Life made simple Meet the changingc398534.r34.cf1.rackcdn.com/DOCUMENTS/1071960... · *Clinical...

6
Meet the changing needs of your patients Trilogy Series, with advanced ventilator technology

Transcript of Life made simple Meet the changingc398534.r34.cf1.rackcdn.com/DOCUMENTS/1071960... · *Clinical...

Page 1: Life made simple Meet the changingc398534.r34.cf1.rackcdn.com/DOCUMENTS/1071960... · *Clinical guidelines recommend that COPD patients should use oxygen therapy for at least 15 hours

Philips Healthcare is part of Royal Philips Electronics

How to reach uswww.philips.com/[email protected]: +31 40 27 64 887

Asia+852 2821 5888

Europe, Middle East, Africa+49 7031 463 2254

Latin America+55 11 2125 0744

North America+1 425 487 7000800 285 5585 (toll free, US only)

© 2012 Koninklijke Philips Electronics N.V. All rights are reserved.

Philips Healthcare reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. Broudy NA 09/14/12 MCI 4104848 PN 1071960

Philips Respironics1010 Murry Ridge LaneMurrysville, PA 15668

Customer Service+1 724 387 4000800 345 6443 (toll free, US only)

Respironics Asia Pacific+65 6882 5282

Respironics Australia+61 (2) 9666 4444

Respironics Deutschland+49 8152 93 06 0

Respironics Europe, Middle East, Africa+33 1 47 52 30 00

Respironics France+33 2 51 89 36 00

Respironics Italy+39 039 203 1

Respironics Sweden+46 8 120 45 900

Respironics Switzerland+41 6 27 45 17 50

Respironics United Kingdom+44 800 1300 845

www.philips.com/respironics

Product specifications

Ventilation modes

• Pressure modes (CPAP, S, ST, PC, T, PC-SIMV)

• Volume modes (AC, CV, SIMV)• AVAPS hybrid ventilation (only with passive exhalation port circuit)• Dual prescription• Invasive and non-invasive capabilities• For adults and children (> 5 kg)

Circuit configurations

• Passive exhalation port circuit• Active exhalation valve circuit with proximal

pressure line• Active exhalation valve circuit with proximal

flow sensor (available on the Trilogy200 only)

Triggers • Auto-TRAK sensitivity (only with passive exhalation port circuit)

• Adjustable flow triggers

IPAP • 4 to 50 cmH2O

EPAP • 0 to 25 cmH2O with active exhalation valve• 4 to 25 cmH2O with passive exhalation port

PEEP • 0 to 25 cmH2O with active exhalation valve• 4 to 25 cmH2O with passive exhalation port

Pressure support

• 0 to 30 cmH2O

Tidal volume • 50 to 2000 ml

Breath rate • Up to 60 BPM

Inspiratory time

• 0.3 to 3 seconds

Rise time • 1 (100 ms) to 6 (600 ms)

O2 inlet • Back of the device (low pressure) up to 15 L/min

Size • 16 (L) x 28 (W) x 23 (H)

Weight • 5 kg (with detachable battery)

Customizable user-interface

• Full detailed configuration for hospital use• Limited detailed configuration for home use

Bags • Carrying bag• In-use bag

Settable alarms • Patient disconnection• Apnoea• Low/high tidal volume• Low/high minute ventilation• Low/high respiratory rate• Low/high inspiratory pressure

(in volume modes)• Low SpO2*

Monitoring • Exhaled tidal volume• Exhaled minute ventilation• Leak rate• Respiratory rate• Peak inspiratory flow• Peak inspiratory pressure• I:E ratio• Mean airway pressure• SpO2*

Battery • Internal battery: 3 to 4 hours• Detachable battery: 3 to 4 hours• External battery connection : 12 VDC

Data management

• DirectView software• 1 GB SD card data storage

Polygraph & Polysomnographconnections

• Direct connection to Alice PDx and Alice 5 PSG

• AOM to connect to most PSG systems

Simple ventilation, sophisticated technology

Circuit typePassive Active with PAP Active with Flow

Ventilation type Volume and pressure modes for non-invasive and invasive modalitiesMinimum PEP of 4 required Allows 0 PEP Allows 0 PEP

Leak compensation Exceptional Good Very goodTriggering Auto-TRAK & Flow Flow Advanced flow triggeringExhaled gas monitoring Estimation — Measurement

Trilogy100 ✓ ✓ —

Trilogy200 ✓ ✓ ✓

* When SpO2 module connected using the Trilogy SPO2 cable: PN 1080964

Trilogy100, Trilogy200, DirectView, Auto-TRAK, AVAPS, Alice 5 and Alice PDx are trademarks of Respironics, Inc. and its affiliates. Microsoft and Excel are registered trademarks of Microsoft Corporation.

Meet the changing needs of your patients Trilogy Series, with advanced ventilator technology

Life made simple

©2012 Koninklijke Philips Electronics N.V. All rights reserved.Philips Healthcare reserves the right to make changes in specifications and/or to discontinue any product at any time without noticeor obligation and will not be liable for any consequences resulting from the use of this publication.

CAUTION: US federal law restricts these devices to sale by or on the order of a physician.

Respironics, FitLife, and EZ Peel are trademarks of Respironics, Inc. and its affiliates.

Broudy AE 5/21/12 MCI 4104723 PN 1098670

Notes*Clinical guidelines recommend that COPD patients should use oxygen therapy for at least 15 hours perday to have positive effects on their long term survival and their quality of life. Therefore these patientsrequire oxygen at home (stationary oxygen therapy) and outside (ambulatory oxygen therapy).

SimplyGo - reliability andmaintenance made simple!

Built-in reliabilitySimplyGo strives to set a new standard in portable concentrators’ reliability. SimplyGo has been designed, built, and rigorously tested towithstand the stress of everyday life when following patientsanytime, anywhere.

During development, SimplyGo was subjected to extreme conditionsincluding impact, vibrations, and temperature extremes to test reliableperformance day-in and day-out.With 15000 hours of compressor lifetime, its performance is trustworthy. This may mean fewer callbacks for you and fewer frustrations for your patients due to accidental damage.

You can count on SimplyGo.

COPD (chronic obstructive pulmonary disease) patients are dependent on oxygen therapyequipment that they need for many hours* a day. SimplyGo offers the independence and freedompatients want in a durable design that can resist the bumps and bruises of daily activities whileproviding an effective therapy.

Please visit www.philips.com/respironics

Philips Healthcare is part of Royal Philips Electronics

How to reach uswww.philips.com/[email protected]

Asia+49 7031 463 2254

Europe, Middle East, Africa+49 7031 463 2254

Latin America+55 11 2125 0744

North America+1 425 487 7000 800 285 5585 (toll free, US only)

Philips Respironics Deutschland+49 8152 93 06 0

Philips Respironics France+33 2 51 89 36 00

Philips Respironics Italy+39 039 203 1

Philips Respironics Sweden+46 8 120 45 900

Philips Respironics Switzerland +41 6 27 45 17 50

Philips Respironics United Kingdom+44 800 1300 845

www.philips.com/respironics

Philips Respironics1010 Murry Ridge LaneMurrysville, PA 15668

Customer Sevice+1 724 387 4000800 345 6443 (toll free, US only)

Philips Respironics InternationalHeadquarters+33 1 47 28 30 82

Philips Respironics Asia Pacific +65 6882 5282

Philips Respironics Australia+61 (2) 9947 04401300 766 488 (toll free,Australia only)

Philips Respironics China+86 400 828 6665+86 800 828 6665

Contact us

Maintenance made simple!SimplyGo makes it easy for providers, as it requires virtuallyno preventive or patient maintenance.

SimplyGo is flexible:• Make a choice between two-, three-, or five-year warranty.

