SOUTH Distribution System - GE · PDF fileEmail: [email protected] Toll Free No: 18001024343...

32
Distribution System MCBs, RCCBs, Distribution Boards Keeping you protected

Transcript of SOUTH Distribution System - GE · PDF fileEmail: [email protected] Toll Free No: 18001024343...

Page 1: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

Distribution SystemMCBs, RCCBs, Distribution Boards

Keeping you protected

REGIONAL OFFICES

NORTH

BRANCH OFFICES

New Delhi

GE India Industrial Pvt. Ltd.71/1, Shivaji MargNew Delhi-110015Ph: (011) 45052277/8Fax: (011) 25928088

Chandigarh

GE India Industrial Pvt. Ltd.SCO No. 72 & 73, First FloorSector 8/C, Madhya MargChandigarh-160008Ph: (0172) 3982908-10Fax: (0172) 3982905

Jaipur

GE India Industrial Pvt. Ltd.448, 4th Floor, Ganapati PlazaM.I. Road, Jaipur-302001Ph: (0141) 5112802Fax: (0141) 2389012

Lucknow

GE India Industrial Pvt. Ltd.101, Ace Business Center19, Vidhan Sabha MargLucknow-226001Ph: (0522) 3203808, 3012444/666Fax: (0522) 4045909

SOUTH

Bangalore

GE India Industrial Pvt. Ltd.The Millenia, Level-6, Tower B1 & 2, Murphy Road, UlsoorBangalore-560008Ph: (080) 41434000Fax: (080) 41434199

Chennai

GE India Industrial Pvt. Ltd.Temple Tower, 6th Floor476, (New No. 672) Anna SalaiNandanamChennai-600035Ph: (044) 45070470-84Fax: (044) 45070474

Coimbatore

GE India Industrial Pvt. Ltd.No.36/6 & 7, 1st FloorAshirwad BuildingD.B.Road, R.S. PuramCoimbatore-641002Ph: (0422) 4393520 / 4393529

WEST

Mumbai

GE India Industrial Pvt. Ltd.361/362, Solitaire Corporate ParkM. Vasanji Road, ChakalaAndheri (E), Mumbai-400093Ph: (022) 40101610Fax: (022) 40101611

EAST

Kolkata

GE India Industrial Pvt. Ltd.Horizon Building, 4th Floor 57, Chowringhee RoadKolkata-700071Ph: (033) 40034056Fax: (033) 40034071

Works:GE India Industrial Pvt. Ltd.Plot No. 42/1 & 45/14Electronic City - Phase IIBangalore-560100Ph: (080) 41113000Fax: (080) 28528469/552

HO:GE India Industrial Pvt. Ltd.The Millenia, Level-6, Tower B1 & 2, Murphy Road, UlsoorBangalore-560008Ph: (080) 41434000Fax: (080) 41434199Email: [email protected]

Toll Free No:18001024343

Customer Care:[email protected]

We are committed to continuous development and improvement of our products and the specifications aresubject to change without notice. For product availability and latest prices, please contact GE Sales Team.

For any further information, visit us at http://www.geindustrial.com

g and General Electric are registered trade marks of General Electric Co. USA©

Ahmedabad

GE India Industrial Pvt. Ltd.405-406, Kirtiman ComplexKinariwala House, Behind CitibankOff C.G. Road, Ahmedabad-380006Ph: (079) 65427385/55427389Fax: (079) 26460637

Pune

GE Money Financial Services LimitedShop No. 405-410, 4th FloorCity Point, Dhole Patil RoadPune-411001Mob: +91 9850867507

Cochin

GE India Industrial Pvt. Ltd.Mayur Business Center & MotelChittur Road, Pullepadi JunctionCochin-682035Ph: (0484) 2364139Fax: (0484) 4031400

Hyderabad

GE India Industrial Pvt. Ltd.5-2-45, Hyderbasti, RP RoadNear Gujarati High SchoolSecunderabad-500003Ph: (040) 27543162, 66311264Fax: (040) 66339272

1106

/MO

DG

LMC

B

Page 2: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

GE Energy - Industrial Solutions, India offers innovative

solutions to meet customer needs in Power & Protection.

The company has a pan India presence, with 4 regional

offices, 9 branch offices and one manufacturing plant .

GE Energy, offers solutions to customers in several segments

that include power sector, core infrastructure like marine

establishments, airports, highways, heavy & light industries,

IT & ITES infrastructure, healthcare, commercial and

residential segments.Warranty Policy :

Product offered by us are warranted against defects arising out of manufacturing processes or use of defective raw materials, for a period of 18 months from the date of supply or 12 months from the date of installation whichever is earlier. The company reserves the right to either replace or repair the defective items after ascertaining the facts through a detailed service report on usage of our products in normal conditions. However, MCB warranty is 3 years as standard and extends to 5 years in case used in GE make standard distribution boards.

The prices mentioned in the buylog for the same are for guidance purposes only. The products may be sold at lower prices also. Goods are always sold subject to laws, rules and regulations relating to excise, customs and maximum retail price as applicable at the time of purchase and as printed on the goods. Excise duty is not applicable on Guardline MCB, however applicable on RCCBs and DBs.

About GE Energy - Industrial Solutions

Page 3: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

GE Energy - Industrial Solutions, India offers innovative

solutions to meet customer needs in Power & Protection.

The company has a pan India presence, with 4 regional

offices, 9 branch offices and one manufacturing plant .

GE Energy, offers solutions to customers in several segments

that include power sector, core infrastructure like marine

establishments, airports, highways, heavy & light industries,

IT & ITES infrastructure, healthcare, commercial and

residential segments.Warranty Policy :

Product offered by us are warranted against defects arising out of manufacturing processes or use of defective raw materials, for a period of 18 months from the date of supply or 12 months from the date of installation whichever is earlier. The company reserves the right to either replace or repair the defective items after ascertaining the facts through a detailed service report on usage of our products in normal conditions. However, MCB warranty is 3 years as standard and extends to 5 years in case used in GE make standard distribution boards.

The prices mentioned in the buylog for the same are for guidance purposes only. The products may be sold at lower prices also. Goods are always sold subject to laws, rules and regulations relating to excise, customs and maximum retail price as applicable at the time of purchase and as printed on the goods. Excise duty is not applicable on Guardline MCB, however applicable on RCCBs and DBs.

