Module: I Mine Ventilation - Introduction Dr. Nuhindro Priagung Widodo Teknik Pertambangan FakultasTeknik Pertambangan dan Perminyakan, InstitutTeknologi Bandung 2009 NPW 1 Mine Ventilation

Transcript of 01 PPT Mine Ventilation Introduction

  • Module: I Mine Ventilation - Introduction

    Dr. Nuhindro Priagung Widodo

    Teknik Pertambangan

    FakultasTeknik Pertambangan dan Perminyakan, Institut Teknologi Bandung

    2009

    NPW1

    Mine Ventilation

  • Brief History of Mine Ventilation

    NPW2

    Between 4000 and 1200 B.C., European miners dug tunnels into chalk deposits searching for flint.

    The Laurium silver mines of Greece, operating in 600 B.C. have layouts which reveal that the Greek miners were conscious of the need for a connected ventilating circuit.

    The first great textbook on mining was written in Latin by GeorgiusAgricola, a physician in a thriving iron ore mining and smelting community of Bohemia in Central Europe. Agricola's "De Re Metallica", produced in 1556, is profusely illustrated.

    A number of the prints show ventilating methods that include diverting surface winds into the mouths of shafts, wooden centrifugal fans powered by men and horses, bellows for auxiliary ventilation and air doors.

  • NPW3

  • Brief History of Mine Ventilation

    NPW4

    Agricola was also well aware of the dangers of

    blackdamp, air that has suffered from a reduction in

    oxygen content, - 'miners are sometimes killed by the

    pestilential air that they breathe," and of the explosive

    power of "firedamp", a mixture of methane and air

    "likened to the fiery blast of a dragon's breath."

    De Re Metallica was translated into English in 1912 by

    Herbert C. Hoover and his wife, Lou. Hoover was a

    young American mining engineer who graduated from

    Stanford University and subsequently served as President

    of the United States during the term 1929-1933.

  • Brief History of Mine Ventilation

    NPW5

    The Industrial Revolution brought a rapid increase in the demand for coal. Conditions in many coal mines were quite horrific for the men, women, and children who were employed in them during the 18th and 19th centuries. Ventilation was induced either by purely natural effects, stagnating when air temperatures on the surface and underground were near equal, or by fire.

    George Stephenson, admitted to this practice during the inquiries of a government select committee on mine explosions in 1835. A common method of removing methane was to send a "fireman'' in before each shift, covered in sackcloths dowsed in water and carrying a candle on the end of a long rod. It was his task to burn out the methane before the miners went into the working faces.

  • Brief History of Mine Ventilation

    NPW6

    John Buddle (1773-1843), an eminent mining engineer in the north of England produced two significant improvements. First, he introduced "dumb drifts" which bled sufficient fresh air from the base of a downcast shaft to feed the furnace. The return air, laden with methane, bypassed the furnace.

    Buddle's second innovation was "panel (or split) ventilation". Until that time, air flowed sequentially through work areas, one after the other, continually increasing in methane concentration. Buddle originally divided the mine layout into discrete panels, with intervening barrier pillars, to counteract excessive floor heave.

    However, he found that by providing an intake and return separately to each panel the ventilating quantities improved markedly and methane concentrations decreased. He had discovered, almost by accident, the advantages of parallel layouts over series circuits.

    The mathematical proof of this did not come until Atkinson's theoretical analyses several decades later

  • Brief History of Mine Ventilation

    NPW7

    A crisis point was reached in 1812 when a horrific explosion at Felling, Gateshead killed 92 miners. With the help of local clergymen, a society was formed to look into ways of preventing such disasters.

    Contact was made with Sir Humphrey Davy, President of the Royal Society, for assistance in developing a safe lamp. Davy visited John Buddle to learn more of conditions in the mines. As this was well before the days of electricity, he was limited to some form of flame lamp.

    Within a short period of experimentation he found that the flame of burning methane would not readily pass through a closely woven wire mesh. The lamp glowed 'red hot' because of the methane burning vigourously within it, yet the flames could not pass through the wire mesh to ignite the surrounding firedamp.

  • Brief History of Mine Ventilation

    NPW8

    Perhaps the greatest classical paper on mine ventilation was one

    entitled "On the Theory of the Ventilation of Mines", presented by

    John Job Atkinson to the North of England Institute of Mining

    Engineers in December, 1854.

    During Atkinson's productive years the first power driven ventilators

    began to appear. These varied from enormous steam-driven piston

    and cylinder devices to elementary centrifugal fans.

    Improved instrumentation allowed organized ventilation surveys to

    be carried out to measure airflows and pressure drops for the

    purposes of ventilation planning, although there was no practical

    means of predicting airflows in other than simple circuits at that

    time. Atkinson's theory was confirmed in practice. The first

    successful axial fans were introduced in about 1930.

