Protective clothing for firefighters TIGER Plus · Protective function of the clothing and a list...

14
Protective clothing for firefighters TIGER Plus Type No: 658-1026 3rd category of Personal Protective Clothing 1 11/2019

Transcript of Protective clothing for firefighters TIGER Plus · Protective function of the clothing and a list...

Page 1: Protective clothing for firefighters TIGER Plus · Protective function of the clothing and a list of harmonized norms: The clothing serves as a protection of fire fighter’sbody

Protective clothing for firefighters

TIGER PlusType No: 658-1026

3rd category of Personal Protective Clothing

1

11/2019

Page 2: Protective clothing for firefighters TIGER Plus · Protective function of the clothing and a list of harmonized norms: The clothing serves as a protection of fire fighter’sbody

2

Design: ELITE - Jacket

Page 3: Protective clothing for firefighters TIGER Plus · Protective function of the clothing and a list of harmonized norms: The clothing serves as a protection of fire fighter’sbody

3

Design: ELITE - trousers

Page 4: Protective clothing for firefighters TIGER Plus · Protective function of the clothing and a list of harmonized norms: The clothing serves as a protection of fire fighter’sbody

4

Design: PREMIUM - jacket

Page 5: Protective clothing for firefighters TIGER Plus · Protective function of the clothing and a list of harmonized norms: The clothing serves as a protection of fire fighter’sbody

5

Design: PREMIUM - trousers

Page 6: Protective clothing for firefighters TIGER Plus · Protective function of the clothing and a list of harmonized norms: The clothing serves as a protection of fire fighter’sbody

6

Used materials and their technical parameters:

Material assembly:

Outer material: NOMEX®Diamond Ultra, 210g/m2

(98% aramid/2% antistatic fibre, finish SOFIGUARD

Performance)

Membrane: Fireblocker N 2L, 140g/m2

(face: non-woven fabric, 100% Aramid back: bicomponent membrane based on PTFE)

Lining: NOMEX® Comfort, Aramid Grid, 200g/m2

(93% m-aramid / 5% p-aramid / 2% P140, grid 100% aramid)

Reflective material: 3M™ Scotchlite™ 9687 (yellow-silver-yellow)3M™ Scotchlite™ 9686 (orange-silver-orange)3M™ Scotchlite™ 5697 (yellow-silver-yellow)3M™ Scotchlite™8987 – yellow3M™ Scotchlite™8940 - silverReflexite 1200 Fire Tape - yellowCoats Signal C412300

Design: jacket + trousers

Page 7: Protective clothing for firefighters TIGER Plus · Protective function of the clothing and a list of harmonized norms: The clothing serves as a protection of fire fighter’sbody

7

Clothing impregnation

• Top material is equipped by a sufficient impregnation SOFIGUARDPerformancethat secures protection against water and chemicals. The producer of the materialguarantees min. 25 cycles before any re-impregnation when the launderinginstructions are followed.

• Impregnation efficiency in real conditions may differ from the measured laboratory results and is influenced by several factors.

• Keep your garment clean. • For recovery of the treatment we recommend additional drying in the tumbler at

temperature 70 °C for 15 minutes ! Perform the additional drying on closedgarment from the face side after each maintenance (washing + drying).

Protective function of the clothing and a list of harmonized norms:

The clothing serves as a protection of fire fighter’s body during fire-fighting andduring associated activities with an exception of the actions with a presence ofchemicals or gases (it only covers a possibility of accidental sprinkle by chemical orflammable liquids).

The clothing can be also used as a part of complete grounded system in order toavoid any inflammable discharges (with an exception of environment withatmosphere enriched by oxygen and protection against electric voltage indistribution networks).

Jacket protects against thermal hazards of an electrical arc class 2 (but not againstelectric shock hazards)

The clothing is also used for the protection against unfavourable weather (forexample rain, snow), fog and earth water content.

