Our Commitment to the Mining IndustrySince the electrification of mines, Nexans AmerCable’s core business has been providing innovative cable solutions for mining applications.Open cut or underground – no matter where or what you’re mining – Nexans AmerCable has a cable productivity solution for you. Our innovatively engineered and manufactured cables are designed for the toughest conditions. As the leading global supplier of mining cables, Nexans AmerCable is dedicated to producing:
■ cables that last longer in harsh Australianmining conditions
■ cables designed to help provide greater levels of safety and productivity
■ innovative solutions to cable issues
Mining Cable Innovation■ New product development that addresses
environmental, safety and cost reduction issues specific to your mining application
■ Designing insulating and sheathing materials that are highly flexible and have greater resistance to abrasion and moisture
■ Cable constructions that last longer providing reduced down time for increased production
Operating Excellence■ On-Time delivery
■ Nexans AmerCable is an ISO-9001 certified manufacturer
Hands-on Field Support
Our experienced Australianapplication engineers are
available for on-site evaluationand productivity solutions.
Education and training sessionscan be conducted to addressbest cable handling practices
for maximum service life.
PbAll materials in
Nexans AmerCableAustralia’s mining
cables are lead free.
1
Nexans AmerCable believes the information presented throughout this catalog to be reliable and current. All information is subject to change without notice. The information listed is approximate, and is presented only as a guide for product selection. We make no claims or warranties for the suitability of any product for any particular application.
© 2013, AmerCable Incorporated
Table of Contents
Type 241 1.1 - 11kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 4
Type 245 1.1 - 3.3kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
Type 275 1.1kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8
Type 441 1.1kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Type 441 6.6kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Type 441 11kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Type 441 22kV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Type 441 Enhanced (SCR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-14
Type 450 (SCR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-16
Mine Safe Feeder Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Engineering & Technical Support . . . . . . . . . . . . . . . . . . . . . . 18
Safety in Colours . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Sheaths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Mechanical Information . . . . . . . . . . . . . . . . . . . . . . . . . 21 - 22
Electrical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 - 25
Manufacturing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . Back Cover
2
The Innovative Cable Solutions Company
Type 241Mould-cured CPE Sheath • 1.1kV
SummaryGeneral use cable suitable for undergroundmining. Used for continuous miners, longwallsystems, feeder cable to pumps and generalpower supply (excluding shuttle cars).
Nexans AmerCable Mining Cable meets orexceeds AS/NZS 1802 Standards.
Photo courtesy Joy
SheathReinforced mould-cured heavy duty thermosetting elastomer sheath HD-90-CPE
Cable identification via permanent marking
Conductors (3)Flexible tinned copper
Central Pilot CoreEPR coveredextensible tinned copper
Insulation ScreenSemiconductive elastomer
Earth Conductors (3)Semiconductiveelastomer covered flexible tinned copper
Separator Tape1.1/1.1kV – polyester3.3/3.3kV andabove usessemiconductivescreen
Core Assembly ScreenSemiconductive elastomer
InsulationEthylene-propylene rubber (EPR) R-EP-90
Cradle SeparatorSemiconductiveelastomer
NominalArea(mm2)
NominalStrandSize
(#/mm)
NominalDiameter
Over Insulation(mm)
InsulationThickness(mm)
Semi-ConductiveCoveringThickness(mm)
NominalStrandSize
(min#/mm)
SheathThicknessIncludingSemi-
ConductiveCore Screen
(mm)
NominalOverallDiameter(mm)
Approx.Mass
(kg/100m)
Power Conductor Earth Conductor
Part No.35-000-006 6 84/0.30 1.5 8.5 21/0.25 1.0 3.8 29.8 111010 10 133/0.32 1.5 9.7 42/0.25 1.0 3.8 32.5 137016 16 133/0.40 1.6 11.3 69/0.25 1.0 3.9 36.1 179025 25 209/0.40 1.6 12.6 91/0.25 1.0 4.2 39.6 233035 35 285/0.40 1.6 13.6 140/0.25 1.0 4.4 41.9 280050 50 399/0.40 1.7 15.5 161/0.25 1.0 4.9 47.1 357070 70 342/0.51 1.8 17.5 69/0.51 1.0 5.3 52.3 480095 95 456/0.51 2.0 19.8 69/0.51 1.0 5.8 58.3 600120 120 627/0.51 2.1 22.4 69/0.51 1.2 6.3 66.0 762150 150 777/0.51 2.3 25.3 91/0.51 1.2 6.7 71.9 935185 185 925/0.51 2.5 27.3 112/0.51 1.4 7.3 77.5 1085240 240 1221/0.51 2.8 30.2 133/0.51 1.4 8.0 85.2 1363300 300 1480/0.51 3.0 33.8 175/0.51 1.4 8.7 94.2 1645
Type 241.1 (1.1/1.1kV)
3
Standard cable sheath is black.
See pages 19-20 for other available
colours and striping options.
Other sizes available upon request
PbAll materials in
Nexans AmerCableAustralia’s mining
cables are lead free.
