All rights reservedcSpecifications, designs and other content appearing in this brochure are current as of August 2017 but subject to change without notice.
Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation.
Use only those parts and accessories supplied or specified by Daikin.
Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
PCXSPH1732A
6
Dealer
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,Kita-ku, Osaka, 530-8323 Japan.
Head office:
Lot 60334, Persiaran Bukit Rahman Putra 3,Taman Perindustrian Bukit Rahman Putra,47000 Sungai Buloh, Selangor Darul Ehsan, Malaysiawww.daikinmalaysia.com
Outdoor Unit
Capacity 50 60kW 140125
FCRN50AXVLRR50AGXVL
FCRN60AXVLRR60AGXVL
FCRN71AXVLRR71AGXVL
FCRN100AXVLRR100AGXVL
FCRN125AXVL9RR125AGXTL9
FDMRN125AXVL9RR125AGXTL9
FDMRN140AXVL9RR140AGXTL9
RR50AGXVL RR60AGXVL RR71AGXVL RR100AGXVL
Ceiling Cassette Type(3x3)
Duct Connection Standard Static Pressure Type
Ceiling SuspendedType
Floor StandingType
Outdoor Unit
The solution for light commercial sectorProviding the ideal solution for all kinds of small commercial space such as shops, restaurant and small offices. The Sky Air series offers a complete comfort solution that puts you in total control.
Indoor unitOutdoor unit
FDMRN50DXV1RN50CAXV1
FHRN50DXV1RN50CAXV1
FDMRN60DXV1RN60CAXV1
FHRN60DXV1RN60CAXV1
FHRN140AXVLRR140AGXVL
FDMRN50AXVLRR50AGXVL
Indoor unitOutdoor unit
FVRN125AXVL9RR125AGXTL9
FVRN140AXVL9RR140AGXTL9
RR140AGXTL9RR125AGXTL9
Indoor unitOutdoor unit
Indoor unitOutdoor unit
01 02
FDMRN60AXVLRR60AGXVL
FDMRN71AXVLRR71AGXVL
FDMRN100AXVLRR100AGXVL
FHRN100AXVLRR100AGXVL
FHRN140AXVL9RR140AGXTL9
71 100
FVRN71AXVLRR71AGXVL
FVRN100AXVLRR100AGXVL
Wired controller:BRC51A62
COMFORT CLEANLINESS WORK & SERVICING CONTROL FEATURES OPTIONS OTHERS
Wireless controller:BRC52A62
3x3: FCRN50/60/71/100AXVL, 125AXVL9
Aut
o sw
ing
Sw
ing
patt
ern
Sw
itcha
ble
fan
spee
d
Pro
gram
me
“Dry
”
Two
sele
ctab
le te
mpe
ratu
rese
nsor
Tim
er s
elec
tor
Wee
kly
sche
dule
d tim
er
Was
habl
e sa
rane
t filte
r
Dra
in p
ump
mec
hani
sm
Pre
-cha
rged
for
up to
7.5
m
Sel
f dia
gnos
is
Aut
o ra
ndom
res
tart
Ext
erna
l com
man
d co
ntro
lus
ing
BA
G
Ant
i cor
rosi
on tr
eate
dhe
at e
xcha
nger
s
Fres
h-ai
r in
take
kit
Gro
up c
ontr
ol b
yN
etw
ork
Inte
rface
Mod
ule
(NIM
)
03 04
4-way air flowThis unit promotes even air distribution covering every corner of the room by combining 4-ways air discharge and large discharge area.
Fine square panelsPanel size is same for all models. It is easy to maintain a neat appearance when multiple units are installed.
Two selectable temperature sensorsBoth indoor unit and wired remote controller (option) contain temperature-sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature must be set during commissioning by the technicians.* Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room.** Wireless remote controller does not have a temperature-sensor.
* optional * supplied with panel
950mm
950mm
Compact body and quiet operationIndoor units as an aerodynamically designed Diffuser Turbo Fan.
Optimal comfort and convenience assured by air discharge modes (FCRN series only)To increase the comfort level of the air conditioned area, the system is built-in with 3 different types of air flow pattern to suit different requirements.
The default setting for air swing pattern is 1. The air swing pattern can be selected through the wireless remote control.
Draft resistance has been reduced by incorporating into a single unit, an impeller and a diffuser to control air flow inside the unit. The Diffuser Turbo Fan is both quiet during operation and compact.
