ElectronicPressure Measurement
R
Ultra High Purity TransducerModels WU-10, WU-15 and WU-16with and without side access
Page 1 of 12WIKA Datasheet WU-1X · 2/2013
WIKA Datasheet WU-1X
Fig. left Transducer WU-10, Single End Fig. center Transducer WU-15, Flow Through
Fig. right Transducer WU-16, Modular Surface Mount
Applications
Semiconductorandflatpaneldisplayindustry Microelectronicsengineering Gasdistributionsystems (Gassticks,gaspanels,bulk-gassupply)
Ultrahighpuritywatersupply
Special Features
Thin-filmsensor Excellentlong-termstability Exchangeableelectronics
Nospanadjustmentrequired IngressprotectionIP65/IP54withsideaccess
Standard Features
UniversalAsaresultofitsbroadpressurerangespectrumfromvacuumupto400bar(5000psi),itscompactdesignanditsexcellentperformance,modelWU-10offersaperfectcombinationofanappealingdesignandprovenmeasuringtechnology.
FlowthroughtransducersoftheWU-15serieshavebeendevelopedforultrapuremediaapplicationswhere,apartfromtherequirementforeasycleaningofthetransducer,theapplicationalsodemandsaproven,stablesensortechnolo-gy.Throughtheoptimiseddesignofthesensorconnection,externalinfluencesonthesensorsignalhavebeeneliminated,eveninthecaseofvaryingfasteningtorquesoftheprocessconnections.
ReliableThin-filmsensorsproducedbyWIKAhaveensuredhighaccuracy,long-termstabilityandrepeatabillityinindustrialpressuremeasurementinstrumentationfordecades.Weusespecialthin-filmsensorsmadeof2.4711/UNSR30003inordertomeettheparticularrequirementsoftheultrapuremediaindustry.
Hermeticallyweldingofthethin-filmsensorguaranteesatotalseparationofmedium,aswellasalong-termhighimpermea-bilitywhichisrequiredbytheuser.
VersatileThemodulardesignmakesitpossibletoconfigureahighnumberofvariantsinordertocomplywiththemanifoldrequi-rementsofUHPapplications.Allwettedpartsareelectropolishedusingstate-of-theartequipmentpriortothefinalassembly.
Theintegratedpotentiometerenablesadjustmentofthezeropointupto5%ofthefullscalevalue.Anadjustmentofspanisnotrequired.
Exchangeableelectronicsenablereplacementoftheamplifierwithoutdisconnectingthesensorsfromtheprocess.Thehighingressprotection(NEMA-4)allowsoperationevenunderthemostdifficultconditions.
UHPAttachableindicatorwithLED;ModelWUR-1;seeDataSheetWUR-1
Page 2 of 12 WIKA Datasheet WU-1X · 2/2013
Specifications Models WU-10, WU-15, WU-16WU-10 / WU-15
WU-16Pressure ranges bar 4 7 10 16 25 40 60 100 160 250 400
psi 60 100 160 250 300 500 1000 1500 2000 3000 5000Overpressuresafety bar 8 14 20 32 50 80 120 200 320 500 690Burstpressure bar 40 70 100 160 250 510 550 720 720 720 720
Otherpressurerangesandpressureunits(e.g.MPa,kg/cm2)onrequest1bar=14.50psi
Measuringprinciple MetalthinfilmsensorMaterials■Wettedparts 2.4711/UNSR30003(sensor);316LVIM/VAR(Processconnection)■ Case StainlesssteelSurfacefinish Electropolished,typicalRa≤0.18µm(RA7);max.Ra≤ 0.25µm(RA10)Deadvolume mm3 WU-10<1500,WU-15<1000,WU-16<1000PermissibleMedium Liquid/Gas/VaporPowersupplyUB UBinVDC 10 < UB ≤ 30(14...30withoutputsignal0.1...10.1Vand0...10V)Capacitiveload µF Max.0.1(Voltageoutput)Max.currentconsumption mA <1Voltageoutputsignal;Source
mA <30CurrentoutputsignalAdjustabilityzero %ofspan ±5viapotentiometerResponsetime(10...90%) ms ≤ 100 Dielectricstrength VDC 500Accuracy %ofspan ≤0.5 2)forpressureranges>4bar
%ofspan ≤1.0 2)forpressureranges≤4bar2) Includingnon-linearity,hysteresis,zeropointandfullscaleerror (correspondstoerrorofmeasurementperIEC61298-2). Adjustedinverticalmountingpositionwithlowerpressureconnection.