NominalArea(mm2)
NominalStrandSize
(#/mm)
NominalDiameter
Over Insulation(mm)
InsulationThickness(mm)
Semi-ConductiveCoveringThickness(mm)
NominalStrandSize
(min#/mm)
SheathThicknessIncludingSemi-
ConductiveCore Screen
(mm)
NominalOverallDiameter(mm)
Approx.Mass
(kg/100m)Part No.35-001-
016 16 133/0.40 3.0 14.6 69/0.25 1.0 5.0 45.1 253025 25 209/0.40 3.0 15.9 91/0.25 1.0 5.3 48.8 310035 35 285/0.40 3.0 17.1 140/0.25 1.0 5.6 51.6 364050 50 399/0.40 3.0 18.5 161/0.25 1.2 6.0 55.7 443070 70 342/0.51 3.0 20.6 69/0.51 1.2 6.4 61.2 581095 95 456/0.51 3.0 22.4 91/0.51 1.2 6.8 66.7 700120 120 627/0.51 3.0 24.8 112/0.51 1.2 7.2 71.4 857150 150 777/0.51 3.0 27.1 133/0.51 1.2 7.6 77.5 1020185 185 925/0.51 3.0 28.8 175/0.51 1.4 8.0 82.1 1183240 240 1221/0.51 3.0 31.1 196/0.51 1.4 8.6 88.3 1429300 300 1480/0.51 3.0 34.2 252/0.51 1.4 9.1 95.9 1700
Type 241.3 (3.3/3.3kV)
Type 241Mould-cured CPE Sheath • 3.3 - 11kV
4
Power Conductor Earth Conductor
NominalArea(mm2)
NominalStrandSize
(#/mm)
NominalDiameter
Over Insulation(mm)
InsulationThickness(mm)
Semi-ConductiveCoveringThickness(mm)
NominalStrandSize
(min#/mm)
SheathThicknessIncludingSemi-
ConductiveCore Screen
(mm)
NominalOverallDiameter(mm)
Approx.Mass
(kg/100m)Part No.35-002-016 16 133/0.40 5.0 18.7 69/0.25 1.4 6.1 56.4 366025 25 209/0.40 5.0 20 91/0.25 1.4 6.4 60.0 434035 35 285/0.40 5.0 21.2 140/0.25 1.4 6.7 62.8 490050 50 399/0.40 5.0 22.6 161/0.25 1.4 7.1 66.9 578070 70 342/0.51 5.0 24.5 69/0.51 1.4 7.4 71.6 707095 95 456/0.51 5.0 26.4 91/0.51 1.4 7.9 76.7 858120 120 627/0.51 5.0 28.7 112/0.51 1.4 8.3 82.5 1029150 150 777/0.51 5.0 31.1 133/0.51 1.4 8.6 88.3 1200185 185 925/0.51 5.0 32.9 175/0.51 1.4 9.0 93.0 1375240 240 1221/0.51 5.0 35.2 196/0.51 1.4 9.6 99.1 1630
Type 241.6 (6.6/6.6kV)Power Conductor Earth Conductor
NominalArea(mm2)
NominalStrandSize
(#/mm)
NominalDiameter
Over Insulation(mm)
InsulationThickness(mm)
Semi-ConductiveCoveringThickness(mm)
NominalStrandSize
(min#/mm)
SheathThicknessIncludingSemi-
ConductiveCore Screen
(mm)
NominalOverallDiameter(mm)
Approx.Mass
(kg/100m)Part No.35-003-
035 35 285/0.40 7.6 26.5 140/0.25 1.8 8.1 77.1 690050 50 399/0.40 7.6 28.1 161/0.25 1.8 8.5 81.5 796070 70 342/0.51 7.6 30.0 69/0.51 1.8 8.9 86.4 942095 95 456/0.51 7.6 31.8 91/0.51 1.8 9.3 91.1 1088120 120 627/0.51 7.6 34.2 112/0.51 1.8 9.7 97.1 1290150 150 777/0.51 7.6 36.6 133/0.51 1.8 10.0 102.9 1479
Type 241.11 (11/11kV)Power Conductor Earth Conductor
Phone 61 240 28 65 65 • Fax 61 240 28 65 66 • www.amercableaus.com
The Innovative Cable Solutions Company
Type 245Mould-cured CPE Sheath • 1.1-3.3kV
SummaryMainly used on longwall shearers. Cable has 3 central pilot cores for control circuits andearth continuity monitoring. Used also for continuous miners and peripheral longwall cables.
Nexans AmerCable Mining Cable meets orexceeds AS/NZS 1802 Standards.
SheathReinforced mould-cured heavy-duty thermosetting elastomer sheathHD-90-CPE
Cable identification via permanent marking
Conductors (3)Flexible tinned copper
InsulationEthylene-propylene rubber (EPR) R-EP-90
Earth Conductors (3)Semiconductiveelastomer coveredflexible tinned copper
Core Assembly ScreenSemiconductive elastomer
Central Pilot Core (3)EPR covered flexibletinned copper
Separator Tape1.1/1.1kV – polyester3.3/3.3kV and aboveuses semiconductivescreen
Insulation ScreenSemiconductive elastomer
Cradle SeparatorSemiconductiveelastomer
Put the Power of Nexans AmerCable in Your Mine
5
Standard cable
See pages 19-20 for other available
colours and striping options.
PbAll materials in
Nexans AmerCableAustralia’s mining
cables are lead free.
Type 245Mould-cured CPE Sheath • 1.1-3.3kV
NominalArea(mm2)
NominalStrandSize
(#/mm)
InsulationThickness(mm)
SheathThicknessIncludingSemi-
ConductiveCore Screen
(mm)
Semi-ConductiveCradle Finger
Thickness(mm)
NominalOverallDiameter(mm)
Approx.Mass
(kg/100m)Part No.35-010-016 16 133/0.40 2.0 12.2 69/0.25 1.8 6.2 4.1 42.6 235025 25 209/0.40 1.6 12.7 91/0.25 1.8 5.8 4.2 43.4 267035 35 285/0.40 1.6 13.8 140/0.25 1.4 5.6 4.4 45.6 311050 50 399/0.40 1.7 15.5 161/0.25 1.0 5.4 4.8 50.2 390070 70 342/0.51 1.8 17.5 69/0.51 1.0 5.1 5.1 54.8 501095 95 456/0.51 2.0 19.8 69/0.51 1.0 4.8 5.6 60.5 618120 120 627/0.51 2.1 22.4 69/0.51 1.2 4.7 6.0 66.8 779150 150 777/0.51 2.3 25.3 91/0.51 1.2 4.2 6.3 73.1 940
6
Power Conductor Earth Conductor
Type 245.1 (1.1/1.1kV)
NominalArea(mm2)
NominalStrandSize
(#/mm)
NominalDiameterOver
Insulation(mm)
InsulationThickness(#/mm)
Semi-ConductiveCoveringThickness(mm)
NominalStrandSize(min#/mm)
SheathThicknessIncludingSemi-
ConductiveCore Screen
(mm)
Semi-ConductiveCradle Finger
Thickness(mm)
NominalOverallDiameter(mm)
Approx.Mass
(kg/100m)Part No.35-011-025 25 209/0.40 3.0 15.9 91/0.25 1.5 5.4 5.2 51.1 335035 35 285/0.40 3.0 17.0 140/0.25 1.0 5.2 5.4 54.5 397050 50 399/0.40 3.0 18.5 161/0.25 1.0 5.0 5.7 58.2 474070 70 342/0.51 3.0 20.6 69/0.40 1.2 4.7 6.0 62.8 592095 95 456/0.51 3.0 22.4 91/0.51 1.2 4.4 6.4 68.3 739120 120 627/0.51 3.0 24.8 112/0.51 1.2 4.3 6.7 74.0 897150 150 777/0.51 3.0 27.1 133/0.51 1.2 3.9 7.0 77.9 1028
Power Conductor Earth Conductor
Type 245.3 (3.3/3.3kV)
Phone 61 240 28 65 65 • Fax 61 240 28 65 66 • www.amercableaus.com
Photo courtesy Joy
NominalStrandSize(min#/mm)
NominalDiameterOver
Insulation(mm)
Semi-ConductiveCoveringThickness(mm)
The Innovative Cable Solutions Company
Type 275Mould-cured CPE Sheath • 1.1kV
SummaryUsed for shuttle cars or other equipment withcable reels.