*1 *1
*1 Applicable when wired controller is used.
Air direction in ceiling soiling prevention settingRecommended for location with light colour ceiling that must be
kept spotless.
3Air direction in draft prevention setting
Select this setting to eliminate direct drafts which can lead to
discomfort.
2Air direction in
standard settingFor gentle drafts.
1
3x3:
Ceiling CassetteType
05 06
Self-diagnosis functionThis intelligent feature helps to detect faults or malfunctioning in the system and give user a warning by blinking of the LED light or display error code on wired controller.
Quick and easy to installJust 246mm high. Installable in tight ceiling spaces.
All models can be installed without using lifter because of the light weight.
*246mm
* 246mm high with FCRN50/60/71* 288mm high with FCRN125/140
Detachable cornerFor the ease and flexibility of installation, this unit is designed with 4 detachable corners where installer is able to fit their hand in to adjust hanging hook and perform drain leakage check.
Position of connecting pipe and drain hoseIn order to create more space for installer to work on connection pipe of indoor unit, the connection pipe of gas and liquid are located further from each other and purposely not align to hanging hook.To enhance the convenience of installation, drain hose location is relocated to another side of cassette unit (not same side with connection pipe).
Easy accessible control boxControl box of this unit can be accessed directly from the intake grille for ease of installation and servicing process.
Drain pump is equipped as standard accessory with 700mm liftThis unit comes with a condensate water drain pump which can pump water up to 700mm higher from drain pipe outlet. Safety float is incorporated to monitor water level.
Panel-hook mechanismThis feature enables the installer to work with both hands as the panel can be hung on the unit.
Switchable fan speedHigh/Medium/Low/Quiet
High setting provides maximum reach while low setting minimises drafts.
Timer selectorOperation starts when the preset time of the ‘on’ timer elapses and stops when the preset time of the ‘off’ timer elapses.
Powerful operationNew powerful operation boosts airflow to maximum volume for a 20-minute period with highest fan speed. After this, the unit automatically returns to its previous settings.
Indoor unit on/off switchThe unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged.
Easier to maintainThe condition of the drain pan and drain water can be checked by removing the drain plug and intake grille.
Simple step to change fan motor• Without removing panel, it can be easily accessed and service to fan motor• Reduced troubleshooting and servicing time• Simple steps: control box fan cover blower fan fan motor
Extra protectionThis unit covered with insulation material acts as extra protection when installed under very high humidity environment to prevent condensation.
Easy installation
Fresh air intake kitUsing this kit*, a duct can be fitted to increase the intake of outdoor air.
Knock-out holeThe built-in knock-out hole are available for fresh air intake or branch duct.
Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally.
Options required for specific operating environments
Easy maintenance
700mm
Just open theintake grille!
Drain plug
FDMRN50/60/71/100AXVL, 125/140AXVL9(standard static)
07 08
Thin, lightweight indoor unit makes delivery and installation easyWith a height of only 261mm, installation is possible even in buildings with narrow ceiling spaces.
Flexibility in system designThe unit offers fan motor that can operate up to 3 speeds, thus providing choices of external static pressure for designing ducting system.
Double protection drainage systemThe primary drain pan is designed with high thermal insulation material and moulded in gradient for better condensate water drainage. The extra secondary drain pan “built in” to the standard unit offers extra protection against possible water leaking problems.
Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)When air conditioning two rooms simultaneously, the air discharged into each room must be circulated back to the air conditioner. To achieve this, a ventilation duct should be installed for each room or one of the indicated ventilation grilles should be installed on the partitioning wall or under the door between the rooms.
COMFORT CLEANLINESS WORK & SERVICING CONTROL FEATURES OTHERS
Sw
itcha
ble
fan
spee
d
Pro
gram
me
“Dry
”
Two
sele
ctab
le te
mpe
ratu
rese
nsor
Tim
er s
elec
tor
Wee
kly
sche
dule
d tim
er
Was
habl
e sa
rane
t filte
r
Pre
-cha
rged
for
up to
7.5
m
Sel
f dia
gnos
is
Aut
o ra
ndom
res
tart
Ext
erna
l com
man
d co
ntro
lus
ing
BA
G
Ant
i cor
rosi
on tr
eate
dhe
at e
xcha
nger
s
Gro
up c
ontr
ol b
yN
etw
ork
Inte
rface
Mod
ule
(NIM
)
*1 *1
*1 Applicable when wired controller is used.