Non-linearity %ofspan ≤0.15 forpressureranges>4bar (BFSL)accordingtoIEC61298-2%ofspan ≤0.3 forpressureranges≤4bar (BFSL)accordingtoIEC61298-2
Hysteresis %ofspan ≤0.201-yearstability %ofspan ≤0.2 (atreferenceconditions)Permissibletemperatureof■ Medium -20...+100°C -4...+212°F■ Ambience -20...+85°C -4...+185°F■ Storage -40...+100°C -40...+212°FCompensatedtemp.range -20...+80°C -4...+176°FTemperaturecoefficientswithincompensatedtemperaturerange: ■meanTCofzero/10K %ofspan ≤0.1■ mean TC of range / 10 K %ofspan ≤0.15RoHS-conformitystatement Yes(notwithbayonetconnector)CE-conformityPressureequipmentdirective 97/23/EG■EMCdirective 89/336/EECemission(classB)andimmunityaccordingtoEN61326Shock resistance g 500accordingtoIEC60068-2-27 (mechanicalshock)Vibrationresistance g 10accordingtoIEC60068-2-6 (vibrationunderresonance)Wiringprotection■Short-circuitproofness Sig+towardsUB-■Reversepolarityprotection UB+towardsUB-Mass kg Approx.0.1
Page 3 of 12WIKA Datasheet WU-1X · 2/2013
Output signal and allowed load
Output current (2-wire)4...20mA:RA < (UB–10V)/0.02AOutput voltage (3-wire)0.1...5.1V: RA>5kOhm0.1...10.1V: RA>10kOhm0...5V: RA>5kOhm0...10V:RA>10kOhmwithRA in Ohm and UBinVDC
4...20mA,2-wire
permittedrange
Dimensions in inch [mm] WU-10
Process connection variants
with side access (IP 54 / Nema 3S)
¼"SwivelFemaleFaceSeal,Ordercode:72
CircularconnectorOrdercode:M4
¼"T-Connector,WeldStub(1")Ordercode:WR
¼"SwivelMaleFaceSeal,Ordercode:71
¼"T-Connector,WeldStubOrdercode:WT
Page4of12 WIKA Datasheet WU-1X · 2/2013
Dimensions in inch [mm] WU-15
Process connection variants
CircularconnectorOrdercode:M4
¼"SwivelFemaleFaceSeal,Ordercode:72¼"SwivelFemaleFaceSeal,Ordercode:72
¼"SwivelFemaleFaceSealOrdercode:72,¼"SwivelMaleFaceSealOrdercode:71
¼"FixedMaleFaceSealOrdercode:WG¼"SwivelFemaleFaceSealOrdercode:72,
¼"FixedMaleFaceSeal,Ordercode:WG¼"SwivelMaleFaceSeal,Ordercode:71
¼"SwivelMaleFaceSeal,Ordercode:71¼"SwivelMaleFaceSeal,Ordercode:71
¼"WeldStub,Ordercode:VN¼"WeldStub,Ordercode:VN
¼"FixedMaleFaceSeal,Ordercode:WG¼"WeldStub,Ordercode:VN
with side access (IP 54 / Nema 3S)
Page5of12WIKA Datasheet WU-1X · 2/2013
Dimensions in inch [mm] WU-16
Process connection variants
MSM C 1½" SQ,Ordercode:WC
MSMW1⅛"Ordercode:WF
BayonetconnectorOrdercode:O4
MSM W 1½"Ordercode:WD
MSMC1⅛"SQOrdercode:WE
¼"FixedMaleFaceSeal,Ordercode:WG¼"FixedMaleFaceSeal,Ordercode:WG
Process connection variants WU-15
with side access (IP 54 / Nema 3S)
¼"FixedMaleFaceSealHighFlowThrough,OrderCode:WM¼"FixedMaleFaceSealHighFlowThrough,OrderCode:WMonlyavailablewithpressurerangesupto25bar/300psi
Page6of12 WIKA Datasheet WU-1X · 2/2013
Specificationsanddimensionsgiveninthisleafletrepresentthestateofengineeringatthetimeofprinting.Modificationsmaytakeplaceandmaterialsspecifiedmaybereplacedbyotherswithoutpriornotice.
