LVCB General Leaflet E 0803
description
Transcript of LVCB General Leaflet E 0803
Leader in Electrics & Automation
Electric Equipment
MCCB / MCB / MMS / ACB / MS / Mini-MC / EMPR / DMPR
Low Voltage Circuit Breakers & Contactors
● 2, 3 and 4 pole series up to 1600AF ●Rated ambient temperature at 40℃ calibrated for 50℃ available●CE marked according to IEC standard and UL approved MCCBs
are also available.
● 1, 2, 3 and 4 pole series up to 125AF●B, C and D Characteristics
● 2 and 4 pole series up to 63AF● Sensitivity up to 300mA●Overcurrent protection type available
Page 4
Page 8
Page 10
Page 12
● 3 and 4 pole series up to 800AF Mini-contactors available● AC/DC common use coil from 100AF● Thermal (Bimetallic) and electronic type overload relays are available● CE marked and UL approved
Page 14● 65, 85 and 100kA breaking capacity● High functional digital trip relays● CE marked
Page 18
ABS ABH ABE ABS ABH GBL(E) ABE5 10 5 10 25 85 5
2, 3 2, 3 2, 3 2, 3, 4 2, 3, 4 3 2, 3ABS32b ABH32b ABE52b ABS52b ABH52b ABE62bABS33b ABH33b ABE53b ABS53b ABH53b GBL53E ABE63b
ABS54b ABH54b
600 600 600 600 600 600 600250 250 250 250 250 - 250690 690 690 690 690 690 690
6 6 6 6 6 6 6
10 25 10 25 50 125 107.5 14 7.5 14 25 85 7.55 10 5 10 25 85 55 10 5 10 25 85 5
2.5 7.5 2.5 7.5 14 65/50 2.52.5 5 2.5 5 10 35 2.55 10 5 10 20 - 5
2.5 5 2.5 5 14 - 2.550 50 50 50 50 75 50A A A A A A A
8500 8500 8500 8500 8500 10000 85001500 1500 1500 1500 1500 5000 1500
fixedLSIA configuration
●
fixed fixed fixed fixed fixed
▲ ▲ ▲ ▲ ▲ ▲
● ● ● ● ● ● ●
● ● ● ● ● ● ●
● ● ● ● ● ● ●
● ● ● ● ● ● ●
● ● ● ● ● ● ●
● ● ● ● ● ● ●
● ● ● ● ● ● ●
● ● ● ● ● ● ●
● ● ● ● ● ● ●
- - - - - - -- - - - - - -- - - - - - -
0.45 0.45 0.45 0.45 0.7 - 0.450.65 0.65 0.65 0.65 1 1.7 0.65
- - - 0.85 1.2 - -
Molded case circuit breakers30AF to 225AF
4
Note): 1. ● applicable or available2. ▲ available as a separate breaker3. (3) Breaking capacity(at 415VAC) of
ABS32b 3A ABS33b 3A is 2.5kA
Table 1.
Frame Size(AF) 30 50 60
90×155×60 105×165×80 75×130×60
5, 10, 15,20, 30
(3), 5, 10,15, 20, 30
5, 10, 15, 20,30, 40, 50
15, 20, 3040, 50
6050Electronically adjustable :
(0.5-0.6-0.7-0.8-0.9-1.0) ×In
75×130×60 75×130×60
Frame TypeBreaking capacity(kA), Icu at 415VACNumber of polesType 2 pole
3 pole4 pole
Rated current (A)
Technical data conforming to IEC/EN60947-2Rated operational voltage(V), Ue(50/60Hz)Rated operational voltage(V), Ue(DC)Rated insulation voltage(V), Ui(50/60Hz)Rated impulse withstand voltage(kV), UimpUltimate breaking capacity(kA), Icu
AC 50/60Hz 220/240V380V415V440/460V480/500V600V
DC 125V250V
Service breaking capacity(%Icu), IcsCategory of useEndurance Mechanical(Number of operations) ElectricalType of trip unitThermal-magnetic releaseElectronic releasePre-alarm via LED Hydraulic-magnetic releaseMagnetic release only without thermal tripEarth leakage protection for 3 pole AccessoriesElectrical auxiliaries Auxiliary switch
Alarm switchShunt tripUndervoltage trip
External accessories Direct rotary handleExtended rotary handleTerminal shieldInsulation barrierRear connection Mechanical interlockPlug-in deviceMotor operator
Dimensions (W×H×Dmm) 3 pole breakerWeight(kg) 2 pole
3 pole4 pole
Derating chart : See tables See table 1 See table 1
Amb. Temp. -5℃℃ 0℃℃ 10℃℃ 20℃℃ 25℃℃ 30℃℃ 35℃℃ 40℃℃ 45℃℃ 50℃℃
Calibrated for 40℃℃ In=15 to 30A 111.9% 111.3% 110.0% 108.0% 106.6% 104.9% 102.7% 100.0% 96.8% 93.3%
In=40 to 100A 110.2% 109.8% 108.7% 107.0% 105.8% 104.3% 102.4% 100.0% 97.2% 94.0%
Calibrated for 50℃℃ In=15 to 30A 113.1% 112.5% 111.3% 110.0% 109.1% 108.0% 106.6% 104.9% 102.7% 100.0%
In=40 to 100A 111.2% 110.7% 109.8% 108.7% 108.0% 107.0% 105.8% 104.3% 102.4% 100.0%
ABS ABE ABS ABH GBN GBH GBL GBL(E) ABE ABS ABH10 10 25 35 35 50 85 85 18 25 35
2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4 3 2, 3, 4 2, 3, 4 2, 3, 4ABS62b ABE102b ABS102b ABH102b GBN102 GBH102 GBL102 ABE202b ABS202b ABH202bABS63b ABE103b ABS103b ABH103b GBN103 GBH103 GBL103 GBL103E ABE203b ABS203b ABH203bABS64b ABE104b ABS104b ABH104b GBN104 GBH104 GBL104 ABE204b ABS204b ABH204b
600 600 600 600 600 600 600 600 600 600 600250 250 250 250 250 250 250 - 250 250 250690 690 690 690 690 690 690 690 690 690 6906 6 6 6 6 6 6 6 6 6 6
25 25 50 65 50 85 125 125 35 50 6514 14 25 35 35 50 85 85 18 25 3510 10 25 35 35 50 85 85 18 25 3510 10 25 35 35 50 85 85 18 25 357.5 7.5 14 25 30/22 42/35 65/50 65/50 10 14 255 5 10 18 18 25 35 35 7.5 10 1810 10 20 25 - - - - 15 20 255 5 14 18 35 50 85 - 10 14 1850 50 50 50 75 75 75 75 50 50 50A A A A A A A A A A A
8500 8500 8500 8500 20000 20000 10000 10000 7000 7000 70001500 1500 1500 1500 10000 10000 5000 5000 1000 1000 1000
fixed fixed fixed fixed fixedLSIA configuration
●
fixed fixed▲
▲ ▲ ▲ ▲ ▲ ▲ ▲
● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ●
- - - - - - - - - - -- - - - - - - - - - -- - - - - - - - - - -
0.45 0.45 0.7 0.7 1.1 1.1 1.5 - 1.1 1.1 1.10.65 0.65 1.1 1.1 1.2 1.2 1.7 1.7 1.2 1.2 1.20.85 0.85 1.2 1.2 1.5 1.5 2.1 - 1.5 1.5 1.5
5
60 100 225
75×130×60 90×140×86 105×165×86 105×165×60
Adjustable-thermal, Fixed-magnetic
100, 125, 150, 175, 200, 22560 100Electronically adjustable :
(0.5-0.6-0.7-0.8- 0.9-1.0) ×In
5, 10, 15, 2030, 40, 50
60, 75, 100
15, 20, 30, 40, 5060, 75, 100
63, 80, 100Thermally adjustable ;
(0.8- 0.9-1.0) ×In
90×155×60
See table 1 See table 1 See table 3 See table 2 (table 4 for GBL type)
Table 2.Amb. Temp. -5℃℃ 0℃℃ 10℃℃ 20℃℃ 25℃℃ 30℃℃ 35℃℃ 40℃℃ 45℃℃ 50℃℃
Calibrated for 50℃℃In=16 to 25A 122.0% 120.0% 116.0% 112.0% 110.0% 108.0% 106.0% 104.0% 102.0% 100.0%In=32 to 100A 127.5% 125.0% 120.0% 115.0% 112.5% 110.0% 107.5% 105.0% 102.5% 100.0%
Table 3.Amb. Temp. -5℃℃ 0℃℃ 10℃℃ 20℃℃ 25℃℃ 30℃℃ 35℃℃ 40℃℃ 45℃℃ 50℃℃
Calibrated for 40℃℃ In=100 to 225A 114.3% 113.2% 110.6% 107.5% 105.8% 140.0% 102.0% 100.0% 97.9% 95.6%Calibrated for 50℃℃ In=100 to 225A 116.3% 115.4% 113.2% 110.6% 109.1% 107.5% 105.8% 104.0% 102.0% 100.0%
Mold case circuit breakers250AF to 1600AF
6
Note ;● applicable or available▲ available as a separate breaker
Table 4.