Nexans AmerCable Mining Cable meets orexceeds AS/NZS 1802 Standards.
Highly flexible construction with abrasion resistant CPE sheath. Available in colours and stripes.
Standard cable sheath is black.
See pages 19-20 for other available
colours and striping options.
SheathReinforced mould-cured heavy-duty thermosettingelastomer sheathHD-90-CPE
Cable identification via permanent marking
Conductors (3)Flexible tinned copper
Central Pilot CoreEPR covered extensibletinned copper
InsulationEthylene-propylene rubber(EPR) R-EP-90
Earth Conductors (3)Semiconductiveelastomer coveredflexible tinned copper
Separator TapePolyester
Core Assembly ScreenSemiconductive elastomer
Cradle SeparatorSemiconductive elastomer
7
Put the Power of Nexans AmerCable in Your Mine
PbAll materials in
Nexans AmerCableAustralia’s mining
cables are lead free.
Photo courtesy Joy
Type 275Mould-cured CPE Sheath • 1.1kV
NominalArea(mm2)
NominalStrandSize
(#/mm)
NominalDiameter
Over Insulation(mm)
InsulationThickness(mm)
Semi-ConductiveCoveringThickness(mm)
NominalStrandSize
(min#/mm)
SheathThicknessIncludingSemi-
ConductiveCore Screen
(mm)
NominalOverallDiameter(mm)
Approx.Mass
(kg/100m)Part No.35-004-025 25 209/0.40 1.6 10.9 120/0.32 1.0 4.0 37.0 215035 35 285/0.40 1.6 12.1 120/0.32 1.0 4.3 39.4 260
Other sizes available upon request
8
Power Conductor Earth Conductor
Type 275 (1.1/1.1kV)
If You Have a Special Requirement –Ask Your Nexans AmerCable Applications Engineer Today
Phone 61 240 28 65 65 • Fax 61 240 28 65 66 • www.amercableaus.com
The Innovative Cable Solutions Company
Type 441.1Mould-cured CPE Sheath • 1.1 kV
SummaryGeneral use cable with Class 2 insulation and sheath thicknesses used for open cut/surface mining applications such as dewatering pumps.
Nexans AmerCable Mining Cable meets orexceeds AS/NZS 2802 Standards.
Perfect for drill rigs in hard rock mining.
SheathReinforced mould-cured heavy duty thermosetting elastomer sheathXHD-90-CPE
Cable identification via permanent marking
Conductors (3)Flexible tinned copper
Central Pilot CoreEPR coveredextensible tinned copper
InsulationEthylene-propylene rubber (EPR) XR-EP-90
Earth Conductors (3)Semiconductiveelastomer coveredflexible tinned copper
Separator TapeNon-conductive
Core Assembly ScreenSemiconductive elastomer
Insulation ScreenSemiconductive elastomer
Cradle SeparatorSemiconductiveelastomer
9
Standard cable sheath is black.
See pages 19-20 for other available
colours and striping options.
NominalArea(mm2)
NominalStrandSize
(#/mm)
NominalDiameter
Over Insulation(mm)
InsulationThickness(mm)
Semi-ConductiveCoveringThickness(mm)
NominalStrandSize
(min#/mm)
SheathThicknessIncludingSemi-
ConductiveCore Screen
(mm)
NominalOverallDiameter(mm)
Approx.Mass
(kg/100m)Part No.35-012-006 6 84/0.30 1.5 8.5 42/0.25 0.8 3.8 29.8 111010 10 133/0.32 1.5 9.8 69/0.25 0.8 3.8 32.5 142016 16 133/0.40 1.6 11.3 105/0.25 1.0 3.9 36.1 185025 25 209/0.40 1.6 12.6 105/0.25 1.0 4.2 39.6 232035 35 285/0.40 1.6 13.6 140/0.25 1.0 4.4 43.8 276050 50 399/0.40 1.7 15.5 161/0.25 1.0 4.9 47.1 357070 70 342/0.51 1.8 17.5 69/0.51 1.0 5.3 52.3 473095 95 456/0.51 2.0 19.8 91/0.51 1.0 5.8 58.3 606120 120 627/0.51 2.1 22.4 112/0.51 1.0 6.3 64.7 779150 150 777/0.51 2.3 25.3 133/0.51 1.2 6.7 71.9 949185 185 925/0.51 2.5 27.3 175/0.51 1.2 7.3 77.5 1122240 240 1221/0.51 2.8 30.2 196/0.51 1.2 8.0 85.2 1393300 300 1480/0.51 3.0 33.8 252/0.51 1.4 8.7 94.2 1693
Power Conductor Earth Conductor
Type 441.1 (1.1/1.1kV)
PbAll materials in
Nexans AmerCableAustralia’s mining
cables are lead free.
Phone 61 240 28 65 65 • Fax 61 240 28 65 66 • www.amercableaus.com 10
Type 441.6Mould-cured CPE Sheath • 6.6 kV
SummaryMultiple use cable with Class 1 insulation andsheath thicknesses. Cable can be used as atrailing cable for shovels, drills, and other reeling applications.
AmerCable Mining Cable meets or exceedsAS/NZS 2802 Standards.