Pick the plan that’s best for your service.

• SimplyGo’s easily accessible parts and comprehensive service tools allow your technicians to service the device in-house instead of returning it to the manufacturer.

Philips Respironics SimplyGo portable oxygen concentrator - simplychanges your patient’s life

Respironics, SimplyGo, and EverFlow are trademarks of Respironics, Inc. and its affiliates.All rights reserved.

© 2012 Koninklijke Philips Electronics N.V. All rights are reserved.

Philips Healthcare reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication.

Broudy AE 9/12/12 MCI 4105036 PN 1102086

Please visit www.philips.com/respironics

Philips Healthcare is part of Royal Philips Electronics

Philips Respironics International Headquarters+33 1 47 28 30 82 Philips Respironics Asia Pacific+65 6882 5282Philips Home Healthcare Solutions Australia+61 (2) 9947 0440Philips Respironics United Kingdom+44 800 1300 845

Respironics New Jersey. Inc.5 Wood Hollow RoadParsippany, NJ 07054 USA

Customer Service+1 724 387 4000800 345 6443 (toll free, US only)www.philips.com/respironics

AVAPS-AE mode

Product specificationsVentilation modes •CPAP•S•S/T•PC•T•AVAPS-AEHybrid ventilation •AVAPS (Average Volume Assured Pressure Support)

•AVAPS-AEIPAP 4 – 40 cmH2OEPAP 4 – 25 cmH2OTarget tidal volume (AVAPS & AVAPS-AE)

200 – 1500 ml

Breath rate 0 – 40 bpm (4 – 40 bpm in T mode)Inspiratory time 0.5 – 3 sec.Triggering and cycling •Auto-Trak

•Sensitive Auto-Trak•Flow triggering

Rise time 1 (100 ms) – 6 (600 ms)Size 21.6 cm W x 19 cm L x 11.5 cm HWeight 2.1 kgs (with power supply)Noise level < 30 dBA at 10 cmH2OHumidification System One humidity control and ‘Dry Box’ technologyAlarms •Patientdisconnection

•Apnea •Lowminuteventilation •Lowtidalvolume(withAVAPS/AVAPS-AEonly) •Highrespiratoryrate

Monitoring •Pressure•Tidalvolume•Minuteventilation •Respiratoryrate•Leak•I/Eratio

Battery back up Detachable battery module: 5 hours at IPAP 12 cmH2O / EPAP 7 cmH2O and 12 bpm

DC power source •12VDC,5.0A(externalbattery) •24VDC,4.2A(powersupply)

Data management •EncorePro 2 and DirectView software•Compatible with oximetry module•Advanced detection of residual respiratory events

(apnea/hypopnea index, obstructed airway apnea, clear airway apnea, hypopnea, periodic breathing, RERA, large leak and snore)

Remote control Compatible with PC DirectPolygraph and polysomnograph connections

•Direct connection to Alice PDx and Alice6 PSGs•AOM to connect to most PSG systems

BiPAP A40, Auto-Trak, AVAPS, AVAPS-AE, EncorePro, DirectView, and Alice are trademarks of Koninklijke Philips Electronics N.V. All rights are reserved.

Ordering information Part no.DevicesBiPAP A40, International * 1076493BiPAP A40, Australia * 1076583* contains BiPAP A40 ventilator with SD card, power cord,

AC power adapter, user manual, ultra fine filter, grey foam filter, tubing, and carrying case

AccessoriesA Series humidifier, International 1077107 Battery module 1096770Detachable battery 1043570Ultra fine filter kit 1063096 Foam filter kit 1063091Power supply 1081167Power cord, Europe 1039014Power cord, UK 1039026Performance tubing 22 mm 1032907Performance tubing 15 mm 1074400EncorePro 2 software 1054785DirectView software 1005297RJ9 to 1/4” nurse call cable, closed 1080247RJ9 to 1/4” nurse call cable, open 1080248RJ9 nurse call cable, open ends 1080249Carrying bag 1098514BiPAP A40 in-use bag 1098513Oximetry accessory, INTL 100215EBiPAP A Series roll stand 1098538

In AVAPS-AE mode, the device monitors the patient’s upper airway resistance and automatically adjusts the delivered EPAP required to maintain an airway. Simultaneously, BiPAP A40 automatically adjusts pressure support to maintain a target tidal volume and when the breath rate is set to Auto, the device will adjust the back-up breath rate based on the patient’s spontaneous respiratory rate.

© 2012 Koninklijke Philips Electronics N.V. All rights are reserved.

Philips Healthcare reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication.

Broudy AE 9/12/12 MCI 4105036 PN 1102086

Please visit www.philips.com/respironics

Philips Healthcare is part of Royal Philips Electronics

Philips Respironics International Headquarters+33 1 47 28 30 82 Philips Respironics Asia Pacific+65 6882 5282Philips Home Healthcare Solutions Australia+61 (2) 9947 0440Philips Respironics United Kingdom+44 800 1300 845

Respironics New Jersey. Inc.5 Wood Hollow RoadParsippany, NJ 07054 USA

Customer Service+1 724 387 4000800 345 6443 (toll free, US only)www.philips.com/respironics

AVAPS-AE mode

Product specificationsVentilation modes •CPAP•S•S/T•PC•T•AVAPS-AEHybrid ventilation •AVAPS (Average Volume Assured Pressure Support)

•AVAPS-AEIPAP 4 – 40 cmH2OEPAP 4 – 25 cmH2OTarget tidal volume (AVAPS & AVAPS-AE)

200 – 1500 ml

Breath rate 0 – 40 bpm (4 – 40 bpm in T mode)Inspiratory time 0.5 – 3 sec.Triggering and cycling •Auto-Trak

•Sensitive Auto-Trak•Flow triggering

Rise time 1 (100 ms) – 6 (600 ms)Size 21.6 cm W x 19 cm L x 11.5 cm HWeight 2.1 kgs (with power supply)Noise level < 30 dBA at 10 cmH2OHumidification System One humidity control and ‘Dry Box’ technologyAlarms •Patientdisconnection

•Apnea •Lowminuteventilation •Lowtidalvolume(withAVAPS/AVAPS-AEonly) •Highrespiratoryrate

Monitoring •Pressure•Tidalvolume•Minuteventilation •Respiratoryrate•Leak•I/Eratio

Battery back up Detachable battery module: 5 hours at IPAP 12 cmH2O / EPAP 7 cmH2O and 12 bpm

DC power source •12VDC,5.0A(externalbattery) •24VDC,4.2A(powersupply)

Data management •EncorePro 2 and DirectView software•Compatible with oximetry module•Advanced detection of residual respiratory events

(apnea/hypopnea index, obstructed airway apnea, clear airway apnea, hypopnea, periodic breathing, RERA, large leak and snore)

Remote control Compatible with PC DirectPolygraph and polysomnograph connections

•Direct connection to Alice PDx and Alice6 PSGs•AOM to connect to most PSG systems

BiPAP A40, Auto-Trak, AVAPS, AVAPS-AE, EncorePro, DirectView, and Alice are trademarks of Koninklijke Philips Electronics N.V. All rights are reserved.

Ordering information Part no.DevicesBiPAP A40, International * 1076493BiPAP A40, Australia * 1076583* contains BiPAP A40 ventilator with SD card, power cord,

AC power adapter, user manual, ultra fine filter, grey foam filter, tubing, and carrying case

AccessoriesA Series humidifier, International 1077107 Battery module 1096770Detachable battery 1043570Ultra fine filter kit 1063096 Foam filter kit 1063091Power supply 1081167Power cord, Europe 1039014Power cord, UK 1039026Performance tubing 22 mm 1032907Performance tubing 15 mm 1074400EncorePro 2 software 1054785DirectView software 1005297RJ9 to 1/4” nurse call cable, closed 1080247RJ9 to 1/4” nurse call cable, open 1080248RJ9 nurse call cable, open ends 1080249Carrying bag 1098514BiPAP A40 in-use bag 1098513Oximetry accessory, INTL 100215EBiPAP A Series roll stand 1098538

In AVAPS-AE mode, the device monitors the patient’s upper airway resistance and automatically adjusts the delivered EPAP required to maintain an airway. Simultaneously, BiPAP A40 automatically adjusts pressure support to maintain a target tidal volume and when the breath rate is set to Auto, the device will adjust the back-up breath rate based on the patient’s spontaneous respiratory rate.

