VISUCAM 500 - Florianópolis...info@zeiss.co.in Italy Carl Zeiss S.p.A. Viale delle Industrie 20...

Post on 08-Oct-2020

6 views 0 download

Transcript of VISUCAM 500 - Florianópolis...info@zeiss.co.in Italy Carl Zeiss S.p.A. Viale delle Industrie 20...

VISUCAM 500Have it all

Stereo Indocyanine Green Angiography

(ICGA)

Color Fluorescein Angiography (FA) Macular pigment optical density (MPOD)

assessment

ZEISS AutoMapAnterior segment imagingFundus Autofluorescence (FAF)

VISUCAM 500As versatile as eye diseases

Superior patient comfort, more efficient workflow and improved eye care – a complete system like the VISUCAM® 500 from ZEISS offers many advantages. Highly versatile, VISUCAM 500 is ideal for efficiently diagnosing and monitoring a broad range of typical eye diseases such as AMD, glaucoma and diabetic retinopathy.

VISUCAM 500 combines advanced features such as fundus autofluorescence, easy stereo image management and innovative assessment of macular pigment optical density with intelligent auto functions, enabling intuitive imaging with reproducible results for every patient eye. That is the versatility of VISUCAM 500.

2 3

Live visualization

Captured images are immediately displayed on

the monitor for fast assessment. All processing

functions are only a double click away. Workflow

support tools include:

• Variousmagnifyingfeatures

• Simplifiedsearchforimagesandpatients

• Drag&dropfunctionalityforprintoutpreparation

Step-by-step support

From easy capture and viewing to comprehensive

patienteducation,VISUCAM500provides

high-quality images in a natural, intuitive and

continuous workflow sequence.

Smart adjustment aids

If desired, intelligent auto functions support fast

and easy capture of fundus images.

• Pupilcheck

• Smallpupilmode(≥3.3mm)

• AutoFocus

• AutoFlash

• Easypositioningwithworkingdistancedots

Easy monitoring of AMD patients

Age-related macular degeneration (AMD) is a major reason for vision loss.

The fundus autofluorescence option is an important noninvasive diagnostic

tool to provide improved visualizations for quick and easy monitoring of

dry AMD progression, including geographic atrophy. The autofluorescence

technique used in the ZEISS fundus camera is a single-shot technique that

works in the blue-green spectral range to minimize strain to the patient.

The autofluorescence is an optional module. It is possible to conveniently

upgrade the VISUCAM 500 at any time – without additional hardware.

More information by 3D view

Withthestereomode,3Dimagesareeasyto

captureandmanage.Savedinasinglefile,the

VISUCAM500softwarerememberseverychange

of the JPS image pair. With its excellent image

quality,7-fieldmodeandstereoimages,

VISUCAM500isaperfectfitforclinicalstudies.

Automatic multi-image montage

Whether for details or an overview of the

retina – the ZEISS AutoMap provides both.

Manual and automatic positioning as well

asinternalfixationtargetoptionshelpto

manage panorama imaging.

Simply more imaging

As a highly comprehensive screening and monitoring instrument with numerous onboard image capture and visualization functions, VISUCAM® 500 provides a lot of different views.

Convenient MPOD assessments

The innovative MPOD image analysis software

enables convenient assessments of the macular

pigment optical density with reproducible results

and3Dvisualization.

Imaging made easy

VISUCAM 500 features a variety of smart auto functions and workflow-driven user interface combining capture process and image review at one flat screen. It makes imaging very easy, even for untrained users.

