20
Internal lining Installation guide Villaboard ® lining AUSTRALIA MARCH 2009

Transcript of Villaboard Lining Covers:Villaboard Lining Covers. Fibre Cement… · table 1 table 2 villaboard...

Page 1: Villaboard Lining Covers:Villaboard Lining Covers. Fibre Cement… · table 1 table 2 villaboard lining sheet sizes product length width 900 1200 1350 6mm thickness 1800 2400 2700

Internal lining

Installation guide

Villaboard® lining

AUSTRALIAMARCH 2009

Villaboard Lining Covers:Villaboard Lining Covers 13/3/09 6:04 PM Page 3

Page 2: Villaboard Lining Covers:Villaboard Lining Covers. Fibre Cement… · table 1 table 2 villaboard lining sheet sizes product length width 900 1200 1350 6mm thickness 1800 2400 2700

1 INTRODUCTION

James Hardie Villaboard® lining is a premium sanded fibre cement sheetwith recessed edges for flush jointing. Villaboard lining is an ideal internallining for bathrooms, laundries, kitchens and high traffic abuse areas. It isnot suitable as an external wall cladding.

6mm - Residential applications9mm - Commercial applications12mm - Heavy duty applications

The main features of Villaboard lining are:

� Durable wet area lining sheet.

� Creates suitable surface for tiles, paint or wallpaper.

� Long edges recessed for easy flush-jointing.

� Reliable impact resistant lining. Ideal for wall lining in commercialapplications where walls are prone to damage.

� Suitable for use in fire and acoustically rated systems.

This manual covers the use of Villaboard lining in internal wall and ceilingapplications. Further technical literature relating to Villaboard lining isavailable from James Hardie in the following manuals:

� Eaves and soffits Technical Specification.

� Wet area construction Design Manual.

� Fire and acoustically rated walls technical manuals.

The specifier or other responsible party for the project must ensure theinformation and details in this guide are appropriate for the intendedapplication and that specific design and detailing is undertaken for areaswhich fall outside the scope of this documentation.

Make sure your information is up to dateWhen specifying or installing James Hardie products, ensure you have thecurrent manual. If you’re not sure you do, or you need more information,visit www.jameshardie.com.au or Ask James Hardie™ on 13 11 03.

CONTENTS1 INTRODUCTION 2

2 SAFE WORKING PRACTICES 4Warning 4Recommended safe working practices 4Working instructions 4Hole-forming 5Storage and handling 5Quality 5

3 FRAMING / SUBSTRATE 6General 6Timber 6Steel 6Masonry/concrete/AAC 6Frame tolerances 6Masonry/concrete/AAC tolerances 6Curved walls 6

4 SHEET LAYOUT 7General 7

5 INSTALLATION 7General 7Fasteners 8Fixing to framed walls 8Fixing to framed ceilings 9Fixing to masonry/concrete AAC 10Batten/furring channels 10Autoclaved aerated concrete (AAC) 11

6 JOINTS 12General 12Set joints 12Butt joints 14Internal corners 15External corners 15Control joints 15

7 FINISHES AND MAINTENANCE 16General 16Glancing light 16Level of finishes 16Paint finishes 17Cornices 17Tiled finishes 17Maintenance 17

8 PRODUCT INFORMATION 17General 17Product mass 17Durability 17

9 WARRANTY 19

WE VALUE YOUR FEEDBACKTo continuously improve the development of our products andsystems, we value your input. Please send any suggestions,including your name, contact details, and relevant sketches to:

Ask James Hardie™

Fax 02 9638 [email protected]

Villaboard Lining:Villaboard LiningV2 13/3/09 6:11 PM Page 2

Page 3: Villaboard Lining Covers:Villaboard Lining Covers. Fibre Cement… · table 1 table 2 villaboard lining sheet sizes product length width 900 1200 1350 6mm thickness 1800 2400 2700

TABLE 1

TABLE 2

VILLABOARD LINING SHEET SIZES

PRODUCT LENGTH WIDTH

900 1200 1350

6mm thickness

1800 �

2400 � � �

2700 �

3000 � � �

3600 � �

4200 � �

9mm thickness

2400 �

2700 �

3000 � �

3600 �

12mm thickness

3000 �

Smooth recessed edge fibre cement internal lining sheet for tiledand untiled applications. Recommended applications are:

6mm - Residential applications9mm - Commercial applications12mm - Heavy duty applications

LengthWidth

PRODUCT / ACCESSORIES / TOOLS

COMPONENTS SUPPLIED BY JAMES HARDIE

ACCESSORIES DESCRIPTION ACCESSORIES DESCRIPTION

HardiBlade® saw blade James Hardie base coatØ 185mm poly diamond blade, for fast, clean cutting Water resistant base coat used in the setting of of James Hardie fibre cement. Villaboard joints.

HardiDrive® screw James Hardie top coatFor fastening to 0.8mm - 1.6mm BMT steel frames. Water resistant top coat which is used over JamesLength: 22mm and 32mm Hardie base coat.Quantity: 1000

JH score and snap knife James Hardie joint sealantScoring tool for easy cutting. Paintable polyurethane joint sealant for use in

movement joints.Volume: 300ml

FibreshearElectric cutting tool.

COMPONENTS NOT SUPPLIED BY JAMES HARDIEJames Hardie recommends the following products for use in conjunction with its Villaboard lining. James Hardie does not supply these products and does not provide a warranty for their use. Please contact the component manufacturer for information on their warranties and further information on their products.

ACCESSORIES DESCRIPTION ACCESSORIES DESCRIPTION

Galvanised fibre cement nails Broadknife30mm x 2.8 fibre cement nails. For setting of joints on Villaboard lining.

