PCXSPH1732A - daikin.com.ph ·...

10
All rights reserved c Specifications, designs and other content appearing in this brochure are current as of August 2017 but subject to change without notice. Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation. Use only those parts and accessories supplied or specified by Daikin. Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. PCXSPH1732A 6 Dealer Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan. Head office: Lot 60334, Persiaran Bukit Rahman Putra 3, Taman Perindustrian Bukit Rahman Putra, 47000 Sungai Buloh, Selangor Darul Ehsan, Malaysia www.daikinmalaysia.com

Transcript of PCXSPH1732A - daikin.com.ph ·...

All rights reservedcSpecifications, designs and other content appearing in this brochure are current as of August 2017 but subject to change without notice.

Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation.

Use only those parts and accessories supplied or specified by Daikin.

Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.

If you have any enquiries, please contact your local importer, distributor and/or retailer.

PCXSPH1732A

6

Dealer

Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,Kita-ku, Osaka, 530-8323 Japan.

Head office:

Lot 60334, Persiaran Bukit Rahman Putra 3,Taman Perindustrian Bukit Rahman Putra,47000 Sungai Buloh, Selangor Darul Ehsan, Malaysiawww.daikinmalaysia.com

Outdoor Unit

Capacity 50 60kW 140125

FCRN50AXVLRR50AGXVL

FCRN60AXVLRR60AGXVL

FCRN71AXVLRR71AGXVL

FCRN100AXVLRR100AGXVL

FCRN125AXVL9RR125AGXTL9

FDMRN125AXVL9RR125AGXTL9

FDMRN140AXVL9RR140AGXTL9

RR50AGXVL RR60AGXVL RR71AGXVL RR100AGXVL

Ceiling Cassette Type(3x3)

Duct Connection Standard Static Pressure Type

Ceiling SuspendedType

Floor StandingType

Outdoor Unit

The solution for light commercial sectorProviding the ideal solution for all kinds of small commercial space such as shops, restaurant and small offices. The Sky Air series offers a complete comfort solution that puts you in total control.

Indoor unitOutdoor unit

FDMRN50DXV1RN50CAXV1

FHRN50DXV1RN50CAXV1

FDMRN60DXV1RN60CAXV1

FHRN60DXV1RN60CAXV1

FHRN140AXVLRR140AGXVL

FDMRN50AXVLRR50AGXVL

Indoor unitOutdoor unit

FVRN125AXVL9RR125AGXTL9

FVRN140AXVL9RR140AGXTL9

RR140AGXTL9RR125AGXTL9

Indoor unitOutdoor unit

Indoor unitOutdoor unit

01 02

FDMRN60AXVLRR60AGXVL

FDMRN71AXVLRR71AGXVL

FDMRN100AXVLRR100AGXVL

FHRN100AXVLRR100AGXVL

FHRN140AXVL9RR140AGXTL9

71 100

FVRN71AXVLRR71AGXVL

FVRN100AXVLRR100AGXVL

Wired controller:BRC51A62

COMFORT CLEANLINESS WORK & SERVICING CONTROL FEATURES OPTIONS OTHERS

Wireless controller:BRC52A62

3x3: FCRN50/60/71/100AXVL, 125AXVL9

Aut

o sw

ing

Sw

ing

patt

ern

Sw

itcha

ble

fan

spee

d

Pro

gram

me

“Dry

Two

sele

ctab

le te

mpe

ratu

rese

nsor

Tim

er s

elec

tor

Wee

kly

sche

dule

d tim

er

Was

habl

e sa

rane

t filte

r

Dra

in p

ump

mec

hani

sm

Pre

-cha

rged

for

up to

7.5

m

Sel

f dia

gnos

is

Aut

o ra

ndom

res

tart

Ext

erna

l com

man

d co

ntro

lus

ing

BA

G

Ant

i cor

rosi

on tr

eate

dhe

at e

xcha

nger

s

Fres

h-ai

r in

take

kit

Gro

up c

ontr

ol b

yN

etw

ork

Inte

rface

Mod

ule

(NIM

)

03 04

4-way air flowThis unit promotes even air distribution covering every corner of the room by combining 4-ways air discharge and large discharge area.

