8/10/2019 Griflam_gb de Messer-1
1/90
GRIFLAM Heating Technology
What does GRIFLAMoffer?
We have developed the new GRIFLAM product range with a broad spectrum of highquality products to meet the multi-faceted demands for heating work-pieces with the Oxy-fuel flame, so that the user is always offered the optimum solution for all heatingprocesses bearing their specific production parameters in mind.
The GRIFLAM product range includes a large number of heating inserts and heatingtorches which can be individually used to suit the type of gas, the necessary torchgeometry and the thermal output of the flame required for a specific heat transfer. Withhandles for manual use and shafts for mechanised applications we can offer torches forevery output level in combination with products from the MINITHERM, STAR, STARLETand SUPERTHERM range. The accessories needed for optimum use of the heatingtorches, such as supply hoses, safety equipment, setting valves etc. are an integral partof our GRIFLAMproduct range.
Complete solutions for individual requirements are the characteristic of theGRIFLAMrange. Our project team is always at your disposal for advice and support.
In addition, GRIFLAM
offers the service of individual production which can be modifiedto suit specific customer requirements. The manufacture of heating inserts and torches inspecial lengths or with special head angles is also part of GRIFLAM , as is thedevelopment and production of complete heating units for automatically controlledheating processes, e.g. for exactly controlled cycle times. As well as heating torches,which are the core of such a unit, we also, of course, supply the associated equipment.Gas supply units and control, ignition and monitoring equipment round off the range andmake our GRIFLAM heating technology to complete and indispensable partner, for allprojects involving heating with the Oxy-fuel flame.
In this catalogue we present to you our entire GRIFLAMstandard range with over 750
high quality products, most of which are available ex stock. Naturally, we will inform youof the delivery times when issuing quotations and order acknowledgements. Please quoteour part number and item description when ordering. Supply is subject to our terms andconditions of sale.
You will find a questionnaire in the appendix to this catalogue. This will help you to solveyour heating problems. Please send this questionnaire, duly completed; we will prepareyou a free offer, without obligation quickly.
We are sure that you will find innovative ideas for your heating applications in ourGRIFLAMcatalogue.
8/10/2019 Griflam_gb de Messer-1
2/90
GRIFLAM Heating TechnologyFuel Gases:
The heating process and the required temperature height determine notonly the choice of heating torch, but also the choice of fuel gas used. Theshape of the heating torch and ist distance to the job influence the heatdistribution.
The flame temperature can be varied by altering the mixing ration of fuelgas / air or fuel gas / Oxygen.
However, not only the flame temperature but also the burning speed ofthe gas is decisive for the selection of the gas mixture. For these factors,too influence the distribution of heat and the time to heat the job.
DensityType of fuel gas Lower thermalvalue hu
Flame temperature[C] 1 bar u. 15C Liquid
Description ID colour [kJ/m3] [kJ/kg] norm. max. stch. [kg/m3] [kg/l]
Hydrogen Red 10.758 119.533 2835 2856 2840 0,09 0,07
Methane Red 31.814 44.186 2770 2786 2778 0,72 0,42Acetylene Yellow 56.930 48.678 3106 3160 3066 1,17 0,62GRIESON Red 55.674 47.600 2902 2924 2902 1,17 0,57
MAPP Red 89.999 46.153 2872 2896 2878 1,95 0,58Propane Orange 93.557 46.315 2810 2828 2820 2,02 0,53
Mixing ratio for torch operation in the atmosphereAcetylene (A) GRIESON (F) MAPP (Y) Methane (M)
(Natural gas)Propane
(P)Hydrogen (H)
Fuel gas : Oxygenm3 : m3
1 : 1,1 1 : 1,9 1 : 3,0 1 : 1,6 1 : 3,75 1 : 0,36
Fuel gas : Airm3 : m3
1 : 5,5 1 : 9,5 1 : 15 1 : 8 1 : 19 1 : 1,8
The volumes in m3 refer to NTP as defined in DIN 1343.
0500
100015002000250030003500
T [C]
Acetylene
GRIESON
MAPP
Methane
Propane
Hydrogen
Fuel gas
Maximum Flame Temperature of different fuel gases
Oxygen
Compressedair
Temperatures of variousHeating processes
C Application
2200 Melting ofQuarz glass
1800 ShapingQuarz glass
1100 Fusing of powdercoatings
1000 Shaping of Steel
850 Flame hardening
800 Shaping of Copper
Preheating of Copper forwelding
700Hard soldering (Flame
brazing)
Flame straightening andnormalising of steel
600Heat treatment of
Copper
400 Shaping Aluminiumalloys
Preheating steel forwelding and cutting
200 Preheating Aluminiumalloys for welding
8/10/2019 Griflam_gb de Messer-1
3/90
GRIFLAM Heating Technology
Assembly of a heating unit
Pilot ignition torch, page 59, 60With electric ignition and monitoring of the pilotflame by ionisation flow (all gases exceptHydrogen)
UV-Sensor (p. 65):For flame monitoring, combined with flamemonitor or automatic gas burner integrated in control cabinet.If there is a fault in the torch then solenoidvalves block the gas flow.For all as mixtures.
Control Cabinet (p. 68)
Heating insert or row, ring, forked- or spezialtorch. Optionally also as water cooledversion. Page 9-46
Nozzle (p.47-57)
Shaft (page 7)alternativy: handle (page 5, 6)for manual operation
Adjustment valves (p.78)
Flashback arrestors (p. 79)
Hoses(p. 76, 77)
Connections(p. 80)
Pressure regulator and take-up point safety devices. Frommain catalogue Oxy-fuel.
Oxygen orCompressed air
Fuel gas
Solenoidvalves(p. 72)
Gas supply panel (page 69)
8/10/2019 Griflam_gb de Messer-1
4/90
GRIFLAM Heating Technology
CONTENTS
Handles, Shafts, Injectors 5 - 8
Heating Inserts 9 - 28
Forked Torches 29 - 31
Line Heating Torches 32 - 41
Ring Torches 42 - 46
Nozzles 47 - 57
Ignition and Monitoring Equipment 58 - 71
Accessories 72 - 87
Flame hardening 88 - 89
8/10/2019 Griflam_gb de Messer-1
5/90
GRIFLAM Heating TechnologyHandles:Type MINITHERMType STARLET
MINITHERM with hoseSmall, light handle with Oxygen and fuel gas hose3,2 mm, length 3m and connections for Oxygenand 3/8 LH for fuel gas.Part No. 71606111
MINITHERMHandle without hose.With shaped tube, fine adjustment spindles inOxygen and fuel gas valves and threadless,leak-proof hose connections.Length: 120 mm (without couplings)Handle diameter: 16 mm
Weight: 90 gPart No. 71606109
MINITHERMhandle nickel platedPart No. 71651655
MINITHERMhandle with knob for hang inPart No. 71605770Knob as spare partPart No. 71606336
STARLET 1211With hard wearing mono-block valves. Valvehousings and threads made of Brass withvalves at right angles.DIN Connections for Oxygen and 3/8 LH forfuel gas.Part No. 71605327
STARLET 2211With hard wearing mono-block valves. Valvehousings and threads made of Brass withvalves on the side.DIN Connections for Oxygen and 3/8 LH forfuel gas..Part No. 71605325
STARLET 3201With coaxial valves and hose connections6/6 mm. The coaxial valves permit work evenwhere access is difficult.Part No. 24265000
SPARLET 6201With coaxial valves and hose connections4/4 mm. Rocker handle for gas economiserfunction.Part No. 71600200
SPARLET 7201With coaxial valves and hose connections6/6 mm. With Tipping Lever On-Off.Part No. 71601115
MINITHERMwith 3m hose
MINITHERM
STARLET 1211
STARLET 2211
STARLET 3201
SPARLET 6201 or 7201
8/10/2019 Griflam_gb de Messer-1
6/90
GRIFLAM Heating TechnologyHandles:Type STAR, STARLIGHTType SUPERTHERMType AIRTHERM
STAR1210With perpendicular, heavy duty mono-blockvalves.Valve housing and threads made of Brass.Removable, powder coated Aluminium shellhandle.Ergonomic form, based on the anatomy of thehuman hand for comfortable use.Oxygen connection DIN and fuel gas DIN3/8 LH.Part No. 71605323
STAR2210With mono-block valves on the side,otherwise as STAR 1210 (see above).Part No. 71605321STAR 1000Solid handle made of aluminiumPart No. 71605994STARLIGHT 1302Handle for welding, cutting and heating. Useablefor Inserts in all sizes from STARLET toSUPERTHERM with STARLIGHT-Injector.Part No. 71605978
SUPERTHERMHigher operator comfort through low weight and
ergonomic handle shape.Valves at right angles. Valve bodies haveAluminium alloy gas paths, hard coated forcorrosion resistance even against seawater andaggressive environments. Maintenance free mono-block setting valves for Oxygen or compressed airand fuel gas.Connections:Oxygen: Thread: G 3/8,Hose connection:DN 9 mmFuel gas:Thread: G LH,Hose connection:DN 11 mmPart No. 71601818
AIRTHERM 2002For brazing, heating and special applications withunder pressure air injector (Bunsen mixing system)in the nozzle or in the mixing tube.With fuel gas setting valve for sensitive and exactlydosed flame setting.Hose connection: G 3/8 LHPart No. 0463452
AIRTHERM 2000Version as AIRTHERM 2002, but with economiservalve.Part No. 0463450
AIRTHERM 2001 special for roofing specialistswith safety cut-off.Part No. 0463451
STAR 1210
SUPERTHERM
AIRTHERM2002
AIRTHERM 2000 + 2001
STAR 2210
STARLIGHT 1302
STAR 1210
8/10/2019 Griflam_gb de Messer-1
7/90
GRIFLAM Heating TechnologyShafts:Type MINITHERMType STAR and STARLETType SUPERTHERM
Shafts for the maintenance free mechanisedapplication of welding, brazing, heating andspecial applications, forked torches, striptorches, ring torches, ignition torches andspecial torches. All shafts made robustly outof Brass.Valveshaft MINITHERM:Very short and light construction with Shaftclamping behind adjustment valves.Oxygen: DN 3,2 mmFuel gas: DN 3,2 mmShaft clamping diameter: 15 mmClamping length: 8 mmOverall length: 30 mmPart No. 71602852MINITHERM:Oxygen: G - DN 6 mmFuel gas: G 3/8 LH DN 6 mmOverall length: 35 mm.Part No. 71650936
STARLET:Oxygen: G - DN 6 mmFuel gas: G 3/8 LH DN 9 mmShaft clamping diameter: 35 mmClamping length: 20 mm
Overall length: 70 mmPart No. 71651192
STAR:Oxygen: G - DN 6 mmFuel gas: G 3/8 LH DN 9 mmShaft clamping diameter: 30 mmClamping length: 34 mmOverall length: 86,5 mmPart No. 71602113
SUPERTHERM 20:Oxygen: G 3/8 DN 9 mm
Fuel gas: G LH - DN 11 mmShaft clamping diameter: 32 mmClamping length: 54 mmOverall length: 130 mmPart No. 71602190
SUPERTHERM 30:Oxygen: G1/2 - DN 13 mmFuel gas: G 3/4 LH DN 16 mmShaft clamping diameter: 36 mmClamping length: 29 mmOverall length: 132 mmPart No. 71602830
SUPERTHERM 30Oxygen: G1/2 DN 11 mmFuel gas: G1/2LH DN 11 mmPart No. 71650947
MINITHERM
STARLET
STAR
SUPERTHERM 20
SUPERTHERM 30
Valveshaft MINITHERM
8/10/2019 Griflam_gb de Messer-1
8/90
GRIFLAM Heating TechnologyVenturi effect injectors:Type SLType G-VEN
Version:Type SL:With integrated mixing unit on the Bunsen mixingprinciple.Injector body made of Aluminium with integratedbrass injector, mixing tube with adjustable knurledwheel and screw for locking.
Application:Type SL:Suction injector for torch operation of forked, strip,ring or special torches for preheating or postheating when welding, preheating for deepdrawing, drying of various components.
VersionTYPEGas inlet E Connection pipe
G
L [mm] L1 [mm]Part No.
SL G 3/8 82 38 41340202SL G 3/8 98 65 41340196SL 1 G 3/8 1 98 76 41340197
SL 1 G 1 122 115 41340198SL 1 G 1 144 127 41340199SL 2 G1 2 210 171 41340200
TypeConnectio
nG
Fuel gasconnectio
n
Airconnection
Diameter D[mm]
LengthL [mm]
Flow rateQ [m3/h] Part No.
