4
NEWS 1 FX3G series expansion — Volume 8 — NEWS 1 FX3G series expansion. NEWS 2 The New GT1030 DC5V Power Supplied FX Series PLC. NEWS 3 Modbus master functionality is now included in GT10 series. NEWS 4 16 GOT1000 Series HMIs Can Now Be Joined Together. NEWS 5 New industrial service device for FX PLC, FX-30P. The FX3G is an introductory compact PLC and is the newest addition to the FX3 series, designed for simple yet performance- critical applications. Incorporating innovative FX3 series technology the customer is presented with a suite of benefits. FX3G-14MT/ES FX3G-14MR/ES FX3G-14MT/ESS FX3G-24MT/ES FX3G-24MR/ES FX3G-24MT/ESS FX3G-40MT/ES FX3G-40MR/ES FX3G-40MT/ESS Transistor Output Sink Relay Output Transistor Output Source FX3G-60MT/ES FX3G-60MR/ES FX3G-60MT/ESS I/O 14 points In 8 / Out 6 I/O 24 points In 14 / Out 10 I/O 40 points In 24 / Out 16 I/O 60 points In 36 / Out 24 3rd generation compact PLC Highly flexible Dual system-bus architecture Control of up to 128 directly connected I/O points, or up to 256 with CC-Link remote I/O’s. Product Details All in one CPU, power supply and I/O. Includes many upgraded features from the FX1N. Most notably the usage of the FX3 series ADP bus system and new expansion boards (BD). Instruction Times Basic Instructions: 0.21μs / instruction (Contact Instruction) Memory 32,000 steps of built-in program memory. EEPROM memory cassette with loader functionality is available. Applicable Standards All products support CE and UL/cUL Large Device Memory Complete Lineup of AC Powered FX3G PLCs! NEW Auxiliary Relays........ 7,680 points Timers .......................... 320 points Counters ..................... 235 points Data Registers .................... 8,000 points Extension registers.......... 24,000 points Extension file registers... 24,000 points Main Units Lineup Transistor Source Output Type main units are now available!

Transcript of FX Customer News Vol 8 - Mitsubishi Electric€¦ · of the FX PLC using cables GT10-C10R4-8P (1m)...

Page 1: FX Customer News Vol 8 - Mitsubishi Electric€¦ · of the FX PLC using cables GT10-C10R4-8P (1m) or GT10-C30R4-8P (3m) Both backlight color options and white frame models are available

NEWS 1 F X 3 G s e r i e s e x p a n s i o n

— Vo l u m e 8 —

NEWS 1 FX3G series expansion.

NEWS 2 The New GT1030 DC5V Power Supplied FX Series PLC.

NEWS 3 Modbus master functionality is now included in GT10 series.

NEWS 4 16 GOT1000 Series HMIs Can Now Be Joined Together.

NEWS 5 New industrial service device for FX PLC, FX-30P.

NEWS 5 N e w I n d u s t r i a l S e r v i c e D e v i c e f o r F X P LC , F X-3 0 P

This unit can perform program uploads/downloads and store up to 15 programs in its internal memory. Keywords can be registered, deleted or canceled in applicable PLCs.

and maintenance tool for all FX Series PLCs. Actual

Size

Compatible with all FX series PLCs.

Max. 21 characters × 8 lines.

Store up to 15 programs

Program monitoring function is available.

The latest firmware can be download.

PLC Program Monitoring,Upload/download

�rmware download

List Monitor Screen

Memory Monitor Screen

USB

USB

The FX3G is an introductory compact PLC and is the newest addition to the FX3 series, designed for simple yet performance-critical applications. Incorporating innovative FX3 series technology the customer is presented with a suite of bene�ts.

FX3G-14MT/ES

FX3G-14MR/ES

FX3G-14MT/ESS

FX3G-24MT/ES

FX3G-24MR/ES

FX3G-24MT/ESS

FX3G-40MT/ES

FX3G-40MR/ES

FX3G-40MT/ESS

Transistor Output Sink

Relay Output

Transistor Output Source

FX3G-60MT/ES

FX3G-60MR/ES

FX3G-60MT/ESS

I/O 14 pointsIn 8 / Out 6

I/O 24 pointsIn 14 / Out 10

I/O 40 pointsIn 24 / Out 16

I/O 60 pointsIn 36 / Out 24

3rd generation compact PLC

Highly �exible

Dual system-bus architecture

Control of up to 128 directly connected I/O points, or up to 256 with CC-Link remote I/O’s.

Product DetailsAll in one CPU, power supply and I/O. Includes many upgraded features from the FX1N. Most notably the usage of the FX3 series ADP bus system and new expansion boards (BD).