  • Brief History of Mine Ventilation

    NPW9

    In 1943, Professor F.Baden Hinsley produced another

    classical paper advancing understanding of the behaviour of

    airflow by using thermodynamic analyses.

    Hinsley also supervised the work at Nottingham University that

    led to the first practical use of analog computers in 1952 to

    facilitate ventilation planning. This technique was employed

    widely and successfully for over a decade. This is now the

    dominant method used for ventilation planning

  • UNDERGROUND EXCAVATION

    10

  • Longwall Coal Mine

    11 NPW

  • Mining Front

    12 NPW

  • VENTILATION PURPOSES

    13

    Supply a fresh air into the tunnel for inhalation of workers and all of the

    process which happen in the tunnel.

    Mine ventilation means total air conditioning:

    1. Quality control (purifying and removing contaminants)

    a. Gas control vapors and gaseous matter, including radiation

    b. Dust control particulate matter

    2. Quantity control (regulating magnitude and direction of airflow)

    a. Ventilation

    b. Auxiliary or face ventilation

    c. Local exhaust

    3. Temperature humidity control (controlling latent and sensible heat)

    a. cooling; b. heating; c. humidification; d. dehumidification

  • FACTOR AND CONTROL FOR

    MINE VENTILATION RISKS

    14

  • MINE AIR FLOW PRINCIPLES

    15

    Air will flow from the place that have a low temperature to place

    which have a higher temperature (high pressure to low pressure)

    Air will flow through a low resistance ventilation airways rather

    than the higher resistance airways

    Mine ventilation is essentially the application of the principles of

    fluid dynamics to the flow of air in mine openings.

  • AIR PRESSURE

    16

  • THEORY

    17

    (i)

  • MOODY DIAGRAM

    18

  • AIRWAY FRICTION

    19

  • FAN

    NPW20

  • FAN

    NPW21

  • FAN

    22

  • FAN

    23

  • INSTRUMENTS IN VENTILATION SURVEYS

    24

  • TRACER GAS METHODS

    25

  • TRACER GAS METHODS

    26

  • 27 NPW

  • Ventilation Surveys and Simulation

    28 NPW

  • Strata

    Gas

    29 NPW

  • Diesel Exhaust Fumes

    30 NPW

  • Dust

    31 NPW

  • 32 NPW

  • 33 NPW

  • Heat

    34 NPW

  • 35 NPW

  • 36 NPW

  • Workshops and other areas

    37 NPW

  • Air velocity limits

    38 NPW

  • Ventilation Planning

    39 NPW

  • 40 NPW

  • VENTILATION OF ROADWAYS TUNNEL

    41

  • VENTILATION OF ROADWAYS TUNNEL

    42

  • 43

  • SCOPE OF A MINE VENTILATION STUDY

    44

    Review of the various airborne contaminants (dust, gases, radon, heat,

    etc) and how these will be managed.

    Included in this would be filtration, dilution, exhaust or other control

    strategies and any cooling or heating required, and the location, type and

    size of such devices.

    The primary ventilation network at all key milestones in the development,

    construction and production phases.

    This should include the system of airways and their sizes, friction factors

    and shock losses, and the location and specification of all fans and

    ventilation control devices. This is basically addressing the issue of the

    volume and distribution of air throughout the mine life.

  • Scope of a Mine Ventilation

    45

    Secondary/auxiliary ventilation design.

    Review of egress and entrapment provisions in the mine over its life.

    A ventilation management plan which covers the day to day operation

    and management of the ventilation system and any trigger action

    response plans (TARPs), standard work or operating procedures (SWPs,

    SOPs) for ventilation-related tasks, etc.

    Formal risk assessments covering both the normal operations and day-

    to-day activities and all credible abnormal operations or events (power

    failures, fire, collapse of a major airway, etc)

  • KEY FACTORS TO BE CONSIDERED BEFORE COMMENCING

    ANY VENTILATION DESIGN

    46

    Dust, radon and/or methane or other airborne gaseous, fume or particulate

    contaminants or asphyxiants (e.g. nitrogen)

    Gas contents of orebody/coal seam and adjacent strata; issues of gas drainage

    Spontaneous combustion potential

    Outburst potential

    Water inundation (flooding) potential

    Dust audits, silica (or other contaminant) contents of strata

    Production, development, diamond drilling, raiseboring (or other vertical

    development) and production drilling schedules

    Other important schedules or deadlines (e.g. construction schedules)

    Mining methods, layouts, mine design, etc

    Manpower schedule, by job type and location for both production and construction

    phases

  • Key Factors To Be Considered .

