Thermal Mass Flow Meter (Series MST) - Home of MaxiFlo … · · 2017-01-19MAXIFLOTM Thermal Mass...
Transcript of Thermal Mass Flow Meter (Series MST) - Home of MaxiFlo … · · 2017-01-19MAXIFLOTM Thermal Mass...
MAXIFLOTM Thermal Mass Flowmeter
1
Overview MaxiFloTM MST series Thermal Mass Flow Meter is the instrument of choice for reliable and accurate measurement of mass flows for various gases. It measures the mass flow of gas based on constant temperature differential technology and is able to measure gas flow in the range between 0 and 160 NMPS. Because neither temperature nor pressure measurement is required, MST series reduces installation cost and vastly improves system accuracy. The meter is easily installed or retrofitted with minimum downtime and provides superior, long-term process productivity and easy serviceability. MST series can have either inline sensor or insertion sensor. The inline sensor size ranges from 1” (25mm) to 12” (300mm) with either NPT thread connection or flange connection. The insertion sensors are available from 1” (25 mm) and above with the sensor mounting option of either compression fitting or flange. The indicator/transmitter provides a 4-20mA, pulse, RS-485, HART, alarm, etc. Main Features
· Can measure gas/air flow without pressure or temperature compensation
· It can measure mass flow and also volume flow.
· No moving parts
· High accuracy of 1.0% of reading/1.5% FS ±0.5
Reading
· Wide turndown ratio of 100:1
· Field-programming capability available
· SUS 316 stainless steel material for sensor body and sensing elements
· Lightening protection Measuring Principle MST series Thermal Mass Flow Meter utilizes both constant temperature differential (dT) and constant current technologies. The sensor has two elements. The reference RTD measures the gas temperature. The electronics heats the heated element above the gas temperature. It is the job of the electronics to maintain a constant current (MST100 & 300) or a constant dT between the gas temperature and the heated element (MST200). The electronics measures the dT and the current to measure the flow rate.
100% Customer Satisfaction
Thermal Mass Flow Meter
(Series MST)
THER
MAL M
ASS
FLOW
METE
R
MST100
MST200
MST300
MAXIFLOTM Thermal Mass Flowmeter
2
Indicator/Transmitter Models
Model Description
MST100 Graphic LCD Indicator with Totalizer Principle: Constant Current Method
MST200
Graphic Backlight LCD Indicator with Totalizer Principle: Constant Temperature Method
MST300
Graphic LCD Indicator with Totalizer Principle: Constant Current Method Only for Air and Nitrogen Gases
The indicator/transmitter can be mounted integrated with the sensor or mounted separately by option.
Sensors
Division Description
Connection /Fitting Pipe Size
Inline NPT Thread 1” ~ 12”
(25 ~ 300mm) Flange
Insertion Compression Fitting 1” ~ 40”
(25 ~ 1000mm) Flange Fitting
For insertion type sensors, mounting accessories (such as compression fitting and flange fitting are supplied upon request.
INDICATORS AND SENSORS MST Series Thermal Mass Flowmeter
MST200 with Insertion Sensor 2” ~ 40” (50~1000mm)
MST100 with Inline Sensor 1”~12” (25~300mm)
MST100 with Insertion Sensor 2” ~ 40” (50~1000mm)
MST300 with Insertion Sensor 1” ~ 12” (25~300mm)
MAXIFLOTM Thermal Mass Flowmeter
3
Technical Specifications MST100 MST200 MST300
Technology &
Feature Constant Current Method Constant Temperature Method
Constant Current Method Special Edition Only for Air and Nitrogen Gases
Flow Velocity Range
0.6 ~ 60 Nm/s (Optionally up to 160 Nm/s)
Indicator/Converte
r
Flow Rate, Temperature, Density, Frequency &
Totalizer Graphic LCD
Flow Rate & Totalizer 16 x 2 Alphanumeric LCD with
Backlight
Flow Rate, Totalizer, Velocity & Temperature
Graphic LCD
Key 3-keys 4-keys 3-keys
Output 4-20mA, Frequency, RS-485 (MODBUS), HART
4-20mA, Pulse, RS-485 & Alarm
4-20mA, Frequency, RS-485 (MODBUS), HART
Flow Rate Units Fixed at the Factory
Nm3/h, Nm3/m, Kg/d, Kg/hr, Kg/m, Kg/s, SCFM, SCFH, Lb/d, Lb/h, Lb/m, Lb/s, NLPH, NLPM, SLPM, SMPS, NMPS, SFPM
Fixed at the Factory
Material Indicator Housing – Cast Aluminum, Sensor – SUS316 Max.
Pressure 16 barG
Max. Temperat
ure Indicator: -40~ 150℃
Sensor: Standard: -40 ~ 121℃, High-Temperature: 0 ~ 204℃
Indicator: -40~ 150℃
Enclosure Weather proof (NEMA
4x), IP-65, Ex-proof (Exd IIC T3)
Weather proof (NEMA 4x), IP-65
Weather proof (NEMA 4x), IP-65
Power Supply 24VDC/220VAC 24VDC/220VAC 24VDC
Accuracy ±1.5% FS ±0.5 Reading ±1.0% of Reading ±1.5% FS ±0.5 Reading
Repeatability ±0.5%, Reading ±0.2%, Full Scale ±0.5%, Reading
SPECIFICATIONS
MAXIFLOTM Thermal Mass Flowmeter
4
DIMENSIONS – MST100/300
MST100
Compression Fitting Flange Fitting
MST300
MAXIFLOTM Thermal Mass Flowmeter
5
DIMENSIONS – MST200
In-Line Type
Insertion Type
Flange Connection Screw Connection
Remote Configuration
Compression Fitting Smart Electronics
Remote Configuration
MAXIFLOTM Thermal Mass Flowmeter
6
Model Selection Guide
MST###-###-#-##-##/Options Code
Model Designator
Constant-Current Method Thermal Mass Flow Meter MST100
Constant-Temperature Method Thermal Mass Flow Meter MST200
Constant-Current Method Thermal Mass Flow Meter for N2 Gas and Air MST300
Pipe Size in mm (Describe the dimensions in case of duct) ###
Indicator/Converter Integral I
Remote R
Sensor
Inline Type Threaded (NPT, PT, etc.) FT
Flanged (JIS, ANSI, DIN, etc.) FF
Insertion Type
Compression Fitting (1/2” or 3/4" NPT) IC
Flanged Fitting IF
Power Supply 220VAC P1
24VDC P2
Options
HART instead of RS-485 HT
Pressure Input (Built-in, for MST100 only) PI
Flow Meter Cleaning for Oxygen CL
MAXIFLOTM is a registered trademark of Seil Enterprise Co.
Seil Enterprise Co. Seoul Korea www.maxiflo.co.kr