HC- series - Industrial Cooling Systems & Coolers...coolers • Best heat transfer results per given...
Transcript of HC- series - Industrial Cooling Systems & Coolers...coolers • Best heat transfer results per given...
© A
KG
200
9 (c
hang
es a
nd e
rror
s ex
pect
ed)
ClassicHC- series
HC- seriesClassic
Specifications:Maximum Working Pressure 250 PSI
Maximum Working Temperature 250°F
MaterialsCooler Aluminum
Shroud Power Painted Steel
Fan Guard Zinc Plaited Steel
Fan Blade Polypropylene Blades Aluminum Hub
Mounting Brackets Powder Painted Steel
HC32
HC48
HC66
HC120
HC180HC240
HC300
HC380
HC14 @ 1750 RPM
HC26 @ 1750 RPM
5
10
20
40
80
160
320
640
5 10 20 40 80 160 320
HEA
T R
EJEC
TIO
N H
orse
pow
er R
emov
ed @
100
-F
ETD
OIL FLOW - GPM
HC32
HC48
HC66
HC120
HC180HC240
HC300
HC380
HC14 @ 3450 RPM
HC26 @ 3450 RPM
5
10
20
40
80
160
320
640
5 10 20 40 80 160 320
HEA
T R
EJEC
TIO
N H
orse
pow
er R
emov
ed @
100
-F
ETD
OIL FLOW - GPM
pERFORMANCE HC @ 1750 RpM FAN SpEED
pERFORMANCE HC @ 1140 RpM FAN SpEED
HC- seriesClassic
MODEL NUMBER A B C
(Approx.) D E F G (SAE) H J K L M P
HC14 12.48 16.02 11.1 11.3 3.3 0.55 #16 SAE 1 5/16-12 UN-2B 14.33 3.07 3.5 7.36 M8 x 10 #8 SAE
3/4-16 UN-2B
HC26 16.14 19.96 11.1 14.96 3.31 0.59 #16 SAE 1 5/16-12 UN-2B 18.46 3.07 3.5 7.36 M8 x 10 #8 SAE
3/4-16 UN-2B
HC32 16.14 20.67 12.59 14.92 6.02 0.59 #20 SAE 1 5/8-12 UN-2B 19.45 4.17 3.74 9.02 M10 x 20 #8 SAE
3/4-16 UN-2B
HC48 20.47 26.65 12.44 19.21 6.02 0.59 #20 SAE 1 5/8-12 UN-2B 25.16 4.17 3.74 9.02 M10 x 20 #12 SAE
1 1/16-12 UN-2B
HC66 22.32 30.59 12.44 21.06 6.02 0.59 #20 SAE 1 5/8-12 UN-2B 29.09 4.17 3.74 9.02 M10 x 20 #12 SAE
1 1/16-12 UN-2B
HC120 28.15 39.45 15.27 20.12 10.2 2.12 2" SAE 4 BOLT FLG 37.64 5.39 7.87 15.47 M12 x 20 #12 SAE
1 1/16-12 UN-2B
HC180 37.24 43.39 17.32 29.45 9.09 0.59 2" SAE 4 BOLT FLG 42.76 5.39 7.87 15.47 M12 x 20 #12 SAE
1 1/16-12 UN-2B
HC240 38.94 45.33 18.82 32.38 9.02 0.59 2" SAE 4 BOLT FLG 43.52 5.39 7.87 15.47 M12 x 20 #12 SAE
1 1/16-12 UN-2B
HC300 45.33 51.24 20.94 34.49 11.02 0.65 3" SAE 4 BOLT FLG 49.44 5.39 7.87 15.47 M12 x 20 #16 SAE
1 5/16-12 UN-2B
HC380 59.76 53.27 20.94 43.62 17.56 2.00 3" SAE 4 BOLT FLG 50.35 7.8 10.00 20.00 .75 x 2.25 #16 SAE
1 5/16-12 UN-2B
MODEL NUMBER
Motor Size (cubic in.)