    47

    Major mobile equipment schedules, especially diesel equipment (maximum kW rating,

    dimensions, speed loaded and unloaded, up and down ramp, tonnes moved)

    Mode of operation of diesel equipment (where travel,when, truck/loader combinations)

    Diesel fuel usage, average and maximum per shift

    Fixed electrical plant and efficiencies

    Any special areas requiring filtered air or special ventilation (e.g. control rooms, crib

    rooms, offices, ventilation at crusher jaws, transfer points on belts, tipping points)

    Coal, ore, mullock/waste or other materials handling flowcharts

    Humidity limits for ore/waste including transfer points

    Humidity limits for ground control/rock strata

    Backfill system and operation, type of fill, method of placement

    Locations of fuel and oil storage, refueling, other major stores, combustible material, etc

  • Key Factors To Be Considered .

    48

    Parking arrangements

    Special fire fighting standards

    Special egress or entrapment standards

    Any maintenance arrangements impacting on egress (outages, inspections, etc)

    Minimum medical/physical requirements for continuing employment or for visitors

    Blasting arrangements: development and production, bins, chutes, etc, including

    frequency of blasting: development and production

    Re-entry times after blasting etc

    ANFO and other explosives consumption rates: development and production

    Cement usages and consumption rates

    Oxidation rates (to SO2 and/or CO2)

    Working in heat protocols

    Other special ventilation-related hazard protocols

  • Key Factors To Be Considered .

    49

    Internal corporate ventilation/workplace environment standards for each job type (i.e. typical

    ventilation arrangements)

    Statutory (legislative) requirements

    Internal (company or mine) generic standards, hazard management plans, etc

    Any noise criteria (impacting on noise insulation or siting of fans etc)

    Any sources of dust, e.g. due to cutting, loading, etc

    Dust controls (e.g. sprays) at drawpoints, tipples, conveyors, roads

    Other sources of heat

    Surface climate (WB, DB, BP) by hour for minimum of six years

    Surface elevation above sea level

    Depth of mining operations

    Near-surface virgin rock temperature and geothermal gradient

    Rock thermal conductivity, thermal capacity, diffusivity, density

    Maximum heading lengths for auxiliary development, development heights and widths

    Method of auxiliary ventilation, type and size of ducts, leakage factors

  • Key Factors To Be Considered .

    50

    Any existing ventilation circuits, fans (including fan curves), controls etc

    Any existing cooling devices

    Usage and policy on air-conditioned cabins in mobile equipment and fixed plant

    Mining (especially horizontal and vertical development) and ventilation (fan, controls, ducting)

    costs

    Friction (k) factors and shock losses used or measured in the operation

    Any surface considerations (dust from quarrying etc, prevailing winds, grass/bush fires, nearby

    plant)

    Surface environmental limits on fans and shafts: noise, dust, water, smell, visual amenity

    Shaft, raise and other major airway resistances and last time measured

    Standards in regard to allowable pressures on ventilation doors (airlocks) or other ventilation

    controls

    Ventilation or isolation of caved regions or goafs; leakage and pressure balancing

    Network analysis and validation (comparing to measured data)

  • Key Factors To Be Considered .

    51

    Multi-level tipping controls or protocols

    Ground/fissure water in mine (amount, location, temperature (if very hot))

    Location of shafts, fresh and return air raises, distances apart (determines typical auxiliary

    ventilation line configurations and lengths)

    Wetness of shafts. If wet, potential for water corrosion or erosion on fans. Potential for the

    shaft to be subject to erosion or sloughing or water plugging

    Natural ventilation pressures; seasonal changes; impacts of refrigeration on natural ventilation

    pressures

    Network simulation program used; Other computer programs in use or required to be used

    Data on ventilation monitoring (e.g. strata gases, diesel exhausts, airflows, on-line monitoring)

    Recent or relevant ventilation or feasibility studies; Any other safety aspects that need to be

    considered

    Any recent ventilation audits completed; Any concerns from the operators or planners about

    current or future ventilation problems

    Any telemeter, remote monitoring or remote operation/control requirements

  • 52

  • MINE

    VENTILATION

    53

  • COAL UNDERGROUND MINE

    NPW54

  • SERIOUS DISASTERS RELATED TO MINE VENTILATION IN JAPAN

    NPW55

    Date Mine Category Cause Fatalities

    63/11/9 Miike Dust explosion ? 64/6/1 Yamano Gas explosion ? 65/2/22 Yuubari Gas explosion Spontaneous