Buildex FibreZIPS® Second coat trowel 200mmFor fastening 6mm Villaboard lining to 0.55mm to For installing second coats on set joints.0.75mm BMT steel frames. Length: 20mm® denotes a registered mark of Buildex

Buildex FibreZIPS Finishing coat trowelFor fastening 9 and 12mm Villaboard lining to For installing top coats on set joints.0.55mm to 0.75mm BMT steel frames.Length: 30mm

Backing rod Corner toolBacking to sealant in movement joints. For setting of internal corners.

Perforated paper tape HawkJoint reinforcing tape. To assist in the application of finishing compounds

especially with the use of trowels.

Level/straight edge Hand sanderFor checking straightness of frame. For sanding set joints.

Hand guillotine Notched trowelGuillotine for cutting fibre cement. For applying tile adhesive to face of Villaboard lining.

Stud adhesiveFor fastener/adhesive fixing to timber andsteel studs. Must be suitable for fibre cement.

VILLABOARD LINING INSTALLATION MANUAL MARCH 2009 3

Villaboard Lining:Villaboard LiningV2 13/3/09 6:11 PM Page 3

Page 4: Villaboard Lining Covers:Villaboard Lining Covers. Fibre Cement… · table 1 table 2 villaboard lining sheet sizes product length width 900 1200 1350 6mm thickness 1800 2400 2700

4 VILLABOARD LINING INSTALLATION MANUAL MARCH 2009

2 SAFE WORKING PRACTICES

WORKING INSTRUCTIONSRefer to recommended safe working practices before starting any cuttingor machining of product.

Score and SnapScore and snap is a fast and efficient method of cutting James Hardiebuilding products using James Hardie’s special tungsten tipped scoreand snap knife.

Preferably score on the face side of the product. Score against a straightedge and repeat the action to obtain adequate depth for clean break –normally one third of sheet thickness. Snap upwards to achieve break.Smooth any rough edges with a rasp.

Hand guillotineMake guillotine cut on the off-cut side of line to allow for the thickness of

the blade.FibreshearAn electrically powered, fast, clean and effortless way of cutting JamesHardie building products, especially around curves such as archways.Make fibreshear cut on the ‘off-cut’ side of the line to allow for the

thickness of the shear.

WARNING - DO NOT BREATHE DUST AND CUTONLY IN WELL VENTILATED AREAJames Hardie products contain sand, a source of respirable crystallinesilica which is considered by some international authorities to be a causeof cancer from some occupational sources. Breathing excessive amountsof respirable silica dust can also cause a disabling and potentially fatallung disease called silicosis, and has been linked with other diseases.Some studies suggest smoking may increase these risks. Duringinstallation or handling: (1) work in outdoor areas with ample ventilation; (2) minimise dust when cutting by using either ‘score and snap’ knife, fibrecement shears or, where not feasible, use a HardiBlade® saw blade anddust-reducing circular saw attached to a HEPA vacuum; (3) warn others inthe immediate area to avoid breathing dust; (4) wear a properly-fitted,approved dust mask or respirator (e.g. P1 or P2) in accordance withapplicable government regulations and manufacturer instructions to furtherlimit respirable silica exposures. During clean-up, use HEPA vacuums orwet cleanup methods - never dry sweep. For further information, refer toour installation instructions and Material Safety Data Sheets available atwww.jameshardie.com.au. FAILURE TO ADHERE TO OUR WARNINGS,MATERIAL SAFETY DATA SHEETS, AND INSTALLATION INSTRUCTIONSMAY LEAD TO SERIOUS PERSONAL INJURY OR DEATH.

JAMES HARDIE RECOMMENDED SAFE WORKING PRACTICES

CUTTING OUTDOORS1. Position cutting station so wind will blow dust away from the user or

others in working area.2. Use one of the following methods based on the required cutting rate:

Best� Score and snap� Hand guillotine� FibreshearGood� Dust reducing circular saw equipped with HardiBlade® saw blade

and HEPA vacuum extraction.

CUTTING INDOORS� Cut only using score and snap, hand guillotine or fibreshears

(manual, electric or pneumatic).� Position cutting station in a well-ventilated area.

REBATING/SANDING/DRILLING/OTHER MACHININGWhen rebating, sanding, drilling or machining you should always wear a P1or P2 dust mask and warn others in the immediate area.

IMPORTANT NOTES1. For maximum protection (lowest respirable dust production), James

Hardie recommends always using “Best” - level cutting methods where feasible.

2. NEVER use a power saw indoors.3. NEVER use a circular saw blade that does not carry the HardiBlade® logo.4. NEVER dry sweep - Use wet suppression or HEPA vacuum.5. NEVER use grinders.6. ALWAYS follow tool manufacturers’ safety recommendations.

P1 or P2 respirators should be used in conjunction with above cuttingpractices to further reduce dust exposures. Additional exposure informationis available at www.jameshardie.com.au to help you determine the mostappropriate cutting method for your job requirements. If concern still existsabout exposure levels or you do not comply with the above practices, youshould always consult a qualified industrial hygienist or contact James Hardie for further information.

Villaboard Lining:Villaboard LiningV2 13/3/09 6:11 PM Page 4

Page 5: Villaboard Lining Covers:Villaboard Lining Covers. Fibre Cement… · table 1 table 2 villaboard lining sheet sizes product length width 900 1200 1350 6mm thickness 1800 2400 2700

VILLABOARD LINING INSTALLATION MANUAL MARCH 2009 5

HardiBlade® saw bladeThe HardiBlade® saw blade used with a dust-reducing saw and HEPAvacuum extraction allows for fast, clean cutting of James Hardie fibrecement products. A dust-reducing saw uses a dust deflector or a dustcollector which can be connected to a vacuum system. When sawing,clamp a straight-edge to the sheet as a guide and run the saw base platealong the straight edge when making the cut.

HOLE-FORMINGFor smooth clean cut circular holes:� Mark the centre of the hole on the sheet.� Pre-drill a pilot hole.� Using the pilot hole as a guide, cut the hole to the appropriate diameter

with a hole saw fitted to a heavy duty electric drill.