4

Technical dataVISUCAM 500

Fundus camera system

Field angle 45° and 30°

Capture modes Color, red-free, blue and red images, and images of the anterior segment, as well as fluorescein angiography; optional: fundus autofluorescence, ICG angiography, stereo, MPOD

Filters Optical filter: FA + ICGA: exciter and barrier filters, filters for green and blue images, filters for fundus autofluorescence and MPOD, UV / IR barrier filter

Compensation for ametropia +35 D ... –35 D, continuous

Capture sequence From 1.5 seconds (depends on flash energy)

Pupil diameter ≥ 4.0 mm, ≥ 3.3 mm (30° small pupil mode)

Working distance 40 mm (patient’s eye – front lens)

Capture sensor CCD 5.0 megapixels

Monitor 19“ TFT (1280 x 1024) connected via isolating transformer; optional 24” TFT (1920 x 1200)

Fixation targets External and internal; attention mode for internal fixation target (magnified and blinking cross); various programmed sequences or freely positionable

Flash energy Xenon flash lamp, 24 flash levels (max. 80 Ws)

Database Patient information and images with field angle, FA time, R/L recognition and date of visit

Computer

Operating system Windows Embedded

Hard drive Storage of over 150,000 images possible (present size: 320 GB)

Interfaces USB ports and network connectors, DVI port

Export/import Image formats: DICOM OP, DICOM VL, BMP, TIFF, JPEG; Patient list, DICOM MWL, DICOM storage

Internal DVD burner UDF format (DVD, CD)

Instrument table Asymmetric, suitable for wheelchair

Accessories USB printer, USB memory, sliding keyboard shelf, network isolator FORUM eye care data management system, VISUPAC archiving and review system

Dimensions

Basic device 410 mm x 480 mm x 650 mm (headrest) (W 16.14 x D 18.90 x H 25.59 inches)

Monitor 405 x 65 x 335 mm (W 15.95 x D 2.56 x H 13.19 inches) (depends on model)

Weight (basic device) 30 kg (66.1 lbs)

Rated voltage 100 … 240 V ±10% (self-adjusting)

Frequency 50/60 Hz

Power consumption 400 VA

Image courtesy of:

StephanDunkerMD,OphthalmicPracticeEngelskirchenundDunkerGermany(p.2,3,4,5)

RolandSchmidt,UniversityHospitalGiessen-Marburg,Germany(p.2,3)

MatthiasJütteMD,OphthalmicPracticeJütte,Jurkutat,Ilgner,Germany(p.2,3,4,5)

ThomasBehlingMD,OphthalmicPracticeBehling,Lück,Morche,Tschiersch,Germany(p.2,3)

CliffWilliamsFBDO,DispensingOptician&IndependentPracticeOwner,UK(p.2,3,4,5)

All relevant data at the user’s fingertips

VISUCAM® 500 can significantly improve practice workflow efficiency, allowing users to fully concentrate on what matters most: delivering optimal patient care.

Konturdicke 8ptKonturfarbe 60% kFüllung 10% k

Back office

Exam lane 1 Exam lane 2

Fundus photography

Biometry OCT Visual Field

Instrument(non-DICOM)

Instrument(no network)

FORUM LINK net

FORUM Viewer

for instruments without DICOM resp.without network interface

FORUM Archive

net port

net

FORUM LINK port

Electronic Medical Record

port

Practice reception area

Compact eye care workstation

VISUCAM 500 is a package deal, incorporating all capture modes needed for routine procedures

as well as a computer and database for fast image transfer.

Safe, consistent data storage

With its multiple archiving options, VISUCAM 500 provides heightened data security through

easy Network Archive Storage (NAS), hard disk or DVD. When combined with FORUM,

VISUCAM 500 data is automatically backed up and archived.

Images wherever you need them

Connecting the VISUCAM 500 to the FORUM data management solution from ZEISS

enables quick and convenient viewing and comparing of diagnostic data in your practice

or from remote sites. With the modality worklist, patient demographic information can be

conveniently transferred from FORUM to the VISUCAM 500 without retyping, thus saving

time and reducing charting errors.

6 8 96

All relevant data at the user’s fingertips

VISUCAM® 500 can significantly improve practice workflow efficiency, allowing users to fully concentrate on what matters most: delivering optimal patient care.

Konturdicke 8ptKonturfarbe 60% kFüllung 10% k

Back office

Exam lane 1 Exam lane 2

Fundus photography

Biometry OCT Visual Field

Instrument(non-DICOM)

Instrument(no network)

FORUM LINK net

FORUM Viewer

for instruments without DICOM resp.without network interface

FORUM Archive

net port

net

FORUM LINK port

Electronic Medical Record

port

Practice reception area

Compact eye care workstation

VISUCAM 500 is a package deal, incorporating all capture modes needed for routine procedures

as well as a computer and database for fast image transfer.

