PRODUCTCATALOGUE

2016

SPLIT / WINDOW

AIR CONDITIONERS LINEUP

Page 2: PRODUCT CATALOGUE 2016 - zagzoog.com · • Note : Specifications are based on the following conditions. Cooling (SASO2681.T1) : Indoor temperature of 27°CDB / 19°CWB, and outdoor

2

NEW

NEW

NEW

NEW

NEW

NEW

INDOOR UNIT LINEUP

18,000

24,000

25,000

30,000

36,000

40,000

50,000

60,000

Capacity(BTU/h)

ASSA18FMTAASSA18UMTA

ASSA24FMTAASSA24UMTA

ASSA30FMTAASSA30UMTA

ASSA36FETAASSA36UETA

Duct Type

ARSA18FMTAARSA18UMTA

ARSA25FMTAARSA25UMTA

AUSA40FRTAAUSA40URTA

AUSA50FRTAAUSA50URTA

AUSA18FRTAAUSA18URTA

AUSA25FRTAAUSA25URTA

AXSS24FHTB

AXSS18FHTA

Wall Mounted TypeWindow Type

ARSA40FMTBARSA40UMTB

ARSA50FMTBARSA50UMTB

ARSA60FHTBARSA60UHTB

Cassette Type

Page 3: PRODUCT CATALOGUE 2016 - zagzoog.com · • Note : Specifications are based on the following conditions. Cooling (SASO2681.T1) : Indoor temperature of 27°CDB / 19°CWB, and outdoor

3

PRODUCT SUMMARY

New Energy Labelling Requirement SASO2663/2014

The number of stars displayed on the energy label. Available stars are between a

minimum of one and a maximum of ten. It is considered as an indication of the claimed

energy efficiency of a model at rated conditions. A higher star rating indicates a higher

energy efficiency. It is derived from the actual measured EER. Our models has reached

the highest energy efficiency level that is now shown on energy labels in Saudi Arabia.

ENERGY EFFICIENCY CLASSIFICATION

HYPER TROPICAL SPEC

R22 depletes the ozone layer, however, R410A is energy-efficient refrigerant with ODP “0”.

NEW REFRIGERANT

SASO2663/2014

R410A R22

EER

18.116.815.614.513.412.411.510 9.7 9 8.5

>>>>>>>>>>>>

EEREEREEREEREEREEREEREEREEREEREEREEREER

>

18.116.815.614.513.412.411.510 9.7 9 8.5 7.5 7.5

109.59

8.58

7.57654321

Energy rating classification Example of Label -Cooling only

Star RatingEER limits (rested value)

(Btu/h)/ w at T1

Temperature rise prevention device (thermal protector) installed

Gas leak protection and low voltage protection OLP (Over Load Protection) device installed

High-output torque motor Torque improved by increasing the thickness of the laminated core and

improving the coil winding

High durability vaneSurface hardness increased

High durability rolling piston Hardness improved by changing the material

High durability crankshaft used Hardness improved by adding a coating

1.Improvement of compressor drive materials for greater durability (Hardness increased).

2.Use of high efficiency, high torque motor

3.Complete protection functions against abnormal temperature rise and abnormal pressure rise

Main features

SUPER PROTECTION(for Split Type)

Enhancement of protection function

Strong blue finAdoption of strong blue fin provides strong protection against rust and salt damage.

Super powerMore capacity than old models under overload condition (52°C).(Window Type: 60°C)

Super low voltage operationOur Hyper Tropical Compressor can be operated even at low voltage.

Super Hi-EERHighly energy efficiency

Super quietSelect the lower noise level.

Designed by Fujitsu General the Japanese company whohas long term experience in air conditioning products

HYPER TROPICAL COMPRESSOR

Page 4: PRODUCT CATALOGUE 2016 - zagzoog.com · • Note : Specifications are based on the following conditions. Cooling (SASO2681.T1) : Indoor temperature of 27°CDB / 19°CWB, and outdoor

• Note : Specifications are based on the following conditions. Cooling (SASO2681.T1) : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. Cooling (SASO2681.T3) : Indoor temperature of 29°CDB / 19°CWB, and outdoor temperature of 46°CDB / 24°CWB. Heating (SASO2681.H1) : Indoor temperature of 20°CDB, and outdoor temperature of 7°CDB / 6°CWB• The protective function might work when using it in environment out of the temperature range mentioned above.• The maximum current is the maximum value when operated within the operation range.*:That specification is not fixed yet.

