UL-LISTED FOR WET LOCATIONS - Kelvix · Dim Output Voltage VOUT-TRIAC PWM Output 0 - 100 % of VOUT...

4
102819DM Questions/Support | 800-789-3810 | [email protected] Fixture Type: Project: Location: HLV96 96 WATT—24 VOLT | CLASS 2 SUPPLY SPECIFICATIONS Model HLV96 Input Voltage 100 – 277 VAC Output Voltage 24VDC / Constant Voltage Max. Wattage 96 W Temp Range -20 °F – 158 °F Dimensions 8.813" × 2.875" × 1.438" Classification Class 2 PRODUCT FEATURES 431 Hz / Flicker-free Dimming Down to 1% Incandescent, ELV, MLV, or 0-10V Dimming Protections: Short Circuit / Over Current / Over Voltage Free Air Convection Cooling Dry / Damp / Wet Rated UL-listed Class 2 for Indoor / Outdoor Use Conforms to ANSI/UL Standard 2108 Certified tp CAN/CSA Standard C22.2 No. 250.0 CLASS 2 UL-LISTED FOR WET LOCATIONS 2.875" 1.438" 8.813"

Transcript of UL-LISTED FOR WET LOCATIONS - Kelvix · Dim Output Voltage VOUT-TRIAC PWM Output 0 - 100 % of VOUT...

102819DMQuestions/Support | 800-789-3810 | [email protected]

Fixture Type:

Project:

Location:

HLV9696 WATT—24 VOLT | CLASS 2 SUPPLY

SPECIFICATIONSModel HLV96

Input Voltage 100 – 277 VAC

Output Voltage 24VDC / Constant Voltage

Max. Wattage 96 W

Temp Range -20 °F – 158 °F

Dimensions 8.813" × 2.875" × 1.438"

Classification Class 2

PRODUCT FEATURES

• 431 Hz / Flicker-free Dimming Down to 1%

• Incandescent, ELV, MLV, or 0-10V Dimming

• Protections: Short Circuit / Over Current / Over Voltage

• Free Air Convection Cooling

• Dry / Damp / Wet Rated

• UL-listed Class 2 for Indoor / Outdoor Use

Conforms to ANSI/UL Standard 2108

Certified tp CAN/CSA Standard C22.2 No. 250.0

CLASS2

UL-LISTED FOR WET LOCATIONS

2.875"

1.438"

8.813"

102819DMQuestions/Support | 800-789-3810 | [email protected]

HLV9696 WATT—24 VOLT | CLASS 2 SUPPLY

SPECIFICATION Parameters Symbols Test Conditions / Comment Min Typ Max Units

INPUTInput Voltage VIN 90 305 VAC

Rated Input Voltage VIN RATEDDimming with TRIAC / ELV / CL Dimmer 100 120 VAC

No Phase Cut Dimming 100 277 VAC

Input Frequency fline 47 50 / 60 63 HzInput Current IIN Full Load,VIN = 100 VAC 1.3 A

GENERAL CHARACTERISTICS

Power Factor PF30% – 100% Load, VIN = 120 VAC 0.95 PF60% – 100% Load, VIN = 230 VAC 0.9 PF70% – 100% Load, VIN = 277 VAC 0.9 PF

Total Harmonic Distortion THD

30% – 100% Load, VIN = 120 VAC 20 %60% – 100% Load, VIN = 230 VAC 20 %

70% – 100% Load, VIN = 277 VAC 20 %

Efficiency ηFull Load, VIN = 120 VAC 81 83 %Full Load, VIN = 230 VAC 83 85 %Full Load, VIN = 277 VAC 82 84 %

Turn On Delay Time Ton_delay Cold Start, No TRIAC Dimmer 0.3 0.5 SOUTPUT

Output Voltage VOUT No Dimming 23.3 24 24.7 VNo Load

Output Voltage VNO LOAD No Load, No Dimming 23.7 24 24.3 V

Output Current IOUT 0 4000 mALine Regulation VOUT-LINE 1 %Load Regulation VOUT-LOAD IOUT from MIN. to MAX. 2 %Ripple Voltage VOUT-RIPPLE Full Load, (pk-to-pk) / Average 3 %

Output Voltage Overshoot VOVERSHOOT Turning Power ON 3 %

No Load Power Dissipation PNO-LOAD 4 W

0-10V OR RESISTOR DIMMINGThe 0-10 V or resistor dimming is a dimming manner that can be used to dim the output voltage via a standard commercial wall dimmer (0-10 VDC) or an external control voltage source (0-10 VDC) or external resistor.