Amb. Temp. -5℃℃ 0℃℃ 10℃℃ 20℃℃ 25℃℃ 30℃℃ 35℃℃ 40℃℃ 45℃℃ 50℃℃Calibrated for 50℃℃ In=40 to 200A 127.5% 125.0% 120.0% 115.0% 112.5% 110.0% 107.5% 105.0% 102.5% 100.0%
In=250A 122.0% 120.0% 116.0% 112.0% 110.0% 108.0% 106.0% 104.0% 102.0% 100.0%
GBN GBH GBL GBL(E) ABE ABS ABH ABL35 50 85 85 25 35 50 85
2, 3, 4 2, 3, 4 2, 3, 4 3 2,3,4 2,3,4 2,3,4 2, 3, 4GBN202 GBH202 GBL202 ABE402b ABS402b ABH402b ABL402bGBN203 GBH203 GBL203 GBL203E ABE403b ABS403b ABH403b ABL403bGBN204 GBH204 GBL204 ABE404b ABS404b ABH404b ABL404b
250
600 600 600 600 600 600 600 600250 250 250 - 250 250 250 250690 690 690 690 690 690 690 690
6 6 6 6 6 6 6 6
50 85 125 125 35 50 85 12535 50 85 85 30 42 65 10035 50 85 85 25 35 50 85/50(Ics)35 50 85 85 25 35 50 85
30/22 42/35 65/50 65/50 18 25 35 6518 25 35 35 18 22 25 30- - - - - - - -- - - - 20 30 50 60
35 50 85 - 10 20 40 4075 75 75 75 100 100 50 50A A A A A A A A
10000 10000 10000 10000 4000 4000 4000 40005000 5000 5000 5000 1000 1000 1000 1000
fixed fixed fixed fixedLSIA configuration●
▲ ▲ ▲
▲ ▲ ▲ ▲
● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ●
● ● ● ● - - - -
● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ●
- - - - ● ● ● ●
- - - - - - - -- - - - - - - -
105×165×86 140×257×1131.5 1.5 1.5 - 5.2 5.2 5.2 5.21.7 1.7 1.7 1.7 6.2 6.2 6.2 6.22.1 2.1 2.1 - 7.8 7.8 7.8 7.8
Frame Size(AF) 250 400Frame TypeBreaking capacity(kA), Icu at 415VACNumber of polesType 2 pole
3 pole4 pole
Rated current (A)
Technical data conforming to IEC/EN60947-2Rated operational voltage(V), Ue(50/60Hz)Rated operational voltage(V), Ue(DC)Rated insulation voltage(V), Ui(50/60Hz)Rated impulse withstand voltage(kV), UimpUltimate breaking capacity(kA), Icu
AC 50/60Hz 220/240V380V415V440/460V480/500V600V690V
DC 125V250V
Service breaking capacity(%Icu), IcsCategory of useEndurance Mechanical(Number of operations) ElectricalType of trip unitThermal-magnetic releaseElectronic releasePre-alarm via LED Hydraulic-magnetic releaseMagnetic release only without thermal tripEarth leakage protection for 3 pole AccessoriesElectrical auxiliaries Auxiliary switch
Alarm switchShunt tripUndervoltage trip
External accessories Direct rotary handleExtended rotary handleTerminal shieldInsulation barrierRear connection Mechanical interlockPlug-in deviceMotor operator
Dimensions (W×H×Dmm) 3 pole breakerWeight(kg) 2 pole
3 pole4 pole
Derating chart : See tables
Electronicallyadjustable :
(0.5-0.6-0.7-0.8-0.9-1.0)×In
250, 300, 350, 400Interchangeable via rating plug between
250 and 300350 and 400
125, 160, 200, 250Thermally adjustable :
(0.8- 0.9-1.0) ×InSee table 4 See table 5
GBN(E) GBH(E) ABE ABS ABL GBN(E) GBH(E) ABS ABS(electronic trip) GBN(E)35 50 35 50 85 35 50 65 65 653 3 2, 3, 4 2, 3, 4 2, 3, 4 3 3 3, 4 3 3
ABE802b ABS802b ABL802bGBN403E GBH403E ABE803b ABS803b ABL803b GBN803E GBH803E ABS1003 ABS1203 ABS1203E GBN1603E
ABE804b ABS804b ABL804b ABS1004 ABS12041000 1200 1200 1600
600 600 600 600 600 600 600 600 600 600- - 250 250 250 - - 250 250 -
690 690 690 690 690 690 690 690 690 6906 6 6 6 6 6 6 6 6 8
50 85 50 100 125 50 85 100 100 -35 50 42 65 100 35 50 65 65 -35 50 35 50 85/50(Ics) 35 50 65 65 6530 42 35 50 85 30 42 65 65 4522 35 25 45 65 22 35 50 50 2218 25 22 25 30 18 25 45 45 -- - - - - - - - - 20- - 30 50 60 - - - - -- - 20 40 40 - - 40 - -
50 50 100 50 50 50 50 50 50 50A A A A A A A A A A
4000 4000 2500 2500 2500 2500 2500 2500 2500 100001000 1000 500 500 500 500 500 500 500 4000
fixed fixed fixedLSIA configuration LSIA configuration LSIA configuration ●
● ● ● ● ● ●
▲
▲ ▲ ▲ ●
● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● - - ●
- - - - - - - - - ●
● ● ● ● ● ● ● - - ●
● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● - - -- - - - - - - - - ●
- - - - - - - - - ●
- 11 11 11 - - - -7.4 11.5 11.5 11.5 11.5 19.4 19.4 23- 18.2 18.2 18.2 - 27 - -
7
Table 5.