For irregular holes:� Small rectangular or circular holes can be cut by drilling a series of

small holes around the perimeter of the hole then tapping out the wastepiece from the sheet face.

� Tap carefully to avoid damage to sheets, ensuring the sheet edges areproperly supported.

STORAGE AND HANDLINGTo avoid damage, all James Hardie building products should be storedwith edges and corners of the sheets protected from chipping.

James Hardie building products must be installed in a dry state andprotected from rain during transport and storage. The product must belaid flat under cover on a smooth level surface clear of the ground toavoid exposure to water, moisture, etc.

QUALITYJames Hardie conducts stringent quality checks to ensure any productmanufactured falls within our quality spectrum. It is the responsibility ofthe builder to ensure the product meets aesthetic requirements beforeinstallation. James Hardie will not be responsible for rectifying obviousaesthetic surface variations following installation.

Villaboard Lining:Villaboard LiningV2 13/3/09 6:11 PM Page 5

Page 6: Villaboard Lining Covers:Villaboard Lining Covers. Fibre Cement… · table 1 table 2 villaboard lining sheet sizes product length width 900 1200 1350 6mm thickness 1800 2400 2700

FRAME TOLERANCESEnsure frame is square and work from a central datum line. Frames mustbe straight and true to provide a flush face to receive the sheeting.

A suggested maximum tolerance of between 3mm and 4mm in any3000mm length of frame will give best results. Villaboard lining will notstraighten excessively warped or distorted frames and any warping maystill be visible after the internal lining is applied.

MASONRY/CONCRETE/AAC TOLERANCESCut Villaboard lining approximately 15mm less than floor to ceiling heightto allow for building tolerances. Ensure a 5-10mm building tolerance gapis provided at the floor and ceiling junctions with the Villaboard lining. SeePage 10 for specific substrate requirements.

CURVED WALLSVillaboard lining may be bent to accommodate curved walls. The minimum bending radii are shown below.

TABLE 3

NOTES1. The bending radii given above require no special pre-wetting of the

sheet and may be used on internal or external curves.2. With extra care, the sheets can be bent to the values shown in the

brackets.

To maintain the smoothness of the curve, studs are generally required atspacings as shown below.

TABLE 4

*or at one third of the sheet width, whichever is the lesser.

6 VILLABOARD LINING INSTALLATION MANUAL MARCH 2009

3 FRAMING / SUBSTRATE

GENERALVillaboard lining can be fixed to either timber framing, light gaugedomestic type steel framing and masonry, concrete or autoclavedaerated concrete (AAC) substrates. The framing and substrate used mustcomply with the relevant building regulations and standards and therequirements of this manual.

NOTE Stud spacings restrict the thickness of tiles used to finish Villaboardlining. For more information refer to the Finishes and Maintenance sectionon page 16.

TIMBERUse only seasoned timber. Unseasoned timber must not be used as it isprone to shrinkage and can cause Villaboard lining and frames to move.Studs must not be less than 38mm wide at joints.

‘Timber used for house construction must have the level of durabilityappropriate for the relevant climate and expected service life andconditions including exposure to insect attacks or to moisture, whichcould cause decay.’

Reference AS1684.2 - 1999 ‘Residential Timber Framed Construction’.

STEELThe minimum size for steel stud framing should be 64mm deep x0.55mm base metal thickness (BMT).

Steel framing must be designed in accordance with AS/NZS 4600 ‘ColdFormed Steel Structures’.

Steel sections shall be galvanised or zinc coated of 0.55mm - 1.6mmBase Metal Thickness (BMT). Studs must not be less than 38mm wide at joints.

MASONRY/CONCRETE/AACAlways ensure the substrate is given adequate time to dry out beforeinstallation of Villaboard lining. The wall surface must be clean, dry andfree of any material that will reduce an effective bond (e.g. dust, loosepaint, oil, drummy render, waterproofing or other agents, etc).

Chase walls, install services and secure to wall prior to fixing Villaboard lining.

FIGURE 1 FRAME STRAIGHTNESS

CURVED WALL MINIMUM BENDING RADII

Along length (mm) Across width (mm)

6mm Villaboard lining 1800 (1200) 2400

9mm Villaboard lining 3000 (1800) 4000

CURVED LINING - STUD SPACING

RANGE OF RADII (mm) STUD SPACING (mm)

1200 150

Above 1200 to 1800 200

Above 1800 to 3000 300

Above 3000 to 20000 *450

Above 20000 *600

Villaboard Lining:Villaboard LiningV2 13/3/09 6:11 PM Page 6

Page 7: Villaboard Lining Covers:Villaboard Lining Covers. Fibre Cement… · table 1 table 2 villaboard lining sheet sizes product length width 900 1200 1350 6mm thickness 1800 2400 2700

VILLABOARD LINING INSTALLATION MANUAL MARCH 2009 7

4 SHEET LAYOUT

GENERALInstall Villaboard lining across the framing, i.e. place the long edges of thesheet at right angles to the framing members. Villaboard lining can befixed either horizontally or vertically, however horizontal fixing isrecommended as the most convenient method in residential applications.

Sheet joints must coincide with the centre line of the framing member. Atdoor and window openings, fix sheets around the opening so sheetedges do not coincide with the side of the door or window by a minimumdistance 200mm. See Figure 2.

In areas that require greater joint performance and where glancing light isnot an issue, it is recommended that Villaboard lining be installed vertically.

5 INSTALLATIONGENERAL� Install sheets after roofing and external cladding have been installed.� Before setting the Villaboard lining sheet joints, ensure that the wall

frames are fully loaded and that the sheets have been allowed to adjust to the internal temperature.

