High Purity Transducer Models WU-10, WU-15...

Page 1: Ultra High Purity Transducer Model WU-1X - WIKA · Ultra High Purity Transducer Models WU-10, WU-15 and WU-16 with and without side access WIKA Datasheet WU-1X · 2/2013 Page 1 of

ElectronicPressure Measurement

R

Ultra High Purity TransducerModels WU-10, WU-15 and WU-16with and without side access

Page 1 of 12WIKA Datasheet WU-1X · 2/2013

WIKA Datasheet WU-1X

Fig. left Transducer WU-10, Single End Fig. center Transducer WU-15, Flow Through

Fig. right Transducer WU-16, Modular Surface Mount

Applications

Semiconductorandflatpaneldisplayindustry Microelectronicsengineering Gasdistributionsystems (Gassticks,gaspanels,bulk-gassupply)

Ultrahighpuritywatersupply

Special Features

Thin-filmsensor Excellentlong-termstability Exchangeableelectronics

Nospanadjustmentrequired IngressprotectionIP65/IP54withsideaccess

Standard Features

UniversalAsaresultofitsbroadpressurerangespectrumfromvacuumupto400bar(5000psi),itscompactdesignanditsexcellentperformance,modelWU-10offersaperfectcombinationofanappealingdesignandprovenmeasuringtechnology.

FlowthroughtransducersoftheWU-15serieshavebeendevelopedforultrapuremediaapplicationswhere,apartfromtherequirementforeasycleaningofthetransducer,theapplicationalsodemandsaproven,stablesensortechnolo-gy.Throughtheoptimiseddesignofthesensorconnection,externalinfluencesonthesensorsignalhavebeeneliminated,eveninthecaseofvaryingfasteningtorquesoftheprocessconnections.

ReliableThin-filmsensorsproducedbyWIKAhaveensuredhighaccuracy,long-termstabilityandrepeatabillityinindustrialpressuremeasurementinstrumentationfordecades.Weusespecialthin-filmsensorsmadeof2.4711/UNSR30003inordertomeettheparticularrequirementsoftheultrapuremediaindustry.

Hermeticallyweldingofthethin-filmsensorguaranteesatotalseparationofmedium,aswellasalong-termhighimpermea-bilitywhichisrequiredbytheuser.

VersatileThemodulardesignmakesitpossibletoconfigureahighnumberofvariantsinordertocomplywiththemanifoldrequi-rementsofUHPapplications.Allwettedpartsareelectropolishedusingstate-of-theartequipmentpriortothefinalassembly.

Theintegratedpotentiometerenablesadjustmentofthezeropointupto5%ofthefullscalevalue.Anadjustmentofspanisnotrequired.

Exchangeableelectronicsenablereplacementoftheamplifierwithoutdisconnectingthesensorsfromtheprocess.Thehighingressprotection(NEMA-4)allowsoperationevenunderthemostdifficultconditions.

UHPAttachableindicatorwithLED;ModelWUR-1;seeDataSheetWUR-1

Page 2: Ultra High Purity Transducer Model WU-1X - WIKA · Ultra High Purity Transducer Models WU-10, WU-15 and WU-16 with and without side access WIKA Datasheet WU-1X · 2/2013 Page 1 of

Page 2 of 12 WIKA Datasheet WU-1X · 2/2013

Specifications Models WU-10, WU-15, WU-16WU-10 / WU-15

WU-16Pressure ranges bar 4 7 10 16 25 40 60 100 160 250 400

psi 60 100 160 250 300 500 1000 1500 2000 3000 5000Overpressuresafety bar 8 14 20 32 50 80 120 200 320 500 690Burstpressure bar 40 70 100 160 250 510 550 720 720 720 720