Wired controller:BRC51A62
Wireless controller:BRC52A62
* supplied with unit * optional
261mm
Primary drain panPolystyrene (PS) withHigh Impact Polystyrene(HIPS) cover
Secondary drain panwith insulation
Switchable fan speedHigh/Medium/Low
High setting provides maximum reach while low setting minimises drafts.
Two selectable temperature sensorsBoth indoor unit and wired remote controller (option) contain temperature-sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature must be set during commissioning by the technicians.* Temperature-sensor on indoor unit must be used when the air
conditioner is controlled from another room.** Wireless remote controller does not have a temperature-sensor.
Duct Connection Standard Static Pressure Type
COMFORT CLEANLINESS WORK & SERVICING CONTROL FEATURES OTHERS
FHRN100AXVL
Sw
itcha
ble
fan
spee
d
Pro
gram
me
“Dry
”
Two
sele
ctab
le te
mpe
ratu
rese
nsor
Tim
er s
elec
tor
Wee
kly
sche
dule
d tim
er
Was
habl
e sa
rane
t filte
r
Pre
-cha
rged
for
up to
7.5
m
Sel
f dia
gnos
is
Aut
o ra
ndom
res
tart
Ext
erna
l com
man
d co
ntro
lus
ing
BA
G
Ant
i cor
rosi
on tr
eate
dhe
at e
xcha
nger
s
Gro
up c
ontr
ol b
yN
etw
ork
Inte
rface
Mod
ule
(NIM
)
09 10
Far and high air flowFar air flow distance with high air flow ensuring the spaces of the room to be cooled down rapidly to the set temperature.
Two selectable temperature sensorsBoth indoor unit and wired remote controller (option) contain temperature-sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature must be set during commissioning by the technicians.* Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room.** Wireless remote controller does not have a temperature-sensor.
*1 *1
*1 Applicable when wired controller is used.
Wired controller:BRC51A62
Wireless controller:BRC52A62
* optional * supplied with unit
Switchable fan speedHigh/Medium/Low
High setting provides maximum reach while low setting minimises drafts.
Timer selectorOperation starts when the preset time of the ‘on’ timer elapses and stops when the preset time of the ‘off’ timer elapses.
Installation flexibility for freedom of designUniform height and depth. Compact design for small-capacity models to meet tighter dimensional constraints.
Easy-clean surfacesIt is easy to wipe dirt off the surfaces of the unit.
Ease of maintenanceFor all maintenance tasks, access is from bottom surface.
Easy Installation
Easy Maintenance
FHRN140AXVL9
Ceiling SuspendedType
FVRN71/100AXVL, 125/140AXVL9
11 12
Auto-swing modeThis unit uses its automatic horizontal swing louver to spread comfortable air flow to cool every corner of the room. Its vertical louvers are adjusted manually to match different interior spaces and partition as well as to avoid direct airflow.
User-friendly controlsThe unit comes with a stylish black control panel with white LED light for clear display. It comes with a keylock function to prevent setting change from unauthorised personnel.
Safety clipThe safety clip feature allows users to remove the washable saranet filter with ease during maintenance. At the same time, it also acts as a safety feature to prevent the users from reaching into the electrical and mechanical components.
Two selectable temperature sensorsBoth indoor unit and wired remote controller (option) contain temperature-sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature must be set during commissioning by the technicians.* Temperature-sensor on indoor unit must be used when the air
conditioner is controlled from another room.
** Wireless remote controller does not have a temperature-sensor
Piping
Floor standing unit
Wired controller:BRC51A62
Wireless controller:BRC52A62
* optional * supplied with unit
Manual setting ofvertical airflow louversAuto horizontal swing
Off state On state
Keylock function:Activation / deactivation of keylock by pressing “SWING” and “TURBO” together for 5 seconds
Keylock icon displayed when activated
White display lights up to indicate modes and temperature settings when switched on
Additionally, this unit is incorporated with infrared sensor for usage with wireless controller which is supplied with the unit. Thus, it can be controlled using wireless controller for greater flexibility.
Switchable fan speedHigh/Medium/Low
High setting provides maximum reach while low setting minimizes drafts.
Timer selectorOperation starts when the preset time of the ‘on’ timer elapses and stops when the preset time of the ‘off’ timer elapses.
Powerful operationNew powerful operation boosts airflow to maximum volume for a 20-minute period with highest fan speed. After this, the unit automatically returns to its previous settings.