HOT DRY CLIMATESIn hot dry climates, ensure you:

1. Store Villaboard lining sheets and James Hardie joint setting compounds undercover and out of the weather.

2. Dampen all sheet edges with clean cold water before setting of sheet joints

3. Avoid making large amounts of James Hardie base coat to prevent the James Hardie base coat compound becoming dry

4. Always use clean cold water to mix the James Hardie Base Coat

FIGURE 2 SHEET LAYOUT

Place 6mm packers along floor as temporary support for sheets. This willallow for any frame movement/shrinkage. Put first sheet in place as shown.

Ensuring the sheet is level, fix the first sheet starting from the centre ofsheet and working outwards to avoid any drumminess.

Fix remaining sheets in similar sequence.

NOTES1. For fastener selection and spacings see pages 8-11.2. Do not fix sheets to the bottom chord of roof trusses. Instead, fix to

battens or furring channels.

FIGURE 3 FIRST SHEET

FIGURE 4 FIXING FIRST SHEET

FIGURE 5 FIXING REMAINING SHEETS

Villaboard Lining:Villaboard LiningV2 13/3/09 6:11 PM Page 7

Page 8: Villaboard Lining Covers:Villaboard Lining Covers. Fibre Cement… · table 1 table 2 villaboard lining sheet sizes product length width 900 1200 1350 6mm thickness 1800 2400 2700

8 VILLABOARD LINING INSTALLATION MANUAL MARCH 2009

FASTENERSFasteners must have the appropriate level of durability required for theintended project.

Fasteners must be fully compatible with all other material that they are incontact with to ensure the durability and integrity of the assembly.

NOTE: Screws are for steel frames and nails are for timber frames.For timber, use 30mm x 2.8mm galvanised fibre cement nails with aminimum head diameter of 6mm for 6 and 9mm thick Villaboard liningand 40mm x 2.8mm galvanised fibre cement nail for 12mm thickVillaboard. Contact fastener manufacturers for more information.

For fixing 6mm Villaboard lining to 0.55 – 0.75mm BMT steel framing,use 20mm Buildex FibreZIP screws (use 30mm screws for 9 and 12mmsheets). For fixing 6mm Villaboard lining to 0.8 – 1.6mm BMT steelframing, use 22mm HardiDrive® screws (use 32mm screws for 9mm and12mm sheets).

Fasteners should be driven flush as shown in Figure 6. Fasteners shouldbe screwed as close as possible to the stud corners to avoid deflectionof the stud flange, see Figure 7.

FIXING TO FRAMED WALLSUntiled wallsWhere Villaboard lining is to be left untiled, the sheets can be fixed withfasteners or a combination of fasteners and adhesive, see Figures 8 and 9 respectively.

FIGURE 6 FASTENER DEPTH

FIGURE 7 SCREW FASTENING

NOTES1. When installing skirting tiles up to 300mm in height only fasten the

bottom of the sheet to the bottom plate at 200mm maximum centres.2. All surfaces to receive adhesive must be clean, free of dust, oil, etc.3. Ensure daubs of adhesive never coincide with permanent fastener

points, as adhesive shrinkage may cause fastener head protrusion.4. When fixing cornices it is recommended that Villaboard lining is

wetted with a sponge prior to adhesive fixing of cornices.

FIGURE 8 UNTILED FASTENING TO WALL FRAMES

FIGURE 9 FASTENER / ADHESIVE FIXING TO WALL FRAMES

Villaboard Lining:Villaboard LiningV2 13/3/09 6:11 PM Page 8

Page 9: Villaboard Lining Covers:Villaboard Lining Covers. Fibre Cement… · table 1 table 2 villaboard lining sheet sizes product length width 900 1200 1350 6mm thickness 1800 2400 2700

VILLABOARD LINING INSTALLATION MANUAL MARCH 2009 9

Tiled wallsWhere Villaboard lining is to be finished with tiles, the sheets must befixed with fasteners only as shown in Figure 10.

NOTES1. Where external perimeter flashing is used, additional noggings are

required to fix the bottom edge of the Villaboard lining. See the Wet area construction Design Manual.

2. Although not mandatory, when noggings are used it is good practiceto install the nogging row in-line to enable fixing of abutting sheets.

3. Noggings directly behind recessed sheet edges are recommendedwhere impact is expected eg. hallways in a commercial building.

FIGURE 10 TILED FASTENING TO WALL FRAMES

FIXING TO FRAMED CEILINGSFor ceiling applications either the fastener or fastener/adhesive methodcan be used. Refer to Figures 11 and 12 respectively.

NOTES1. Do not install tiles in ceiling applications.2. Do not fix sheets to the bottom chord of trusses. Batten these out

first with timber battens or steel ceiling battens.3. For fixing Villaboard above indoor pools, Ask James Hardie on 13 11 03.

FIGURE 11 FASTENING TO CEILING FRAMES

Villaboard Lining:Villaboard LiningV2 13/3/09 6:11 PM Page 9

Page 10: Villaboard Lining Covers:Villaboard Lining Covers. Fibre Cement… · table 1 table 2 villaboard lining sheet sizes product length width 900 1200 1350 6mm thickness 1800 2400 2700

BATTEN / FURRING CHANNELSNOTE: Suitable for tiled or untiled applications.

1. Substrate may be uneven and misaligned – allows correction ofirregular surfaces; allows packing out to accommodate large surfacevariations.

2. Recommended where the existing wall surface is not suitable foradhesive fixing due to flaking paint, drummy render, etc.

3. Timber battens are either fixed directly to the walls, or alternatively,metal furring channel anchor clips can be used. These are attachedto the wall prior to fitting the metal furring channels.

4. Where services are run over walls, deeper furring channels may be used.

5. Use suitable masonry fasteners to securely fix timber/steel battens orrecessed furring channels as shown in figure 14.

6. Pack behind battens as required to achieve a flat surface. 7. Support the Villaboard lining edges along the top and bottom of

the wall.