About GE Energy - Industrial Solutions

Page 4: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

Contents

GuardlineMiniature Circuit Breakers

SafetripResidual Current Circuit Breakers

SafelineDistribution Boards

Dimensions & Diagrams

A6

B10

C14

Page 5: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

Contents

GuardlineMiniature Circuit Breakers

SafetripResidual Current Circuit Breakers

SafelineDistribution Boards

Dimensions & Diagrams

A6

B10

C14

Page 6: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

A7

Conforms to IS8828:96/IEC60898-1

0.5A to 63A, 10kA

Trip free mechanism

Disconnection with positive contact

Low watt loss – Energy saving

Touch proof terminals – IP20

High grade engineering plastic housing

ON-OFF flag indication

Captive terminal screws

Compatibility with all DBs

Rated Current(In) : 0.5A, 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A

Number of Poles : 1 Pole, 2 Pole, 3 Pole and 4 Pole

Breaking Capacity : 10kA

Rated Voltage : 240/415V AC

Insulation Voltage : 500V AC

Frequency : 50/60Hz

Tripping Characteristics* : C, D

Operating Temp Range : -250C to +550C

Mounting Arrangement : Snap on fixing, 35mm DIN Channel

Isolators : 40/63A in 2 Pole, 3 Pole and 4 Pole Higher ratings on request

*B series on request

Tripping Characterstics CurveType - B, C & D

Lower Limit as per Standard

Upper Limit as per Standard

Reference Calibration Temp. 40 Co

IS: 8828-1996/IEC-60898-1-2002Limit Specified in

In : Rated Current

D Type - 0.5A to 63A

B Type - 0.5A to 63AC Type - 0.5A to 63A

1

Multiple of Rated Current

1.13 1.45 2 2.55 3 5 10 14 20 28 50

-B-Type- -C-Type- -D-Type-

Tim

e in

Sec

onds

1000

1000050003600

100

10

1

0.1

0.01

Salient Features Technical DetailsGuardlineMiniature Circuit Breakers

Keeping you guarded

Page 7: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

A7

Conforms to IS8828:96/IEC60898-1

0.5A to 63A, 10kA

Trip free mechanism

Disconnection with positive contact

Low watt loss – Energy saving

Touch proof terminals – IP20

High grade engineering plastic housing

ON-OFF flag indication

Captive terminal screws

Compatibility with all DBs

Rated Current(In) : 0.5A, 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A

Number of Poles : 1 Pole, 2 Pole, 3 Pole and 4 Pole

Breaking Capacity : 10kA

Rated Voltage : 240/415V AC

Insulation Voltage : 500V AC

Frequency : 50/60Hz

Tripping Characteristics* : C, D

Operating Temp Range : -250C to +550C

Mounting Arrangement : Snap on fixing, 35mm DIN Channel

Isolators : 40/63A in 2 Pole, 3 Pole and 4 Pole Higher ratings on request

*B series on request

Tripping Characterstics CurveType - B, C & D

Lower Limit as per Standard

Upper Limit as per Standard

Reference Calibration Temp. 40 Co

IS: 8828-1996/IEC-60898-1-2002Limit Specified in

In : Rated Current

D Type - 0.5A to 63A

B Type - 0.5A to 63AC Type - 0.5A to 63A

1

Multiple of Rated Current

1.13 1.45 2 2.55 3 5 10 14 20 28 50

-B-Type- -C-Type- -D-Type-

Tim

e in

Sec

onds

1000

1000050003600

100

10

1

0.1

0.01

Salient Features Technical DetailsGuardlineMiniature Circuit Breakers

Keeping you guarded

Page 8: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

Single Pole0.5

1

2

3

4

6

10

16

20

25

32

40

50

63

Double Pole0.5

1

2

3

4

6

10

16

20

25

32

40

50

63

Triple Pole0.5

1

2

3

GLCSP00

GLCSP01

GLCSP02

GLCSP03

GLCSP04

GLCSP06

GLCSP10

GLCSP16

GLCSP20

GLCSP25

GLCSP32

GLCSP40

GLCSP50

GLCSP63

GLCDP00

GLCDP01

GLCDP02

GLCDP03

GLCDP04

GLCDP06

GLCDP10

GLCDP16

GLCDP20

GLCDP25

GLCDP32

GLCDP40

GLCDP50

GLCDP63

GLCTP00

GLCTP01

GLCTP02

GLCTP03

GLDSP00

GLDSP01

GLDSP02

GLDSP03

GLDSP04

GLDSP06

GLDSP10

GLDSP16

GLDSP20

GLDSP25

GLDSP32

GLDSP40

GLDSP50

GLDSP63

GLDDP00

GLDDP01

GLDDP02

GLDDP03

GLDDP04

GLDDP06

GLDDP10

GLDDP16

GLDDP20

GLDDP25

GLDDP32

GLDDP40

GLDDP50

GLDDP63

GLDTP00

GLDTP01

GLDTP02

GLDTP03

12

12

12

12

12

12

12

12

12

12

12

12

12

12

6

6

6

6

6

6

6

6

6

6

6

6

6

6

4

4

4

4

Guardline Ordering CodesCurrent Rating

(A)Ordering Cat.No.

Type COrdering Cat.No.

Type DStandard Pack Qty

Current Rating(A)

Ordering Cat.No. Type C

Ordering Cat.No. Type D

Standard Pack Qty

Current Rating

For marked MCBs please contact your nearest GE sales office

Poles

40 Double Pole GLISDP40

63 Double Pole GLISDP63

40 Triple Pole GLISTP40

63 Triple Pole GLISTP63

40 Four Pole GLISFP40

63 Four Pole GLISFP63

GLCTP04

GLCTP06

GLCTP10

GLCTP16

GLCTP20

GLCTP25

GLCTP32

GLCTP40

GLCTP50

GLCTP63

GLCFP00

GLCFP01

GLCFP02

GLCFP03

GLCFP04

GLCFP06

GLCFP10

GLCFP16

GLCFP20

GLCFP25

GLCFP32

GLCFP40

GLCFP50

GLCFP63

GLDTP04

GLDTP06

GLDTP10

GLDTP16

GLDTP20

GLDTP25

GLDTP32

GLDTP40

GLDTP50

GLDTP63

GLDFP00

GLDFP01

GLDFP02

GLDFP03

GLDFP04

GLDFP06

GLDFP10

GLDFP16

GLDFP20

GLDFP25

GLDFP32

GLDFP40

GLDFP50

GLDFP63

4

4

4

4

4

4

4

4

4

4

3

3

3

3

3

3

3

3

3

3

3

3

3

3

A9A8

Isolator

4

6

10

16

20

25

32

40

50

63

Four Pole0.5

1

2

3

4

6

10

16

20

25

32

40

50

63

Ordering Cat.No.