Operating Speed (RpM)
Motor Flow Rate @
Operating Speed (gpm)
Motor pressure @ Operating
Speed (psi)
Motor Max pressure (psi)
Approx Noise Level (dB(A), 1 m)
Working Pressure
(psi)
Approx. Shipping
Weight (lbs)
HC14 .218 3450/1725 3.6/1.8 500 2000 80/65 250 45
HC26.218 3450/1725 3.6/1.8 500 2000 85/73 250 65
.372 3450/1725 6.2/3.1 500 2000 85/73 250 65
HC32.218 1750/1140 1.8/1.2 500 2000 85/73 250 75
.372 1750/1140 3.1/2.1 1050/500 2000 85/73 250 75
HC48.218 1750/1140 1.8/1.2 500 2000 85/75 250 175
.372 1750/1140 3.1/2.1 1050/500 2000 85/75 250 175
HC66.372 1750/1140 3.1/2.1 1050/500 2000 88/79 250 208
.5 1750/1140 4.2/2.7 1440/560 3500 88/79 250 208
HC120.5 1750/1140 4.2/2.7 1440/560 3500 93/83 250 300
1.4 1750/1140 11.8/7.7 520/500 2750 93/83 250 300
HC180.5 1750/1140 4.2/2.7 1440/560 3500 94/86 250 405
1.4 1750/1140 11.8/7.7 520/500 2750 94/86 250 405
HC2401.4 1750/1140 11.8/7.7 1010/525 2750 96/88 250 445
1.95 1750/1140 16.4/10.7 725/500 3500 96/88 250 445
HC3001.4 1750/1140 11.8/7.7 1630/765 2750 98/89 250 618
1.95 1750/1140 16.4/10.7 1170/550 3500 98/89 250 618
HC3801.4 1750/1140 11.8/7.7 1600/735 2750 101/92 250 875
1.95 1750/1140 16.4/10.7 1150/530 3500 101/92 250 875
HC SERIES TECHNICAL DATA
DIMENSIONS
HC- seriesClassic
ORDERING INFORMATION
HC SERIES MODEL SIZESELECTED
MOTOR CODE0 = NO MOTOR0218 = 0.218 CU-IN0372 = 0.372 CU-IN0050 = 0.50 CU-IN0120 = 1.2 CU-IN0140 = 1.4 CU-IN0195 = 1.95 CU-IN
CUSTOM FEATURE CODER = REVERSED AIR FLOWAD = SAE TO NPT ADAPTORSH = HERESITE COATING COREF = FOAM FILTER
BYPASS DATABPNV = BYPASS NO VALVEBP25 = 25PSI INTERNAL BYPASS BP30 = 30PSI INTERNAL BYPASSBP60 = 60PSI INTERNAL BYPASSBP65 = 65PSI INTERNAL BYPASS
SELECTION PROCEDURE
DIMENSIONS
The performance curves above are based on the following : •50SUSOil. •100°F Entering Temperature Difference (ETD)
If your application conditions are difference, use the following selection procedure:
STEp 1. Determine the Heat LoadIn most cases you can use 1/3 of the input horsepower.Example: 30 HP Power Unit = 10 HP Heat Load
STEp 2. Determine the Actual ETD Desired Entering OIL Temperature — Entering AIR Temperature = ETDThe Entering oil temperature is the highest desired oil temperature. The entering air temperature is the highest anticipated ambient air temperature, plus any pre-heating of the air prior to it entering the cooler.
STEp 3. Calculate the Adjusted Hp for Selection
STEp 4. Determine The Model From The CurvesRead up from the GPM to the required heat rejection. Select any model on, or above this point.
Horse power
Heat Load
100
Desired ETDHorsepower For UseWith Selection Chart
=x
A
F
D
B
E
H
ROTATION
Global Artwork HC Series
Outlet PortP
Inlet PortPG SAE
Fitting Typ 2
C
JKL
M
AIR FLOW
APPROX.[2.00"]
51
[1.69"]43
[3.06]78
2" SAE4-BOLT FLANGE
3" SAE4-BOLT FLANGE
[3.00"]76
[2.44]62
[4.19]106
HC- seriesClassicDIRTY ENVIRONMENT COOLING SYSTEMS
• HC dirty environment series low fouling coolers withnonlouveredfindesignprovidesthebestHEAT TRANSFER per given cooler size in the industry.