    combustion

    66/3/22 Sorachi Gas dust explosion Blasting 66/11/1 Honbatsu Gas dust explosion Blasting 68/1/20 Bibai Gas explosion Blasting 68/5/12 Bibai Mine fire ? 68/7/30 Heiwa Mine fire ? 69/4/2 Mojiri Gas explosion Blasting 70/12/15 Sunagawa Gas explosion ? 72/11/2 Ishikari Gas explosion Blasting 73/12/19 Sunagawa Gas explosion ? 75/11/27 Horonai Gas explosion Blasting 77/5/11 Ashibetu Gas explosion Blasting 79/5/16 Minami

    ooyuubari Gas explosion Static electricity

    81/10/16 Yuubari sinkou

    Gas explosion Static electricity

    84/1/18 Ariake Mine fire Belt conveyor 85/4/24 Takashima Gas explosion Static electricity 85/5/17 Minami

    ooyuubari Gas explosion Static electricity

  • 56 NPW

  • 57 NPW

  • 58 NPW

  • 59 NPW

  • 60 NPW

  • NPW61

    Kompas, Senin, 29 November 2004, 02:52 WI

    25 Tewas 140 Terperangkap Dalam Kecelakaan Tambang di Cina

    Tongchuan, Cina, Senin

    Sedikitnya 25 pekerja tambang tewas dan sekitar 140 terperangkap Minggu (28/11) ketika ledakan gas terjadi di sebuah tambang batubara di Cina utara. Kemungkinan ini merupakan musibah terburuk yang melanda produsen tambang terbesar dunia itu dalam beberapa tahun ini.

    Dari 293 petambang yang bekerja di bawah tanah ketika ledakan itu terjadi di tambang batubaraChenjiashan di provinsi Shaanxi, Minggu pagi, 127 berhasil menyelamatkan diri atau diselamatkan, kata timpenyelamat menurut Kantor Berita Xinhua. "Mereka yang menyelamatkan diri dari ledakan gas itu terutamapekerja di dekat pintu terbang dan seluruh korban cedera telah dirawat di rumah sakit, termasuk 11 orangyang cedera parah," kata petugas penyelamat di lokasi kejadian.

    "Seorang pekerja yang diselamatkan mengatakan bahwa meski bekerja di sebuah lokasi sekitar 1.500 meter di bawah tanah, ia terjatuh oleh hempasan arus udara kuat yang ditimbulkan ledakan itu," kata petugastersebut lagi, Senin (29/11) pagi.

    Petugas penyelamat mengalami kesulitan mendekati lokasi ledakan karena tingkat karbon monoksida yang tidak aman. Prioritas utama adalah memperbaiki sistem ventilasi yang rusak parah di tambang itu untukmenjamin keselamatan tim penyelamat, kata Zhao Tiechui, wakil kepala Biro Keamanan Produksi Negara.

    Enam tim penyelamat sedang berusaha menjangkau para pekerja yang terperangkap dan 10 tim tambahandidatangkan untuk membantu mereka. Pemerintah provinsi tersebut telah memerintahkan semua tambangdengan konsentrasi gas tinggi menghentikan operasi mereka untuk pemeriksaan keamanan.

    .

  • AN EXAMPLE OF CONCENTRATIONS OF GASES DOWNWIND OF A FIRE* Saiko to Hoan vol.24,No7,1977

    NPW62

    0

    1

    2

    3

    4

    5

    6

    7

    8

    0 10 20 30 40 50 60 70

    Concentr

    atio

    n(%)

    Time(min)

    H2(%)

    CH4(%)

    CO(%)

    0

    5

    10

    15

    20

    25

    0 10 20 30 40 50 60 70C

    oncentr

    atio

    n(%)

    Time(min)

    O2(%)

    CO2(%)

  • ppm minutes 30min 1-2 hours 8hours

    3000 1600 800 100 2 50000 40000 35000 32000 2 400 150 50 8 2 240 100 50 30 2 1000 700 500 100

    Oxygen (%) Effects on Human Body

    21 None 17 Impaired muscular co-ordination 14 Danger level of self-escape 12 Dizziness, headache, rapid fatigue 9 Unconsiousness 6 Death in 6-8 minutes

    * Birch, N.,Passenger Protection Technology in Aircraft Accident Fires. Gower Technical Press, 1988

    HUMAN TOLERANCE TO TOXIC GASES

    HUMAN TOLERANCE TO OXYGEN DEFICIENCY

    NPW63

  • AIR TEMPERATURE DOWNWIND OF A MINE FIRE

    NPW64

    0

    200

    400

    600

    800

    1000

    50 100 150 200 250 300 350 400

    Tempe

    ratu

    re(

    )

    Distance(m)

    v=3m/s

    v=1m/s

    Temperature (C) 60 70 80 100 120 140 150

    Time (minutes) 120 65 45 15 10 5 1

    HUMAN TOLERANCE TO AMBIENT TEMPERATURE

  • Limits of explosibility, volume (%)

