C O N D E N S I N G B O I L E R S
ethos 70, 90, 110 & 130 WALL MOUNTED CONDENSING BOILERS
ethos 350 & 550 FLOOR STANDING CONDENSING BOILERS
I N S P I R E D E F F I C I E N C Y
I N T R O D U C T I O N
C O N T E N T S
Renowned for developing innovative products, Mikrofill has built its success on quality, reliability and outstanding
customer service.
Our rapidly expanding range of products include commercial condensing boilers,
hot water loading systems and pressurisation equipment.
Ethos Condensing Boilers have been developed specifically to meet the demands of modern commercial
buildings. The Ethos range exceeds the most stringent environmental
requirements while optimising efficiency and remaining easy to install.
Models have individual outputs from 70 to 550 kW, featuring premix burners,
stainless steel heat exchangers and integral cascade control. Ethos 70, 90, 110 & 130 4-5
Technical Data 6
Efficiency Data 7
Dimensions 7
Main Components 8-9
Ethos 350 & 550 10-11
Technical Data 12
Efficiency Data 13
Dimensions 13
Main Components 14-15
Installation Schematics 16-17
Ancillaries 18-19
C O N D E N S I N G B O I L E R S
ethos
ethosDesigned and manufactured in the UK, the Ethos wall mounted boiler range offers the following features and benefits.
Advancing on its already proven technology, the Ethos wall mounted boiler range offers individual outputs from 70 - 130kW and multiple outputs up to 780kW.
7 0 , 9 0 , 1 1 0 & 1 3 0
Seasonal efficiency in excess of 96%
Class 5 Nox
Stainless steel heat exchanger with 5 year warranty
F E AT U R E S● 10 : 1 turn down ratio
● Available in 70 – 130kW models
● Stainless steel heat exchanger
● Integral boiler shunt pump
● Onboard cascade control unit
B E N E F I T S● Seasonal efficiency in excess of 96%
● Installation options allowing 7 – 780kW
● 5 year heat exchanger warranty
● Nox levels of 33 mg/kW
● < 48 dba
W A L L M O U N T E D C O N D E N S I N G B O I L E R S
4 5
MODEL ethos 70 ethos 90 ethos 110 ethos 130
DIMENSIONS H X W X D 905 x 530 x 475mm 905 x 530 x 675mm
WEIGHT (EMPTY) 67kg 91kg 102kg 116kg
FLOW / RETURN CONNECTIONS ¾” BSP 1¼” BSP 1¼” BSP 1¼” BSP
GAS CONNECTION ¾” BSP ¾” BSP ¾” BSP ¾” BSP
FLUE CONNECTION 80mm 100mm 100mm 100mm
AIR SUPPLY CONNECTION 80mm 100mm 100mm 100mm
ELECTRICAL SUPPLY 230 VAC 230 VAC 230 VAC 230 VAC
POWER CONSUMPTION 369W 369W 369W 419W
FREQUENCY 50Hz 50Hz 50Hz 50Hz
FUSE PROTECTION 6 Amp 6 Amp 6 Amp 6 Amp
HEATING PERFORMANCE
NOMINAL HEAT OUTPUT AT 80/60˚C 6.8 - 68.4 kW 8.8 - 87.5 kW 10.7 - 106.9 kW 12.8 - 127.7 kW
NOMINAL HEAT OUTPUT AT 50/30˚C 7.7 - 76.8 kW 9.7 - 97.2 kW 11.9 - 118.8 kW 14.0 - 140.4 kW