NOTES1. Timber battens or proprietary steel battens or furring channel sections

may be used. Where space is a major consideration, use recessedfurring channels which have the least section depth.

2. The spacing and fixing of anchor clips must be in accordance withthe manufacturer’s recommendations.

3. Although not mandatory, when noggings are used it is good practiceto install the nogging row in-line to enable fixing of abutting sheets.

10 VILLABOARD LINING INSTALLATION MANUAL MARCH 2009

NOTES1. Do not use adhesive only. Ensure sheet perimeter is fastened as shown.2. All surfaces to receive adhesive must be clean, free of dust, oil, etc.3. Ensure daubs of adhesive never coincide with permanent fastener

points, as adhesive shrinkage may cause fastener head protrusion.

FIXING TO MASONRY/CONCRETE/AACVillaboard lining can be installed over masonry, concrete and AeratedAutoclaved Cement (AAC) substrates by following the requirements inTable 5 below.

TABLE 5

FIXING METHOD SELECTION

METHOD SUBSTRATE APPLICATION

Batten/furring Masonry/concrete Tiled/untiled wet/drychannels AAC blocks areas with flat or

uneven substrate.

AAC fixing AAC Untiled wet/dry areas.

FIGURE 14 BATTEN / FURRING CHANNEL - HORIZONTAL LAYOUT

FIGURE 12 FASTENER / ADHESIVE FIXING TO CEILING FRAMES

Villaboard Lining:Villaboard LiningV2 13/3/09 6:11 PM Page 10

Page 11: Villaboard Lining Covers:Villaboard Lining Covers. Fibre Cement… · table 1 table 2 villaboard lining sheet sizes product length width 900 1200 1350 6mm thickness 1800 2400 2700

VILLABOARD LINING INSTALLATION MANUAL MARCH 2009 11

AUTOCLAVED AERATED CONCRETE (AAC)NOTE: Not suitable for tiled applications.

1. Chase walls, install and secure services.2. Install Villaboard lining, abutting edges of adjacent sheets.3. Drive the AAC fasteners through the Villaboard lining into the wall

until the fastener head is neatly bedded below the Villaboard liningsurface.

4. Only for standard grade AAC blocks of 500kg per cubic metre density.

NOTEUse only suitable fasteners recommended by AAC manufacturer for fixingVillaboard lining.

FIGURE 15 AAC - HORIZONTAL LAYOUT

Villaboard Lining:Villaboard LiningV2 13/3/09 6:11 PM Page 11

Page 12: Villaboard Lining Covers:Villaboard Lining Covers. Fibre Cement… · table 1 table 2 villaboard lining sheet sizes product length width 900 1200 1350 6mm thickness 1800 2400 2700

12 VILLABOARD LINING INSTALLATION MANUAL MARCH 2009

Step 2 – First coatApply James Hardie Base Coat to fill the recess with a 150mmbroadknife.

Step 3 – Embed tapeFirmly embed the perforated paper tape centrally into the joint using a150mm broadknife. Ensure that there are no voids under the tape andremove excess compound.

Step 4 – Thin layerImmediately cover tape with a thin layer of James Hardie Base Coatapplied with a 150mm broadknife.

6 JOINTS

GENERALVillaboard lining joints are set with proprietary jointing compoundsreinforced with perforated paper tape. Both recessed edge and buttjoints require joint setting by using the jointing products outlined.

The performance of joints is the responsibility of the installer, as this isgoverned by the installation practices and the standard of workmanshipsapplied. However, James Hardie considers that the recommendationsprovided in Table 6 describe best practice to reduce the risk of jointcracking or other problems.

There are various factors that can affect the performance of jointingcompounds on edge recessed fibre cement substrates. These factorsinclude the framing, movement, installation quality, vibrations, moisture,humidity, temperature, etc. To achieve satisfactory joint performance thesefactors need to be carefully considered and understood by the installerand designer then positioning joints and selecting jointing compounds.Furthermore, it is important that the jointing compound used has thephysical attributes required to perform considering these factors.

James Hardie Base Coat has been specifically developed for use withVillaboard lining and offer superior joint strength when compared with thegypsum jointing compound alternatives.

In addition, provision for movement needs to be made by the installationof control joints. See Page 15.

Extreme Hot ClimatesRefer to page 7 for additional recommendations when installing Villaboardlining in extreme hot dry climates.

TABLE 6

SET JOINTSStep 1 - PreparationEnsure that the recesses are clean and free of dust and contaminants. Ifworking conditions are hot and dry, dampen the area around the jointprior to working.

JOINTING COMPOUND RECOMMENDATIONS

APPLICATION BASE TOPPINGCOMPOUND COMPOUND

Dry walls, Untiled James Hardie James Hardie ceilings and Base Coat Top Coat

wet areas Tiled James Hardie N/ABase Coat

Villaboard Lining:Villaboard LiningV2 13/3/09 6:11 PM Page 12

Page 13: Villaboard Lining Covers:Villaboard Lining Covers. Fibre Cement… · table 1 table 2 villaboard lining sheet sizes product length width 900 1200 1350 6mm thickness 1800 2400 2700

VILLABOARD LINING INSTALLATION MANUAL MARCH 2009 13

Step 8 - Finishing coat Ensure the second coat is fully dry. Using a finishing trowel, apply a coatJames Hardie Top Coat 280mm wide centrally over the joint and featherout the edges. Allow to dry fully before sanding.

Step 9 – Fastener heads Ensure the second coat is fully dry.Apply a finishing coat of James Hardie Top Coat over fastener heads,

feathering out the edges. Allow to fully dry before sanding.

Step 5 – Fastener headsCover all fastener heads with James Hardie Base Coat. Allow to drybefore applying a second coat.

NOTE: Steps 6-9 are not required for tiled walls.

Step 6 – Second coat When the base coat is fully dry, use a 200mm wide second coat trowelto apply the James Hardie Base Coat. Apply this coat approximately180mm wide, laid down over the recess and feather the edges.