Page 2: Life made simple Meet the changingc398534.r34.cf1.rackcdn.com/DOCUMENTS/1071960... · *Clinical guidelines recommend that COPD patients should use oxygen therapy for at least 15 hours

Respironics advanced technology in a life support ventilator

Large coloured displaycan be customised to patient

and clinician environment

SD card that stores up to

1 yr ventilation data

Removable air path to meet high level

disinfection standards

3 to 4 hrs internal battery life plus 3 to 4 hrs detachable battery life

3 circuit types

O2 connection low pressure,

up to 15 L/min

Close patient follow-up for long-term efficacy

SD card to store up to 1 year ventilation data.Direct connection to Alice PDx

and Alice5 polysomnographs.

DirectView software to accurately and

efficiently follow patient ventilation.

DirectViewThe Trilogy Series are fitted with a SD card that stores all necessary ventilation data. This data is analized by DirectView software, which manages patient ventilation therapy and identifies when any adjustments are necessary to maintain an effective treatment. DirectView also offers a complete set of ventilation reports that are fully customizable depending on the practice and/or patient’s disease. Furthermore, ventilation data can be exported for supplementary analysis in a number of statistical applications, including Microsoft Excel.

DirectView provides a complete view into respiratory therapy for improved patient care:• 72 hours of raw data to monitor a patient’s

breath-by-breath waveform• Daily details, displaying the patient’s

therapy for the past 30 days• Trend overviews of the past 12 months

displaying pressure, breath rate, percentage of triggered breaths, peak inspiratory patient flow, estimated exhaled tidal volume, leak, Ti/Ttot, minute ventilation and SpO2 (when connected to the oxymetry kit)

Trilogy Series, through direct connection to Alice PDx and Alice5, provides detailed information on patient ventilation in parallel with polysomnograph signals (SpO2, EMG, ECG, etc.).

Digital Auto-TRAK provides automatic trigger

adjustment to meet the changing breathing

patterns and optimise patient–ventilator

synchronisation.

AVAPS hybrid ventilation automatically adjusts

pressure to compensate for changing workloads

of patient ventilation and provides an average

tidal volume.

Patient circuit configurations Passive• circuit with passive exhalation port

Active with PAP• circuit with active exhalation valve

and proximal pressure line

Active with FLOW• circuit with active exhalation valve

and proximal flow sensor

AVAPS hybrid ventilation Digital Auto-TRAK algorithm

The Trilogy Series, versatile life support ventilators developed by Philips Respironics - an innovator of bi-level technology, combines unique levels of flexibility with ease of use and advanced technology to revolutionise the management of respiratory related diseases.

Trilogy100 and Trilogy200, unique features for unique patients

VersatilityAdapting to both patient and clinician environments, the Trilogy series fits with a circuit with a leak (‘Passive Circuit’) or a circuit with a Valve (‘Active circuit with PAP’ and ‘Active circuit with Flow’*) delivering for all configurations volume control or pressure control ventilations, through either non-invasive or invasive interfaces to meet the needs of adult and pediatric patients (> 5 kg) alike.

This built-in flexibility means the Trilogy Series can treat a wide range of respiratory conditions, including those that require frequent changes to the patient’s prescription.

*‘Active with Flow’ circuit type is available in the Trilogy200 only.

PerformanceWhen configured with the passive circuit, the Trilogy Series provides the following Philips Respironics well known technologies:

• Advanced leak compensation in invasive and non-invasive ventilation for pressure modes, as well as – for the first time ever – volume modes.

• Auto-TRAK algorithm providing automatic trigger and cycle thresholds to maintain optimum sensitivity eliminating the need for adjustments.

• AVAPS (Average Volume Assured Pressure Support) hybrid ventilation in pressure modes for invasive and non-invasive modalities.

The Trilogy200 fits with a circuit type ‘Active With Flow’ using a single limb circuit with an active exhalation valve and a proximal flow sensor. This proximal flow sensor allows accurate exhaled gas measurement as well as advanced flow triggering sensitivity and leak compensation for the most difficult patients.

SimplicityWhether it’s being used for hospital titration or in the home, the Trilogy Series have an intuitive interface that combines ease of use with access to high levels of versatility and performance.

The Trilogy Series portable ventilators offer up to 6 to 8 hours battery capacity for continuous autonomy, giving patients the freedom they deserve.

Advanced triggering sensitivity for the most

difficult patients.

In-use bag specifically designed for adaptation

on wheelchair.

Hot swap detachable battery for

continuous autonomy.

Leak estimation and compensation

Both Auto-TRAK and Flow triggering leverage on

leak estimation and compensation to provide the

highest trigger sensitivity. Leak estimation also allows

exhaled tidal volume estimation in passive circuit.

In Trilogy100In Trilogy200

In Trilogy100In Trilogy200

In Trilogy200

Page 3: Life made simple Meet the changingc398534.r34.cf1.rackcdn.com/DOCUMENTS/1071960... · *Clinical guidelines recommend that COPD patients should use oxygen therapy for at least 15 hours

Respironics advanced technology in a life support ventilator

Large coloured displaycan be customised to patient

and clinician environment

SD card that stores up to

1 yr ventilation data

Removable air path to meet high level

disinfection standards

3 to 4 hrs internal battery life plus 3 to 4 hrs detachable battery life

3 circuit types

O2 connection low pressure,

up to 15 L/min

Close patient follow-up for long-term efficacy

SD card to store up to 1 year ventilation data.Direct connection to Alice PDx

and Alice5 polysomnographs.

DirectView software to accurately and

efficiently follow patient ventilation.

DirectViewThe Trilogy Series are fitted with a SD card that stores all necessary ventilation data. This data is analized by DirectView software, which manages patient ventilation therapy and identifies when any adjustments are necessary to maintain an effective treatment. DirectView also offers a complete set of ventilation reports that are fully customizable depending on the practice and/or patient’s disease. Furthermore, ventilation data can be exported for supplementary analysis in a number of statistical applications, including Microsoft Excel.

DirectView provides a complete view into respiratory therapy for improved patient care:• 72 hours of raw data to monitor a patient’s

breath-by-breath waveform• Daily details, displaying the patient’s

therapy for the past 30 days• Trend overviews of the past 12 months

displaying pressure, breath rate, percentage of triggered breaths, peak inspiratory patient flow, estimated exhaled tidal volume, leak, Ti/Ttot, minute ventilation and SpO2 (when connected to the oxymetry kit)

Trilogy Series, through direct connection to Alice PDx and Alice5, provides detailed information on patient ventilation in parallel with polysomnograph signals (SpO2, EMG, ECG, etc.).

Digital Auto-TRAK provides automatic trigger

adjustment to meet the changing breathing

patterns and optimise patient–ventilator

synchronisation.

AVAPS hybrid ventilation automatically adjusts

pressure to compensate for changing workloads

of patient ventilation and provides an average

tidal volume.

Patient circuit configurations Passive• circuit with passive exhalation port

Active with PAP• circuit with active exhalation valve

and proximal pressure line

Active with FLOW• circuit with active exhalation valve

and proximal flow sensor

AVAPS hybrid ventilation Digital Auto-TRAK algorithm

The Trilogy Series, versatile life support ventilators developed by Philips Respironics - an innovator of bi-level technology, combines unique levels of flexibility with ease of use and advanced technology to revolutionise the management of respiratory related diseases.

