UL-LISTED FOR WET LOCATIONS - Kelvix · Dim Output Voltage VOUT-TRIAC PWM Output 0 - 100 % of VOUT...
Transcript of UL-LISTED FOR WET LOCATIONS - Kelvix · Dim Output Voltage VOUT-TRIAC PWM Output 0 - 100 % of VOUT...
102819DMQuestions/Support | 800-789-3810 | [email protected]
Fixture Type:
Project:
Location:
HLV9696 WATT—24 VOLT | CLASS 2 SUPPLY
SPECIFICATIONSModel HLV96
Input Voltage 100 – 277 VAC
Output Voltage 24VDC / Constant Voltage
Max. Wattage 96 W
Temp Range -20 °F – 158 °F
Dimensions 8.813" × 2.875" × 1.438"
Classification Class 2
PRODUCT FEATURES
• 431 Hz / Flicker-free Dimming Down to 1%
• Incandescent, ELV, MLV, or 0-10V Dimming
• Protections: Short Circuit / Over Current / Over Voltage
• Free Air Convection Cooling
• Dry / Damp / Wet Rated
• UL-listed Class 2 for Indoor / Outdoor Use
Conforms to ANSI/UL Standard 2108
Certified tp CAN/CSA Standard C22.2 No. 250.0
CLASS2
UL-LISTED FOR WET LOCATIONS
2.875"
1.438"
8.813"
102819DMQuestions/Support | 800-789-3810 | [email protected]
HLV9696 WATT—24 VOLT | CLASS 2 SUPPLY
SPECIFICATION Parameters Symbols Test Conditions / Comment Min Typ Max Units
INPUTInput Voltage VIN 90 305 VAC
Rated Input Voltage VIN RATEDDimming with TRIAC / ELV / CL Dimmer 100 120 VAC
No Phase Cut Dimming 100 277 VAC
Input Frequency fline 47 50 / 60 63 HzInput Current IIN Full Load,VIN = 100 VAC 1.3 A
GENERAL CHARACTERISTICS
Power Factor PF30% – 100% Load, VIN = 120 VAC 0.95 PF60% – 100% Load, VIN = 230 VAC 0.9 PF70% – 100% Load, VIN = 277 VAC 0.9 PF
Total Harmonic Distortion THD
30% – 100% Load, VIN = 120 VAC 20 %60% – 100% Load, VIN = 230 VAC 20 %
70% – 100% Load, VIN = 277 VAC 20 %
Efficiency ηFull Load, VIN = 120 VAC 81 83 %Full Load, VIN = 230 VAC 83 85 %Full Load, VIN = 277 VAC 82 84 %
Turn On Delay Time Ton_delay Cold Start, No TRIAC Dimmer 0.3 0.5 SOUTPUT
Output Voltage VOUT No Dimming 23.3 24 24.7 VNo Load
Output Voltage VNO LOAD No Load, No Dimming 23.7 24 24.3 V
Output Current IOUT 0 4000 mALine Regulation VOUT-LINE 1 %Load Regulation VOUT-LOAD IOUT from MIN. to MAX. 2 %Ripple Voltage VOUT-RIPPLE Full Load, (pk-to-pk) / Average 3 %
Output Voltage Overshoot VOVERSHOOT Turning Power ON 3 %
No Load Power Dissipation PNO-LOAD 4 W
0-10V OR RESISTOR DIMMINGThe 0-10 V or resistor dimming is a dimming manner that can be used to dim the output voltage via a standard commercial wall dimmer (0-10 VDC) or an external control voltage source (0-10 VDC) or external resistor.
The dimming range is 100 % VOUT to 1 % VOUT. When VDIM is 9-10 VDC, the output voltage maintains 100 % VOUT, and when VDIM is below 0.3 V, the output voltage is 1 % VOUT.Absolute Maximum
Voltage on 0-10 V Pin
VDIM -2 15 V
Source Current on 0-10 V
Dimming PinIDIM 100 uA
VDIM Voltage for Full Bright VDIM-MAX 9 V
Minimum Output Voltage VOUT-MAX VDIM = 0.3V % of VOUT
External Resistor Value at Full Bright RExternal-MAX 90 kΩ
MODEL LIST Model Name Rated Input Voltage Rated Output Power Rated Output Voltage Output Current Note
HLV96100–277 VAC
96 W 24 V 0-4000 mA 3 In 1 Dimming100–120 VAC
102819DMQuestions/Support | 800-789-3810 | [email protected]
SPECIFICATION (CONT.)Parameters Symbols Test Conditions / Comment Min Typ Max Units
PWM DIMMINGThe PWM dimming is a dimming manner that can be used to dim the output voltage via the duty cycle of PWM signal.
The dimming range is 100 % VOUT to 1 % VOUT. When the duty cycle is 90 % to 100 %, the output voltage reaches 100 % VOUT, and the output voltage maintains 1 % VOUT when the duty cycle below 3 %.
PWM Frequency fPWM 0.1 1 KHzHigh Level Voltage
of PWM Signal VPWM-High VPWM-High Affect Output Voltage - 10 - V
Lower Level Voltage of
PWM SignalVPWM-Low VPWM-Low Affect Output Voltage 0 1 V
Minimum Output Voltage VOUT-MIN 1 % of VOUT
TRIAC DIMMINGThe unit is compatible with leading-edge and trailing-edge dimmer.
Input Voltage VIN-TRIAC DIM 100 120 VACDim Output Voltage VOUT-TRIAC PWM Output 0 - 100 % of VOUT
Suggest Load Range PSuggest VIN from 100 VAC to 120 VAC 9.6 96 W
PROTECTIONOver Voltage Protection VOVP Latch Off Mode 28 32 36 V
Over Current Protection IOCP
It will recover automatically after fault condition is removed. 4.0 4.1 4.5 A
Over Temperature Protection TOTP
If the case temperature exceeds OTP point, the output voltage of the driver is
automatically reduced.90 95 100 ℃
Short Circuit Protection It will recover automatically after fault conditions is removed.
ENVIRONMENTStorage
Temperature TStorage Humidity: 5 % RH to 95 % RH -40 - +85 ℃
Operating Relative Humidity Ha Non Condensing 10 95 %
OTHERS
Life Time TLife Full load, 65 ℃ Case Temperature 30 kHrs
MTBF TMTBFFull Load, 120 VAC Input, 25 ℃
Ambient Temperature200 kHrs
Dimension L × W × H 224 mm × 73 mm × 36.5 mm (8.813" × 2.875" × 1.438")
SAFETY COMPLIANCEUL Listed UL8750 Compliance to UL1310 Class 2, CSA-C22.2 No. 107.1
EMC COMPLIANCEFCC Part 15B Conducted Emission Test and Radiated Emission Test
Note: Unless otherwise specified, all the above parameters are measured at ambient temperature of 25 ℃ and VIN = 100 – 277 VAC.
HLV9696 WATT—24 VOLT | CLASS 2 SUPPLY
102819DMQuestions/Support | 800-789-3810 | [email protected]
TYPICAL APPLICATIONPRIMARY SIDE DIMMING (120V ONLY)
SECONDARY SIDE SWITCHING (120–277V)
SECONDARY SIDE DIMMING (0–10V)
SECONDARY SIDE DIMMING (DMX)
HLV9696 WATT—24 VOLT | CLASS 2 SUPPLY