6
walk-away system COMPLETELY AUTOMATIC SYSTEM FOR THE DETERMINATION OF ESR DIRECTLY IN EDTA TUBES. VES CUBE rn INNOVATIVE CLINICAL DIAONOSTIC SYSTEMI

Transcript of Brochure Ves Matic Cube 200

Page 1: Brochure Ves Matic Cube 200

walk-away system

COMPLETELY

AUTOMATIC

SYSTEM FOR THE

DETERMINATION

OF ESR DIRECTLY

IN EDTA TUBES.

VES CUBE rn

I N N O V A T I V E C L I N I C A L D I A O N O S T I C S Y S T E M I

Page 2: Brochure Ves Matic Cube 200

maximum operator protection'

SAFETY& ABSOLUTE AVOIDANCE OF CONTACT WITH BLOOD SAMPLES. THE INSTRUMENT WORKS IN ABSENCE OF WASTE LIQUIDS.

l-.. \ - A -.- 4

"es be-

COMPLETELY

AUTOMATIC

SYSTEM

FOR THE

MINATION

OF ESR

DIRECTLY

IN EDTA

TUBES.

I 1 INSTRUMENT STREAMLINES LABORATORY WORK-FLOW. WALK-AWAY FUNCTION REDUCES TURN-AROUND TIME.

rn I

PRODUCTIVITY

Page 3: Brochure Ves Matic Cube 200

After loading

the samples

and reading

their

identifying

bar codes,

the two-way

connection

of the instrument

and the

complete

host integration

allow the

automatic

selection

of the samples

for which

ESR

testing

is required.

Users can easily

communicate

with the system

through

interactive

software and

a touch screen

which allow

sample

traceability

in every

operating phase:

loading, mixing,

analysis,

classification

and printing

of the results.

I TOUCH [ s c r e e n

Page 4: Brochure Ves Matic Cube 200

The samples selected

for ESR testing are

transferred from

the "Preparer Module"

to the "Analysis

Module" where the

test is executed in four

steps: mixing, first

reading. sedimentation

(20 minutes],

second reading.

To ensure traceability,

each sample is placed

in a specific position

of the Sample

Holder Rack.

ESR results

for each test

are obtained

using standard

ESR test methods

Cthree phases:

rouleaux formation,

sedimentation

and packing].

These results,

obtained in 20 minutes.

correlate with the M I I\I U T F S I westergren citrate

of SEDIMENTATION 1 reference method

la 60 minute test

performed at 1 8" Cl.

Results from

the Ves-Matic Cube 200

follow ICSH

recommendations

CJ Clin Pathol 1 993; 46: 198-2031

Page 5: Brochure Ves Matic Cube 200

TECHNICAL DIMENSIONS

Dimensions in mm [HxWxD]: 6 5 0 x 6 8 0 ~ 6 9 0

Weight: 80 Kg

ELECTRICAL SPECIFICATIONS

Line voltage: US/CAN: 1 10/120 Vac

EUR: 2 3 0 Vac

Frequency: US/CAN: 60 Hz

EUR: 5 0 Hz

Power consumption: 265 VA

ESR Control [4x9 ml) Ref. 10430

ESR Control [2x9 ml] Ref. 10434

C O N S U ~

Check Device Trasponder RF:

10.000 te*

5.000 tests

1 .ooo tests Thermal Roll Paper [ I pcs]

Ref. 10290

Ref. 10291

Ref. 10292

Ref. 1 0403

RU;. NUMBEFIS

Ves-Matic Cube 2 0 0 10370/S

10370/A

10370/BC

- OF THE

7 Continuous loading and random access

7 Test performed directty from cell counter racks

7 Compatible with the most popular brands

of EDTA tubes

7 Up to 190 results/hour

7 Results every 19"

HARDWARE AND S O W A R E

7 Internal and external barcode reader

7 Built-in thermal printer

7 Storage of up to 10.000 data

7 Bdirectional host connection allows for selection

of only the samples for which ESR testing

is required.

7 Two RS232 ser~al ports

7 Two USE host connection ports

7 One USB client connection port

7 One Compact Flash slot

7 Internal Qualrty Control Management

Page 6: Brochure Ves Matic Cube 200

DIESSE Diagnostica Senese SpA Via del Pouo, 5 - Loc. S. Martino 53035 Monteriggioni [SI] Italy Tel. : ++39/0577/3 1.95.60/6 1 /50 Fax: ++39/0577/3 1 .87.63