Page 9: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

Single Pole0.5

1

2

3

4

6

10

16

20

25

32

40

50

63

Double Pole0.5

1

2

3

4

6

10

16

20

25

32

40

50

63

Triple Pole0.5

1

2

3

GLCSP00

GLCSP01

GLCSP02

GLCSP03

GLCSP04

GLCSP06

GLCSP10

GLCSP16

GLCSP20

GLCSP25

GLCSP32

GLCSP40

GLCSP50

GLCSP63

GLCDP00

GLCDP01

GLCDP02

GLCDP03

GLCDP04

GLCDP06

GLCDP10

GLCDP16

GLCDP20

GLCDP25

GLCDP32

GLCDP40

GLCDP50

GLCDP63

GLCTP00

GLCTP01

GLCTP02

GLCTP03

GLDSP00

GLDSP01

GLDSP02

GLDSP03

GLDSP04

GLDSP06

GLDSP10

GLDSP16

GLDSP20

GLDSP25

GLDSP32

GLDSP40

GLDSP50

GLDSP63

GLDDP00

GLDDP01

GLDDP02

GLDDP03

GLDDP04

GLDDP06

GLDDP10

GLDDP16

GLDDP20

GLDDP25

GLDDP32

GLDDP40

GLDDP50

GLDDP63

GLDTP00

GLDTP01

GLDTP02

GLDTP03

12

12

12

12

12

12

12

12

12

12

12

12

12

12

6

6

6

6

6

6

6

6

6

6

6

6

6

6

4

4

4

4

Guardline Ordering CodesCurrent Rating

(A)Ordering Cat.No.

Type COrdering Cat.No.

Type DStandard Pack Qty

Current Rating(A)

Ordering Cat.No. Type C

Ordering Cat.No. Type D

Standard Pack Qty

Current Rating

For marked MCBs please contact your nearest GE sales office

Poles

40 Double Pole GLISDP40

63 Double Pole GLISDP63

40 Triple Pole GLISTP40

63 Triple Pole GLISTP63

40 Four Pole GLISFP40

63 Four Pole GLISFP63

GLCTP04

GLCTP06

GLCTP10

GLCTP16

GLCTP20

GLCTP25

GLCTP32

GLCTP40

GLCTP50

GLCTP63

GLCFP00

GLCFP01

GLCFP02

GLCFP03

GLCFP04

GLCFP06

GLCFP10

GLCFP16

GLCFP20

GLCFP25

GLCFP32

GLCFP40

GLCFP50

GLCFP63

GLDTP04

GLDTP06

GLDTP10

GLDTP16

GLDTP20

GLDTP25

GLDTP32

GLDTP40

GLDTP50

GLDTP63

GLDFP00

GLDFP01

GLDFP02

GLDFP03

GLDFP04

GLDFP06

GLDFP10

GLDFP16

GLDFP20

GLDFP25

GLDFP32

GLDFP40

GLDFP50

GLDFP63

4

4

4

4

4

4

4

4

4

4

3

3

3

3

3

3

3

3

3

3

3

3

3

3

A9A8

Isolator

4

6

10

16

20

25

32

40

50

63

Four Pole0.5

1

2

3

4

6

10

16

20

25

32

40

50

63

Ordering Cat.No.

Page 10: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

B11

Personal protection - Against electrocutionThe use of exposed, substandard and poorly wired, or damaged equipment reduces the safety of an installation and increases the risk of an electric shock to the person in contact. Electrocution is a passage of current flowing through human body which affects the vital functioning like breathing and heartbeat. This can be very dangerous to the person in contact depending upon current and time for which it flows.

A correctly selected RCCB can detect even small currents flowing to earth and reduces the risk of electrocution. The effect of electric current through human body has been well researched and is as below.

500mA Immediate cardiac arrest resulting in death

70-100mA Cardiac fibrillation; the heart begins to

vibrate and no longer beats at a steady rate

This situation is dangerous since it is

irreversible

20-30mA Muscle contraction can cause respiratory

paralysis 10mA Muscle contraction: the person remains “stuck” to the conductor

1-10mA Prickling sensations

Salient Features Technical Details

Conforms to IEC61008-1

2 Pole & 4 Pole

Trip free mechanism

Disconnection with positive contact

Antiwelding contacts

Bi-connect facility

Touch proof terminals – IP20

Resistance against unwanted tripping

Test facility - A test button ‘T’ provided on device

No ageing effect

Compatibility with all DBs

Protection

Rated Current(In) : 25A, 40A, 63A

Sensitivity* : 30mA, 100mA, 300mA

Number of Poles : 2 Pole and 4 Pole

Rated Voltage : 240/415V AC

Insulation Voltage : 500V AC

Frequency : 50/60Hz

Operating Temp. Range : -250C to +600C

Terminal Capacity : 25mm2

Mounting Arrangement : 35mm DIN Channel

Service Life : 20000 operations

Optional Accessories : Aux. contact, shunt & undervoltage release, motor operator & panel board switch

SafetripResidual Current Circuit Breakers

Keeping you safe

*500mA sensitivity available on request for industrial applications

Page 11: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

B11

Personal protection - Against electrocutionThe use of exposed, substandard and poorly wired, or damaged equipment reduces the safety of an installation and increases the risk of an electric shock to the person in contact. Electrocution is a passage of current flowing through human body which affects the vital functioning like breathing and heartbeat. This can be very dangerous to the person in contact depending upon current and time for which it flows.

A correctly selected RCCB can detect even small currents flowing to earth and reduces the risk of electrocution. The effect of electric current through human body has been well researched and is as below.

500mA Immediate cardiac arrest resulting in death

70-100mA Cardiac fibrillation; the heart begins to

vibrate and no longer beats at a steady rate

This situation is dangerous since it is

irreversible

20-30mA Muscle contraction can cause respiratory

paralysis 10mA Muscle contraction: the person remains “stuck” to the conductor

1-10mA Prickling sensations

Salient Features Technical Details

Conforms to IEC61008-1

2 Pole & 4 Pole

Trip free mechanism

Disconnection with positive contact

Antiwelding contacts

Bi-connect facility

Touch proof terminals – IP20

Resistance against unwanted tripping

Test facility - A test button ‘T’ provided on device

No ageing effect

Compatibility with all DBs

Protection

Rated Current(In) : 25A, 40A, 63A

Sensitivity* : 30mA, 100mA, 300mA

Number of Poles : 2 Pole and 4 Pole

Rated Voltage : 240/415V AC

Insulation Voltage : 500V AC

Frequency : 50/60Hz

Operating Temp. Range : -250C to +600C

Terminal Capacity : 25mm2

Mounting Arrangement : 35mm DIN Channel

Service Life : 20000 operations

Optional Accessories : Aux. contact, shunt & undervoltage release, motor operator & panel board switch

SafetripResidual Current Circuit Breakers

Keeping you safe

*500mA sensitivity available on request for industrial applications

Page 12: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

B13B12

1 Usually has no reactions or effects.

2 Usually has no harmful effects.

3 Usually, no organic damage is expected.

Here the likelihood present is of muscular contractions

and difficulty in breathing. Reversible disturbances in

the formation and conductance of impulses in the

heart, including arterial fibrillation and transient

cardiac arrest without ventricular fibrillation are

possible. These effects increase with current

magnitude and time.