MAXIMUM GAS CONSUMPTION G20 7.4 m3/hr 9.4 m3/hr 11.5 m3/hr 13.6 m3/hr
MAXIMUM GAS CONSUMPTION G31 2.9 m3/hr 3.7 m3/hr 4.5 m3/hr 5.3 m3/hr
TECHNICAL DATA
FLUE GAS DEW POINT 52 °C 52 °C 52 °C 52 °C
FLUE TEMPERATURE AT 80/60°C (AT AMBIENT TEMPERATURE OF 20°C) 75 °C 75 °C 75 °C 75 °C
FLUE MATERIAL TEMPERATURE CLASS T 120 T 120 T 120 T 120
PERMITTED MAX RESISTANCE OF FLUE 140* Pa 140* Pa 200* Pa 200* Pa
CONDENSATION VALUE 3.0 - 5.5 pH 3.0 - 5.5 pH 3.0 - 5.5 pH 3.0 - 5.5 pH
MAX CH FLOW TEMPERATURE 90˚C 90˚C 90˚C 90˚C
CH WATER PRESSURE (MINIMUM / MAXIMUM) 0.5 - 4.0 bar 0.5 - 6.0 bar 0.5 - 6.0 bar 0.5 - 6.0 bar
MINIMUM / MAXIMUM GAS PRESSURE - G20/G25 17 - 20 mbar 17 - 20 mbar 17 - 20 mbar 17 - 20 mbar
MINIMUM / MAXIMUM GAS PRESSURE - G31 30 - 50 mbar 30 - 50 mbar 30 - 50 mbar 30 - 50 mbar
ENVIRONMENTAL DATA
FLUE GAS CO2 CONTENT G20/G25 8.4 % 8.4 % 8.4 % 8.4 %
FLUE GAS CO2 CONTENT G31 9.5 % 9.5 % 9.5 % 9.5 %
NOX LEVELS 33.0 mg/kW 33.0 mg/kW 33.0 mg/kW 33.0 mg/kW
MAX EFFICIENCY (NETT NON CONDENSING) 97.7 % 97.2 % 97.2 % 98.2 %
MAX EFFICIENCY (NETT CONDENSING) 109.7 % 108 % 108 % 108 %
SEASONAL EFFICIENCY 96.79 % 95.46 % 95.46 % 95.63 %
W A L L M O U N T E D C O N D E N S I N G B O I L E R S
T E C H N I C A L D A T A E F F I C I E N C Y D A T A
D I M E N S I O N S
ethos 7 0 , 9 0 , 1 1 0 & 1 3 0
A 1 2 0 m m 1 4 0 m m 1 4 0 m m 1 4 0 m mB 8 0 m m 1 0 0 m m 1 0 0 m m 1 0 0 m mC 1 2 5 m m 9 5 m m 9 5 m m 9 5 m mD 4 7 5 m m 4 7 5 m m 6 7 5 m m 6 7 5 m mE 6 5 m m 6 5 m m 7 5 m m 7 5 m mF 1 2 5 m m 1 2 5 m m 1 1 5 m m 1 1 5 m mG 3/ 4” 1 1/ 4” 1 1/ 4” 1 1/ 4”H 3/ 4” 3/ 4” 3/ 4” 3/ 4”
ethos 70 ethos 90 ethos 110 ethos 130
NO
X LE
VELS
3
3.0
mg/
kW
NO
X LE
VELS
3
3.0
mg/
kW
NO
X LE
VELS
3
3.0
mg/
kW
NO
X LE
VELS
3
3.0
mg/
kW
NO
MIN
AL
HEA
T O
UTP
UT
AT 5
0/3
0˚C
7
.7 -
76
.8 k
W
NO
MIN
AL
HEA
T O
UTP
UT
AT 5
0/3
0˚C
9
.7 -
97
.2 k
W
NO
MIN
AL
HEA
T O
UTP
UT
AT 5
0/3
0˚C
1
1.9
- 1
18
.8 k
W
NO
MIN
AL
HEA
T O
UTP
UT
AT 5
0/3
0˚C
1
4.0
- 1
40
.4 k
W
NO
MIN
AL
HEA
T O
UTP
UT
AT 8
0/6
0˚C
6
.8 -
68
.4 k
W
NO
MIN
AL
HEA
T O
UTP
UT
AT 8
0/6
0˚C
8
.8 -
87
.5 k
W
NO
MIN
AL
HEA
T O
UTP
UT
AT 8
0/6
0˚C
1
0.7
- 1
06
.9 k
W
NO
MIN
AL
HEA
T O
UTP
UT
AT 8
0/6
0˚C
1
2.8
- 1
27
.7 k
W
SEA
SON
AL
EFFI
CIE
NC
Y 9
6.7
9 %
SEA
SON
AL
EFFI
CIE
NC
Y 9
5.4
6 %
SEA
SON
AL
EFFI
CIE
NC
Y 9
5.4
6 %
SEA
SON
AL
EFFI
CIE
NC
Y 9
5.6
3 %
905
530
110 70
180
65
245 Ø
55
70
A B
C
D
E F
G GH
* With this resistance value the heat output will remain within the specifications indicated on the dataplate; if the resistance is higher,the heat output will be reduced.
