ABOUT US
We have design and manufacturing facilities both in the USA and Europe producing a
comprehensive and cost-effective range of equipment designed for the power and process
industries. We are committed to producing quality products, systems and solutions for a
global market. Our expertise, gained from many years of experience in servicing these
international markets, allows us to introduce a high degree of systems flexibility and
customized solutions.
At Hathaway we are committed to close working relationships with our customers and aim
to be the supplier against whom others in the industry are compared.
With over 30 years exper ience, Hathaway is a market leader in
the development of instrumentat ion to cater for the speci f ic
needs of power ut i l i t ies throughout the wor ld.
Our areas of expert ise inc ludes Fault Recording, Power Qual i ty
Recording, Event Recording, Fault Locat ing. Circui t Breaker
Test ing, Circui t Breaker Condit ion Monitor ing, Remote Terminal
Units, Distr ibut ion Automat ion, Substat ion Integrat ion and
SCADA/DCS Systems.
Key customers inc lude the wor ldwide electr ic i ty generat ion,
transmiss ion and distr ibut ion companies, water ut i l i t ies and
the oi l and gas industry (SCADA/DCS and automat ion
systems).
@www.hathawaycorp.com
EQUIPMENT
2
TWS Travelling Wave Fault Locator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5
DSFL Distribution System Fault Locator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7
GPS Time Synchroniser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8
GLS Low Voltage Gradient Fault Locator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9
FPI, P2000 Low Voltage Locators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10
CBT Range - Circuit Breaker Test Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 11
Tap Changer, Micro-Ohm CBT Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13
RTR 200 Circuit Breaker Response Recorder . . . . . . . . . . . . . . . . . . . . . . . . . . page 14
IDM Data Acquisition System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3
BCM Range - Breaker Condition Monitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 15
RMS 900 Distribution Automation Controller . . . . . . . . . . . . . . . . . . . . . . . . . . page 17
SIS Substation Information Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 19
> FAULT RECORDING
> CONDITION MONITORING
> DISTRIBUTION AUTOMATION
> SUBSTATION INTEGRATION
> FAULT LOCATION
> BREAKER MAINTENANCE
IDM
A compact and economical multifunction data
acquisition system with unrivalled functionality
and performance
The IDM is designed to address the data recording
requirements of modern distr ibut ion or transmiss ion networks.
The product, when coupled with ReplayPlus software, provides
a powerfu l p lat form for the acquis i t ion, analys is and report ing
of data from power system substat ions.
Each IDM DAU - equipped with a 16-bit processor, 16-bit A/D and powerful DSP processor -
processes analog input data each cycle to compute, in real time, 100 power system
quantities including real and reactive power, sequence components, phasors, harmonics,
frequency, etc. These quantities are then used for simultaneous fault recording, disturbance /
slow scan recording, phasor measurement, power quality recording (EN50160) and can also
be made available to other substation IEDs for integration into SCADA systems.
> data acquis i t ion system
3
unr ival led product prof i le // IDM @
The future of data acquisition.
Today.
www.hathawaycorp.com
In addit ion to faul t and disturbance recording the system can
also inc lude power system monitor ing, phasor measurement,
event recording, power qual i ty recording, equipment condit ion
monitor ing and SCADA I/O.
An upgrade package for existing Hathaway DFRII's, based on the IDM hardware, is available
to provide the extra functionality of the IDM. This upgrade involves changing a number of
cards within the DAU, whilst still retaining the original signal conditioning and isolation
electronics, transforming it into a new fully integrated power system monitoring device.
IDM Profile
10 or 16 analog, 16 or 32 event acquisition unit
Fully multitasking operating system - VxWorks
Supports multiple concurrent applications
Network communications - Ethernet (TCP/IP), RS232 (PPP) and Internet / Intranet
Built in self-checking functions
�
�
�
�
�
4
equipment //
FAULT RECORDING
TWS
An advanced overhead line fault locator
combining high performance with unrivalled
accuracy
The Telefaul t TWS operates on the travel l ing wave pr inc ip le
and provides an accuracy of ±150m (±500ft) . I t can be used
on high voltage AC l ines of any length, inc luding those
contain ing sect ions of cable, paral le l c i rcu i ts, tapped loads and
ser ies capaci tors. I t can also be used on HVDC l ines.