Instruction TimesBasic Instructions: 0.21μs / instruction (Contact Instruction)

Memory 32,000 steps of built-in program memory.EEPROM memory cassette with loader functionality is available.

Applicable StandardsAll products support CE and UL/cUL

Large Device MemoryRight side

Complete Lineup of AC Powered FX3G PLCs!

NEW

Auxiliary Relays........7,680 pointsTimers .......................... 320 pointsCounters ..................... 235 points

Data Registers .................... 8,000 pointsExtension registers.......... 24,000 pointsExtension �le registers... 24,000 points

Main Units Lineup

Transistor SourceOutput Type

main unitsare now

available!

The FX-30P is a small, industrial programmingThe FX-30P is a small, industrial programmingand maintenance tool for all FX Series PLCs.

87mm

170m

m

Page 2: FX Customer News Vol 8 - Mitsubishi Electric€¦ · of the FX PLC using cables GT10-C10R4-8P (1m) or GT10-C30R4-8P (3m) Both backlight color options and white frame models are available

Increase Your System Flexibility, Now You Can Connect up to 31 Modbus Devices to One GT10 Series HMI*1

!

NEWS 3

Note: GT Designer2 ver. 2.96A or later is required for connectivity.*1. Refer to the compatibility table for supported products in tech news article -0039*2. Depending on the connected device and communication speed

M o d b u s m a s t e r f u n c t i o n a l i t y i s n o w i n c l u d e d i n G T 10 s e r i e s H M I s

Modbus RTU master functionality is now included in GT10 series HMIs*1. With this, up to 31 compatible Modbus devices such as inverters or temperature controllers can be connected to one GOT.

Maximum cable length: RS-232C=15m*2

RS-485 = 1,200m*2

Maximum communication speed 115.2kbps, depending on the cable length and device

Access to the complete range of devices, according to Modbus speci�cation

ModbusNow Available

1 GOT!Max. 31devices connect to

Max. 1,200m*2

Max. 115.2kbps

Inverter

RS-232C or RS-485

Temp controllerOther Modbus device

NEWS 2

Reduce Setup Time and Cost, Combined Power and Communications Now Available in the GT1030!

NOTE: The DC 5V versions of the GT1030 and GT1020 do not support multi-drop or Modbus master functionality.

T h e N e w G T 10 3 0 D C 5 V P o w e r S u p p l i e d F X S e r i e s P LC

Power and

Communications in 1 cable!

Power and

Communications in 1 cable!

No need for an additional power supply!

Power is supplied through the RS-422 programming port of the FX PLC using cables GT10-C10R4-8P (1m) or GT10-C30R4-8P (3m)

Both backlight color options and white frame models are available

Save time and spend less when installing or con�guring equipment!

The new GT1030 joins the GT1020 with the ability to feed o� of the DC 5V service power supply of the RS-422 communication cable connected to the FX series PLC programming port.

UnitGT1030-LBLGT1030-LWLGT1030-LBLWGT1030-LWLW

Frame ColorBlackWhiteBlackWhite

Backlight

Green/Orange/RedRS-422

White/Pink/Red

PLC Communication

Visualize More Display Options, 16 GOT1000 Series HMIs Can Now Be Joined Together with the Serial Multi-drop Connection Unit!

NEWS 4

Equipped with USB, RS-232, RS-422, RS-485 communication ports enabling 4 channels of communication

Maximum 16 GOT1000 series units

Maximum 500m connection length

16 G O T 10 0 0 S e r i e s H M I s C a n N o w B e J o i n e d To g e t h e r

GOT1000 Series

Serial Multi-drop Connection UnitGT01-RS4-M

Mitsubishi PLCsFX, A, QnA, Q series

GOT hardware versions with Multi-drop support is required

Ever wished to increase your connection distance or expand the number of GOTs in your system? Now this wish has become a reality.

110/330Ω terminal resistance select switch(When battery cover is opeen)

RS-422, RS-485 combined use port

110/330Ω terminal resistance select switch

RS-422, RS-485 combined use port

65

Protective Cover

(depth 80)

90

36

48

22

External Dimensions Speci�cations

Please con�rm with your local MELCO contact about the availability of updated H/W. Refer to the technical news article -0039 for more details.

RS-232 PLC Connection*

USB PC Connection

RS-422 PLC Connection*

RS-485 Multi-drop Connection

GT01-RS4-M *Simultaneous connection impossible

communication drivers can be updated!Using the USB port to connect to

Various communication to connect to all kind of peripheral devices.

Notice To correspond with Multidrop connectivity the GOT hardware has been updated.