    Combustible gas Lower limit Upper Methane Ethane Propane Carbon monoxide Hydrogen Hydrogen sulfide

    5.0 3.0 2.3

    12.5 4.1 4.3

    15.0 12.5 9.5

    74.2 74.2 46.0

    LOWER AND UPPER EXPLOSIVE LIMIT OF SOME COMBUSTIBLE GASES

    NPW65

  • Methane (CH4)

  • Methane (CH4)

  • MINE FIRE DETECTIONS

  • PERFORMANCE OF MINERS RELATIVE

    TO THE MINE AIR TEMPERATURE

    NPW69

  • OPERATIVE AND EFFECTIVE TEMPERATURE

    Operative temperature Effective temperature

    70 NPW

  • THRESHOLD LIMIT (TIME-WEIGHTED AVERAGE) VALUES FOR VARIOUS DUSTS IN DIFFERENT COUNTRIES (AFTER MAJOR, 1978, AND WALTON, 1978)

    NPW71

    Coal dust (mg/m3) Quartz -containing dust (mg/m3) Asbestos (fibres/ml)

    Australia

    5;respirable dust containing 0.45 mg/m3 6- if quartz

  • Requirements of underground air in quantity and quality< Coal Mine Safety Regulations of Japan >

    NPW72

    (Oxygen and carbon dioxide) Article 86

    Mine air underground where mine workers work or pass shall contain 19% or more oxygen and 1% or less carbon

    dioxide. However, this shall not be applied in cases where oxygen concentration is 19% or more and carbon dioxide

    is 2% or less with permission by the Director-General of MSIB or MSID.

    2. The provision of the preceding Clause shall not be applied the working place where human life rescue or the activity

    regarding safety is conducted in a safe way.

    (Inflammable gas content in the main return air) Article 87

    The inflammable gas content in the main return air shall be kept at 1.5% or less. However, this Article shall not apply to

    cases where inflammable gas from gas drainage holes or exclusive galleries for drainage gas is released into the

    main exhaust, under the condition that the ventilation quantity is sufficient to dilute the inflammable gas

    concentration to 2.5% or less and that permission is given by the Director-General of MSIB or MSID, neither does it

    apply to cases which are stipulated by Article 104-2 and Article 124.

    (Inflammable gas content in working places and roadways) Article 88

    The inflammable gas content shall be kept at 1.5% or less in underground working places and at 2% or less in

    underground roadways. However, this Article shall not be applied to cases stipulated in Item 2 and Item 4 in Article

    124.

    Underground temperature) Article 89

    The temperature of the working place shall be 37 C or less. However, this provision shall not be applied to the working

    place where there is activity due to a special reason such as a gush out of hot spring with permission of the Director-

    General of MSIB or MSID or human life rescue regarding safety is conducted in a safe way.

  • NPW73

    (Ventilation quantity) Article 90

    The ventilation quantity of underground working places shall be decided based on the number of mine workers, the quantity of

    inflammable gas or harmful gas produced, the possibility of spontaneous combustion, temperature and humidity.

    2. Air current and flow volume in underground working place shall maintain adequate speed and volume which is sufficient to dilute

    and sweep away inflammable gas or harmful gas and fumes of blasting.

    Article 91

    In all Class-A pits, the ventilation quantity at the entrance of intake shall be 3 m3 /min per person or more and this is based on the

    maximum number of workers engaging in underground working at the same time. However, when it is required to restrict the

    ventilation quantity for prevention of spontaneous combustion etc. and with the permission of the Director-General of MSIB or

    MSID, the ventilation quantity may be reduced.

    (Ventilation speed) Article 92

    Ventilation speed underground shall be 450 m/min. or less (except an exclusive gallery for ventilation). However, in a shaft the

    speed may increase up to 600 m/min.

    2. The ventilation speed in the preceding Clause may be increased due to a special reason with the permission of the Director-

    General of MSIB or MSID.

    (General ventilation facilities) Article 94

    In a mine having a coal pit where 50 mine workers or more are working, a barometer and a thermometer shall be installed in a

    proper place.

  • Decree of The Minister of Mines and Energy

    No. 555.K/26/M.PE/1995

    on General Mining Occupational Safety and Health

    NPW74

    Part Eight

    Ventilation

    Article 369

    General Provisions

    (1)At any underground mine :

    a. the Technical Mine Manager shall ensure that an adequate supply of fresh air is available at

    every work site with the requirement that the oxygen content in air shall be no less than 19.5

    percent and the carbon dioxide content shall be no more than 0.5 percent;

    b. it is prohibited to send any employee to work at any work site that contains dust smoke or

    vapours in concenhations that may be disruptive to health and

    c. airflow shall be sufficiently adequate to reduce or remove concentrations of smoke from

    blasting as soon as possible.