Safe, consistent data storage

With its multiple archiving options, VISUCAM 500 provides heightened data security through

easy Network Archive Storage (NAS), hard disk or DVD. When combined with FORUM,

VISUCAM 500 data is automatically backed up and archived.

Images wherever you need them

Connecting the VISUCAM 500 to the FORUM data management solution from ZEISS

enables quick and convenient viewing and comparing of diagnostic data in your practice

or from remote sites. With the modality worklist, patient demographic information can be

conveniently transferred from FORUM to the VISUCAM 500 without retyping, thus saving

time and reducing charting errors.

6

The moment innovation and passion lead to the best vision for your patient. This is the moment we work for.

// OPHtHAlMIC SOlutIOnS MADE By CARl ZEISS

6

Publ

icat

ion

No:

000

000-

2022

-956

Pr

inte

d in

Ger

man

y CZ

-VIII

/201

2 In

tern

atio

nal V

ersi

on: N

ot fo

r sal

e in

the

Uni

ted

Stat

es.

The

cont

ents

of t

he b

roch

ure

may

diff

er fr

om th

e cu

rrent

sta

tus

of a

ppro

val o

f the

pro

duct

in y

our c

ount

ry. P

leas

e co

ntac

t our

regi

onal

repr

esen

tativ

e fo

r mor

e in

form

atio

n. S

ubje

ct to

cha

nge

in

des

ign

and

scop

e of

del

iver

y an

d as

a re

sult

of o

ngoi

ng te

chni

cal d

evel

opm

ent.

VISU

CAM

is a

regi

ster

ed tr

adem

ark

of C

arl Z

eiss

Med

itec

AG. P

rinte

d on

ele

men

tal c

hlor

ine-

free

blea

ched

pap

er.

© 2

012

by C

arl Z

eiss

Med

itec

AG. A

ll co

pyrig

hts

rese

rved

.

Carl Zeiss Meditec AG Goeschwitzer Strasse 51–5207745 JenaGermanywww.meditec.zeiss.com/visucam500

0297

Your local contact:

ArgentinaCarl Zeiss Argentina S.A.Calle Nahuel Huapi 4015 / 25C1430 BCO Buenos AiresArgentinaPhone: +54 11 45 45 66 61bruzzi@zeiss.com.ar

AustraliaCarl Zeiss Pty Ltd Tenancy Office 4, Level 1 40-52 Talavera Road North Ryde NSW 2113 AustraliaPhone: +61 2 9020 1333med@zeiss.com

AustriaCarl Zeiss GmbHLaxenburger Str. 21100 ViennaAustriaPhone: +43 1 79 51 80austria@zeiss.org

BelgiumCarl Zeiss NV-SAIkaroslaan 491930 ZaventemBelgiumPhone: +32 2 719 39 11info@zeiss.be

BrazilCarl Zeiss do Brasil Ltda.Av. Naçoes Unidas, 21711CEP04795-100 São PauloBrazilPhone: +55 11 5693 5521medbrasil@zeiss.org

CanadaCarl Zeiss Canada Ltd.45 Valleybrook DriveToronto, ON M3B 2S6CanadaPhone: +1 800 387 8037czcmed@zeiss.com

ChinaCarl Zeiss Shanghai Co. Ltd.1/f., Ke Yuan Building11 Ri Yin Nan RoadWaigaoqiao Free Trade Zone2005 Yang Gao Bei RoadShanghai 200131ChinaPhone: +86 21 5048 17 17sro@zeiss.com.cn

Czech RepublicCarl Zeiss spol. s.r.o.Radlická 14/3201150 00 Prague 5Czech RepublicPhone: +420 233 101 221zeiss@zeiss.cz

FranceCarl Zeiss Meditec France SAS60, route de Sartrouville78230 Le PecqFrancePhone: +33 1 34 80 21 00med@zeiss.fr

