THESE INSTRUCTIONS TO BE RETAINED BY USER Vokèra is a licensed member of the Benchmark scheme which aims to improve the standards of installation and commissioning of domestic hot water systems in the UK. Linea HE High efficiency combi boiler Users Instructions

Transcript of Linea HE front - Vokeracdn0.vokera.co.uk/wp-content/uploads/2009/04/linea-he-user-manual.pdf · 2...

Page 1: Linea HE front - Vokeracdn0.vokera.co.uk/wp-content/uploads/2009/04/linea-he-user-manual.pdf · 2 Linea HE Dear Customer Your Linea HE boiler has been designed to meet and exceed

THESE INSTRUCTIONSTO BE RETAINEDBY USER

Vokèra is a licensed member of the Benchmark schemewhich aims to improve the standards of installation and commissioning of domestic hot water systems in the UK.

Linea HEHigh efficiency combi boiler

UsersInstructions

Page 2: Linea HE front - Vokeracdn0.vokera.co.uk/wp-content/uploads/2009/04/linea-he-user-manual.pdf · 2 Linea HE Dear Customer Your Linea HE boiler has been designed to meet and exceed

2 Linea HE

Dear CustomerYour Linea HE boiler has been designed to meet and exceed the very latest standards in gas central heating technol-ogy, and if cared for, will give years of reliable use and efficiency.Please therefore take some time to read these instructions carefully.

Do’s and Don’t’s● Do ensure that the system pressure is periodically checked● Do ensure that you know how to isolate the appliance in an emergency● Do ensure that you are familiar with the appliance controls● Do ensure that your installer has completed the appliance log book● Do not attempt to remove the appliance casing or gain internal access● Do not hang clothes etc. over the appliance● Do not forget to have the appliance serviced annually.

Contents

Introduction PageDear customer 2Do’s and don’t’s 2

Things you should know Page1.1 Gas appliances 41.2 Electrical supply 41.3 Guarantee registration card 41.4 Benchmark log book 41.5 How does it work? 41.6 Dimensions 41.7 Clearances required 41.8 Frost protection system 41.9 Additional controls 4

Getting started Page2.1 Before switching on 52.2 Appliance controls 52.3 Lighting the boiler 52.4 Adjusting the operating temperatures 62.5 Digital display 62.6 Fault code table 62.7 Information mode 7

How to... Page3.1 Top-up the system pressure 83.2 Reset the appliance 83.3 Shut down the system for short periods 83.4 Shut down the system for long periods 83.5 Care for the appliance 83.6 Regulate the hot water temperature 8

What if... Page4.1 I suspect a gas leak 94.2 I have to frequently to top-up the system 94.3 The reset light is on 94.4 The appliance is due its annual service 94.5 I need to call an engineer 9

INTRODUCTION

Page 3: Linea HE front - Vokeracdn0.vokera.co.uk/wp-content/uploads/2009/04/linea-he-user-manual.pdf · 2 Linea HE Dear Customer Your Linea HE boiler has been designed to meet and exceed

3Linea HE

Fig. 1

1= central heating temperature control

2= ON/OFF/RESET button

3= MODE button

4= INFO button

5= hot water temperature control

current water pressure

outside sensor

current appliance temperature

error code

current mode of operation

burner on

frost protection on

insufficient water pressure

Symbols description

Summer

Spring

Autumn

Winter

central heating temperature bar

hot water temperature bar

service request reset

1 53 42

Page 4: Linea HE front - Vokeracdn0.vokera.co.uk/wp-content/uploads/2009/04/linea-he-user-manual.pdf · 2 Linea HE Dear Customer Your Linea HE boiler has been designed to meet and exceed

4 Linea HE

THINGS YOU SHOULD KNOW

1.1 GAS APPLIANCEGas Safety (Installations and Use) Regulations.In the interests of your safety and that of others itis a legal requirement that all gas appliances areinstalled and correctly maintained by a competentperson and in accordance with the latest regula-tions.