  • Article 369

    General Provisions

    NPW75

    (2)When the presence of combustible and explosive gases is detected in any mine

    ventilation system, the Technical Mine Manager shall take appropriate corrective

    measures.

    (3)The volume of fresh air passing through the ventilation

    (4) system shall :

    a. be calculated based on the maximum total number of workers at the work location with

    the requirement that no person shall receive less than 2 cubic meters per minute for the

    duration of work and

    b. an additional 3 cubic meters per minute for every degree of horse power where a diesel

    machine is being operated.

    (5)The Mine Inspector may order the Technical Mine Manager to increase the quality and

    volume of fresh air flow at any section of the mine.

    (6) It is prohibited to re-circulate air in any ventilation system.

  • Article 370

    Ventilation Standards

    NPW76

    (1)The air temperature in any underground mine shall be maintained at between 18 degrees

    Celsius and 24 degrees Celsius with maximum relative humidity at 85 percent.

    (2)Apart from the requirements of paragraph (1) letter a the ventilation conditions at the work

    site shall :

    a. for an average of 8 hours :

    1) have a carbon monoxide (CO) volume of no more than 0.005 percent;

    2) have a methane (CH4) volume of no more than 0.25 percent;

    3) have a hydrogen sulphide (H2S) volume of no more than 0.001 percent and ,

    4) have a nitrous oxide (NO) volume of no more than 0.0003 percent.

    b. over any 15 minute period :

    1) CO must not exceed 0.04 percent and

    2) NO2 must not exceed 0.0005 percent.

    (3)Flame safety lamps or any other suitable device shall be used to test for any lack of oxygen.

    (4)Any location that does not require ventilation shall be sealed and signs prohibiting entry

    thereto shall be installed.

  • Article 370

    Ventilation Standards

    NPW77

    (5) In every sealed area, stoppings shall be provided with a pipe and a valve to permit sampling of

    the atmosphere and measurement of the pressure behind such seal.

    (6)The ventilation velocity shall be no less than 7 meters per minute and shall be increased in

    accordance with work requirements and after blasting.

    (7)All airways shall be of adequate dimensions for the quantity of air they are designed to pass.

    (8)The Technical Mine Manager shall appoint an employee who shall be in charge of supervising

    ventilation of the mine and the name of the said employee shall be recorded in the Mine Book.

    (9)The quantity and quality of air being distributed to every work area shall be determined at

    intervals of at least once per month

    (10) The locations at which measurements are taken shall include:

    a. every main intake airway, as near as practicable to the entrance of the shaft or outlet;

    b. at every split where air leaves the main airfIow, as near as possible to the junction;

    c. where the split serves a working district : 50 meters from the first working place at which the air enters, and 50

    meters from last working place at which the air leaves the district;

    d. in the district return airway, as near as practicable to the junction with the main return airway.

    e. any other place stipulated by the Mine inspector.

  • Article 370

    Ventilation Standards

    NPW78

    (11) Sampling to determine & oxygen content (O2), carbon dioxide content (CO2),

    carbon monoxide content (CO) and nitrous oxide content (NO2) of the air taken under

    normal working conditions shall be implemented at intervals of at least once per month at the

    following places:

    a. 30 meters from the working face of development headings;

    b. 15 meters from the winzes and shafts and

    c. at the base of the up-cast shaft and at any stope with only one access way.

    (12) Sampling for the purpose of determining the carbon monoxide content (CO) and

    nitrous oxide (NO2) content at any location or at the end of any shaft where a diesel machine

    is being operated shall be carried out at intervals of at least every seven days.

    (13) Results of findings of the requirements of paragraph (11) and paragraph (12) shall

    include the time and location of where the samples were taken as well as the time of the most

    recent blasting.

    (14) Temperature shall be measured regularly at locations as required in paragraph (10)

    letter c and d, and where the temperature exceeds 24 degree Celcius, the said place shall be

    inspected every week.

  • Article 370

    Ventilation Standards

    NPW79

    (15) Measuring for dust concentrations at lower than l0 microns shall be carried out

    as often as practicable but no less than once every three months except where otherwise

    stipulated by the Chief Mine Inspector.

    (16) When any changes are made to the direction or distribution of airflow which

    affects the amount of air entering or leaving and area, air measurements shall be carried

    out as soon as possible after the said change is made.

    (17) The results of air measurements as required in paragraph (16) shall be recorded

    in the ventilation book.

    (18) Ventilation measuring shall be carried out by a competent person.

    (19) Sampling as specified in paragraph (1) and (2) shall not be required where

    according to the judgment of the Chief Mine Inspector the condition of ventilation in the

    mine is adequate.

