2

Make-up

Losses within the system are mostly unavoidable. To ensure a smooth operation refilling from

time to time is necessary.

heat resp.cool generator

symbolic illustration

V

12

PY5 P1

PM1PL1u Q1

M

10

1

11

MAG

”pressure controlled” operation

membraneexpansion vessel

load

multicontrolautofill solo -SMCAstorage tank -GMCA

13

heat resp.cool generator

2

3

symbolic illustration

V

PY5 P1

PM1PL1u Q1

M

10

1

11

12

”contact controlled” operation

load

multicontrolautofill solo -SMCAstorage tank -GMCA

13

1

multicontrolpressure maintenance

possible supply of multiplepressure maintenance devices

OPERATING PRINCIPLE

Operating principle

Legend

1 ... make-up pipe 11 ... optional circulation pipe2 ... expansion overflow pipe (from system return) 12 ... vessel overflow3 ... expansion pressure pipe (to system return) 13 ... connection for mediumOPTIONAL10 ... suction pipe recirculation collecting pipe

M1 ... make-up pump 1u ... vessel pressure transmitter bottomPLY5 ... switch mixer P1 ... system pressure transmitterQ1 ... water counter

Page 3: WE SAY: MCA REFILL PLEASE! · MCA-S1-2.7 MCA-S1-5.2 MCA-G640 MCA-G1000 nominal content litre 640 1000 max. operating pressure unit ( )PN bar max. upper working pressure bar 2,7 5,2

3

OPERATING PRINCIPLE

Especially in air conditions, cold water systems, solar systems etc. a special medium mixture is

used whereby a simple refill of fresh water is not possible. Multicontrol autofill solo -S forMCA

automatic, amount controlled make-up of special media offers the possibility to refill a certain

amount media mixture out of a storage tank is required.

We recommend our multicontrol -G vessels as storage tanks, but they don‘t have to beMCA

used compulsively. On site already existing vessels can possibly be used as storage tanks,

because the needed vessel connection unit is always included in scope of delivery of the

control unit multicontrol autofill -S. With it the necessary level measurement in theMCA

storage tank as well as a permanent temperature measurement in the stored medium is

realised.

It is distinguished between the following operating modes:

� ”contact controlled” operation:

Thereby control of the -S for example is carried out by a multicotrol pressureMCA

maintenance device. If the level within the pressure less expansion vessel falls below a certain

minimum level an electric contact will request make-up. The make-up pump (M1) supplies

ready mixed system medium out of the storage tank (e.g. -G) to the expansion vessel asMCA

long as it is refilled up to a preset level.

On demand there is the possibility to supply several multicontrol pressure maintenance

devices with make-up medium by one multicontrol autofil device. Thereto a make-up module

is installed in every supplying pressure maintenance device and via a contact each of these

devices can request make-up from the -S.MCA

� ”pressure controlled” operation:

Pressure controlled make-up takes place into the closed system directly. The system pressure

is hold constant by a membrane expansion vessel ( ), nevertheless it can fall by possibleMAG

leaks. Assumed that the proper function of the is given, make-up can be necessary.MAG

Therefore the vessel pressure transmitter (P1) registers the actual pressure in the system and

compares it with the adjusted set point. Decreases the pressure below the set value the make-

up pump (M1) starts. It pumps medium from the storage tank directly into the system. As soon

as the set pressure is reached, the make-up pump (M1) stops.

The make-up amout is recorded by a water meter (Q1) and compared with the maximum

adjusted make-up amount. Is this amount exceeded the make-up stops and the make-up

operation is locked. Only after verification and disengaging by the system support engineers,

make-up can be activated again. Beside the amount controlled operating mode also a time

controlled operating mode is available, which is advantageous in case of known and regular

necessary make-up amounts.

Page 4: WE SAY: MCA REFILL PLEASE! · MCA-S1-2.7 MCA-S1-5.2 MCA-G640 MCA-G1000 nominal content litre 640 1000 max. operating pressure unit ( )PN bar max. upper working pressure bar 2,7 5,2

4

OPERATING PRINCIPLE DETAILS/

Within the storage tank ( -G) a vessel pressure transmitter (Pl1u) for level measurement isMCA

arranged. Level measurement bases on pressure measurement of the medium in the storage

tank. Out of it the filling height (=vessel level) is determined (also not by weight measurement

of load cells at the vessel).

By undercutting a certain minimum vessel level make-up stops to protect the make-up pump

(M1) from running dry. Not before the storage tank ( -G) is filled again further make-up canMCA

take place.

The storage tank is operated as open vessel to avoid negative pressure or overpressure. All

connections are mounted on site, which implicates high flexibility because connection

positions at the storage tank can be adapted to local conditions.

Circulation function

A circulation function is also included and after proper piping to the storage tank it can be

activated in the settings. It offers the possibility to mix longer stored medium to antagonise

settling out different media components at the storage tank bottom.

Therefore in the working hydraulics an electromotive activated switch mixer (Y5) is built in

already. To start the circulation functon it is activated by the electronic control, either in

periodic intervals of directly before any make-up for an adjustment time, depending on the

requirements of our costumer. For this purpose the switch mixer (Y5) is carried out as three way

mixing valve that is adjusted in position ”make-up” by default and moves to position

”circulating” during the circulation process. Thereupon the make-up pump (M1) is activated

and circulates the medium via the switch mixer (Y5) from the tank connection unit back to the

storage tank. Though all parts of the medium are well mixed again and afterwards make-up

can take place.