Fine square panelsPanel size is same for all models. It is easy to maintain a neat appearance when multiple units are installed.

Two selectable temperature sensorsBoth indoor unit and wired remote controller (option) contain temperature-sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature must be set during commissioning by the technicians.* Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room.** Wireless remote controller does not have a temperature-sensor.

* optional * supplied with panel

950mm

950mm

Compact body and quiet operationIndoor units as an aerodynamically designed Diffuser Turbo Fan.

Optimal comfort and convenience assured by air discharge modes (FCRN series only)To increase the comfort level of the air conditioned area, the system is built-in with 3 different types of air flow pattern to suit different requirements.

The default setting for air swing pattern is 1. The air swing pattern can be selected through the wireless remote control.

Draft resistance has been reduced by incorporating into a single unit, an impeller and a diffuser to control air flow inside the unit. The Diffuser Turbo Fan is both quiet during operation and compact.

*1 *1

*1 Applicable when wired controller is used.

Air direction in ceiling soiling prevention settingRecommended for location with light colour ceiling that must be

kept spotless.

3Air direction in draft prevention setting

Select this setting to eliminate direct drafts which can lead to

discomfort.

2Air direction in

standard settingFor gentle drafts.

1

3x3:

Ceiling CassetteType

05 06

Self-diagnosis functionThis intelligent feature helps to detect faults or malfunctioning in the system and give user a warning by blinking of the LED light or display error code on wired controller.

Quick and easy to installJust 246mm high. Installable in tight ceiling spaces.

All models can be installed without using lifter because of the light weight.

*246mm

* 246mm high with FCRN50/60/71* 288mm high with FCRN125/140

Detachable cornerFor the ease and flexibility of installation, this unit is designed with 4 detachable corners where installer is able to fit their hand in to adjust hanging hook and perform drain leakage check.

Position of connecting pipe and drain hoseIn order to create more space for installer to work on connection pipe of indoor unit, the connection pipe of gas and liquid are located further from each other and purposely not align to hanging hook.To enhance the convenience of installation, drain hose location is relocated to another side of cassette unit (not same side with connection pipe).

Easy accessible control boxControl box of this unit can be accessed directly from the intake grille for ease of installation and servicing process.

Drain pump is equipped as standard accessory with 700mm liftThis unit comes with a condensate water drain pump which can pump water up to 700mm higher from drain pipe outlet. Safety float is incorporated to monitor water level.

Panel-hook mechanismThis feature enables the installer to work with both hands as the panel can be hung on the unit.

Switchable fan speedHigh/Medium/Low/Quiet

High setting provides maximum reach while low setting minimises drafts.

Timer selectorOperation starts when the preset time of the ‘on’ timer elapses and stops when the preset time of the ‘off’ timer elapses.

Powerful operationNew powerful operation boosts airflow to maximum volume for a 20-minute period with highest fan speed. After this, the unit automatically returns to its previous settings.

Indoor unit on/off switchThe unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged.

Easier to maintainThe condition of the drain pan and drain water can be checked by removing the drain plug and intake grille.

Simple step to change fan motor• Without removing panel, it can be easily accessed and service to fan motor• Reduced troubleshooting and servicing time• Simple steps: control box fan cover blower fan fan motor

Extra protectionThis unit covered with insulation material acts as extra protection when installed under very high humidity environment to prevent condensation.

Easy installation

Fresh air intake kitUsing this kit*, a duct can be fitted to increase the intake of outdoor air.

Knock-out holeThe built-in knock-out hole are available for fresh air intake or branch duct.

Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally.

Options required for specific operating environments

Easy maintenance

700mm

Just open theintake grille!

