OI Graphic Configuration
PCLPCLPCLPCL
PACiSPACiSPACiSPACiS TechnicalTechnicalTechnicalTechnical TrainingTrainingTrainingTraining LevelLevelLevelLevel 2 22 2
CS&PCS&PCS&PCS&P – –– – Support Team Support Team Support Team Support Team
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
2/43
Schneider Electric 2- CS&P – OI Graphic Configuration
• Content
SCE OI General Parameters
Display
Active X
Graphical Animation
Users & Rights
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
3/43
Schneider Electric 3- CS&P – OI Graphic Configuration
• Content
SCE OI General Parameters
Display
Active X
Graphical Animation
Users & Rights
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
4/43
Schneider Electric 4- CS&P – OI Graphic Configuration
Reminder
PACiS OI Client
Display viewsSCP
PACiS OI ServerSBUS Acquisition (RP only)
Inner information DIAG, alarm grouping ...Archive and reportsSOE, states logging, alarms loggingPrinting SOE, states, alarmsRights management
OI generationSCE needs XML parser to generate OI filesXML Parser to be installed in root of hard drive (C: or D:…)
S2K Client builder needed only if mimic generation in binary
• PACiS OI definition
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
5/43
Schneider Electric 5- CS&P – OI Graphic Configuration
Graphic menu
Color, Font, Stroke
Why ?
Define general colors, fontsand stroke for configuration.
Flexibility in case of change.
• Color, Font, Stroke Tables
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
6/43
Schneider Electric 6- CS&P – OI Graphic Configuration
19 pre-configured colors
237 configurable colors
• Color Table (1)
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
7/43
Schneider Electric 7- CS&P – OI Graphic Configuration
Attributes of selected color
Example of configured colors
STRONGLY ADVISED to set colors nameto a specific use.
Advantage : easily modifiable
• Color Table (2)
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
8/43
Schneider Electric 8- CS&P – OI Graphic Configuration
Blinking period
Example of configured colors
• Color Table (3)
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
9/43
Schneider Electric 9- CS&P – OI Graphic Configuration
1st possibility :
on Swatches tab,
point directly thecolor
2 extra
possibilities :
HSB (Hue,
Saturation,
Brightness)
RGB (Red, Green,Blue)
• Color Table (4)
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
10/43
Schneider Electric 10- CS&P – OI Graphic Configuration
60 configurable fonts
4 pre-configured fonts
NormalItalic
NormalBold
• Font Table (1)
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
11/43
Schneider Electric 11- CS&P – OI Graphic Configuration
Available fonts :
Times New Roman + list
• Font Table (2)
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
12/43
Schneider Electric 12- CS&P – OI Graphic Configuration
5 pre-configured strokes
59 configurable strokes
• Stroke Table
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
13/43
Schneider Electric 13- CS&P – OI Graphic Configuration
3 Alarm management policies
State Basis
Gravity Level Basis
Data Basis
one alarm for each state is displayed
only one alarm for each gravity level is displayed , the previousone is replaced by the current one with same gravity level
only the last alarm is displayed: the previous one is replaced bythe current one
• Alarm Policy (1)
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
14/43
Schneider Electric 14- CS&P – OI Graphic Configuration
Reminder
The alarm policy is configured under Scs attributes
State BasisGravity Level BasisData Basis
the C264 must not
manage alarms exceptif customer is requiring
• Alarm Policy (2)
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
15/43
Schneider Electric 15- CS&P – OI Graphic Configuration
Graphic Part /tab GravityColors
Alarm status per
gravity
Correspondingcolors
• Alarm Colors
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
16/43
Schneider Electric 16- CS&P – OI Graphic Configuration
Board Names (SMT)
- configured under Scs attributes / Labels tab
Board Names
Boards systemalarm labels
• Board Names
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
17/43
Schneider Electric 17- CS&P – OI Graphic Configuration
Control Messages : configured under Scs attributes / Labels tab
Order Steps (Selected/In
Progress)
Control Acknowledgement :
• General Messages (1)
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
18/43
Schneider Electric 18- CS&P – OI Graphic Configuration
Time stamping Messages : configured under Scs attributes / Labels tab
Symbols appearing in viewers, printers
• General Messages (2)
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
19/43
Schneider Electric 19- CS&P – OI Graphic Configuration
• Content
SCE OI General Parameters
DisplayActive X
Graphical Animation
Users & Rights
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
20/43
Schneider Electric 20- CS&P – OI Graphic Configuration
Under Graphic Part
Workspaces sizes
• OI Workspaces
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
21/43
Schneider Electric 21- CS&P – OI Graphic Configuration
Wnd 1,2 and 5predeterminated
Mimics
Windowpositionning
Windows options
• OI Windows
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
22/43
Schneider Electric 22- CS&P – OI Graphic Configuration
PossibleComponents :
ActiveX, Symbol
Possible Relation :
Viewing right
Window
positionning
Windows options
• OI Mimics
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
23/43
Schneider Electric 23- CS&P – OI Graphic Configuration
• Content
SCE OI General Parameters
DisplayActive X
Graphical Animation
Users & Rights