1.2 ELECTRICAL SUPPLYPlease ensure that this appliance has been prop-erly connected to the electrical supply by meansof a double pole isolator or un-switched socket,and that the correct size of fuse (3 AMP) has beenfitted.Warning: this appliance must be earthed!

1.3 GUARANTEE REGISTRATION CARDPlease take the time to fill out your guaranteeregistration card. The completed warranty cardshould be posted within 30 days of installation.

1.4 BENCHMARK LOG BOOKThe Benchmark Log Book is supplied with yourboiler. This important document must be com-pleted during the installation/commissioning ofyour boiler. All CORGI Registered Installers carrya CORGI ID card and have a registration number.Both should be recorded in your Benchmark LogBook. You can check your installer by callingCORGI direct on 01256 372300. Failure to installand commision the appliance in accordance withthe manufacturers instructions may invalidate thewarranty. This does not affect your statutoryrights.

1.5 HOW DOES IT WORK?Your Linea HE boiler is a high efficiency combina-tion boiler, which supplies heated water to yourradiators and hot water to your taps.The central heating is controlled via a time clockand/or any thermostats that your installer mayhave fitted. The boiler will light when a hot wateroutlet (a tap) is opened. The boiler may alsofunction periodically to pre-heat the hot water heatexchanger. The Linea HE boiler lights electroni-cally and does not have a pilot light. In the unlikelyevent of a fault developing with your boiler, thesupply of gas to the burner will be terminatedautomatically.

1.6 DIMENSIONS

HEIGHTWIDTHDEPTH

845 mm453 mm390 mm

1.7 CLEARANCES REQUIRED

ABOVEBELOWSIDESFRONT

150 mm120 mm12 mm600 mm

1.8 FROST PROTECTION SYSTEMThe Linea HE is equipped with a built-in frostprotection system, this enables the boiler to over-ride the time controls – if switched off – andoperate the burner and/or pump, should the tem-perature drop below 6 °C.Please note that the frost protection system isdesigned to protect the appliance only, shouldfrost protection be required for the central heatingsystem, additional controls may be required.NOTEThe frost protection system is reliant on the ap-pliance having a permanent electrical supply, andbeing in a non-fault condition.

1.9 ADDITIONAL CONTROLSAdditional controls such as an external tempera-ture sensor kit or under floor heating safety ther-mostat are available as optional accessories forthis appliance. You should consult your installerand/or the supplementary instructions supplied,on their use (if installed).

Page 5: Linea HE front - Vokeracdn0.vokera.co.uk/wp-content/uploads/2009/04/linea-he-user-manual.pdf · 2 Linea HE Dear Customer Your Linea HE boiler has been designed to meet and exceed

5Linea HE

GETTING STARTED

2.1 BEFORE SWITCHING ONBefore switching the appliance on pleasefamiliarise yourself with:● how to isolate the appliance from the gas, water

and electricity supplies;● how to check and top-up – if necessary – the

system water pressure;● any external thermostats/time switches and

their functions;● the appliance controls.

2.2 APPLIANCE CONTROLS (see fig. 1)The appliance controls are concealed behindthe front cover. To gain access to the controlssimply push-in the release button to open thecover. The appliance is equipped with a simplecontrol panel that can be used to alter or controlthe following functions:● ON/OFF selection;● mode of operation;● the outlet flow temperature to the central heating

system;● the outlet temperature for domestic hot water.In addition, the large LCD display shows the statusof the appliance:● current mode of operation;● current appliance temperature;● current temperatures selected;● current system water pressure.The system water pressure display shows thecurrent pressure of the system, andWhen theappliance is operating the display may rise or fall,this is quite normal. The minimum permissiblelevel for the safe and efficient operation of theappliance is 0.6 BAR. Should the pressure fallbelow 0.6 BAR, the boiler may lockout.Depending on the type of controls specified byyour installer you may have an external time clockor programmer fitted, please refer to the instruc-tions supplied with such.

2.3 LIGHTING THE BOILEREnsure the gas and electrical supply to the boilerare turned on.Using figure 1 as a guide, locate and press the ON/OFF selection button if the appliance isn’t alreadyswitched on. The boiler will now go through a self-test sequence. On completion of the self-testsequence, the boiler will be ready to provideheating and/or hot water if required.