SPECIFICATIONS

V/Ø/Hz

WBtu/h

WA

Btu/hWI/h(pints/h)

WBtu/h

WA

Btu/hW

WWA

W/WA

m3/hmm

kg(lbs)mm

kg(lbs)

Model Name

Indoor unit(High)

Indoor unit

Outdoor unit

Indoor unitOutdoor unit

230/1/607

10,26035,0003,04013.4

11.51

*

8,94030,5003,68016.38.29

11,0003,54015.83.11

*1,410

340×1,150×28017(37)

1290×900×330106(233)

ASSA36UETAAOSA36UETAS

230/1/607

10,26035,0003,04013.4

11.51

*

8,94030,5003,68016.38.29

*1,410

340×1,150×28017(37)

1290×900×330109(240)

ASSA36FETAAOSA36FETAS

230/1/607.5

8,06027,5002,39010.5

11.512.6(4.6)

7,03024,0002,89012.78.30

8,1502,34010.2

16.51,350

340×1,150×28018(39)

914×970×37079(174)

ASSA30UMTAAOSA30UMTAS

230/1/607

8,06027,5002,39010.5

11.512.6(4.6)

7,03024,0002,89012.78.30

16.51,350

340×1,150×28018(39)

914×970×37077(169)

ASSA30FMTAAOSA30FMTAS

230/1/607

6,60022,6001,960

8.711.53

2.5(4.4)

5,70019,5002,35010.48.30

6,9501,950

8.63.5618.5

1,150320×998×238

15(33)830×900×330

64(141)

ASSA24UMTAAOSA24UMTAH

230/1/607

6,60022,6001,960

8.711.53

2.5(4.4)

5,70019,5002,35010.48.30

18.51,150

320×998×23815(33)

830×900×33064(141)

ASSA24FMTAAOSA24FMTAH

230/1/607.5

5,35018,3001,590

7.411.51

2.0(3.5)

4,57015,6001,880

8.48.30

5,4501,560

7.23.4915.0985

320×998×23815(33)

830×900×33063(139)

ASSA18UMTAAOSA18UMTAH

230/1/607

5,45018,6001,610

7.411.55

1.9(3.3)

4,66015,9001,920

8.68.28

16.0985

320×998×23815(33)

650×830×32050(110)

ASSA18FMTAAOSA18FMTAH

Power SourceEnergy LabelCooling (T1 condition)

Capacity

Input PowerCurrentEERMoisture Removal

Cooling (T3 condition)

Capacity

Input PowerCurrentEER

Heating (H1 condition)CapacityInput PowerCurrentCOP

Max. Running Current (Cooling)Airflow Rate

DimensionsH×W×D

Weight

4

Cooling

ASSA36FETACooling/Heating

ASSA36UETA

Cooling

ASSA30FMTACooling/Heating

ASSA30UMTA

Cooling

ASSA24FMTACooling/Heating

ASSA24UMTA

Cooling/Heating

ASSA18UMTACooling

ASSA18FMTA ASSA24UMTA ASSA24FMTAASSA18UMTA

ForASSA18UMTA ASSA24FMTA ASSA24UMTA

ForASSA18FMTA

ASSA18FMTA

Handy Type

Handy Type MODE SWING

SET

SET

TIMER

SLEEP

START/STOP

TEST RUNTTT RESETCLOCK ADJUST

FANFAN

TEMP

TEMP

NEWNEW

NEWNEW

ASSA30UMTAASSA30FMTA

ForASSA30FMTAASSA30UMTA

ASSA36UETAASSA36FETA

ForASSA36FETAASSA36UETA

TENTATIVE

Page 5: PRODUCT CATALOGUE 2016 - zagzoog.com · • Note : Specifications are based on the following conditions. Cooling (SASO2681.T1) : Indoor temperature of 27°CDB / 19°CWB, and outdoor

5

Powerful Cooling

Super High

High

Med

Low

Quiet

5 speed

+

*One touch powerful cooling mode: Continuous operation for 30 minutes at maximum air volume

10.19 Btu/hW

11.51 Btu/hW13% up

42% up

22,900 Btu/h

24,000 Btu/h5% up

Powerful

High

Med

Low

Quiet

4 speed

+

Powerful mode(30 / 36 class)

15m 25m

than current powerful mode

20% up

Airflow

NEW model Current model

25m!