G-VEN 15 3/8 30 75 180 44130234
G-VEN 20 30 75 180 44130235G-VEN 25 1 1 45 97 600 44130230G-VEN 40 1 1 1 48 180 Fan 44130312G-VEN 65 2 2 2 76 180 Fan 44130313
Version:Type G-VEN:For all types of high output, strip and ring torchsystems. The valve injectors are fitted with theunder pressure mixing system.Flow rate Q [m3/h] is achieved with an averagepressure of p= 3 bar.
Application:Type G-VEN:For the use of large strip torches for fuel gas - airmixtures of the type RB-PMY/D (p. 38) and RB-PM/S (p. 39).
Type SL Type G-VEN
L
D G
G
E
L
L1
8/10/2019 Griflam_gb de Messer-1
9/90
Construction: Injector made of Brass (chromed) with O-Ring handle seals. Heating nozzle of Copper, pacified or chemically Nickel plated with forged mouthpiece. With central flame outlet and mixing system (Injector) on the under pressure mixing principle.
Gases: Type AH Acetylene/Oxygen Hydrogen/Oxygen
Gases: Type PMY Propane/Oxygen Methane (Natural gas)/Oxygen MAPP/Oxygen Acetylene/Compressed Air
Dimensions Part numberType/Size Welding
Range[mm]
Overall length L1[mm]
Nozzle length L2[mm]
Copperheating nozzle
pacified
Copperheating nozzle
chemically Ni platedZ-AH 00 up to 0,3 113 71 71600978 71650394Z-AH 0 0,2 - 0,5 123 81 71600979 71650395Z-AH 1 0,5 - 1,0 133 91 71600980 71650396Z-AH 2 1,0 - 2,0 143 101 71600981 71650397Z-AH 3 2,0 - 4,0 153 111 71600982 71650398
Z-PMY 00 - 113 71 71600988 71650401Z-PMY 0 - 123 81 71600989 71650402Z-PMY 1 - 133 91 71600990 71650403
Z-PMY 2 - 143 101 71600991 71650404Z-PMY 3 - 153 111 71600992 71650405
Heating units in different versions, e.g. with other lengths, available on request.
GRIFLAM Heating TechnologyHeating Inserts:Type MINITHERM Z-AHType MINITHERM Z-PMY, A/D
Applications: Brazing Heating Welding (only for gas type Acetylene/ Oxygen)
L1
L2
8/10/2019 Griflam_gb de Messer-1
10/90
Construction:FK-PM 6: MINITHERM-Insert with high flame power and low weight. Made of stainless steel with interchangeable multi flame nozzle. Suited for applications with high back radiation of heat
Application:Glass Industry, Dentist
FK-PMY, FK-AH: Insert made of brass, chromed. Interchangeable multi flame nozzle.
B3-A: Brass mixing tube, screwed on Copper nozzle.
Application: Brazing, Heating, Welding (only B3-A)
Gases: FK-PMY Propane/Oxygen Methane (Natural gas)/Oxygen MAPP/Oxygen
Gases: FK-AH
Acetylene/Oxygen Hydrogen/Oxygen
Gases: B3-A
Acetylene/Oxygen
Heating units in different versions available on request
GRIFLAM Heating TechnologyHeating Inserts:Type MINITHERM FK-PMYType MINITHERM FK-AHType MINITHERM B3-A
Type B3-A
Type FK-PMY 6
Consumtion [Litre(n)/h]Type Oxygenpressure
[bar]Oxygen Propane Methane MAPP
Part No.
FK-PMY Gr. 1 0,5 bis 1,5 210 - 350 56 - 93 131 219 75 125 71650804FK-PMY Gr. 2 0,5 bis 2,0 280 420 75 112 175 263 100 150 71650805FK-PM Gr. 6 2,5 1400 370 880 - 71651639
Acetylene HydrogenFK-AH Gr. 1 0,5 bis 1,5 210 - 350 190 320 580 970 - 71650808FK-AH Gr. 2 0,5 bis 2,0 210 - 420 190 380 580 - 1170 - 71650809
B3-A (L=261mm) 1,0 3,0 215 440 215 440 597 - 1220 - 71605943B3-A (L=311mm) 1,0 3,0 215 440 215 440 597 - 1220 - 71604348
8/10/2019 Griflam_gb de Messer-1
11/90
Construction: Brass injector with O-Ring handle seals Interchangeable, chromed Copper heating nozzle, or Nickel coated steel nozzle (ZD 11,5/2 PMY) with multi flame outlet and mixing system (Injector) on the under pressure mixing principle
Gas types: Propane/Compressed Air Methane (Natural gas)/ Compressed Air MAPP/Compressed air
Heating units in different versions available on request.
GRIFLAM Heating Technology
Heating Inserts:
Type MINITHERM ZD-PMY
Applications: Soft soldering Heating of small parts and thin sheets
ZD 11/4 PMY
ZD 8/2 PMY
ZD 11,5/2 PMY
The values given apply for average flame settings. By changing the air and fuel gas consumption on the setting valves, it ispossible to increase or decrease the heat output. The dimensions of the primary cone change accordingly.The pressures given are excess pressures measured at the torch inlet.
Compressed Air Fuel gas consumption [l/h] Part No. Part No.Type/Size Pressure
[bar]Consumption
[l/h]
Minimumfuel gassupplypressure
Propane Methane MAPP Complete Nozzle
ZD 8/2 PMY 1,0 2,5 55 285 42 77 115-211 62 114 71651600 71602483ZD 11,5/2 PMY 1,0 2,5 55 285 42 77 115-211 62 114 71651601 71650937ZD 11/4 PMY 1,0 3,0 215 440
0,02 bar58 - 119 159-326 86 - 176 71651602 71602484
8/10/2019 Griflam_gb de Messer-1
12/90
GRIFLAM Heating Technology
Heating Inserts:
Type Z-AH
Gas type: Acetylene/Oxygen Hydrogen/ Oxygen
Construction:Slim (1): Brass mixing tube with slim, interchangeable Copper nozzle with forged bore. Clearly visibleweld poll.
Stubby (2): Brass mixing tube with stumpy, interchangeable Copper nozzle with forged bore. For highthermal loading.Nozzles: see page 47
The values given apply for average flame settings. By changing the air and fuel gas consumption on the setting valves, it is possibleto increase or decrease the heat output. The dimensions of the primary cone change accordingly.The ressures iven are excess ressures measured at the torch inlet.
Applications: Welding Brazing
Heating Flame straightening
Z-AH 4 Mouthpiece version stubby
Z-AH 4 Mouthpiece version slim
Consumption [m3/h] InjectorTypeSize
WeldingRange[mm] Oxygen p= 2-3 bar
Acetylene min. 0,5 bar
VersionSTARLIGHT STARLET STAR SUPER-
THERMZ-A 0 0,2 0,5 0,04 - 0,05 1 - 71601600 - -Z-A 1 0,5 1 0,07 - 0,10 1
2--
7160160171601611
-71601621
--
Z-A 2 1 2 0,13-0,18 12
--
7160160271601612
-71601622
--
Z-A 3 2 -4 0,24 - 0,32 12
--
71601603716.01613
-71601623
--
Z-A 3,5 3 - 5 0,40 - 0,53 12
--
7160182071601830
--
--
Z-A 4 4 - 6 0,37 - 0,49 12
--
71601604716.01614
-71601624
--
Z-A 5 6 9 0,63 - 0,83 12
--
7160160571601615
-71601625
--
Z-A 6 9 - 14 1,07 - 1,43 12
--
7160160671601616
-71601626
--
Z-A 7 14 20 1,48 - 1,97 2 71651805 71601837 71601627 -
Z-A 8 20 30 2,14 - 2,84 2 71651806 71601838 71601628 -Z-A 9 30 40 3,12 - 4,15 2 71651807 - 71600863 71602092Z-A 10 ab 40 3,80 - 5,05 2 71651808 - 71600865 71602093
8/10/2019 Griflam_gb de Messer-1
13/90
GRIFLAM Heating TechnologyHeating Inserts:Type Z-AH flexibleMINITHERMSTARLET, STAR
Gas types: Acetylene/Oxygen
Construction: With multi flame outlet and under pressure mixing system (Injector). Sharp edged flame cone through specially formed outlet jets. Flexible soft Copper mixing tube.
Nozzles: see page 48
Applications: Welding in the range from 1 to 9 mm (with additional intermediate sizes of 3 to 5 mm) Brazing and heating in locations with difficult access.
The values given apply for average flame settings. By changing the air and fuel gas consumption on the setting valves, it is possibleto increase or decrease the heat output. The dimensions of the primary cone change accordingly.The pressures given are excess pressures measured at the torch inlet.
Consumption [m3/h] Part No.Type/Size
Weldingrange[mm]
Oxygen at2-3 bar
Acetylene Injector TypeMINITHERM
Injector TypeSTARLET
Injector TypeSTAR
Z-AH 2 flexible 1 2 0,13 0,18 0,13 0,18 71651834 71601702 71601712Z-AH 3 flexible 2 4 0,24 0,32 0,24 0,32 71651835 71601703 71601713
Z-AH 3,5 flexible 3 5 0,40 0,53 0,40 0,53 71601840 -Z-AH 4 flexible 4 6 0,37 0,49 0,37 0,49 71601704 71601714Z-AH 5 flexible 6 - 9 0,63 0,83 0,63 0,83 71601705 71601715
8/10/2019 Griflam_gb de Messer-1
14/90
GRIFLAM Heating TechnologyHeating Inserts:Type Z-A KONSTANTHERMType F-A KONSTANTHERM
Gas types: Acetylene/Oxygen
Construction:With single flame outlet (Z-A) or multi flame outlet (F-A) and under pressure (Injector) mixing principle.
Designed for thermodynamic stability. Angle: 60The inserts are able to retain a constant mixing ratio, even under high thermal loads so they ensure aneutral welding flame.Where normal heating and welding inserts would separate the gases because of the high heat load, andeven backfire, forcing work to be paused, the KONSTANTHERM inserts allow an undisturbed, continuousheating and melting, which is important for high quality welds.
Application: Welding at places where there is high heat
reflection, e. g. in corners, in the inside of pipes,at pipe junctions.
Work where two units are used to heat or weldsimultaneously from both sides.
Welding of austenitic steels. Surface welding (coating) Armouring sensitive, high alloy steels.
Hot welding in charcoal or coke fires. Rail butt welding Heating, bending and straightening work
(e.g. necking of pipes). Preheating, post heating and adding extra
heat when arc welding crack sensitivematerials.
Consumption [m3/h]TypeSize
WeldingRange[mm]
Length L[mm] Oxygen at
2-3 barAcetylene Injector Type Part No.
Z-AH 6 9 14 approx. 375 1,07 1,43 1,07 1,43 STAR 24256600Z-AH 8 20 30 approx. 445 2,14 2,84 2,14 2,84 STAR 24256800Z-AH 10 above 40 approx. 620 4,29 7,11 4,29 7,11 SUPERTHERM 71602094
designF-A 11 angled 60 approx. 610 5,35 7,12 5,35 7,12 SUPERTHERM 71650976
F-A 11 straight approx. 400 5,35 7,12 5,35 7,12 SUPERTHERM 71650978
The values given apply for average flame settings. By changing the air and fuel gas consumption on the setting valves, it is possibleto increase or decrease the heat output. The dimensions of the primary cone change accordingly.The pressures given are excess pressures measured at the torch inlet.
L
8/10/2019 Griflam_gb de Messer-1
15/90
GRIFLAM Heating TechnologyHeating Inserts:Type F-AType FB-A
Gas types: Acetylene/Oxygen
Construction:Type F-A: Brass mixing tube with brazed multi-jet copper heating nozzle and additional protection ring ofheat resistant steel. The protecting ring stops the nozzle contacting the job so there is no nozzle wear andno backfiring.
Type FB-A: Brass mixing tube with interchangeable, low noise multi-jet copper heating nozzle. Theinserts are significantly quieter than conventional heating nozzles with similar outputs. With the correctflame setting, the noise level is under the 85 dB mark.Nozzles: see page 50
Applications:Surface heating for Melting Normalising Forming Flanging and Straightening
Pre and post heating when welding and flame cutting Soldering and brazing Shrinking and stretching Tin plating Burning off, drying
The values given apply for average flame settings. By changing the air and fuel gas consumption on the setting valves, it is possibleto increase or decrease the heat output. The dimensions of the primary cone change accordingly.The pressures given are excess pressures measured at the torch inlet.