Example for the updated hardware of the GT1020 and GT105[ ]

Units : mmExt. color : BlackWeight : 0.3kg

Corresponding S/W version: GT Designer 2 2.93X or later

GT01-RS4-M GT10-9PT5S

Units : mmExt. color : BlackWeight : 40g

Simultaneous Launch of theGT10-9PT5S Connection Adapter

Enables easy wiring to the Multidrop unit forsupported equipment:

GT104[ ], GT105[ ], GT115[ ]

Page 3: FX Customer News Vol 8 - Mitsubishi Electric€¦ · of the FX PLC using cables GT10-C10R4-8P (1m) or GT10-C30R4-8P (3m) Both backlight color options and white frame models are available

Increase Your System Flexibility, Now You Can Connect up to 31 Modbus Devices to One GT10 Series HMI*1

!

NEWS 3

Note: GT Designer2 ver. 2.96A or later is required for connectivity.*1. Refer to the compatibility table for supported products in tech news article -0039*2. Depending on the connected device and communication speed

M o d b u s m a s t e r f u n c t i o n a l i t y i s n o w i n c l u d e d i n G T 10 s e r i e s H M I s

Modbus RTU master functionality is now included in GT10 series HMIs*1. With this, up to 31 compatible Modbus devices such as inverters or temperature controllers can be connected to one GOT.

Maximum cable length: RS-232C=15m*2

RS-485 = 1,200m*2

Maximum communication speed 115.2kbps, depending on the cable length and device

Access to the complete range of devices, according to Modbus speci�cation

ModbusNow Available

1 GOT!Max. 31devices connect to

Max. 1,200m*2

Max. 115.2kbps

Inverter

RS-232C or RS-485

Temp controllerOther Modbus device

NEWS 2

Reduce Setup Time and Cost, Combined Power and Communications Now Available in the GT1030!

NOTE: The DC 5V versions of the GT1030 and GT1020 do not support multi-drop or Modbus master functionality.

T h e N e w G T 10 3 0 D C 5 V P o w e r S u p p l i e d F X S e r i e s P LC

Power and

Communications in 1 cable!

Power and

Communications in 1 cable!

No need for an additional power supply!

Power is supplied through the RS-422 programming port of the FX PLC using cables GT10-C10R4-8P (1m) or GT10-C30R4-8P (3m)

Both backlight color options and white frame models are available

Save time and spend less when installing or con�guring equipment!

The new GT1030 joins the GT1020 with the ability to feed o� of the DC 5V service power supply of the RS-422 communication cable connected to the FX series PLC programming port.

UnitGT1030-LBLGT1030-LWLGT1030-LBLWGT1030-LWLW

Frame ColorBlackWhiteBlackWhite

Backlight

Green/Orange/RedRS-422

White/Pink/Red

PLC Communication

Visualize More Display Options, 16 GOT1000 Series HMIs Can Now Be Joined Together with the Serial Multi-drop Connection Unit!

NEWS 4

Equipped with USB, RS-232, RS-422, RS-485 communication ports enabling 4 channels of communication

Maximum 16 GOT1000 series units

Maximum 500m connection length

16 G O T 10 0 0 S e r i e s H M I s C a n N o w B e J o i n e d To g e t h e r

GOT1000 Series

Serial Multi-drop Connection UnitGT01-RS4-M

Mitsubishi PLCsFX, A, QnA, Q series

GOT hardware versions with Multi-drop support is required

Ever wished to increase your connection distance or expand the number of GOTs in your system? Now this wish has become a reality.

110/330Ω terminal resistance select switch(When battery cover is opeen)

RS-422, RS-485 combined use port

110/330Ω terminal resistance select switch

RS-422, RS-485 combined use port

65

Protective Cover

(depth 80)

90

36

48

22

External Dimensions Speci�cations

Please con�rm with your local MELCO contact about the availability of updated H/W. Refer to the technical news article -0039 for more details.

RS-232 PLC Connection*

USB PC Connection

RS-422 PLC Connection*

RS-485 Multi-drop Connection

GT01-RS4-M *Simultaneous connection impossible

communication drivers can be updated!Using the USB port to connect to

Various communication to connect to all kind of peripheral devices.

Notice To correspond with Multidrop connectivity the GOT hardware has been updated.