Indoor unit on/off switchThe unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged.
Easy maintenance
Safety clip
Far air flowThe Daikin floor standing is able to achieve air flow distance as far as 25m (size 160) which is about the size of a basketball court.
2.44
1.22
0.00
V_r (m/s)Global
25m
Space for water drain pumpThere is a space in the unit below the fan that allows users to install an external condensate water pump.* The condensate water drain pump is separately purchased and field installed.
Condensatewater
drain pump
COMFORT CLEANLINESS WORK & SERVICING CONTROL FEATURES
Aut
o sw
ing
Sw
itcha
ble
fan
spee
d
Pro
gram
me
“Dry
”
Two
sele
ctab
le te
mpe
ratu
rese
nsor
Tim
er s
elec
tor
Wee
kly
sche
dule
d tim
er
Was
habl
e sa
rane
t filte
r
Pre
-cha
rged
for
up to
7.5
m
Sel
f dia
gnos
is
Aut
o ra
ndom
res
tart
Ext
erna
l com
man
d co
ntro
lus
ing
BA
G
Gro
up c
ontr
ol b
yN
etw
ork
Inte
rface
Mod
ule
(NIM
)
*1 *1
*1 Applicable when wired controller is used.
OTHERS
Ant
i cor
rosi
on tr
eate
dhe
at e
xcha
nger
s
Floor StandingType
Outdoor unit
1413
Wide inlet fan
Durability• The unit is covered with corrosion-proof galvanized steel to enhance its durability.• Heat exchange fins are provided with anti-corrosion treatment.
Wired controller BRC51A62 can directly be connected to the unit’s main board to start operating without extra setting or modification. It also has a built-in temperature sensor that enables temperature sensing closer to target area for improved comfort (no settings required to activate the handset temperature sensor).
Real time clock and day displayTemperature operate in ˚C and ˚FSwing functionQuiet function
Sleep functionOn/off switch
Turbo functionCool, Dry, Fan mode
Delay timer (1 or 2 hours)
Wireless controller BRC52A62
Wired controller BRC51A62
1
1
2
3
4
5
6
7
8
9
7-days programmable timer10
Low, Medium, High, Auto fan speed
11
“Glow-in-the-dark” on/off switch
Fan speed selection:Low, Medium, High, AutoTemperature setting: Up & down
Sleep mode function
Off timer setting
Selectable mode: Cool, Dry, FanTurbo function
Quiet function
1
2
3
4
5
7
8
9
On timer setting10
Real time clock11
2
6
789
11
10
3
4
5
1
2
3
5
6
789
10
11
4
Vertical auto-swing6
IR receiver on wired handsetreceived the signal
Signal sent fromwireless handset
Fitted with wide inlet fanFully shaped aerodynamic propellers are designed to push air with a large wing surface, providing both high blow volume and quiet operation with turbulence.
RR100AGXVLRR125/140AGXTL9
RR71AGXVLRR50/60AGXVL
Pre-charged for up to 7.5 metresModel Max. piping length, m Max. piping elevation, m
RR50A
RR60A
RR71A
RR100A
RR125A
RR140A
30
50
50
15
25
30
Controller
Simple system that provides flexibility of controls
Group control by Network Interface Module (NIM)
1615
Group control by NetworkInterface module (NIM)
For simultaneous control of up to 16 indoor units
For sequential control of 2 indoor units at alternate sequence of pre-set hour
Operation and surveillanceis carried out using the contact signal from the operation control box in the building surveillance (security) room.
Sequential control bySequential Network Interface Module (S-NIM)
Control by external command using BAG
Control Pattern Remote Controls
NIM NIM
S-NIM S-NIM
NIM NIM
BAG
BMS
The NIM group controls consist of:• Mainboard• Mainboard• Control panel (BRC51A62)• NIM controller• Communication bus
NIM utilizes master-slave configurations. One master can control up to 15 slave units in a group. The master unit operates in conjunction with a control panel. Any settings done via the control panel connected to the master overwrite the settings of its slave units. Slave units can be operated with or without control panel. If a slave unit is operating with a control panel, its settings can be changed without following its master’s.• DIP switch setting for group and unit address• Automatic detection of control panel• Error codes and error unit’s ID indication on control panel• Supported configurations of NIM:
MasterBRC51A62BRC52A62
Slave
Sequential control by Sequential Network Interface Module (S-NIM)Control two units of air conditioner in a master and slave system, operating at alternate sequence of preset hours (3/4/5/7/9/11/12 hours), controlled by a single BRC51A62 controller.The S-NIM controls consist of:• Mainboard• Control panel (BRC51A62)• S-NIM controller• Communication bus
The S-NIM is suitable in environment requiring 24-hours air conditioning, such as server room, room containing critical electronics equipment, laboratories, telecommunication towers, railway switching centre and 24-hours shoplets. It also extends the operating lifetime of existing air conditioning units.