STARLET F-AH 4
SUPERTHERM F-AH 9Heating nozzle and mixing tube
STAR FB-AH 9
Consumption [m3/h] InjectorTypeSize Oxygen at 2-3 bar Acetylene STARLIGHT STARLET STAR SUPERTHERMF-A 3 0,24 0,32 0,24 0,32 - 71603443 - -F-A 4 0,63 - 0,83 0,63 - 0,83 - 71601844 - -F-A 6 1,07 - 1,43 1,07 -1,43 - 71601846 - -F-A 8 2,14 - 2,84 2,14 - 2,84 - 71601848 24254800 -
FB-A 5 0,63 - 0,83 0,63 - 0,83 71651809 71651923 71601915 -FB-A 6 1,08 - 1,43 1,07 - 1,43 71651810 71651924 71601916 -FB-A 7 1,48 - 1,97 1,48 - 1,97 71651811 71651925 71600757 -FB-A 8 2,14 - 2,84 2,14 - 2,84 71651812 71651926 71600758 -FB-A 9 3,12 - 4,15 3,12 -4,15 71651813 - 71600759 -FB-A
103,80 - 5,05 3,80 - 5,05 71651814 - 71600772 -
F-A 9 3,12 - 4,15 3,12 - 4,15 - - 71600864 71602090F-A 11 5,35 - 7,12 5,35 - 7,12 - - - 71602091
8/10/2019 Griflam_gb de Messer-1
16/90
GRIFLAM Heating TechnologyHeating Inserts:Type STAR HF-PMYFType STARLIGHT HF-PMY
The values given apply for average flame settings. By changing the air and fuel gas consumption on the setting valves, it is possibleto increase or decrease the heat output. The dimensions of the primary cone change accordingly.The pressures given are excess pressures measured at the torch inlet.
Gas types: Propane/Oxygen Methane (Natural gas)/ Oxygen MAPP/Oxygen GRIESON/Oxygen
Construction:With interchangeable multi-jet nozzles for surfaceheating.Under pressure mixing system (Injector).
Nozzles: see page 54
Applications: Forming of steel and non-ferrous metals, glass and
quartz glass Deburring of lead crystal glass
Melting, heat treatment
Pre and post heating for weldingand flame cutting
Soldering and brazing Tin plating Burning off, drying
L
Type STAR - HF-PMYF 12 HF-PMYF 13 HF-PMYF 14 HF-PMYF 15Length L: [mm] 420 510 720 830Part No. 71605642 71605643 71605644 71605645
Type STARLIGHT - HF-PMYF 12 HF-PMYF 13 HF-PMYF 14 HF-PMYF 15Length L: [mm] 430 580 880 1090Part No. 71651722 71651723 71651724 71651725Pressure of Oxygen [bar] 1,5 5,0 1,5 6,5 2,0 7,0 2,5 8,0Consumption of Oxygenh: [m3/h] 4,912,0 7,723,0 13,235,3 21,254,2Consumption of Propane: [m3/h] 1,3 3,2 2,1 6,1 3,5 9,4 5,7 14,5Consumption of Methane: [m3/h] 3,1 7,5 4,6 14,4 8,3 22,1 13,3 33,9
8/10/2019 Griflam_gb de Messer-1
17/90
STAR F 18 A SUPERTHERM F 28 A SUPERTHERM F 25 A-wPart number 71604599 71604421 71604411
Construction: Brass injector with O-Ring handle seals Brass mixing tube at 45 angle
Heating nozzle with integrated copper mixturedistributor.
Water cooled heating nozzle withintegrated copper mixturedistributor.
Protective contact bar ofheat resistant steel brazedonto the rear
Cooling water in and outlet pipes arecopper with threaded connections G 3/8
Operatingpressure:Oxygen
Acetylene
2,0 4,0 bar0,5 1,0 bar
2,0 4,0 bar0,5 1,0 bar
2,0 4,0 bar0,5 1,0 bar
Consumption:Oxygen
Acetylene3,0 6,0 m3/h3,0 6,0 m3/h
10,0 12,0 m3/h10,0 12,0 m3/h
10,0 12,0 m3/h10,0 12,0 m3/h
Flame picture: Circular areaFlame d: 20 mm 24 mm 24 mmNozzle D: 35 mm 35 mm 35 mm
Length L1: 675 mm 800 mm 700 mmLength L2 : 430 mm 450 mm 450 mmMixing system: Injector under pressure mixing principle
GRIFLAM Heating TechnologyHeating Inserts:Type STARF 18 AType SUPERTHERMF 28 AType SUPERTHERMF 25 A-w
The values given apply for average flame settings. By changing the oxygen and fuel gas consumption on the setting valves, it ispossible to increase or decrease the heat output. The dimensions of the primary cone change accordingly.The pressures given are excess pressures measured at the torch inlet.
Gas types: Acetylene/Oxygen
Construction:See table, Nozzles: brazed, not interchangeable
Applications:
Forming of steel and non-ferrous metals, glass and quartz glass Melting, heat treatment Flanging and straightening Pre and post heating when welding and flame cutting
Tin plating Burning off, drying Shrinking and stretching Soldering and brazing
SUPERTHERM F 28 A
L1
L2
8/10/2019 Griflam_gb de Messer-1
18/90
GRIFLAM Heating TechnologyHeating Inserts:Type Z-PMY, A/DSTARLET, STARSTARLIGHT, SUPERTHERM
Gases:Type Z-PMY, A/D: Propane/Oxygen Methane (Natural gas)/Oxygen MAPP/Oxygen Acetylene/Compressed Air
Construction:With multi flame outlet and under pressure mixing system(Injector).Brass mixing tube with interchangeable, chrome plated Coppernozzle.
Nozzles: see page 51Applications: Spot or linear heating before welding non-ferrous
metals, glass and quartz glass. Forming steel and non-ferrous metals, glass and
quartz glass. Deburring lead crystal Melting, normalising, flanging, straightening
Pre and post heating when welding andflame cutting
Soldering and Brazing Tin plating Burning off, drying
STARLET Z-PMY 8
STAR Z-PM 12
STARLET Z-PMY 2-90
Consumption [m3/h]TypeSize
Oxygen atp = 2,5 bar Propane Methane
(Natural Gas)
Acetyleneonly mixed withCompressed air
Injector-Type Part-No.
Z-PMY 1 0,11 0,03 0,07 0,01 STARLET 71601861Z-PMY 2 0,16 0,04 0,10 0,02 STARLET 71601862
Z-PMY 2-90 0,16 0,04 0,10 0,02 STARLET 71604605
Z-PMY 3 0,28 0,08 0,18 0,03 STARLET 71601863
Z-PMY 3-90 0,28 0,08 0,18 0,03 STARLET 71604606
Z-PMY 4 0,52 0,14 0,33 0,06 STARLET 71601864
Z-PMY 6 1,11 0,30 0,69 0,12 STARLIGHT 71651712
Z-PMY 6 1,11 0,30 0,69 0,12 STARLET 71601866
Z-PMY 6 2,49 0,66 1,56 0,28 STAR 71601926
Z-PMY 8 2,09 0,56 1,31 0,23 STARLIGHT 71651713
Z-PMY 8 2,09 0,56 1,31 0,23 STARLET 71601868
Z-PMY 8 3,89 1,04 2,43 0,43 STAR 71601251
Z-PMY 10 10,80 2,88 6,75 1,20 STARLIGHT 71651714Z-PMY 10 10,80 2,88 6,75 1,20 STAR 71601252
Z-PMY 12 21,16 5,64 13,23 2,35 STARLIGHT 71651715
Z-PMY 12 21,16 5,64 13,23 2,35 STAR 71601253
Z-PMY 14 24,95 6,65 15,59 2,77 STARLIGHT 71651716
Z-PMY 14 24,95 6,65 15,59 2,77 SUPERTHERM 71602104
8/10/2019 Griflam_gb de Messer-1
19/90
GRIFLAM Heating TechnologyHeating Inserts:Type F-PMF, A/DType F-PMY, A/D
Gases: Type F-PMY, A/D: Propane/Oxygen Methane (Natural gas)/Oxygen MAPP/Oxygen Acetylene/Compressed Air
Construction:
Brass mixing tube with interchangeable, chromed, Copper nozzle. With flat flame outlet and injectormixing system on the under pressure principle.Nozzles: see page 53
The values given apply for average flame settings. By changing the air and fuel gas consumption on the setting valves, it is possibleto increase or decrease the heat output. The dimensions of the primary cone change accordingly.The pressures given are excess pressures measured at the torch inlet.
Application: Forming of steel and non-ferrous metals Forming of glass and quartz glass Pre and post heating when welding and
Flame cutting
Soldering and brazing Tin plating Melting, Normalising
Flanging, Straightening Burning off, drying Deburring lead crystal
Gases: Type F-PMF, A/D: Propane/Oxygen Methane/Oxygen GRIESON/Oxygen Acetylene/Compressed air
Type STAR F-PM 8
Type STAR F-PMY 10
Consumption [m3/h]TypeSize
Oxygen atp=2,5 bar Propane Methane
(Natural Gas)
Acetyleneonly by mixing with
Compressed air
Injector Part-No.
F-PMF 4 0,52 0,14 0,33 0,06 STARLET 71601854F-PMF 6 1,40 0,37 0,88 0,16 STARLET 71601856F-PMF 8 2,49 0,66 1,56 0,28 STARLET 71601858F-PMF 10 4,42 1,18 2,76 0,49 STARLET 71601860F-PMY 8 3,89 1,04 2,43 0,43 STARLIGHT 71651717F-PMY 8 3,89 1,04 2,43 0,43 STAR 71601254F-PMY 10 10,80 2,88 6,75 1,20 STARLIGHT 71651718F-PMY 10 10,80 2,88 6,75 1,20 STAR 71601255F-PMY 12 21,16 5,64 13,23 2,35 STARLIGHT 71651719F-PMY 12 21,16 5,64 13,23 2,35 STAR 71601256F-PMY 12 24,95 6,65 15,59 2,77 SUPERTHERM 71602100F-PMY 14 24,95 6,65 15,59 2,77 STARLIGHT 71651720F-PMY 14 24,95 6,65 15,59 2,77 SUPERTHERM 71602101F-PMY 16 24,95 6,65 15,59 2,77 STARLIGHT 71651721F-PMY 16 24,95 6,65 15,59 2,77 SUPERTHERM 71602102
8/10/2019 Griflam_gb de Messer-1
20/90
GRIFLAM Heating TechnologyHeating Inserts:Type ZF-PM/D
Gases: Propane/Compressed Air Methane (Natural gas)/Compressed Air
Construction:Heat insert with multi flame outlet, triple conical stabilisation jets and mixing system on the under
pressure principle .Brass mixing tube with interchangeable Brass/Steel nozzle with chemical Nickel coating.
Nozzles: see page 56
Applications: Heating wide surfaces Pre and post heating when welding and flame cutting Brazing
Consumption [m3/h]Type/Size Injector Type
Length L[mm] Propane Methane Compressed
AirPart No.:
ZF-PM/D 20/2 STAR 250 0,02 0,04 0,03 0,07 0,24 0,56 44140932ZF-PM/D 20/3 STAR 250 0,03 0,05 0,05 0,09 0,40 0,72 44140933ZF-PM/D 20/4 STAR 250 0,09 0,15 0,16 0,28 1,28 2,24 44140934ZF-PM/D 20/5 STAR 250 0,18 0,30 0,33 0,56 2,64 4,48 44140935ZF-PM/D 20/6 STAR 250 0,52 1,05 0,97 1,96 7,76 15,6 44140936ZF-PM/D 15/2,5 STAR 250 0,02 0,04 0,03 0,07 0,24 0,56 44140937ZF-PM/D 24/3,0 STAR 300 0,03 0,05 0,05 0,09 0,40 0,72 44140938ZF-PM/D 25/5,0 STAR 300 0,09 0,15 0,16 0,28 1,28 2,24 44140939ZF-PM/D 30/7,0 STAR 300 0,18 0,30 0,33 0,56 2,64 4,48 44140940ZF-PM/D 50/16,0 SUPERTHERM 700 1,40 2,40 2,60 4,40 20,8 35,2 44140941
The values given apply for average flame settings. By changing the air and fuel gas consumption on the setting valves, it is possibleto increase or decrease the heat output. The dimensions of the primary cone change accordingly.The pressures given are excess pressures measured at the torch inlet.