SheathReinforced mould-cured heavy duty thermosetting elastomer sheathXHD-90-CPE
Cable identification via permanent marking
Conductors (3)Flexible tinned copper
Central Pilot CoreEPR coveredextensible tinned copper
InsulationEthylene-propylene rubber (EPR) XR-EP-90
Earth Conductors (3)Semiconductiveelastomer coveredflexible tinned copper
Core Assembly ScreenSemiconductive elastomer
Insulation ScreenSemiconductive elastomer
Cradle SeparatorSemiconductiveelastomer
NominalArea(mm2)
NominalStrandSize
(#/mm)
NominalDiameter
Over Insulation(mm)
InsulationThickness(mm)
Semi-ConductiveCoveringThickness(mm)
NominalStrandSize
(min#/mm)
SheathThicknessIncludingSemi-
ConductiveCore Screen
(mm)
NominalOverallDiameter(mm)
Approx.Mass
(kg/100m)Part No.35-014-016 16 133/0.40 3.0 15.5 105/0.25 1.0 5.0 47.3 276025 25 209/0.40 3.0 16.8 105/0.25 1.0 5.3 50.6 332035 35 285/0.40 3.0 17.8 105/0.25 1.0 5.6 53.5 361050 50 399/0.40 3.0 19.4 161/0.25 1.2 6.0 57.6 464070 70 342/0.51 3.0 21.3 69/0.40 1.2 6.3 62.2 583095 95 456/0.51 3.0 23.1 91/0.51 1.2 6.4 66.3 696120 120 627/0.51 3.0 25.5 112/0.51 1.2 6.6 72.2 868150 150 777/0.51 3.0 27.9 133/0.51 1.2 6.7 77.6 1021185 185 925/0.51 3.0 29.6 175/0.51 1.4 6.8 81.4 1169240 240 1221/0.51 3.0 32.0 196/0.51 1.4 7.0 87.0 1403300 300 1480/0.51 3.0 35.1 252/0.51 1.4 7.1 93.4 1650
Power Conductor Earth Conductor
Type 441.6 (6.6/6.6kV)
Conductive ScreenSemiconductive tape and extruded semiconductive layer
Standard cable sheath is black.
ee pages 19-20 for other available
colours and striping options.
PbAll materials in
Nexans AmerCableAustralia’s mining
cables are lead free.
The Innovative Cable Solutions Company
Type 441.11Mould-cured CPE Sheath • 11kV
SummaryMultiple use cable with Class 1 insulation andsheath thicknesses. Cable can be used as atrailing cable for shovels, drills, bucket heelexcavator and other reeling applications.
Nexans AmerCable Mining Cable meets orexceeds AS/NZS 2802 Standards.
SheathReinforced mould-cured extra heavy duty thermosetting elastomer sheathXHD-90-CPE
Cable identification via permanent marking
Conductors (3)Flexible tinned copper
Central Pilot CoreEPR coveredextensible tinned copper
InsulationEthylene-propylene rubber (EPR) XR-EP-90
Earth Conductors (3)Semiconductiveelastomer coveredflexible tinned copper
Core Assembly ScreenSemiconductive elastomer
Insulation ScreenSemiconductive elastomer
Cradle SeparatorSemiconductiveelastomer
NominalArea(mm2)
NominalStrandSize
(#/mm)
NominalDiameter
Over Insulation(mm)
InsulationThickness(mm)
Semi-ConductiveCoveringThickness(mm)
NominalStrandSize
(min#/mm)
SheathThicknessIncludingSemi-
ConductiveCore Screen
(mm)
NominalOverallDiameter(mm)
Approx.Mass
(kg/100m)Part No.35-015-025 25 209/0.40 5.0 20.8 105/0.25 1.2 6.3 61.4 452035 35 285/0.40 5.0 21.8 105/0.25 1.4 6.4 63.8 501050 50 399/0.40 5.0 23.5 161/0.25 1.4 6.5 67.6 588070 70 342/0.51 5.0 25.4 69/0.51 1.4 6.6 71.6 705095 95 456/0.51 5.0 27.2 91/0.51 1.4 6.8 75.8 845120 120 627/0.51 5.0 29.6 112/0.51 1.4 6.9 81.6 1011150 150 777/0.51 5.0 32.0 133/0.51 1.4 7.0 87.0 1177240 240 1221/0.51 5.0 36.1 196/0.51 1.4 7.3 96.3 1572
Other sizes and voltages available upon request
Power Conductor Earth Conductor
Type 441.11 (11/11kV)
Conductive ScreenSemiconductive tape and extruded semiconductive layer
Standard cable sheath is black.
See pages 19-20 for other available
colours and striping options.
PbAll materials in
Nexans AmerCableAustralia’s mining
cables are lead free.
11
Phone 61 240 28 65 65 • Fax 61 240 28 65 66 • www.amercableaus.com 12
Type 441.22Mould-cured CPE Sheath • 22kV
SummaryMultiple use cable with Class 1 insulation andsheath thicknesses. Cable is used primarily asa trailing cable for draglines.
AmerCable Mining Cable meets or exceedsAS/NZS 2802 Standards.
SheathReinforced mould-cured heavy-duty thermosetting elastomer sheathXHD-90-CPE
Cable identification via permanent marking
Conductors (3)Flexible tinned copper
Central Pilot CoreEPR coveredextensible tinned copper
InsulationEthylene-propylene rubber (EPR) XR-EP-90
Earth Conductors (3)Semiconductiveelastomer coveredflexible tinned copper
Core Assembly ScreenSemiconductive elastomer
Insulation ScreenSemiconductive elastomer
Cradle SeparatorSemiconductiveelastomer
NominalArea(mm2)
NominalStrandSize
(#/mm)
NominalDiameter
Over Insulation(mm)
InsulationThickness(mm)
Semi-ConductiveCoveringThickness(mm)
NominalStrandSize
(min#/mm)
SheathThicknessIncludingSemi-
ConductiveCore Screen
(mm)
NominalOverallDiameter(mm)
Approx.Mass
(kg/100m)Part No.35-016-035 35 285/0.40 7.6 27.3 140/0.25 1.8 6.9 76.3 679120 120 627/0.51 7.6 34.9 112/0.51 1.8 7.3 93.8 1224
Other sizes and voltages available upon request
Power Conductor Earth Conductor
Type 441.22 (22/22kV)
Conductive ScreenSemiconductive tape and extruded semiconductive layer
Standard cable sheath is black.
See pages 19-20 for other available
colours and striping options.
PbAll materials in
Nexans AmerCableAustralia’s mining
cables are lead free.