Trilogy100 and Trilogy200, unique features for unique patients

VersatilityAdapting to both patient and clinician environments, the Trilogy series fits with a circuit with a leak (‘Passive Circuit’) or a circuit with a Valve (‘Active circuit with PAP’ and ‘Active circuit with Flow’*) delivering for all configurations volume control or pressure control ventilations, through either non-invasive or invasive interfaces to meet the needs of adult and pediatric patients (> 5 kg) alike.

This built-in flexibility means the Trilogy Series can treat a wide range of respiratory conditions, including those that require frequent changes to the patient’s prescription.

*‘Active with Flow’ circuit type is available in the Trilogy200 only.

PerformanceWhen configured with the passive circuit, the Trilogy Series provides the following Philips Respironics well known technologies:

• Advanced leak compensation in invasive and non-invasive ventilation for pressure modes, as well as – for the first time ever – volume modes.

• Auto-TRAK algorithm providing automatic trigger and cycle thresholds to maintain optimum sensitivity eliminating the need for adjustments.

• AVAPS (Average Volume Assured Pressure Support) hybrid ventilation in pressure modes for invasive and non-invasive modalities.

The Trilogy200 fits with a circuit type ‘Active With Flow’ using a single limb circuit with an active exhalation valve and a proximal flow sensor. This proximal flow sensor allows accurate exhaled gas measurement as well as advanced flow triggering sensitivity and leak compensation for the most difficult patients.

SimplicityWhether it’s being used for hospital titration or in the home, the Trilogy Series have an intuitive interface that combines ease of use with access to high levels of versatility and performance.

The Trilogy Series portable ventilators offer up to 6 to 8 hours battery capacity for continuous autonomy, giving patients the freedom they deserve.

Advanced triggering sensitivity for the most

difficult patients.

In-use bag specifically designed for adaptation

on wheelchair.

Hot swap detachable battery for

continuous autonomy.

Leak estimation and compensation

Both Auto-TRAK and Flow triggering leverage on

leak estimation and compensation to provide the

highest trigger sensitivity. Leak estimation also allows

exhaled tidal volume estimation in passive circuit.

In Trilogy100In Trilogy200

In Trilogy100In Trilogy200

In Trilogy200

Page 4: Life made simple Meet the changingc398534.r34.cf1.rackcdn.com/DOCUMENTS/1071960... · *Clinical guidelines recommend that COPD patients should use oxygen therapy for at least 15 hours

Respironics advanced technology in a life support ventilator

Large coloured displaycan be customised to patient

and clinician environment

SD card that stores up to

1 yr ventilation data

Removable air path to meet high level

disinfection standards

3 to 4 hrs internal battery life plus 3 to 4 hrs detachable battery life

3 circuit types

O2 connection low pressure,

up to 15 L/min

Close patient follow-up for long-term efficacy

SD card to store up to 1 year ventilation data.Direct connection to Alice PDx

and Alice5 polysomnographs.

DirectView software to accurately and

efficiently follow patient ventilation.

DirectViewThe Trilogy Series are fitted with a SD card that stores all necessary ventilation data. This data is analized by DirectView software, which manages patient ventilation therapy and identifies when any adjustments are necessary to maintain an effective treatment. DirectView also offers a complete set of ventilation reports that are fully customizable depending on the practice and/or patient’s disease. Furthermore, ventilation data can be exported for supplementary analysis in a number of statistical applications, including Microsoft Excel.

DirectView provides a complete view into respiratory therapy for improved patient care:• 72 hours of raw data to monitor a patient’s

breath-by-breath waveform• Daily details, displaying the patient’s

therapy for the past 30 days• Trend overviews of the past 12 months

displaying pressure, breath rate, percentage of triggered breaths, peak inspiratory patient flow, estimated exhaled tidal volume, leak, Ti/Ttot, minute ventilation and SpO2 (when connected to the oxymetry kit)

Trilogy Series, through direct connection to Alice PDx and Alice5, provides detailed information on patient ventilation in parallel with polysomnograph signals (SpO2, EMG, ECG, etc.).

Digital Auto-TRAK provides automatic trigger

adjustment to meet the changing breathing

patterns and optimise patient–ventilator

synchronisation.

AVAPS hybrid ventilation automatically adjusts

pressure to compensate for changing workloads

of patient ventilation and provides an average

tidal volume.

Patient circuit configurations Passive• circuit with passive exhalation port

Active with PAP• circuit with active exhalation valve

and proximal pressure line

Active with FLOW• circuit with active exhalation valve

and proximal flow sensor

AVAPS hybrid ventilation Digital Auto-TRAK algorithm

The Trilogy Series, versatile life support ventilators developed by Philips Respironics - an innovator of bi-level technology, combines unique levels of flexibility with ease of use and advanced technology to revolutionise the management of respiratory related diseases.

Trilogy100 and Trilogy200, unique features for unique patients

VersatilityAdapting to both patient and clinician environments, the Trilogy series fits with a circuit with a leak (‘Passive Circuit’) or a circuit with a Valve (‘Active circuit with PAP’ and ‘Active circuit with Flow’*) delivering for all configurations volume control or pressure control ventilations, through either non-invasive or invasive interfaces to meet the needs of adult and pediatric patients (> 5 kg) alike.

This built-in flexibility means the Trilogy Series can treat a wide range of respiratory conditions, including those that require frequent changes to the patient’s prescription.

*‘Active with Flow’ circuit type is available in the Trilogy200 only.

PerformanceWhen configured with the passive circuit, the Trilogy Series provides the following Philips Respironics well known technologies:

• Advanced leak compensation in invasive and non-invasive ventilation for pressure modes, as well as – for the first time ever – volume modes.

• Auto-TRAK algorithm providing automatic trigger and cycle thresholds to maintain optimum sensitivity eliminating the need for adjustments.

• AVAPS (Average Volume Assured Pressure Support) hybrid ventilation in pressure modes for invasive and non-invasive modalities.

The Trilogy200 fits with a circuit type ‘Active With Flow’ using a single limb circuit with an active exhalation valve and a proximal flow sensor. This proximal flow sensor allows accurate exhaled gas measurement as well as advanced flow triggering sensitivity and leak compensation for the most difficult patients.

SimplicityWhether it’s being used for hospital titration or in the home, the Trilogy Series have an intuitive interface that combines ease of use with access to high levels of versatility and performance.

The Trilogy Series portable ventilators offer up to 6 to 8 hours battery capacity for continuous autonomy, giving patients the freedom they deserve.

Advanced triggering sensitivity for the most

difficult patients.

In-use bag specifically designed for adaptation

on wheelchair.

Hot swap detachable battery for

continuous autonomy.

Leak estimation and compensation

Both Auto-TRAK and Flow triggering leverage on

leak estimation and compensation to provide the

highest trigger sensitivity. Leak estimation also allows

exhaled tidal volume estimation in passive circuit.

In Trilogy100In Trilogy200

In Trilogy100In Trilogy200

In Trilogy200

Page 5: Life made simple Meet the changingc398534.r34.cf1.rackcdn.com/DOCUMENTS/1071960... · *Clinical guidelines recommend that COPD patients should use oxygen therapy for at least 15 hours

Philips Healthcare is part of Royal Philips Electronics

How to reach uswww.philips.com/[email protected]: +31 40 27 64 887

Asia+852 2821 5888

Europe, Middle East, Africa+49 7031 463 2254

Latin America+55 11 2125 0744

North America+1 425 487 7000800 285 5585 (toll free, US only)

© 2012 Koninklijke Philips Electronics N.V. All rights are reserved.