L
ZF-PM/D 20/2
8/10/2019 Griflam_gb de Messer-1
21/90
GRIFLAM Heating TechnologyHeating Inserts:Type ZL-PM/D
Gases: Propane/Compressed Air Methane (Natural gas)/Compressed Air
Application: Surface heating Pre and post heating when welding and flame cutting Soldering
Consumption [m3/h]TypeSize
InjectorType
Length L[mm] Propane Methane Compressed
AirPart No.:
ZL-PM/D 30/07 STAR 250 0,21 0,45 0,39 0,84 3,1 6,7 44140943ZL-PM/D 35/08 STAR 250 0,26 0,52 0,48 0,97 3,8 7,7 44140944ZL-PM/D 40/10 STAR 250 0,43 0,87 0,80 1,62 6,4 12,9 44140945ZL-PM/D 40/12 SUPERTHERM 250 0,60 1,20 1,12 2,25 8,9 18,0 44140946ZL-PM/D 50/10 SUPERTHERM 500 0,48 0,98 0,90 1,82 7,2 14,5 44140947ZL-PM/D 50/13 SUPERTHERM 500 0,82 1,65 1,54 3,05 12,3 24,4 44140948ZL-PM/D 50/16 SUPERTHERM 500 1,25 2,55 2,34 4,75 18,7 38,0 44140949
ZL-PM/D 50/17 SUPERTHERM 500 1,42 2,85 2,65 5,25 21,2 42,0 44140950
The values given apply for average flame settings. By changing the air and fuel gas consumption on the setting valves, it is possibleto increase or decrease the heat output. The dimensions of the primary cone change accordingly.The pressures given are excess pressures measured at the torch inlet.
Construction:Heating insert with central flame outlet, triple stabilisation jets, with a long, pointed flame and under
pressure mixing principle.Brass mixing tube with interchangeable Brass/Steel, chemically Nickel plated nozzles .
Nozzles: see page 57
L
ZL-PM/D 50/10
8/10/2019 Griflam_gb de Messer-1
22/90
GRIFLAM Heating TechnologyHeating Inserts:Type Z-PM/DType Z-PM/S
Construction:Heating torch with central flame outlet, concentric stabilisation jets
Operates on the under pressure principle or on the Bunsen mixing principle
with injector and handle or with air suction injector and ball valve
Nozzle body of stainless steel with interchangeable, chemically Nickel plated steel nozzles.Nozzles: see page 55
Applications: Surface heating Pre and post heating when welding and flame cutting
Nozzle Dimensions[mm] Shaft
Consumption[m3/h]Size
D L Connection Propane Methane CompressedAir
Part No.
Z-PM/D 50/16,0 50 700 HA 20 1,40 2,40 2,60 4,40 20,8 35,2 44140971Z-PM/D 50/16,0* 50 700 HA 20 1,40 2,40 2,60 4,40 20,8 35,2 44140972Z-PM/D 70/20,0 70 900 HA 20 3,00 5,00 5,60 9,40 44,8 75,2 44140973Z-PM/D 100/30,0 100 1100 HA 40 7,85 13,0 14,00 23,5 112 - 188 44140974
Z-PM/S 50/16,0 50 700 SL 3/4 1,40 2,40 2,60 4,40 44140975Z-PM/S 50/16,0* 50 700 SL 3/4 1,40 2,40 2,60 4,40 44140976Z-PM/S 70/20,0 70 900 SL 1 3,00 5,00 5,60 9,40 44140977Z-PM/S 100/30,0 100 1100 SL 1 1/2 7,85 13,0 14,00 23,5
Inspired Air
44140978* Nozzle made of heat resisting stainless steel
The values given apply for average flame settings. By changing the air and fuel gas consumption on the setting valves, it is possibleto increase or decrease the heat output. The dimensions of the primary cone change accordingly.The pressures given are excess pressures measured at the torch inlet.
Gases: Propane/Compressed Air or sucked air Methane/Compressed Air or sucked air
L
D
8/10/2019 Griflam_gb de Messer-1
23/90
GRIFLAM Heating TechnologyHeating Inserts:
Acetylene / Sucked air
Type AIRTHERM ZS-A
Gases: Acetylene/Sucked air
Construction:With single flame outlet and Bunsen mixing system (air inhalation injector inthe nozzle).Delivery of nozzle, nozzle-adapter, pipe and handle as spare parts for theindividual torch system.
Applications: Soldering and brazing Pre- and post heating when welding and flame cutting Stress relieving of weld seams Bending and shaping Shrinking and drawing
Stretching Preheating of drawing Tin plating Burning off Drying
The values given apply for average flame settings. By changing the air and fual gas consumption on the setting valves, it ispossible to increase or decrease the heat output. The dimensions of the primary cone change accordingly.The pressures given are excess pressures measured at the torch inlet.
NozzleType
pressure ofAcetylene
[bar]
consumption ofAcetylene
[m3/h]
length of nozzle
[mm]
Part No.
ZS-1A 0,5 0,014 72 71602581ZS-2A 0,5 0,028 72 71602582ZS-3A 0,5 0,165 74 71602583
ZS-4A 0,5 0,310 76 71602584ZS-5A 0,8 0,850 79 71602585
Torch pipe length [mm]50 05321250100 05321240200 05321260350 05321270600 05321280750 053212901000 05321300
Nozzle-Adapter 71603146Handle AIRTHERM 0463452
Seal18,5 x 11,5 x 2 71651917
8/10/2019 Griflam_gb de Messer-1
24/90
Type Inner diameter of nozzle pressure ofMethane
consumption ofMethane
Part No.
FS 15 M 15 mm 0,5 1,0 bar 0,24 0,34 m3/h 71651909FS 18 M - Nozzle 18 mm 0,05 0,5 bar 0,10 0,30 m3/h 71605081FS 22 M - Nozzle 22 mm 0,05 0,5 bar 0,30 1,0 m3/h 71650794FS 31 M - Nozzle 31 mm 0,05 0,5 bar 0,80 2,60 m3/h 71650795
Torch pipes for Inserts type FS 18, FS 22, FS 31length Part No. length Part No. Handle AIRTHERM 0463545250 mm 05321250 600 mm 05321280 Seal 18,5x11,5x2 71651917100 mm 05321240 750 mm 05321290
200 mm 05321260 1000 mm 05321300350 mm 05321270
Die angegebenen Werte gelten fr mittlere Flammeneinstellung. Durch Verndern der Luft- und Brenngas-Verbruche,vorgenommen am Einstellventil, kann die Flammenleistung der Wrmeinstze vergrert oder verkleinert werden.Bei den angegebenen Drcken handelt es sich um berdrcke, gemessen am Brennereingang. Verbruche in Norm-Kubikmeter.
Construction:
Type AIRTHERMFS 18 M , FS 22 M, FS 31 M
Multi flame outlet, air inhalation injektor in the nozzle, torch pipe from 50 up to 1000 mm.For using with handle type AIRTHERM. Delivery of handle, nozzle, torch pipe as spare parts for theindividual torch system.
Type AIRTHERM FS 15 M
Multi flame outlet, air inhalation injector in torch pipe (approx. 120 mm without nozzle).For using with the handle type AIRTHERM. Nozzle and pipe in one part.
Applications: Soldering and brazing Pre and post heating when welding and flame cutting
Shrinking and drawing
GRIFLAM Heating TechnologyHeating Inserts:Methane / Sucked air
Type AIRTHERMFS M
Gases: Methane (Natural gas)/Sucked air
Preheating and dishing Tin plating Burning off
FS 18 PM
FS 31 M
FS 15 MTorch pipe 50mm
8/10/2019 Griflam_gb de Messer-1
25/90
Type Inner diameter of nozzle pressure ofPropane
consumption ofPropane
Part No.
FS 12-P 12 mm 1,5 2,0 bar 0,050 0,058 m3/h 71651910FS 14-P 14 mm 1,5 2,0 bar 0,073 0,085 m3/h 71651911FS 17-P 17 mm 1,5 2,0 bar 0,107 0,124 m3/h 71651912FS 20-P 20 mm 1,5 2,0 bar 0,218 0,252 m3/h 71651913
nozzle jetZS 12/1,4-P 12 mm 1,4 mm 1,5 2,0 bar 0,020 0,023 m3/h 71651914ZS 14/3,5-P 14 mm 3,5 mm 1,5 2,0 bar 0,035 0,040 m3/h 71651915ZS 14/6,0-P 14 mm 6,0 mm 1,5 2,0 bar 0,107 0,124 m3/h 71651916
Handle AIRTHERM 0463452
The values given apply for average flame settings. By changing the air and fuel gas consumption on the setting valves, it is possibleto increase or decrease the heat output. The dimensions of the primary cone change accordingly.The pressure given are excess pressures measured at the torch inlet.
Construction:
Type AIRTHERMFS P
Multi flame outlet, air inhalation injektor in the torch pipe, for using with handle type AIRTHERM.
Type AIRTHERMZS P
Single flame outlet, air inhalation injektor in the torch pipe, for using with handle type AIRTHERM.
Applications: Soldering and brazing Pre- and post heating when welding and flame cutting Shrinking and drawing
GRIFLAM Heating TechnologyHeating Inserts:Propane / Sucked air
Type AIRTHERMFS P, ZS P
Gases: Propane/Sucked air
Preheating for drawing Tin plating Burning off
Typ FS
Typ ZS
8/10/2019 Griflam_gb de Messer-1
26/90
Nozzle Inner diameter of nozzl pressure ofPropane
consumption ofPropane
Part No.
FSH-P 30 30 mm 1,5 4,0 bar 0,59 1,04 m3/h 71651918FSH-P 40 40 mm 1,5 4,0 bar 1,04 2,08 m3/h 71651919FSH-P 50 50 mm 1,5 4,0 bar 1,83 3,76 m3/h 71651920FSH-P 60 60 mm 1,5 4,0 bar 2,72 4,85 m3/h 71651921FSH-P 80 80 mm 1,5 4,0 bar 3,22 5,35 m3/h 71651922
lengthTorch pipe 50 mm 05321250Torch pipe 100 mm 05321240Torch pipe 200 mm 05321260Torch pipe 350 mm 05321270Torch pipe 600 mm 05321280Torch pipe 750 mm 05321290Torch pipe 1000 mm 05321300
Handle Type AIRTHERM 0463452Seal 18,5x11,5,2 71651917
The values given apply for average flame settings. By changing the air and fuel gas consumption on the setting valves, it is possibleto increase or decrease the heat output. The dimensions of the primary cone change accordingly.The pressures given are excess pressures measured at the torch inlet.
Construction:
Type AIRTHERMFSH-P
High power nozzles made of stainless steel, torch pipe in several length, handle type AIRTHERM. Airinhaltion injector in nozzle. Delivery of torch parts for the individual torch system. Seal must be fixedbetween nozzle and pipe.
Applications: Soldering and brazing Pre- and post heating when welding and flame cutting Shrinking and drawing
GRIFLAM Heating TechnologyHeating Inserts:Propane / Sucked air
Type AIRTHERMFSH-P
Gases: Propane/Sucked air
Preheating for drawing Tin plating Burning off
8/10/2019 Griflam_gb de Messer-1
27/90
GRIFLAM Heating TechnologyHeating Inserts:Type STAR F-PM 12-wType SUPERTHERMF-PM 14-wType SUPERTHERM F-PM 16-w
Gases: Propane/Oxygen Methane(Natural gas)/Oxygen
Construction: Water cooled (nozzle and mixing tube) and under pressure mixing system (Injector). Copper heating nozzle with integrated gas mix distribution and flame outlet through radial outlet slots
arranged according to the end circle D=22 (26) mm. Brass mixing tube and cooling water mantel inclined at 60. Copper cooling water inlet and outlet
pipes, hose connections: G 3/8. Circular flame outlet
Applications: Heating at locations with high heat reflection Forming of Steel and non-ferrous metals
The values given apply for average flame settings. By changing the air and fuel gas consumption on the setting valves, it is possibleto increase or decrease the heat output. The dimensions of the primary cone change accordingly.The pressures given are excess pressures measured at the torch inlet.
TYPE: STAR F-PM 12-w SUPERTHERMF-PM 14-w
SUPERTHERMF-PM 16-w
Flame outlet diameter 20 mm 22 mm 26 mmOperating datas: Operating
pressure[bar]
Consumption[m3/h]
Operatingpressure
[bar]
Consumption[m3/h]
Operatingpressure
[bar]
Consumption[m3/h]
Oxygen: 2,5 3 21,16 24,16 4,0 9,0 20 40 9,0 12,0 40 50Propane: ca. 1 5,64 6,44 1,0 2,4 5,4 10,7 1,0 2,4 10,7 13,4Methane ca. 1 13,23 15,1 1,0 2,0 12,5 19,4 1,3 2,5 25,0 31,3Cooling water: ca. 4 ca. 0,04 ca. 4 ca. 0,04 ca. 4 ca. 0,04Length [mm]: 480 615 625
Part No.: 71652288 71600785 71601212
8/10/2019 Griflam_gb de Messer-1
28/90
GRIFLAM Heating TechnologyHeating Insert:Type SUPERTHERM FG 20(without nozzle)
approx. 920 mm
Gases: with nozzles FG-PMY, FGZ-PMY Propane/Oxygen Methane (Natural gas)/Oxygen MAPP/Oxygen GRIESON/Oxygen
Gases: with nozzles FG-AH, FGZ-AH Acetylene/Oxygen Hydrogen/Oxygen
Construction:High powered torch with separate feed for fuel gas and Oxygen through two tubes one above the other.Thus high back-fire resistance. The mixing of fuel gas and Oxygen only occurs in the heating nozzle,immediately before the exit. Tubes and nozzle holder made of Stainless Steel.Brass injector. Nozzle holder with jet to adjust the nozzle with threaded pin. (see also under nozzle typeFG, FGZ, page 52).