Temperature °C22.0 23.0 24.0 25.0 26.0 27.0

10m

10m

60cm

2.5m

Indoor temperature of 27°C DB, and outdoor temperature of 35°CDBSetting temperature:24°CDB, High airflow mode, 30 class CFD simulation results after 250 seconds from the start.

than current model

18% faster!

Reach the setting temp.

NEW model Current model

Powerful mode(30 / 36 class)

15m 25m

25m!

Reach thesetting temp.

NEW model Current model

(Btu/h, 230V, 60Hz, T3 condition)

NEW model

(Btu/h, 220V, 60Hz, T3 condition)

Current model

(Btu/hW, 230V, 60Hz, T1 condition)

NEW model

(Btu/hW, 220V, 60Hz, T1 condition)

Current model

30 cooling model

30 cooling model

30 Heat & Cool model

8.10 Btu/hW

11.51 Btu/hW

WALL MOUNTED TYPE

Long-reach airflow up to 25m is provided by optimized airflow design.

Powerful airflow

5-Speed fan control with added Powerful Cooling mode is provided.

* 30 / 36 class

More powerful fan speed control

Higher cooling capacity is achieved at the ambient temperature of 52°C condition.

Powerful cooling

New models accelerate to cool air quicker to reach the setting temperature in the entire

room than the current models do.

Faster cooling

Higher EER is achieved by the new technolo-gies and new refrigerant.

High energy saving

Page 6: PRODUCT CATALOGUE 2016 - zagzoog.com · • Note : Specifications are based on the following conditions. Cooling (SASO2681.T1) : Indoor temperature of 27°CDB / 19°CWB, and outdoor

• Note : Specifications are based on the following conditions. Cooling (SASO2681.T1) : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. Cooling (SASO2681.T3) : Indoor temperature of 29°CDB / 19°CWB, and outdoor temperature of 46°CDB / 24°CWB. Heating (SASO2681.H1) : Indoor temperature of 20°CDB, and outdoor temperature of 7°CDB / 6°CWB• The protective function might work when using it in environment out of the temperature range mentioned above.• The maximum current is the maximum value when operated within the operation range.

SPECIFICATIONS

V/Ø/Hz

WBtu/h

WA

Btu/hWI/h(pints/h)

WBtu/h

WA

Btu/hW

WWA

W/WA

m3/hmm

kg(lbs)mm

kg(lbs)

Model Name

Indoor unit(High)

Indoor unit

Outdoor unit

Indoor unitOutdoor unit

400/3/607

15,20052,0004,520

7.911.50

3.4(6.0)

13,00044,4005,360

9.28.28

14,6003,850

7.33.7914.5

3,350360×1,400×850

67(147)1,290×900×330

106(233)

ARSA60UHTBAOSA60URTBS

400/3/607

15,20052,0004,520

7.911.50

3.4(6.0)

13,00044,4005,360

9.28.28

14.53,350

360×1,400×85067(147)

1,290×900×330105(231)

ARSA60FHTBAOSA60FRTBS

400/3/607

12,40042,4003,680

6.311.52

3.2(5.6)

11,20038,1004,600

7.58.28

12,7003,350

5.83.7911.5

2,500300×1,400×700

44(97)1,290×900×330

102(224)

ARSA50UMTBAOSA50URTBS

400/3/607

12,40042,4003,680

6.311.52

3.2(5.6)

11,20038,1004,600

7.58.28

11.52,500

300×1,400×70044(97)

1,290×900×330100(220)