The Telefault TWS provides three different of fault location; Type A, Type D and Type
E. In the Type A and D modes the fault location is determined using the transients generated
by the fault itself. In the Type E mode faults are located using the transients generated by the
re-closure of the circuit breaker onto the faulty line after the initial trip. The TWS is
unaffected by fault resistance and provides a consistent level of accuracy many times better
than conventional ‘impedance’ type fault locators. Phase to ground faults, phase to phase
faults and broken conductor faults, including those clear of ground where no fault current
flows, can all be located with the TWS.
modes
5
s imple faul t locat ion // TWS
> travel l ing wave fault locator
The cost effective fault locator.
A better solution.
The TWS package inc ludes TWS Base Stat ion software which
al lows ful l remote interrogat ion and waveform analys is of faul t
records inc luding direct measurement of faul t d istance, f i l ter
character ist ics, ampl i tude, expansion and compar ison of
previous faul t data with new data.
The standard version of Telefault TWS can accommodate up to eight line modules so that
eight circuits can be monitored simultaneously. An integral GPS time receiver is used to
provide the sub-microsecond timing accuracy required for Type D operation whilst multi-
channel high-speed transient recording is used for Type A and Type D operation.
TWS Profile
Travelling wave based fault location
Internal modem provided as standard for remote data retrieval and configuration
Simple and inexpensive installation
Optional interfacing to SCADA systems / substation IEDs
�
�
�
�
6
@www.hathawaycorp.com
equipment //
FAULT LOCATION
DSFL
An inexpensive overhead line fault locator for
small transmission networks or distribution
systems
The Telefaul t DSFL is des igned to accurate ly locate faul ts on
unbranched high voltage overhead l ine networks which may
inc lude short lengths of underground cable. When used on
more complex branched networks the DSFL wi l l accurate ly
locate faul ts on the main l ine and ident i fy a faulty branch.
The Telefault DSFL uses the properties of travelling waves initiated by a fault to determine
the position of the fault. The preferred method of detection of the travelling waves is through
the use of simple ‘clamp on’ sensors which are placed around the secondary wiring of
existing protection CTs. Where no CTs are available, the signals may be derived from existing
capacitor voltage transformers or power line signalling couplers.
7
> distr ibut ion system fault locator
inexpensive, easy, prec ise // DSFL
GPS
A simple, inexpensive and highly accurate
substation clock time synchroniser that can be
used with all makes of equipment
The Telefaul t GPS provides t iming accurate to ±1µs using the
internat ional sate l l i te Global Pos i t ioning System (GPS).
Compact and easy to insta l l , i t provides output s ignal formats
to match the requirements of a l l avai lable Disturbance
Recorders, Sequence of Event Recorders and SCADA systems.
The Telefault GPS offers electrical power systems operators an inexpensive means of
significantly improving both the value of their investment in equipment and the usefulness of
the acquired data. Using time signals transmitted by the NAVSTAR constellation of GPS
satellites, the GPS meets all the needs of all differing equipment types and manufacturers.
Local time offset from UTC can be set by the operator or at the factory.
8
> t ime synchroniser
maximis ing data value // GPS
equipment //
FAULT LOCATION
One set of GLS equipment comprises three identical voltage monitoring units configured as
one Master and two Slaves (A and B). These identities are held in software and displayed
when the units are switched on. They communicate by infra-red and the distance to fault is
calculated and displayed by the Master unit. The GLS system has been built into small waterproof
cases which can be left connected in most link boxes and lighting columns.
GLS
An advanced and simple to use system for
locating intermittent and permanent faults on
low voltage cables
The Telefaul t GLS provides a means of pre- locat ing faults on
low voltage cables by the voltage gradient method. These
state of the art instruments make poss ib le the instantaneous
measurement and recording of vol tages along a faulty cable
whi le faul t current is f lowing.
9
> low voltage gradient faul t locator
state of the art // GLS
FPIP2000
FPI - a safe and simple system for sectionalising
intermittent faults on low voltage power cables
An inexpensive device for faul t sect ional isat ion to reduce both
customer interrupt ions and customer minutes lost.
