Advantages of KAFH OT hot air heaters

• Reduction of CO2 emissions and humidity in the atmosphere, allowing for a better quality of life for birds.• Increased of available space and easier cleaning tasks after breeding.• High quality, durability and comfortable heat.• As it is installed on the outside, no additional gas evacuation system is required.• It can be managed by existing climate controls or computers in poultry buildings (On / Off or 0-10 Vdc) and Stand Alone operation• For electrical maintenance tasks, going inside the building is not required.• Quickly heat up.• Up to 25% savings in energy consumption

Characteristics KAFH OT

KAFH OT closed combustion system hot air heaters are devices for heat generation addressed to livestock applications. They run on LPG or NG.

Closed combustion heating system means no CO2 and no watervapor in the house, allowing better environmental conditions during the cycle and reducing ventilation needs.

Capacity 72 kW.

Installation and operation

KAFH OT closed combustion hot air heaters are installed outside the buildings, the hot air diffuser and impeller fan remain inside the building.

When heat is required, the burner is automatically switched on through the ignition electrode. After reaching the right temperature on the closed combustion chamber, the fan will start making the air room to circulate through the heat exchanger increasing its temperature.

By moving the diffuser the hot air is addressed to where it is needed.Combustion takes place outside the building.

When the set temperature is reached, the burner is turned off and the fan remains on until the temperature falls below the impeller temperature.

Indirect gas fired heater KAFH OT - Outdoor installationOptimal combination of quality environmental, efficiency and space availability

Ed

.04.

2018

GB

Technical features KAFH OT

Calorífic capacity output (kW) 72

Useful capacity (kW) 70

Efficiency (%) 95

Fan (mm) 630

Rotation speed (rpm) 1.400

Air flow at 15ºC (m3/h) 6.800

Gas flow at 15º CLPG(kg/h) 5,8

NG (m3/h) 7,8

Working pressure

(mbar)

LPG 37

NG 20

Supply voltage 230Vac / 50-60Hz-IP54

Electric power 760 W / 3,4 A

Weight (kg) 290

Dimensions KAFH OT

A (mm) 1.155

B (mm) 1.655

C (mm) 1.043

Ø Exhausted pipe (mm) 80/125

Gas (“) 3/4

Fan with protection

grid Adjustable diffuser plates helpsto address air-flow

direction

Aluminized steel heat exchanger