When the operating unit is faulty, the standby unit automatically takes over. Other features of S-NIM:• Auto restart feature with last state settings.• Error indication via error code display on the control panel.• Pre-set operation hours via DIP switch.• Maximum point to point distance of 1000m.
NIM controller
ONOFF
After 3 hours
ON OFF
Preset SwitchingTime: 3 hours
S-NIM S-NIM
S-NIM S-NIM
Network controlsNetwork controls
BAG BAG
1817
Specification Specification
Rated cooling capacities are based on the following conditions: Indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length: 7.5m
50 60 71 100 125FCRN50AXVL FCRN60AXVL FCRN71AXVL FCRN100AXVL FCRN125AXVL9RR50AGXVL RR60AGXVL RR71AGXVL RR100AGXVL RR125AGXTL9
Btu/hr 18500 24000 29500 36000 48000kW 5.42 7.03 8.65 10.55 14.07W 1730 2400 3130 3700 5100A 7.9 11.0 14.3 16.8 14.8
W/W 3.13 2.93 2.76 2.85 2.76V/Ph/Hz 220/1/60 220/1/60 220/1/60 220/1/60 220/3/60
cfm 730/620/510/360 840/700/560/440 890/760/620/490 1120/1030/890/760 1120/1030/890/760dB(A) 39/35/33/30 41/38/36/34 43/40/38/37 48/45/41/37 49/46/42/38
Unit mm 246x840x840 246x840x840 246x840x840 288x840x840 288x840x840With decoration panel mm 301x950x950 301x950x950 301x950x950 343x950x950 343x950x950Unit kg 22 22 22 25 25Decoration panel kg 27 27 27 30 30
dB(A) 50 50 57 61 66mm 651x855x328 651x855x328 753x855x328 852x1030x400 852x1030x400kg 43 43 57 71 87
Liquid (Flare) Inch ø1/4" ø1/4" ø3/8" ø3/8" ø3/8"Gas (Flare) Inch ø1/2" ø5/8" ø5/8" ø5/8" ø5/8"
m 30 30 50 50 50m 15 15 25 30 30
50 60 71 100 125 140FDMRN50AXVL FDMRN60AXVL FDMRN71AXVL FDMRN100AXVL FDMRN125AXVL9 FDMRN140AXVL9
RR50AGXVL RR60AGXVL RR71AGXVL RR100AGXVL RR125AGXTL9 RR140AGXTL9Btu/hr 18500 23500 29000 36000 48000 56000
kW 5.42 6.89 8.50 10.55 14.07 16.41W 1730 2400 3330 4000 5520 6590A 7.9 11.0 15.3 18.2 15.6 19.5
W/W 3.13 2.87 2.55 2.64 2.55 2.49V/Ph/Hz 220/1/60 220/1/60 220/1/60 220/1/60 220/3/60 220/3/60
cfm 590/520/320 690/570/440 900/830/640 1250/980/780 1540/1280/1100 1580/1330/1180Pa 50 50 100 100 100 100
dB(A) 40/38/33 42/40/39 47/45/42 50/47/43 51/48/46 52/50/47mm 261x1065x411 261x1200x411 378x929x541 378x1045x541 378x1299x541 378x1499x541kg 24 26 42 44 50 56
dB(A) 50 50 57 61 66 66mm 651x855x328 651x855x328 753x855x328 852x1030x400 852x1030x400 852x1030x400kg 43 43 57 71 87 101
Liquid (Flare) Inch ø1/4" ø1/4" ø3/8" ø3/8" ø3/8" ø3/8"Gas (Flare) Inch ø1/2" ø5/8" ø5/8" ø5/8" ø5/8" ø3/4"
m 30 30 50 50 50 50m 15 15 25 30 30 30
Model Indoor unitOutdoor unit
Nominal cooling capacity
Nominal total input powerNominal running currentEER
Indoor unit
Airflow (H/M/L/Q)External static pressure (H/M/L)Sound pressure level (H/M/L)Dimensions (HxWxD)Machine weight
Outdoor unit
Sound pressure level
Max. Interunit piping lengthMax. Installation level difference
Dimensions (HxWxD)Machine weight
Piping connections
Power Supply
BC50F2XWA