Drain plug

FDMRN50/60/71/100AXVL, 125/140AXVL9(standard static)

07 08

Thin, lightweight indoor unit makes delivery and installation easyWith a height of only 261mm, installation is possible even in buildings with narrow ceiling spaces.

Flexibility in system designThe unit offers fan motor that can operate up to 3 speeds, thus providing choices of external static pressure for designing ducting system.

Double protection drainage systemThe primary drain pan is designed with high thermal insulation material and moulded in gradient for better condensate water drainage. The extra secondary drain pan “built in” to the standard unit offers extra protection against possible water leaking problems.

Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)When air conditioning two rooms simultaneously, the air discharged into each room must be circulated back to the air conditioner. To achieve this, a ventilation duct should be installed for each room or one of the indicated ventilation grilles should be installed on the partitioning wall or under the door between the rooms.

COMFORT CLEANLINESS WORK & SERVICING CONTROL FEATURES OTHERS

Sw

itcha

ble

fan

spee

d

Pro

gram

me

“Dry

Two

sele

ctab

le te

mpe

ratu

rese

nsor

Tim

er s

elec

tor

Wee

kly

sche

dule

d tim

er

Was

habl

e sa

rane

t filte

r

Pre

-cha

rged

for

up to

7.5

m

Sel

f dia

gnos

is

Aut

o ra

ndom

res

tart

Ext

erna

l com

man

d co

ntro

lus

ing

BA

G

Ant

i cor

rosi

on tr

eate

dhe

at e

xcha

nger

s

Gro

up c

ontr

ol b

yN

etw

ork

Inte

rface

Mod

ule

(NIM

)

*1 *1

*1 Applicable when wired controller is used.

Wired controller:BRC51A62

Wireless controller:BRC52A62

* supplied with unit * optional

261mm

Primary drain panPolystyrene (PS) withHigh Impact Polystyrene(HIPS) cover

Secondary drain panwith insulation

Switchable fan speedHigh/Medium/Low

High setting provides maximum reach while low setting minimises drafts.

Two selectable temperature sensorsBoth indoor unit and wired remote controller (option) contain temperature-sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature must be set during commissioning by the technicians.* Temperature-sensor on indoor unit must be used when the air

conditioner is controlled from another room.** Wireless remote controller does not have a temperature-sensor.

Duct Connection Standard Static Pressure Type

COMFORT CLEANLINESS WORK & SERVICING CONTROL FEATURES OTHERS

FHRN100AXVL

Sw

itcha

ble

fan

spee

d

Pro

gram

me

“Dry

Two

sele

ctab

le te

mpe

ratu

rese

nsor

Tim

er s

elec

tor

Wee

kly

sche

dule

d tim

er

Was

habl

e sa

rane

t filte

r

Pre

-cha

rged

for

up to

7.5

m

Sel

f dia

gnos

is

Aut

o ra

ndom

res

tart

Ext

erna

l com

man

d co

ntro

lus

ing

BA

G

Ant

i cor

rosi

on tr

eate

dhe

at e

xcha

nger

s

Gro

up c

ontr

ol b

yN

etw

ork

Inte

rface

Mod

ule

(NIM

)

09 10

Far and high air flowFar air flow distance with high air flow ensuring the spaces of the room to be cooled down rapidly to the set temperature.

Two selectable temperature sensorsBoth indoor unit and wired remote controller (option) contain temperature-sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature must be set during commissioning by the technicians.* Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room.** Wireless remote controller does not have a temperature-sensor.

*1 *1

*1 Applicable when wired controller is used.

Wired controller:BRC51A62

Wireless controller:BRC52A62

* optional * supplied with unit

Switchable fan speedHigh/Medium/Low

High setting provides maximum reach while low setting minimises drafts.

Timer selectorOperation starts when the preset time of the ‘on’ timer elapses and stops when the preset time of the ‘off’ timer elapses.