GermanyCarl Zeiss Meditec VG mbHCarl-Zeiss-Strasse 2273447 OberkochenGermanyPhone: +49 7364 20 6000vertrieb@meditec.zeiss.comSurgical Ophthalmology:Phone: +49 800 470 50 30iol.order@meditec.zeiss.com

Hong KongCarl Zeiss Far East Co. Ltd.Units 11-12. 25/FTower 2, Ever Gain PlazaNo. 88 Container Port RoadKwai ChungHong KongPhone: +852 2332 0402czfe@zeiss.com.hk

IndiaCarl Zeiss India Pvt. Ltd.Plot No.3, Jigani Link RoadBommasandra Industrial Area Bangalore - 560 099IndiaPhone: +91 80 4343 8000info@zeiss.co.in

ItalyCarl Zeiss S.p.A.Viale delle Industrie 2020020 Arese (Milan)ItalyPhone: +39 02 93773 1infomed@zeiss.it

JapanCarl Zeiss Meditec Japan Co. Ltd.Shinjuku KuTokyo 160-000322 Honchio-ChoJapanOphthalmic instruments:Phone: +81 3 33 55 0331medsales@zeiss.co.jpSurgical instruments:Phone: +81 3 33 55 0341cmskoho@zeiss.co.jp

MalaysiaCarl Zeiss Sdn Bhd.Lot2, Jalan 243/51 A46100 Petaling JayaSelangor Darul EhsanMalaysiaPhone: +60 3 7877 50 58malaysia@zeiss.com.sg

MexicoCarl Zeiss de México S.A. de C.V.Avenida Miguel Angel de Quevedo 49604010 Mexico CityMexicoPhone: +52 55 59 99 0200cz-mexico@zeiss.org

NetherlandsCarl Zeiss B.V.Trapezium 300Postbus 3103364 DL SliedrechtNetherlandsPhone: +31 184 43 34 00info@zeiss.nl

New ZealandCarl Zeiss (N.Z.) Ltd.15B Paramount DriveP.O. Box 121 - 1001Henderson, Auckland 0650New ZealandPhone: +64 9 838 5626med@zeiss.com

PolandCarl Zeiss sp. Z o.o.ul. Lopuszanska 3202-220 WarsawPolandPhone: +48 22 858 2343medycyna@zeiss.pl

SingaporeCarl Zeiss Ptd. Ltd.50 Kaki Bukit PlaceSingapore 415926SingaporePhone: +65 6741 9600info@zeiss.com.sg

South AfricaCarl Zeiss (Pty.) Ltd.363 Oak AvenueFerndaleRandburg 2194South AfricaPhone: +27 11 886 9510info@zeiss.co.za

South KoreaCarl Zeiss Co. Ltd.Seoul 121-828Mapo-gu141-1, Sangsu-dong2F, BR Elitel Bldg.South KoreaPhone: +82 2 3140 2600korea@zeiss.co.kr

SpainCarl Zeiss Meditec Iberia S.A.U.Ronda de Poniente, 15Tres Cantos28760 MadridSpainPhone: +34 91 203 37 00info@zeiss.es

SwedenCarl Zeiss ABTegeluddsvaegen 7610254 StockholmSwedenPhone: +46 84 59 25 00info@zeiss.se

SwitzerlandCarl Zeiss AGFeldbachstrasse 818714 FeldbachSwitzerlandPhone: +41 55 254 7534info@zeiss.ch

ThailandCarl Zeiss Thailand90 CyberWorld Tower A, 36th Floor, Unit A 3601230 Ratchadapisek RoadHuaykhwang, Bangkok 10310ThailandPhone: +66 2 248 8787thailand@zeiss.com.sg

United KingdomCarl Zeiss Ltd. 509 Coldhams lane Cambridge CAMBS CB1 3JS, United KingdomPhone: +44 1707 871200info@zeiss.co.uk

United States of AmericaCarl Zeiss Meditec, Inc.5160 Hacienda DriveDublin, CA 94568USAPhone: +1 925 557 4100info@meditec.zeiss.com