North Fork Floating Surface Collector:Summary of Design and First 6 Months of Operation
PGE’s Clackamas River Hydro Project
Nick Ackerman
Portland General Electric
Willamette Science Review, 2016 1
![Page 2: North Fork Floating Surface Collector - pweb.crohms.orgpweb.crohms.org/tmt/documents/FPOM/2010/Willamette_Coordination... · Siting & Design: 3 Migrant Collector Spillway Exclusion](https://reader035.fdocuments.us/reader035/viewer/2022062600/5b5ae0de7f8b9aa30c8cfea8/html5/thumbnails/2.jpg)
Overview:
2
o Siting and Designo Hydraulic Evaluationo Operational Experienceo Pilot Fish Guidance Efficiency Test Results
![Page 3: North Fork Floating Surface Collector - pweb.crohms.orgpweb.crohms.org/tmt/documents/FPOM/2010/Willamette_Coordination... · Siting & Design: 3 Migrant Collector Spillway Exclusion](https://reader035.fdocuments.us/reader035/viewer/2022062600/5b5ae0de7f8b9aa30c8cfea8/html5/thumbnails/3.jpg)
Siting & Design:
3
Migrant Collector
Spillway Exclusion NetTainterGates
FSC and Exclusion Nets
Powerhouse Intakes
Tertiary Screen
![Page 4: North Fork Floating Surface Collector - pweb.crohms.orgpweb.crohms.org/tmt/documents/FPOM/2010/Willamette_Coordination... · Siting & Design: 3 Migrant Collector Spillway Exclusion](https://reader035.fdocuments.us/reader035/viewer/2022062600/5b5ae0de7f8b9aa30c8cfea8/html5/thumbnails/4.jpg)
Siting & Design – North Fork Dam:
4
o 54 MWo Hydraulic Head of 138 feeto Reservoir is 2.8 miles long and 735 feet wide in forebayo Forebay typically fluctuates < + 2 ft.
![Page 5: North Fork Floating Surface Collector - pweb.crohms.orgpweb.crohms.org/tmt/documents/FPOM/2010/Willamette_Coordination... · Siting & Design: 3 Migrant Collector Spillway Exclusion](https://reader035.fdocuments.us/reader035/viewer/2022062600/5b5ae0de7f8b9aa30c8cfea8/html5/thumbnails/5.jpg)
Siting & Design - FSC:
5
o 1,000 cfs pumped flow
o 18 submersible Flygt pumps
o Entrance is 17.3 feet wide by 20.3 feet deep
o No on board fish sampling facility
o Exclusion nets
o Design/build cost = $42 million
![Page 6: North Fork Floating Surface Collector - pweb.crohms.orgpweb.crohms.org/tmt/documents/FPOM/2010/Willamette_Coordination... · Siting & Design: 3 Migrant Collector Spillway Exclusion](https://reader035.fdocuments.us/reader035/viewer/2022062600/5b5ae0de7f8b9aa30c8cfea8/html5/thumbnails/6.jpg)
Siting & Design - FSC:
6
![Page 7: North Fork Floating Surface Collector - pweb.crohms.orgpweb.crohms.org/tmt/documents/FPOM/2010/Willamette_Coordination... · Siting & Design: 3 Migrant Collector Spillway Exclusion](https://reader035.fdocuments.us/reader035/viewer/2022062600/5b5ae0de7f8b9aa30c8cfea8/html5/thumbnails/7.jpg)
Hydraulic Evaluation:
7
o NMFS design criteria meto Entrance flow = 967 cfso Capture velocity = 6.3 fpso No hot spots
Facing downstream through
secondary screens
Flow at entrance (3.1 fps)
![Page 8: North Fork Floating Surface Collector - pweb.crohms.orgpweb.crohms.org/tmt/documents/FPOM/2010/Willamette_Coordination... · Siting & Design: 3 Migrant Collector Spillway Exclusion](https://reader035.fdocuments.us/reader035/viewer/2022062600/5b5ae0de7f8b9aa30c8cfea8/html5/thumbnails/8.jpg)
Operational Experience:
8
![Page 9: North Fork Floating Surface Collector - pweb.crohms.orgpweb.crohms.org/tmt/documents/FPOM/2010/Willamette_Coordination... · Siting & Design: 3 Migrant Collector Spillway Exclusion](https://reader035.fdocuments.us/reader035/viewer/2022062600/5b5ae0de7f8b9aa30c8cfea8/html5/thumbnails/9.jpg)
War on Debris:
9
Grizzly rack at FSC entrance
![Page 10: North Fork Floating Surface Collector - pweb.crohms.orgpweb.crohms.org/tmt/documents/FPOM/2010/Willamette_Coordination... · Siting & Design: 3 Migrant Collector Spillway Exclusion](https://reader035.fdocuments.us/reader035/viewer/2022062600/5b5ae0de7f8b9aa30c8cfea8/html5/thumbnails/10.jpg)
War on Debris:
10
Screen cleaning systems