Otherpressurerangesandpressureunits(e.g.MPa,kg/cm2)onrequest1bar=14.50psi

Measuringprinciple MetalthinfilmsensorMaterials■Wettedparts 2.4711/UNSR30003(sensor);316LVIM/VAR(Processconnection)■ Case StainlesssteelSurfacefinish Electropolished,typicalRa≤0.18µm(RA7);max.Ra≤ 0.25µm(RA10)Deadvolume mm3 WU-10<1500,WU-15<1000,WU-16<1000PermissibleMedium Liquid/Gas/VaporPowersupplyUB UBinVDC 10 < UB ≤ 30(14...30withoutputsignal0.1...10.1Vand0...10V)Capacitiveload µF Max.0.1(Voltageoutput)Max.currentconsumption mA <1Voltageoutputsignal;Source

mA <30CurrentoutputsignalAdjustabilityzero %ofspan ±5viapotentiometerResponsetime(10...90%) ms ≤ 100 Dielectricstrength VDC 500Accuracy %ofspan ≤0.5 2)forpressureranges>4bar

%ofspan ≤1.0 2)forpressureranges≤4bar2) Includingnon-linearity,hysteresis,zeropointandfullscaleerror (correspondstoerrorofmeasurementperIEC61298-2). Adjustedinverticalmountingpositionwithlowerpressureconnection.

Non-linearity %ofspan ≤0.15 forpressureranges>4bar (BFSL)accordingtoIEC61298-2%ofspan ≤0.3 forpressureranges≤4bar (BFSL)accordingtoIEC61298-2

Hysteresis %ofspan ≤0.201-yearstability %ofspan ≤0.2 (atreferenceconditions)Permissibletemperatureof■ Medium -20...+100°C -4...+212°F■ Ambience -20...+85°C -4...+185°F■ Storage -40...+100°C -40...+212°FCompensatedtemp.range -20...+80°C -4...+176°FTemperaturecoefficientswithincompensatedtemperaturerange: ■meanTCofzero/10K %ofspan ≤0.1■ mean TC of range / 10 K %ofspan ≤0.15RoHS-conformitystatement Yes(notwithbayonetconnector)CE-conformityPressureequipmentdirective 97/23/EG■EMCdirective 89/336/EECemission(classB)andimmunityaccordingtoEN61326Shock resistance g 500accordingtoIEC60068-2-27 (mechanicalshock)Vibrationresistance g 10accordingtoIEC60068-2-6 (vibrationunderresonance)Wiringprotection■Short-circuitproofness Sig+towardsUB-■Reversepolarityprotection UB+towardsUB-Mass kg Approx.0.1

Page 3: Ultra High Purity Transducer Model WU-1X - WIKA · Ultra High Purity Transducer Models WU-10, WU-15 and WU-16 with and without side access WIKA Datasheet WU-1X · 2/2013 Page 1 of

Page 3 of 12WIKA Datasheet WU-1X · 2/2013

Output signal and allowed load

Output current (2-wire)4...20mA:RA < (UB–10V)/0.02AOutput voltage (3-wire)0.1...5.1V: RA>5kOhm0.1...10.1V: RA>10kOhm0...5V: RA>5kOhm0...10V:RA>10kOhmwithRA in Ohm and UBinVDC

4...20mA,2-wire

permittedrange

Dimensions in inch [mm] WU-10

Process connection variants

with side access (IP 54 / Nema 3S)

¼"SwivelFemaleFaceSeal,Ordercode:72

CircularconnectorOrdercode:M4

¼"T-Connector,WeldStub(1")Ordercode:WR

¼"SwivelMaleFaceSeal,Ordercode:71

¼"T-Connector,WeldStubOrdercode:WT

Page 4: Ultra High Purity Transducer Model WU-1X - WIKA · Ultra High Purity Transducer Models WU-10, WU-15 and WU-16 with and without side access WIKA Datasheet WU-1X · 2/2013 Page 1 of