Combines the funct ions of a high accuracy TDR and a
disturbance recorder in a compact and robust portable unit .
P2000 - a revolutionary instrument for locating
all types of faults on low voltage power cables
The Telefault FPI Fault Passage Indicators (bottom right) are simply placed over the links in
link boxes along the route of a suspect cable. Following any subsequent fuse operation any
FPI units between the substation and the fault point will be triggered thereby allowing the
faulty section to be identified. A clamp on version of the FPI is also available.
The Telefault P2000 (bottom left) is suitable for all types of low voltage cable faults and
especially the difficult and troublesome intermittent fault. It is connected simultaneously to
all 3 phases of the faulty LV cable for triggering/voltage recording and to allow TDR testing
on any combination of phases. Remote operation is available via the internal GSM modem.
10
> low voltage locators
faul t locat ion solut ions // FPI, P2000
equipment //
FAULT LOCATION
A powerful, cost effective test system providing
highly accurate information for factory and field
testing of circuit breakers
The easy to use breaker tester.
With results anyone can understand.
The CBT-200 and CBT-400 are sel f-conta ined portable test sets
designed to perform timing and test ing on high voltage circui t
breakers. Microprocessor based, the systems have the abi l i ty
to store test records in internal memory which can be
downloaded to a PC at the operators convenience.
The CBT-200 / 400 systems can monitor contact opening / closing, trip / close coil currents
and mechanism travel and velocity. The CBT can perform automatic result analysis using pre-
programmed limits for expected results. When a breaker test is carried out the CBT
compares the actual results with those expected. Any variances outside the limits are
indicated on the print-out and LCD display. Results are presented in both tabular and
graphical format using the built-in fixed head thermal printer.
Test resul ts can also be downloaded from the CBT to
ReplayPlus where they can be analyzed and archived. A Remote
Conf igurat ion program al lows modi f icat ion of test parameters
via a PC and results may also be transferred to Microsoft
Access for easy generat ion and customis ing of reports.
16 different set-up configurations can also be stored within the CBT, any of which can be
accessed on site. All results can be stored within the CBT's internal memory and retrieved at
a later date via direct computer link or modem, eliminating the requirement for a PC to be
carried on site.
CBT Profile
Simple to operate, can be used by less experienced personnel
Test sequencing and cycling
Dynamic Resistance and Tap Changer interfaces available
�
�
�
�
Up to two breaks per phase (CBT-200) or up to four breaks per phase (CBT-400)
11 12
@www.hathawaycorp.com
CBT> circui t breaker test system
inte l l igent resul ts analys is // CBT
equipment //
BREAKER MAINTENANCE
13
> cbt accessor ies
enhancing CBT capabi l i t ies // Tap Changer, Micro-Ohm
Tap ChangerMicro-Ohm
Tap Changer - a clear insight into the mechanical
condition of a tap changer transformer
This diagnost ic tool makes use of the var iable sample rates of
the CBT to perform two dist inct tests.
This interface measures both Main and Arc ing contact t imes,
length and res istance dur ing a ‘dynamic ’ c lose-open operat ion.
Micro-Ohm - a safe, simple facility to record the
‘dynamic’ contact resistance of a circuit breaker
The interface (bottom left), performs a long duration test to quickly identify a high resistance
contact as the transformer is switched from first to last tap and a short duration record
between two taps to identify the integrity and switching sequence of the diverter resistors.
With the Micro-Ohm Interface (bottom right), all measurements are carried out during routine
testing. This is immensely beneficial for use on circuit breakers where it may be impractical
to dismantle and visually inspect the condition of the contacts, for example SF switchgear.6
RTR
A diagnostic tool which can accurately assess the
condition of circuit breakers with minimum of
time, effort and expense
The RTR 200 al lows a breaker to be tested whi le remaining in
serv ice. The system has been designed to monitor several
common signals in the contro l c i rcu i try of the c ircui t breaker,
typica l ly tr ip and close coi l current, supply voltage dip, A, B or
C3 auxi l iary contacts and tr ip and close in i t iat ion.
