GRUNDFOS PRODUCT GUIDE - User Manual Search Engine › Pump › 181833Grundfos...water from the well...
Transcript of GRUNDFOS PRODUCT GUIDE - User Manual Search Engine › Pump › 181833Grundfos...water from the well...
-
GRUNDFOS PRODUCT GUIDE
Domestic Water Supply Family
DWS Product Guide 8-09.indd 1 8/18/2009 2:32:25 PM
-
Domestic Water Supply Family Table of Contents
Applications Page No.
• Constantpressure............................................................ 5
• Flowbasedpressureboosting...................................... 5
• Suctionlift...........................................................................6
• Rainwaterharvesting......................................................6
Pump Selections • EZBoost..............................................................................6
• MQ.........................................................................................6
• BasicLineJets....................................................................6
Accessories
• PressureTanks.................................................................... 7
• PressureSwitches.............................................................. 7
• Valves................................................................................... 7
– Check......................................................................... 7
– Foot............................................................................ 7
– Shut-off...................................................................... 7
– FlowControl............................................................. 7
– PressureReducing................................................... 7
– PressureRelief.......................................................... 7
Theory
Matchingconsumptionandpumpcapacity................... 7
Pumpselection....................................................................... 7
Piping......................................................................................... 7
Trouble Shooting Suctionlift................................................................................8
Floodedsuction.......................................................................8
PressureTanks........................................................................9
WebCAPS..................................................................................9
EZBoost................................................................................... 12 MQ...........................................................................................28
BasicLineJets........................................................................38
Submittal Data Sheet.................................................. 57
Handbook
Product Guides
2
DWS Product Guide 8-09.indd 2 8/18/2009 2:32:25 PM
-
Domestic Water Supply Handbook
Handbook Domestic Water Supply Handbook
DWS Product Guide 8-09.indd 3 8/18/2009 2:32:29 PM
-
Handbook Notes
4
DWS Product Guide 8-09.indd 4 8/18/2009 2:32:29 PM
-
Handbook Applications
Constant Pressure System:
Inconstantwaterpressuresystems,onlytherequireddischargepressureneedssetting.Cut-in/outpressuresdonotplayaroleinthissystem.
InGrundfos’sBMQEconstantwaterpressuresystem(EZBoost),thisisdonebyasimpletouchofabuttonontheaccompanyingCU301controlunit.Dischargepressurecanbesetfrom40to100PSI,accordingtoindividualneedsandpipingsystemlimitations.
H
Time
noitpmusnoc ot pihsnoitaler ni yrav ton seod erusserP
Flow Based Pressure Boosting:
Thepumpstartsautomaticallywhenwaterisconsumedandstopsautomaticallywhentheconsumptionceases.Thisisaccomplishedbyaflowswitchconnectedtoaprintedcircuitboard(PCB).TheflowswitchisclosedwhenwaterisconsumedandthesignalsenttothePCBstartsthepump.Theflowswitchisopenedwhenthecon-sumptionceasesandthesignalsenttothePCBstopsthepump.
Thepumpwillproducepressureinrelationtotheflowratewithanyincomingpressurecumulativetothetotaldischargepressure.
Incoming PSI = City Water Pressure Outgoing PSI = Incoming PSI + MQ Performance
5
DWS Product Guide 8-09.indd 5 8/18/2009 2:32:30 PM
-
Suction Lift:Highpressurewaterfromthedrivepipepassesthroughtheventuriandpullswaterfromthewellintotheejector,andthenpushesituptothepump.Thisallowsustopushwateruptothepumpfromdepthsgreaterthan25feet,ortoboosttheoutputfromashallowwellpumptohigherpressures.
Handbook Applications
DRIVEPIPE
SUCTIONPIPE
VENTURI
NOZZLE
INLET
Rain Water Harvesting:Reduce,reuse,andrecycle.TheThreeR’sofconservation.Rainwaterharvestingisthewaytostorerainwaterforfutureusesuchasthewateringofagarden.Simplycollectrainwaterfromtheroofofyourhomethroughtheevesintoastoragecontainer.UsetheMQtopullasuctionlift,usinganoncollapsiblesuctionline,fromthestoragecontainertowateryourgarden.
Pump Selections:
EZ Boost: Constant Pressure at the touch of a button.
TheEZBoostusesthetimetestedtechnologyusedintheSQEconstantpressuresystem(submersibleapplication).TheMSE3motorsarebasedonsolidstateelectronicsandpermanentmagnetrotorswhichaccountforhighmotorefficiencies.VariablespeedisofferedthoughfrequencycontrolviatheCU301remotestatusbox.TheSystemcanbesettooperateatanydutypointintherangebetweenminimumandmaximumperformanceofthepump.TheEZBoosthasbuiltinsafetiesinthesolidstateelectronics.Thesmallfootprintofthepumpallowsthesystemtobepositionedeitherverticallyorhorizon-tallydependingontheneedsoftheapplication.RefertotheEZBoostinstallationvideoonourwebsitewww.grundfos.us
MQ: Maximum Quality Flow Based Pressure Boosting System:
TheMQisacomplete,all-in-oneunit,incorporatingpump,motor,diaphragmtank,pressureandflowsensor,controllerandcheckvalve.Builtinsafetiesensurelonglifeofthepump.Thesesafetiesinclude:dryrunning;excessivetemperature;anyoverloadconditions.TheMQisaselfprimingpumpandneedsnoprimingotherthanthatatinstallation.TheMQisaplug-n-playsystem.