Amb. Temp. -5℃℃ 0℃℃ 10℃℃ 20℃℃ 25℃℃ 30℃℃ 35℃℃ 40℃℃ 45℃℃ 50℃℃
Calibrated for 40℃℃ 110.0% 109.0% 107.0% 105.0% 104.0% 103.0% 101.5% 100.0% 98.5% 97.0%
Calibrated for 50℃℃ 113.0% 112.0% 110.0% 108.0% 107.0% 106.0% 104.5% 103.0% 101.5% 100.0%
400 800 1200 1600
140×257×113 210×400×105 210×350×142.5
Adjustable-thermal, Fixed-magnetic
210×280×113
400Electronically adjustable :
(0.5-0.6-0.7-0.8-0.9-1.0)×In
800Electronically adjustable :(0.5-0.6-0.7-0.8-0.9-1.0)×In
500, 600, 630, 700, 800Interchangeable via rating plug between
500 and 600, 500 and 630, 700 and 800Electronically adjustable :(0.5-0.6-0.7-0.8- 0.9-1.0)×In
See table 5
3kA at 230VAC 6kA at
400VAC6kA at
230/400VAC
1 changeover contact
6A at 240VAC, 3A at 415VAC
2A at 48VDC, 1A at 125VDC
Lug terminal
cable capacity 2.5㎟
9mm wide
Type BKP BKN
1A2A3A4A6A10A16A20A25A32A40A50A63A80A
100A125A
Auxiliary switch, AXOptional
Dimension See drawing 1 See drawing 2Characteristic curve See curve 1 See curve 1
Protection Overload and short circuit Overload and short circuitRated current 3,6,10,16,20,25,32A 1,2,3,4,6,10,16,20,25,32,40,50,63ACharacteristic B, C, D curve B, C, D curveNumber of poles 1p+N 1p, 1p+N, 2p, 3p, 3p+N, 4pBreaking capacity 1 pole 2~4 pole
Standard IEC 60898 IEC 60898Type of trip Thermal magnetic release Thermal magnetic releaseElectrical endurance 20000 operations 6000 operationsMount On 35mm DIN rail On 35mm DIN railWidth 9mm per pole 17.8mm per poleTerminal Lug type(cable up to 10㎟) Lug type(cable up to 25㎟)
Miniature circuit breakers1, 2, 3 and 4 pole series up to 125AF
8
Drawing 1 : Type BKP
17.8
8.9
60 82
60
37
455
45
68
(22)
(22)
(17)
Drawing 2 : Type BKN
5
37
4560
(14)
45
17.8
63
68
82
10kA at 400VAC
10kA at400VAC
10kA at 230/400VAC
10kA at 400VAC
BKN-b BKH
See drawing 3 See drawing 4See curve 1 See curve 1
Overload and short circuit Overload and short circuit1,2,3,4,6,10,20,25,32,40,50,63A 63, 80, 100, 125AB, C, D curve C, D curve1p, 1p+N, 2p, 3p, 3p+N, 4p 1p, 1p+N, 2p, 3p, 3p+N, 4p1 pole 2~4 pole 1 pole 2~4 pole
IEC 60898 IEC 60947-2Thermal magnetic release Thermal magnetic release8000 operations 6000 operationsOn 35mm DIN rail On 35mm DIN rail17.8mm per pole 27mm per poleLug type(cable up to 25㎟) Lug type(cable up to 50㎟)
9
Drawing 3 : Type BKN-b
17.8
(33)
(19)
4537
5 43.8
6860
65 82
Drawing 4 : Type BKH
Curve 1 : Type BKP, BKN, BKN-b, BKH, RKP
Residual current circuit breakers 2 and 4 pole series up to 63AF
10
Drawing 1 : Type RKP
35.6
8.9
8260
45
60
5
(22)
68
37
(22)
(17)
45
70
Drawing 2 : Type RKN
561
74
(13)45
36 45
22
72
68 82
36
68 82
1 3 5 N
2
1
24 6 N
N
N
Drawing 3 : Type KGR Drawing 4 : Type BKD
37
5
60
70
45
(10)
45
60
17.8
82
Drawing 5 : Type RKS
5523
18
18
Type RKP RKS RKNProtection Ground fault and overcurrent Ground fault and overcurrent Ground fault Ground faultRated current, In 3(C,D),6,10,16,20,25,32A(B,C,D curve) 6, 10, 16, 20, 25, 32A (B, C curve) 25, 32, 40, 63ARated residual current
Operating, I△n 30, 100, 300mA(non-adjustable) 30, 100mA (non-adjustable) 30, 100, 300mA(non-adjustable)Non-operating, I△no 0.5I△n 0.5I△n 0.5I△n
Number of poles 1P+N 1P+N 2, 4 poleRated voltage 230VAC 230VAC 230VAC(2p), 230/400VAC(4p)Residual current off-time ≤ 0.1 sec. ≤ 0.3s ≤ 0.1 sec.Standard IEC 61009 IEC 61009 IEC 61008Type of trip
Ground fault Electro-magnetic Electro-magnetic Electro-magneticOvercurrent Thermal-magnetic Thermal-magnetic N.A
Breaking capacity 3kA 10kAConditional short circuit capacity 6kA for In=25, 32, 40, 63AElectrical endurance 20000 operations ≤ 4000 operations 6000 operationsMount On 35mm DIN rail On 35mm DIN rail On 35mm DIN railWidth 9mm per pole 9mm per pole 18mm per poleTerminal Lug type(cable up to 10㎟) Lug type(cable up to 10㎟) Lug type(cable up to 35㎟)Dimension See drawing 1 See drawing 5 See drawing 2Characteristic curve See page 9 (curve 1)
11
Type BKDRated current, In 40, 50, 63, 80, 100, 125ANumber of poles 1p, 2p, 3p, 4pRated voltage 230/400VACStandard IEC 60947-3
Electrical 40, 50, 63A 20000 operationsendurance 80, 100, 125A 10000 operationsMount On 35mm DIN railWidth 17.8mm per poleTerminal Lug type(cable up to 50㎟)Dimension See drawing 4
32KGRb32KGRa
Curve 1 : Type 32KGRa, 32KGRb
Ground fault and overcurrent15, 20, 30A
15, 30mA(non-adjustable)0.5I△n2 pole110/220VAC≤ 0.03 sec.KS, JIS *(IEC61009)
ElectronicBimetallic1.5kA 2.5kA
6000 operationsOn 35mm DIN rail35mm Screw clamp type(cable up to 25㎟)See drawing 3See curve 1
Note) * IEC61009 standard is applicable for 32KGRa only.