The clothing protects upper as well as bottom part of body, including neck, arms upto wrists and legs up to ankles according to the above-described standard. Theclothing in combination with other protective measures – safety helmet, gloves,hood, and shoes - provides a complex protection of fire fighter against risksdetermined in the respective standards:

Page 8: Protective clothing for firefighters TIGER Plus · Protective function of the clothing and a list of harmonized norms: The clothing serves as a protection of fire fighter’sbody

8

ČSN EN ISO 13688:2014 Protective clothing – General requirements(EN ISO 13688:2013)

ČSN EN 1149-5:2008 Protective clothing – Electrostatic properties( EN 1149-5:2008)

ČSN EN 469:2015/A1:2015/Opr. 1:2015 Protective clothing for firefighters.Requirements and test methods for protective clothing for firefighters

(EN469:2005/A1:2006/AC:2006)

Level of protection – achieved effectiveness of protective clothing

Heat transfer - flame - level 2Heat transfer – radiation - level 2Resistance to water penetration - level 2Water vapour resistance - level 2

level 1 – lower level of technical use (technical intervention – car accidents and so on)level 2 – higher level of technical use (fire fighting in closed place)

Prediction of burn injury according to ISO 130506

✓ 2nd burn degree - 5,3%✓ 3rd burn degree - 1,8 %✓ Total burn prediction area (2nd and 3rd degree) – 7,1 %

Test report with results of „ Prediction of burn injury using an instrumented manikin” is on request at producer

Page 9: Protective clothing for firefighters TIGER Plus · Protective function of the clothing and a list of harmonized norms: The clothing serves as a protection of fire fighter’sbody

9

ČSN EN 343:2004+A1:2008/Opr. 1:2010 Protective clothing – Protection againstrain

Level of protection – achieved effectiveness of protective clothing

Resistance against water penetration- level 3Water vapour resistance - level 3

(EN343:2003+A1:2007/AC:2009)

IEC 61482-2:2009 Protective clothing against the thermal hazards of anelectric arc

Resistance to thermal hazards of an electric arc – box test:

➢ Class: 2➢ Prospective electric arc current: 7 kA➢ Arc duration: 500 ms➢ Voltage: 400 V

EU – Declaration of conformity: www.deva-fm.cz/ - products-instruction

Clothing service life

Duration of the protective clothing using is not fixed. Expected service life is within therange from 4 to 7 years in case of average utilization. It is protective clothing whichmeans that it can be damaged during some working activity. In such case the followingsteps have to be done:• Clean the clothing according to the instructions• Ensure skilled revision of the clothing by a responsible person (producer, skilled

distributor, or skilled person of a particular fire station)• In case of need repair it (to ensure safety the clothing should be repaired at the

PRODUCER or a trained person)• In case of excessive damage and failure of the protective properties of the

clothing when the repair is not worthwhile, we recommend to put out of use

Page 10: Protective clothing for firefighters TIGER Plus · Protective function of the clothing and a list of harmonized norms: The clothing serves as a protection of fire fighter’sbody

10

Maintenance:

Iron at maximal temperature 110 °C, carefully with steam.

• Maximum wash temperature set at 60 °C with reduced mechanical action• We recommend delicate washing at 40 °C. Temperature of 40°C is suitable as well

for very dirty clothing.• All closures (zippers, press buttons, velcros, buttons, carabines) must be properly

closed to avoid abrasion• Before washing and drying is necessary to remove neoprene knee pads and braces!• PH of washing bath must not be higher than 9.• Do not use detergents with bleaching effects.• Optimal level of machine loading is 2/3, with maximum possible water level and

lower spinning speeds.• If the garment has removable insert, always wash the outer parts separately from

inserts. If inserts are not soiled, remove them and wash just the outer parts toprevent unnecessary wear of moisture and thermal barrier.

• Do not use any softeners!

• Line dry is optimal• Using a tumbler dryer, dry at higher temperature. We recommend drying in two

cycles (face and back sides) 2 x 45 minutes.• A dryer should be filled at 2/3 of its capacity. (f.e. for drum of 13 kg put dry garments

with weight of 10 kg)• If the garment is damp, we recommend to hang it to dry• To recover the treatment we recommend additional drying at 70 °C for 15 minutes!!

Perform the additional drying on closed garment from the face side after eachmaintenance (washing + drying).