Applications:
Forming of steel and non-ferrous metals, glass and quartz glass Deburring lead crystal Melting, stress relieving Flanging, straightening Pre and post heating when welding and flame cutting Soldering and brazing Tin plating Burning off, drying, etc. Nozzles see page 52
Consumption:see nozzles types FG and FGZ, page 52
Part No.: 71602125
8/10/2019 Griflam_gb de Messer-1
29/90
Gases: Type FK-AH Acetylene/Oxygen Hydrogen/Oxygen
Gases: Type FK-PMYF Propane/Oxygen Methane (Natural gas)/Oxygen MAPP/Oxygen GRIESON/Oxygen
Construction:One piece chromed Brass injector with O-Ring handle seals. Mixing tube with brazed, Stainless Steeldistributor and two flexible copper torch pipes. Brazed nozzle connection threaded brass bush and twointerchangeable Copper heating nozzles with flat shaped flame outlet.
Oxygen Fuel gas Acetylene HydrogenType/Size Pressure
[bar]Consumption
[l/h]Pressure
[bar]Consumption
[l/h]Consumption
[l/h]Part No.
FK-AH 1 2,0 4,0 420 - 700 >0,5 382 - 636 1170 - 1795 71650820FK-AH 2 3,0 5,0 550 - 840 >0,5 500 - 734 1528 - 2039 71650821
Fuel gasPressure
[bar]
Propane[l/h]
Methane[l/h]
MAPP
[l/h]GRIESON
[l/h]
FK-PMYF 1 2,0 4,0 420 - 700 >0,5 112 - 187 263-483 150-250 233 389 71650828
FK-PMYF 2 3,0 5,0 550 840 >0,5 147 224 344-525 196-300 306 - 467 71650829
Dimensions:Torch pipe diameter.: 6 mmNozzle gap: 30-35 mmTorch length: 210 mmTorch pipe length: 100 mmWeight: 130 g
Main areas of application: Pipelines and heat exchangers Installation and site work Final assembly of domestic goods Making water and gas manifolds
Production lines and assembly belts Glass shops
Application:MINITHERM forked torch inserts with flat area flame outlet are suitable for large area heating andbrazing of steel and non-ferrous piping and for heating metal, glass and ceramic components.
GRIFLAM Heating TechnologyForked Torches:Type MINITHERM FK-AHType MINITHERM FK-PMYF
The values given apply for average flame settings. By changing the Oxygen and fuel gas consumption on the setting valves, it ispossible to increase or decrease the heat output of the insert.The pressures given are excess pressures measured at the torch inlet.
D
L2
L1
8/10/2019 Griflam_gb de Messer-1
30/90
Gases: Type Z-AH Acetylene/Oxygen Hydrogen/Oxygen
Gases: Type Z-PMYF Propane/Oxygen Methane (Natural gas) /Oxygen MAPP/Oxygen GRIESON/Oxygen
Construction:With single flame outlet and under pressure mixing/injector principle.One-piece, Brass injector (chromed) with O-Ring handle seals. Mixing tube with brazed, stainless steeldistributor and two flexible Copper burner pipes with forged mouthpieces. Forked torches in differentversions on request.
Oxygen Fuel gas Acetylene HydrogenType/Size Pressure
[bar]Consumption
[l/h]Pressure
[bar]Consumption
[l/h]Consumption
[l/h]Part No.
Z AH 00 0,5 2,0 26 - 65 >0,5 26 - 65 72 - 181 71650463Z AH 0 0,5 2,0 56 140 > 0,5 51 127 156 389 71650464Z AH 1 0,5 2,5 120 300 >0,5 109 273 333 833 71650465Z AH 2 1,0 3,0 310 570 >0,5 282 518 861 1583 71602560Z AH 3 2,0 5,5 430 880 >0,5 391 - 800 1194 - 2444 71650466
OxygenType/Size Pressure
[bar]Consumption
[l/h]
Fuel gasPressure
[bar]
Propane[l/h]
Methane[l/h]
MAPP
[l/h]GRIESON
[l/h] Part No.
Z PMYF 00 0,5 2,0 26 - 65 >0,5 7 - 17 16 41 9 - 22 14 - 34 71650468Z PMYF 0 0,5 2,0 56 140 > 0,5 15 37 35 88 19 47 29 74 71650469Z PMYF 1 0,5 2,0 120 300 >0,5 32 80 75 188 40 100 63 - 158 71650470Z PMYF 2 1,0 3,0 310 570 >0,5 83 152 194 - 356 103-190 103 - 300 71650471
Z PMYF 3 1,0 5,5 430 880 >0,5 115 - 235 269 - 550 143-293 226 - 463 71650472
Applications: Making pipeline and heat exchangers Assembly and Installation work Domestic goods final assembly
Production lines and assembly belts Glass shops Water and Gas manifold manufacture
GRIFLAM Heating TechnologyForked Torches:Type MINITHERM Z AHType MINITHERM Z PMYF
The values given apply for average flame settings. By changing the Oxygen and fuel gas consumption on the setting valves, it ispossible to increase or decrease the heat output of the insert.The pressures given are excess pressures measured at the torch inlet.
D
L1
L2
Dimensions:Torch pipe diameter, d: 6 mmNozzle gap D: 30-35 mmTorch length L1: 210 mmTorch pipe length L2: 100 mmWeight: 90 g
8/10/2019 Griflam_gb de Messer-1
31/90
Consumption [m3/h]with 2,5 bar Oxygen pressureType / Size
D [mm](flexible) Flame outlet
Oxygen Propane Methane Acetylene
Part No.
Z - PM 1 30 60 single 0,523 0,139 0,327 - 71650756Z - PM 2 30 60 single 1,106 0,295 0,663 - 71650757Z - PM 3 30 60 single 1,399 0,373 0,874 - 71650758Z - A 2 30 - 60 single 0,276 - - 0,251 71650762Z - A 3 30 60 single 0,730 - - 0,664 71650763Z - A 4 30 60 single 1,248 - - 1,135 71650764Z - A 5 30 60 single 2,488 - - 2,26 71650765
F - PM 1 30 60 multi 1,106 0,295 0,691 - 71650759F - PM 2 30 60 multi 2,091 0,558 1,307 - 71650760F - PM 3 30 60 multi 2,488 0,663 1,555 - 71650761F - A 1 30 60 multi 0,432 - - 0,393 71650766F - A 2 30 60 multi 0,730 - - 0,664 71650767F - A 3 30 60 multi 1,248 - - 1,135 71650768F - A 4 30 60 multi 1,728 - - 1,571 71650769F - A 5 30 60 multi 2,488 - - 2,262 71650770
GRIFLAM Heating TechnologyForked Torches:Type STARLET Z-PM, Z-AType STARLET F-PM, F-A
Gases: Z-PM, F-PM Propane/Oxygen Methane (Natural gas) /Oxygen
The values given apply for average flame settings. By changing the Oxygen and fuel gas consumption on the setting valves, it ispossible to increase or decrease the heat output of the insert.The pressures given are excess pressures measured at the torch inlet.
ca. 250
D
Construction:With single (Z) or laminar heating (F) flame outlet and under pressure mixing system/injector. With two
interchangeable Copper burner pipes. Brass distributor and mixing tube. Equipped with interchangeable smallCopper heating nozzle, type Z-A with brased nozzles - not interchangeable.
Applications:
Heating and brazing of steel and non-ferrous pipes and heating of metal, glass and ceramic components
Gases: Z-A, F-A Acetylene/Oxygen
in the construction of pipelinesand heat exchangers
for installation and assembly work
in the final assembly of domestic goods for production lines and assembly belts
8/10/2019 Griflam_gb de Messer-1
32/90
Gases: Acetylene/Oxygen
Construction:Type T-A: Single row of drilled jets, Copper line heater with screwed stainless steel wear plate,
without water cooling.
Type T-A-w: with water cooling, cooling water connection G 1/4
Applications:
Rust removal Descaling Paint removal Brazing
Forming Normalising Stress relieving Hardening Flame alignment, etc.
without water cooling: to 500 C with water cooling: > 500 C
Flamewidth[mm]
Fuel gasConsumpn.
[m3/h]
OxygenConsumpn.
[m3/h]at p = 2,5 bar
Torchlength
A[mm]
InjectorType
Part No.withoutwater
cooling
Cooling waterconsumption
[l/min]
Part No.with
water cooling
25 0,393 0,432 480 STARLET 71610081 12 71610088
50 0,664 0,730 503 STAR 71600520 12 71610089
100 1,571 1,728 523 STAR 71600521 16 71610090
150 2,262 2,488 533 STAR 71600522 16 71610091
200 4,315 4,746 1300 SUPERTHERM 71602105 16 71610092
250 6,085 6,693 1300 SUPERTHERM 71602106 16 71610093
GRIFLAM Heating TechnologyLine Heating Torches:Type T-AType T-A-w
The values given apply for average flame settings. By changing the Oxygen and fuel gas consumption on the setting valves, it ispossible to increase or decrease the heat output of the insert.The pressures given are excess pressures measured at the torch inlet.
A
8/10/2019 Griflam_gb de Messer-1
33/90
Gases: Propane/Oxygen Methane (Natural gas) /Oxygen MAPP/Ox en
Construction:
Copper line heating torch with three offset rows of jets and screwed stainless steel wear plate, integrated mixturedistribution, with (G connection) or without water cooling.
Applications: Forming, stress relieving, normalising, Brazing, Hardening Rust removal, Descaling, Paint removal
Without water cooling: to 500 C With water cooling: > 500 C
Flamewidth[mm]
Fuel gasFuel gas
Consumpn.[m3/h]
OxygenConsumpn.
[m3/h]at p=2,5 bar
Torchlength
A[mm]
InjectorType
Part No.withoutwater
cooling
Coolingwater
consumption[l/min]
Part No.with
watercooling
Propane 0,333
Methane 0,78025 MAPP 0,416 1,248 380 STARLET 71610148 12 71610155
Propane 0,663Methane 1,55550MAPP 0,829
2,488 402 STAR 71600523 12 71610156
Propane 1,037Methane 2,429100MAPP 1,296
3,887 432 STAR 71600524 16 71610157
Propane 2,879Methane 6,749150MAPP 3,599
10,798 547 STAR 71600525 16 71610158
Propane 7,139Methane 16,732200MAPP 8,924
26,771 643 SUPER-THERM
71602107 16 71610159
Propane 7,139Methane 16,732250MAPP 8,924
27,771 663 SUPER-THERM
71602108 16 71610160
GRIFLAM Heating TechnologyLine Heating Torches:Type T-PMYType T-PMY-w
The values given apply for average flame settings. By changing the Oxygen and fuel gas consumption on the setting valves, it ispossible to increase or decrease the heat output of the insert.The pressures given are excess pressures measured at the torch inlet.
A
8/10/2019 Griflam_gb de Messer-1
34/90
Gases: Propane/Oxygen
Methane/Oxygen
Construction:
Drilled torch head with 5, 7 or more rows of jets. Water cooled torch head and water colled mixing tube.High power injektor type SUPERTHERM B.Width of torch head: 125 mm, 150 mm, 200 mm, 250 mm or on request.Mixing tubes straighten or angled.
Applications: fast heating to high temperatures deforming, melting, fusing, hardening
Type Width
[mm] Fuel gas
* Consumption of
fuel gas[m3/h]
* Consumption of
Oxygen[m3/h] at 2-4 bar Injector
Propane 4,64 7,73T-PM 125/7-wMethane 10,88 18,13
17,4 29,0 B 150
T-H 125/7-w125
Hydrogen 30,56 50,0 11,0 18,0 B 132Propane 8,19 13,71T-PM 150/7-wMethane 19,19 32,13
30,70 51,40 B 165
T-H 150/7-w150
Hydrogen 30,56 50,0 11,0 18,0 B150Propane 4,64 7,73T-PM 200/5-wMethane 10,88 18,13
17,4 29,0 B150
T-H 200/5-w200
Hydrogen 30,56 50,0 11,0 18,0 B 132Propane 8,19 13,71T-PM 250/5-wMethane 19,19 32,13
30,70 51,40 B 165
T-H 250/5-w250
Hydrogen 48,33 80,56 17,4 29,0 B150
Delivery only to customer specific request* Consumption in dependence of Injector and quantity of jets
GRIFLAM Heating Technology
High power Line heating torch
water cooled
The values given apply for average flame settings. By changing the Oxygen and Fual gas consumption on the setting valves, it ispossible to increase or decrease the heaut output of the torch.The pressures given are excess pressures measured at the torch inlet.