![Page 11: North Fork Floating Surface Collector - pweb.crohms.orgpweb.crohms.org/tmt/documents/FPOM/2010/Willamette_Coordination... · Siting & Design: 3 Migrant Collector Spillway Exclusion](https://reader035.fdocuments.us/reader035/viewer/2022062600/5b5ae0de7f8b9aa30c8cfea8/html5/thumbnails/11.jpg)
War on Debris:
11
Cattle Guards
![Page 12: North Fork Floating Surface Collector - pweb.crohms.orgpweb.crohms.org/tmt/documents/FPOM/2010/Willamette_Coordination... · Siting & Design: 3 Migrant Collector Spillway Exclusion](https://reader035.fdocuments.us/reader035/viewer/2022062600/5b5ae0de7f8b9aa30c8cfea8/html5/thumbnails/12.jpg)
War on Debris:
12
![Page 13: North Fork Floating Surface Collector - pweb.crohms.orgpweb.crohms.org/tmt/documents/FPOM/2010/Willamette_Coordination... · Siting & Design: 3 Migrant Collector Spillway Exclusion](https://reader035.fdocuments.us/reader035/viewer/2022062600/5b5ae0de7f8b9aa30c8cfea8/html5/thumbnails/13.jpg)
War on Debris:
13
Juvenile sampling
facility
![Page 14: North Fork Floating Surface Collector - pweb.crohms.orgpweb.crohms.org/tmt/documents/FPOM/2010/Willamette_Coordination... · Siting & Design: 3 Migrant Collector Spillway Exclusion](https://reader035.fdocuments.us/reader035/viewer/2022062600/5b5ae0de7f8b9aa30c8cfea8/html5/thumbnails/14.jpg)
War on Debris:
14
![Page 15: North Fork Floating Surface Collector - pweb.crohms.orgpweb.crohms.org/tmt/documents/FPOM/2010/Willamette_Coordination... · Siting & Design: 3 Migrant Collector Spillway Exclusion](https://reader035.fdocuments.us/reader035/viewer/2022062600/5b5ae0de7f8b9aa30c8cfea8/html5/thumbnails/15.jpg)
Pilot Guidance Test:
15
Released 55 Wild Chinook Smolts outside of forebay
(0.4km from FSC)
Released Nov. 2nd
Fish Guidance
Efficiency = 0.873
Pr FSC = 0.917
Prolonged heavy spill
beginning on day 16
may have affected
FGE.
![Page 16: North Fork Floating Surface Collector - pweb.crohms.orgpweb.crohms.org/tmt/documents/FPOM/2010/Willamette_Coordination... · Siting & Design: 3 Migrant Collector Spillway Exclusion](https://reader035.fdocuments.us/reader035/viewer/2022062600/5b5ae0de7f8b9aa30c8cfea8/html5/thumbnails/16.jpg)
Record Downstream Migrant Counts:
16
Downstream Migrant Counts from 1958 – 2015:
• September 2015: Record count of Chinook juveniles
(3x previous record)
• October 2015: Record count of coho juveniles
• November 2015: Record count of coho juveniles
(4x previous record)
• November 2015: Record count of lamprey
macrothalmia
• November 2015: Record count of steelhead
juveniles
![Page 17: North Fork Floating Surface Collector - pweb.crohms.orgpweb.crohms.org/tmt/documents/FPOM/2010/Willamette_Coordination... · Siting & Design: 3 Migrant Collector Spillway Exclusion](https://reader035.fdocuments.us/reader035/viewer/2022062600/5b5ae0de7f8b9aa30c8cfea8/html5/thumbnails/17.jpg)
Acknowledgements
Sean Flak –PGE Engineer (formerly)
Tim Keller – PGE Construction Manager
Peter Christensen – R2 Resource Consultants, Inc.
Countless PGE Staff and contractors involved with design,
construction, and operation
17
![Page 18: North Fork Floating Surface Collector - pweb.crohms.orgpweb.crohms.org/tmt/documents/FPOM/2010/Willamette_Coordination... · Siting & Design: 3 Migrant Collector Spillway Exclusion](https://reader035.fdocuments.us/reader035/viewer/2022062600/5b5ae0de7f8b9aa30c8cfea8/html5/thumbnails/18.jpg)
Questions?
18
![Page 19: North Fork Floating Surface Collector - pweb.crohms.orgpweb.crohms.org/tmt/documents/FPOM/2010/Willamette_Coordination... · Siting & Design: 3 Migrant Collector Spillway Exclusion](https://reader035.fdocuments.us/reader035/viewer/2022062600/5b5ae0de7f8b9aa30c8cfea8/html5/thumbnails/19.jpg)
19
![Page 20: North Fork Floating Surface Collector - pweb.crohms.orgpweb.crohms.org/tmt/documents/FPOM/2010/Willamette_Coordination... · Siting & Design: 3 Migrant Collector Spillway Exclusion](https://reader035.fdocuments.us/reader035/viewer/2022062600/5b5ae0de7f8b9aa30c8cfea8/html5/thumbnails/20.jpg)
Operations:
20
Operation % of Time
Normal 85.4
Reduced Flow 2.0
Off 12.5