Installation flexibility for freedom of designUniform height and depth. Compact design for small-capacity models to meet tighter dimensional constraints.

Easy-clean surfacesIt is easy to wipe dirt off the surfaces of the unit.

Ease of maintenanceFor all maintenance tasks, access is from bottom surface.

Easy Installation

Easy Maintenance

FHRN140AXVL9

Ceiling SuspendedType

FVRN71/100AXVL, 125/140AXVL9

11 12

Auto-swing modeThis unit uses its automatic horizontal swing louver to spread comfortable air flow to cool every corner of the room. Its vertical louvers are adjusted manually to match different interior spaces and partition as well as to avoid direct airflow.

User-friendly controlsThe unit comes with a stylish black control panel with white LED light for clear display. It comes with a keylock function to prevent setting change from unauthorised personnel.

Safety clipThe safety clip feature allows users to remove the washable saranet filter with ease during maintenance. At the same time, it also acts as a safety feature to prevent the users from reaching into the electrical and mechanical components.

Two selectable temperature sensorsBoth indoor unit and wired remote controller (option) contain temperature-sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature must be set during commissioning by the technicians.* Temperature-sensor on indoor unit must be used when the air

conditioner is controlled from another room.

** Wireless remote controller does not have a temperature-sensor

Piping

Floor standing unit

Wired controller:BRC51A62

Wireless controller:BRC52A62

* optional * supplied with unit

Manual setting ofvertical airflow louversAuto horizontal swing

Off state On state

Keylock function:Activation / deactivation of keylock by pressing “SWING” and “TURBO” together for 5 seconds

Keylock icon displayed when activated

White display lights up to indicate modes and temperature settings when switched on

Additionally, this unit is incorporated with infrared sensor for usage with wireless controller which is supplied with the unit. Thus, it can be controlled using wireless controller for greater flexibility.

Switchable fan speedHigh/Medium/Low

High setting provides maximum reach while low setting minimizes drafts.

Timer selectorOperation starts when the preset time of the ‘on’ timer elapses and stops when the preset time of the ‘off’ timer elapses.

Powerful operationNew powerful operation boosts airflow to maximum volume for a 20-minute period with highest fan speed. After this, the unit automatically returns to its previous settings.

Indoor unit on/off switchThe unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged.

Easy maintenance

Safety clip

Far air flowThe Daikin floor standing is able to achieve air flow distance as far as 25m (size 160) which is about the size of a basketball court.

2.44

1.22

0.00

V_r (m/s)Global

25m

Space for water drain pumpThere is a space in the unit below the fan that allows users to install an external condensate water pump.* The condensate water drain pump is separately purchased and field installed.

Condensatewater

drain pump

COMFORT CLEANLINESS WORK & SERVICING CONTROL FEATURES

Aut

o sw

ing

Sw

itcha

ble

fan

spee

d

Pro

gram

me

“Dry

Two

sele

ctab

le te

mpe

ratu

rese

nsor

Tim

er s

elec

tor

Wee

kly

sche

dule

d tim

er

Was

habl

e sa

rane

t filte

r

Pre

-cha

rged

for

up to

7.5

m

Sel

f dia

gnos

is

Aut

o ra

ndom

res

tart

Ext

erna

l com

man

d co

ntro

lus

ing

BA

G

Gro

up c

ontr

ol b

yN

etw

ork

Inte

rface

Mod

ule

(NIM

)

*1 *1

*1 Applicable when wired controller is used.

OTHERS

Ant

i cor

rosi

on tr

eate

dhe

at e

xcha

nger

s

Floor StandingType

Outdoor unit

1413

Wide inlet fan

Durability• The unit is covered with corrosion-proof galvanized steel to enhance its durability.• Heat exchange fins are provided with anti-corrosion treatment.