12
Manual motor startersQuick selection table ... IEC rating
220V 220V240V 415V 460V 525V 690V 240V 415V 460V 525V 690V
230V 400V 440V 500V 600V 230V 400V 440V 500V 600V
Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics
100 100 100 100 100 100 100 100 100 100100 100 100 100 100 100 100 100 100 100100 100 100 100 100 100 100 100 100 100100 100 100 100 100 100 100 100 100 100100 100 100 100 100 100 100 100 100 100100 100 100 100 100 100 100 100 3 3100 100 100 100 100 100 50 38 3 3100 100 100 100 50 38 15 11 3 3100 100 100 100 15 11 10 8 3 3100 100 100 100 15 11 10 8 3 3100 100 50 38 15 11 6 5 3 3100 100 50 38 10 8 6 5 3 350 38 20 15 10 8 6 5 3 340 30 15 11 8 6 6 5 3 340 30 15 11 8 6 6 5 3 330 22 15 11 6 4 5 4 3 3- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -
Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics
100 100 100 100 100 100 100 100 100 100100 100 100 100 100 100 100 100 100 100100 100 100 100 100 100 100 100 100 100100 100 100 100 100 100 100 100 100 100100 100 100 100 100 100 100 100 100 100100 100 100 100 100 100 100 100 100 100100 100 100 100 100 100 100 100 8 8100 100 100 100 100 100 100 100 8 8100 100 100 100 100 100 100 100 6 6100 100 100 100 50 38 50 38 6 6100 100 100 100 50 38 50 38 6 6100 100 100 100 50 38 42 32 6 6100 100 50 38 20 15 10 8 4 4100 100 50 38 20 15 10 8 4 4100 100 50 38 20 15 10 8 4 4100 100 50 38 20 15 10 8 4 4
- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -
0.160.250.40.63
11.62.54681013172226324050637590100
TypeCurrent adjustable type MMS-32S MMS-32HInstantaneous type - MMS-32HIBreaking capacity Standard High breakingHandle Type Toggle Rotary
Number of poles 3 3Rated operational voltage (Ue) Up to 690V Up to 690VRated frequency 50/60 Hz 50/60 HzRated insulation voltage (Ui) 690V 690VRated impulse voltage (Uimp) 6kV 6kVUtilization category IEC 60 947-2 (Breaker) Cat. A Cat. A
IEC 60 947-4 (Motor starter) AC 3 AC 3Mechanical endurance (Operating) 100,000 100,000Electrical endurance (Cycles) 100,000 100,000Max operating frequency per hour (Ope./h) 25 25Temperature compensation (Operation) -20 ~ +60℃ -20 ~ +60℃Instantaneous short circuit release 13 × Ie max. 13 × Ie max.Overload protection � �
Phase failure function � �
Trip indicating function × ×
Test function � �
Weight (g) 320 360Rated Rated Thermal releasebreaking operational Adjustmentcapacity
current (Ie)range
(kA) (A)0.1~0.160.16~0.250.25~0.40.4~0.630.63~11~1.6
1.6~2.52.5~44~65~86~109~1311~1714~2218~2622~3228~4034~5045~6355~7570~9080~100
Frame 32AF
13
220V 220V240V 415V 460V 525V 690V 240V 415V 460V 525V 690V
230V 400V 440V 500V 600V 230V 400V 440V 500V 600V
220V 220V240V 415V 460V 525V 690V 240V 415V 460V 525V 690V
230V 400V 440V 500V 600V 230V 400V 440V 500V 600V
- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -
100 100 100 100 15 12 10 8 4 3100 100 50 38 10 8 6 5 4 3100 100 25 19 10 8 6 5 4 350 38 25 19 10 8 6 5 4 350 38 25 19 10 8 6 5 4 350 38 25 19 10 8 6 5 4 350 38 25 19 10 8 6 5 4 350 38 25 19 10 8 6 5 4 350 38 25 19 10 8 6 5 4 3
- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -
- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -
100 100 100 100 50 38 50 38 6 5100 100 100 100 50 38 42 32 6 5100 100 50 50 50 38 12 9 5 5100 100 50 50 50 38 12 9 5 5100 100 50 50 35 27 12 9 5 5100 100 50 50 35 27 10 8 5 5100 100 50 50 35 27 10 8 5 5100 100 50 50 35 27 10 8 5 5100 100 50 50 35 27 10 8 5 5
- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -
- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -
100 100 50 38 40 30 25 19 10 8100 100 50 38 40 30 25 19 10 8100 100 50 38 40 30 25 19 10 8100 100 50 38 40 30 15 11 10 8100 100 50 38 40 30 15 11 6 5100 100 50 38 40 30 12 9 6 5100 100 50 38 40 30 12 9 6 5100 100 50 38 40 30 8 6 5 4100 100 50 38 40 30 8 6 5 4100 100 50 38 40 30 8 6 5 4
Icu Ics Icu Ics Icu Ics Icu Ics Icu IcsIcu Ics Icu Ics Icu Ics Icu Ics Icu IcsIcu Ics Icu Ics Icu Ics Icu Ics Icu IcsIcu Ics Icu Ics Icu Ics Icu Ics Icu Ics
- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -- - - - - - - - - -
100 100 100 100 50 38 35 27 12 9100 100 100 50 50 38 35 27 12 9100 100 100 50 50 38 35 27 12 9100 100 100 50 50 38 25 19 12 9100 100 100 50 50 38 20 15 12 9100 100 100 50 50 38 15 11 10 8100 100 100 50 50 38 15 11 8 6100 100 75 50 50 38 12 9 6 6100 100 75 50 50 38 12 9 6 6100 100 75 50 50 38 12 9 6 6
MMS-63S MMS-63H MMS-100S MMS-100H- MMS-63HI - MMS-100HI
Standard High breaking Standard High breakingRotary Rotary Rotary Rotary
3 3 3 3Up to 690V Up to 690V Up to 690V Up to 690V
50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz1,000V 1,000V 1,000V 1,000V
8kV 8kV 8kV 8kVCat. A Cat. A Cat. A Cat. AAC 3 AC 3 AC 3 AC 3
50,000 50,000 50,000 50,00025,000 25,000 25,000 25,000
25 25 25 25-20 ~ +60℃ -20 ~ +60℃ -20 ~ +60℃ -20 ~ +60℃
13 × Ie max. 13 × Ie max. 13 × Ie max. 13 × Ie max.� � � �
� � � �
× × � �
� � � �
1,000 1,000 2,200 2,200
63AF 100AF
Air circuit breakersRatings
14
Note) 1. Rated current of IEC standard2. Trip relay is divided into 50Hz and 60Hz. Please be careful when you order it.3. The generator protection relay is only available in OCR -III. 4. Ace-MEC ACB with interlock device can be a substitute for ATS5. For mainbody, only horizontal type is available. For cradle, vertical type is optional. In case of vertical type use of the horizontal type,
the user needs to apply the vertical adapter, The vertical type is standard for 4000/500AF.6. For 4000/5000AF, height is 455mm7. Slim type 4000AF, height is H:460, D:509