4 In addition to the effects of Zone 3, the probability of

ventricular fibrillation increases from 5% (curve c2),

to about 50% (curve c3) and beyond 50% above

(curve c3). Increasing with magnitude and time are

pathophysiological effects as cardiac and breathing

arrest, whilst heavy burns are possible.

However, electrocution should not be viewed in terms of “current” alone but in terms of “contact voltage”. A person gets electrocuted by coming in contact with an object that has a different potential from his/her own. The difference in potential causes the current to flow through the body.

The human body has known limits:

In a dry environment, voltage limit = 50V

In a humid environment, voltage limit = 25V

Over current protection devices like MCB are unable to act

promptly on small earth leakage currents. To comply with wiring

regulations the earth fault loop impedance in Ohms, multiplied

by the rated tripping current of the RCD in amperes must not

exceed 50.

Against Indirect Contact Zone Physiological effects

The majority of fires in an electrical installation are result of

leakage current flowing to earth and even a current of the order

of 1A can lead to big fire. These type of faults are not detected by

the normal short circuit protection device like MCB or Fuse. A

correctly selected RCCB will detect this leakage and save the risk

of fire saving the installation.

Against Fire

Selection

30mA - This RCCB will provide a high degree of protection against

electrocution. The current flowing through human body depends

upon the resistance of human body and voltage across it and can

vary between 80mA to 240mA. To be within zone of the IEC curve

as shown in chart. It is necessary for the RCCB to operate within

50ms at 240mA and 150ms at 80mA. Both these conditions are

satisfied by 30mA RCCB. For households, individual loads, damp

areas and construction installations, RCCB with sensitivity not

exceeding 30mA is recommended.

100mA - This RCCB will normally give high degree of protection

against electrocution but there is a possibility that the shock

current could fall below the tripping level of RCCB. This could occur

if additional resistances to that of human body are included in the

earth path. The 100mA RCCB protects against leakage currents

and indirect contact with earth loop impedance upto 500 Ohms.

300mA - This RCCB may be used where only fire protection is

required. eg., on lighting circuits and larger installations. These will

not give any protection against electrocution.

Amps Poles Sensitivity (mA) Sensitivity (mA)

Rating at 240V/415V AC Rating at 240V AC

Safetrip RCCB offering

Poles

25

40

63

25

40

63

25

40

63

4

4

4

4

4

4

4

4

4

30

30

30

100

100

100

300

300

300

2

2

2

2

2

2

2

2

2

30

30

30

100

100

100

300

300

300

Page 13: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

B13B12

1 Usually has no reactions or effects.

2 Usually has no harmful effects.

3 Usually, no organic damage is expected.

Here the likelihood present is of muscular contractions

and difficulty in breathing. Reversible disturbances in

the formation and conductance of impulses in the

heart, including arterial fibrillation and transient

cardiac arrest without ventricular fibrillation are

possible. These effects increase with current

magnitude and time.

4 In addition to the effects of Zone 3, the probability of

ventricular fibrillation increases from 5% (curve c2),

to about 50% (curve c3) and beyond 50% above

(curve c3). Increasing with magnitude and time are

pathophysiological effects as cardiac and breathing

arrest, whilst heavy burns are possible.

However, electrocution should not be viewed in terms of “current” alone but in terms of “contact voltage”. A person gets electrocuted by coming in contact with an object that has a different potential from his/her own. The difference in potential causes the current to flow through the body.

The human body has known limits:

In a dry environment, voltage limit = 50V

In a humid environment, voltage limit = 25V

Over current protection devices like MCB are unable to act

promptly on small earth leakage currents. To comply with wiring

regulations the earth fault loop impedance in Ohms, multiplied

by the rated tripping current of the RCD in amperes must not

exceed 50.

Against Indirect Contact Zone Physiological effects

The majority of fires in an electrical installation are result of

leakage current flowing to earth and even a current of the order

of 1A can lead to big fire. These type of faults are not detected by

the normal short circuit protection device like MCB or Fuse. A

correctly selected RCCB will detect this leakage and save the risk

of fire saving the installation.

Against Fire

Selection

30mA - This RCCB will provide a high degree of protection against

electrocution. The current flowing through human body depends

upon the resistance of human body and voltage across it and can

vary between 80mA to 240mA. To be within zone of the IEC curve

as shown in chart. It is necessary for the RCCB to operate within

50ms at 240mA and 150ms at 80mA. Both these conditions are

satisfied by 30mA RCCB. For households, individual loads, damp

areas and construction installations, RCCB with sensitivity not

exceeding 30mA is recommended.

100mA - This RCCB will normally give high degree of protection

against electrocution but there is a possibility that the shock

current could fall below the tripping level of RCCB. This could occur

if additional resistances to that of human body are included in the

earth path. The 100mA RCCB protects against leakage currents

and indirect contact with earth loop impedance upto 500 Ohms.

300mA - This RCCB may be used where only fire protection is

required. eg., on lighting circuits and larger installations. These will

not give any protection against electrocution.

Amps Poles Sensitivity (mA) Sensitivity (mA)

