Latar Belakang

Waste Heat Boiler (WHB) merupakankomponen penting bagi proses di pabrik 1(urea)

WHB trip Pabrik 1 shutdown

Latar Belakang

Umur Waste Heat Boiler yang sudah tua

harus dianalisa keandalan Instrumentasinya

Permasalahan

• Bagaimana menentukan tiap-tiap loop pengendalian dalam sistemWaste Heat Boiler PT. Petrokimia Gresik

• Bagaimana menentukan nilai reliability untuk tiap loop pengendalian

• Bagaimana menentukan PFD pada tiap loop pengendalian

• Bagaimana menentukan tingkat SIL pada Waste Heat Boiler PT. Petrokimia Gresik

• Bagaimana menentukan kualitas dari process variable pada Waste Heat Boiler PT. Petrokimia Gresik.

Tujuan penelitian

• Tujuan dari penelitian ini adalah dilakukan analisa kinerja instrumen padaWaste Heat Boiler melalui perhitungan reliability, safety, dan quality danakan dilakukan penentuan nilai Safety Integrity Level-nya.

Batasan Masalah

• Boiler yang dianalisa adalah Waste Heat Boiler PT. PetrokimiaGresik

• Data yang digunakan diperoleh dari data maintenance dan/ataudatabase (OREDA)

• Standard yang digunakan adalah ISA S84.01, IEC 61508, dan IEC 61511

• Hasil penelitian berupa program berbasis Excel yang dapatmenganalisa SIS pada setiap komponen penyusun Waste Heat Boiler

Metodologi Penelitian

STUDI LAPANGAN & PENGAMBILAN DATA LAPANGAN

IDENTIFIKASI INSTRUMEN & KOMPONEN LOOP

PERHITUNGAN FAILURE RATE & DISTRIBUSI DATA

EVALUASI RELIABILITY DENGAN PM

PERHITUNGAN PFD & PENENTUAN SIL

PENYUSUNAN QUALITY CONTROL CHART

KESIMPULAN

PERHITUNGAN MAINTAINABILITY DAN AVAILABILITY

STUDI LITERATUR

Data maintenance

• Didapatkan data maintenance untuk beberapa instrumenWHB.

Tabel tanggal kerusakan

• Untuk instrumen yang tidak diketahui data kerusakannya, maka sebagai gantinya, digunakan data failure rate dari OREDA (Offshore Reliability Data-2002)

Data Proccess Variable

• Data PV merupakan data selama 1 bulan yang didapatkan dariDCS WHB

Data PV

• Data PV ini digunakan untuk membuat grafik quality control.

Studi Literatur

• Reliability :

Probabilitas untuk tidak mengalami kegagalan atau dapatmelaksanakan fungsinya selama periode waktu tertentu.

Keterangan :

– F(t) = Cumulative Distribution Function (CDF)

– R(t) = Reliability Function

– f(t) = Probability Density Function (PDF)

Studi Literatur (lanj.)

• Fase burn-in (DFR)– Diakibatkan kerusakan dalam

manufaktur, retak saatpengelasan, patah, pengendalianterhadap kualitas yang rendah, sertakontaminasi.

• Fase Useful life (CFR)– Diakibatkan oleh lingkungan, beban

yang tidak tetap, kesalahanmanusia, serta kuasa Tuhan

• Fase Wear –out (IFR)– Diakibatkan oleh

kelelahan, korosi, penuaan, gesekan,dan beban yang berulang.

The Bathtub Curve

Studi Literatur (lanj.)

• PFD =– Probabilitas suatu sistem akan

mengalami kegagalan.

• SIL =– Safety Integrity Level

PFDFCE

PFDPLC

PFDSensorLoop SIL equals:PFDFCE + PFDSensor + PFDPLC

SIL = konversi nilai PFD ke tabel

Studi Literatur (lanj.)

• Quality Control Chart– membantu menentukan apakah

proses dalam keadaan terkontrolatau tidak.