Philips Healthcare reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. Broudy NA 09/14/12 MCI 4104848 PN 1071960

Philips Respironics1010 Murry Ridge LaneMurrysville, PA 15668

Customer Service+1 724 387 4000800 345 6443 (toll free, US only)

Respironics Asia Pacific+65 6882 5282

Respironics Australia+61 (2) 9666 4444

Respironics Deutschland+49 8152 93 06 0

Respironics Europe, Middle East, Africa+33 1 47 52 30 00

Respironics France+33 2 51 89 36 00

Respironics Italy+39 039 203 1

Respironics Sweden+46 8 120 45 900

Respironics Switzerland+41 6 27 45 17 50

Respironics United Kingdom+44 800 1300 845

www.philips.com/respironics

Product specifications

Ventilation modes

• Pressure modes (CPAP, S, ST, PC, T, PC-SIMV)

• Volume modes (AC, CV, SIMV)• AVAPS hybrid ventilation (only with passive exhalation port circuit)• Dual prescription• Invasive and non-invasive capabilities• For adults and children (> 5 kg)

Circuit configurations

• Passive exhalation port circuit• Active exhalation valve circuit with proximal

pressure line• Active exhalation valve circuit with proximal

flow sensor (available on the Trilogy200 only)

Triggers • Auto-TRAK sensitivity (only with passive exhalation port circuit)

• Adjustable flow triggers

IPAP • 4 to 50 cmH2O

EPAP • 0 to 25 cmH2O with active exhalation valve• 4 to 25 cmH2O with passive exhalation port

PEEP • 0 to 25 cmH2O with active exhalation valve• 4 to 25 cmH2O with passive exhalation port

Pressure support

• 0 to 30 cmH2O

Tidal volume • 50 to 2000 ml

Breath rate • Up to 60 BPM

Inspiratory time

• 0.3 to 3 seconds

Rise time • 1 (100 ms) to 6 (600 ms)

O2 inlet • Back of the device (low pressure) up to 15 L/min

Size • 16 (L) x 28 (W) x 23 (H)

Weight • 5 kg (with detachable battery)

Customizable user-interface

• Full detailed configuration for hospital use• Limited detailed configuration for home use

Bags • Carrying bag• In-use bag

Settable alarms • Patient disconnection• Apnoea• Low/high tidal volume• Low/high minute ventilation• Low/high respiratory rate• Low/high inspiratory pressure

(in volume modes)• Low SpO2*

Monitoring • Exhaled tidal volume• Exhaled minute ventilation• Leak rate• Respiratory rate• Peak inspiratory flow• Peak inspiratory pressure• I:E ratio• Mean airway pressure• SpO2*

Battery • Internal battery: 3 to 4 hours• Detachable battery: 3 to 4 hours• External battery connection : 12 VDC

Data management

• DirectView software• 1 GB SD card data storage

Polygraph & Polysomnographconnections

• Direct connection to Alice PDx and Alice 5 PSG

• AOM to connect to most PSG systems

Simple ventilation, sophisticated technology

Circuit typePassive Active with PAP Active with Flow

Ventilation type Volume and pressure modes for non-invasive and invasive modalitiesMinimum PEP of 4 required Allows 0 PEP Allows 0 PEP

Leak compensation Exceptional Good Very goodTriggering Auto-TRAK & Flow Flow Advanced flow triggeringExhaled gas monitoring Estimation — Measurement

Trilogy100 ✓ ✓ —

Trilogy200 ✓ ✓ ✓

* When SpO2 module connected using the Trilogy SPO2 cable: PN 1080964

Trilogy100, Trilogy200, DirectView, Auto-TRAK, AVAPS, Alice 5 and Alice PDx are trademarks of Respironics, Inc. and its affiliates. Microsoft and Excel are registered trademarks of Microsoft Corporation.

Meet the changing needs of your patients Trilogy Series, with advanced ventilator technology

Life made simple

©2012 Koninklijke Philips Electronics N.V. All rights reserved.Philips Healthcare reserves the right to make changes in specifications and/or to discontinue any product at any time without noticeor obligation and will not be liable for any consequences resulting from the use of this publication.

CAUTION: US federal law restricts these devices to sale by or on the order of a physician.

Respironics, FitLife, and EZ Peel are trademarks of Respironics, Inc. and its affiliates.

Broudy AE 5/21/12 MCI 4104723 PN 1098670

Notes*Clinical guidelines recommend that COPD patients should use oxygen therapy for at least 15 hours perday to have positive effects on their long term survival and their quality of life. Therefore these patientsrequire oxygen at home (stationary oxygen therapy) and outside (ambulatory oxygen therapy).

SimplyGo - reliability andmaintenance made simple!

Built-in reliabilitySimplyGo strives to set a new standard in portable concentrators’ reliability. SimplyGo has been designed, built, and rigorously tested towithstand the stress of everyday life when following patientsanytime, anywhere.

During development, SimplyGo was subjected to extreme conditionsincluding impact, vibrations, and temperature extremes to test reliableperformance day-in and day-out.With 15000 hours of compressor lifetime, its performance is trustworthy. This may mean fewer callbacks for you and fewer frustrations for your patients due to accidental damage.

You can count on SimplyGo.

COPD (chronic obstructive pulmonary disease) patients are dependent on oxygen therapyequipment that they need for many hours* a day. SimplyGo offers the independence and freedompatients want in a durable design that can resist the bumps and bruises of daily activities whileproviding an effective therapy.

Please visit www.philips.com/respironics

Philips Healthcare is part of Royal Philips Electronics

How to reach uswww.philips.com/[email protected]

Asia+49 7031 463 2254

Europe, Middle East, Africa+49 7031 463 2254

Latin America+55 11 2125 0744

North America+1 425 487 7000 800 285 5585 (toll free, US only)

Philips Respironics Deutschland+49 8152 93 06 0

Philips Respironics France+33 2 51 89 36 00

Philips Respironics Italy+39 039 203 1

Philips Respironics Sweden+46 8 120 45 900

Philips Respironics Switzerland +41 6 27 45 17 50

Philips Respironics United Kingdom+44 800 1300 845

www.philips.com/respironics

Philips Respironics1010 Murry Ridge LaneMurrysville, PA 15668

Customer Sevice+1 724 387 4000800 345 6443 (toll free, US only)

Philips Respironics InternationalHeadquarters+33 1 47 28 30 82

Philips Respironics Asia Pacific +65 6882 5282

Philips Respironics Australia+61 (2) 9947 04401300 766 488 (toll free,Australia only)

Philips Respironics China+86 400 828 6665+86 800 828 6665

Contact us

Maintenance made simple!SimplyGo makes it easy for providers, as it requires virtuallyno preventive or patient maintenance.

SimplyGo is flexible:• Make a choice between two-, three-, or five-year warranty.

Pick the plan that’s best for your service.

• SimplyGo’s easily accessible parts and comprehensive service tools allow your technicians to service the device in-house instead of returning it to the manufacturer.

Philips Respironics SimplyGo portable oxygen concentrator - simplychanges your patient’s life

Respironics, SimplyGo, and EverFlow are trademarks of Respironics, Inc. and its affiliates.All rights reserved.

© 2012 Koninklijke Philips Electronics N.V. All rights are reserved.

Philips Healthcare reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication.