Type LBA-06������C LBA-08������C LBA-10������C LBA-13������C LBA-16������C
Rated current (In max) (A) 630, 400, 250 800 1000 1250 1600
Rated operating voltage (Ue) (V) 690 690 690 690 690
Rated insulation voltage (Ui) (V) 1000 1000 1000 1000 1000
Frequency (Hz) 50/60 50/60 50/60 50/60 50/60
Number of poles (P) 3,4 3,4 3,4 3,4 3,4
OCR-II For industry In max. × 1.0-0.9-0.8-0.7-0.6-0.5-0.4(7 Steps)
Setting current (In) (A) OCR-III
For industry In max. × 1.0-0.9-0.8-0.7-0.6-0.5-0.4(7 Steps)
For generator protection In max. × 1.0-0.9-0.8-0.7-0.6-0.5-0.4-0.3-0.2(9 Steps)
Rated current of (A) 630 800 1000 1250 1600
neutral pole
690V 50 50 50 50 50
600V 50 50 50 50 50
500V Under 65 65 65 65 65
Rated service(ICS) (kA) …% × ICU 100% 100% 100% 100% 100%
breaking capacity
690V 105 105 105 105 105
600V 105 105 105 105 105
500V Under 143 143 143 143 143
1 sec 65 65 65 65 65
Rated short-time capacity (ICW) (kA) 2 sec 40 40 40 40 60
3 sec 30 30 30 30 50
Maximum total breaking time 40 40 40 40 40
Closing time 80 80 80 80 80
Without maintenance 12000 12000 12000 12000 12000
With maintenance 20000 20000 20000 20000 20000
Without maintenance 3000 3000 3000 3000 3000
With maintenance 5000 5000 5000 5000 5000
Without maintenance 10000 10000 10000 10000 10000
Without maintenance 3000 3000 3000 3000 3000
Motor charging type 66/80 67/81 67/81 67/81 67/81
Manual charging type 63/77 64/78 64/78 64/78 64/78
26/30 26/30 26/30 26/30 26/30
Motor charging type 43/53 44/54 44/54 44/54 44/54
Manual charging type 40/50 41/51 41/51 41/51 41/51
Horizontal type Standard Standard Standard Standard Standard
Vertical type Option Option Option Option Option
Motor charging type Standard Standard Standard Standard Standard
Manual charging type Option Option Option Option Option
Draw-out type (mm) H: 435, D: 479 W(3P/4P) 350/435 350/435 350/435 350/435 350/435
Fixed type (mm) H: 410, D: 375 W(3P/4P) 345/430 345/430 345/430 345/430 345/430
Certificate & Approval KERI, CESI, KEMA
Rated breaking capacity (ICU)
(Sym) IEC 60947-2 AC
IEC 60947-2 AC
(kA)
(kA)
(ms)
(time)
(time)
Mechanical
Electrical
Mechanical
Electrical
Draw-out
type
Fixed type
Cradle only
Main body
(with cradle)
(kg)
Rated making capacity (ICm)
(peak)
Operating time ( t )
Life cycle
Weight
(3P/4P)
Bus-bar
Closing type
External
dimension
Connection type
ACB
ATS withACBs Note 4)
Note5)
Note2)
Note3)
15
Type LBA-20������C LBA-25������C LBA-32������C LBA-4S����EC LBA-40������C LBA-50������C
Rated current (In max) (A) 2000 2500 3200(3150) 4000 4000 5000
Rated operating voltage (Ue) (V) 690 690 690 690 690 690
Rated insulation voltage (Ui) (V) 1000 1000 1000 1000 1000 1000
Frequency (Hz) 50/60 50/60 50/60 50/60 50/60 50/60
Number of poles (P) 3,4 3,4 3,4 3,4 3,4 3,4
OCR-II For industry In max. ×1.0-0.9-0.8-0.7-0.6-0.5-0.4(7 Steps)
Setting current (In) (A) OCR-III
For industry In max. × 1.0-0.9-0.8-0.7-0.6-0.5-0.4(7 Steps)
For generator protection In max. ×1.0-0.9-0.8-0.7-0.6-0.5-0.4-0.3-0.2(9 Steps)
Rated current of (A) 2000 2500 3150 4000 2500 2500
neutral pole
690V 50 50 50 50 50 50
600V 65 65 65 65 85 85
500V Under 85 85 85 85 100 100
Rated service(ICS) (kA) …% ×ICU 100% 100% 100% 100% 100% 100%
breaking capacity
690V 105 105 105 105 105 105
600V 143 143 143 143 187 187
500V Under 187 187 187 187 220 220
1 sec 65 65 65 65 85 85Rated short-time
(ICW) (kA) 2 sec 60 60 60 60 65 65capacity
3 sec 60 60 60 60 65 65
Maximum total breaking time 40 40 40 40 40 40
Closing Time 80 80 80 80 80 80
Without maintenance 10000 10000 10000 10000 10000 10000
With maintenance 20000 20000 20000 20000 20000 20000
Without maintenance 3000 3000 3000 3000 3000 3000
With maintenance 5000 5000 5000 5000 5000 5000
Without maintenance 10000 10000 10000 - - -
Without maintenance 3000 3000 3000 - - -
Motor charging type 95/116 96/117 98/119 244/267 244/267
Manual charging type 92/113 93/114 95/116 240/263 240/263
35/43 35/43 36/44 125/140 125/140
Motor charging type 63/75 64/76 66/78 - 119/127 119/127
Manual charging type 60/72 61/73 63/75 - 115/123 115/123
Horizontal type Standard Standard Standard -
Vertical type Option Option Option Standard
Motor charging type Standard Standard Standard Standard Standard Standard
Manual charging type Option Option Option Option Option Option
Draw-out type (mm) H: 435, D: 479 W(3P/4P) 485/615 485/615 485/615 485/615 960/1090 960/1090
Fixed type (mm) H: 410, D: 375 W(3P/4P) 480/610 480/610 480/610 - 870/1000 870/1000
Certificate & Approval KERI, CESI, KEMA KEMA KEMA, CCC
Rated breaking (ICU)
capacity (Sym) IEC 60947-2 AC
IEC 60947-2 AC
(kA)
(kA)
(ms)
(time)
(time)
Mechanical
Electrical
Mechanical
Electrical
Draw
-out
type
Fixed type
Cradle only
Main body
(with cradle)
(kg)
Rated making (ICm)
capacity (peak)
Operating time ( t )
Life cycle
Weight
(3P/4P)
Bus-bar
Closing type
External
dimension
Connection type
ACB
ATS with
ACBs Note 4)
Note5)
Note2)
Note3)
Note6) Note7)
Note1)
Standard offer in the fixed type
Standard offer in the draw-out type
New
Note 8) Slim type 4000A① The cubicle of High capacity low voltage cubicle can get the most suitable space(Dimension is 40% smaller than existing Ace-Mec ACB 4000A)② Current capacity of neutral line(N phase) is 100%③When the OCR-II is applied, only external input power is available.④ Only vertical type of plug in type is available.
Note 9) It is guaranteed by KEMA CB certificate.
