Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der...

22
tatus ‘Si readout’ TPC at NIKHE NIKHEF Auke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA DAPNIA Maximilien Chefdeville Paul Colas Yannis Giomataris Arnaud Giganon Univ. Twente/Mesa+ Jurriaan Schmitz CERN/Medipix Constm Erik Heijne Xavie Llopart Michael Campbell Thanks to: Wim Gotink Joop Rovenkamp ECFA Workshop Durham 3/9/2004 PhD student per 1/9/04

Transcript of Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der...

Page 1: Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA.

Status ‘Si readout’ TPC at NIKHEF

NIKHEF Auke-Pieter ColijnAlessandro FornainiHarry van der GraafPeter KluitJan TimmermansJan Visschers

Saclay CEA DAPNIA Maximilien Chefdeville Paul ColasYannis GiomatarisArnaud Giganon

Univ. Twente/Mesa+ Jurriaan Schmitz

CERN/Medipix Constm Erik HeijneXavie LlopartMichael Campbell Thanks to:

Wim GotinkJoop Rovenkamp

ECFA Workshop Durham 3/9/2004

PhD student per 1/9/04

Page 2: Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA.

Goals• Gas multiplication GEM or Micromegas foil(s)• Charge collection with granularity matching

primary ionisation cluster spread• Needs sufficiently low diffusion gas• dE/dx using cluster counting?

( M. Hauschild)

• Proof of principle based on existing Medipix2 readout chip

Page 3: Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA.

MediPix2 pixel sensorBrass spacer blockPrinted circuit boardAluminum base plate

Micromegas

Cathode (drift) plane

55Fe

Baseplate

Drift space: 15 mm

With Paul Colas & Ioannis Giomataris:MediPix2 & Micromegas

Very strong E-field above (CMOS) MediPix!

Page 4: Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA.
Page 5: Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA.
Page 6: Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA.

He/Isobutane80/20Modified MediPix

Sensitive area:14 x 14 x 15 mm3

Drift direction:Verticalmax = 15 mm

31 March 2004

Page 7: Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA.

He/Isobutane80/20Modified MediPix

31 March 2004

Page 8: Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA.

He/Isobutane80/20Modified MediPix

31 March 2004

Page 9: Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA.

He/Isobutane80/20Modified MediPix

δ-ray?

31 March 2004

Page 10: Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA.

Example of a track reconstructed

This track:

•#hits = 24

•#clusters = 11

•length (3d) = 16.8 mm

•1.4 e-/mm; 0.65 cl./mm On average:•1.8 e-/mm; 0.5 cl./mm

Page 11: Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA.

Detection of single electrons using MediPix2/Micromegas assembly as Direct Pixel Segmented Anode

• Analysis of cosmic data 31/3-2/4 finalised

• NIM paper submitted 31/8/04

• #pixels hit/mm track length = 1.83

• #clusters/mm track length = 0.52

• Single electron efficiency 0.9

• Moire effects: mismatch in pixel and hole pitch: 60/(60-55) = 12 pixels repetition

Page 12: Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA.

Non Modified Modified

Explanation for Moire effect: pitch Micromegas holes: 60 μm pitch MediPix pixels: 55 μm

Periodic position of hole w.r.t. pixel: repeats after 12 pixels!

Page 13: Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA.

Modified

Non Modified

InGrid: perfect alignment of pixels and grid holes!Small pad: small capacitance!

Page 14: Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA.

Integrate GEM/Micromegas and pixel sensor

‘GEM’ ‘Micromegas’

By ‘wafer post processing’

InGrid

Page 15: Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA.

Wafer dia.: 100 mm

30 fields with variety of pillar geometry

First trials with pillars look OK

Some problems with ‘Micromegas’ grid

(hope to have first sample in few weeks

Page 16: Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA.

INGRID: some first trials

Various pitches, shapes

Page 17: Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA.
Page 18: Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA.

Other applications of TimePixGrid:

- μ-TPC (e.g. KABES in NA48/3 ?)

- upgrades of TPCs: STAR, ALICE

- Transition Radiation Detectors

- GOSSIP: tracker for intense radiation environment

Page 19: Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA.

CMOS pixel array

MIP

Micromegas

GOSSIP: Gas On Slimmed SIlicon Pixels

Drift gap: 1 mmMax drift time: 10 ns

MIP

CMOS pixel chip

Cathode foil

Page 20: Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA.

Essentials of GOSSIP:

• Generate charge signal in gas instead of Si (e-/ions versus e-/holes)•Amplify # electrons in gas (electron avalanche versus FET preamps)

Then:• No radiation damage in depletion layer or pixel preamp FETs• No power dissipation of preamp FETs

GOSSIP: 1 mm gas layer + 20 μm gain gap + CMOS (digital!) chipAfter all: it is a TPC with 1 mm drift length (parallax!)

Max. drift length: 1 mmMax. drift time: 10 nsResolution: 0.1 mm 1 ns

Page 21: Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA.

EfficiencyPosition resolutionRate effectsAgeingRadiation hardnessHV breakdownsPower dissipationMaterial budget

More details in http://www.nikhef.nl/~d90/tesla/NIPHAD_GOSSIP.ppt

Page 22: Status ‘Si readout’ TPC at NIKHEF NIKHEFAuke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Saclay CEA.

Ongoing/Coming activities:

•Cosmic trigger setup ready

•New Micromegas available very soon (Paul C.)

•New Medipix2 available

•First Ingrid1 tests

•Simulations

Longer term:

•Ingrid2 together with MediPix

•Development of Timepix1 (for TPC) and Timepix2 (for GOSSIP) CMOS chips

New collaborators are welcomed!