These and other electrical signals are brought to a permanently installed connector in the
breaker mechanism cabinet. To perform a test the RTR 200 recorder is connected to this pre-
wired plug and the breaker is operated remotely. The RTR 200 stores the data from the test
and is then disconnected to be moved to the next breaker. The resulting trace can be
considered as the fingerprint of a given circuit breaker. The essence of the RTR-200 concept
is the comparison of these fingerprints.
14
> circui t breaker response recorder
reducing breaker downt ime // RTR
equipment //
BREAKER MAINTENANCE
BCM
An early warning system for detecting breaker
problems whilst providing a historical reference
for extending breaker maintenance intervals
The BCM range of breaker condit ion monitors analyse every
c ircui t breaker operat ion by compar ing the new recorded data
against a stored reference with programmed l imits. Contact
duty (e.g. i²t) is accumulated for each phase and alarms are
act ivated when maintenance or c loser inspect ion is required.
The BCM 200
The BCM 200E
is used on a one per breaker basis and monitors trip and close coil current
profiles, auxiliary contact timing, battery voltage and charging ripple and main contact duty
(e.g. i²t).
is also used on a one per breaker basis but has additional inputs to monitor
the extra signals on transmission breakers with three independent mechanisms for each
phase. The BCM 200E monitors trip, backup trip and close coil current profiles, auxiliary
contact timings, battery voltage and charging ripple, main contact duty (e.g. i²t), mechanism
travel and velocity and SF gas density.6
15
> breaker condit ion monitor
increas ing breaker re l iabi l i ty // BCM
Extending breaker maintenance intervals.
Safely.
When used with ReplayPlus software, addit ional informat ion
can be obtained on protect ion performance, capture of faul t
data, ident i fy maintenance requirements and generate
customized reports. The BCM range is a complete solut ion
complement ing any condit ion based maintenance program.
The SSM is used to monitor up to twelve distribution breakers in a single panel or in close
proximity of one another. For each breaker the SSM monitors trip and close coil current
profiles, auxiliary contact timing, battery voltage and charging ripple, AC voltage dip and
duration and main contact duty (e.g. i²t).
BCM Profile
Automatic ‘fingerprint’ comparison of breaker characteristics
Design that easily fits into breaker control cabinet
Local and remote communications
�
�
�
�
Available in a one per breaker or one per distribution substation configuration
16
@www.hathawaycorp.com
equipment //
CONDITION MONITORING
A flexible, reliable and inexpensive system to
monitor and control feeder switchgear on
distribution automation systems
The RMS-900 is a mult i funct ion device which combines the
funct ional i ty of a smal l SCADA RTU, faul t detector, PLC and
power transducers into a s ingle cost ef fect ive, compact unit
sui table for substat ion, pad-mount and pole-mount
appl icat ions.
The RMS-900 combines the latest electronic, software and manufacturing technologies to
achieve remote control and / or automatic local control, of circuit breakers, tap changers,
reclosers, sectionalizers or capacitor switches. It combines the functions of a traditional
SCADA RTU with the added benefits of small size and low cost, transducerless
measurement of AC power quantities, fault detection and harmonic analysis.
17
RMS> distr ibut ion automat ion contro l ler
SCADA RTU, power IED, PLC // RMS
The advanced controller of choice.
For all power distribution applications.
18
@www.hathawaycorp.com
Example applications include a Distributed RTU (multiple RMS-900s networked and reporting
to another RTU, SIS or SCADA system), a Switch Controller, a Tap Changer Controller or a
Capacitor Bank Switch Controller. The RMS can monitor both sides of a switch and report
status, receive and implement remote control commands, perform automatic PLC-style
control and perform auto-sectionalising and auto-reclosing as part of an automation scheme.