Wired controller BRC51A62 can directly be connected to the unit’s main board to start operating without extra setting or modification. It also has a built-in temperature sensor that enables temperature sensing closer to target area for improved comfort (no settings required to activate the handset temperature sensor).

Real time clock and day displayTemperature operate in ˚C and ˚FSwing functionQuiet function

Sleep functionOn/off switch

Turbo functionCool, Dry, Fan mode

Delay timer (1 or 2 hours)

Wireless controller BRC52A62

Wired controller BRC51A62

1

1

2

3

4

5

6

7

8

9

7-days programmable timer10

Low, Medium, High, Auto fan speed

11

“Glow-in-the-dark” on/off switch

Fan speed selection:Low, Medium, High, AutoTemperature setting: Up & down

Sleep mode function

Off timer setting

Selectable mode: Cool, Dry, FanTurbo function

Quiet function

1

2

3

4

5

7

8

9

On timer setting10

Real time clock11

2

6

789

11

10

3

4

5

1

2

3

5

6

789

10

11

4

Vertical auto-swing6

IR receiver on wired handsetreceived the signal

Signal sent fromwireless handset

Fitted with wide inlet fanFully shaped aerodynamic propellers are designed to push air with a large wing surface, providing both high blow volume and quiet operation with turbulence.

RR100AGXVLRR125/140AGXTL9

RR71AGXVLRR50/60AGXVL

Pre-charged for up to 7.5 metresModel Max. piping length, m Max. piping elevation, m

RR50A

RR60A

RR71A

RR100A

RR125A

RR140A

30

50

50

15

25

30

Controller

Simple system that provides flexibility of controls

Group control by Network Interface Module (NIM)

1615

Group control by NetworkInterface module (NIM)

For simultaneous control of up to 16 indoor units

For sequential control of 2 indoor units at alternate sequence of pre-set hour

Operation and surveillanceis carried out using the contact signal from the operation control box in the building surveillance (security) room.

Sequential control bySequential Network Interface Module (S-NIM)

Control by external command using BAG

Control Pattern Remote Controls

NIM NIM

S-NIM S-NIM

NIM NIM

BAG

BMS

The NIM group controls consist of:• Mainboard• Mainboard• Control panel (BRC51A62)• NIM controller• Communication bus

NIM utilizes master-slave configurations. One master can control up to 15 slave units in a group. The master unit operates in conjunction with a control panel. Any settings done via the control panel connected to the master overwrite the settings of its slave units. Slave units can be operated with or without control panel. If a slave unit is operating with a control panel, its settings can be changed without following its master’s.• DIP switch setting for group and unit address• Automatic detection of control panel• Error codes and error unit’s ID indication on control panel• Supported configurations of NIM:

MasterBRC51A62BRC52A62

Slave

Sequential control by Sequential Network Interface Module (S-NIM)Control two units of air conditioner in a master and slave system, operating at alternate sequence of preset hours (3/4/5/7/9/11/12 hours), controlled by a single BRC51A62 controller.The S-NIM controls consist of:• Mainboard• Control panel (BRC51A62)• S-NIM controller• Communication bus

The S-NIM is suitable in environment requiring 24-hours air conditioning, such as server room, room containing critical electronics equipment, laboratories, telecommunication towers, railway switching centre and 24-hours shoplets. It also extends the operating lifetime of existing air conditioning units.

When the operating unit is faulty, the standby unit automatically takes over. Other features of S-NIM:• Auto restart feature with last state settings.• Error indication via error code display on the control panel.• Pre-set operation hours via DIP switch.• Maximum point to point distance of 1000m.

