Cathodic Protection Test Stations The Good, The Bad, and The Ugly! Jeff Schramuk NACE CP Specialist #7695 630‐235‐1559 www.cpsolutionsinc.net 1

Transcript of Test Stations Good-Bad-Ugly

Page 1: Test Stations Good-Bad-Ugly

CathodicProtectionTestStations

TheGood,TheBad,andTheUgly!

JeffSchramukNACECPSpecialist#7695

630‐235‐1559www.cpsolutionsinc.net

1

Page 2: Test Stations Good-Bad-Ugly

Post‐TypeTestStation– ThirdPartyDamage

Wasn’t it obvious?

2

Page 3: Test Stations Good-Bad-Ugly

HowNOTtoWiretheTerminalBoard

Is there room for any more wires?

Lost my head!

3

Page 4: Test Stations Good-Bad-Ugly

HowNOTtoInstalltheTerminalBoard

Can I close the test station cover without

breaking off the wires?

Will the enclosure

drain?

4

Page 5: Test Stations Good-Bad-Ugly

FlushTestStation– WhoWillBeAbletoReadIt?

Future Traffic Lane

5

Page 6: Test Stations Good-Bad-Ugly

TerminalBoardw/oRingTongueWireConnectors

Test station wires merely wrapped around terminal posts will slip off when cover is twisted to close-lock

Bad Practice!

6

Page 7: Test Stations Good-Bad-Ugly

“Economy”Flush‐TypeTestStation&TerminalBoard

Can you see it?

Terminal Corrosion?

Bad Practice!

7

Page 8: Test Stations Good-Bad-Ugly

Flush‐StyleTestStation(ConcreteFilled)

Wires encased in concrete sidewalk cavity w/o proper drainage

Bad Practice!

8

Page 9: Test Stations Good-Bad-Ugly

FlushTestStation(WireHousingCutOff)

Bottom shaft of test station has been cut off

Bad Practice!

9

Page 10: Test Stations Good-Bad-Ugly

FlushTestStation(TooManyWires)

Where’s the Decoder?

Bad Practice!

10

Page 11: Test Stations Good-Bad-Ugly

CPTHHN‐THWNTestStationWireFailures

11Insulation crackedPoor Splice Technique

Bad Practice!

Page 12: Test Stations Good-Bad-Ugly

TestStationWiresNotProperlyBuried

Test station wires exposedBad

Practice!12

Page 13: Test Stations Good-Bad-Ugly

13

ShoddyRingTongueConnectorsonTestWires

If ring tongue connectors are used, make sure they are properly connected to the test wires!

Bad Practice!

Page 14: Test Stations Good-Bad-Ugly

TypicalUSACEFlushTestStationInstallation

Two test leads (gray) are

connected to the pipe. One pipe lead is connected to the anode (red wire) via the wire shunt. The other pipe lead is

terminated separately for

testing purposes.

Good Job!

14

Page 15: Test Stations Good-Bad-Ugly

T.S.Head– InstalledwithoutPEMountingPost

Result: Water and Silt Accumulates within Upside-Down Test Station

Problem: No Crushed Stone Installed on Bottom of Enclosure

Problem: Terminal Board Not Installed Upright within Enclosure

Result: Water and Silt Fills Test Station Enclosure

water

silt

15

Page 16: Test Stations Good-Bad-Ugly

16

CPTestStationWires– Protected UptoGrade

Test Station terminal board is mounted to top

of PE pipe

CP Test WiresRed: AnodesBlue: Pipe

Yellow: Reference Electrode

PE pipe protects CP wires down to bottom of

pipe trench

Page 17: Test Stations Good-Bad-Ugly

17

T.S.Enclosurew/oProperDrainage–After1Year

Cap is optional!?

Just cover it up!?

Bad Practice!

Page 18: Test Stations Good-Bad-Ugly

Interior of Enclosure w/TS Head (Damaged)Flush Enclosure

Standing water due to poor drainage from enclosure

Enclosure is poorly placed in low spot along roadside

T.S.Enclosurew/oDrainage–RealityPoursIn

18

Page 19: Test Stations Good-Bad-Ugly

TestStationEnclosure– AreTestWiresOptional?

Bad Practice!

Interior of Test Station Enclosure filled with mud but no test wires19

Page 20: Test Stations Good-Bad-Ugly

T.S.Enclosures– Designedfor“Incidental”Traffic

Bad Practice!Test station enclosures should never be paved over

20

Page 21: Test Stations Good-Bad-Ugly

ProperDrainageandWiringareImportant

ITS - No Gravel Drainage CTS - Proper Gravel Drainage

Disconnected wire from ring tongueMud fills bottom of enclosure21

Page 22: Test Stations Good-Bad-Ugly

AnodesWorkBetterWhenTheyAreConnected

Test Station w/Cover Removed

Terminal Board Front Terminal Board Back

Note: No wire shunt connection is installedbetween bonded 2 x #8 anode cables (red)and 1 x #8 structure (blue) cable

Wet sand fills bottom of enclosure22

Page 23: Test Stations Good-Bad-Ugly

Properly‐WiredAnodeTSTerminalBoard

Screw Terminals (Shunt & Shorting Bar) Binding Posts (All Incoming TS Wires)

23

Page 24: Test Stations Good-Bad-Ugly

InstalltheCorrect(Specified)TestStation

The test station cover is not suitable for teststations set within a flush enclosure since thecap’s “locking tab” cannot be easily released.

24

Page 25: Test Stations Good-Bad-Ugly

25

ASuitablePost‐TypeCPTestStationInstallation

Shown w/cap removed

Good Job!

Page 26: Test Stations Good-Bad-Ugly

26Concrete pad is optional per owner

Terminal board is mounted to PE Pipe

Crushed gravel provides drainage

Good Job!

SuitableFlush‐TypeCPTestStationInstallation

Page 27: Test Stations Good-Bad-Ugly

27

MoreFlush‐TypeCPTestStationInstallations

Good Job!

Note siltation - gravel allows thorough drainage

Marker Post is Optional

Page 28: Test Stations Good-Bad-Ugly

28

JeffSchramukNACECPSpecialist#7695

630‐235‐1559www.cpsolutionsinc.net

DoYouNeedMoreInformation

RegardingYourSpecificProject?

PleaseContactMe!

TechnicalAssistanceisAlwaysAvailable

All material in this presentation is, unless otherwise stated, the property of CP Solutions, Inc (CPSI). Copyright and other intellectual property laws protect these materials. Reproduction or retransmission of the materials, in whole or in part, in any manner, without the prior written consent of CPSI, is a violation of copyright law.