Page4of12 WIKA Datasheet WU-1X · 2/2013

Dimensions in inch [mm] WU-15

Process connection variants

CircularconnectorOrdercode:M4

¼"SwivelFemaleFaceSeal,Ordercode:72¼"SwivelFemaleFaceSeal,Ordercode:72

¼"SwivelFemaleFaceSealOrdercode:72,¼"SwivelMaleFaceSealOrdercode:71

¼"FixedMaleFaceSealOrdercode:WG¼"SwivelFemaleFaceSealOrdercode:72,

¼"FixedMaleFaceSeal,Ordercode:WG¼"SwivelMaleFaceSeal,Ordercode:71

¼"SwivelMaleFaceSeal,Ordercode:71¼"SwivelMaleFaceSeal,Ordercode:71

¼"WeldStub,Ordercode:VN¼"WeldStub,Ordercode:VN

¼"FixedMaleFaceSeal,Ordercode:WG¼"WeldStub,Ordercode:VN

with side access (IP 54 / Nema 3S)

Page 5: Ultra High Purity Transducer Model WU-1X - WIKA · Ultra High Purity Transducer Models WU-10, WU-15 and WU-16 with and without side access WIKA Datasheet WU-1X · 2/2013 Page 1 of

Page5of12WIKA Datasheet WU-1X · 2/2013

Dimensions in inch [mm] WU-16

Process connection variants

MSM C 1½" SQ,Ordercode:WC

MSMW1⅛"Ordercode:WF

BayonetconnectorOrdercode:O4

MSM W 1½"Ordercode:WD

MSMC1⅛"SQOrdercode:WE

¼"FixedMaleFaceSeal,Ordercode:WG¼"FixedMaleFaceSeal,Ordercode:WG

Process connection variants WU-15

with side access (IP 54 / Nema 3S)

¼"FixedMaleFaceSealHighFlowThrough,OrderCode:WM¼"FixedMaleFaceSealHighFlowThrough,OrderCode:WMonlyavailablewithpressurerangesupto25bar/300psi

Page 6: Ultra High Purity Transducer Model WU-1X - WIKA · Ultra High Purity Transducer Models WU-10, WU-15 and WU-16 with and without side access WIKA Datasheet WU-1X · 2/2013 Page 1 of

Page6of12 WIKA Datasheet WU-1X · 2/2013

Specificationsanddimensionsgiveninthisleafletrepresentthestateofengineeringatthetimeofprinting.Modificationsmaytakeplaceandmaterialsspecifiedmaybereplacedbyotherswithoutpriornotice.

FlyingleadsIP65(NEMA4)*)Ordercode:DI

Bayonetconnector4-pin,IP65(NEMA4)*)Ordercode:O4

SUB-D connector15-pin,IP54(NEMA3S)Ordercode:TX

CircularconnectorM 12x14-pin,IP65(NEMA4)*)Ordercode:M4

*)withsideaccessIP54(NEMA3S)

3-wire2-wireDimensions in inch [mm]

red red

black

brown

black

Dimensions and wiring details WU-1X IngressProtectionIPperIEC60529

Page 7: Ultra High Purity Transducer Model WU-1X - WIKA · Ultra High Purity Transducer Models WU-10, WU-15 and WU-16 with and without side access WIKA Datasheet WU-1X · 2/2013 Page 1 of

Page7of12WIKA Datasheet WU-1X · 2/2013

WU-10 Smart Codes for Custom Order Configurations Field No. Code Feature

Signal Output A 4...20mA,2-wire F 0...10V,3-wire 1 G 0...5V,3-wire Unit B bar P psi 3 psiabsolute 2 ? other (MPa, kPa, kg/cm2, etc.) Pressure Range CH -1...+3bar1) -30inHg...100psi CT -1...+6bar CL -1...+9bar CP -1...+15bar CQ -1...+25bar CX -1...+40bar -30inHg...500psi CY -1...+60bar C1 -1...+100bar C2 -1...+160bar C3 -1...+250bar BG 0...4bar1) 0...160psi EF 0...7bar BI 0...10bar 0...300psI BK 0...16bar BL 0...25bar BM 0...40bar BN 0...60bar 0...1000psi BO 0...100bar 0...1500psi BP 0...160bar 0...2000psi BQ 0...250bar 0...3000psi BS 0...400bar 0...5000psi CE -30inHg...45psi1) CF -30inHg...60psi1) CK -30inHg...160psi CI -30inHg...250psi CM -30inHg...300psi BE 0...60psi1) BF 0...100psi DG 0...250psi DI 0...500psi 3 ?? other

