starter guide
description
Transcript of starter guide
5Asia & Paci�c
Europe
North America
WireXpertstarter guide
To view results, double click on the cable label of the result to be viewed. and the plot
window will open up with detailed plots.
To print a PDF report of the test result click on the print icon on the top left corner of the
plot window and a print dialog box is launched. Please choose the printer to be your
default pdf writer and generate professional reports for the test.
Importing Test Results
Viewing Test results
1. Create a new project
2. Import Test results from flash drive
3. Choose the flash drive with the test results if you have multiple flash drives inserted in
the PC and click on “import”.
Psiber Data Pte. Ltd.
9 Jurong Town Hall Road
#03-05, iHUB
Singapore 609431
Telephone: +65-6569-6019
Fax: +65-6569-6019
E-mail: [email protected]
www.psiberdata.com
SINGAPORE
Psiber Data GmbH
Felix-Wankel-Str. 4
82152 Krailling
Telephone: +49-(0)89-89136060
Fax: +49-(0)89-89136066
E-mail: [email protected]
www.psiberdata.com
GERMANY
Psiber Data Systems Inc.
7075-K Mission Gorge Road
San Diego, CA 92120
Telephone: +1-619-287-9970
Fax: +1-619-287-9978
E-mail: [email protected]
www.psiber.com
UNITED STATES
Psiber Italy
Via Gaslini
20052 Monza (MI)
Telephone: +39-039-2844287
Fax +39-039-2844286
E-mail: [email protected]
www.psiber.it
ITALY
United Kingdom
Psiber Data Ltd.
Unit 14
New House Business Centre
Old Crawley Road
Faygate
West Sussex
RH12 4RU
Telephone: +44-(0)1293-852306
Fax: +44-(0)1293-852298
E-mail: [email protected]
www.psiber-data.co.uk
UNITED KINGDOM
The WX4500-FA WireXpert kit comes with all the accessories necessary perform acertification test upto CAT6A or Class EA limit in either channel and permanent linkconfiguration. Additionally if you purchased Fiber certification or CLASS FA certificationoptions you will also be provided with additional equipment. A calibration certificate with the date of calibration and validity guarantees accuracy of measurements on your WireXpert for that period. Even though the local and remote units are exactly identical for convinience, the test results are stored only in the local unit.
WireXpert (Local and remote)
CAT6A Channel Adapters
CAT6A Permanent Link Adapters
USB Flash drive
Kit contents
Headset
12V DC Power Adaptors
Soft-case
Calibration Certi�cate
3. Choose the flash drive with the test results if you have multiple flash drives inserted in
the PC and click on “import”.
Power ON/OFF Button
Speaker
Mic / HeadphoneUSB Host Port
R 10/100 Ethernet Port
DC Input
2 3 4
Exporting Test Results
Performing AutoTestSetting up AutoTestGetting Started
Setup
WireXpertstarter guide
REPORTXPERT
Insert a USB flash drive into the host USB port of the “LOCAL” WireXpert.
The user interface will guide you through the copying process for test results into the flash
drive
ReportXpert software is the PC based software that allows you to manage data from
different projects and prepare job reports in pdf format. The installation executable is
located in the USB flash drive that is supplied with the standard kit. After installing the
software on a PC, run the software from the desktop shortcut. To upload test results from
the device into the PC, create a new project from the splash screen. Select “Import Test
Results” from the tools menu and select the flash drive with the test results to complete
uploading.
Installation
Once WireXpert has been setup correctly to perform a certification, Autotest can be
started by clicking on the Autotest button. Once the test is complete, the WireXpert will
show a summary result screen with PASS/FAIL result. The tests can be initiated or saved
from either units, local or remote. But the actual data resides only in the local unit only and
it is sufficient to copy the results from the local unit irrespective of which unit the SAVE is
initiated from.
Autotest and Saving Results
WireXpert allows you to perform both permanent link and channel configuration tests on
any link. Before performing the autotest WireXpert needs to be setup with the appropriate
limits and test configuration, either channel or permanent link. The setup can be done
from the SETUP menu under the “Test Settings” tab as shown below.
To power ON WireXpert Press the power button for 2 seconds
To power OFF WireXpert press the power button for 5 seconds
Most of the WireXpert configuration can be changed at either the Test Settings page or the
System settings page.
Though the local and remote WireXperts are exactly identical interms of hardware the
functionality is slightly different between them in two ways. Only the local unit can display
graphical plots. Secondly, all the test results are always stored in the local unit. The unit
can be identified to be a local or a remote unit by looking at the top left corner of the user
interface display.
Powering ON and Off
LOCAL and REMOTE units
WireXpert significantly reduces the cost of
ownership by using a modular test head
solution for Permanent Link Adapters.
When the kit is shipped to you the test
cord and the adapter are packed
separately. Please insert and test cord into
the Permanent Link adapter as shown in
the figure to perform Permanent Link
configuration tests.
Permanent Link Adapters
Setting Limits
To select the appropriate cable that is being installed, from the “Test Settings” tab click on
the cable manufacturer and select the appropriate cable manufacturer as shown.
Selecting Cable Manufacturer
AutoTest Summary Save Dialog SaveAUTOTEST
Permanent Link Testing
Local Certifier40G Remote Certifier40G
Permanent Link adapter Permanent Link adapter Patch Chord Patch ChordC C
Channel Test
Local Certifier40G Remote Certifier40G
C C
Test Settings Limit Select LimitSETUP
Test Settings Cable Manufacturer Select CableSETUP