ARSA50FMTBAOSA50FRTBS

230/1/607

11,00037,5003,26015.0

11.503.1(5.5)

9,67033,0003,98018.58.29

11,3003,15014.53.5923.0

2,000300×1,400×700

44(97)1,290×900×330

105(232)

ARSA40UMTBAOSA40UBTBS

230/1/607

11,00037,5003,26015.0

11.503.1(5.5)

9,67033,0003,98018.58.29

23.02,000

300×1,400×70044(97)

1,290×900×330103(227)

ARSA40FMTBAOSA40FRTBS

230/1/607

6,70022,9001,990

8.811.51

2.3(4.0)

5,80019,8002,39010.58.28

6,9001,900

8.63.6318.5

1,200270×1,135×700

38(84)830×900×330

65(143)

ARSA25UMTAAOSA25UBTAH

230/1/607

6,70022,9001,990

8.811.51

2.3(4.0)

5,80019,8002,39010.58.28

18.51,200

270×1,135×70038(84)

830×900×33065(143)

ARSA25FMTAAOSA25FBTAH

230/1/607

5,35018,3001,590

7.411.51

1.5(2.6)

4,63015,8001,900

8.68.32

5,3001,550

7.03.4215.0

1,050270×1,135×700

38(84)830×900×330

64(141)

ARSA18UMTA AOSA18UBTAH

230/1/607

5,45018,7001,620

7.411.54

1.6(2.8)

4,75016,2001,950

8.78.31

16.01,050

270×1,135×70038(84)

650×830×32050(110)

ARSA18FMTAAOSA18FBTAH

Power SourceEnergy LabelCooling (T1 condition)

Capacity

Input PowerCurrentEERMoisture Removal

Cooling (T3 condition)

Capacity

Input PowerCurrentEER

Heating (H1 condition)CapacityInput PowerCurrentCOP

Max. Running Current (Cooling)Airflow Rate

DimensionsH×W×D

Weight

6

Wired Type(With Weekly Timer)

Wired Type(With Weekly Timer)

Wired Type(With Weekly Timer)

Cooling

ARSA25FMTACooling/Heating

ARSA25UMTA

Cooling/Heating

ARSA18UMTACooling

ARSA18FMTA ARSA25UMTA ARSA25FMTAARSA18UMTA

ForARSA18UMTA ARSA25FMTA ARSA25UMTA

ForARSA18FMTA

ARSA18FMTA

Cooling

ARSA50FMTBCooling/Heating

ARSA50UMTB

Cooling/Heating

ARSA40UMTBCooling

ARSA40FMTB

Cooling

ARSA60FHTBCooling/Heating

ARSA60UHTB

Page 7: PRODUCT CATALOGUE 2016 - zagzoog.com · • Note : Specifications are based on the following conditions. Cooling (SASO2681.T1) : Indoor temperature of 27°CDB / 19°CWB, and outdoor

4-Step of the static pressures can be selected by the remote controller.(40 / 50 : 30, 60, 90, 120 Pa) (60 : 60, 100, 130, 160 Pa)

Assemble again in ceiling

Separate on floor

Assemble again in ceiling

7

DUCT TYPE

Air Stabilizer is provided to minimize loss of airflow which enables to reduce the power input of the fan motor.

* At Cooling High mode

with 2,000(m3/h)(40 class)

37dB*(A)

(40 / 50 class)

Max.120Pa(60 class)

Max.160Pa

with 2,500(m3/h)(50 class)

40dB*(A)with 3,350(m3/h)

(60 class)

41dB*(A)

(40 / 50 class)

22% up

Heat-ExchangerVolume

(60 class)

13% up

Heat-ExchangerVolume

V-shape heat exchangerAir StabilizerTop view

The lowest operating sound level with large air volume in cooling operation is provided among the competitors.

Low Operation Sound With Large Air Volume

The key technologies of V-Shape Heat-Exchanger and Air Stabilizer are provided as special features of this product.

Key Technologies For High Efficiency

The indoor unit is able to cover various duct designs thanks to the employment of DC fan motor.

Adjustable Static Pressure

As the indoor unit is too big to lift up to ceiling in the original structure, it can be separated on floor and

assembled it again in the ceiling.