If You Have a Special Requirement –Ask Your Nexans AmerCable Applications Engineer
The Innovative Cable Solutions Company
Enhanced Type 441 (SCR)Mould-cured CPE Sheath • 3.3kV
SummaryFully compliant Type 441 construction toAS/NZS 2802 offered in 3.3kV-22kV with the added earthing protection of a braidedtinned copper shielding system which is fully compliant to the Australian StandardType 450 cable.
n Provides additional earthing protection inhigh fault current situations
n Provides additional mechanical protectionwith the additional metallic shielding
n Class 1 insulation on 3.3kV cablesand above
SheathReinforced mould-cured heavy duty thermosetting elastomer sheathXHD-90-CPE
Cable identification via permanent marking
Conductors (3)Flexible tinned copper
Central Pilot CoreEPR coveredextensible tinned copper
InsulationEthylene-propylene rubber (EPR) XR-EP-90
Earth Conductors (3)Semiconductiveelastomer coveredflexible tinned copper
Core Assembly ScreenSemiconductive elastomer
Insulation ScreenSemiconductive elastomer
Cradle SeparatorSemiconductiveelastomer
Conductive ScreenExtruded semi-conductive layer
Standard cable sheath is black.
See pages 19-20 for other available
colours and striping options.
Braid ShieldPer type 450TapeSemiconducting
PbAll materials in
Nexans AmerCableAustralia’s mining
cables are lead free.
13
NominalArea(mm2)
NominalStrandSize
(#/mm)
NominalDiameter
Over Insulation(mm)
InsulationThickness(mm)
Semi-ConductiveCoveringThickness(mm)
NominalStrandSize
(min#/mm)
SheathThicknessIncludingSemi-
ConductiveCore Screen
(mm)
NominalOverallDiameter(mm)
Approx.Mass
(kg/100m)Part No.35-018-016 16 133/0.40 2.2 13.8 105/0.25 1.1 4.6 46.4 282025 25 209/0.40 2.2 15.3 105/0.25 1.1 4.9 50.1 343035 35 285/0.40 2.2 16.4 105/0.25 1.1 5.2 53.0 394050 50 399/0.40 2.4 18.3 105/0.25 1.1 5.7 58.4 487070 70 342/0.51 2.4 20.1 108/0.40 1.1 6.0 63.3 617095 95 456/0.51 2.4 21.8 91/0.51 1.3 6.3 67.7 733120 120 627/0.51 2.4 24.3 112/0.51 1.3 6.5 73.5 906150 150 777/0.51 2.4 26.8 133/0.51 1.3 6.6 78.9 1089
Other sizes and voltages available upon request
Power Conductor Earth Conductor
Type 441.3 (3.3kV)
Phone 61 240 28 65 65 • Fax 61 240 28 65 66 • www.amercableaus.com 14
Enhanced Type 441 (SCR)Mould-cured CPE Sheath • 6.6 – 22kV
NominalArea(mm2)
NominalStrandSize
(#/mm)
NominalDiameter
Over Insulation(mm)
InsulationThickness(mm)
Semi-ConductiveCoveringThickness(mm)
NominalStrandSize
(min#/mm)
SheathThicknessIncludingSemi-
ConductiveCore Screen
(mm)
NominalOverallDiameter(mm)
Approx.Mass
(kg/100m)Part No.35-019-016 16 133/0.40 3.00 15.4 105/0.25 1.1 5.0 50.8 329025 25 209/0.40 3.00 16.9 105/0.25 1.1 5.3 54.5 385035 35 285/0.40 3.00 17.9 105/0.25 1.1 5.6 57.3 444050 50 399/0.40 3.00 19.4 161/0.25 1.3 6.0 61.8 544070 70 342/0.51 3.00 21.3 108/0.40 1.3 6.3 66.7 666095 95 456/0.51 3.00 23.1 91/0.51 1.3 6.4 70.7 796120 120 627/0.51 3.00 25.5 112/0.51 1.3 6.6 76.6 962150 150 777/0.51 3.00 27.4 133/0.51 1.3 6.7 80.5 1070
Other sizes and voltages available upon request
Power Conductor Earth Conductor
Type 441.6 (6.6/6.6kV)
NominalArea(mm2)
NominalStrandSize
(#/mm)
NominalDiameter
Over Insulation(mm)
InsulationThickness(mm)
Semi-ConductiveCoveringThickness(mm)
NominalStrandSize
(min#/mm)
SheathThicknessIncludingSemi-
ConductiveCore Screen
(mm)
NominalOverallDiameter(mm)
Approx.Mass
(kg/100m)Part No.35-020-025 25 209/0.40 5.0 20.9 105/0.25 1.3 6.3 65.5 538035 35 285/0.40 5.0 22.0 105/0.25 1.5 6.4 69.6 618050 50 399/0.40 5.0 23.6 161/0.25 1.5 6.5 71.9 683070 70 342/0.51 5.0 25.5 108/0.40 1.5 6.6 76.0 809095 95 456/0.51 5.0 27.2 91/0.51 1.5 6.8 79.8 924120 120 627/0.51 5.0 29.7 112/0.51 1.5 6.9 85.8 1107150 150 777/0.51 5.0 31.5 133/0.51 1.5 7.0 90.3 1281185 185 925/0.51 5.0 33.2 175/0.51 1.5 7.1 94.2 1441240 240 925/0.51 5.0 36.3 196/0.51 1.5 7.3 101.3 1730300 300 1480/0.51 5.0 38.4 252/0.51 1.9 7.4 109.3 2059
Other sizes and voltages available upon request
Power Conductor Earth Conductor
Type 441.11 (11/11kV)
NominalArea(mm2)
NominalStrandSize
(#/mm)
NominalDiameter
Over Insulation(mm)
InsulationThickness(mm)
Semi-ConductiveCoveringThickness(mm)
NominalStrandSize
(min#/mm)
SheathThicknessIncludingSemi-
ConductiveCore Screen
(mm)
NominalOverallDiameter(mm)
Approx.Mass
(kg/100m)Part No.35-021035 35 285/0.40 7.6 27.4 105/0.25 1.9 6.8 80.7 748050 50 399/0.40 7.6 29.0 161/0.25 1.9 7.0 84.4 881070 70 342/0.51 7.6 28.5 108/0.40 2.0 7.1 88.7 1034095 95 456/0.51 7.6 32.6 91/0.51 1.9 7.2 93.3 1189120 120 627/0.51 7.6 34.9 112/0.51 1.9 7.3 98.9 1370150 150 777/0.51 7.6 37.0 133/0.51 1.9 7.4 103.1 1532185 185 925/0.51 7.6 38.5 175/0.51 2.0 7.5 106.4 1727240 240 925/0.51 7.6 41.7 196/0.51 2.2 7.7 113.9 2028
Other sizes and voltages available upon request
Power Conductor Earth Conductor
Type 441.22 (22/22kV)
The Innovative Cable Solutions Company
Type 450 (SCR)Mould-cured CPE Sheath • 6.6 – 22kV
SummaryType 450 construction to AS/NZS 2802offered in 6.6kV-22kV with the added earth-ing protection of a braided tinned copper shielding system which is fully compliant tothe Australian Standard Type 450 cable.