Note 9) Note 9)
Note 8)
Air circuit breakersElectronic trip relays : OCR-II
16
Characteristics of protection
Deratings by ambient temperature● Ambient temperature: -5℃~±40℃ (Only applicable when the 24 hours average temperature is below ±35℃)● Altitude : Below 2000m● Environmental condition
-Below 85% in humidity with ±40℃maximum temperature-Within the flammable, ammonia and corrosive gas environment can not be used and stored(H2S≤0.01ppm, SO2≤0.01ppm, NH3≤a few ppm)
● Safekeeping temperature : -20℃~±60℃ below ±35℃ degree of 24 hours average temperature
Applicable current of braker in temperatureIn case of use of over 40℃ in ambient temperature, please refer to below table as adjusting the rated currents
40℃ 630 800 1,000 1,250 1,600 2,000 2,500 3,200 4,000 5,000
45℃ 630 800 1,000 1,250 1,600 2,000 2,500 3,200 4,000 5,000
50℃ 630 800 1,000 1,250 1,600 2,000 2,500 3,200 4,000 5,000
55℃ 630 800 1,000 1,250 1,550 2,000 2,450 3,000 3,900 4,850
60℃ 630 800 1,000 1,200 1,500 2,000 2,350 2,900 3,750 4,700
LBA-50LBA-40LBA-32LBA-25LBA-20LBA-16LBA-13LBA-10LBA-08LBA-06AmbienttemperatureType
IEC 60947-2(Standard temp:40℃
① Long-time delay pick-up current② Long-time delay tripping time③ Short-time delay pick-up current④ Short-time delay tripping time:I2t 0N (Operating characteristics inverse)I2t 0FF (Operating characteristics definite)
⑤ Instantaneous pick-up current⑥ Pre-alarm pick-up current⑦ Pre-alarm tripping time⑧Ground fault pick-up current⑨Ground fault trip time
Note 1) For type LN5 and LN6, please use Neutral CT (output: 5A) in case of using 3P ACB in 3phase 4wire circuit.Note 2) In case of short circuit accident, instantaneous operation time of OCR is under 15ms.Note 3) Inp is a function for neutral protection. It protects neutral phase in 4 pole ACB from over current.Note 4) LS6, LS5 : ①②③④⑤⑥⑦
LF6, LF5, LN6, LN6 : ①②③④⑤⑥⑦⑧⑨
Type 60Hz50Hz
ApplicationPossible number of ACB polesOperating voltageCommunication
Long-time delay (L)Short-time delay (S)
Operating characteristics Instantaneous time delay ( I )Ground fault (G)Pre-alarm (P)
Setting current (A) In = …× In Max
Continuous current (A) Ic = …× InLong-time delay(L) Trip current (A) IL = …× Ic(Error tolerance : ±10%) Trip time (sec) LTDShort-time delay(S) Trip current (A) Is = …× In(Error tolerance : ±15%) Trip time (sec) STDInstantaneous time delay(I) Trip current (A) li = …× In(Error tolerance : ± 20%) Trip time (sec) INST
Ground fault(G) Trip current (A)Ig = …× In Max
(Error tolerance : ±20%)Inp= …× In Max
Trip time (sec) GTDPre-alarm(P) Trip current (A) Ip = …× Ic(Error tolerance : ±10%) Trip time (sec) PAL = …× LTD
Classification Types and ratings of trip relaysLS6 LF6 LN6 Note1)
LS5 LF5 LN5 Note1)
For industry For industry For industry3, 4P 3,4P 3P
AC/DC 110V~220V AC/DC 110V~220V AC/DC 110V~220V- - -� � �
� � �
� � �
- � �
� � �
0.4-0.5-0.6-0.7-0.8-0.9-1.00.6-0.7-0.8-0.85-0.9-0.95-1.0
1.515-30-60-120-240-480
2-3-4-6-8-10-OFF0.05-0.1-0.2-0.3-0.4-0.5
4-6-8-10-12-16-OFF0.025 under Note2)
0.1-0.2-0.3-0.4-0.5-OFF0.5-1.0-OFF Note3)
0.1-0.3-0.5-0.7-1.0-1.5-3.00.7-0.8-0.9-0.95-1.0-OFF
0.5(setting Ip 1.0), Operating time : Half of the long time inverse time
17
OCR-III
Characteristics of protection① Long-time delay pick-up current
② Long-time delay tripping time
③ Short-time delay pick-up current
④ Short-time delay tripping time
⑤ Instantaneous pick-up current
⑥ Pre-alarm pick-up current
⑦ Pre-alarm tripping time
⑧Ground fault pick-up current
⑨Ground fault trip time
Note 1) In case of short circuit accident, instantaneous operation time of OCR is under 15ms.Note 2) N�6/5, P�6/5 : ①②③④⑤⑥⑦⑧⑨
C�6/5, M�6/5 : ①②③④⑤⑥⑦⑧⑨
Type 60Hz
50Hz
Application
Possible number Of ACB poles
1
Operating voltage 2
4
Communication
Communication protocol
Protocol
Transmission speed
Long-time delay(L)
Short-time delay(S)
Operating characteristics Instantaneous time delay (I)
Ground fault (G)
Pre-alarm (P)
Rated current (A) In = …× In Max.
Continuous current (A) Ic = …× In
Long-time delay(L)Trip current (A) IL = …× Ic
(Error tolerance : ±10%) Trip time (sec) LTD
Short-time delay(S) Trip current (A) Is = …× In
(Error tolerance: ±15%) Trip time (sec) STD
Instantaneous time delay(I) Trip current (A) li = …× In
(Error tolerance : ±15%)Trip time (sec) INST
Trip current (A) Ig = …× In Max.Ground fault(G)
(Error tolerance : ±20%)Trip time (sec) GTD
Pre-alarm(P) Trip current (A) Ip = …× Ic
(Error tolerance : ±10%) Trip time (sec) PAL = … x LTD
N�6 C�6 P�6 M�6
N�5 C�5 P�5 M�5
For industry For industry For generator protection For generator protection
3, 4P 3, 4P 3, 4P 3, 4P
AC/DC 110V/220V AC/DC 110V/220V AC/DC 110V/220V AC/DC 110V/220V
DC24V DC24V DC24V DC24V
DC48V DC48V DC48V DC48V
- � - �
- RS 485 - RS 485
- DNP 3.0 - DNP 3.0
- 9600 bps - 9600 bps
� � � �
� � � �
� � � �
� � � �
� � � �
�For industry: 0.4-0.5-0.6-0.7-0.8-0.9-1.0
�For generator protection: 0.2-0.3-0.4-0.5-0.6-0.7-0.8-0.9-1.0
0.6-0.65-0.7-0.75-0.8-0.85-0.9-0.95-1.0
1.5
�For industry : 15-20-25-30~465-470-475-480(Steps: 5sec)
�For generator protection: 1.5-2.0-2.5-3.0~46.5-47.0-47.5-48.0(Steps: 0.5sec)
1.5-2-3-4-5-6-7-8-9-10-no(Steps: 0.5)
0.05-0.06~0.49-0.5(Steps: 0.01sec)
�4000A under: 2-3-4-5-6-7-8-9-10-11-12-13-14-15-16-no(Steps: 1)
�5000A over: 2-3-4-5-6-7-8-9-10-11-12-no(Steps: 1)
0.025 under Note)
�3 pole: 0.2-0.3-0.4-0.5-0.6-0.7-0.8-0.9-10-no(Steps: 0.1)
�4 pole: 0.1-0.2-0.3-0.4-0.5-0.6-0.7-0.8-0.9-10-no(Steps: 0.1)
0.1-0.2-0.3~2.8-2.9-3.0 (Step: 0.1sec)
0.7-0.8-0.9-1.0
0.5(setting Ip 1.0)
Classification Types and ratings of trip relays
Contactors & Overload relays9 to 85A
18
2-poleSide mount
4-poleFront mount
2-poleFront mount
Types AC coil GMC-9 GMC-12 GMC-18 GMC-22 DC coil GMD-9 GMD-12 GMD-18 GMD-22
Ratings / IEC60947-4 kW A kW A kW A kW AAC1 25 25 40 40AC3 200/240V 2.5 11 3.5 13 4.5 18 5.5 22
380/440V 4 9 5.5 12 7.5 18 11 22500/550V 4 7 7.5 12 7.5 13 15 22690V 4 5 7.5 9 7.5 9 15 18