FlyingleadsIP65(NEMA4)*)Ordercode:DI
Bayonetconnector4-pin,IP65(NEMA4)*)Ordercode:O4
SUB-D connector15-pin,IP54(NEMA3S)Ordercode:TX
CircularconnectorM 12x14-pin,IP65(NEMA4)*)Ordercode:M4
*)withsideaccessIP54(NEMA3S)
3-wire2-wireDimensions in inch [mm]
red red
black
brown
black
Dimensions and wiring details WU-1X IngressProtectionIPperIEC60529
Page7of12WIKA Datasheet WU-1X · 2/2013
WU-10 Smart Codes for Custom Order Configurations Field No. Code Feature
Signal Output A 4...20mA,2-wire F 0...10V,3-wire 1 G 0...5V,3-wire Unit B bar P psi 3 psiabsolute 2 ? other (MPa, kPa, kg/cm2, etc.) Pressure Range CH -1...+3bar1) -30inHg...100psi CT -1...+6bar CL -1...+9bar CP -1...+15bar CQ -1...+25bar CX -1...+40bar -30inHg...500psi CY -1...+60bar C1 -1...+100bar C2 -1...+160bar C3 -1...+250bar BG 0...4bar1) 0...160psi EF 0...7bar BI 0...10bar 0...300psI BK 0...16bar BL 0...25bar BM 0...40bar BN 0...60bar 0...1000psi BO 0...100bar 0...1500psi BP 0...160bar 0...2000psi BQ 0...250bar 0...3000psi BS 0...400bar 0...5000psi CE -30inHg...45psi1) CF -30inHg...60psi1) CK -30inHg...160psi CI -30inHg...250psi CM -30inHg...300psi BE 0...60psi1) BF 0...100psi DG 0...250psi DI 0...500psi 3 ?? other
1)Accuracy1.0%ofspan
Page 8 of 12 WIKA Datasheet WU-1X · 2/2013
WU-10 Smart Codes for Custom Order Configurations (continued)
Field No. Code Feature
1)Accuracy1.0%ofspan
12345678910*WU-10 - - - - B G - Z
*Additionalorderdetails
OrderCode:
Process Connection WR ¼"T-connector(1"version) 71 OriginalVCR-malenutSS4-VCR-4 (FSM) 72 OriginalVCR-unionnutSS4-VCR-1 (FSF) 4 ?? other Dampening Z Without 5 A >100ms always with side access Electrical connection M4 4-pinlockingplugM12x1 DI flyinglead,IP65 O4 4-pinbayonetconnector (Bendix) 6 ?? other Cable Length Z Without always choose if plug version E 3 m 7 ? other Special Design Features Z Without 8 1 Zeropotentiometerwithsideaccessalways choose with dampening Additional Order Info9 1 qualitycertificate 10 T additionaltext
Page9of12WIKA Datasheet WU-1X · 2/2013
WU-15 Smart Codes for Custom Order Configurations Field No. Code Feature
Signal OutputA 4 ... 20 mA, 2-wireF 0 ... 10 V, 3-wire
1 G 0 ... 5 V, 3-wireUnit
B barP psi? other (MPa, kPa, kg/cm2, etc.)