Max. Interunit piping lengthMax. Installation level difference
Airflow (H/M/L/Q)Sound pressure level (H/M/L/Q)
Dimensions (HxWxD)
Machine weight
Sound pressure levelDimensions (HxWxD)Machine weight
Nominal running currentEERPower Supply
Indoor unit
Outdoor unit
Piping connections
Indoor unitOutdoor unitDecorative panel
Nominal cooling capacity
Nominal total input power
Model
Ceiling cassette 3x3
Duct connection standard static pressure type
71 100 125 140FVRN71AXVL FVRN100AXVL FVRN125AXVL9 FVRN140AXVL9RR71AGXVL RR100AGXVL RR125AGXTL9 RR140AGXTL9
Btu/hr 29000 36000 48000 56000kW 8.50 10.55 14.07 16.41W 3130 3800 5000 6240A 13.7 17.3 14.5 18.8
W/W 2.72 2.78 2.81 2.63V/Ph/Hz 220/1/60 220/1/60 220/3/60 220/3/60
cfm 675/625/530 1035/945/845 1035/935/835 1170/1085/985dB(A) 44/42/39 49/47/44 50/48/46 54/53/51mm 1850x600x270 1850x600x350 1850x600x350 1850x600x350kg 42 45 48 51
dB(A) 57 61 66 66mm 753x855x328 852x1030x400 852x1030x400 852x1030x400kg 57 71 87 101
Liquid (Flare) Inch ø3/8" ø3/8" ø3/8" ø3/8"Gas (Flare) Inch ø5/8" ø5/8" ø5/8" ø3/4"
m 50 50 50 50m 25 30 30 30
125 160Model Indoor unit FHRN125AXVL FHRN160AXVL
Outdoor unit RR125AGXVL RR160AGXTLNominal cooling capacity Btu/hr 35000 56000
kW 10,26 16,41Nominal total input power W 3800 6240Nominal running current A 17,3 18,8EER W/W 2,70 2,63Power Supply V/Ph/Hz 220/1/60 220/3/60Indoor unit Airflow (H/M/L) cfm 1107/999/751 1550/1380/1000
Sound pressure level (H/M/L) dB(A) 49/46/43 56/54/51Dimensions (HxWxD) mm 235x1903x680 285x1903x680Machine weight kg 52 70
Outdoor Sound pressure level dB(A) 61 66Dimensions (HxWxD) mm 852x1030x400 852x1030x400Machine weight kg 71 101
Liquid (Flare) Inch ø3/8" ø3/8"Gas (Flare) Inch ø5/8" ø3/4"
m 50 50m 30 30
Max. Interunit piping lengthMax. Installation level difference
Piping connections
Indoor unit
Airflow (H/M/L/Q)Sound pressure level (H/M/L)Dimensions (HxWxD)Machine weight
Outdoor unit
Piping connections
Max. Interunit piping lengthMax. Installation level difference
Sound pressure levelDimensions (HxWxD)Machine weight
EERPower Supply
Model Indoor unitOutdoor unit
Nominal cooling capacity
Nominal total input powerNominal running current
Floor standing
Ceiling suspended100 140
FHRN100AXVL FHRN140AXVL9RR100AGXVL RR140AGXTL9
Btu/hr 35000 56000kW 10.26 16.41W 3800 6240A 17.3 18.8
W/W 2.70 2.63V/Ph/Hz 220/1/60 220/3/60
cfm 1107/999/751 1550/1380/1000dB(A) 49/46/43 56/54/51mm 235x1903x680 285x1903x680kg 52 70
dB(A) 61 66mm 852x1030x400 852x1030x400kg 71 101
Liquid (Flare) Inch ø3/8" ø3/8"Gas (Flare) Inch ø5/8" ø3/4"
m 50 50m 30 30
Max. Interunit piping lengthMax. Installation level difference
Outdoor unit
Sound pressure levelDimensions (HxWxD)Machine weight
Piping connections
Nominal running currentEERPower Supply
Indoor unit
Airflow (H/M/L)Sound pressure level (H/M/L)Dimensions (HxWxD)Machine weight
Model Indoor unitOutdoor unit
Nominal cooling capacity
Nominal total input power