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
24/43
Schneider Electric 24- CS&P – OI Graphic Configuration
General tab
Windowpositioning
Windows options
Printer Name
Local OI Server
• Alarm viewer : Attributes (1)
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
25/43
Schneider Electric 25- CS&P – OI Graphic Configuration
Columns tab
Column rank [0-9]
• Alarm viewer : Attributes (2)
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
26/43
Schneider Electric 26- CS&P – OI Graphic Configuration
Tool bar tab
If Yes, customizebuttons andseparator rank
[0-15]
Tool bar usage
• Alarm viewer : Attributes (3)
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
27/43
Schneider Electric 27- CS&P – OI Graphic Configuration
Alarm list
Sorted by
Timestamp
Browser
• Alarm viewer : Components (1)
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
28/43
Schneider Electric 28- CS&P – OI Graphic Configuration
Events list
Sorted by
Timestamp
States list
Sorted by
ObjectName
• Alarm viewer : Components (2)
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
29/43
Schneider Electric 29- CS&P – OI Graphic Configuration
General tab
real timearchive
Series
• Trend viewer : Attributes
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
30/43
Schneider Electric 30- CS&P – OI Graphic Configuration
Variable :Current
Relation with MV
X axis
Y axis
• Trend viewer : Components
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
31/43
Schneider Electric 31- CS&P – OI Graphic Configuration
• Content
SCE OI General Parameters
DisplayActive X
Graphical Animation
Users & Rights
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
32/43
Schneider Electric 32- CS&P – OI Graphic Configuration
2 types of symbols :
- shape : basic graphical objects
- multistate : representation of animated objects
Geometrical objects
Text (normal, var text)
Image (gif, jpg)
Memo
Datapoint multistates (SPS, DPS,
MPS, MV, xCT, …)
• Symbols : Shape and multistate (1)
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
33/43
Schneider Electric 33- CS&P – OI Graphic Configuration
DPS Multistate
List of components
Graphical Open state
Relation between electrical and
graphical states
Relation with DPS
• Symbols : Shape and multistate (2)
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
34/43
Schneider Electric 34- CS&P – OI Graphic Configuration
1°) Add a memo
icon in your mimic2°) Add a memo in Graphic partwhere the text will be stored.
3°) Add a relation
with an system orelectric object :
• Memos (1)
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
35/43
Schneider Electric 35- CS&P – OI Graphic Configuration
Note : Memo is filled in PACiS OI
runtime
Relation betweenmemo storage and
graphic object
Memo representationinto SCE Mimic editor
Memo icon attributes
Relation between memo storage andelectric object (CB here)
• Memos (2)
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
36/43
Schneider Electric 36- CS&P – OI Graphic Configuration
Position inside the
upper level object
here Mimic
Position inside theupper level object
here Group
• Groups
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
37/43
Schneider Electric 37- CS&P – OI Graphic Configuration
Add relation
refers to : kind of object
(here MV datapoint)
Text attributes
IT IS THE RELATION WHICHHOLDS THE ATTRIBUTES
!
Text to be displayed
• Variable Text
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
38/43
Schneider Electric 38- CS&P – OI Graphic Configuration
Create a line
Create a rectangle
Create a circle
Create a polyline
Create a text
Create a variable text
Create a memo icon
Create an image
Show/Hide the grid
Zoom +Zoom -
Anti-alliasing effect
Group edition
Exit group edition
Group Selected Graphic Objects
Ungroup Graphic group object
Rotation 90°Flip
Mirror
Graphic Object at Bottom plane
Graphic Object at Backward plane
Graphic Object at Forward plane
Graphic Object at Top plane
Scrolling list of alignment functionsScrolling control
Align Horizontal Top Align Horizontal Center Align Horizontal Bottom Align Horizontal Side by Side Align Vertical Left Align Vertical Center Align Vertical Right Align Vertical Side by Side
Refer to HI
chapter of SCEdocumentation
• Facilities
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
39/43
Schneider Electric 39- CS&P – OI Graphic Configuration
• Content
SCE OI General Parameters
DisplayActive X
Graphical Animation
Users & Rights
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
40/43
Schneider Electric 40- CS&P – OI Graphic Configuration
Rights / Usersunder GraphicPart
Right type :
alarm ack.,command, view
List of 64 rights
Refer to good practicesfor naming rules
• Right List
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
41/43
Schneider Electric 41- CS&P – OI Graphic Configuration
User names
User right bytype
Standard rights
General rights :
exit
hard copyaudible alarm stopSMT administrator
SMT and analysis tools
• User profile list (1)
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
42/43
Schneider Electric 42- CS&P – OI Graphic Configuration
Alarm viewer rights :
print
archive viewing
filtering
sortingsetting saving
field resizing
field removing
Trend viewer rights :
print
panoramic zoom
add pen
start and stop
pen definition
• User profile list (2)
-
8/20/2019 L2 V4 14 GRAPHIC Configuration D 03
43/43
Schneider Electric 43- CS&P – OI Graphic Configuration
Example with command right on a bay1°) Select your bay
2°) Add relation “hasfor command right”
3°) Link it to a right inthe list
4°) Select this rightin the list
5°) Add relation“belongs to”
6°) Link it to a rightcategory in profile list
• Right Configuration