  • Article 371

    Natural Ventilation

    NPW80

    (1)Use of natural ventilation shall be approved by the Chief Mine Inspector.

    (2)When every part of the mine continuously makes use of natural ventilation the

    requirements of Article 369 and Article 370 shall be fitted with a ventilation fan at the

    surface which shall be used when required.

    (3)Based on the size of the mine and the condition of the environment of work sites at the

    mine the Mine Inspector may require that an auxiliary ventilation fan is necessary with a

    capacity of no less than what is required to distribute an adequate quantity of air which is

    required to workers when evacuation must be carried out.

  • Article 372

    Ventilation Fans

    NPW81

    (1)Whenever practicable, surface ventilating fans (main fans) shall be equipped with the

    following:

    a. an alternative power source;

    b. a water gauge;

    c. either an automatic fan rotation indicator or an automatic air pressure indicator;

    d. an efficient air lock;

    e. a fan drive and fan house both of which must be fireproof;

    f. fireproof air ducts and pressure relief devices;

    g. equipment that is capable of reversing the direction of the flow of air and on which regular testing must be

    carried out and

    h. other safety devices which shall be stipulated by the Chief Mine Inspector.

    (2)The Technical Mine Manager shall provide instructions to the operator of the ventilation

    fan about the rotation speed of the said fan.

    (3)The operator as required in paragraph (2), shall test the ventilation fan, and observe the

    water gauge and the automatic indicators at intervals of at least every 2 hours.

  • Article 372

    Ventilation Fans

    NPW82

    (4)When the measuring devices and the automatic ventilation pressure recorder are not available,

    the operator of the ventilation fan shall record the rotation speed of the wind fan and the

    pressure as indicated on the water gauge every two hours.

    (5)As required in paragraph (2), the operator shall make a report to his/her supervisor of the

    following :

    a. any damage, deviations or the stopping of the ventilation fan and

    b. unusual variations in pressure as indicated by the water gauge.

    (6)Every ventilation fan at the surface of a mine that is not attended shall be fitted with

    permanent monitoring equipment which sends early warnings of the presence of any defects

    in the operation of the ventilation fan to a location that is always manned.

    (7)The intake (suction site) of fans shall be provided with an adequate guard or screen.

    (8)Depending on the size and the environmental conditions of the mine, the Mine Inspector may

    determine the need for a reserve ventilating fan available for immediate use and capable of

    producing sufficient airflow.

  • Article 372

    Ventilation Fans

    NPW83

    (9) The ventilation fan housing, the air duct connections, the fan house, and other buildings in the vicinity of the ventilation fan shall be constructed of non combustible materials, However, where made from combustible materials the wind fan and surrounding buildings shall be adequately protected from fire.

    (10) The up-cast shaft connected to a drift or air duct to the ventilation fan shall be fitted with an airlock which prevents the occurrence of short circuits of airflow.

    (11) It is prohibited to build any combustible structure within a distance of 50 meters of the ventilation fan house.

    (12) The auxiliary ventilation fan shall be installed underground while other ventilation fans may also be installed after approval is obtained" to ensure that disruptions to the safety and health of underground mine workers will not occur.

    (13) All underground main fans shall have controls placed at a suitable protected location remote from the fan preferably on the surface. An independent alternative power supply from the surface shall be provided.

    (14) It is prohibited to stop a ventilation fan except where approval has been obtained from the ventilation supervisor.

  • Article 372

    Ventilation Fans

    NPW84

    (15) It is prohibited to install an booster fan underground except where a ventilation survey has

    been conducted.

    (16) All ventilating fans installed and used to ventilate active workings of the mine, shall be

    operated continuously while persons are underground in the active areas except for scheduled

    production cycle shutdowns or planned fan maintenance or adjustment. All persons

    underground in the affected areas shall be advised in advance of such scheduled fan shutdowns.

    No blasting operations shall be allowed during any fan stoppage.

    (17) In the event of a fan failure due to malfunction, accident, power failure or any other such

    unplanned or unscheduled events, all mine workers shall leave any area ventilated by the fan

    except any employee who is repairing the said ventilation fan.

    Ventilation shall be maintained and restored to normal before any mine worker enters any

    area affected by the ventilation system.

    (18) All ventilation fans shall be maintained in accordance with the manufacturer's instructions or

    the written schedule as specified by the Technical Mine Manager.

  • Article 373

    Ventilation Fan Systems

    NPW85

    (1) Before any auxiliary fan is installed below ground the Underground Mine Manager must be satisfied that a sufficient quantity of air is reaching the fan to prevent recirculation of air, and this air is not polluted by dust, smoke, or hazardous gases.

    (2) Auxiliary ventilation fans shall be equipped with grounding devices.