Broudy AE 9/12/12 MCI 4105036 PN 1102086

Please visit www.philips.com/respironics

Philips Healthcare is part of Royal Philips Electronics

Philips Respironics International Headquarters+33 1 47 28 30 82 Philips Respironics Asia Pacific+65 6882 5282Philips Home Healthcare Solutions Australia+61 (2) 9947 0440Philips Respironics United Kingdom+44 800 1300 845

Respironics New Jersey. Inc.5 Wood Hollow RoadParsippany, NJ 07054 USA

Customer Service+1 724 387 4000800 345 6443 (toll free, US only)www.philips.com/respironics

AVAPS-AE mode

Product specificationsVentilation modes •CPAP•S•S/T•PC•T•AVAPS-AEHybrid ventilation •AVAPS (Average Volume Assured Pressure Support)

•AVAPS-AEIPAP 4 – 40 cmH2OEPAP 4 – 25 cmH2OTarget tidal volume (AVAPS & AVAPS-AE)

200 – 1500 ml

Breath rate 0 – 40 bpm (4 – 40 bpm in T mode)Inspiratory time 0.5 – 3 sec.Triggering and cycling •Auto-Trak

•Sensitive Auto-Trak•Flow triggering

Rise time 1 (100 ms) – 6 (600 ms)Size 21.6 cm W x 19 cm L x 11.5 cm HWeight 2.1 kgs (with power supply)Noise level < 30 dBA at 10 cmH2OHumidification System One humidity control and ‘Dry Box’ technologyAlarms •Patientdisconnection

•Apnea •Lowminuteventilation •Lowtidalvolume(withAVAPS/AVAPS-AEonly) •Highrespiratoryrate

Monitoring •Pressure•Tidalvolume•Minuteventilation •Respiratoryrate•Leak•I/Eratio

Battery back up Detachable battery module: 5 hours at IPAP 12 cmH2O / EPAP 7 cmH2O and 12 bpm

DC power source •12VDC,5.0A(externalbattery) •24VDC,4.2A(powersupply)

Data management •EncorePro 2 and DirectView software•Compatible with oximetry module•Advanced detection of residual respiratory events

(apnea/hypopnea index, obstructed airway apnea, clear airway apnea, hypopnea, periodic breathing, RERA, large leak and snore)

Remote control Compatible with PC DirectPolygraph and polysomnograph connections

•Direct connection to Alice PDx and Alice6 PSGs•AOM to connect to most PSG systems

BiPAP A40, Auto-Trak, AVAPS, AVAPS-AE, EncorePro, DirectView, and Alice are trademarks of Koninklijke Philips Electronics N.V. All rights are reserved.

Ordering information Part no.DevicesBiPAP A40, International * 1076493BiPAP A40, Australia * 1076583* contains BiPAP A40 ventilator with SD card, power cord,

AC power adapter, user manual, ultra fine filter, grey foam filter, tubing, and carrying case

AccessoriesA Series humidifier, International 1077107 Battery module 1096770Detachable battery 1043570Ultra fine filter kit 1063096 Foam filter kit 1063091Power supply 1081167Power cord, Europe 1039014Power cord, UK 1039026Performance tubing 22 mm 1032907Performance tubing 15 mm 1074400EncorePro 2 software 1054785DirectView software 1005297RJ9 to 1/4” nurse call cable, closed 1080247RJ9 to 1/4” nurse call cable, open 1080248RJ9 nurse call cable, open ends 1080249Carrying bag 1098514BiPAP A40 in-use bag 1098513Oximetry accessory, INTL 100215EBiPAP A Series roll stand 1098538

In AVAPS-AE mode, the device monitors the patient’s upper airway resistance and automatically adjusts the delivered EPAP required to maintain an airway. Simultaneously, BiPAP A40 automatically adjusts pressure support to maintain a target tidal volume and when the breath rate is set to Auto, the device will adjust the back-up breath rate based on the patient’s spontaneous respiratory rate.

© 2012 Koninklijke Philips Electronics N.V. All rights are reserved.

Philips Healthcare reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication.

Broudy AE 9/12/12 MCI 4105036 PN 1102086

Please visit www.philips.com/respironics

Philips Healthcare is part of Royal Philips Electronics

Philips Respironics International Headquarters+33 1 47 28 30 82 Philips Respironics Asia Pacific+65 6882 5282Philips Home Healthcare Solutions Australia+61 (2) 9947 0440Philips Respironics United Kingdom+44 800 1300 845

Respironics New Jersey. Inc.5 Wood Hollow RoadParsippany, NJ 07054 USA

Customer Service+1 724 387 4000800 345 6443 (toll free, US only)www.philips.com/respironics

AVAPS-AE mode

Product specificationsVentilation modes •CPAP•S•S/T•PC•T•AVAPS-AEHybrid ventilation •AVAPS (Average Volume Assured Pressure Support)

•AVAPS-AEIPAP 4 – 40 cmH2OEPAP 4 – 25 cmH2OTarget tidal volume (AVAPS & AVAPS-AE)

200 – 1500 ml

Breath rate 0 – 40 bpm (4 – 40 bpm in T mode)Inspiratory time 0.5 – 3 sec.Triggering and cycling •Auto-Trak

•Sensitive Auto-Trak•Flow triggering

Rise time 1 (100 ms) – 6 (600 ms)Size 21.6 cm W x 19 cm L x 11.5 cm HWeight 2.1 kgs (with power supply)Noise level < 30 dBA at 10 cmH2OHumidification System One humidity control and ‘Dry Box’ technologyAlarms •Patientdisconnection

•Apnea •Lowminuteventilation •Lowtidalvolume(withAVAPS/AVAPS-AEonly) •Highrespiratoryrate

Monitoring •Pressure•Tidalvolume•Minuteventilation •Respiratoryrate•Leak•I/Eratio

Battery back up Detachable battery module: 5 hours at IPAP 12 cmH2O / EPAP 7 cmH2O and 12 bpm

DC power source •12VDC,5.0A(externalbattery) •24VDC,4.2A(powersupply)

Data management •EncorePro 2 and DirectView software•Compatible with oximetry module•Advanced detection of residual respiratory events

(apnea/hypopnea index, obstructed airway apnea, clear airway apnea, hypopnea, periodic breathing, RERA, large leak and snore)

Remote control Compatible with PC DirectPolygraph and polysomnograph connections

•Direct connection to Alice PDx and Alice6 PSGs•AOM to connect to most PSG systems

BiPAP A40, Auto-Trak, AVAPS, AVAPS-AE, EncorePro, DirectView, and Alice are trademarks of Koninklijke Philips Electronics N.V. All rights are reserved.

Ordering information Part no.DevicesBiPAP A40, International * 1076493BiPAP A40, Australia * 1076583* contains BiPAP A40 ventilator with SD card, power cord,

AC power adapter, user manual, ultra fine filter, grey foam filter, tubing, and carrying case

AccessoriesA Series humidifier, International 1077107 Battery module 1096770Detachable battery 1043570Ultra fine filter kit 1063096 Foam filter kit 1063091Power supply 1081167Power cord, Europe 1039014Power cord, UK 1039026Performance tubing 22 mm 1032907Performance tubing 15 mm 1074400EncorePro 2 software 1054785DirectView software 1005297RJ9 to 1/4” nurse call cable, closed 1080247RJ9 to 1/4” nurse call cable, open 1080248RJ9 nurse call cable, open ends 1080249Carrying bag 1098514BiPAP A40 in-use bag 1098513Oximetry accessory, INTL 100215EBiPAP A Series roll stand 1098538

In AVAPS-AE mode, the device monitors the patient’s upper airway resistance and automatically adjusts the delivered EPAP required to maintain an airway. Simultaneously, BiPAP A40 automatically adjusts pressure support to maintain a target tidal volume and when the breath rate is set to Auto, the device will adjust the back-up breath rate based on the patient’s spontaneous respiratory rate.