Step 7 – Fastener heads Ensure the base coat is fully dry. Apply a second coat over fastenerheads using the James Hardie Base Coat, overlapping the first by aminimum of 25mm. Allow to dry before applying finishing coat.

Villaboard Lining:Villaboard LiningV2 13/3/09 6:11 PM Page 13

Page 14: Villaboard Lining Covers:Villaboard Lining Covers. Fibre Cement… · table 1 table 2 villaboard lining sheet sizes product length width 900 1200 1350 6mm thickness 1800 2400 2700

Step 4 – Thin layer (untiled walls only)Immediately cover tape with a thin layer of James Hardie Base Coatapplied with a 150mm broadknife.

NOTE: Steps 5 and 6 are not required for tiled walls.

Step 5 – Second CoatWhen the first coat is fully dry, use a 200mm wide second coat trowel toapply the James Hardie Top Coat compound. Apply this coatapproximately 300mm wide.

Step 6 - Finishing CoatEnsure the second coat is fully dry. Using a finishing trowel, apply a coatof James Hardie Top Coat 500mm wide centrally over the joint andfeather out the edges. Allow to fully dry before sanding.

14 VILLABOARD LINING INSTALLATION MANUAL MARCH 2009

BUTT JOINTSStep 1 - PreparationWhen jointing un-recessed sheet joint, ensure that sheet edges are cleanand free of dust and contaminants. If working conditions are hot and dry,dampen the area around the joint prior to working.

Step 2 – First Coat Apply James Hardie Base Coat centrally over butt joint to 200mm widewith a 150mm broadknife.

Step 3 – Embed tapeFirmly embed the perforated paper tape centrally using a 150mm broadknife. Ensure that there are no voids under the tape and removeexcess compound.

Villaboard Lining:Villaboard LiningV2 13/3/09 6:11 PM Page 14

Page 15: Villaboard Lining Covers:Villaboard Lining Covers. Fibre Cement… · table 1 table 2 villaboard lining sheet sizes product length width 900 1200 1350 6mm thickness 1800 2400 2700

CONTROL JOINTSControl joints are required in long runs of Villaboard lining walls or ceilingsin both directions. These joints are designed to take up the structuralmovement between the sheets and the building frame. They may also berequired in ceilings where they change direction or continue into passageways. Control joints should also be provided at frame junctions/jointssuch as wall intersections.

See Table 7 for maximum control joint spacings and Figure 16 for atypical detail.

CEILINGS DIRECTLY UNDER A ROOF/CEILING/DECKNOTE: Where Villaboard linings are installed to ceilings directly underroof spaces less than 600mm, the control joints must be reduced. Inthese cases, Versilux lining is recommended. If Villaboard lining is used,control joints must be reduced to 6.0m for insulated ceilings and 3.6mfor uninsulated ceilings in both directions.

TABLE 7

* Refer to note above Table 7 on fixing Villaboard lining to ceilings directlyunder a roof/ceiling/deck application.

Horizontal control joints in walls are required at 3.6 maximum centres.When sheeting vertically a horizontal control joint is required at the sheetend when using sheets shorter than 3.6m in length.

VILLABOARD LINING INSTALLATION MANUAL MARCH 2009 15

INTERNAL CORNERS Setting of internal corners are required for untiled applications only asfollows:

� Apply bedding compound to both sides of the corner using a 70mmbroadknife.

� Fold paper tape to form an angle and embed into the corner using a100mm corner tool and cover with a skim coat.

� Allow tape coat to dry, then apply a thin finishing coat by layingadditional compound over the angle and smoothing with the corner tool.

� Allow to fully dry before sanding

EXTERNAL CORNERSSetting of external corners is required for untiled applications only asfollows:

� Fit a perforated corner angle over the external corner angle and ensurestraightness before fixing with fibre cement nails at 300mm centres.

� Apply bedding compound to both sides of the corner angle to a widthof 150mm using a broadknife. Allow to dry before applying a second coat.

� Using a straight trowel, build up the edges to 250mm from the corner.Allow to dry.

� When dry, use the straight trowel to apply a thin finishing coat, 300mmwide, to both sides of the corner angle, feathering out the edges.

� Allow to fully dry before sanding.

MAXIMUM SPACING FOR CONTROL JOINTS (m)

STEEL FRAMING TIMBER FRAMING

Greater than0.55 - 0.75mm BMT 0.8 - 1.6mm BMT

*General 9.0 6.0 7.2

Tiled walls 4.8 4.2

FIGURE 16 CONTROL JOINT

Villaboard Lining:Villaboard LiningV2 13/3/09 6:11 PM Page 15

Page 16: Villaboard Lining Covers:Villaboard Lining Covers. Fibre Cement… · table 1 table 2 villaboard lining sheet sizes product length width 900 1200 1350 6mm thickness 1800 2400 2700

16 VILLABOARD LINING INSTALLATION MANUAL MARCH 2009

7 FINISHES AND MAINTENANCE

GENERALVillaboard lining is finished with either paint, tiles or wallpaper as required.The application and maintenance of these finishes must be inaccordance with the manufacturer’s specifications.

NOTES1. For wet areas, the waterproofing requirements of all relevant codes,

standards and regulations must be met. For more information on wetarea construction refer to the James Hardie Wet area constructionDesign Manual.

2. Refer to the manufacturers’ specifications on application,compatibility and suitability of waterproofing membranes.

GLANCING LIGHTIn some instances, due to glancing light, set joints may be noticeable inVillaboard lining walls, especially where paint finishes have a high glosslevel. Work closely with your builder or designer to minimise this.

TABLE 8

Artificial lighting needs to be considered in relation to walls and ceilings(e.g. down-lights in ceilings above set joints in walls). Ceilings and walljoints should run in the direction of the light source (at right angles towindows).