6 7
W A L L M O U N T E D C O N D E N S I N G B O I L E R S
M A I N C O M P O N E N T S
E T H O S 7 0 E T H O S 9 0 , 1 1 0 A N D 1 3 0
ethos 7 0 , 9 0 , 1 1 0 & 1 3 0
01070107
13
13
02
08
08
0904
04
1010
09
12 05
11 11
12
06
02
03
06
05
15 1714 16 18
Bottom Connections
1 Air Inlet Connection
2 Air Inlet Tube
3 Air Vent Valve*
4 Combustion Fan
5 Controls Housing
6 Flue Gas Temperature Sensor
7 Flue Outlet Connection
8 Gas Valve and Venturi
9 Grundfos UPML 25-105 130 PWM
10 Heat Exchanger and Burner Package
11 Ignition Transformer
12 Pressure Relief Valve
13 Sealed Air Inlet Trap
14 Flow Connection
15 Condense Syphon
16 Gas Connection
17 Condense Outlet
18 Return Connection
* Only present on Ethos 90, 110 and 130 Model Heat Exchangers.
B O T T O M C O N N E C T I O N S
8 9
Drawing on the success of the Ethos wall mounted condensing boilers, Mikrofill introduce the Ethos 350 and 550.
F L O O R S T A N D I N G C O N D E N S I N G B O I L E R S
ethos 3 5 0 & 5 5 0
D UA LT E C H S Y S T E M
Introducing the Dualtech System,
a breakthrough in commercial
boiler design.
Dualtech features two independent
premix burners to each
condensing boiler. This system
immediately doubles the load
matching capability of each boiler
thus enabling an unsurpassed
modulation of 20:1.
A single boiler incorporating a
two thirds standby of a buildings
demand clearly decreases capital
cost aswell as installation time.
Designed and manufactured in the UK, the Ethos floor standing boiler range offers the following features and benefits.
F E AT U R E S● Available in 350 and 550kW models
● 20 : 1 turn down ratio
● 2 premix burners per boiler
● Stainless steel heat exchanger
● Onboard cascade control unit
B E N E F I T S● Nox levels of 31 mg/kW
● Seasonal efficiency in excess of 95%
● Installation options allowing 17.5 – 4.4mW
● 5 year heat exchanger warranty
● < 75 dba
10 11
MODEL ethos 350 ethos 550
DIMENSIONS (H X W X D) [1] 1300 x 750 x 1100mm 1300 x 750 x 1500mm
WATER CONTENT OF APPLIANCE 25 Litre 30 Litre
WEIGHT (EMPTY) 234kg 370kg
FLOW / RETURN CONNECTIONS DN50 PN16 Flange DN65 PN16 Flange
GAS CONNECTION 1¼” BSP 1½” BSP
FLUE CONNECTION 150mm 180mm
ELECTRICAL SUPPLY 230V 230V
POWER CONSUMPTION 558W 898W
FREQUENCY 50Hz 50Hz
FUSE PROTECTION 10 Amp 10 Amp
HEATING PERFORMANCE
NOMINAL HEAT INPUT (NETT) 17.5 - 350 kW 27.5 - 550 kW
NOMINAL HEAT OUTPUT AT 80/60˚C 17.2 - 343 kW 27.0 - 539 kW
NOMINAL HEAT OUTPUT AT 50/30˚C 18.9 - 378 kW 29.7 - 594 kW
MAXIMUM GAS CONSUMPTION G20 35.5 m3/hr 56.1 m3/hr
MAXIMUM GAS CONSUMPTION G31 13.6 m3/hr 20.9 m3/hr
TECHNICAL DATA
FLUE GAS DEW POINT 52 °C 52 °C
FLUE TEMPERATURE AT 80/60°C (AT AMBIENT TEMPERATURE OF 20°C) 75 °C 75 °C
FLUE MATERIAL TEMPERATURE CLASS T 120 T 120
PERMITTED MAX RESISTANCE OF FLUE SYSTEM [2] 200 Pa 250 Pa
CONDENSATION VALUE 3.0 - 5.5 pH 3.0 - 5.5 pH
MAX CH FLOW TEMPERATURE 90˚C 90˚C
CH WATER PRESSURE (MINIMUM / MAXIMUM) 0.5 - 6 bar 0.5 - 6 bar
MINIMUM / MAXIMUM GAS PRESSURE - G20/G25 17 - 20 mbar 17 - 20 mbar