RMS Profile
9 AC analog inputs for direct connection to CTs, PTs and LPSs
Digital signal processing - current, volts, power, frequency and phase angle measurement
Advanced options include alarm limits, fault detection and harmonic content
Optional Echelon FT-10 L T network portON ALK
�
�
�
�
A range of Windows PC tools are avai lable for the RMS-900
compris ing Fault Detect ion and Display software, a Remote
Conf igurat ion Toolk i t (RCT) and a powerfu l ISaGRAF IEC
61131-3 compl iant programming workbench.
equipment //
DISTRIBUTION AUTOMATION
SIS
The most reliable communications gateway to
your substations providing secure, high-speed
data retrieval and control
The SIS is designed to gather data from IEDs and I/O modules,
process this data and make relevant usefu l informat ion
avai lable to one or mult ip le users, at one or more locat ions,
s imultaneously. Communicat ion can be via ser ia l l inks,
LANs/WANs, corporate Intranets and the Internet.
Each SIS can be equipped with multiple serial ports (from 3 to 32 depending on the model)
with each port able to support an independent protocol. This allows communication to be
established between the SIS and almost any IED in the substation, for data retrieval and
control purposes. Information gathered by an SIS can be communicated over a TCP/IP LAN
or WAN to other SIS units or via serial link to an existing SCADA / EMS system in its native
protocol.
> substat ion informat ion server
19
powerfu l , f lex ib le, secure // SIS @
Providing controllable information.
To everyone that needs it.
www.hathawaycorp.com
The information gathered can also be presented as Web pages, allowing users to view live
substation data using standard web-browsers. Communication between SIS units is secure,
making it safe to gather information and send control commands over the Internet, or
company WAN.
SIS Profile
Ethernet connectivity
Up to 32 independent serial ports
Multiple protocols per SIS
Up to 5000 real time points
Custom designed for your
application
RTU functionality with direct
connected I/O
Supports TCP/IP, FTP, JAVA, SQL,
Oracle warehouse interface
�
�
�
�
�
�
�
20
Web browser
LAN/WAN
Substation Substation
IED IEDIED IEDIED IED
SIS SIS
SCADA / EMS
equipment //
SUBSTATION INTEGRATION
ReplayPlus
A proven, state of the art multitasking software
package providing a powerful platform for power
network management
ReplayPlus is a f lex ib le, h igh performance 32-bit Windows
conf igurat ion and communicat ions package al lowing power
ut i l i t ies to retr ieve, analyse and manage informat ion from a
wide range of Hathaway products throughout their
transmiss ion and distr ibut ion networks.
The Master Station suite of software applications runs on Windows 95/98, 2000
and Windows NT. It provides full configuration, data retrieval, display, analysis and printing
capabilities. Predefined display screen configurations can be used to allow data to be
displayed quickly in an easily interpreted format. As each record is transferred to the
Master Station, analysis software extracts a series of key parameters that are
stored in a database, ready for later analysis. There are also provisions to integrate third party
applications into to extend its analysis capabilities. Windows .dll library files are
available to provide developers with easy access to the raw data within the record files.
Replay
Replay
Replay
™
™
™
Plus
Plus
Plus
> master stat ion
21
analyse, conf igure, archive // ReplayPlus
Powerful, yet user friendly.
The leading fault record analysis software.
To provide the user with ‘Open’ access to data, ReplayPlus is
bui l t around a Microsoft Access database. The use of Access
also means that the extensive range of f lex ib le database tools
can be used to analyse, f i l ter and present the data acquired
from substat ion devices in a user conf igurable manner.
Replay™Plus Functions
Communications
Device configuration
Record viewer and printing
Real time phasors display
Harmonic analysis
Fault location
Automatic data analysis
COMTRADE file import / export
�
�
�
�
�
�
�
�
@www.hathawaycorp.com
22
accessor ies //
SOFTWARE
power appl icat ions
short form catalogue
15 Wildflower Way
Belfast
BT12 6TA
Northern Ireland
Tel: +44 28 9022 5200
Fax: +44 28 9022 5225
8228 Park Meadows Drive
Littleton
Colorado 80124
USA
Tel: +1 303 799 8200
Fax: +1 303 799 8880
7661 South 180th Street
Kent
Washington 98032-1048
USA
Tel: +1 425 251 0211
Fax: +1 425 251 0113
102 Lakefront Drive
Hunt Valley
Maryland 21030
USA
Tel: +1 410 771 0022
Fax: +1 410 771 9579
innovat ion // qual i ty+expert [email protected]
locat ions //