Presentation

UNINTERRUPTIBLE POWER SUPPLY

(UPS)

On

Page 4: Rajesh ppt 1

CONTENTS INTRODUCTION

PARTS OF UPS SYSTEM

BLOCK DIAGRAM

WAVEFORMS

TYPES

APPLICATIONS

DIFFERENCE B/W UPS & INVERTER

Page 5: Rajesh ppt 1

INTRODUCTION

UNINTERRUPTIBLE POWER SUPPLY is a device that provides battery backup when the power fails or drops to an unacceptable voltage level

The Switchover time must be small (2 to 4 ms) enough to not cause break in the operation of the loads.

Page 6: Rajesh ppt 1

PARTS OF UPSUPS SYSTEM contains the following parts :- CHARGER CARDBATTERYINVERTER CARDDISPLAY CARDEMI FILTERSTABLIZERBUZZERFAN

Page 7: Rajesh ppt 1

CHARGER CARD:- It consists of a rectifier which converts AC in to DC to charge the Battery.

Input Output Main AC supply DC

.

RECTIFIREBATTE

RY

Page 8: Rajesh ppt 1

INVERTER CARD:- It converts the DC into AC.

INVERTERBATTER

YDC AC

Page 9: Rajesh ppt 1

EMI Filter:- An EMI (Electromagnetic Interference) filter helps to reduce spikes and electrical noise.

INVERTER

EMI Filter

AC with Noise & spikes

Pure AC

STABLIZER:-Regulates the voltage to the constant range that is safe for the loads.

Page 10: Rajesh ppt 1

DISPLAY CARD & BUZZER :-

•LEDs are used to indicate the user about the UPS status. Status :- overloading, charging ,online/ offline.

•BUZZER is used to give warnings like: FAN:-

It is used for the cooling of UPS System.

Low batteryOverloading

Page 11: Rajesh ppt 1

BLOCK DIAGRAM

RECTIFIER

INVERTER

EMI Filter

BATTERY

STATIC SWITCHS

S1

STATIC SWITCH

S2

LOAD

UPS SYSTEM

BUZZER

Bypass AC

Main AC

DC ACPURE

AC

S2 : ONWhen mains fails

Page 12: Rajesh ppt 1

UPS WAVEFORMS

TRUE SINEWAVE

MODIFIED SINEWAVE

SQUARE WAVE

Page 13: Rajesh ppt 1

UPS WAVEFORMS

-170

0

170

0 4 8 12 16 20

TIME (ms)

VO

LT

AG

E

TRUE SINEWAVEMODIFIED SINEWAVESQUARE WAVE

Page 14: Rajesh ppt 1

ON-line UPS:-1.In ON-Line UPS INVERTER Card is always active.2.Static Switches S2 :- Always ON S1 :- generally OFF. When inverter fails: S1:- ON.

3. There is zero switchover time.OFF-Line UPS:-1.Input is directly connected to Output.

2.Switches S1: Normally ON S2: OFF when mains fails: S2: ON

3.There is switch over time of 2 to 4 msec.

TYPES

Page 15: Rajesh ppt 1

RECTIFIER

INVERTER

EMI Filter

BATTERY

STATIC SWITCHS

S1

SWITCH S2

LOAD

Bypass AC

Main AC

DC ACPURE

AC

The ON-line OFF-Line UPS can be explained with the help of this block diagram:-

Page 16: Rajesh ppt 1

APPLICATIONS:-

UPS generally used , where data loss causes a serious problem like in:-

ComputersOperation TheatersBanks Control Room applications

Page 17: Rajesh ppt 1

DIFFERENCE B/W UPS & INVERTER

UPS INVERTER

It has high switching speed & very low switchover time(2 to 4 ms).

It is used for computer applications.

Output is sine wave.

It has low switching speed & high switch over time (20 to 40 ms)

It is used for home appliances like TV , Fan , Tube-light etc.

Output is square wave.