Rating at 240V/415V AC Rating at 240V AC

Safetrip RCCB offering

Poles

25

40

63

25

40

63

25

40

63

4

4

4

4

4

4

4

4

4

30

30

30

100

100

100

300

300

300

2

2

2

2

2

2

2

2

2

30

30

30

100

100

100

300

300

300

Page 14: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

C15

Aesthetically designed in compliance with latest standards

Wide range-sheet steel DBs upto 18 ways

SPN, TPN in single & double door

Degree of protection IP30, IP42 & IP43

Surface & flush mounting

Powder coated – Corrosion & scratch resistance

Detachable gland plate

Adequate knock-outs on all sides

Generous wiring space

Clear circuit identification

Supplied complete with bus bars, earth & neutral bars

Multitier, phase segregated, 7 segments, vertical DBs

Plug & sockets boards

Prewired DBs available on request – Please contact your nearest GE Sales Office

Voltage : 240V AC for SPN, 415V for TP/TPN DBs

Standard Busbar Rating : 63A/100A/125A

No. of Ways : 4, 6, 8, 10, 12, 14, 18 ways

Mounting : Surface/Flush

Dielectric Strength : 2.5kV RMS AC for 1min

Mounting Arrangement : 35mm DIN Rail for MCBs, RCCBs

Salient Features Technical DetailsSafelineDistribution Boards

Keeping you secure

Page 15: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

C15

Aesthetically designed in compliance with latest standards

Wide range-sheet steel DBs upto 18 ways

SPN, TPN in single & double door

Degree of protection IP30, IP42 & IP43

Surface & flush mounting

Powder coated – Corrosion & scratch resistance

Detachable gland plate

Adequate knock-outs on all sides

Generous wiring space

Clear circuit identification

Supplied complete with bus bars, earth & neutral bars

Multitier, phase segregated, 7 segments, vertical DBs

Plug & sockets boards

Prewired DBs available on request – Please contact your nearest GE Sales Office

Voltage : 240V AC for SPN, 415V for TP/TPN DBs

Standard Busbar Rating : 63A/100A/125A

No. of Ways : 4, 6, 8, 10, 12, 14, 18 ways

Mounting : Surface/Flush

Dielectric Strength : 2.5kV RMS AC for 1min

Mounting Arrangement : 35mm DIN Rail for MCBs, RCCBs

Salient Features Technical DetailsSafelineDistribution Boards

Keeping you secure

Page 16: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

C17C16

Safe line - Sheet steel - SPN

SPN version in 4, 6, 8, 10, 12, 14, 16 and 18 ways outgoing

Single door, double door and acrylic door

IP30, IP42 and IP43 protection

Liberal wiring space, adequate cable glands

Superior powder coated finish for better protection against heat & dust (Powder coating thickness of more than 60 microns)

Detachable gland plates

Complete with phase busbars, earthbars, neutral bars & cable kit

Salient Features

Technical Details

DescriptionCode Ref. Code Ref. Code Ref.

Single Door Double Door Acrylic Door

Dimensions

Plane enclosures

1, 2, 3, 4, 5, 6, 8 ways

IP30 pole incomer

Salient Features

4Way SLSMS0204Y SLSMD0204Y 6Way SLSMS0206Y SLSMD0206Y SLSMA0206Y 8Way SLSMS0208Y SLSMD0208Y SLSMA0208Y 10Way SLSMS0210Y SLSMD0210Y SLSMA0210Y 12Way SLSMS0212Y SLSMD0212Y SLSMA0212Y 14Way SLSMS0214Y SLSMD0214Y SLSMA0214Y 16Way SLSMS0216Y SLSMD0216Y SLSMA0216Y 18Way SLSMS0218Y SLSMD0218Y SLSMA0218Y0

Technical Details

DescriptionCode Ref.

Single Door

1Way SLEMS0001Y 2Way SLEMS0002Y 3Way SLEMS0003Y 4Way SLEMS0004Y 6Way SLEMS0006Y 8Way SLEMS0008Y Blanking Plate 1Way SLMBP0001X

Dimensions & Diagram - 1.1 | Page D28One Way Enclosures

Dimensions & Diagram - 1.2 | Page D28SPN Distribution Boards

One Way Enclosures SPN Distribution Boards

Page 17: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

C17C16

Safe line - Sheet steel - SPN

SPN version in 4, 6, 8, 10, 12, 14, 16 and 18 ways outgoing

Single door, double door and acrylic door

IP30, IP42 and IP43 protection

Liberal wiring space, adequate cable glands

Superior powder coated finish for better protection against heat & dust (Powder coating thickness of more than 60 microns)

Detachable gland plates

Complete with phase busbars, earthbars, neutral bars & cable kit

Salient Features

Technical Details

DescriptionCode Ref. Code Ref. Code Ref.

Single Door Double Door Acrylic Door

Dimensions

Plane enclosures

1, 2, 3, 4, 5, 6, 8 ways

IP30 pole incomer

Salient Features

4Way SLSMS0204Y SLSMD0204Y 6Way SLSMS0206Y SLSMD0206Y SLSMA0206Y 8Way SLSMS0208Y SLSMD0208Y SLSMA0208Y 10Way SLSMS0210Y SLSMD0210Y SLSMA0210Y 12Way SLSMS0212Y SLSMD0212Y SLSMA0212Y 14Way SLSMS0214Y SLSMD0214Y SLSMA0214Y 16Way SLSMS0216Y SLSMD0216Y SLSMA0216Y 18Way SLSMS0218Y SLSMD0218Y SLSMA0218Y0

Technical Details

DescriptionCode Ref.

Single Door

1Way SLEMS0001Y 2Way SLEMS0002Y 3Way SLEMS0003Y 4Way SLEMS0004Y 6Way SLEMS0006Y 8Way SLEMS0008Y Blanking Plate 1Way SLMBP0001X

Dimensions & Diagram - 1.1 | Page D28One Way Enclosures

Dimensions & Diagram - 1.2 | Page D28SPN Distribution Boards

One Way Enclosures SPN Distribution Boards

Page 18: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

C19C18

4, 6, 8 and 12 ways

Single door, double door and acrylic door (IP30, IP42 and IP43)

With provision 8 module incomer and SP MCB as outgoing

With copper busbar, neutral link, earth link

Supplied with wire set

Salient Features

Technical Details

DescriptionCode Ref. Code Ref. Code Ref.

Single Door Double Door

4Way SLTMS0804Y SLTMD0804Y SLTMA0804Y 6Way SLTMS0806Y SLTMD0806Y SLTMA0806Y 8Way SLTMS0808Y SLTMD0808Y SLTMA0808Y 12Way SLTMS0812Y SLTMD0812Y SLTMA0812Y

Acrylic Door

Dimensions & Diagram - 1.3 | Page D28TPN Distribution Boards

Suitable for flush mounting and surface mounting

IP30, IP42 and IP43 protection

Detachable gland plates

With copper bus bar

Suitable for 8 module incomer and DP RCCB/RCBO as sub incomer and SP MCBs as outgoing

3 separate mutual link for each phase

With neutral link and earth bar

6, 8, 12, 16 ways

Salient Features

Technical Details : With four neutral links, one earth link, excluding bus bars and interconnections

DescriptionCode Ref. Code Ref.

Single Door Double Door

6Way 8+4+2 SLHMS0806Y SLHMD0806Y 8Way 8+6+2 SLHMS0808Y SLHMD0808Y 12Way 8+10+2 SLHMS0812Y SLHMD0812Y 16Way 8+14+2 SLHMS0816Y SLHMD0816Y

Dimensions & Diagram - 1.4 | Page D28Per Phase Isolation Horizontal Distribution Boards

TPN Distribution Boards Per Phase IsolationHorizontal Distribution Boards

Page 19: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

C19C18

4, 6, 8 and 12 ways

Single door, double door and acrylic door (IP30, IP42 and IP43)

With provision 8 module incomer and SP MCB as outgoing

With copper busbar, neutral link, earth link

Supplied with wire set

Salient Features

Technical Details

DescriptionCode Ref. Code Ref. Code Ref.