Ratings / UL508 hp A hp A hp A hp Acontinuous current 20 25 30 32single phase 115V 0.5 0.5 1 2
230V 1 2 3 3three phase 200V 2 3 5 7
230V 2 3 5 7.5460V 5 7.5 10 10575V 7.5 10 15 15
NEMA size 00 00 0 0
Types AC coil GMC-9/4 GMC-12/4 GMC-18/4 GMC-22/4DC coil GMD-9/4 GMD-12/4 GMD-18/4 GMD-22/4
AC1(A) 20 20 25 32
Additional auxiliary contacts
3-pole Contactors
9AFrame size 12A 18A 22A
4-pole Contactors
Overload Relays
Bimetallic styleType GT
Base for separate mount
Setting ranges (A)
DifferentialClass10A Non-differential (3-heater)
Non-differential (2-heater)Class 20 Differential
GTK-22GTH-22/3GTH-22
GTK-22/L
0.1 - 0.160.16 - 0.250.25 - 0.4
0.4 - 0.630.63 - 1
1 - 1.61.6 - 2.52.5 - 4
4 - 65 - 86 - 97 - 109 - 13
12 - 1616 - 22
Electronic styleType GMP
Class 1�30 adjustableSeparate mount type
GMP22
Setting ranges (A)
0.1 - 1.51 - 5
4.4 - 22
GT-22
19
Base for separate mount
Setting ranges(A) : 16 ~ 80A
Separate mountWiring by screw
GMP80
Setting ranges(A) : 5 ~ 60A
Separate mountWiring by CT tunnelGMP60
Setting ranges (A)4 - 20
8 - 40
GMC-32 GMC-40 GMC-50 GMC-65 GMC-75 GMC-85 GMD-32 GMD-40 GMD-50 GMD-65 GMD-75 GMD-85
kW A kW A kW A kW A kW A kW A50 60 80 100 110 135
7.5 32 11 40 15 55 18.5 65 22 75 25 8515 32 18.5 40 22 50 30 65 37 75 45 85
18.5 28 22 32 30 43 33 60 37 64 45 7518.5 20 22 23 30 28 33 35 37 42 45 45hp A hp A hp A hp A hp A hp A
45 50 70 80 90 1002 3 3 5 5 7.55 5 7.5 10 15 15
7.5 10 10 15 20 2510 10 15 20 25 3020 25 30 40 50 5020 25 30 40 50 501 1 2 2 2 3
GMC-32/4 GMC-40/4 GMC-50/4 GMC-65/4 GMC-75/4 GMC-85/4 GMD-32/4 GMD-40/4 GMD-50/4 GMD-65/4 GMD-75/4 GMD-85/4
50 60 80 100 110 135
32A
Base for separate mountGT-85
Setting ranges (A)
GTK-40GTH-40/3GTH-40
GTK-40/L
GTK-85GTH-85/3GTH-85
GTK-85/L
7 - 109 - 13
12 -1816 - 2218 - 2624 - 36
28 - 4034 -5045 - 6554 - 7563 - 85
GT-40
Setting ranges (A)
4 - 65 - 86 - 97 - 109 - 13
12 -1816 - 2218 - 2624 - 3628 - 40
separate mount
40A 50A 65A 75A 85A
GMP40
2-poleSide mount
4-poleFront mount
2-poleFront mount
20
Contactors & Overload relays100 to 800A
Types AC/DC GMC-100 GMC-125 GMC-150 common coil
Ratings / IEC60947-4 kW A kW A kW A
AC1 160 160 210
AC3 200/240V 30 105 37 125 45 150
380/440V 55 105 60 120 75 150
500/550V 55 85 60 90 90 140
690V 55 65 60 70 90 100
Ratings / UL508 hp A hp A hp A
continuous current 160 160 210
single phase 115V 7.5 10 15
230V 15 20 25
three phase 200V 30 40 40
230V 30 40 50
460V 60 75 100
575V 60 75 100
NEMA size 3 3 4
Types AC/DC GMC-100/4 GMC-125/4 GMC-150/4common coil
AC1(A) 160 160 210
Additional auxiliary contacts
3-pole Contactors
100AFrame size 125A 150A
4-pole Contactors
Overload Relays
Bimetallic styleType GT
GT- 100
Setting ranges (A)
Differential
Class10A Non-differential (3-heater)
Non-differential (2-heater)
Class 20 Differential
GTK-100
GTH-100/3
GTH-100
GTK-100/L
GTK-150
GTH-150/3
GTH-150
GTK-150/L
34 - 50
39 - 57
43 - 65
54 - 80
65 - 100
85 - 125GT- 150
Setting ranges (A)
34 - 50
39 - 57
43 - 65
54 - 80
65 - 100
85 - 125
100 - 150
AU-1001NO+1NC, Side mount
21
GTK-220
GTH-220/3
GTH-220
GTK-220/L
GTK-400
GTH-400/3
GTH-400
GTK-400/L
GTK-600
GTH-600/3
GTH-600
GTK-600/L
GMC-180 GMC-220 GMC-300 GMC-400 GMC-600 GMC-800
kW A kW A kW A kW A kW A kW A
230 275 350 450 660 900
55 180 75 250 90 300 125 400 190 630 220 800
90 180 132 250 160 300 220 400 330 630 440 800
110 180 132 200 160 250 225 350 330 500 550 720
110 120 132 150 200 220 250 300 330 420 500 630
hp A hp A hp A hp A hp A hp A
230 275 350 450 660 900
15 15
30 40
60 60 100 125 150 250
60 75 100 150 200 300
125 150 200 300 400 600
125 150 200 300 400 600
4 4 5 5 6 7
GMC-180/4 GMC-220/4 GMC-300/4 GMC-400/4 GMC-600/4 GMC-800/4
230 275 350 450 660 900
180A 220A 300A 400A 600A 800A
GT- 220
Setting ranges (A)
65 - 100
85 - 125
100 - 150
120 - 180
160 - 240GT- 400
Setting ranges (A)
85 - 125
100 - 150
120 - 180
160 - 240
220 - 300
260 - 400
Setting ranges (A)
220 - 300
260 - 400
400 - 600
520 - 800
AU-1001NO+1NC, Side mount
GT- 800
Mini contactors6 to 16A
22
3NO main contacts
1 auxiliary contactsScrew clamp type Fast-on type Cage clamp type Solder pin type
Mini contactors
Overload Relays
Bimetallic styleType GT
Screw clamp type AC coil GMC-6M GMC-9M GMC-12M GMC-16M
DC coil GMD-6M GMD-9M GMD-12M GMD-16M
Fast-on type AC coil GMC-6MF GMC-9MF GMC-12MF GMC-16MF
DC coil GMD-6MF GMD-9MF GMD-12MF GMD-16MF
Cage clamp type AC coil GMC-6MC GMC-9MC GMC-12MC GMC-16MC
DC coil GMD-6MC GMD-9MC GMD-12MC GMD-16MC
Solder pin type AC coil GMC-6MP GMC-9MP GMC-12MP GMC-16MP
DC coil GMD-6MP GMD-9MP GMD-12MP GMD-16MP
Ratings / IEC60947-4 kW A kW A kW A kW A
AC1 20 20 20 20
AC3 200/240V 1.5 7 2.2 9 3 12 4 15
380/440V 2.2 6 4 9 5.5 12 7.5 16
500/550V 3 5 3.7 6 4 7 5.5 9
690V 3 4 4 5 4 5 4 5
Ratings / UL508 hp A hp A hp A hp A
continuous current Ith = 20A (maximum for cage clamp type is 10A)
single phase 120V 1/2 1/2 1 * -
230V/240V 1 1.5 2 * * -
three phase 240V 1.5 3 3 -
480V 3 5 7.5 * * * -
600V 3 5 7.5 -
Wire Range : Copper, 75°C, Stranded, 18-12AWG
NEMA size 00 00 00 0
Base for separate mountGT-12M
Setting ranges (A)
Differential
Non-differential (3-heater)
Non-differential (2-heater)
GTK-12M
GTH-12M/3
GTH-12M
0.1 - 0.160.16 - 0.250.25 - 0.40.4 - 0.63
0.63 - 11 - 1.6
1.6 - 2.52.5 - 4
4 - 65 - 86 - 97 - 109 - 13
12 - 16
Frame size 6A 9A 12A 16A
AU-2M
AU-1M
AU-4M
AU-2MF
AU-1MF
AU-4MF
AU-2MC
AU-1MC
AU-4MC AU-1MP
Additional auxiliary contacts
Note) * = 1/2 for cage clamp type, ** = 1.5hp for cage clamp type, *** = 5hp for cage clamp type16AF : not approved from UL
2-pole, Front mount
4-pole, Front mount
2-pole, Side mount
Fast-on type Cage clamp type Solder pin typeScrew clamp type
23
Digital motor protection relay
Model No. DMP06-S/Sa DMP60-S/Sa DMP06-T/Ta DMP06-T/Ta Wiring Screw type Tunnel type
Panel mount Unit or Extension Note1)
Operation time Select either reverse time characteristics or definite time characteristics
Protection Over current According to the setting time
Phase failure 3 sec.
