PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS...

35
PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the discretion of ACT2 Technologies, LLC 3m³ to 12m³

Transcript of PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS...

Page 1: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant

Presented by

32m³ & 60m³

12m³ to 24m³ 24m³

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

3m³ to 12m³

Page 2: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

PIRANHA WASTEWATER SYSTEMS

3m³ to 12m³

32m³ & 60m³ 12m³ to 18m³ 24m³

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

Photos of Actual Piranha Systems at the ACT2 Test facility near Cape Canaveral Florida

Page 3: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

PIRANHA WASTEWATER SYSTEMS (Some of our Vessels that Operate in Sensitive Waters)

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

Page 4: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

PIRANHA WASTEWATER TREATMENT and WATER RECLAMATION SYSTEMS

True “Toilet to Tap”

Raw

Sewage

Piranha

Effluent

City

Water

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

Page 5: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

PIRANHA WASTE to WATER

How Does it Work?

• Holding Tank

• Patented Aerobic/Anaerobic process to consume human

waste

• Siemens PLC “Controlled Biomass”

• Biological Degradation of Byproducts • Mostly H₂O • CO₂ • N₂ Gas +N₂ Compounds (ammonia, nitrites, nitrates) • Organic and Inorganic macro and micro nutrients

BIOLOGICAL BASED WASTEWATER TREATMENT SYSTEMS

ARE THE MOST COST EFFECTIVE & UNDERSTOOD

PROCESSES IN THE WASTEWATER TREATMENT

INDUSTRY.

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

Page 6: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

PIRANHA WASTE to WATER

• Biomass is separated by Polymer

• Continuous Maceration of Biomass

• Clean water is removed from upper layer

• Water (supernatant) is sent to Piranha for de-contamination

• Suspended Solids are removed and sent to Holding Tank

• Digestion continues…

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

Page 7: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

THE PIRANHA WASTEWATER SYSTEMS

Macerator and

Aeration Pump

Influent Transfer

Pump to Piranha

TSS Return

from Piranha

Raw

Sewage

Supply

Line

Holding Tank

(simulated)

Biomass Tank (Holding Tank)

First Stage:

• Maceration/Aeration

• Separation

• Digestion (sludge to water)

Biomass

(sludge)

Supernatant

(Digested Waste)

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

Actual Sample taken from a holding tank

(Raw sewage: courtesy of the Cocoa Beach Florida WTP influent supply line)

Page 8: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

PIRANHA WASTE to WATER

• Piranha uses all proven technology

• First process is known as a Lamella Clarifier

• Second process is known as a DAF (Dissolved Air Flotation)

• Suspended Solids are skimmed and sent to Holding Tank

• Clean water is then sent through the UF (Ultra Filtration)

• All contaminants, coliform bacteria, viruses, suspended

particles, organisms and compounds larger than 150,000

Daltons (~0.08 microns) are removed.

• Optional NANO Filtration (fresh water reverse osmosis) is

used for any remaining contaminants down to ~0.02 microns.

• Both UF and NANO filters are automatically back-flushed to

send contaminants back to the Holding Tank.

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

Page 9: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

THE PIRANHA WASTEWATER SYSTEMS

Biomass Tank

Second Stage:

• Separation of Solids

• Ultra Filtration

• Optional Reverse Osmosis (NANO)

Potable Water for

Reuse

Lam

ella

& D

AF

0.0

8 M

icro

n

Filt

ratio

n

Re

ve

rse O

sm

osis

(NA

NO

Filt

ration)

Piranha System and Biomass (Holding) Tank

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

Page 10: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

Gravity

INFLUENT

VENT

Vacuum

INFLUENT

ACT2

Sensors

Suction Line

Return

Optional

Reuse

Tank

Overboard

Discharge

Vessel

Holding/Aeration

Black/Grey Tank

Piranha Supplied

PIRANHA WRS-XX

Unit • Laundry and Grease Traps are required but not shown.

• Shipyard Supplied Tank and Piping in Red (Optional Holding Tank Can be Supplied)

• Optional Re-Use Water Storage in Blue

THE PIRANHA WASTEWATER SYSTEMS

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

(WRS-3 Shown)

Page 11: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

SYSTEM PROCESS

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

Page 12: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

PIRANHA WATER QUALITY SEWAGE WASTE TO REUSABLE WATER

ARRV SIKULIAQ

National Science

Foundation

(98% Water Reuse)

Actual photos from Factory

Acceptance Testing

See Separate Lab Results

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

Page 13: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

PIRANHA CONTAINERIZED SYSTEM CONTAINERIZED WASTE TREATMENT SYSTEMS

Self Contained IMO/MEPC &

USCG 227(64) Certified Marine

Sanitation Devise (MSD) for the

Transocean Oil Rig, RATHER

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

Page 14: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

PIRANHA SYSTEM WASTE TREATMENT SYSTEMS

Small Compact Self Contained

Units for up to 30 people. (Discoverer Enterprise)

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

Page 15: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

THE PIRANHA WASTEWATER SYSTEMS

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

Marine MSD, Landfill Leachate, Laundry Water Reuse, Hog/Dairy Farms…

Page 16: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

PIRANHA STAND-ALONE SYSTEMS

Piranha System with Holding Tanks

for 60 persons (black and gray water)