n Provides additional earthing protection inhigh fault current situations
n Provides additional mechanical protectionwith metallic shielding
n Class 1 insulation
Conductors (3)Flexible tinned copper
InsulationEthylene-propylene rubber (EPR) XR-EP-90
Earth Conductors (2)Semiconductiveelastomer coveredflexible tinned copper
SheathReinforced mould cured extra heavy duty thermosetting elastomer sheathXHD-90-CPE
Cable identification via permanent marking
Insulation ScreenSemiconductive elastomer
FillerRubber required to fillthe center interstice
TapeSemiconducting
Conductive ScreenExtruded semi-conductive layer
PilotElastomer coveredflexible tinned copper
Standard cable sheath is black.
Braid ShieldPer Type 450TapeSemiconducting
PbAll materials in
Nexans AmerCableAustralia’s mining
cables are lead free.
15
Phone 61 240 28 65 65 • Fax 61 240 28 65 66 • www.amercableaus.com
Part No.35-025-
095120
95120
456/0.51627/0.51
3.03.0
21.423.8
0.400.40
25.027.6
175/0.51175/0.51
2.22.3
6.46.5
67.072.4
78829953
Power ConductorPilot/EarthConductor
Type 450.6 (6kV)
NominalArea(mm2)
NominalStrandSize
(#/mm)
InsulationThickness(mm)
NominalDiameterOver
Insulation(mm)
CompositeScreenWire
Diameter(mm)
NominalDiameterOver
CompositeScreen (mm)
Nom.StrandSize(min#/mm)
ElastomerCoveringThickness(mm)
SheathThickness(mm)
NominalOverallDiameter(mm)
Approx.Mass(kg/km)
Part No.35-023-
095120
95120
456/0.51627/0.51
5.05.0
25.427.8
0.400.40
29.031.3
175/0.51175/0.51
2.703.25
6.76.9
76.281.7
982110847
Power ConductorPilot/EarthConductor
Type 450.11 (11kV)
NominalArea(mm2)
NominalStrandSize
(#/mm)
InsulationThickness(mm)
NominalDiameterOver
Insulation(mm)
CompositeScreenWire
Diameter(mm)
NominalDiameterOver
CompositeScreen (mm)
Nom.StrandSize(min#/mm)
ElastomerCoveringThickness(mm)
SheathThickness(mm)
NominalOverallDiameter(mm)
Approx.Mass(kg/km)
Part No.35-026-
095120185
95120185
456/0.51627/0.51925/0.51
7.67.67.6
30.833.236.7
0.500.500.50
34.636.940.6
175/0.51175/0.51304/0.51
4.004.504.00
7.27.37.6
89.494.7102.9
115051431417935
Power ConductorPilot/EarthConductor
Type 450.22 (22kV)
NominalArea(mm2)
NominalStrandSize
(#/mm)
InsulationThickness(mm)
NominalDiameterOver
Insulation(mm)
CompositeScreenWire
Diameter(mm)
NominalDiameterOver
CompositeScreen (mm)
Nom.StrandSize(min#/mm)
ElastomerCoveringThickness(mm)
SheathThickness(mm)
NominalOverallDiameter(mm)
Approx.Mass(kg/km)
16
The Innovative Cable Solutions Company17
Mine SafeFeeder Cable
Summaryn Lighter weightn Super Tough HD CPE Sheathsn A uniquely identifiable outer sheath with
a RED CPE stripe helically applied andbonded into the HD Black CPE jacket
n Better earthing protection in phase-to-phase fault and phase-to-earth fault situations than with 241
n The superior earthing comes from a combination of state-of-the-art semiconducting materials and a braided earth shield
n Tinned copper shields provide mechanicalcoverage and minimise any possible shield wire voids. Shield wire integrity is enhanced by interwinding colour coded nylon braid
Safety Firstn Lighter, smaller and uniquely identifiable
SheathReinforced mould-cured heavy duty thermosetting elastomer sheathHD-90-CPE
Cable identification via permanent marking
AssemblyThree power cores andthree pilot coresassembled around anelastomer center filler
Conductors (3)Flexible tinned copper
Pilot Cores (3)EPR/CPE coveredflexible tinned copper
InsulationEthylene-propylene rubber (EPR) R-EP-90
Insulation ScreenSemiconductive elastomer
Standard cable sheath isblack/red.
Copper ShieldPer Type 450
PbAll materials in
Nexans AmerCableAustralia’s mining
cables are lead free.
NominalArea(mm2)
NominalStrandSize
(#/mm)
NominalDiameter
Over Insulation(mm)
InsulationThickness(mm)
Insulation/CoveringThickness(mm)
NominalStrandSize
(min#/mm)
SheathThicknessIncludingSemi-
ConductiveCore Screen
(mm)
NominalOverallDiameter(mm)
Approx.Mass
(kg/100m)Part No.35-022-016 16 133/0.40 1.4 9.1 19/0.47 0.8 2.5 27.3 149025 25 209/0.40 1.4 10.4 19/0.47 1.0 2.5 30.2 193035 35 285/0.40 1.5 11.7 19/0.47 1.0 2.5 33.0 220050 50 399/0.40 1.7 13.7 37/0.42 1.0 3.0 39.8 328070 70 342/0.51 1.8 15.8 37/0.42 1.0 3.3 44.9 421095 95 456/0.51 2.0 18.1 37/0.42 1.0 3.8 50.8 548120 120 627/0.51 2.2 20.9 37/0.42 1.0 3.8 60.5 740150 150 777/0.51 2.3 22.9 37/0.42 1.0 4.4 62.6 840185 185 925/0.51 2.5 24.9 37/0.42 1.0 5.1 73.4 1041240 240 1221/0.51 2.7 28.4 37/0.42 1.0 5.7 78.8 1326
Power ConductorPilot Cores
(Type A Feeder Cables Only)
Type A (1.1kV)
18Phone 61 240 28 65 65 • Fax 61 240 28 65 66 • www.amercableaus.com
Engineering &Technical SupportMine safety and maximum cable productivity are Nexans AmerCable’stop priorities for our customers.