Gases: Hydrogen/Oxygen
8/10/2019 Griflam_gb de Messer-1
35/90
GRIFLAM Heating TechnologyLine Heating Torches:Type T-PMY/D
Gases: Propane/Compressed Air Methane (Natural gas)/Compressed Air MAPP/Compressed Air
Construction:Line heating torch with single row of jets and lateral flame stabilisation, with integrated distribution of gasmixture, without water cooling.
Line heating torches with differnt flame width or other types of injectors available on request.
Applications: Heating and Brazing, Processing of Plastics, etc.
Type/Size Flame width[mm]
Fuel gasFuel gas
Consumption[m3/h]
AirConsumption
(at 2,5 bar)[m3/h]
Injector-Type Part No.
Propane 0,06 1,1Methane 0,14 1,1T-PMY/D-40-1 40MAPP 0,07 1,1
STARLET 71651657
Propane 0,13 2,5Methane 0,31 2,5T-PMY/D-90-1 90MAPP 0,17 2,5
STARLET 71650781
Propane 0,17 3,2Methane 0,40 3,2T-PMY/D-150-1 150MAPP 0,21 3,2
STAR 71650782
Propane 0,20 3,9Methane 0,49 3,9T-PMY/D-200-1 200MAPP 0,26 3,9
STAR 71650783
Propane 0,26 4,9Methane 0,61 4,9T-PMY/D-250-1 250MAPP 0,33 4,9
STAR 71651658
Propane 0,31 5,9Methane 0,74 5,9T-PMY/D-300-1 300
MAPP
0,39 5,9
STAR 71651659
The values given apply for average flame settings. By changing the Air and fuel gas consumption on the setting valves, it is possibleto increase or decrease the heat output of the insert.The pressures given are excess pressures measured at the torch inlet.
370
8/10/2019 Griflam_gb de Messer-1
36/90
GRIFLAM Heating TechnologyLine Heating Torches:Type TF-PMY/D
Gases: Propane/Compressed Air Methane (Natural gas)/Compressed Air MAPP/Compressed Air
Construction:Line heating torch with flat flame outlet through Stainless Steel Ribbon packages.Up to 300 mm Flame width as standard type, up to 700 mm Flame width are available on request.
Applications: Soft soldering Processing of Plastics
Type/Size Flame widthL [mm]
Fuel gasFuel gas
Consumtion[m3/h]
AirConsumtion(at 1-4 bar)
[m3/h]
Injector-Type Part-No.
Propane 0,22 - 0,54 4,2 - 10,3Methane 0,53 - 1,29 4,2 - 10,3TF-PMY/D-50 50MAPP 0,28 - 0,69 4,2 - 10,3
STAR 71651644
Propane 0,34 - 0,85 6,5 - 16,2
Methane 0,81 - 2,03 6,5 - 16,2TF-PMY/D-100 100MAPP 0,43 - 1,08 6,5 - 16,2
STAR 71651645
Propane 0,44 - 1,08 8,4 - 20,6Methane 1,05 - 2,58 8,4 - 20,6TF-PMY/D-150 150MAPP 0,56 - 1,37 8,4 - 20,6
STAR 71651646
Propane 0,67 - 1,67 12,8 - 31,7Methane 1,60 - 3,96 12,8 - 31,7TF-PMY/D-200 200MAPP 0,85 - 2,11 12,8 - 31,7
STAR 71651647
Propane 0,79 - 1,97 15,1 - 37,4Methane 1,89 - 4,68 15,1 - 37,4TF-PMY/D-250 250MAPP 1,01 - 2,49 15,1 - 37,4
SUPERTHERM 71651648
Propane 1,03 - 2,53 19,5 - 48,0Methane 2,44 - 6,00 19,5 - 48,0TF-PMY/D-300 300MAPP 1,30 - 3,20 19,5 - 48,0
SUPERTHERM 71651649
The values given apply for average flame settings. By changing the Air and fuel gas consumption on the setting valves, it is possibleto increase or decrease the heat output of the insert.The pressures given are excess pressures measured at the torch inlet.
370
45 35
L
8/10/2019 Griflam_gb de Messer-1
37/90
Construction:Line heating torch with interchangeable Copper heating nozzles and under pressure mixingsystem. Torch body of seamless drawn steel tube, chemically Nickel plated. Brass injector.
Line heating torches for other lengths, nozzle sizes, etc. available on request.Nozzles: see page 49
Applications:Laminar heating for Straightening Forming Normalising
Gases: Type RBF-A Acetylene/Oxygen
Consumption [m3/h]Type/Size L[mm]
B[mm]
T[mm]
H[mm]
TypeOxygen Acetylene
PartNo.
RBF-A-200 400 200 20 40 STAR 0,95 0,95 44140961RBF-A-400 600 400 20 40 STAR 1,78 1,78 44140962RBF-A-600 800 600 20 40 STAR 2,65 2,65 44140963RBF-A-800 1200 800 20 40 SUPERTHERM 3,48 3,48 44140964RBF-A-1000 1400 1000 20 40 SUPERTHERM 4,33 4,33 44140965
Consumption [m3/h]Type L[mm]
B[mm]
T[mm]
H[mm]
TypeOxygen Propane Methane MAPP
PartNo.
RBF-PMY-200 400 200 20 40 STAR 0,95 0,25 0,59 0,32 54140961RBF-PMY-400 600 400 20 40 STAR 1,78 0,47 1,11 0,59 54140962RBF-PMY-600 800 600 20 40 STAR 2,65 0,71 1,66 0,88 54140963RBF-PMY-800 1200 800 20 40 SUPERTHERM 3,48 0,93 2,18 1,16 54140964
RBF-PMY-1000 1400 1000 20 40 SUPERTHERM 4,33 1,15 2,71 1,44 54140965
GRIFLAM Heating TechnologyLine Heating Torches:Type RBF-AType RBF-PMY
The values given apply for average flame settings. By changing the Oxygen and fuel gas consumption on the setting valves, it ispossible to increase or decrease the heat output of the insert.The pressures given are excess pressures measured at the torch inlet.
L
B
T
H
Gases: Type RBF-PMY
Propane/Oxygen Methane (Natural gas) /Oxygen MAPP/Oxygen
Pre and post heating when welding and flame cutting Stress relieving weld seams Bending and forming
8/10/2019 Griflam_gb de Messer-1
38/90
Construction:Line heating torch, single sided with interchangeable steel nozzles and under pressure mixing system.Body is seamless steel tube, painted black. Brass mixing tube.
Nozzles: see page 55 (Z-PM/D 24/3,0)
Line torches for other lengths, nozzle sizes, and with laminar nozzle outlet are available on request.
Applications:Laminar heating for Straightening, forming, normalising Pre and post heating when welding and flame cutting Stress relieving of weld seams, bending and forming
Gases: Propane/Compressed air Methane (Natural gas)/Compressed air MAPP/Compressed air
Consumption [m /h]Type/Size L[mm]
B[mm]
T[mm]
H[mm]
TypePropane Methane
Part No.
RB-PMY/D-200 500 200 25 56 STAR 0,36 0,63 44140966RB-PMY/D-400 700 400 25 56 STAR 0,68 1,19 44140967RB-PMY/D-600 900 600 25 56 STAR 1,00 1,75 44140968RB-PMY/D-800 1300 800 25 56 SUPERTHERM 1,32 2,31 44140969RB-PMY/D-1000 1500 1000 25 56 SUPERTHERM 1,64 2,87 44140970
GRIFLAM Heating TechnologyLine Heating Torches:Type RB-PMY/D
The values given apply for average flame settings. By changing the compressed air and fuel gas consumption on the setting valves,it is possible to increase or decrease the heat output of the insert.The pressures given are excess pressures measured at the torch inlet.
H
T
B
L
8/10/2019 Griflam_gb de Messer-1
39/90
Construction:Line heating torch with two different torch power shapes in three or five rows.Handle of seamless steel tube, painted black with atmospheric injector and ball valve.
Strip heating torches in other lengths, other versions or for compressed air available on request.
Applications:Laminar heating for Straightening Pre and post heating when welding and cutting
Gases: Propane/Sucked air Methane (Natural gas)/Sucked air
Consumption[m3/h]
Type A[mm]
Gas-pressure[mbar]
E[mm]
L[mm]
H[mm]
ConnectionG
Propane Methane
PartNo.
RB-PM/S-5 500 20 50 50 700 55 G 3/8 0,265 0,717 44171478RB-PM/S-5 1000 20 50 50 1200 55 G 3/8 0,531 1,433 44171479RB-PM/S-5 1500 20 50 50 1700 55 G 3/8 0,797 2,150 44171480RB-PM/S-5 2000 20 50 50 2200 55 G 1,065 2,866 44171481RB-PM/S-5 500 200 500 50 700 55 G 3/8 0,265 0,358 44171482RB-PM/S-5 1000 200 500 50 1200 55 G 3/8 0,531 0,717 44171483RB-PM/S-5 1500 200 500 50 1700 55 G 3/8 0,797 1,075 44171484RB-PM/S-5 2000 200 500 50 2200 55 G 1,065 1,433 44171485
GRIFLAM Heating TechnologyLine Heating Torches:Type RB-PM/S
The values given apply for average flame settings. By changing the fuel gas consumption on the setting valves, it is possible toincrease or decrease the heat output of the insert.The pressures given are excess pressures measured at the torch inlet.
G
L
E
A
H
8/10/2019 Griflam_gb de Messer-1
40/90
GRIFLAM Heating TechnologyLine Heating Torches:Type RBS-PMY/DModular SystemWith interchangeable nozzles
Gases: Propane/Comressed air Methane (Natural gas)/Comressed air MAPP/Compresed air
Construction:GRIFLAM line heating torches in themodular system with interchangeablenozzles can be used in lengths up to 6000mm. The torches can be assembled both
as straight versions and, with the swivellink, set up for angled or cylindrical bodiesor mounted onto them.As standard, the torches are equippedwith heating nozzles type Z-PM/D-24/3,0(page 55), however they can be fitted withother nozzles. The line heating torchesare mainly used with Methane (Naturalgas) or Propane in combination withatmospheric or compressed air.
Blind flange:Part No.: 41070079
Swivel link: Part No.: 43820501
Torch head:
Type No. ofnozzles
Part No.
RBS-PMY/D-250-1 5 43820940RBS-PMY/D-500-1 10 43820941RBS-PMY/D-1000-1 20 43820942RBS-PMY/D-250-2 9 43820943RBS-PMY/D-500-2 19 43820944RBS-PMY/D-1000-2 39 43820945
Connecting pipe with flange:
Length = 700 mm
Connection Thread Part No.G 22/S 22 M 20x1 43820933
HA 20 G 43820934HA 40 G 1 43820935HA 80 G 1 43820936SL G AG 43820937SL 1 G 1 AG 43820956
SL 1 G 1 - AG 43820938SL 2 G 2 - AG 43820939
Accessories:Hexagonal bolt with nut and screw, 44240040Flange seal, 44410307Heating nozzle Z-PM/D 24/3,0, 40142012
Blind flange
Swivel link
Torch head
Connecting pipe + flange
8/10/2019 Griflam_gb de Messer-1
41/90
Gases: Propane/Oxygen Methane (Natural gas) /Oxygen
Construction:Made of heat resistant stainless steel with integrated gas mixture distribution and ball cone connectionthreads G (external thread).
Applications:
Heating metallic materials Heating of glass and quartz glass Flame polishing Deburring lead crystal glass Drawing of quartz tubes Hardening
GRIFLAM Heating TechnologyLine Heating Head:Type T-PM
Type T-PM 26/1 with 1 row of jets Flame width: 26 mm Part number: 71604214
Type T-PM 80/1 with 1 row of jets Flame width: 80 mm Part number: 71604215
Type T-PM 26/2 with 2 offset rows of jets Flame width: 26 mm
Part number: 71602586
Type T-PM 80/2 with 2 offset rows of jets Flame width: 80 mm
Part number: 71604216
Type T-PM 26/3 with 3 offset rows of jets Flame width: 26 mm Part number: 71602587
Type T-PM 80/3 with 3 offset rows of jets Flame width: 80 mm Part number: 71602968
Torch heads made of stainless steel in other widthor with more jets on request.
T-PM 26 T-PM 80
Example of application:Line heating torch head T-PM 26 with 45-angle to mixing tube,Heating insert type STARLET
45
26 80
8/10/2019 Griflam_gb de Messer-1
42/90
GRIFLAM Heating TechnologyRing Torches:Type MINITHERM C
Gases: Type C2-A, C3-A Acetylene/Oxygen
Construction:Small ring torch with threading gap (b) for the heating of pipes. Copper tube torch ring and mixing tube, chemicallyNickel plated. Injector type MINITHERM.