• HC coolers have proprietary R & D designed, engineeredandtestedinternalandexternalfinsunique to AKG THERMAL SYSTEMS coolers.
• All HC series coolers are available with internal pressure BYPASS option.
• HC rugged series coolers offer the largest, most comprehensive cooler size ranges with competitive pricing and deliveries from stock.
FEATURES OF THE HC SERIES:• Thecoolersareequippedwithanti-cloggingfins• High-Performance cooling assemblies• Hydraulic motor powered fan • The heat is transferred from the medium to be cooled to the
ambient air• Cooler can be universally used in hydraulic oil, transmission oil,
engine oil, lubricating oil and coolant circuits• For the cooling of mineral oil, synthetic oil, biological oil as well
as of HFA, HFB, HFC and HFD liquids and water with at least 50 per cent of antifreeze and anti corrosive additives (other media available).
• Can be exposed to operating pressures of up to 17 bar.
BENEFITS:• Especially suited for dirty environments. Fin system prevents
clogging and is easy to clean• Highlyflexiblecomplete,ready-to-usecoolingpackages• Compactandrobustdesign,field-testedduringmanyyearsof
use in rugged real life conditions• Largest and most comprehensive series of mobile hydraulic
coolers• Best heat transfer results per given coolers size due to
comprehensive research and development • Highest quality due to professional engineering and in-house
manufacturing • Available from stock or at short notice• As a standard, equipped with AKG’s patented double-life
hollow sections designed to increase cooler service life
PRODUCT INFORMATIONAKG Classic Series is a standard line of products from the market leader in high performance aluminum cooling systems. AKG is best known for its world-wide presence, German engineering and extremely reliable product quality on the one hand and very competitive prices on the other hand.
The Classic series consists of different models for mobile and stationary applications and are available through our global dealer network. This line of products embraces complete cooling systems that comply with both European and American standards, is suited for normal or rugged environmental operating conditions, and is powered by AC-, DC or hydraulic-motor-driven fans and is also available with noise-optimized models.
All of AKG’s solutions have been developed with state-of-the-art technology, produced in compliance with the highest quality standards and are comprehensively tested in the company’s own research and test facility.
HC SERIES FEATURES/BENEFITS
PATENTED FLEXIBLE AKG HOLLOW PROFILEClassic Series uses patentedAKGprofilesto reduce local peak strains. This way, the strength of heat exchanges is significantlyincreasedand their service life time considerably prolonged.
AKG HOLLOW pROFILE FEATURES:
Reduced Strain: Strength calculations show that when using AKG hollow profilesmaximumstrainisreducedbyafactorof2
prolonged Service Life Time: Extensive rig tests have shown that service life time increases by a factor ranging from 3 to 5
with standard profile with hollow profile
© A
KG
201
0 (c
hang
es a
nd e
rror
s ex
pect
ed)
AKG is a globally leading supplier of high-performance coolers and heat exchangers as well as customised system solutions, that comply with the highest quality standards.
On a world-wide scale, 2,400 employees work at 14 manufacturing facilities located in Germany, France, United Kingdom, Latvia, the U.S.A., China and India. Together with a number of additional oversea sales companies they are on duty around the clock.
The longstanding and competent partnership with global OEM customers from 22 lines of business
such as construction machinery, compressed-air systems, agricultural and forestry machines, vehicle constructionandmanyotherfieldsofapplication give fresh and innovative impetus to the mobile and industrial standard type series.
AKG operates one of the world’s largest research, development, measurement and validation centres for cooling solutions and customised applications.
For 98 years AKG’s heat exchangers have stood for innovative solutions as well as highest engineering and manufacturing competence.
AKG – A STRONG GLOBALLY INTEGRATED GROUP OF COMPANIES
Aluminum Coolers – Made by AKG
DIN EN ISO 9001
AKG Thermal Systems, Inc.809 Mattress factory RoadP.O. Box 189Mebane, NC 27302-0189USA
Tel: +1 919-563-48-71Fax: +1 919-563-49-17E-Mail: [email protected]: www.akgts.com