Reverse phase Within 0.1 sec.
Asymmetry 5 sec.
Stall 5 sec.
Lock Within 0.5 sec.
Under current 3 sec.
Ground fault Within 0.05~1 sec. Selectable (0.05~1.0sec)
Short circuit Note2) Within 50ms
Alarm Variable (60~110% of the setting current)
Current setting range (A) 0.5~6 5~60 0.5~6 5~60
Motor capacity 220~240V 0.09~0.75 1.1~11 0.09~0.75 1.1~11
(kW) 380~440V 0.12~1.5 2.2~22 0.09~1.5 2.2~22
Time setting Definite Delay in starting 0~60sec
range (sec) time Delay in operating 0~30sec
Inverse time 0~60sec
Reset Manual reset
Tolerance Current ±5%
Time ±5% (or±0.5sec)
Operating power Voltage AC 190~250V
Note3) Frequency 60Hz (50Hz)
Aux. contact OL 2-SPST 3A/250Vac Resistive load
AL SPST 3A/250Vac Resistive load
Insulation resistance Over DC500V 100㏁
Surge impulse voltage(IEC1000-4-5) 1.2×50㎲ 6kV (Apply standard wave form)
Fast transient burst(IEC1000-4-4) 2.5kV/5min
Environment Temperature Operation -25~70℃
Storage -30~80℃
Humidity 30~90% RH (No freezing)
Display 7-Segment 3 phase current, cause of a fault
Bar-Graph 60~110% of real load current
Mounting type 35mm Din-rail/Panel
Note1) In extension type, the digital EMPR is calibrated with combining the display past and main body so, please cautious not to combine the display part and main body with different part No.
Note2) Instantaneous short circuit protection is optional Note3) Operational voltage of AC 110V and 50Hz is optional
DMP��-S/Sa DMP��-T/Ta
��For your safety, please read user's manual thoroughly before operating.
��Contact the nearest authorized service facility for examination, repair, or adjustment.
��Please contact qualified service technician when you need maintenance.Do not disassemble or repair by yourself!
��Any maintenance and inspection shall be performed by the personnel having expertise concerned.Safety Instructions
��LS Industrial Systems (Middle East) FZE ����Dubai, U.A.E. Address: P.O.Box-114216, API World Tower, 303B, Sheikhe Zayed Road, Dubai, U.A.E. Tel: 971-4-332-8289 Fax: 971-4-332-9444 e-mail: [email protected]
��Dalian LS Industrial Systems Co., Ltd. ����Dalian, ChinaAddress: No.15, Liaohexi 3-Road, Economic and Technical Development zone, Dalian 116600, ChinaTel: 86-411-8273-7777 Fax: 86-411-8730-7560 e-mail: [email protected]
��LS Industrial Systems (Wuxi) Co., Ltd. ����Wuxi, chinaAddress: 102-A , National High & New Tech Industrial Development Area, Wuxi, Jiangsu,214028, P.R.ChinaTel: 86-510-8534-6666 Fax: 86-510-522-4078 e-mail: [email protected]
��LS-VINA Industrial Systems Co., Ltd. ����Hanoi, VietnamAddress: Nguyen Khe - Dong Anh - Ha Noi - Viet NamTel: 84-4-882-0222 Fax: 84-4-882-0220 e-mail: [email protected]
��LS Industrial Systems Tokyo Office ����Tokyo, JapanAddress: 16FL, Higashi-Kan, Akasaka Twin Tower 17-22, 2-chome, Akasaka, Minato-ku Tokyo 107-8470, JapanTel: 81-3-3582-9128 Fax: 81-3-3582-2667 e-mail: [email protected]
��LS Industrial Systems Shanghai Office ����Shanghai, ChinaAddress: Room E-G, 12th Floor Huamin Empire Plaza, No.726, West Yan'an Road Shanghai 200050, P.R. ChinaTel: 86-21-5237-9977 (609) Fax: 89-21-5237-7191 e-mail: [email protected]
��LS Industrial Systems Beijing Office ����Beijing, ChinaAddress: B-Tower 17FL.Beijing Global Trade Center B/D. No.36, BeiSanHuanDong-Lu, DongCheng-District,Beijing 100013, P.R. ChinaTel: 86-10-5825-6025,7 Fax: 86-10-5825-6026 e-mail: [email protected]
��LS Industrial Systems Guangzhou Office ����Guangzhou, ChinaAddress: Room 1403,14F,New Poly Tower,2 Zhongshan Liu Road,Guangzhou, P.R. ChinaTel: 86-20-8326-6764 Fax: 86-20-8326-6287 e-mail: [email protected]
��LS Industrial Systems Chengdu Office ����Chengdu, ChinaAddress: 12Floor, Guodong Buiding, No52 Jindun Road Chengdu, 610041, P.R. ChinaTel: 86-28-8612-9151 Fax: 86-28-8612-9236 e-mail: [email protected]
��LS Industrial Systems Qingdao Office ����Qingdao, ChinaAddress: 7B40,Haixin Guangchang Shenye Building B, No.9, Shandong Road Qingdao 26600, P.R. ChinaTel: 86-532-8501-6568 Fax: 86-532-583-3793 e-mail: [email protected] in this catalog are subject to change without notice due to
continuous product development and improvement.
�� HEAD OFFICEYonsei Jaedan Severance Bldg., 84-11, Namdaemunno 5ga,Jung-gu, Seoul, 100-753, KoreaTel. (82-2)2034-4870Fax. (82-2)2034-4713
�� CHEONG-JU PLANTCheong-Ju Plant #1, Song Jung Dong, Hung Duk Ku,Cheong Ju, 361-720, Korea
Leader in Electrics & Automation
��Global Network
www.lsis.biz
2008. 03 LOW VOLTAGE CIRCUIT BREAKERS & CONTACTORS(E) 2004. 02/(20) 2008. 03 Printed in Korea STAFF
ⓒ 2004.2 LS Industrial Systems Co.,Ltd. All rights reserved.