Example for the updated hardware of the GT1020 and GT105[ ]

Units : mmExt. color : BlackWeight : 0.3kg

Corresponding S/W version: GT Designer 2 2.93X or later

GT01-RS4-M GT10-9PT5S

Units : mmExt. color : BlackWeight : 40g

Simultaneous Launch of theGT10-9PT5S Connection Adapter

Enables easy wiring to the Multidrop unit forsupported equipment:

GT104[ ], GT105[ ], GT115[ ]

Item SpecificationPLC Connection Interface

Communication Type RS-422, RS-232 standard conformance 1ch (Simultaneous use impossible)Baud rate [bps] 115.200 / 57.600 / 38.400 / 19.200 / 9.600 / 4.800Communication Length RS-422 Connection max 30m, RS-232 Connection max 3mCompatible PLCs MELSEC Series PLCs

Connector Type RS-422 D-sub 9 pin (female), RS-232 D-sub 9 pin (male)GOT Connection Interface

Communication Type Serial RS-485 standard conformance 1ch, internal terminal resistanceTransmission Channel Type Bidirectional half-duplex (1 pair wiring), Bidirectional full-duplex (2 pair wiring) Baud rate [bps] 115.200 / 57.600 / 38.400 / 19.200 / 9.600 / 4.800Communication Length 500m (maximum for entire system)Connection Number Maximum 16 unitsCompatible GOTs Updated GT10 GOTs are connectable. For GT11/GT15/GT16, please contact

your local MELCO contact. Connector Type Terminal Block

PC Connection Interface USB 2.0, Mini-B connectorPower Supply / Supply Voltage DC24V (+10%, -15%)Fuse (internal, replacement unadvisable) 1ACurrent Consumption 3.36W or less (140mA /DC 24V)On-rush Current 14A or less (DC 24.6V, 1mA)General Specification Follows the GOT1000 seriesMounting Method DIN rail or screw mounting

Page 4: FX Customer News Vol 8 - Mitsubishi Electric€¦ · of the FX PLC using cables GT10-C10R4-8P (1m) or GT10-C30R4-8P (3m) Both backlight color options and white frame models are available

NEWS 1 F X 3 G s e r i e s e x p a n s i o n

— Vo l u m e 8 —

NEWS 1 FX3G series expansion.

NEWS 2 The New GT1030 DC5V Power Supplied FX Series PLC.

NEWS 3 Modbus master functionality is now included in GT10 series.

NEWS 4 16 GOT1000 Series HMIs Can Now Be Joined Together.

NEWS 5 New industrial service device for FX PLC, FX-30P.

NEWS 5 N e w I n d u s t r i a l S e r v i c e D e v i c e f o r F X P LC , F X-3 0 P

This unit can perform program uploads/downloads and store up to 15 programs in its internal memory. Keywords can be registered, deleted or canceled in applicable PLCs.

and maintenance tool for all FX Series PLCs. Actual

Size

Compatible with all FX series PLCs.

Max. 21 characters × 8 lines.

Store up to 15 programs

Program monitoring function is available.

The latest firmware can be download.

PLC Program Monitoring,Upload/download

�rmware download

List Monitor Screen

Memory Monitor Screen

USB

USB

The FX3G is an introductory compact PLC and is the newest addition to the FX3 series, designed for simple yet performance-critical applications. Incorporating innovative FX3 series technology the customer is presented with a suite of bene�ts.

FX3G-14MT/ES

FX3G-14MR/ES

FX3G-14MT/ESS

FX3G-24MT/ES

FX3G-24MR/ES

FX3G-24MT/ESS

FX3G-40MT/ES

FX3G-40MR/ES

FX3G-40MT/ESS

Transistor Output Sink

Relay Output

Transistor Output Source

FX3G-60MT/ES

FX3G-60MR/ES

FX3G-60MT/ESS

I/O 14 pointsIn 8 / Out 6

I/O 24 pointsIn 14 / Out 10

I/O 40 pointsIn 24 / Out 16

I/O 60 pointsIn 36 / Out 24

3rd generation compact PLC

Highly �exible

Dual system-bus architecture

Control of up to 128 directly connected I/O points, or up to 256 with CC-Link remote I/O’s.

Product DetailsAll in one CPU, power supply and I/O. Includes many upgraded features from the FX1N. Most notably the usage of the FX3 series ADP bus system and new expansion boards (BD).

Instruction TimesBasic Instructions: 0.21μs / instruction (Contact Instruction)

Memory 32,000 steps of built-in program memory.EEPROM memory cassette with loader functionality is available.

Applicable StandardsAll products support CE and UL/cUL

Large Device MemoryRight side

Complete Lineup of AC Powered FX3G PLCs!

NEW

Auxiliary Relays........7,680 pointsTimers .......................... 320 pointsCounters ..................... 235 points

Data Registers .................... 8,000 pointsExtension registers.......... 24,000 pointsExtension �le registers... 24,000 points

Main Units Lineup

Transistor SourceOutput Type

main unitsare now

available!

The FX-30P is a small, industrial programmingThe FX-30P is a small, industrial programmingand maintenance tool for all FX Series PLCs.

87mm

170m

m

New publication, effective May 2009. Specifications subject to change without notice. Printed in Japan (MEE)

HEAD OFFICE: TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPANHIMEJI WORKS: 840, CHIYODA CHO, HIMEJI, JAPAN