Page 6: Life made simple Meet the changingc398534.r34.cf1.rackcdn.com/DOCUMENTS/1071960... · *Clinical guidelines recommend that COPD patients should use oxygen therapy for at least 15 hours

Philips Healthcare is part of Royal Philips Electronics

How to reach uswww.philips.com/[email protected]: +31 40 27 64 887

Asia+852 2821 5888

Europe, Middle East, Africa+49 7031 463 2254

Latin America+55 11 2125 0744

North America+1 425 487 7000800 285 5585 (toll free, US only)

© 2012 Koninklijke Philips Electronics N.V. All rights are reserved.

Philips Healthcare reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. Broudy NA 09/14/12 MCI 4104848 PN 1071960

Philips Respironics1010 Murry Ridge LaneMurrysville, PA 15668

Customer Service+1 724 387 4000800 345 6443 (toll free, US only)

Respironics Asia Pacific+65 6882 5282

Respironics Australia+61 (2) 9666 4444

Respironics Deutschland+49 8152 93 06 0

Respironics Europe, Middle East, Africa+33 1 47 52 30 00

Respironics France+33 2 51 89 36 00

Respironics Italy+39 039 203 1

Respironics Sweden+46 8 120 45 900

Respironics Switzerland+41 6 27 45 17 50

Respironics United Kingdom+44 800 1300 845

www.philips.com/respironics

Product specifications

Ventilation modes

• Pressure modes (CPAP, S, ST, PC, T, PC-SIMV)

• Volume modes (AC, CV, SIMV)• AVAPS hybrid ventilation (only with passive exhalation port circuit)• Dual prescription• Invasive and non-invasive capabilities• For adults and children (> 5 kg)

Circuit configurations

• Passive exhalation port circuit• Active exhalation valve circuit with proximal

pressure line• Active exhalation valve circuit with proximal

flow sensor (available on the Trilogy200 only)

Triggers • Auto-TRAK sensitivity (only with passive exhalation port circuit)

• Adjustable flow triggers

IPAP • 4 to 50 cmH2O

EPAP • 0 to 25 cmH2O with active exhalation valve• 4 to 25 cmH2O with passive exhalation port

PEEP • 0 to 25 cmH2O with active exhalation valve• 4 to 25 cmH2O with passive exhalation port

Pressure support

• 0 to 30 cmH2O

Tidal volume • 50 to 2000 ml

Breath rate • Up to 60 BPM

Inspiratory time

• 0.3 to 3 seconds

Rise time • 1 (100 ms) to 6 (600 ms)

O2 inlet • Back of the device (low pressure) up to 15 L/min

Size • 16 (L) x 28 (W) x 23 (H)

Weight • 5 kg (with detachable battery)

Customizable user-interface

• Full detailed configuration for hospital use• Limited detailed configuration for home use

Bags • Carrying bag• In-use bag

Settable alarms • Patient disconnection• Apnoea• Low/high tidal volume• Low/high minute ventilation• Low/high respiratory rate• Low/high inspiratory pressure

(in volume modes)• Low SpO2*

Monitoring • Exhaled tidal volume• Exhaled minute ventilation• Leak rate• Respiratory rate• Peak inspiratory flow• Peak inspiratory pressure• I:E ratio• Mean airway pressure• SpO2*

Battery • Internal battery: 3 to 4 hours• Detachable battery: 3 to 4 hours• External battery connection : 12 VDC

Data management

• DirectView software• 1 GB SD card data storage

Polygraph & Polysomnographconnections

• Direct connection to Alice PDx and Alice 5 PSG

• AOM to connect to most PSG systems

Simple ventilation, sophisticated technology

Circuit typePassive Active with PAP Active with Flow

Ventilation type Volume and pressure modes for non-invasive and invasive modalitiesMinimum PEP of 4 required Allows 0 PEP Allows 0 PEP

Leak compensation Exceptional Good Very goodTriggering Auto-TRAK & Flow Flow Advanced flow triggeringExhaled gas monitoring Estimation — Measurement

Trilogy100 ✓ ✓ —

Trilogy200 ✓ ✓ ✓

* When SpO2 module connected using the Trilogy SPO2 cable: PN 1080964

Trilogy100, Trilogy200, DirectView, Auto-TRAK, AVAPS, Alice 5 and Alice PDx are trademarks of Respironics, Inc. and its affiliates. Microsoft and Excel are registered trademarks of Microsoft Corporation.

Meet the changing needs of your patients Trilogy Series, with advanced ventilator technology

Life made simple

©2012 Koninklijke Philips Electronics N.V. All rights reserved.Philips Healthcare reserves the right to make changes in specifications and/or to discontinue any product at any time without noticeor obligation and will not be liable for any consequences resulting from the use of this publication.

CAUTION: US federal law restricts these devices to sale by or on the order of a physician.

Respironics, FitLife, and EZ Peel are trademarks of Respironics, Inc. and its affiliates.

Broudy AE 5/21/12 MCI 4104723 PN 1098670

Notes*Clinical guidelines recommend that COPD patients should use oxygen therapy for at least 15 hours perday to have positive effects on their long term survival and their quality of life. Therefore these patientsrequire oxygen at home (stationary oxygen therapy) and outside (ambulatory oxygen therapy).

SimplyGo - reliability andmaintenance made simple!

Built-in reliabilitySimplyGo strives to set a new standard in portable concentrators’ reliability. SimplyGo has been designed, built, and rigorously tested towithstand the stress of everyday life when following patientsanytime, anywhere.

During development, SimplyGo was subjected to extreme conditionsincluding impact, vibrations, and temperature extremes to test reliableperformance day-in and day-out.With 15000 hours of compressor lifetime, its performance is trustworthy. This may mean fewer callbacks for you and fewer frustrations for your patients due to accidental damage.

You can count on SimplyGo.

COPD (chronic obstructive pulmonary disease) patients are dependent on oxygen therapyequipment that they need for many hours* a day. SimplyGo offers the independence and freedompatients want in a durable design that can resist the bumps and bruises of daily activities whileproviding an effective therapy.

Please visit www.philips.com/respironics

Philips Healthcare is part of Royal Philips Electronics

How to reach uswww.philips.com/[email protected]

Asia+49 7031 463 2254

Europe, Middle East, Africa+49 7031 463 2254

Latin America+55 11 2125 0744

North America+1 425 487 7000 800 285 5585 (toll free, US only)

Philips Respironics Deutschland+49 8152 93 06 0

Philips Respironics France+33 2 51 89 36 00

Philips Respironics Italy+39 039 203 1

Philips Respironics Sweden+46 8 120 45 900

Philips Respironics Switzerland +41 6 27 45 17 50

Philips Respironics United Kingdom+44 800 1300 845

www.philips.com/respironics

Philips Respironics1010 Murry Ridge LaneMurrysville, PA 15668

Customer Sevice+1 724 387 4000800 345 6443 (toll free, US only)

Philips Respironics InternationalHeadquarters+33 1 47 28 30 82

Philips Respironics Asia Pacific +65 6882 5282

Philips Respironics Australia+61 (2) 9947 04401300 766 488 (toll free,Australia only)

Philips Respironics China+86 400 828 6665+86 800 828 6665

Contact us

Maintenance made simple!SimplyGo makes it easy for providers, as it requires virtuallyno preventive or patient maintenance.

SimplyGo is flexible:• Make a choice between two-, three-, or five-year warranty. Pick the plan that’s best for your service.

• SimplyGo’s easily accessible parts and comprehensive service tools allow your technicians to service the device in-house instead of returning it to the manufacturer.

Philips Respironics SimplyGo portable oxygen concentrator - simplychanges your patient’s life

Respironics, SimplyGo, and EverFlow are trademarks of Respironics, Inc. and its affiliates.All rights reserved.

© 2012 Koninklijke Philips Electronics N.V. All rights are reserved.

Philips Healthcare reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication.