Medium recirculation

For safety of financial reasons it can additionally be necessary to prevent a leakage of the

particular system medium (e.g. via safety valves,...) and collect it again. For this purpose at the

storage tank -G a connection for a collecting pipe for media recirculation is provided.MCA

Page 5: WE SAY: MCA REFILL PLEASE! · MCA-S1-2.7 MCA-S1-5.2 MCA-G640 MCA-G1000 nominal content litre 640 1000 max. operating pressure unit ( )PN bar max. upper working pressure bar 2,7 5,2

5

D TAILE S

operator panel with four lines,illuminated plain text display

easily accessible cableglands, on requestmountable to the left side

enclosed electronic unit,optimally protected

always included four potentialfree contacts:- fault- warning- make-up in operation- device operation enabled

on-site connections, on requestconvertible (right or left side)

corrosion resistance: base andpiping made of stainless steel,brass/red brassmounting holes in the base

plate for fixing the device

transportable palletfor easy insertion

tank overflow incl.discharge hopper

tank emptying for anymaintenance

storage tank made ofhigh medium resistantsynthetic material

Details

torsion resistant lattice-workmade of zinc-plated steel tube

continuoustemperaturecontrol

connection forcirculation pipeconnection for medium

recirculation from systemsafety valve(s)

Page 6: WE SAY: MCA REFILL PLEASE! · MCA-S1-2.7 MCA-S1-5.2 MCA-G640 MCA-G1000 nominal content litre 640 1000 max. operating pressure unit ( )PN bar max. upper working pressure bar 2,7 5,2

6

ACCESSORY

Accessory

Your great benefit:� From pioneer to number one: 45 years

experience in pressure maintenance

� Company owned costumer service for

technical service of your system throughout

the product‘s life

� Convenient complete solution for make-up

of special media from an external tank with

connection for a collecting pipe for medium

recirculation to the tank

� Special low-noise, self priming make-up

pump

make-up / degassing

multicontrol autofill vessel -GMCA

expansion modules / remote signalling

multicontrol expansion module

”analog signalling”

multicontrol expansion module

”binary signalling”

multicontrol expansion module

”binary signalling & remote reset”

multicontrol moduleSMS

multicontrol bus modules

connection accessory

multicontrol autofill connection set G

multicontrol autofill connection set _MC

general accessory

multicontrol metal housing

multicontrol contact temperature sensor

incl. strap (diameter 15-40mm)

multicontrol temperature sensor

cable 10m, incl. immersion sleeve G1/2", 10PN

collecting pan, 3 spacer

discharge hopper 50 with siphon

Further products of our multicontrol series:

� expansion and pressure maintenance device picocontrol kompakt PCK

� expansion and pressure maintenance device multicontrol kompakt MCK

� pressure maintenance device multicontrol modular MCM

� pressure maintenance device topcontrol modular TCM

� pressure maintenance device multicontrol cool MCC

For detailled information compare brochure ”multicontrol original accessory”.

Page 7: WE SAY: MCA REFILL PLEASE! · MCA-S1-2.7 MCA-S1-5.2 MCA-G640 MCA-G1000 nominal content litre 640 1000 max. operating pressure unit ( )PN bar max. upper working pressure bar 2,7 5,2

7

1

10 11

1

TECHNICAL DATA

Positions 10, 11, 12, 13 on the storage tank -GMCAare adapted to local conditions on site!

MCA-S1-2.7 MCA-S1-5.2 MCA-G640 MCA-G1000

nominal content litre 640 1000

max. operating pressure unit ( )PN bar

max. upper working pressure bar 2,7 5,2

max. operating pressure vessel ( )PN bar

max. temp. at connection point °C

insertion tilted dimension mm 1005 1145

voltage V/Hz

max. electrical power kW 0,6 0,8

fuse protection A

dimensions A mm

B mm 800 1000

C mm 1005 1145

D mm

E mm

F mm

G mm

weight kg 49,5 52 50 63

connections 1 "

10 "

11 "

12"

13" - R 1

1 … make-up pipe 10 … suction pipe 11 … optional circulation pipe 12 … vessel overflow

13 … optional connection for medium recirculation collecting pipe

Technical changes reserved!

Rp 1 R 1

Rp 1 R 1

- Geberit 50DN

445 -

1150 -

Rp 3/4 -

830

470 -

405 -

10 -

150 1200

225

70

1220

230/50 -

-

10 -

-

- 0

type elko-mat eder multicontrol autofill

multicontrol autofill MCA storage tank -GMCA

-

Technical data

Page 8: WE SAY: MCA REFILL PLEASE! · MCA-S1-2.7 MCA-S1-5.2 MCA-G640 MCA-G1000 nominal content litre 640 1000 max. operating pressure unit ( )PN bar max. upper working pressure bar 2,7 5,2

8

www.eder-heizung.at

BETTER HEATING. SAFE BET.

plant complexity(generating capacity,

static height,total content,

working pressure)

elko-mat eder controlpico PCK

elko-flex eder

elko-mat eder multicontrol MCK

elko-mat eder multicontrol MCM

elko-mat eder topcontrol TCM

ANTON EDER GMBHA-9909 Leisach 52Tel.: +43 (0) 4852 644 77Fax: +43 (0) 4852 644 77-20

[email protected]:

branch A-5733 Bramberg | Weyerstraße 350 | Tel.: +43 (0) 6566 7366branch A-1230 Vienna | Gorskistraße 15 | Tel.: +43 (0) 1 985 37 30