Where glancing light is an issue its effect can be lessened by:

� The use of curtains or blinds.� Artificial light shading devices.� The use of light coloured, matt finish paints.

LEVEL OF FINISHESDifferent levels of finishes are typically specified for different applications.Higher levels of finishes are used to address the glancing light issues withpainted Villaboard lining referred to above. A description of the variouslevels of finishes and the jointing/coating requirements can be found in Table 8.

LEVELS OF FINISHES

LEVEL OF DEFINITION* TYPICAL JOINTING/SETTING FINISHFINISH

0 This level of finish may be useful in temporary No stopping, taping, finishing or accessories For use in areas where finishing and stoppingconstruction. are required. The work is confined to gluing is not considered necessary.

or screwing/nailing sheets in place.

1 For use in plenum areas above ceilings, in Joints and corner joints will be set with Surface free from excess jointing compound.areas where the work would generally be HardiStop bedding compound reinforced with Tool marks and ridges are generallyconcealed, or in building service corridors and perforated paper tape. acceptable.other areas not normally open to public view.

2 For use in warehouse, storage or other areas Joints and corner joints will be set with Minor tool marks and ridges are generallywhere surface appearance is not of primary HardiStop bedding compound reinforced with acceptable.concern. perforated paper tape and gypsum topping

compounds.

3 For use in areas which are to receive heavy Joints and corner joints will be set with This level of finish must be sufficiently smoothor medium texture (spray or hand applied) HardiStop bedding compound reinforced with to accept vinyl, tiles or textured coatingsfinishes or where heavy wall coverings paper perforated paper tape and gypsum topping without blemishes.are to be applied as the final decoration. This compounds.level of finish is not generally suitable wheresmooth painted surfaces or light to mediumwall coverings are specified.

4 This is generally the accepted level of finish Refer to flush jointing recommendations on For use where light-texture coatings or for domestic construction. It is used where page 11. wallpaper or other lightweight wall coveringslight textures or wall coverings and smooth are to be applied. For painted finishes in textured finishes and satin/flat/low sheen non-critical lighting areas flat and low-sheenpaints are illuminated by non-critical lighting. textured paints are to be applied. Gloss and

semi-gloss paints are not generally suitableover this level of finish as any minor blemishwill show under critical light.

The weight, texture and sheen level or wallcoverings applied over this level of finish mustbe carefully evaluated. Joints and fasteners must be adequately concealed if the wall-covering material is lightweight, contains limited pattern, has a gloss finish, or any combination of these features is present.Unbacked vinyl wall coverings are not suitableover this level of finish.

5 This level of finish is for use where gloss or Typically all joints and corner joints will have This level of finish is for use where gloss,semi-gloss paints are specified or where tape embedded in HardiStop bedding semi-gloss, low-sheen or non-textured paintscritical lighting conditions occur on satin, flat compound applied over all joints, angles, are specified or where critical lightingor low sheet paints. fastener heads and accessories. conditions occur.

A thin skim coat of finishing compound mustbe applied to the entire surface to be plastered.The surface must be finished smooth and freeof tool marks and ridges and special care mustbe taken with the application of the finishingcompound to achieve a smooth, true surfacesuitable for these critical finishes.

*Reference: AS/NZS 2589.1:1997 ‘Gypsum lining in residential and light commercial construction - Application and finishing. Part 1: Gypsum plasterboard’

Villaboard Lining:Villaboard LiningV2 13/3/09 6:11 PM Page 16

Page 17: Villaboard Lining Covers:Villaboard Lining Covers. Fibre Cement… · table 1 table 2 villaboard lining sheet sizes product length width 900 1200 1350 6mm thickness 1800 2400 2700

PAINT FINISHESPrior to application of paint finishes, remove any residual sanding dustand ensure the surface is suitable for paint application.

Always follow the paint manufacturer’s recommendations for paintsuitability, mixing and application.

NOTEUse of a ‘sealer coat’ or ‘preparation undercoat’ is recommended.

CORNICESIt is recommended that Villaboard lining is wetted with a sponge prior toadhesive fixing of cornices.

TILED FINISHESThe thicknesses of tiles used over Villaboard lining are restricted basedon stud centres and the thickness of the sheet, see Table 9.

James Hardie only recommends the use of flexible tile adhesive for tileapplication. Refer to adhesive manufacturer for suitability and applicationinformation.

NOTES1. Do not tile ceilings.2. Do not tile to walls over 3m in height.

TABLE 9

*Support angles are recommended.The suitability and positioning of support angles is to be determined by astructural engineer. Support angles need to be fixed into the supportingframe and the overall wall mass and stability needs to be considered.

MAINTENANCEJames Hardie recommends that the cleaning and maintenance of allfinishes be undertaken regularly as per the recommendations of themanufacturer. Joints must also be maintained and be free of dirt and grime.

VILLABOARD LINING INSTALLATION MANUAL MARCH 2009 17

MAXIMUM TILE THICKNESSES

VILLABOARD MAXIMUM TILE THICKNESS (mm)THICKNESS (mm)

600mm Stud Cts 450mm Stud Cts

6 9 13

9 13 18

12 18* >25*

8 PRODUCTINFORMATION

GENERALVillaboard lining is a cellulose fibre reinforced cement building product.The basic composition is Portland cement, ground sand, cellulose fibreand water.

Villaboard lining is manufactured to AS/NZS 2908.2 ’Cellulose-CementProducts Part 2: Flat Sheets’ (ISO 8336 ‘Fibre Cement Flat Sheets’).

Villaboard lining is classified Type B, Category 3 in accordance withAS/NZS 2908.2.

For Material Safety Data Sheets (MSDS) visit www.jameshardie.com.au orAsk James Hardie™ on 13 11 03.