Broudy AE 9/12/12 MCI 4105036 PN 1102086

Please visit www.philips.com/respironics

Philips Healthcare is part of Royal Philips Electronics

Philips Respironics International Headquarters+33 1 47 28 30 82 Philips Respironics Asia Pacific+65 6882 5282Philips Home Healthcare Solutions Australia+61 (2) 9947 0440Philips Respironics United Kingdom+44 800 1300 845

Respironics New Jersey. Inc.5 Wood Hollow RoadParsippany, NJ 07054 USA

Customer Service+1 724 387 4000800 345 6443 (toll free, US only)www.philips.com/respironics

AVAPS-AE mode

Product specificationsVentilation modes •CPAP•S•S/T•PC•T•AVAPS-AEHybrid ventilation •AVAPS (Average Volume Assured Pressure Support)

•AVAPS-AEIPAP 4 – 40 cmH2OEPAP 4 – 25 cmH2OTarget tidal volume (AVAPS & AVAPS-AE)

200 – 1500 ml

Breath rate 0 – 40 bpm (4 – 40 bpm in T mode)Inspiratory time 0.5 – 3 sec.Triggering and cycling •Auto-Trak

•Sensitive Auto-Trak•Flow triggering

Rise time 1 (100 ms) – 6 (600 ms)Size 21.6 cm W x 19 cm L x 11.5 cm HWeight 2.1 kgs (with power supply)Noise level < 30 dBA at 10 cmH2OHumidification System One humidity control and ‘Dry Box’ technologyAlarms •Patientdisconnection

•Apnea •Lowminuteventilation •Lowtidalvolume(withAVAPS/AVAPS-AEonly) •Highrespiratoryrate

Monitoring •Pressure•Tidalvolume•Minuteventilation •Respiratoryrate•Leak•I/Eratio

Battery back up Detachable battery module: 5 hours at IPAP 12 cmH2O / EPAP 7 cmH2O and 12 bpm

DC power source •12VDC,5.0A(externalbattery) •24VDC,4.2A(powersupply)

Data management •EncorePro 2 and DirectView software•Compatible with oximetry module•Advanced detection of residual respiratory events

(apnea/hypopnea index, obstructed airway apnea, clear airway apnea, hypopnea, periodic breathing, RERA, large leak and snore)

Remote control Compatible with PC DirectPolygraph and polysomnograph connections

•Direct connection to Alice PDx and Alice6 PSGs•AOM to connect to most PSG systems

BiPAP A40, Auto-Trak, AVAPS, AVAPS-AE, EncorePro, DirectView, and Alice are trademarks of Koninklijke Philips Electronics N.V. All rights are reserved.

Ordering information Part no.DevicesBiPAP A40, International * 1076493BiPAP A40, Australia * 1076583* contains BiPAP A40 ventilator with SD card, power cord,

AC power adapter, user manual, ultra fine filter, grey foam filter, tubing, and carrying case

AccessoriesA Series humidifier, International 1077107 Battery module 1096770Detachable battery 1043570Ultra fine filter kit 1063096 Foam filter kit 1063091Power supply 1081167Power cord, Europe 1039014Power cord, UK 1039026Performance tubing 22 mm 1032907Performance tubing 15 mm 1074400EncorePro 2 software 1054785DirectView software 1005297RJ9 to 1/4” nurse call cable, closed 1080247RJ9 to 1/4” nurse call cable, open 1080248RJ9 nurse call cable, open ends 1080249Carrying bag 1098514BiPAP A40 in-use bag 1098513Oximetry accessory, INTL 100215EBiPAP A Series roll stand 1098538

In AVAPS-AE mode, the device monitors the patient’s upper airway resistance and automatically adjusts the delivered EPAP required to maintain an airway. Simultaneously, BiPAP A40 automatically adjusts pressure support to maintain a target tidal volume and when the breath rate is set to Auto, the device will adjust the back-up breath rate based on the patient’s spontaneous respiratory rate.

© 2012 Koninklijke Philips Electronics N.V. All rights are reserved.

Philips Healthcare reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication.

Broudy AE 9/12/12 MCI 4105036 PN 1102086

Please visit www.philips.com/respironics

Philips Healthcare is part of Royal Philips Electronics

Philips Respironics International Headquarters+33 1 47 28 30 82 Philips Respironics Asia Pacific+65 6882 5282Philips Home Healthcare Solutions Australia+61 (2) 9947 0440Philips Respironics United Kingdom+44 800 1300 845

Respironics New Jersey. Inc.5 Wood Hollow RoadParsippany, NJ 07054 USA

Customer Service+1 724 387 4000800 345 6443 (toll free, US only)www.philips.com/respironics

AVAPS-AE mode

Product specificationsVentilation modes •CPAP•S•S/T•PC•T•AVAPS-AEHybrid ventilation •AVAPS (Average Volume Assured Pressure Support)

•AVAPS-AEIPAP 4 – 40 cmH2OEPAP 4 – 25 cmH2OTarget tidal volume (AVAPS & AVAPS-AE)

200 – 1500 ml

Breath rate 0 – 40 bpm (4 – 40 bpm in T mode)Inspiratory time 0.5 – 3 sec.Triggering and cycling •Auto-Trak

•Sensitive Auto-Trak•Flow triggering

Rise time 1 (100 ms) – 6 (600 ms)Size 21.6 cm W x 19 cm L x 11.5 cm HWeight 2.1 kgs (with power supply)Noise level < 30 dBA at 10 cmH2OHumidification System One humidity control and ‘Dry Box’ technologyAlarms •Patientdisconnection

•Apnea •Lowminuteventilation •Lowtidalvolume(withAVAPS/AVAPS-AEonly) •Highrespiratoryrate

Monitoring •Pressure•Tidalvolume•Minuteventilation •Respiratoryrate•Leak•I/Eratio

Battery back up Detachable battery module: 5 hours at IPAP 12 cmH2O / EPAP 7 cmH2O and 12 bpm

DC power source •12VDC,5.0A(externalbattery) •24VDC,4.2A(powersupply)

Data management •EncorePro 2 and DirectView software•Compatible with oximetry module•Advanced detection of residual respiratory events

(apnea/hypopnea index, obstructed airway apnea, clear airway apnea, hypopnea, periodic breathing, RERA, large leak and snore)

Remote control Compatible with PC DirectPolygraph and polysomnograph connections

•Direct connection to Alice PDx and Alice6 PSGs•AOM to connect to most PSG systems

BiPAP A40, Auto-Trak, AVAPS, AVAPS-AE, EncorePro, DirectView, and Alice are trademarks of Koninklijke Philips Electronics N.V. All rights are reserved.

Ordering information Part no.DevicesBiPAP A40, International * 1076493BiPAP A40, Australia * 1076583* contains BiPAP A40 ventilator with SD card, power cord,

AC power adapter, user manual, ultra fine filter, grey foam filter, tubing, and carrying case

AccessoriesA Series humidifier, International 1077107 Battery module 1096770Detachable battery 1043570Ultra fine filter kit 1063096 Foam filter kit 1063091Power supply 1081167Power cord, Europe 1039014Power cord, UK 1039026Performance tubing 22 mm 1032907Performance tubing 15 mm 1074400EncorePro 2 software 1054785DirectView software 1005297RJ9 to 1/4” nurse call cable, closed 1080247RJ9 to 1/4” nurse call cable, open 1080248RJ9 nurse call cable, open ends 1080249Carrying bag 1098514BiPAP A40 in-use bag 1098513Oximetry accessory, INTL 100215EBiPAP A Series roll stand 1098538

In AVAPS-AE mode, the device monitors the patient’s upper airway resistance and automatically adjusts the delivered EPAP required to maintain an airway. Simultaneously, BiPAP A40 automatically adjusts pressure support to maintain a target tidal volume and when the breath rate is set to Auto, the device will adjust the back-up breath rate based on the patient’s spontaneous respiratory rate.