Single Door Double Door

4Way SLTMS0804Y SLTMD0804Y SLTMA0804Y 6Way SLTMS0806Y SLTMD0806Y SLTMA0806Y 8Way SLTMS0808Y SLTMD0808Y SLTMA0808Y 12Way SLTMS0812Y SLTMD0812Y SLTMA0812Y

Acrylic Door

Dimensions & Diagram - 1.3 | Page D28TPN Distribution Boards

Suitable for flush mounting and surface mounting

IP30, IP42 and IP43 protection

Detachable gland plates

With copper bus bar

Suitable for 8 module incomer and DP RCCB/RCBO as sub incomer and SP MCBs as outgoing

3 separate mutual link for each phase

With neutral link and earth bar

6, 8, 12, 16 ways

Salient Features

Technical Details : With four neutral links, one earth link, excluding bus bars and interconnections

DescriptionCode Ref. Code Ref.

Single Door Double Door

6Way 8+4+2 SLHMS0806Y SLHMD0806Y 8Way 8+6+2 SLHMS0808Y SLHMD0808Y 12Way 8+10+2 SLHMS0812Y SLHMD0812Y 16Way 8+14+2 SLHMS0816Y SLHMD0816Y

Dimensions & Diagram - 1.4 | Page D28Per Phase Isolation Horizontal Distribution Boards

TPN Distribution Boards Per Phase IsolationHorizontal Distribution Boards

Page 20: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

IP30, IP42 and IP43 protection

With 8 cutting incomer and 3 rows with different configuration

Separate neutral for each phase

SP and TP outgoing are possible

Sub incomer of 2 Pole

Salient Features

Single Door

Technical Details :With four neutral links, one earth link, excluding bus bars and interconnections.

DescriptionCode Ref. Code Ref.

Double Door Acrylic Door

8 Way (3 Rowx8+1 Rowx8) SLIMD0808Y SLIMA0808Y 10 Way (3 Rowx10+1 Rowx8) SLIMD0810Y SLIMA0810Y 12 Way (3 Rowx12+1 Rowx8) SLIMD0812Y SLIMA0812Y 14 Way (3 Rowx14+1 Rowx8) SLIMD0814Y SLIMA0814Y 16 Way (3 Rowx16+1 Rowx8) SLIMD0816Y SLIMA0816Y

Dimensions & Diagram - 1.5 | Page D29Per Phase Isolation Vertical Distribution Boards

IP30, IP42 and IP43 protection

With MCB and 49 RCCB incomer (4 Pole)

TP and SP outgoing

IP30 and IP43

With copper bus bar

Spectra range MCCB upto 125A and Record range for higher rating

Salient Features

Technical Details - Provision for 4Pole MCB/RCCB

DescriptionCode Ref. Code Ref. Code Ref.

Single Door Double Door Acrylic Door

4Way SLVMS0804Y SLVMD0804Y SLVMA0804Y 6Way SLVMS0806Y SLVMD0806Y SLVMA0806Y 8Way SLVMS0808Y SLVMD0808Y SLVMA0808Y 12Way SLVMS0812Y SLVMD0812Y SLVMA0812Y

Dimensions & Diagram - 1.6 | Page D29TPN Vertical Distribution Boards

C21C20

Per Phase IsolationVertical Distribution Boards TPN Vertical Distribution Boards

Page 21: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

IP30, IP42 and IP43 protection

With 8 cutting incomer and 3 rows with different configuration

Separate neutral for each phase

SP and TP outgoing are possible

Sub incomer of 2 Pole

Salient Features

Single Door

Technical Details :With four neutral links, one earth link, excluding bus bars and interconnections.

DescriptionCode Ref. Code Ref.

Double Door Acrylic Door

8 Way (3 Rowx8+1 Rowx8) SLIMD0808Y SLIMA0808Y 10 Way (3 Rowx10+1 Rowx8) SLIMD0810Y SLIMA0810Y 12 Way (3 Rowx12+1 Rowx8) SLIMD0812Y SLIMA0812Y 14 Way (3 Rowx14+1 Rowx8) SLIMD0814Y SLIMA0814Y 16 Way (3 Rowx16+1 Rowx8) SLIMD0816Y SLIMA0816Y

Dimensions & Diagram - 1.5 | Page D29Per Phase Isolation Vertical Distribution Boards

IP30, IP42 and IP43 protection

With MCB and 49 RCCB incomer (4 Pole)

TP and SP outgoing

IP30 and IP43

With copper bus bar

Spectra range MCCB upto 125A and Record range for higher rating

Salient Features

Technical Details - Provision for 4Pole MCB/RCCB

DescriptionCode Ref. Code Ref. Code Ref.

Single Door Double Door Acrylic Door

4Way SLVMS0804Y SLVMD0804Y SLVMA0804Y 6Way SLVMS0806Y SLVMD0806Y SLVMA0806Y 8Way SLVMS0808Y SLVMD0808Y SLVMA0808Y 12Way SLVMS0812Y SLVMD0812Y SLVMA0812Y

Dimensions & Diagram - 1.6 | Page D29TPN Vertical Distribution Boards

C21C20

Per Phase IsolationVertical Distribution Boards TPN Vertical Distribution Boards

Page 22: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

C23C22

Suitable for flush mounting and surface mounting

IP30, IP42 and IP43 protection

Detachable gland plates

With copper bus bar

With neutral bar and earth bar

Pan assembly for ease of installation

With provisions for Spectra / Record Range MCCB as incomer and SP/TP MCBs as outgoing

4, 6, 8 and 12 ways

Salient Features

Technical Details - Provision for 4Pole MCB/RCCB

DescriptionCode Ref. Code Ref.

Double Door - 100A Double Door - 225A

4Way SLVMDM04Y SLVMDM204Y 6Way SLVMDM06Y SLVMDM206Y 8Way SLVMDM08Y SLVMDM208Y 12Way SLVMDM12Y SLVMDM212Y

Dimensions & Diagram - 1.7 | Page D29TPN Vertical Distribution Boards with MCCB Incomer

With provision for 3nos. phase selector switches and in-built piano switches

Suitable for flush mounting and surface mounting

IP30, IP42 and IP43 protection

Detachable gland plates

With copper bus bar

With neutral bar, earth bar, and wire set

With provision for 8 module incomer and SP MCB, as outgoing

4, 6, 8 and 12 ways

Salient Features

Technical Details - TPN phase selector DB with 3nos. piano switch

DescriptionCode Ref. Code Ref.