LP drum

Loop 1

WHB process

Ammonia

Hydrazine

Condensate

Deaerator

HP drum

Flash VesselBlowdown

Vessel

HP Steam

Burner

Loop 2

Loop 3

Loop 4

Loop 5

Loop 6

Loop 1 - LP Drum Level Control

No Loop

Instrumen Tag Number Location Service Fluide Suplier Type

Body Size

Trim Size

1 LT 22210 LP DrumLP Drum Level

ControlWater/Stea

m Honeywell STD 624 - -

LIC 22210 Control RoomLP Drum Level

Control - Honeywell TDC 3000 - -

LCV 22210 Condensate LineLP Drum Level

Control Condensate Fisher ET (Globe) 4" 4 3/8"

LP DRUM

FROM CONDENSATE PUMP

LT22210

LCV 22210

TO HP DRUM

DEAERATOR

LIC22210

Loop 2 - Deaerator Pressure Control

No Loop

Instrumen Tag Number Location Service Fluide Suplier Type

Body Size

Trim Size

2 PT 22211 DeaeratorDeaerator Pressure

ControlSteam/Wate

r Honeywell STG 644 - -

PIC 22211 Control RoomDeaerator Pressure

Control - Honeywell TDC 3000 - -

PCV 22211Steam to

DeaeratorDeaerator Pressure

Control Steam Fisher EHS (Globe) 1" 3/8"

LP DRUM

DEAERATORPIC22211

PT22211

PCV 22211

FROM HP DRUM

TO HP DRUM

Loop 3 - Steam Temperature Control

No Loop

Instrumen Tag Number Location Service Fluide Suplier Type

Body Size

Trim Size

3 TT 22227 Main Steam LineSteam Temperature

Control Steam Sensycon/Degussa TM110F - -

TIC 22227 Control RoomSteam Temperature

Control - Honeywell TDC 3000 - -

TCV 22227Steam Coolwater

LineSteam Temperature

ControlBoiler

Feedwater Fisher EZ (Globe) 1 1/2" 1/2"

FROM BOILER FEEDWATER PUMP

TCV 22227 HP SUPERHEATER 2

TO HP STEAM HEADER

TT22227

TIC22227

Loop 4 - BFW Flow Control

No Loop

Instrumen Tag Number Location Service Fluide Suplier Type

Body Size

Trim Size

4 LT 22220 HP DrumHP Drum Level

Control Steam Honeywell STD 624 - -

FE 22220 BFW Line BFW Flow WaterSimon Lust

Engineering/SEIKO6"/600# RF Sched 80 - -

FT 22220 BFW Line BFW Flow Water Honeywell STD 120 - -

LIC 22210 Control RoomHP Drum Level

Control - Honeywell TDC 3000 - -FIRC 22220 Control Room BFW Flow - Honeywell TDC 3000 - -

FCV 22220Boiler Feedwater

LineHP Drum Level

ControlBoiler

Feedwater Fisher ET (Globe) 3"2

5/16"

HP DRUM

LT22220

LIC22220

FROM BOILER FEEDWATER PUMP

FT22220

FIRC22220

FY22220

FCV 22220

Loop 5 - Flash Vessel Level Control

No Loop

Instrumen Tag Number Location Service Fluide Suplier Type

Body Size

Trim Size

5 LT 22241 Flash VesselFlash Vessel Level

ControlWater/Stea

m Honeywell STD 624 - -

LIC 22241 Control RoomFlash Vessel Level

Control - Honeywell TDC 3000 - -

LCV 22241 Flash VesselFlash Vessel Level

Control Water Fisher GL (Globe) 1" 0,8"

FLASH VESSEL

FROM HP DRUM

TO LP DRUM

LT22241

BLOW DOWN VESSEL

LCV 22241LIC

22241

Loop 6 – Gas Flow Control

No Loop

Instrumen Tag Number Location Service Fluide Suplier Type

Body Size

Trim Size

6 PT 22226 Main Steam LineMain Steam Line

Pressure Steam Honeywell STG 674 - -

TT 22205Downstream Duct

BurnerExhaust Gas Temperature Exhaust Gas Sensycon/Degussa TM110F - -

PIC 22226 Control RoomMain Steam Line

Pressure - Honeywell TDC 3000 - -

TIC 22205 Control RoomExhaust Gas Temperature - Honeywell TDC 3000 - -

FCV 22253 Fuel Train Flow Control Natural Gas Fisher ED 667 (Globe) 3" 3 7/16

TO HP STEAM HEADER

PT22226

PIC22226

DUCT BURNERTT

22205TIC

22205

FX22223

FUEL GAS SUPPLY

FCV 22253

HP DRUM

Perhitungan Failure Rate & Penentuan distribusidata

• Nilai failure rate dan model distribusi didapatkan denganbantuan software Reliasoftweibull ++7 dan EasyFit 5.2