Separated Indoor unit ( 60 model only)

Page 8: PRODUCT CATALOGUE 2016 - zagzoog.com · • Note : Specifications are based on the following conditions. Cooling (SASO2681.T1) : Indoor temperature of 27°CDB / 19°CWB, and outdoor

• Note : Specifications are based on the following conditions. Cooling (SASO2681.T1) : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. Cooling (SASO2681.T3) : Indoor temperature of 29°CDB / 19°CWB, and outdoor temperature of 46°CDB / 24°CWB. Heating (SASO2681.H1) : Indoor temperature of 20°CDB, and outdoor temperature of 7°CDB / 6°CWB• The protective function might work when using it in environment out of the temperature range mentioned above.• The maximum current is the maximum value when operated within the operation range.*:That specification is not fixed yet.

SPECIFICATIONS

V/Ø/Hz

WBtu/h

WA

Btu/hWI/h(pints/h)

WBtu/h

WA

Btu/hW

WWA

W/WA

m3/hmm

kg(lbs)mm

kg(lbs)

Model Name

Indoor unit(High)

Indoor unit

Outdoor unit

Indoor unitOutdoor unit

60/3/4007

12,00041,0003,560

6.111.52

*

10,65036,400

4.397.2

8.29

12,7003,350

5.83.79

*2,000

288×840×84029

1290×900×330102

AUSA50URTAAOSA50URTCS

60/3/4007

12,00041,0003,560

6.111.52

*

10,65036,400

4.397.2

8.294.39

*2,000

288×840×84029

1290×900×330100

AUSA50FRTAAOSA50FRTCS

60/1/2307

11,00037,5003,26015.0

11.50

*

9,67033,0003,98018.58.29

11,3003,15014.53.59

*1,900

288×840×84029

1290×900×330105

AUSA40URTAAOSA40UBTCS

60/1/2307

11,00037,5003,26015.0

11.50

*

9,67033,0003,98018.58.29

*1,900

288×840×84029

1290×900×330103

AUSA40FRTAAOSA40FBTCS

60/1/2307

6,70022,9001,990

8.811.51

*

5,80019,8002,39010.58.28

6,9001,900

8.63.63

*1,150

246×840×84024

830×900×33065

AUSA25URTAAOSA25UBTBH

60/1/2307

6,70022,9001,990

8.811.51

*

5,80019,8002,39010.58.28

*1,150

246×840×84024

830×900×33061

AUSA25FRTAAOSA25FBTBH

60/1/2307

5,35018,3001,590

7.411.51

*

4,63015,8001,900

8.68.32

5,3001,550

7.03.42

*1,050

246×840×84024

650×830×32052

AUSA18URTAAOSA18UBTBH

60/1/2307

5,45018,7001,620

7.411.54

*

4,75016,2001,950

8.78.31

*1,050

246×840×84024

650×830×32050

AUSA18FRTAAOSA18FBTBH

Power SourceEnergy LabelCooling (T1 condition)

Capacity

Input PowerCurrentEERMoisture Removal

Cooling (T3 condition)

Capacity

Input PowerCurrentEER

Heating (H1 condition)CapacityInput PowerCurrentCOP

Max. Running Current (Cooling)Airflow Rate

DimensionsH×W×D

Weight

8

Cooling

AUSA25FRTACooling/Heating

AUSA25URTA

Cooling

AUSA18FRTACooling/Heating

AUSA18URTA

NEWNEW

NEWNEW

Cooling

AUSA50FRTACooling/Heating

AUSA50URTA

Cooling

AUSA40FRTACooling/Heating

AUSA40URTA

NEWNEW

NEWNEW

AUSA25URTA AUSA25FRTAAUSA18URTA

ForAUSA18URTA AUSA25FRTA AUSA25URTA

ForAUSA18FRTA

AUSA18FRTA

Wired Type

Wired Type

TENTATIVE

Page 9: PRODUCT CATALOGUE 2016 - zagzoog.com · • Note : Specifications are based on the following conditions. Cooling (SASO2681.T1) : Indoor temperature of 27°CDB / 19°CWB, and outdoor

9

CASSETTE TYPE

*Option Wired RC (Touch Panel) only

* Comfortable air conditioning by preventing direct blowing of cold air and by providing swinging air flow simultaneously

*Efficient air conditioning in accordance with the room layout

New cassette series have been achieved quiet operation and large air volume by unique circular flow design and offer quiet

comfortable activities.