Single Door Double Door

4Way SLXMS0804Y SLXMD0804Y 6Way SLXMS0806Y SLXMD0806Y 8Way SLXMS0808Y SLXMD0808Y 12Way SLXMS0812Y SLXMD0812Y

Dimensions & Diagram - 1.8 | Page D29Phase Selector Distribution Boards

TPN Vertical Distribution Boards with MCCB Incomer

Phase Selector Distribution Boards

Page 23: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

C23C22

Suitable for flush mounting and surface mounting

IP30, IP42 and IP43 protection

Detachable gland plates

With copper bus bar

With neutral bar and earth bar

Pan assembly for ease of installation

With provisions for Spectra / Record Range MCCB as incomer and SP/TP MCBs as outgoing

4, 6, 8 and 12 ways

Salient Features

Technical Details - Provision for 4Pole MCB/RCCB

DescriptionCode Ref. Code Ref.

Double Door - 100A Double Door - 225A

4Way SLVMDM04Y SLVMDM204Y 6Way SLVMDM06Y SLVMDM206Y 8Way SLVMDM08Y SLVMDM208Y 12Way SLVMDM12Y SLVMDM212Y

Dimensions & Diagram - 1.7 | Page D29TPN Vertical Distribution Boards with MCCB Incomer

With provision for 3nos. phase selector switches and in-built piano switches

Suitable for flush mounting and surface mounting

IP30, IP42 and IP43 protection

Detachable gland plates

With copper bus bar

With neutral bar, earth bar, and wire set

With provision for 8 module incomer and SP MCB, as outgoing

4, 6, 8 and 12 ways

Salient Features

Technical Details - TPN phase selector DB with 3nos. piano switch

DescriptionCode Ref. Code Ref.

Single Door Double Door

4Way SLXMS0804Y SLXMD0804Y 6Way SLXMS0806Y SLXMD0806Y 8Way SLXMS0808Y SLXMD0808Y 12Way SLXMS0812Y SLXMD0812Y

Dimensions & Diagram - 1.8 | Page D29Phase Selector Distribution Boards

TPN Vertical Distribution Boards with MCCB Incomer

Phase Selector Distribution Boards

Page 24: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

DB with phase segregation and separator between incomer and outgoing

Suitable for flush mounting and surface mounting

IP30, IP42 and IP43 protection

Detachable gland plates

With copper bus bar

With neutral bar, earth bar

With provision for 8 module incomer and DP RCCB/RCBO as sub incomer and SP MCB, as outgoing

4, 6, 8 and 12 ways

Suitable for flush mounting and surface mounting

IP30, IP42 and IP43 protection

Detachable gland plates

Flexibility to organize the distribution as per site requirements

With neutral bar and earth bar

26, 28, 39, 42, 52, 56 ways in 2, 3 and 4 rows

Other configurations on request

Salient Features

C25C24

Technical Details - Compartmental space for 4P MCB

DescriptionCode Ref. Code Ref.

Single Door Double Door

4Way SLCMS0804Y SLCMD0804Y 6Way SLCMS0806Y SLCMD0806Y 8Way SLCMS0808Y SLCMD0808Y 12Way SLCMS0812Y SLCMD0812Y

Dimensions & Diagram - 1.9 | Page D30Phase Segregated Distribution Boards

Salient Features

Technical Details

DescriptionCode Ref. Code Ref.

Double Door Acrylic Door

13module x 2 tier SLFMD0213Y SLFMA0213Y 13module x 3 tier SLFMD0313Y SLFMA0313Y 13module x 4 tier SLFMD0413Y SLFMA0413Y 14module x 2 tier SLFMD0214Y SLFMA0214Y 14module x 3 tier SLFMD0314Y SLFMA0314Y 14module x 4 tier SLFMD0414Y SLFMA0414Y

Dimensions & Diagram - 1.10 | Page D30Universal Distribution Boards

Phase Segregated Distribution Boards Universal Distribution Boards

Page 25: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

DB with phase segregation and separator between incomer and outgoing

Suitable for flush mounting and surface mounting

IP30, IP42 and IP43 protection

Detachable gland plates

With copper bus bar

With neutral bar, earth bar

With provision for 8 module incomer and DP RCCB/RCBO as sub incomer and SP MCB, as outgoing

4, 6, 8 and 12 ways

Suitable for flush mounting and surface mounting

IP30, IP42 and IP43 protection

Detachable gland plates

Flexibility to organize the distribution as per site requirements

With neutral bar and earth bar

26, 28, 39, 42, 52, 56 ways in 2, 3 and 4 rows

Other configurations on request

Salient Features

C25C24

Technical Details - Compartmental space for 4P MCB

DescriptionCode Ref. Code Ref.

Single Door Double Door

4Way SLCMS0804Y SLCMD0804Y 6Way SLCMS0806Y SLCMD0806Y 8Way SLCMS0808Y SLCMD0808Y 12Way SLCMS0812Y SLCMD0812Y

Dimensions & Diagram - 1.9 | Page D30Phase Segregated Distribution Boards

Salient Features

Technical Details

DescriptionCode Ref. Code Ref.

Double Door Acrylic Door

13module x 2 tier SLFMD0213Y SLFMA0213Y 13module x 3 tier SLFMD0313Y SLFMA0313Y 13module x 4 tier SLFMD0413Y SLFMA0413Y 14module x 2 tier SLFMD0214Y SLFMA0214Y 14module x 3 tier SLFMD0314Y SLFMA0314Y 14module x 4 tier SLFMD0414Y SLFMA0414Y

Dimensions & Diagram - 1.10 | Page D30Universal Distribution Boards

Phase Segregated Distribution Boards Universal Distribution Boards

Page 26: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

C26

SPN and TPN Distribution Boards

With in-built plug and socket

Ideal for protection of appliances like AC’s, Geysers etc.

Available from 20A SPN to 63A TPN

Available for DP RCCB incomer

Excellent aesthetics

Salient Features

Technical Details

DescriptionCode Ref.

Single Door

20A SPN SLRMS0S20Y 20A TPN SLRMS0T20Y 32A TPN SLRMS0T32Y 20A with provision for DP RCCB SLRMS0220Y 32A TP with provision for 4P RCCB SLRMS0432Y 63A TP with provision for 3P MCB SLRMS0363Y

Dimensions & Diagram - 1.11 | Page D30Plug & Socket Boards

Plug & Socket Boards

Dimensions & DiagramPlease contact your nearest GE sales office for drawings in printable format

Page 27: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

C26

SPN and TPN Distribution Boards

With in-built plug and socket

Ideal for protection of appliances like AC’s, Geysers etc.

Available from 20A SPN to 63A TPN

Available for DP RCCB incomer

Excellent aesthetics

Salient Features

Technical Details

DescriptionCode Ref.