MINIMUM / MAXIMUM GAS PRESSURE - G31 30 - 50 mbar 30 - 50 mbar
ENVIRONMENTAL DATA
NOX LEVELS 31mg/kW 31mg/kW
MAX EFFICIENCY (NETT NON CONDENSING) 98 % 98 %
MAX EFFICIENCY (NETT CONDENSING) 108 % 108 %
SEASONAL EFFICIENCY 95.6 % 95.6 %
F L O O R S T A N D I N G C O N D E N S I N G B O I L E R S
T E C H N I C A L D A T A E F F I C I E N C Y D A T A
D I M E N S I O N S
ethos 3 5 0 & 5 5 0
A 1 ” 1 ”B ø 3 2 m m ø 3 2 m mC 1 1/ 4” 1 1/ 2”D 2 ” 2 1/ 2”E ø 1 5 0 m m ø 1 8 0 m mF 1 1 0 0 m m 1 5 0 0 m m
ethos 350 ethos 550
130
0
750
E
D
D
A
B
375
100
175
115
665
100
0
420
725
855
175
405
C
F
NO
X LE
VELS
3
1 m
g/kW
NO
X LE
VELS
3
1 m
g/kW
NO
MIN
AL
HEA
T O
UTP
UT
AT 5
0/3
0˚C
1
8.9
- 3
78
.0 k
W
NO
MIN
AL
HEA
T O
UTP
UT
AT 5
0/3
0˚C
2
9.7
- 5
94
.0 k
W
NO
MIN
AL
HEA
T O
UTP
UT
AT 8
0/6
0˚C
1
7.2
- 3
43
.0 k
W
NO
MIN
AL
HEA
T O
UTP
UT
AT 8
0/6
0˚C
2
7.0
- 5
39
.0 k
W
SEA
SON
AL
EFFI
CIE
NC
Y 9
5.6
%
SEA
SON
AL
EFFI
CIE
NC
Y 9
5.6
%
[1] Depth dimensions are taken from the front to the rear of the casing and do not include the external pipework.Height dimensions are taken from the bottom of the boiler and do not include the height of the supplied adjustable feet.
[2] With this resistance value the heat output will remain within the specifications indicated on the dataplate; if the resistance is higher,the heat output will be reduced.
12 13
F L O O R S T A N D I N G C O N D E N S I N G B O I L E R S
M A I N C O M P O N E N T S
ethos 3 5 0 & 5 5 0
13
11
12
14
10
09
08
03
07
08
04
06
0603
09
01
05
021 2
5
6
4
8
8
3
13
11
12
14
10
3
7
9
6
9
1 Burner #01 Control Unit
2 Burner #02 Control Unit
3 Combustion Fan
4 Control Fascia
5 Electrical Connections
6 Gas Valve
7 Heat Exchanger and Burner Package
8 Flap Valve
9 Venturi
10 Condense Outlet
11 Flow Connection
12 Gas Connection
13 Pressure Relief Valve Outlet
14 Return ConnectionF R O N T V I E W
T O P V I E W
R E A R V I E W
R E A R C O N N E C T I O N S
14 15
F L O O R S T A N D I N G C O N D E N S I N G B O I L E R S
ethos 3 5 0 & 5 5 0 W A L L M O U N T E D C O N D E N S I N G B O I L E R S
ethos 7 0 , 9 0 , 1 1 0 & 1 3 0
IVIV IV
CondenseWaste
MIKROFILL
ExpansionVessel
LSV DOC
AAV
Heating Circuit
Mains ColdWater Supply
DOC
IV
ServiceValve
ETHOS Boiler
ETHOSBoiler
MIK
ROVE
NT
IVIVIV
CondenseWaste
MIKROFILL
ExpansionVessel
LSV DOC
AAV
Heating Circuit
Mains ColdWater Supply
DOC
IV
ServiceValve
ETHOS FloorStanding Boiler
ETHOS FloorStanding Boiler
MIK
ROVE
NT
IVIV IV
CondenseWaste
MIKROFILL
ExpansionVessel
LSV DOC
AAV
Heating Circuit
Mains ColdWater Supply
DOC
IV
ServiceValve
ETHOS Boiler
ETHOSBoiler
MIK
ROVE
NT
IVIV IV IV
ETHOS Boiler
ETHOSBoiler
IVIVIV
MIKROFILL
ExpansionVessel
LSV DOC
AAV
Heating Circuit
Mains ColdWater Supply
DOC
IV
ServiceValve
ETHOS FloorStanding Boiler
ETHOS FloorStanding Boiler
MIK
ROVEN
T
IVIVIV
CondenseWaste
MIKROFILL
IV
ETHOS FloorStanding Boiler
ETHOS FloorStanding Boiler
Schematic drawings of an Ethos wall mounted boiler installation, including a Mikrofill pressurisation package and an Extreme domestic hot water loading cylinder.