Quiet operation and Large air volume

Each louver can be set individually by Touch Panel Wired Remote Controller to enjoy the comfort of different directional

airflows according to various room layouts.

Individual louver control(Option)

New cassette series have been achieved 7-Star in SASO.High energy efficiency operation can be done.

ALL 7-Star models

ASUA**URTA

50402518

11.51 11.50

18

11.51 11.52

AUSA**FRTA

50402518

11.51 11.50

18

11.54 11.52

T1(Btu/hW)

AUSA**F(U)RTAAUSA**F(U)RTA

5040251818 25 400 50

43

33

44

35

48

44

4946

50402518188 25 400 500

640

1050 1100 1150

1500

19001650

2000

Hi(dB) Hi(m3/h)

NEW model Current model

Comfortable!

Ø7mm high density heat exchanger

New DC fan motor

High efficient turbo fan

Seamless airflow louver

Achieve a comfortable air conditioning spread to every corner of the room by

circular flow & wide vertical airflow.

Uniform temperature air conditioning

New Cassette type realizes Circular Flow to blow large airflow in 360º direction by mounting high performance DC fan motor,

new turbo fan and unique seamless airflow louver design.

Unique Circular Flow design

Page 10: PRODUCT CATALOGUE 2016 - zagzoog.com · • Note : Specifications are based on the following conditions. Cooling (SASO2681.T1) : Indoor temperature of 27°CDB / 19°CWB, and outdoor

10

Feature

Moisture Removal

Double Swing Automatic

Automatic Louvers

Auto Shut Louvers

Automatic fan speed

Auto Restart

Sleep Timer

Program Timer

Weekly Timer

Connectable Distributing Duct

Connectable Fresh Air Duct

Powerful Mode

Economy Mode

ARSA25FMTA ARSA25UMTAARSA18FMTA ARSA18UMTA ASSA18FMTA ASSA18UMTA

ASSA24FMTA ASSA24UMTAASSA30FMTA ASSA30UMTAASSA36FETA ASSA36UETA

ARSA40FMTB ARSA40UMTBARSA50FMTB ARSA50UMTBARSA60FHTB ARSA60UHTB

AUSA18FRTA AUSA18URTAAUSA25FRTA AUSA25URTAAUSA40FRTA AUSA40URTAAUSA50FRTA AUSA50URTA

Model

Program TimerThis digital timer allows selection of one of four options: ON, OFF, ON OFF or OFF ON

Auto RestartIn the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before once the power supply is restored.

Economy ModeThermostat setting automatically changesaccording to the temperature to avoidunnecessary cooling and heating.

Moisture RemovalThe computer effectively dehumidifies the air.

Double Swing AutomaticComplex swing action of louvers enables automatically to swing both horizontal and vertical directions.

Auto-Shut LouversThe auto shut louvers close or open automatically when the unit stops or starts.

Weekly TimerDifferent on-off times can be set for each day.

Powerful ModeOperates at maximum air flow in the cool and fan operation modes, and quickly makes the room comfortable.

Sleep Timer The micro-computer gradually changes the room temperature automatically to help you enjoy a comfortable night's sleep.

Automatic LouversThe position of the louvers is set automatically to match the operating mode. The louvers can also be adjusted using the remote controller.

Automatic fan speedThe micro-computer automatically adjusts the airflow effectively and properly according to the changes of room temperature.

FEATURE SUMMARY FOR SPLIT TYPE

EXPLANATION OF FEATURES

Page 11: PRODUCT CATALOGUE 2016 - zagzoog.com · • Note : Specifications are based on the following conditions. Cooling (SASO2681.T1) : Indoor temperature of 27°CDB / 19°CWB, and outdoor

• Note : Specifications are based on the following conditions. Cooling (SASO2681.T1) : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. Cooling (SASO2681.T3) : Indoor temperature of 29°CDB / 19°CWB, and outdoor temperature of 46°CDB / 24°CWB.• The protective function might work when using it in environment out of the temperature range mentioned above.• The maximum current is the maximum value when operated within the operation range.