2.3.1 MODES OF OPERATIONWhen the appliance is switched on one of fourmodes of operation can be selected:● summer;● spring;● autumn;● winter.

SummerWhen the summer mode is selected, the appli-ance will respond to requests for Domestic HotWater (DHW). In the summer mode the TSC(Temperature Stability Control) function is active.All heating requests will be ignored.

SpringWhen the spring mode is selected, the appliancewill respond to requests for Domestic Hot Water(DHW). All heating requests will be ignored.AutumnWhen the autumn mode is selected, the appliancewill respond to requests for DHW and/or heating.During the autumn mode, the SARA function(Automatic Temperature Control), and the TSC(Temperature Stability Control) are active.WinterWhen the winter mode is selected, the appliancewill respond to requests for DHW and/or heating.During the winter mode, the booster function andpre-heat function are active.

2.3.2 FUNCTIONS●●●●● TSC: when the TSC function is active (sum-

mer/autumn) the appliance may over-ride theselected DHW temperature in order to maintaintemperature stability.

● SARA: when the SARA function is active (au-tumn) and the selected heating temperature isset between 55o – 65oC, the appliance willautomatically raise the heating outlet tempera-ture when the selected set temperature cannotbe achieved or maintained.

● BOOSTER: when the booster function is active(winter), the appliance will automatically raisethe heating outlet temperature when the se-lected set temperature cannot be achieved ormaintained.

● PRE-HEAT: when the pre-heat function is active(winter), the appliance will periodically heat theDHW heat exchanger to reduce waiting timeduring DHW requests.

● FROST PROTECTION: the frost protectionfunction is active at all times even when theappliance ON/OFF selector is at OFF. Shouldthe temperature fall to 6 oC, the boiler will oper-ate to reduce the risk of frost damage.

●●●●● ANTI-BLOCK: the anti-block function is activeat all times even when the appliance ON/OFFselector is at OFF. Should the appliance beinactive for 19-hours, both the pump and divertorvalve actuator will be energised for a short periodto reduce the risk of component seizure.

NOTEThe frost protection and anti-block functions arereliant on the appliance having a permanentelectrical supply, and being in a non-fault condition.

2.3.3 HEATING REQUESTWhen there is a demand for heating via the timeclock etc, the boiler will go through an ignitionsequence, whereby the burner will light.When the appliance reaches the set temperature,the burner will go off for minimum period of approxi-mately 5 minutes.When the programmer/time clock or external ther-mostats heating request has been satisfied, theappliance will switch off automatically.

Page 6: Linea HE front - Vokeracdn0.vokera.co.uk/wp-content/uploads/2009/04/linea-he-user-manual.pdf · 2 Linea HE Dear Customer Your Linea HE boiler has been designed to meet and exceed

6 Linea HE

2.6 FAULT CODE TABLE

ReasonIgnition anomaly

No flame detectedRestarts ignition

Wiring faultHeat exchanger temperature

too highWiring faultWiring fault

Fan faultFan fault

Low water pressureLow water pressurePressure gauge fault

Internal faultInternal faultSensor faultWiring fault

Temperature anomalyTemperature anomaly

Wiring faultTemperature anomaly

Internal faultCondense pipe blockedCondense pipe blocked

Wiring fault

Code101112

13/1420/21/22

23/3130

32/3433/35

404142

50/51/5253/54/55/56

60/6162

70/72/7471/7375/76

7780/90/91

9293/95

94

Action requiredReset appliance, if fault continues, call engineer

WaitWait

Call engineerCall engineer

WaitCall engineerCall engineer

WaitCheck/restore system pressure and reset

Check/restore system pressureCall engineer

Reset appliance, if fault continues, call engineerReset appliance, if fault continues, call engineer

Call engineerCall engineerCall engineer

WaitCall engineerCall engineerCall engineerCall engineer

WaitCall engineer

2.3.4 HOT WATER REQUESTWhen a hot water outlet or tap is opened, theboiler senses water flow and initiates an ignitionsequence. The boiler will modulate the output ac-cording to the temperature required, when the hotwater request has been satisfied, the boiler maycontinue to operate if the pre-heat function isactive.NOTEIf the appliance fails to ignite during the ignitionsequence, it will re-attempt ignition several timesbefore going to a lockout condition. Should thisoccur, please allow a period of two minutes beforere-setting.