The dimming range is 100 % VOUT to 1 % VOUT. When VDIM is 9-10 VDC, the output voltage maintains 100 % VOUT, and when VDIM is below 0.3 V, the output voltage is 1 % VOUT.Absolute Maximum

Voltage on 0-10 V Pin

VDIM -2 15 V

Source Current on 0-10 V

Dimming PinIDIM 100 uA

VDIM Voltage for Full Bright VDIM-MAX 9 V

Minimum Output Voltage VOUT-MAX VDIM = 0.3V % of VOUT

External Resistor Value at Full Bright RExternal-MAX 90 kΩ

MODEL LIST Model Name Rated Input Voltage Rated Output Power Rated Output Voltage Output Current Note

HLV96100–277 VAC

96 W 24 V 0-4000 mA 3 In 1 Dimming100–120 VAC

102819DMQuestions/Support | 800-789-3810 | [email protected]

SPECIFICATION (CONT.)Parameters Symbols Test Conditions / Comment Min Typ Max Units

PWM DIMMINGThe PWM dimming is a dimming manner that can be used to dim the output voltage via the duty cycle of PWM signal.

The dimming range is 100 % VOUT to 1 % VOUT. When the duty cycle is 90 % to 100 %, the output voltage reaches 100 % VOUT, and the output voltage maintains 1 % VOUT when the duty cycle below 3 %.

PWM Frequency fPWM 0.1 1 KHzHigh Level Voltage

of PWM Signal VPWM-High VPWM-High Affect Output Voltage - 10 - V

Lower Level Voltage of

PWM SignalVPWM-Low VPWM-Low Affect Output Voltage 0 1 V

Minimum Output Voltage VOUT-MIN 1 % of VOUT

TRIAC DIMMINGThe unit is compatible with leading-edge and trailing-edge dimmer.

Input Voltage VIN-TRIAC DIM 100 120 VACDim Output Voltage VOUT-TRIAC PWM Output 0 - 100 % of VOUT

Suggest Load Range PSuggest VIN from 100 VAC to 120 VAC 9.6 96 W

PROTECTIONOver Voltage Protection VOVP Latch Off Mode 28 32 36 V

Over Current Protection IOCP

It will recover automatically after fault condition is removed. 4.0 4.1 4.5 A

Over Temperature Protection TOTP

If the case temperature exceeds OTP point, the output voltage of the driver is

automatically reduced.90 95 100 ℃

Short Circuit Protection It will recover automatically after fault conditions is removed.

ENVIRONMENTStorage

Temperature TStorage Humidity: 5 % RH to 95 % RH -40 - +85 ℃

Operating Relative Humidity Ha Non Condensing 10 95 %

OTHERS

Life Time TLife Full load, 65 ℃ Case Temperature 30 kHrs

MTBF TMTBFFull Load, 120 VAC Input, 25 ℃

Ambient Temperature200 kHrs

Dimension L × W × H 224 mm × 73 mm × 36.5 mm (8.813" × 2.875" × 1.438")

SAFETY COMPLIANCEUL Listed UL8750 Compliance to UL1310 Class 2, CSA-C22.2 No. 107.1

EMC COMPLIANCEFCC Part 15B Conducted Emission Test and Radiated Emission Test

Note: Unless otherwise specified, all the above parameters are measured at ambient temperature of 25 ℃ and VIN = 100 – 277 VAC.

HLV9696 WATT—24 VOLT | CLASS 2 SUPPLY

102819DMQuestions/Support | 800-789-3810 | [email protected]

TYPICAL APPLICATIONPRIMARY SIDE DIMMING (120V ONLY)

SECONDARY SIDE SWITCHING (120–277V)

SECONDARY SIDE DIMMING (0–10V)

SECONDARY SIDE DIMMING (DMX)