NIM controller

ONOFF

After 3 hours

ON OFF

Preset SwitchingTime: 3 hours

S-NIM S-NIM

S-NIM S-NIM

Network controlsNetwork controls

BAG BAG

1817

Specification Specification

Rated cooling capacities are based on the following conditions: Indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length: 7.5m

50 60 71 100 125FCRN50AXVL FCRN60AXVL FCRN71AXVL FCRN100AXVL FCRN125AXVL9RR50AGXVL RR60AGXVL RR71AGXVL RR100AGXVL RR125AGXTL9

Btu/hr 18500 24000 29500 36000 48000kW 5.42 7.03 8.65 10.55 14.07W 1730 2400 3130 3700 5100A 7.9 11.0 14.3 16.8 14.8

W/W 3.13 2.93 2.76 2.85 2.76V/Ph/Hz 220/1/60 220/1/60 220/1/60 220/1/60 220/3/60

cfm 730/620/510/360 840/700/560/440 890/760/620/490 1120/1030/890/760 1120/1030/890/760dB(A) 39/35/33/30 41/38/36/34 43/40/38/37 48/45/41/37 49/46/42/38

Unit mm 246x840x840 246x840x840 246x840x840 288x840x840 288x840x840With decoration panel mm 301x950x950 301x950x950 301x950x950 343x950x950 343x950x950Unit kg 22 22 22 25 25Decoration panel kg 27 27 27 30 30

dB(A) 50 50 57 61 66mm 651x855x328 651x855x328 753x855x328 852x1030x400 852x1030x400kg 43 43 57 71 87

Liquid (Flare) Inch ø1/4" ø1/4" ø3/8" ø3/8" ø3/8"Gas (Flare) Inch ø1/2" ø5/8" ø5/8" ø5/8" ø5/8"

m 30 30 50 50 50m 15 15 25 30 30

50 60 71 100 125 140FDMRN50AXVL FDMRN60AXVL FDMRN71AXVL FDMRN100AXVL FDMRN125AXVL9 FDMRN140AXVL9

RR50AGXVL RR60AGXVL RR71AGXVL RR100AGXVL RR125AGXTL9 RR140AGXTL9Btu/hr 18500 23500 29000 36000 48000 56000

kW 5.42 6.89 8.50 10.55 14.07 16.41W 1730 2400 3330 4000 5520 6590A 7.9 11.0 15.3 18.2 15.6 19.5

W/W 3.13 2.87 2.55 2.64 2.55 2.49V/Ph/Hz 220/1/60 220/1/60 220/1/60 220/1/60 220/3/60 220/3/60

cfm 590/520/320 690/570/440 900/830/640 1250/980/780 1540/1280/1100 1580/1330/1180Pa 50 50 100 100 100 100

dB(A) 40/38/33 42/40/39 47/45/42 50/47/43 51/48/46 52/50/47mm 261x1065x411 261x1200x411 378x929x541 378x1045x541 378x1299x541 378x1499x541kg 24 26 42 44 50 56

dB(A) 50 50 57 61 66 66mm 651x855x328 651x855x328 753x855x328 852x1030x400 852x1030x400 852x1030x400kg 43 43 57 71 87 101

Liquid (Flare) Inch ø1/4" ø1/4" ø3/8" ø3/8" ø3/8" ø3/8"Gas (Flare) Inch ø1/2" ø5/8" ø5/8" ø5/8" ø5/8" ø3/4"

m 30 30 50 50 50 50m 15 15 25 30 30 30

Model Indoor unitOutdoor unit

Nominal cooling capacity

Nominal total input powerNominal running currentEER

Indoor unit

Airflow (H/M/L/Q)External static pressure (H/M/L)Sound pressure level (H/M/L)Dimensions (HxWxD)Machine weight

Outdoor unit

Sound pressure level

Max. Interunit piping lengthMax. Installation level difference

Dimensions (HxWxD)Machine weight

Piping connections

Power Supply

BC50F2XWA

Max. Interunit piping lengthMax. Installation level difference

Airflow (H/M/L/Q)Sound pressure level (H/M/L/Q)

Dimensions (HxWxD)