2.4 ADJUSTING THE OPERATING TEMPERA-TURES (see fig.1)The temperature selector knobs can be rotated toincrease or decrease the currently selected tem-peratures. The display will show any increase ordecrease relative to the corresponding selectorknob.

2.4.1 ADJUSTING THE CENTRAL HEATING TEM-PERATURES (see fig.1)If an outside temperature sensor is not connectedto the boiler the heating selector can be adjustedbetween 20 °C and 80 °C.

If an outside temperature sensor is connected to

the boiler ( on) the central heating temperatureis automatically calculated from the boiler in orderto have a room temperature of 20 °C. It is possibleto adjust this value with the heating selector knobfrom - 5 °C up to + 5 °C.

2.4.2 ADJUSTING THE HOT WATER TEMPERA-TURES (see fig.1)The hot water selector can be adjusted between35° and 60 °C.

2.5 DIGITAL DISPLAYThe digital display shows the current mode ofoperation and/or status of the boiler.Should a fault develop, the display will show aunique fault code that can be used to help rectifythe cause of the fault.Should a fault code be displayed, check thefault code table to identify the cause and courseof action to take.Always wait 2-minutes before pressing thereset button.

Page 7: Linea HE front - Vokeracdn0.vokera.co.uk/wp-content/uploads/2009/04/linea-he-user-manual.pdf · 2 Linea HE Dear Customer Your Linea HE boiler has been designed to meet and exceed

7Linea HE

2.7 INFORMATION MODEThe appliance keypad can be used to displaycertain information on the working status of theboiler. Push the Info button ( ) to enter the infomenu (fig. 2). The following information are shownpushing subsequently the button:

Info 1 outside temperature (only if outside sensorconnected) (fig. 3)

Info 2 water pressure (fig. 4)Info 3 CH temperature set (fig. 5)Info 4 DHW temperature set (fig. 4.6).

Fig. 3

Fig.4

Fig. 5

Fig. 2

Fig. 6

Page 8: Linea HE front - Vokeracdn0.vokera.co.uk/wp-content/uploads/2009/04/linea-he-user-manual.pdf · 2 Linea HE Dear Customer Your Linea HE boiler has been designed to meet and exceed

8 Linea HE

HOW TO...

3.1 HOW TO TOP-UP THE SYSTEM PRESSURE(fig. 4)The system pressure must be checked periodi-cally to ensure the correct operation of the boiler.The display should ideally be reading between0.6 (minimum) and 1.5 (maximum) when theboiler is in an off position and has cooled to roomtemperature. If the pressure requires ‘topping-up’use the following instructions as a guide.● Locate the filling valve connections (beneath

the boiler).● Attach the filling loop to both connections.● Open the filling valve slowly until you hear water

entering the system.● Close the filling valve when the displayed pres-

sure (on the boiler) reads between 1 and 1.5.● Remove the filling loop from the connections.

3.2 HOW TO RESET THE APPLIANCEWhen the display is flashing, or when the reseticon is shown, the appliance will require to bereset manually. Before resetting the boiler ensurethat the displayed pressure is indicating the cor-rect level. Allow a period of two minutes to elapsebefore pressing the reset button.

IMPORTANTIf the appliance requires to be reset frequently, itmay be indicative of a fault, please contact yourinstaller or Vokera Customer Services for furtheradvice.

3.3 HOW TO SHUT DOWN THE SYSTEM FORSHORT PERIODSThe system and boiler can be shut down for shortperiods by simply turning the time clock to the offposition. It is also advisable to turn off the mainwater supply to the house.