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

Page 17: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

Small Closed Treatment System 90 Gallon Black Water Tank on DOD Mobile Unit

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

Department of Defense (DOD) Unit

Page 18: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

PIRANHA RESTROOM FACILITIES (CLOSED LOOP TRAILER UNITS)

TURNING WASTE BACK INTO RE-FLUSHING WATER

(Chemical Warfare Research Lab)

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

For US Army Dugway Proving Grounds

Self-Contained Zero

Discharge Restroom Trailer

Department of Defense

(DOD) Interior shots are classified

Page 19: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

PIRANHA RESTROOM FACILITIES (CLOSED LOOP CONTAINERIZED UNITS)

TURNING WASTE BACK INTO RE-FLUSHING WATER

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

Page 20: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

SIZES

SIZES

SIZES

Page 21: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

L= 1,3650mm

W= 920mm

H= 1,450mm

MODEL A

3mᶟ/day to

12mᶟ/day

Membrane Location Can Change

Page 22: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

L= 1,500mm

W= 920mm

H= 1,500mm

MODEL B

12mᶟ/day to

24mᶟ/day

Membrane Location Can Change

Page 23: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

L= 2,718mm

W= 1,473mm

H= 2,108mm

MODEL C

24mᶟ/day to

32mᶟ/day

Membrane Location Can Change

Page 24: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

L= 2,933mm

W= 1,728mm

H= 2,134mm

MODEL D

40mᶟ/day to

60mᶟ/day

Membrane Location Can Change

Page 25: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

Comparable Capacity Competitor and PIRANHA

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

Page 26: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

Comparable Capacity Competitor and PIRANHA

Optional JETS Pumps

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

Page 27: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

Page 28: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

MEPC/USCG 227(64)

CERTIFICATIONS

NOTE: No System Modifications were Required to Pass

the New 227(64) Standards.

Page 29: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

TEST DATA

Page 30: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

Model A Model B

Page 31: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

Model C Model D

Page 32: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

Unit Installed in 2012

Page 33: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

UNITS BUILT FOR

TRANSOCEAN DRILLING

RIGS and SHIPS

Page 34: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

Leading Edge Technology in Wastewater Treatment and Water Reclamation Systems

____________________________________________________________________________

Preliminary Request for Information

Thank you for your inquiry regarding the ACT2 Technologies Piranha, WRS (Water Reclamation

Systems) units. ACT2 Technologies has 13 different systems from 3m³/day to 60m³/day that are USCG,

IMO/MEPC 227(64) Compliant. These systems can be configured, to a certain extent, to fit in various

vessel locations and spaces.

Please take a few minute to complete our request for information below and we will get back to you as

soon as possible.

Contact Person: _____________________ Position: ___________________________

Contact Info: _________________________________ Vessel Name: _______________________

Builder: _____________________________ Refit/New Build: ____________________

Classification Society: _______________________ Flag: ______________________________

Max Crew: __________ Max Pass: ____________

Central Holding Tank (Y/N): _____ Capacity (m³ or gal): ________ No. of Tanks: ___________

Vacuum or Gravity Feed: _____________________ Gray, Black or Both: ____________

Lint Trap Installed (Y/N): _______ Grease Trap Installed (Y/N): _______

Known or calculated daily average of wastewater discharge: ____________USG or _____________M³

Present System Make: ______________ Model: __________ Capacity: ______________________

Available Footprint and Height in L: _________________ W: _____________ H: ________________

Available Power (3 Phase) Volts: ______________ Amps: _________ Hz: ___________

Will you be reusing the discharge water as Technical Water or other (Y/N)? _____

Will you require a digital or analog output to an existing Vessel Alarm System (Y/N? ________

Will the vessel have the ability to have an internet connection at the Piranha system for real time

troubleshooting, diagnostics and crew training if needed (Y/N)? _________

Thank you for your time,

ACT2 Technologies

Marine System Questionnaire

Page 35: PIRANHA MARINE WASTEWATER SYSTEMS - ACT2 Tech · 2016-09-22 · PIRANHA MARINE WASTEWATER SYSTEMS MEPC 227(64) Compliant Presented by 32m³ & 60m³ 12m³ to 24m³ 24m³ Proprietary

Proprietary Information: This document contains proprietary information. Possession and use is permitted solely at the

discretion of ACT2 Technologies, LLC

ACT2 Technologies Additional Projects and Capabilities

• Hog and Dairy Farm Wastewater Reclamation

• Landfill Leachate Wastewater Reclamation

• Animal Carcass Digestion to Water (100%)

• Disaster Relief Water Purification Units

• RV Zero Dump (discharge) systems

• Runoff Water Filtration

• Nitrogen and Phosphorus Reduction (up to 98%)

• Well Water Purification from Fracking Contamination

• Portable Water Purification Systems

• Portable Water Purification Units

• Portable Sewage Treatment Plants (10mᶟ/2,640gallons/day)

• Closed Loop Water Reclamation Systems

• US Coast Guard/IMO/MEPC Approved Demo Unit on Site (You are invited to see Titusville Sewage Turned into Drinkable Quality Water)

Waste to Water ACT2 Video

ACT2 Technologies LLC, 1355 White Drive, Titusville, FL 32780

+1 (954) 791-1812 / (321) 567-4915 / [email protected]

Video Links