2 3 psi absolute Pressure RangeCH -1 ... +3 bar1) -30 inHg ... 100 psiCT -1 ... +6 barCL -1 ... +9 barCP -1 ... +15 barCQ -1 ... +25 barCX -1 ... +40 bar -30 inHg ... 500 psiCY -1 ... +60 barC1 -1 ... +100 barC2 -1 ... +160 barC3 -1 ... +250 barBG 0 ... 4 bar 1) 0 ... 160 psi EF 0 ... 7 barBI 0 ... 10 bar 0 ... 300 psiBK 0 ... 16 barBL 0 ... 25 barBM 0 ... 40 barBN 0 ... 60 bar 0 ... 1000 psiBO 0 ... 100 bar 0 ... 1500 psiBP 0 ... 160 bar 0 ... 2000 psiBQ 0 ... 250 bar 0 ... 3000 psiBS 0 ... 400 bar 0 ... 5000 psiCE -30 inHg ... 45 psi 1)
CF -30 inHg ... 60 psi 1)
CK -30 inHg ... 160 psiCI -30 inHg ... 250 psiCM -30 inHg ... 300 psiBE 0 ... 60 psi1)
BF 0 ... 100 psiDG 0 ... 250 psiDI 0 ... 500 psi
3 ?? other
Page 10 of 12 WIKA Datasheet WU-1X · 2/2013
WU-15 Smart Codes for Custom Order Configurations (continued) Field No. Code Feature
1)Accuracy1.0%ofspan
1234567891011*WU-15 - - - - B G - Z
*Additionalorderdetails
OrderCode:
Process Connection VN ¼"weldstub WG ¼"fixedmalefaceseal WM ¼"fixedmalefaceseal,highflow (pressures up to 25 bar/300psi) 71 OriginalVCR-malenutSS4-VCR-4 (FSM) 72 OriginalVCR-unionnutSS4-VCR-1 (FSF) 4 ?? other Outlet Process Connection VN ¼"weldstub WG ¼"fixedmalefaceseal WM ¼"fixedmalefaceseal,highflowthrough(pressures up to 25 bar/300psi) 71 OriginalVCR-malenutSS4-VCR-4 (FSM) 72 OriginalVCR-unionnutSS4-VCR-1 (FSF) 5 ?? other Dampening Z Without 6 A >100ms always with side access Electrical Connection M4 4-pinlockingplugM12x1 DI flyinglead,IP65 O4 4-pinbayonetconnector (Bendix) 7 ?? other Cable Length Z Without always choose if plug version
E 3 m 8 ? other Special Design Features Z Without 9 1 Zeropotentiometerwithsideaccess Additional order info YES NO 10 1 Z qualitycertificates 11 T Z additionaltext
Page 11 of 12WIKA Datasheet WU-1X · 2/2013
WU-16 Smart Codes for Custom Order Configurations Field No. Code Feature
Signal Output A 4...20mA,2-wire F 0...10V,3-wire 1 G 0...5V,3-wire Unit B bar P psi ? other (MPa, kPa, kg/cm2, etc.) 2 3 psiabsolute Pressure Range CH -1...+3bar1) -30inHg...100psi CT -1...+6bar CL -1...+9bar CP -1...+15bar CQ -1...+25bar CX -1...+40bar -30inHg...500psi BG 0...4bar1) 0...160psi EF 0...7bar BI 0...10bar 0...300psi BK 0...16bar BL 0...25bar BM 0...40bar CE -30inHg...45psi1) CF -30inHg...60psi1) CK -30inHg...160psi CI -30inHg...250psi CM -30inHg...300psi BE 0...60psi1) BF 0...100psi DG 0...250psi DI 0...500psi 3 ?? other Process Connection WE MSMC1⅛"SQ WF MSMW1⅛" 4 ?? other Dampening Z Without 5 A >100ms always with side access
1)Accuracy1.0%ofspan
WIKA Instrument, LP1000 Wiegand Boulevard Lawrenceville, GA 30043-5868Tel: 888-WIKA-USA•770-513-8200Fax: 678-739-2569E-Mail: [email protected]/uhp
R
WIKA Datasheet WU-1X · 2/2013Page 12 of 12
Specificationsanddimensionsgiveninthisleafletrepresentthestateofengineeringatthetimeofprinting.Modificationsmaytakeplaceandmaterialsspecifiedmaybereplacedbyotherswithoutpriornotice.
WU-16 Smart Codes for Custom Order Configurations (continued) Field No. Code Feature
1)Accuracy1.0%ofspan
1234 56789 10*WU-16 - - - - B G - Z
*Additionalorderdetails
OrderCode:
Electrical connection M4 4-pinlockingplugM12x1 DI flyinglead,IP65 O4 4-pinbayonetconnector (Bendix) TX 15-pinhighdensitySub-Dplug6 ?? other Cable length Z without (always choose if plug version) E 3 m 7 ? other Special design features Z without 8 1 Zeropotentiometerwithsideaccess Additional order info YES NO 9 1 Z qualitycertificates 10 T Z additionaltext