    (3) Auxiliary ventilation fans may only be activated, operated and turned off by the authorized employee.

    (4) Auxiliary fans shall be installed at a point at least 5 meters from the nearer side of the entrance to the place to be ventilated by it.

    (5) When two or more auxiliary fans are installed in a series the requirements of paragraph (4) shall only apply to one of the said fans.

    (6) Any forcing type auxiliary ventilation fans shall be installed at the intake airway and exhaust type auxiliary ventilation fans shall be installed at the return airway.

    (7) There shall be installed and maintained with every auxiliary fan an air duct to within a distance from the working face of 5 times the square root of the roadway cross-section, measured in meters.

  • Article 373

    Ventilation Fan Systems

    NPW86

    (8) When an auxiliary fan fails to function all workers shall be prohibited from entering any

    place ventilated by the fan until the said place is declared safe following an inspection by

    the operational supervisor.

    (9) Compressed air may not be used solely for ventilation except in narrow and steep raises.

    (10) Air for ventilation in raises shall be provided such that the flow can be controlled from

    a valve at the foot of the raise. Development raises shall be provided with two air valves,

    one at the foot of the raise and one at the end of the steel pipe inside.

    (11) Ventilation pipes for raises must be independent of service pipes and fitted at the outlet

    with a diffuser.

    (12) Where compressed air is used for ventilation the air shall be sampled at monthly

    intervals to determine CO, NO2 and oil mist content No air shall be used if the analysis

    exceeds the limits specified in paragraph 2 of Article 370.

  • Article 374

    Ventilation Circuits

    NPW87

    (1)The main intake airway and the main return airway shall be made in separate shafts or

    adits.

    (2)The Chief Mine Inspector may grant exemption of the requirements in Paragraph (1).

    (3)Ventilation in the shaft may only be made with the following provisions :

    a. vent tubing may be used at the same opening at the time of development of the shaft or slope and

    b. the intake airway and return airway at the single shafts shall be provided with air curtains.

    (4)Fresh air that enters through the downcast shaft shall be properly distributed to all work

    places as required.

    (5)Where any abnormality occurs to the ventilation circuit or any abnormal change occurs

    in the flow of air, the underground mine workers shall inform the operations supervisor.

    (6)All airways shall be kept clear to permit free passage of air.

  • Article 375

    Prevention of Air Leakage

    NPW88

    (1)Any shaft or outlet to the surface that is corrected via a drift to ventilation fans at the surface and

    which are normally used for hoisting or transportation shall be fitted with efficient air locks and be

    well maintained.

    (2)Every drift which connects main intake airways to the main return airway or which connects the

    intake and return airways shall be fitted with two adequate doors and shall be well maintained to

    reduce leakage of air to a minimum. Where this is not possible other means must be used.

    (3)Any drift which requires prevention from short circuiting of air flow shall be fitted with no less than

    two adequate doors and be well maintained. Where this is not possible one door is allowable with

    one or two ventilation curtains.

    (4)A space shall be provided between the ventilation door or ventilation curtain in order that when one

    door or ventilation curtain is opened the other door or ventilation curtains closed to prevent air

    from passing.

    (5)Ventilation doors shall be capable of closing automatically and ventilation curtains must be

    fireproof.

  • Article 375

    Prevention of Air Leakage

    NPW89

    (6) It is prohibited to prop a ventilation door open except where and for so long as it is

    necessary to allow a vehicle to pass through it. Any door no longer required to be shut

    shall be removed and placed in a position in which it will not obstruct the airflow.

    (7)Every person shall properly close any door or ventilation curtain through which he/she

    passes.

    (8)Only authorized employees shall change ventilation regulators.

  • Article 376

    Ventilation Plans

    NPW90

    Apart from the requirements of Article 19, the ventilation plan shall include the following information :

    a. the name of the mine and

    b. the most up-to-date map or series of maps with the scale no larger than I : 5000, and which includes :1) the direction and distribution of airflow:

    2) the location of the main ventilation fan, the booster ventilation faq and auxiliary fans;

    3) the location ofthe air regulator doors, stoppings, and ventilation doors:

    4) the location of undercasts or overcasts, and other crossings;

    5) the location of seals at abandoned work site areas;

    6) the location ofareas not ventilated;

    7) the location of workshops, fuel storage areas, the hoist room, compressors, battery charging rooms, and explosive magazines and

    8) air measuring stations and the latest ventilation measurements taken.

    c. data on the main fan, the booster fan and auxiliary fans including the name of the manufacturer, the type, the size of the fan, the speed of the fan, the size of the blades, pressure at several points and motor brake horsepower rating;

    d. the number and type of vehicles using fuels underground including the horsepower of the said machines and

    e. any other information requested by the Chief Mine Inspector.