Machine weight

Sound pressure levelDimensions (HxWxD)Machine weight

Nominal running currentEERPower Supply

Indoor unit

Outdoor unit

Piping connections

Indoor unitOutdoor unitDecorative panel

Nominal cooling capacity

Nominal total input power

Model

Ceiling cassette 3x3

Duct connection standard static pressure type

71 100 125 140FVRN71AXVL FVRN100AXVL FVRN125AXVL9 FVRN140AXVL9RR71AGXVL RR100AGXVL RR125AGXTL9 RR140AGXTL9

Btu/hr 29000 36000 48000 56000kW 8.50 10.55 14.07 16.41W 3130 3800 5000 6240A 13.7 17.3 14.5 18.8

W/W 2.72 2.78 2.81 2.63V/Ph/Hz 220/1/60 220/1/60 220/3/60 220/3/60

cfm 675/625/530 1035/945/845 1035/935/835 1170/1085/985dB(A) 44/42/39 49/47/44 50/48/46 54/53/51mm 1850x600x270 1850x600x350 1850x600x350 1850x600x350kg 42 45 48 51

dB(A) 57 61 66 66mm 753x855x328 852x1030x400 852x1030x400 852x1030x400kg 57 71 87 101

Liquid (Flare) Inch ø3/8" ø3/8" ø3/8" ø3/8"Gas (Flare) Inch ø5/8" ø5/8" ø5/8" ø3/4"

m 50 50 50 50m 25 30 30 30

125 160Model Indoor unit FHRN125AXVL FHRN160AXVL

Outdoor unit RR125AGXVL RR160AGXTLNominal cooling capacity Btu/hr 35000 56000

kW 10,26 16,41Nominal total input power W 3800 6240Nominal running current A 17,3 18,8EER W/W 2,70 2,63Power Supply V/Ph/Hz 220/1/60 220/3/60Indoor unit Airflow (H/M/L) cfm 1107/999/751 1550/1380/1000

Sound pressure level (H/M/L) dB(A) 49/46/43 56/54/51Dimensions (HxWxD) mm 235x1903x680 285x1903x680Machine weight kg 52 70

Outdoor Sound pressure level dB(A) 61 66Dimensions (HxWxD) mm 852x1030x400 852x1030x400Machine weight kg 71 101

Liquid (Flare) Inch ø3/8" ø3/8"Gas (Flare) Inch ø5/8" ø3/4"

m 50 50m 30 30

Max. Interunit piping lengthMax. Installation level difference

Piping connections

Indoor unit

Airflow (H/M/L/Q)Sound pressure level (H/M/L)Dimensions (HxWxD)Machine weight

Outdoor unit

Piping connections

Max. Interunit piping lengthMax. Installation level difference

Sound pressure levelDimensions (HxWxD)Machine weight

EERPower Supply

Model Indoor unitOutdoor unit

Nominal cooling capacity

Nominal total input powerNominal running current

Floor standing

Ceiling suspended100 140

FHRN100AXVL FHRN140AXVL9RR100AGXVL RR140AGXTL9

Btu/hr 35000 56000kW 10.26 16.41W 3800 6240A 17.3 18.8

W/W 2.70 2.63V/Ph/Hz 220/1/60 220/3/60

cfm 1107/999/751 1550/1380/1000dB(A) 49/46/43 56/54/51mm 235x1903x680 285x1903x680kg 52 70

dB(A) 61 66mm 852x1030x400 852x1030x400kg 71 101

Liquid (Flare) Inch ø3/8" ø3/8"Gas (Flare) Inch ø5/8" ø3/4"

m 50 50m 30 30

Max. Interunit piping lengthMax. Installation level difference

Outdoor unit

Sound pressure levelDimensions (HxWxD)Machine weight

Piping connections

Nominal running currentEERPower Supply

Indoor unit

Airflow (H/M/L)Sound pressure level (H/M/L)Dimensions (HxWxD)Machine weight

Model Indoor unitOutdoor unit

Nominal cooling capacity

Nominal total input power