Page 11: Protective clothing for firefighters TIGER Plus · Protective function of the clothing and a list of harmonized norms: The clothing serves as a protection of fire fighter’sbody

11

Do not Bleach !

The product can be cleaned by tetrachlorethen, monofluortrichlormethanand all dissolution reagents stated under a symbol F. Usual cleaning steps are without a limitation

Professional wet cleaning. Ordinary cleaning procedures.

Decontamination (Disinfection) :

• Intervention clothing infected by biological material must be treated with hydrogenperoxide and peracetic acid-based concentrates activated during machine washing.

• Do not use chlorine-based products.• Recommended disinfection agents are suitable for white, as well as color textiles,

except wool and silk. Their utilization is in accordance with European microbicidestandards EN 1650 and EN 14476.

• Disinfection agents are effective at 40 °C and a longer washing cycle of at least 20minutes.

• The exact dosage will be specified by your chemicals supplier based on theintervention clothing types.

Finally we would like to draw your attention to a fact that material NOMEX® is as otherchemical materials with high share of paraaramide sensitive to direct daylight. Toeliminate mechanical and visual abrasion of the outer material of the garment it isessential to observe right laundering procedures, eventually timely done re-impregnation. We are absolutely convinced that the most sensitive part at laundering isthe time, the temperature and loading of the washing and drying process. We can saythat excessive temperature and over drying can result in excessive shrinkage.We absolutely recommend keeping an evidence list of the clothing service andmaintenance (Appendix 1 – see our web pages).

Page 12: Protective clothing for firefighters TIGER Plus · Protective function of the clothing and a list of harmonized norms: The clothing serves as a protection of fire fighter’sbody

12

Washing and decontamination agents that can be used for intervention clothing are in the chart bellow:

Storage:

• Storage of the clothing does not require any special conditions.• Protect the clothing against direct sunlight and UV radiation.

Packing:

• Plastic bag, paper box

For medium to highly contaminated protective garment by oils, petroleum, paints,and biological substances (proteins, blood etc.) we recommend to entrust the maintenanceto a professional laundry.

Page 13: Protective clothing for firefighters TIGER Plus · Protective function of the clothing and a list of harmonized norms: The clothing serves as a protection of fire fighter’sbody

13

Instructions for users:

EN 469:2005• In compliance with EN 469 requirements, the lower and upper body parts,

including a neck, arms to wrists, and legs to ankles are protected and covered bythe clothing; however, the other body parts are not protected and otherequipment items are necessary to achieve the complete protection.

• In case of accidental stain by a liquid chemical substance or flammable liquidduring the wear at a place with a fire and/or heat exposure immediately leavethe place, take the clothing off and clean it, possibly do not use anymore and putit out of service.

EN 1149-5• A person wearing protective clothing that dissipates static electricity charge must

be properly grounded. Resistance between such person and ground must be lessthan 108 W, by using, for example, proper footwear.

• The clothing must not be unfastened or removed near flammable or explosiveenvironment or when working with flammable or explosive agents.

• The clothing must not be used in the oxygen-enriched atmosphere without aprior approval of a responsible safety technician.

• The clothing's static electricity protection properties could be affected by itswear, tear, washing, and soiling.

• When in use, the static electricity dissipating protection clothing must constantlycover all materials that do not have such properties. All closing elements must beproperly closed!

IEC 61482-2 – class 2• When using this clothing as a protection against the thermal hazards of an

electric arc it´s necessary to consider actual working conditions. Differences fromparameters specified in IEC 61482-3 can cause serious circumstances.

• The clothing in combination with other protective measures – safety helmet,gloves, hood, and shoes - provides a complex protection of fire fighter againstrisks.

• The protective clothing can be ONLY used as upper part on foundationgarment. Foundation garment which melts during heat flux of electric arcMUST NOT be used which means foundation garment made of artificial fibres,e.g. polyamide, polyester, acryl. We recommend using underwear made ofNOMEX.

• The protective properties may be influenced by the conditions andcontamination of garment, which may cause reduction of the protective functionagainst effect of electric arc.

Page 14: Protective clothing for firefighters TIGER Plus · Protective function of the clothing and a list of harmonized norms: The clothing serves as a protection of fire fighter’sbody

14