TTF = TBF - TTR

MTTF = 849,24 hari

LT 22220

Occurrence CompletionTTF TTR

hari hari

01/08/1993 01/08/1993 0 0

06/05/2005 06/05/2005 4293 0,021

19/07/2005 19/07/2005 73,979 0,0625

20/03/2006 20/03/2006 248,9375 0,042

22/11/2006 22/11/2006 249,958 0,0833

12/12/2006 12/12/2006 24,9167 0,0833

01/11/2009 01/11/2009 1053,9167 0,021

Perhitungan Failure Rate & Penentuan distribusidata

• Nilai TTF tadi dimasukkan kedalam software

• Dicari distribusinya

• Didapatkan :

Reliasoft Weibull++7:Lognormal 2 parameter

EasyFit5.2:Gen. Extreme Value 3 parameter

BEDA ???

Perhitungan Failure Rate & Penentuan distribusidata

• Nilai MTTF perhitungan dibandingkandengan MTTF software

• Karena nilai MTTF GEV lebihmendekati MTTF hasilperhitungan, maka model yangdigunakan adalah distribusi Gen.Extreme Value

VALIDASI MODEL DISTRIBUSI

MTTF = 849,24 hari

perhitungan

MTTF Lognormal= 2324,47 hari

MTTF Gen. Extreme Value= 849,23 hari

software

= ?

MTTF

Evaluasi Reliability dengan preventive maintenance

• distribusi exponential λ konstan karakter useful life

• 2 buah instrumen dengan distribusi Gen. Extreme Value dikelompokkan kedalam masa burn-in.

???

• PM masa wear-out

• Masa useful life redundancy

• Masa burn in burn-in testing, QC, screening

Rm(t) < R(t)

T=9

Grafik reliability WHB

tanpa PM

Nilai R:

t =365 hari18%

dengan PMNilai R:t =365 hari 0%

Perhitungan Maintainability dan Availability

• Dihitung juga nilai maintainability danketersediaan masing-masing instrumen

Occurrence CompletionTTF TTR

hari hari

01/08/1993 01/08/1993 0 0

06/05/2005 06/05/2005 4293 0,01

21/03/2006 21/03/2006 318,979 0,042

01/11/2009 01/11/2009 1331,958 0,021

PCV 22211

MTTR = 0,028 hari MTTR

Perhitungan PFD & penentuan SIL

• Didapatkan nilai PFD total = 0,052247 /tahun

• Nilai ini berarti dalam 1 tahun operasiWHB, kemungkinan WHB gagal adalah sebesar 0,052247 kali

• Konversi nilai PFD ke SILdidapatkan nilai SIL 1

PFD WHB

Penyusunan Quality Control Chart

• Penyusunan dilakukan dengan 2cara, dengan menghitung manual, danmenggunakan bantuan sotware Minitab14

74.88

74.9

74.92

74.94

74.96

74.98

75

75.02

75.04

75.06

75.08

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31

Axis

Tit

le

Grafik Quality LC 22210

sample

UCL

LCL

x dbl bar

UCL = 75,0635

Mean = 75,0029

LCL = 74,94231

QC chart

Hasil akhir

• Reliability baik kondisi instrumenpada masa useful life & burn-in

• Process Variable pada WHB dalamkondisi terkendali

• SIL 1 kurang baik, standard boiler adalahSIL 2

Hasil akhir

• Semakin besar nilai Reliability maka nilai PFD akan semakin kecil

• Semakin kecil PFD maka nilai SIL semakin besar

SILPFD

tR 1

)(

Quality PV Good)( tR

Loop 1 Loop 6

Kesimpulan

1. 21 instrumen WHB memiliki karakter CFR sedangkan2 buah lainnya DFR

2. PM tidak cocok untuk WHB, karena PM IFR

3. Untuk1. CFR redundancy

2. DFR burn-in testing, screening, QC, acceptance testing

4. PFD = 0,052247/tahun SIL 1

5. Dari grafik kualitas didapatkan bahwa secarakeseluruhan proses WHB dalam keadaan terkendali

6. WHB cukup baik, target SIL 2