Underground or Open Cut, Nexans AmerCable’s experienced applications engineers are ready to provide on-site cable evaluation, training and innovative product solutions.
A few extra minutes spent in training can save hoursof costly downtime.
Cable Handling Best PracticesSometimes, getting the most life out of your mining cablesmeans learning how to transport and deploy them correctly.
Our applications engineers can conduct on-site training on the best ways to handle and deploy power cables to extend their service life, reduce down time and enhance safety in your mine.
MineCable-Safeis an investment in Safety and Productivity that brings the knowledge and experience of our applications engineers to your mine.
MineCable-SafeFor Underground or
Open Cut Mines
Safe Cable Practices
Worker Safety
Extended Cable Life
The Innovative Cable Solutions Company19
CPE Only
Black/White Blue/Green Yellow/Blue Orange/White Red/Blue Black/Green
Safety in Colours & Stripes
Black/Red(MSFC only)
Blue/White Red/White Green/White
Nexans AmerCable provides additional colour combinations by vulcanising a contrasting coloured stripe into the sheath of our round CPE cables.
Shown below are a few examples of the many possible sheath / stripe combinations.Consult with your AmerCable applications engineer for a complete list of available stripe options.
Have youbeen striped?
Available only from Nexans AmerCable
Improved Safetythrough easier
circuit identification
Specific colours for specific equipment
Striped CablesAvailable only
on CPEsheathed cables
20Phone 61 240 28 65 65 • Fax 61 240 28 65 66 • www.amercableaus.com
Sheaths
Black(Standard)
Blue Green Orange Yellow Red
CPE Colours
Nexans AmerCable CPE SheathsNexans AmerCable’s thermoset Chlorinated Polyethylene (CPE) sheath provides the physical performance and strength needed to resist wear, tear, abrasion and compression cuts caused byeveryday mining use.
This tough, durable sheath is a proven performer in mines throughout the world. NexansAmerCable’s engineered cable construction includes a taped-core with fillers or integral filled andtandem extrusion of the sheath layers. Two-pass sheaths, extruded in tandem, yield an inseparablebond between the layers. Integral filling of the cable core reduces torsion-induced damage.
Nexans AmerCable’s CPE colored sheaths have the identical physical properties of our standardblack sheath. These high visibility cables can improve mine safety by providing easy circuit identification.
Photo courtesy Bucyrus
The Innovative Cable Solutions Company
MechanicalInformation
Recommended Minimum Cable Bending RadiusBend rating x nominal overall cable diameter = Minimum Bending Recommendation
(unless otherwise specified)
Unarmored CablesRated 1.1/1.1kV
Application Unarmored CablesRated 3.3/3.3kV and Above
Delivery Drum 5 7
Fixed Bend 4 6
Free Flexing 6 10
Permanently Repeating Reeling 10 12
Sheave Pass Over 10 16
Rating FactorAmbient Air Temperature ˚C
ConductorTemp ˚C 15 20 25 30 35 40 45 50 55 60
75 1.35 1.28 1.21 1.14 1.07 1.0 0.91 0.82 0.72 0.6090 1.26 1.20 1.15 1.10 1.05 1.0 0.94 0.88 0.81 0.73
Reel Correction FactorsFor use with ampacities when one or more layers of cable are wound on a reel. Cables must be derated to prevent over-heating.
Higher/LowerTemperature FactorsIf trailing cables are exposed to higher or lowertemperatures in underground applications,apply these rating factors for current capacity.
DeratingNo. of Layers Factor
Cylindrical Drum1234
VentilatedUnventilated
0.850.75
0.850.650.450.35
Radial Drum
Bending RadiusOne of the most common causes of cable failure is exceeding Nexans AmerCable’s recommendedbend radius. Exceeding the recommended bend radius can damage the conductor, pilot and insulation. Since this is normally not visible, this damage will result in unexpected cable failure andcostly downtime.
21
22
MechanicalInformation
Reactance Values241.1
Conductor SizeNominal mm2
Reactance50 Hz, ohm to
neut/km
Capacitance10-9 faradper km
610162535507095
120150185240300
0.1360.1220.1150.1080.1030.09820.09400.09160.08800.08780.08670.08340.0839
247.3318.0359.3429.6478.8528.4582.9602.0663.0680.2706.9703.3739.9
Reactance Values241.3
Conductor SizeNominal mm2
Reactance50 Hz, ohm to
neut/km
Capacitance10-9 faradper km
162535507095
120150185240300
0.1280.1200.1140.1080.1030.09820.09380.09160.08990.08500.0848
242.5278.5305.4348.4397.1445.6507.3570.9615.2675.3735.3
Reactance Values241.6
Conductor SizeNominal mm2
Reactance50 Hz, ohm to
neut/km
Capacitance10-9 faradper km
162535507095
120150185240
0.1410.1320.1260.1180.1120.1070.1020.09950.09730.0921
171.3193.8210.5237.1267.0296.8334.6373.3400.3436.9
Phone 61 240 28 65 65 • Fax 61 240 28 65 66 • www.amercableaus.com
Pulling TensionsAnother common cause of failure is excessive tension. Pulling too long of lengths, especially in a small radius will de-cable the power conductorsand cause the cable to kink.