3.4 HOW TO SHUT DOWN THE SYSTEM FORLONG PERIODSIf the house is to be left unoccupied for any lengthof time – especially during the winter – the systemshould be thoroughly drained of all water.The gas, water, and electricity supply to the houseshould also be turned off. For more detailedadvice contact your installer.

3.5 HOW TO CARE FOR THE APPLIANCETo clean the outer casing use only a clean dampcloth. Do not use any scourers or abrasive clean-ers.

3.6 HOW TO REGULATE THE HOT WATER TEM-PERATUREUsually your installer will have adjusted the hotwater output to suit your requirements, howeverif you would like to adjust the outlet temperature,please follow the instructions in section 2.4.

NOTEIf you find that the hot water temperature is stillinsufficient, try reducing the flow of water throughthe tap.

normal op-e r a t i n gposition

filling posi-tion

closedposition

Fig. 5

Fig. 4

Hot water outlet

Cold water inletstopcock/filling

valve

Gascock

Filling loop

C/H flowvalve

C/H returnvalve

Safetyvalve outlet

Page 9: Linea HE front - Vokeracdn0.vokera.co.uk/wp-content/uploads/2009/04/linea-he-user-manual.pdf · 2 Linea HE Dear Customer Your Linea HE boiler has been designed to meet and exceed

9Linea HE

4.5 WHAT IF I NEED TO CALL AN ENGINEERIf you think your boiler may have developed a faultplease contact your installer or Vokera CustomerServices (0870 333 0220 (UK) or 05655057(ROI) have all your details to hand including fulladdress and postcode, relevant contact num-bers, and your completed appliance log book.

WHAT IF...

4.1 WHAT IF I SUSPECT A GAS LEAKIf you suspect a gas leak, turn off the gas supplyat the gas meter, and contact your installer or localgas supplier. I you require further advice pleasecontact your nearest Vokera office.

4.2 WHAT IF I HAVE FREQUENTLY TO TOP-UPTHE SYSTEMIf the system regularly requires topping-up, it maybe indicative of a leak. Please contact your in-staller and ask him to inspect the system.

4.3 WHAT IF THE RESET LIGHT IS ONIf the reset icon is shown, it indicates that theboiler has failed to ignite or has overheated, whenthis happens the boiler automatically shuts downand requires to be reset manually (see 3.2).

4.4 WHAT IF THE APPLIANCE IS DUE ITS AN-NUAL SERVICEAdvice for tenants onlyYour landlord should arrange for servicing.Advice for homeownersPlease contact Vokera Customer Service (0870333 0220 (UK) or 05655057 (ROI) if you wouldprefer a Vokera service engineer or agent toservice your appliance. Alternatively your localCORGI registered engineer may be able to serv-ice the appliance for you.

Page 10: Linea HE front - Vokeracdn0.vokera.co.uk/wp-content/uploads/2009/04/linea-he-user-manual.pdf · 2 Linea HE Dear Customer Your Linea HE boiler has been designed to meet and exceed

10 Linea HE

NOTE

Page 11: Linea HE front - Vokeracdn0.vokera.co.uk/wp-content/uploads/2009/04/linea-he-user-manual.pdf · 2 Linea HE Dear Customer Your Linea HE boiler has been designed to meet and exceed

11Linea HE

Page 12: Linea HE front - Vokeracdn0.vokera.co.uk/wp-content/uploads/2009/04/linea-he-user-manual.pdf · 2 Linea HE Dear Customer Your Linea HE boiler has been designed to meet and exceed

Registered address:Vokèra Ltd

Borderlake HouseUnit 7 Riverside Industrial Estate

London ColneyHerts AL2 1HG

[email protected]

www.vokera.co.ukwww.vokera.ie

Sales, General EnquiresT 0844 391 099

F 0844 391 0998

Vokèra IrelandWest Court, Callan

Co KilkennyT 056 7755057F 056 7755060

Vokèra Limited reserve the right to changespecification without prior notice

Consumers statutory rights are not affected.

A Riello Group Company.Company Reg No: 1047779

Cod

. 100

2649

2 - 1

0/05

- Ed

. 2