Applications:For brazing and heating in the fields of: Piping and heat exchanger construction Installation and commissioning work
Type/Size. Inner diameter di[mm]
Entry opening b[mm]
Number ofJets
Length L[mm]
Part No.
C2-A-36-3 36 30 3 171 71650915C2-A-36-5 36 30 5 171 71650916
C2-PMYF-36-5 36 30 5 171 71650917C3-A-55-7 55 30 7 191 71650918
C3-PMYF-55-7 55 30 7 191 71650919C3-A-75-7 75 45 7 215 71650920
C3-PMYF-75-7 75 45 7 215 71650921
C3-A-90-8 90 55 8 227 71650922C3-PMYF-90-8 90 55 8 227 71650923
Gases: Type C2-PMYF, C3-PMYF Propane/Oxygen Methane (Natural gas) /Oxygen MAPP/Oxygen GRIESON/Oxygen
Consumption [l/h] at an Oxygen pressure of p = 2,5 barMediumC2-A-36-3 C2-A-36-5 C3-A-55-7 C3-A-75-7 C3-A-90-8
Oxygen 305 305 485 485 485Acetylene 277 277 441 441 441
Consumption [l/h] at an Oxygen pressure of p = 2,5 barMedium
C2-PMYF-36-5 C3-PMYF-55-7 C3-PMYF-75-7 C3-PMYF-90-8Oxygen 305 485 485 485Propane 81 129 129 129Methane 191 303 303 303MAPP 102 162 162 162
GRIESON 161 255 255 255
Final assembly of domestic goods Production lines and assembly belts Glass processing Making water and gas manifolds
The values given apply for average flame settings. By changing the Oxygen and fuel gas consumption on the setting valves, it ispossible to increase or decrease the heat output of the insert.The pressures given are excess pressures measured at the torch inlet.
L
di
b
8/10/2019 Griflam_gb de Messer-1
43/90
GRIFLAM Heating TechnologyRing Torches:Type RG1 g-A/D, PMYType RK1 g-A/D, PMY
Gases: Type A/D Acetylene/Compressed Air
Applications: Pre and post heating when welding Annealing of weld seams Soldering and brazing Bending and forming
The values given apply for average flame settings. By changing the Oxygen or air and fuel gas consumption on the setting valves, itis possible to increase or decrease the heat output of the insert.The pressures given are excess pressures measured at the torch inlet.
Construction:Single row drilled (folding) ring torch made from seamless drawn chemically Nickel plated steel pipe withdouble mixture feed and additional distribution ring above 400 mm pipe diameter, without water cooling,for pipes up to 600 mm outer diameter (d).Ring torches for different pipe diameters, with two and three rows of jets or with different injector types onrequest.
Shrinking and drawing Preheating for swaging Processing glass and quartz glass
Pipe diameter d [mm]Consumption[m3/h] 50 100 150 200 300 400
Compressed Air 0,7 1,5 1,1 2,3 1,25 2,8 1,4 3,2 1,7 3,7 1,9 4,1Acetylene 0,09 0,19 0,14 0,29 0,16 0,35 0,18 0,40 0,21 0,46 0,24 0,51
Oxygen 0,9 5,5 1,4 8,6 1,7 10,2 2,0 11,7 2,3 13,7 2,6 15,3Propane 0,2 1,5 0,4 2,4 0,5 2,85 0,6 3,3 0,6 3,8 0,7 4,3Oxygen 0,9 3,4 1,4 5,3 1,7 6,3 1,9 7,2 2,2 8,5 2,5 9,4Methane 0,6 2,1 0,9 3,3 1,05 3,9 1,2 4,5 1,4 5,3 1,5 5,9Oxygen 1,3 7,4 2,0 11,6 2,4 13,7 2,7 15,8 3,2 18,5 3,5 20,6MAPP 0,6 3,2 0,9 5,0 1,05 5,95 1,2 6,9 1,4 8,0 1,5 9,0
SizeL [mm] 460 525 700 820 980 1400D [mm] 120 170 220 275 395 600
Injector type STAR STAR STAR STAR STAR SUPERTHERMPart No.
Closed 71610350 71610352 71650793 71610354 71610356 71610358Folding 71610494 71610495 71650775 71610496 71610497 71610498
Gases: Type PMY Propane/Oxygen Methane (Natural gas) /Oxygen MAPP/Oxygen
L
D
d
8/10/2019 Griflam_gb de Messer-1
44/90
Gases: Acetylene/Oxygen
Applications: Pre and post heating when welding Annealing weld seams Soldering and brazing
Construction:(Folding) ring torch made of seamless drawn steel pipe, chemically Nickel plated, with interchangeableCopper nozzles type FK-A Gr. 0, 1, 2, or 3 and laminar (F) flame outlet. Double gas mixture feed and
additional distribution pipe from pipe diameter 400mm, without water cooling, for pipes up to 600mm outerdiameter. (Folding) ring torches for different pipe diameters, with two rows of nozzles or water coolingavailable on request.Nozzles: see page 49
DimensionsPipe d
[mm]
Fuel gasConsumpti
on[m3/h]
O2 -Consumpti
on.[m3/h]
L[mm]
D[mm]
NozzleTypeSize
InjectorType
Part No.ClosedVersion
Part No.FoldingVersion
50 1,3 1,8 1,3 1,8 560 220 FK-A 1 STAR 71610389 71610508100 2,1 2,8 2,1 2,8 680 270 FK-A 1 STAR 71610391 71610509
200 3,5 4,6 3,5 4,6 920 370 FK-A 1 STAR 71610393 71610510
300 4,8 6,4 4,8 6,4 1200 470 FK-A 1 STAR 71610395 71610511
400 6,4 8,5 6,4 8,5 1600 670 FK-A 1 SUPERTHERM 71610397 71610512
500 7,8 10,3 7,8 10,3 1850 770 FK-A 1 SUPERTHERM 71610399 71610513
600 9,1 12,1 9,1 12,1 2000 870 FK-A 1 SUPERTHERM 71610400 71610514
GRIFLAM Heating TechnologyRing Torches:Type RGF-AType RKF-A
The values given apply for average flame settings. By changing the Oxygen and fuel gas consumption on the setting valves, it ispossible to increase or decrease the heat output of the insert.The pressures given are excess pressures measured at the torch inlet.
Bending and Forming Shrinking and drawing Preheating for swaging Processing glass and quartz glass
L
D
d
8/10/2019 Griflam_gb de Messer-1
45/90
Gases: Acetylene/Oxygen
Applications: Pre and post heating when welding Annealing of weld seams Solderin and brazin
Construction:(Folding) ring torch made of seamless drawn chemically Nickel plated steel tube, with interchangeablecopper heating nozzles type ZK-A Gr. 0, 1, 2, or 3 and central (Z) flame outlet.
Double mixture feed and additional distribution pipe above pipe diameter 400mm, without water cooling,for pipes up to 600mm external diameter. (Folding) ring torches for other pipe diameters, with 2 two rowsof nozzles, other nozzle sizes, different types of gas or water cooled versions available on request.Nozzles: see page 49
DimensionsPipe d[mm]
Fuel gasConsumption
[m3/h]
O2Consumption
[m3/h]
L[mm]
D[mm]
NozzleTypeSize
InjectorType
Part No.ClosedVersion
Part No.FoldingVersion
50 0,7 1,0 0,7 1,0 560 220 ZK-A 1 STAR 71610363 71610501
100 1,2 1,5 1,2 1,5 680 270 ZK-A 1 STAR 71610365 71610502
200 1,9 2,5 1,9 2,5 920 370 ZK-A 1 STAR 71610367 71610503
300 2,6 3,5 2,6 3,5 1200 470 ZK-A 1 STAR 71610369 71610504
400 3,5 4,6 3,5 4,6 1600 670 ZK-A 1 SUPERTHERM 71610371 71610505
500 4,2 5,6 4,2 5,6 1850 770 ZK-A 1 SUPERTHERM 71610373 71610506
600 4,9 6,5 4,9 6,5 2000 870 ZK-A 1 SUPERTHERM 71610374 71610507
GRIFLAM Heating TechnologyRing Torches:Type RGZ-AType RKZ-A
The values given apply for average flame settings. By changing the Oxygen and fuel gas consumption on the setting valves, it ispossible to increase or decrease the heat output of the insert.The pressures given are excess pressures measured at the torch inlet.
Shrinking and drawing Preheating for swaging Bending and forming Processing glass and quartz glass
L
D
d
8/10/2019 Griflam_gb de Messer-1
46/90
Gases: Propane/Compressed Air Methane /(Natural gas) /Compressed Air MAPP/Compressed Air
Applications:Ring shaped heating for
Straightening, forming, annealing Pre and post heating when welding and flame cutting
Consumption [m3/h]Pipe d
[mm]
L[mm]
D[mm] Injector Propane Methane Air
Part No.Closed
Version
Part No.Folding
Version25 575 225 STAR 0,50 0,90 7,50 42010025 4401002550 600 250 STAR 0,60 1,12 9,00 42010050 4401005075 660 275 STAR 0,75 1,40 11,25 42010075 44010075100 720 300 STAR 1,00 1,87 15,00 42010100 44010100125 780 325 STAR 1,12 2,10 16,80 42010125 44010125150 840 350 STAR 1,25 2,35 18,75 42010150 44010150200 960 400 STAR 1,50 2,80 22,50 42010200 44010200250 1100 450 SUPERTHERM 1,75 3,30 26,25 42010250 44010250300 1240 500 SUPERTHERM 2,00 3,75 30,00 42010300 44010300350 1290 550 SUPERTHERM 2,25 4,20 33,75 42010350 44010350400 1640 620 SUPERTHERM 2,50 4,70 37,50 42010400 44010400450 1690 670 SUPERTHERM 2,75 5,20 41,25 42010450 44010450500 1890 720 SUPERTHERM 3,00 5,60 45,00 42010500 44010500600 2040 820 SUPERTHERM 3,50 6,60 52,50 42010600 44010600
GRIFLAM Heating TechnologyRing Torches:Type RGZ-PMY/DType RKZ-PMY/D
The values given apply for medium flame settings. By changing the consumption of compressed air and fuel gas at the settingvalves, the flame power of the heating insert can be increased or decreased.The pressures given are excess pressures, measured at the torch inlet.
Construction:
(Folding) ring torch made of seamless drawn, chemically Nickel plated or black lacquered steel tube,brass injector and folding device.Ring torches for other dimensions on request.Nozzles: Type Z-PM/D 24/3,0 see page 55
Bending and forming Annealing weld seams
L
dD
8/10/2019 Griflam_gb de Messer-1
47/90
GRIFLAM Heating TechnologyHeating Nozzles:Type Z-A
Gases: Acetylene/Oxygen
Construction:
Single jet copper welding and heating nozzle with central flame outlet.Sharply defined primary cone through special processing of the nozzle jets and proven flow technology incanal outlets.Heating nozzles with other threads, special surface coating, water cooling or from heat resisting stainless steelavailable on request.
Applications:Used with under pressure mixing systems (injectors) individually or combined for welding, melting,brazing, heating, flame straightening etc.
Nozzle dimensions[mm]
fit for Insert typeType/Size Type
Weldingrange[mm] D L SW
ThreadsM
[mm] STARLET STAR
NozzlePart No.
(1) 11 40 9 M 8 71601600 - 71601540Z-A 0
(2)
0,2 0,5
13 45 11 M 10x1,5 - - 24234910(1) 11 40 9 M 8 71601601 - 71601541Z-A 1
(2)
0,5 - 1
13 45 11 M 10x1,5 71601611 71601621 24234110
(1) 11 40 9 M 8 71601602 - 71601542Z-A 2
(2)
1 -2
13 45 11 M 10x1,5 71601612 71601622 24234210
(1) 11 40 9 M 8 71601603 - 71601543Z-A 3
(2)
2 - 4
13 50 11 M 10x1,5 71601613 71601623 24234310
(1) 11 40 9 M 8 71601820 - 71601882Z-A 3,5
(2)
3 - 5
13 50 11 M 10x1,5 71601830 - 71600686
(1) 11 40 9 M 8 71601604 - 71601544Z-A 4
(2)
4 - 6
13 50 11 M 10x1,5 71601614 71601624 24234410
(1) 11 56 9 M 8 71601605 - 71601545Z-A 5
(2)
6 - 9
16 65 14 M 12x1,5 71601615 71601625 24234510(1) 11 56 9 M 8 71601606 - 71601546Z-A 6
(2)
9 -14
16 65 14 M 12x1,5 71601616 71601626 24234610
Z-A 7 (2) 14 20 19 80 17 M 14x1,5 71601837 71601627 24234710Z-A 8 (2) 20 30 19 80 17 M 14x1,5 71601838 71601628 24234810Z-A 9 (2) 30 40 22 100 22 M 18x1,5 - 71600863 71600170Z-A 10 (2) from 40 22 100 22 M 18x1,5 - 71600865 71600171
Type Z-A slim (1): Low weight Good weld pool visibility
Type Z-A stubby (2): For high thermal loads
L
D
Type Z4-A stubby
Type Z4-A slim
SW
8/10/2019 Griflam_gb de Messer-1
48/90
GRIFLAM Heating TechnologyHeating Nozzles:Type Z-A flexible
Gases: Acetylene/Oxygen
Construction:Single jet copper heating and welding nozzle with central flame outlet. Complete with flexible coppermixing tune and brass threaded connection nipple.