PRODUCT MASSBased on equilibrium moisture content the approximate mass ofVillaboard lining is:

� 6mm thick - 8.3kg/m2

� 9mm thick - 12.4kg/m2

� 12mm thick - 16.6kg/m2

DURABILITYResistance to moisture/rottingVillaboard lining has demonstrated resistance to permanent moistureinduced deterioration (rotting) by passing the following tests inaccordance with AS/NZS 2908.2:

� Water permeability (Clause 8.2.2)� Warm water (Clause 8.2.4)� Heat rain (Clause 6.5)� Soak dry (Clause 8.2.5)

Resistance to FireVillaboard lining is suitable where non-combustible materials are requiredin accordance with C1.12 of the Building Code of Australia.

Villaboard lining has been tested by CSIRO and is classified as a Group 1material in accordance with Specification C1.10a of the BCA.

Villaboard lining has the following early fire hazard indices (tested to AS 1530 Part 3).

NOTES: Zero is the best possible result. The range is 0 - 10, except Ignition Index which is 0 - 20.

Resistance to termite attackBased on testing completed by CSIRO Division of Forest ProductsReport Numbers FP349 and FP274, James Hardie fibre cement hasdemonstrated resistance to termite attack.

EARLY FIRE HAZARD INDICES

Ignition index 0

Flame spread index 0

Heat evolved index 0

Smoke developed index 0 - 1

Villaboard Lining:Villaboard LiningV2 13/3/09 6:11 PM Page 17

Page 18: Villaboard Lining Covers:Villaboard Lining Covers. Fibre Cement… · table 1 table 2 villaboard lining sheet sizes product length width 900 1200 1350 6mm thickness 1800 2400 2700

18 VILLABOARD LINING INSTALLATION MANUAL MARCH 2009

NOTES

Villaboard Lining:Villaboard LiningV2 13/3/09 6:11 PM Page 18

Page 19: Villaboard Lining Covers:Villaboard Lining Covers. Fibre Cement… · table 1 table 2 villaboard lining sheet sizes product length width 900 1200 1350 6mm thickness 1800 2400 2700

VILLABOARD LINING INSTALLATION MANUAL MARCH 2009 19

9 WARRANTY

James Hardie Australia Pty Limited ("James Hardie") warrants for a periodof 10 years from the date of purchase that the Villaboard® lining (the"Product"), will be free from defects due to defective factory workmanshipor materials and, subject to compliance with the conditions below, will beresistant to cracking, rotting, fire and damage from termite attacks to theextent set out in James Hardie’s relevant published literature current at thetime of installation. James Hardie warrants for a period of 12 months fromthe date of purchase that the accessories supplied by James Hardie willbe free from defects due to defective factory workmanship or materials.

Nothing in this document shall exclude or modify any legal rights acustomer may have under the Trade Practices Act or otherwise whichcannot be excluded or modified at law.

CONDITIONS OF WARRANTYThe warranty is strictly subject to the following conditions:

a) James Hardie will not be liable for breach of warranty unless theclaimant provides proof of purchase and makes a written claim eitherwithin 30 days after the defect would have become reasonablyapparent or, if the defect was reasonably apparent prior toinstallation, then the claim must be made prior to installation;

b) this warranty is not transferable;

c) the Product must be installed and maintained strictly in accordancewith the relevant James Hardie literature current at the time ofinstallation and must be installed in conjunction with the componentsor products specified in the literature. Further, all other products,including coating and jointing systems, applied to or used inconjunction with the Product must be applied or installed andmaintained strictly in accordance with the relevant manufacturer’sinstructions and good trade practice;

d) the project must be designed and constructed in strict compliancewith all relevant provisions of the current BCA, regulations andstandards;

e) the claimant’s sole remedy for breach of warranty is (at JamesHardie’s option) that James Hardie will either supply replacementproduct, rectify the affected product or pay for the cost of thereplacement or rectification of the affected product;

f) James Hardie will not be liable for any losses or damages (whetherdirect or indirect) including property damage or personal injury,consequential loss, economic loss or loss of profits, arising incontract or negligence or howsoever arising. Without limiting theforegoing James Hardie will not be liable for any claims, damages ordefects arising from or in any way attributable to poor workmanship,poor design or detailing, settlement or structural movement and/ormovement of materials to which the Product is attached, incorrectdesign of the structure, acts of God including but not limited toearthquakes, cyclones, floods or other severe weather conditions orunusual climatic conditions, efflorescence or performance ofpaint/coatings applied to the Product, normal wear and tear, growthof mould, mildew, fungi, bacteria, or any organism on any Productsurface or Product (whether on the exposed or unexposed surfaces);

g) all warranties, conditions, liabilities and obligations other than thosespecified in this warranty are excluded to the fullest extent allowed by law;

h) if meeting a claim under this warranty involves re-coating ofProducts, there may be slight colour differences between the originaland replacement Products due to the effects of weathering andvariations in materials over time.

DISCLAIMERThe recommendations in James Hardie’s literature are based on goodbuilding practice, but are not an exhaustive statement of all relevantinformation and are subject to conditions (c), (d), (f) and (g) above.Further, as the successful performance of the relevant system dependson numerous factors outside the control of James Hardie (eg quality ofworkmanship and design) James Hardie shall not be liable for therecommendations in that literature and the performance of the relevantsystem, including its suitability for any purpose or ability to satisfy therelevant provisions of the Building Code of Australia ("BCA"), regulationsand standards.

Villaboard Lining:Villaboard LiningV2 13/3/09 6:11 PM Page 19

Page 20: Villaboard Lining Covers:Villaboard Lining Covers. Fibre Cement… · table 1 table 2 villaboard lining sheet sizes product length width 900 1200 1350 6mm thickness 1800 2400 2700

© 2007 James Hardie Australia Pty Ltd. TM and ® denotes a trademark or registered mark owned by James Hardie International Finance BV. JHML112613

Villaboard Lining Covers:Villaboard Lining Covers 13/3/09 6:04 PM Page 2