1)Accuracy1.0%ofspan

Page 8: Ultra High Purity Transducer Model WU-1X - WIKA · Ultra High Purity Transducer Models WU-10, WU-15 and WU-16 with and without side access WIKA Datasheet WU-1X · 2/2013 Page 1 of

Page 8 of 12 WIKA Datasheet WU-1X · 2/2013

WU-10 Smart Codes for Custom Order Configurations (continued)

Field No. Code Feature

1)Accuracy1.0%ofspan

12345678910*WU-10 - - - - B G - Z

*Additionalorderdetails

OrderCode:

Process Connection WR ¼"T-connector(1"version) 71 OriginalVCR-malenutSS4-VCR-4 (FSM) 72 OriginalVCR-unionnutSS4-VCR-1 (FSF) 4 ?? other Dampening Z Without 5 A >100ms always with side access Electrical connection M4 4-pinlockingplugM12x1 DI flyinglead,IP65 O4 4-pinbayonetconnector (Bendix) 6 ?? other Cable Length Z Without always choose if plug version E 3 m 7 ? other Special Design Features Z Without 8 1 Zeropotentiometerwithsideaccessalways choose with dampening Additional Order Info9 1 qualitycertificate 10 T additionaltext

Page 9: Ultra High Purity Transducer Model WU-1X - WIKA · Ultra High Purity Transducer Models WU-10, WU-15 and WU-16 with and without side access WIKA Datasheet WU-1X · 2/2013 Page 1 of

Page9of12WIKA Datasheet WU-1X · 2/2013

WU-15 Smart Codes for Custom Order Configurations Field No. Code Feature

Signal OutputA 4 ... 20 mA, 2-wireF 0 ... 10 V, 3-wire

1 G 0 ... 5 V, 3-wireUnit

B barP psi? other (MPa, kPa, kg/cm2, etc.)

2 3 psi absolute Pressure RangeCH -1 ... +3 bar1) -30 inHg ... 100 psiCT -1 ... +6 barCL -1 ... +9 barCP -1 ... +15 barCQ -1 ... +25 barCX -1 ... +40 bar -30 inHg ... 500 psiCY -1 ... +60 barC1 -1 ... +100 barC2 -1 ... +160 barC3 -1 ... +250 barBG 0 ... 4 bar 1) 0 ... 160 psi EF 0 ... 7 barBI 0 ... 10 bar 0 ... 300 psiBK 0 ... 16 barBL 0 ... 25 barBM 0 ... 40 barBN 0 ... 60 bar 0 ... 1000 psiBO 0 ... 100 bar 0 ... 1500 psiBP 0 ... 160 bar 0 ... 2000 psiBQ 0 ... 250 bar 0 ... 3000 psiBS 0 ... 400 bar 0 ... 5000 psiCE -30 inHg ... 45 psi 1)

CF -30 inHg ... 60 psi 1)

CK -30 inHg ... 160 psiCI -30 inHg ... 250 psiCM -30 inHg ... 300 psiBE 0 ... 60 psi1)

BF 0 ... 100 psiDG 0 ... 250 psiDI 0 ... 500 psi

3 ?? other

Page 10: Ultra High Purity Transducer Model WU-1X - WIKA · Ultra High Purity Transducer Models WU-10, WU-15 and WU-16 with and without side access WIKA Datasheet WU-1X · 2/2013 Page 1 of

Page 10 of 12 WIKA Datasheet WU-1X · 2/2013

WU-15 Smart Codes for Custom Order Configurations (continued) Field No. Code Feature

1)Accuracy1.0%ofspan

1234567891011*WU-15 - - - - B G - Z

*Additionalorderdetails

OrderCode:

Process Connection VN ¼"weldstub WG ¼"fixedmalefaceseal WM ¼"fixedmalefaceseal,highflow (pressures up to 25 bar/300psi) 71 OriginalVCR-malenutSS4-VCR-4 (FSM) 72 OriginalVCR-unionnutSS4-VCR-1 (FSF) 4 ?? other Outlet Process Connection VN ¼"weldstub WG ¼"fixedmalefaceseal WM ¼"fixedmalefaceseal,highflowthrough(pressures up to 25 bar/300psi) 71 OriginalVCR-malenutSS4-VCR-4 (FSM) 72 OriginalVCR-unionnutSS4-VCR-1 (FSF) 5 ?? other Dampening Z Without 6 A >100ms always with side access Electrical Connection M4 4-pinlockingplugM12x1 DI flyinglead,IP65 O4 4-pinbayonetconnector (Bendix) 7 ?? other Cable Length Z Without always choose if plug version

E 3 m 8 ? other Special Design Features Z Without 9 1 Zeropotentiometerwithsideaccess Additional order info YES NO 10 1 Z qualitycertificates 11 T Z additionaltext

Page 11: Ultra High Purity Transducer Model WU-1X - WIKA · Ultra High Purity Transducer Models WU-10, WU-15 and WU-16 with and without side access WIKA Datasheet WU-1X · 2/2013 Page 1 of

Page 11 of 12WIKA Datasheet WU-1X · 2/2013

WU-16 Smart Codes for Custom Order Configurations Field No. Code Feature

Signal Output A 4...20mA,2-wire F 0...10V,3-wire 1 G 0...5V,3-wire Unit B bar P psi ? other (MPa, kPa, kg/cm2, etc.) 2 3 psiabsolute Pressure Range CH -1...+3bar1) -30inHg...100psi CT -1...+6bar CL -1...+9bar CP -1...+15bar CQ -1...+25bar CX -1...+40bar -30inHg...500psi BG 0...4bar1) 0...160psi EF 0...7bar BI 0...10bar 0...300psi BK 0...16bar BL 0...25bar BM 0...40bar CE -30inHg...45psi1) CF -30inHg...60psi1) CK -30inHg...160psi CI -30inHg...250psi CM -30inHg...300psi BE 0...60psi1) BF 0...100psi DG 0...250psi DI 0...500psi 3 ?? other Process Connection WE MSMC1⅛"SQ WF MSMW1⅛" 4 ?? other Dampening Z Without 5 A >100ms always with side access

1)Accuracy1.0%ofspan

Page 12: Ultra High Purity Transducer Model WU-1X - WIKA · Ultra High Purity Transducer Models WU-10, WU-15 and WU-16 with and without side access WIKA Datasheet WU-1X · 2/2013 Page 1 of

WIKA Instrument, LP1000 Wiegand Boulevard Lawrenceville, GA 30043-5868Tel: 888-WIKA-USA•770-513-8200Fax: 678-739-2569E-Mail: [email protected]/uhp

R

WIKA Datasheet WU-1X · 2/2013Page 12 of 12

Specificationsanddimensionsgiveninthisleafletrepresentthestateofengineeringatthetimeofprinting.Modificationsmaytakeplaceandmaterialsspecifiedmaybereplacedbyotherswithoutpriornotice.

WU-16 Smart Codes for Custom Order Configurations (continued) Field No. Code Feature

1)Accuracy1.0%ofspan

1234 56789 10*WU-16 - - - - B G - Z

*Additionalorderdetails

OrderCode:

Electrical connection M4 4-pinlockingplugM12x1 DI flyinglead,IP65 O4 4-pinbayonetconnector (Bendix) TX 15-pinhighdensitySub-Dplug6 ?? other Cable length Z without (always choose if plug version) E 3 m 7 ? other Special design features Z without 8 1 Zeropotentiometerwithsideaccess Additional order info YES NO 9 1 Z qualitycertificates 10 T Z additionaltext