SPECIFICATIONS

V/Ø/Hz

WBtu/h

WA

Btu/hWI/h(pints/h)

WBtu/h

WA

Btu/hWA

m3/hmm

kg(lbs)mm

kg(lbs)

Model Name

Indoor unit(High)

Indoor unit

Outdoor unit

Indoor unitOutdoor unit

60/1/2304

7,06024,1002,63011.69.16

2.9(5.1)

5,80019,8003,13014.06.3318

1,060455×670×710

63(137)

AXSS24FHTB

60/1/2305

5,28018,0001,810

8.19.94

2.0(3.5)

4,57015,6002,180

9.87.1613

940455×670×710

56(123)

AXSS18FHTA

Power SourceEnergy LabelCooling (T1 condition)

Capacity

Input PowerCurrentEERMoisture Removal

Cooling (T3 condition)

Capacity

Input PowerCurrentEER

Max. Running Current (Cooling)Airflow Rate

DimensionsH×W×D

Weight

11

Cooling

AXSS24FHTB

Cooling

AXSS18FHTA

WhiteFront Panel Colour

Energy saving and high performance are realized even at high outdoor temperature by using new refrigerant R410A and mounting

large heat exchanger and new efficient rotary compressor.

R410A

Optional parts

WINDOW TYPE

Wired Remote ControllerUTY-RNNGM

Communication KitUTY-XCBXZ3(for 30/36)

External Connect KitUTY-XWZXZ5(for 30/36)

For WALL MOUNTED TYPE

Wide PanelUTG-AKXA-W

IR Receiver UnitUTY-LBTGC

Wired Remote ControllerUTY-RNRGZ1

Panel SpacerUTG-BKXA-W

Air Outlet Shutter PlateUTR-YDZK

External Input and Output PCBUTY-XCSX

External Input and Output PCB BoxUTZ-GXRA

External Connect KitUTY-XWZXZG

For CASSETTE TYPE

Communication KitUTY-TWRXZ1

Insulation for High HumidityUTZ-KXRA

Panel spacer

242 mmIndoor unit950

Panel 600(mm)

600

Remote Sensor UnitUTY-XSZX

Long Life FilterUTD-LF25NA(for 18/25)

UTD-LFNA(for 40/50)UTD-LFKA(for 60)

Flange (Round)UTD-RF204(for 18/25)

Flange (Square)UTD-SF045T(for 18/25)

Drain Pump UnitUTZ-PX1NAA(for 40/50/60)

Drain Pump UnitUTZ-PX1NBA(for 18/25)

External Input and Output PCBUTY-XCSX(for 60)

External Input and Output PCB BracketUTZ-GXNA(for 60)

External Connect KitUTY-XWZXZG(for 60)

External Connect SetUTD-ECS5A(for 18/25/40/50)

For DUCT TYPE

Page 12: PRODUCT CATALOGUE 2016 - zagzoog.com · • Note : Specifications are based on the following conditions. Cooling (SASO2681.T1) : Indoor temperature of 27°CDB / 19°CWB, and outdoor

Distributed by:

•“ ” is a worldwide trademark or registered trademark of FUJITSU GENERAL LIMITED in Japan and other countries or areas.•The colors may be different from the actual colors because this catalog is printed matter.•Specifications and design subject to change without notice for further improvement. Please check with your dealer.

Copyright© 2013-2015 Fujitsu General Limited. All rights reserved. 3MGS06-1602EA

Fujitsu General (Shanghai) Co., Ltd.

ISO 9001Certified number: 01 100 79269

ISO 14001Certified number: CNBJ311153-UK

Fujitsu General (Thailand) Co., Ltd.

ISO 9001Certified number: 01 100 89394

ISO 14001Certified number: 01 104 9245/01

E-Mail: [email protected]