Single jet copper welding and heating nozzle with central flame outlet.Sharply defined primary cone through special processing of the nozzle jets and proven flow technology incanal outlets. Heating nozzles with other threads, special surface coating, water cooling or from heatresisting stainless steel available on request.
Applications:Used with under pressure mixing systems (injectors) individually or combined for welding, melting,brazing, heating etc..Especially suitable for welding in tight locations (out of position) or for even heating when brazing with several heatingnozzles arranged in forks.
L2
Nozzle dimensions [mm]
TypeDia.
D Ltotalstraight
L2Spanner
sizeSW
fit for InsertInjector-Type Nozzle
Part No.
10 71651834 MINITHERM 7165183610 71601702 STARLET 71601742Z-A 2-b11 71601712 STAR 7160175210 71651835 MINITHERM 7165183710 71601703 STARLET 71601743Z-A 3-b11 71601713 STAR 71601753
Z-A 3,5-b
197
10 71601840 STARLET 7160046110 71601704 STARLET 71601744Z-A 4-b
11 71601714 STAR 71601754222
23
10 71601705 STARLET 71601745Z-A 5-b
7,9
224 25 11 71601715 STAR 71601755
8/10/2019 Griflam_gb de Messer-1
49/90
GRIFLAM Heating TechnologyHeating Nozzles:Type ZK-A and FK-AType ZK-PMY, A/D und FK-PMY, A/D
Gases: Type ZK-A, FK-A: Acetylene/Oxygen
Construction:
Small, copper heating nozzle for use as interchangeable nozzle for fork, line heating, segment, ring orspecial torches.Type ZK-A, ZK-PMY:Single jet heating nozzle with central flame outlet and sharply defined, pointed primary cone.Type FK-A, FK-PMY:Multi-jet heating nozzle with laminar flame outlet from concentric exit jets.Heating nozzles with different connection threads, special coatings, water cooling or from heat resistingstainless steel available on request.Type FSB-A/D:Small nozzle made of chromed copper with a circle of flame outlet slits.
Gases: Type ZK-PMY A/D, FK-PMY, A/D: Propane/Oxygen Methane/Oxygen MAPP/Oxygen Acet lene/Com ressed Air
Nozzle dimensions [mm] Oxygen consumption with fuel gas: [m3/h]Type/Size D d L SW M Acetylene
Part No.
ZK-A 0 6 - 20 11 M9x1 0,03-0,09 71603000ZK-A 1 6 - 20 11 M9x1 0,04-0,13 71603001ZK-A 2 6 - 20 11 M9x1 0,07-0,35 71603002ZK-A 3 6 - 20 11 M9x1 0,13-0,65 71603003FK-A 0 9 5,5 20 11 M9x1 0,04-0,14 71603005FK-A 1 9 5,5 20 11 M9x1 0,06-0,21 71603006FK-A 2 9 5,5 20 11 M9x1 0,08-0,31 71603007FK-A 3 9 5,5 20 11 M9x1 0,10-0,41 71603008
Nozzle dimensions [mm]Oxygen consumption with fuel
gas: [m3/h]Oxygen
consumption withfuel gas: [m3/h]
Type/Size
D d L SW M Propane Methane MAPP Acetylene
Part No.
ZK-PMY, A/D 0 6 - 20 11 M9x1 0,01-0,05 0,01-0,03 0,01-0,05 0,01-0,03 71603010ZK-PMY, A/D 1 6 - 20 11 M9x1 0,02-0,07 0,01-0,04 0,02-0,07 0,02-0,04 71603011
ZK-PMY, A/D 2 6 - 20 11 M9x1 0,03-0,10 0,02-0,06 0,03-0,10 0,03-0,07 71603012ZK-PMY, A/D 3 6 - 20 11 M9x1 0,04-0,15 0,03-0,09 0,04-0,15 0,04-0,09 71603013FK-PMY, A/D 0 9 5,5 20 11 M9x1 0,06-0,24 0,05-0,13 0,06-0,24 0,06-0,14 71603015FK-PMY, A/D 1 9 5,5 20 11 M9x1 0,10-0,37 0,08-0,20 0,10-0,37 0,10-0,22 71603016FK-PMY, A/D 2 9 5,5 20 11 M9x1 0,16-0,59 0,13-0,33 0,16-0,59 0,16-0,36 71603017FK-PMY, A/D 3 9 5,5 20 11 M9x1 0,20-0,72 0,15-0,40 0,20-0,72 0,20-0,43 71603018
FSB-A/D - - 17 10 M10x1 Acetylene: 0,04 m3/h, Compr. air (1,5 bar): 0,22 m3/h
L
SW
D M
Typ FK 1-PMY, A/D
d
L
FSB-A/D
Gases: Type FSB-A/D Acetylene/Compressed air
8/10/2019 Griflam_gb de Messer-1
50/90
GRIFLAMHeating TechnologyHeating Nozzles:Type F-AType FB-AH
Gases: Acetylene/Oxygen
Construction:Multi-jet heating nozzle with laminar flame outlet.Type STARLET/STAR
F-A 4, 6 and 8: Made of chromed Copper with 1 ring of flame outlet jets.Type STAR/ SUPERTHERMF-A 9 and 11:Made of chromed Copper with 1 ring of flame outlet jets and additional wear ring of heatresisting steel.Type STAR FB-A 5-10: Low noise, multi-jet, chromed copper heating nozzle with 2 rings of flame outletjets and additional centre jet from size Gr. 8.
Melting, Annealing Forming
Applications:Used with under pressure mixing system (injectors) individually or combined for:
Soldering and Brazing Shrinking, stretching etc.
L D
STAR FB-A 8 dSW
Nozzle dimensionsExternalThreadType/Size Injector
type Diameter[mm]
Length[mm]
Spannersize [mm]
D d L SW
M/M[mm]/[]
fit for InsertNozzle
Part No.
F-A 3 6 3 40 9 71603443 71602080F-A 4 7 5 50 9 71601844 24114460F-A 6 9 6 50 9 71601846 24247610F-A 8
STARLET
12,5 8 80 17
M8
71601848 71600455F-A 8 12,5 8 80 17 M14x1,5 24254800 24213811F-A 9 STAR 24 9 103 - with 14
mixing tube71600864 71600422
F-A 9 24 9 103 - 71602090 71600422F-A 11
SUPERTHERM 30 9 103 -
with 14mixing tube 71602091 71600423
FB-A 5 22 12 47 14 716.01915/.51809/.51923 71600725FB-A 6 22 13 47 14
M12x1,5716.01916/.51810/.51924 71600726
FB-A 7 25 15 54 17 716.01757/.51811/.51925 71600727FB-A 8 25 16 54 17
M14x1,5716.01758/.51812/.51926 71600728
FB-A 9 28 18 61,5 19 716.01759/.51813/.51927 71600779FB-A 10
STAR
28 20 61,5 19M18x1,5
716.01772/.51814/.51928 71600780
8/10/2019 Griflam_gb de Messer-1
51/90
GRIFLAM Heating TechnologyHeating Nozzles:Type Z-PMY, A/D
Applications:Used with under pressure mixing system (injector) individually or combined for melting, annealing,forming, soldering, brazing, shrinking and stretching etc..Heating nozzles with different connection threads, Nickel plated, water cooled or from heat resistingstainless steel available on request.
Construction:
With stabilised, single flame outlet.Type STARLET Z-PMY, A/D 1-8as two piece heating nozzle comprising inner nozzle with central jet and radial brass flame stabilisationslits and interchangeable copper heating cap.Type STAR and SUPERTHERM Z-PMY, A/D 6-14as two piece heating nozzle comprising inner nozzle with central jet and radial brass flame stabilisationslits and interchangeable copper heating cap.
Gases: Type Z-PMY, A/D: Propane/Oxygen Methane (Natural gas) /Oxygen MAPP/Oxygen Acetylene/Compressed Air
L
D M
SW
Nozzle dimensions [mm]
TypeSize
DiameterD
LengthL
SpannersizeSW
Conn.threads
Mfit for Insert
NozzlePart No.
Z-PMY 1 STARLET 71601861 71600590Z-PMY 2 STARLET 71601862 71600591Z-PMY 3
5STARLET 71601863 71600592
Z-PMY 4 STARLET 71601864 71600593Z-PMY 6 STARLET 71601866 71600594Z-PMY 8
6
50,6 12 M8x1
STARLET 71601868 71600595Z-PMY 6 13 57 M12x1,5 STAR / STARLIGHT 71601926 / 71651712 71601233Z-PMY 8 14 62 STAR / STARLIGHT 71601251 / 71651713 71601234Z-PMY 10 15 67 STAR / STARLIGHT 71601252 / 71651714 71601235Z-PMY 12 16,5 72
19 M14x1,5STAR / STARLIGHT 71601253 / 71651715 71601236
Z-PMY 12 16,5 78 SUPERTHERM 71602103 71601240Z-PMY 14 17,5 83
22 M18x1,5SUPERTHERM / STARLIGHT 71602104 / 71651716 71601241
8/10/2019 Griflam_gb de Messer-1
52/90
GRIFLAM Heating TechnologyHeating Nozzles:Type FG-PMY and FGZ-PMYType FG-A and FGZ-A
Construction:
Copper, gas mixing, high power nozzles with wide area flame outlet shape. Fuel gas and Oxygen are fedseparately to the nozzle and mixed internally by a number of separate mixers (Injectors) using the underpressure mixing principle. By dividing the total mixture volume into part volumes and through the shortlengths of the gas feed canals, the nozzles can withstand very high thermal loads and are practicallyabsolutely back-fire proof.
Type FG-PMY and FG-A:With two concentrically arranged circles of flame outlet jets.
Type FGZ-PMY and FGZ-A:With two concentrically arranged circles of flame outlet jets and central pilot flame oulet.
Gases: Type FG-PMY and FGZ-PMY: Propane/Oxygen Methane (Natural gas) /Oxygen Mapp/Oxygen
Gases: Type FG-A and FGZ-A: Acetylene/Oxygen
Nozzle dimensions[mm]
Operating pressure[bar]
Consumption [m3/h]Type/Sizeforgas D d L Oxygen Fuel gas Oxygen Fuel gas
Part No.
Propane/OxygenFG 20/21 PMY 27 20,5 50 2,0 5,0 0,3 1,0 20,0 42,7 5,1 11,0 71602081
FGZ 20/21 PMY 27 20,5 50 2,0 5,0 0,3 1,0 20,0 42,7 5,1 11,0 71603127Methane/Oxygen
FG 20/21 PMY 27 20,5 50 1,0 4,0 0,2 1,0 12,9 35,3 8,0 22,0 71602081FGZ 20/21 PMY 27 20,5 50 1,0 4,0 0,2 1,0 12,9 35,3 8,0 22,0 71603127
Mapp/OxygenFG 20/21 PMY 27 20,5 50 2,0 5,0 0,3 1,0 20,0 42,7 6,7 14,2 71602081
FGZ 20/21 PMY 27 20,5 50 2,0 5,0 0,3 1,0 20,0 42,7 6,7 14,2 71603127
Acetylene/OxygenFG 20/12 A 27 22 50 2,0 4,0 0,3 1,0 4,2 7,0 3,8 6,4 71600765
FGZ 20/12 A 27 22 50 2,0 4,0 0,3 1,0 4,2 7,0 3,8 6,4 71603125FG 20/15 A 27 22 50 2,0 4,5 0,5 1,0 7,9 14,7 7,2 13,4 71600967
FGZ 20/15 A 27 22 50 2,0 4,5 0,5 1,0 7,9 14,7 7,2 13,4 71603126
dL
D
8/10/2019 Griflam_gb de Messer-1
53/90
GRIFLAM Heating TechnologyHeating Nozzles:Type F-PMF, A/DType F-PMY, A/D
Gases: Type F-PMY, A/D: Propane/Oxygen Methane (Natural gas)/Oxygen MAPP/Oxygen Acetylene/Compressed Air
Construction:All nozzles with wide surface flame shape, Consumptionsee heating inserts pag
Top Related