Electrical Information
RecommendedPulling Force
Application All VoltagesStraight Pull
Pull Around a Radius20N/mm215N/mm2
ElectricalInformation
Reactance Values245.1
Conductor SizeNominal mm2
Reactance50 Hz, ohm to
neut/km
Capacitance10-9 faradper km
162535507095
120150
0.1320.1200.1130.1070.1010.09730.09350.0916
304.5429.5478.8528.4582.9602.0663.0680.2
Reactance Values245.3
Conductor SizeNominal mm2
Reactance50 Hz, ohm to
neut/km
Capacitance10-9 faradper km
2535507095
120150
0.1260.1220.1150.1080.1030.09760.0943
278.5305.4348.4397.1445.6507.3570.9
Reactance Values275
Conductor SizeNominal mm2
Reactance50 Hz, ohm to
neut/km
Capacitance10-9 faradper km
16253550
0.1070.1010.09590.0924
427.7513.5572.0621.8
Reactance Values441.1
Conductor SizeNominal mm2
Reactance50 Hz, ohm to
neut/km
Capacitance10-9 faradper km
610162535507095
120150185240300
0.1360.1220.1150.1080.1030.09820.09400.09160.08800.08780.08670.08340.0839
247.3318.0359.3429.6478.8528.4582.9602.0663.0680.2706.9703.3739.9
23 The Innovative Cable Solutions Company
Photo courtesy Joy
Reactance Values241.11
Conductor SizeNominal mm2
Reactance50 Hz, ohm to
neut/km
Capacitance10-9 faradper km
2535507095
120150
0.1450.1380.1300.1230.1180.1120.109
147.8159.2177.2197.5217.5242.7268.6
ElectricalInformation
24
Reactance Values441.6 & 441.6 Enhanced SCRConductor Size
Nominal mm2
Reactance50 Hz, ohm to
neut/km
Capacitance10-9 faradper km
162535507095
120150240
0.1360.1280.1220.1150.1090.1040.1000.09590.0935
262.4300.8329.6370.6419.2467.7527.4604.2450.1
Reactance Values441.11& 441.11 Enhanced SCRConductor Size
Nominal mm2
Reactance50 Hz, ohm to
neut/km
Capacitance10-9 faradper km
2535507095
120150185240300
0.1390.1340.1250.1180.1130.1070.1040.1010.09700.0946
205.7225.3250.6280.4310.0347.7378.8403.8452.6486.4
Phone 61 240 28 65 65 • Fax 61 240 28 65 66 • www.amercableaus.com
Reactance Values441.22 & 441.22 Enhanced SCRConductor Size
Nominal mm2
Reactance50 Hz, ohm to
neut/km
Capacitance10-9 faradper km
35507095
120150185240
0.1440.1360.1290.1230.1170.1130.1100.106
169.2186.3206.6226.3251.6272.2289.0321.4
Reactance Values441.3 & 441.3 Enhanced SCRConductor Size
Nominal mm2
Reactance50 Hz, ohm to
neut/km
Capacitance10-9 faradper km
162535507095
120150185240300
0.1310.1230.1180.1120.1060.1010.09700.09480.08890.08420.0839
328.3379.5417.9445.4506.1579.2643.5651.1778.8853.9952.9
Shuttle Car Cable AnchorsProper UseSC Anchor should be 3 metre minimum from passing shuttle car.• Spreads high tension over more cable• Reduces shock loading of soft-drawn copper conductors
• Can eliminate extremely tight bend aroundtop of batwing
Cable Anchor TooClose to Feeder Cable
Too Close to Anchor
No!No!
The Innovative Cable Solutions Company
ElectricalInformation
Reeling & Trailing Cables
Nominal Area
mm2
Conductor DC ACNotional Resistance Resistance Volt Drop Fault CurrentStrand @20˚C @90˚C milli-Volt/ 1 SecondNo/mm Ω/km Ω/km Amp/meter 3-Phase kA
6 84/0.30 3.20 4.08 7.07 0.85910 133/0.32 1.78 2.26 3.91 1.4316 133/0.40 1.14 1.45 2.51 2.2925 209/0.40 0.722 0.920 1.61 3.5835 287/0.40 0.527 0.672 1.18 5.0150 399/0.51 0.379 0.484 0.857 7.1670 342/0.51 0.267 0.340 0.615 10.0095 456/0.51 0.200 0.255 0.473 13.60
120 627/0.51 0.145 0.186 0.360 17.20150 777/0.51 0.117 0.151 0.305 21.50185 925/0.51 0.0986 0.127 0.268 26.50240 1221/0.51 0.0747 0.0965 0.222 34.40300 1480/0.51 0.0616 0.0801 0.201 43.00
Reeling & Trailing Cables Amperes – Continuous Current
Conductor Size
mm2
1.1/1.1kV 3.3/3.3 - 33/33kV 1.1/1.1kV 3.3/3.3 - 33/33kV1.5 23 - 18 -2.5 30 - 23 -6 53 - 40 -10 70 - 53 -16 95 97 73 7225 128 128 96 9535 152 152 115 11050 191 191 141 13670 220 220 160 15595 265 265 196 190120 321 321 227 221150 363 363 261 257185 395 395 284 280240 455 455 327 324300 520 520 374 371
Current Carrying Capacities
General
In accordance with IEC60287 for the free air condition based on a conductor temperature of 90°C, and an ambient air temperature of 40°C, a solar radiation absorption coefficient of 0.8 and an intensity of 1000 W/m2, where exposed to direct sunlight, the following current carrying capacities should be adopted:
Protected from SunCable Voltage Rating
Exposed to SunCable Voltage Rating
25
Manufacturing
Nexans AmerCable is the leading global manufacturer of open cut andunderground mining cables. Our manufacturing facility is located in El Dorado, Arkansas, United States of America.
Nexans AmerCable is an ISO 9001 certified cable manufacturer that combines leading-edge technology, proven manufacturing techniques andhigh quality service to deliver the finest mining cable products available.
Nexans AmerCable has earned the following international mining 3rd party testing certifications:• AS/NZS • MSHA • CSA • GOST • MA • SABS • IEC
More than any other international cable supplier!
AS/NZS
Phone 61 240 28 65 65 • Fax 61 240 28 65 66 • www.amercableaus.com 26
7_13© 2013, AmerCable Incorporated
Unit 5, 10 Enterprise Drive, Beresfield NSW Australia 2322 • Phone 61 240 28 65 65 • Fax 61 240 28 65 66
Low smoke halogen-free fire resistantor flame retardant Type P cables.
Foil shielded, powercables engineered for use in variable frequency AC driveapplications.Available in several constructions
Crush and ImpactResistant Type Pcables withoutexternal armoring.
Single and 2/conductor600V and 2000V.Flexible, reliable andtightest diameter tolerances. PV cables.AmerSol dual-certified(TÜV and UL).
Innovative Cable Solutions for the Resources Mining and Energy Industries
Innovative Cable Solutions for the Resources Mining and Energy Industries
Contact your Nexans AmerCable Representative