Schematic drawings of an Ethos floor standing boiler installation, including a Mikrofill pressurisation package and an Extreme domestic hot water loading cylinder.
16 17
L O W L O S S H E A D E R / A I R D I R T S E P E R A T O R
ethosAs water impinges on the spiral wound brushes a low pressure area is created behind each filament of the brush, this forces any dissolved gases to be released.
The use of two removable stainless steel brushes ensures that any dissolved gases within the system are removed by the lower brush, whilst gases entrained in the boiler header system are released by the upper brush. These gases then rise to the top of the unit and are expelled by the automatic air vent.
The Mikrovent headers are available to suit connected loads of 150, 250, 400, 750 and 1000kW.
All in all the Mikrovent is a worthwhile addition to any new or refurbished commercial heating or chilled water system.
E T H O S 7 0 – 1 3 0 K W F L U E A P P L I C A T I O N S
The Ethos wall mounted boiler range is approved for use with both “open flued” and “room sealed” type flue systems and as such are suitable for most applications. Flue components are readily available, including standard horizontal and vertical kits.
By using either concentric or the 2 pipe system different flue lengths can be achieved. Care should be taken when siting the flue outlet as all condensing boilers produce water vapour in the form of “pluming” which can be a nuisance.
There is a maximum over pressure of around 1.4 mbar (140 Pa) for the Ethos 70, 90 and 2.0 mbar (200 Pa) for the Ethos 110, 130 in the boiler for the flue gas discharge system.
For further details on the flueing capabilities of the Ethos 70 – 130 models please contact the sales team on 03452 60 60 20 or download the O & M manual at www.mikrofill.com
Mikrovent headers incorporate an air and dirt seperator capable of filtration of sediment from 5 microns and larger
Header Type Dia mm A B C D E F G H I
BSP THREAD PN16 FLANGE
T1 T2 T3 T4 Boiler System
Mikrovent 150 80 900 240 470 275 340 370 450 210 170 ½” M
½” F
¾” F
½”F DN 50 DN 50
Mikrovent 250 100 1600 320 760 400 545 760 1080 265 225 ½” M
½” F
¾” F
½” F DN 50 DN 50
Mikrovent 400 125 1600 320 760 400 545 760 1080 285 245 ½” M
½” F
¾” F
½”F DN 65 DN 65
Mikrovent 750 150 1700 320 835 450 565 835 1155 310 270 ½” M
½” F
¾” F
½” F DN 80 DN 100
Mikrovent 1000 200 1700 320 835 450 565 835 1155 350 310 ½” M
½” F
¾” F
½”F DN 80 DN 125
T H E M I K R O V E N T
M I K R O V E N T H E A D E R D I M E N S I O N S
T1
T2
T3
185
BOILERFLOW
SYSTEMFLOW
BOILERRETURN
SYSTEMRETURN
T4
15
ALL DIMENSIONS ARE IN MILLIMETRESUNLESS OTHERWISE SPECIFIED.
A
B
C
D
F
E
H
HI H
I
G
18 19
Mikrofill Systems Ltd. West Court, Merse Road, North Moons Moat, Redditch, Worcestershire B98 9HL, UK
T +44 (0)3452 60 60 20 F +44 (0)3452 60 60 21 E [email protected] www.mikrofill.com