Single Door

20A SPN SLRMS0S20Y 20A TPN SLRMS0T20Y 32A TPN SLRMS0T32Y 20A with provision for DP RCCB SLRMS0220Y 32A TP with provision for 4P RCCB SLRMS0432Y 63A TP with provision for 3P MCB SLRMS0363Y

Dimensions & Diagram - 1.11 | Page D30Plug & Socket Boards

Plug & Socket Boards

Dimensions & DiagramPlease contact your nearest GE sales office for drawings in printable format

Page 28: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

D29D28

Dimensions & Diagram - 1.1 One Way Enclosures

Dimensions & Diagram - 1.2 SPN Distribution Boards

Dimensions & Diagram - 1.4Per Phase Isolation Horizontal Distribution Boards

Dimensions & Diagram - 1.6TPN Vertical Distribution Boards

Dimensions & Diagram - 1.7TPN Vertical Distribution Boards with MCCB Incomer

Dimensions & Diagram - 1.5Per Phase Isolation Vertical Distribution Boards

Dimensions & Diagram - 1.8 Phase Selector Distribution Boards

Dimensions & Diagram - 1.3 TPN Distribution Boards

245

105

225

470

340

450

Page 29: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

D29D28

Dimensions & Diagram - 1.1 One Way Enclosures

Dimensions & Diagram - 1.2 SPN Distribution Boards

Dimensions & Diagram - 1.4Per Phase Isolation Horizontal Distribution Boards

Dimensions & Diagram - 1.6TPN Vertical Distribution Boards

Dimensions & Diagram - 1.7TPN Vertical Distribution Boards with MCCB Incomer

Dimensions & Diagram - 1.5Per Phase Isolation Vertical Distribution Boards

Dimensions & Diagram - 1.8 Phase Selector Distribution Boards

Dimensions & Diagram - 1.3 TPN Distribution Boards

245

105

225

470

340

450

Page 30: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

D30

Dimensions & Diagram - 1.9Phase Segregated Distribution Boards

Dimensions & Diagram - 1.11Plug & Socket Boards

Dimensions:

168x137x60275x135x65275x135x65235x180x65275x180x65317x140x127

Note :Product upgradation is a continuous process. The data given is subject to change without any prior notice. Please contact your nearest GE Sales office for the latest product information.

Dimensions & Diagram - 1.10Universal Distribution Boards

168

137

78

60

5

5 124

110

155

Page 31: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

D30

Dimensions & Diagram - 1.9Phase Segregated Distribution Boards

Dimensions & Diagram - 1.11Plug & Socket Boards

Dimensions:

168x137x60275x135x65275x135x65235x180x65275x180x65317x140x127

Note :Product upgradation is a continuous process. The data given is subject to change without any prior notice. Please contact your nearest GE Sales office for the latest product information.

Dimensions & Diagram - 1.10Universal Distribution Boards

168

137

78

60

5

5 124

110

155

Page 32: SOUTH Distribution System - GE · PDF fileEmail: query@ge.com Toll Free No: 18001024343 Customer Care: gecustomer.care@ge.com We are committed to continuous development and improvement

Distribution SystemMCBs, RCCBs, Distribution Boards

Keeping you protected

REGIONAL OFFICES

NORTH

BRANCH OFFICES

New Delhi

GE India Industrial Pvt. Ltd.71/1, Shivaji MargNew Delhi-110015Ph: (011) 45052277/8Fax: (011) 25928088

Chandigarh

GE India Industrial Pvt. Ltd.SCO No. 72 & 73, First FloorSector 8/C, Madhya MargChandigarh-160008Ph: (0172) 3982908-10Fax: (0172) 3982905

Jaipur

GE India Industrial Pvt. Ltd.448, 4th Floor, Ganapati PlazaM.I. Road, Jaipur-302001Ph: (0141) 5112802Fax: (0141) 2389012

Lucknow

GE India Industrial Pvt. Ltd.101, Ace Business Center19, Vidhan Sabha MargLucknow-226001Ph: (0522) 3203808, 3012444/666Fax: (0522) 4045909

SOUTH

Bangalore

GE India Industrial Pvt. Ltd.The Millenia, Level-6, Tower B1 & 2, Murphy Road, UlsoorBangalore-560008Ph: (080) 41434000Fax: (080) 41434199

Chennai

GE India Industrial Pvt. Ltd.Temple Tower, 6th Floor476, (New No. 672) Anna SalaiNandanamChennai-600035Ph: (044) 45070470-84Fax: (044) 45070474

Coimbatore

GE India Industrial Pvt. Ltd.No.36/6 & 7, 1st FloorAshirwad BuildingD.B.Road, R.S. PuramCoimbatore-641002Ph: (0422) 4393520 / 4393529

WEST

Mumbai

GE India Industrial Pvt. Ltd.361/362, Solitaire Corporate ParkM. Vasanji Road, ChakalaAndheri (E), Mumbai-400093Ph: (022) 40101610Fax: (022) 40101611

EAST

Kolkata

GE India Industrial Pvt. Ltd.Horizon Building, 4th Floor 57, Chowringhee RoadKolkata-700071Ph: (033) 40034056Fax: (033) 40034071

Works:GE India Industrial Pvt. Ltd.Plot No. 42/1 & 45/14Electronic City - Phase IIBangalore-560100Ph: (080) 41113000Fax: (080) 28528469/552

HO:GE India Industrial Pvt. Ltd.The Millenia, Level-6, Tower B1 & 2, Murphy Road, UlsoorBangalore-560008Ph: (080) 41434000Fax: (080) 41434199Email: [email protected]

Toll Free No:18001024343

Customer Care:[email protected]

We are committed to continuous development and improvement of our products and the specifications aresubject to change without notice. For product availability and latest prices, please contact GE Sales Team.

For any further information, visit us at http://www.geindustrial.com

g and General Electric are registered trade marks of General Electric Co. USA©

Ahmedabad

GE India Industrial Pvt. Ltd.405-406, Kirtiman ComplexKinariwala House, Behind CitibankOff C.G. Road, Ahmedabad-380006Ph: (079) 65427385/55427389Fax: (079) 26460637

Pune

GE Money Financial Services LimitedShop No. 405-410, 4th FloorCity Point, Dhole Patil RoadPune-411001Mob: +91 9850867507

Cochin

GE India Industrial Pvt. Ltd.Mayur Business Center & MotelChittur Road, Pullepadi JunctionCochin-682035Ph: (0484) 2364139Fax: (0484) 4031400

Hyderabad

GE India Industrial Pvt. Ltd.5-2-45, Hyderbasti, RP RoadNear Gujarati High SchoolSecunderabad-500003Ph: (040) 27543162, 66311264Fax: (040) 66339272

1107

/MO

DG

LMC

B