Basic Line: Durable and dependable Basic Line Jets.
Grundfosoffersshallowwell,deepwell,andconvertiblejetpumps.Ourjetsareself-primingcentrifugalpumpssuitablefordomesticwatersupply,lightagriculture,andindustrialwatertransferapplications.Threemodelsinclude:JPS;JPF;JDF.TheJPSareshallowwelljetswithbuilt-inejectors.TheJPFareconvertiblejetswithdetachableejectorassemblyfordeepwellapplications.TheJDFaredeepwelljetswithseparatedeepwellportforconnectiontoDeepWellejectorkits.
6
DWS Product Guide 8-09.indd 6 8/18/2009 2:32:30 PM
-
Handbook Accessories
Pressure Tanks:TanksareprovidedwiththeEZBoostandMQsystems.TheEZBoosthasanexternaltankandtheMQaninternaltank.TheBasicLinehowevermayneedatankdependingonyourapplication.Inordertominimizethenumberofpumpstartsandstopsinthewatersupplysystem,andtoreduceproblemswithwaterhammerinthepipework,apressuretankshouldbeinstalled.
Pressure Switches:Pressureswitchesareusedtocontrolpumpoperation.Theseswitcheshaveacut-inpressureandacut-outpressuretoturnthepumponandoffrespectfully.TheEZBoostcomeswithapressuretransducerforconstantpressure.TheMQhasabuilt-inpressureswitch.BasicLineJetshavethepressureswitchattached.
Valves: Check valves: TheEZBoostandMQsystemshavebuilt-incheckvalves.WhendoingasuctionliftwiththeMQacheck valveisrequiredattheinlet.ThischeckvalveisprovidedwitheveryMQ. Foot Valves:Whenpullingasuctionlift(shallowordeepwell)withtheBasicLineafootvalveisrequired.Thisvalve isinstalledattheendofthesuctionpipetopreventbackflow.TheMQwillalsobenefitfromtheuseofafootvalve whendoingsuctionlifts.
Shut off valves:Useshutoffvalvesinthepipingsysteminsuchawaytomakeitpossibletodrainonlythepartofthe systemthatneedsattentionorrepair. Flow control valves:Usedinapplicationswhereasetamountofflow(gallonsperminute)arerequired.Anexample ofthiswouldbeashowerheadoranirrigationsystem. Pressure reducing valves:Usedinapplicationswheretheincomingwaterpressureexceedsthemaximuminletpres- sureofthepumpasisthecasewiththeMQandcitywaterpressure.ThePressureReducingValveorPRVisusedinline afterthecitywatertapandbeforethepumptoensureasetpressure. Pressure relief valves: Thisvalveisaspringcontrolleddevisethatcanbeadjustedtomeettheneedsofthepumping system.Usedinapplicationswherehighpressurecanresultindamagetoaccessoriessuchastankswherethereare maximumpressureratings.
Theory: Matching consumption and pump capacity: Selectingtherightpumpisamatterofmatchingwaterconsumptionwithpumpcapacity.Installinganunderor oversizedpumpshouldbeavoided.Consumptionvariesgreatlydependingonhousingstandardsandlifestyle.Garden wateringinthesummercanincreaseconsumption.
Pump Selection: Pumpselectionisbasedonthewaterdemandandthesystemhead.Thewaterdemanddependsonthenumberof consumersconnectedtothesystem.HeadcaneitherbeexpressedinfeetorPSI.Headreferstostatichead,pressure head,andfrictionhead.ForassistanceinPumpSelectionrefertotheWebCAPSselectionprogramfoundonthe Grundfoswebsite.
Piping: Inanywatersupplysystem,thesizingandchoiceofmaterialsofthepipeworkhasanimpactonthechoiceofpumps andonthecost.PipingtakesintoaccountthesystemheadasreferredtoinPumpSelection.Staticheadisthedistance fromthegroundwaterleveltotheuppermosttap.Pressureheadisthesystempressurethecustomerwantstoachieve. Inmostresidentialapplicationthispressureisapproximately60PSI.Frictionheaddependsonthepipesize,typeand length.Whencalculatingfrictionlossalwaysremembertoallowfordeteriorationinthepipingschematicasallwater pipeswilleventuallybecomecoatedwithrust,limedeposits,etc.Flowvelocityinthepipingmustbekeptlowasnoise canoccurduetoturbulenceinelbowsandvalvesorfromwaterhammer.Fittingapressurereliefvalveinthedischarge pipingisrecommendedtoprotectthepipingfromover-pressureduetosystemmalfunction.
7
DWS Product Guide 8-09.indd 7 1/8/2010 11:00:13 AM
-
Handbook Troubleshooting
Troubleshooting: Suction Lift: Wheninstallingabovegroundsuctionliftpumps,thefollowingbasicrulesmustbeadheredto: •Avoidfrost. •Pumponlycleanwater. •Installafilterifwatercontainsimpurities. •Afoot-valvemustbeinstalled. •Thesuctionpipemustbe100%airtight. •Thepumpmustbeprimedbeforestartingforthefirsttime.
Fault Cause Remedy
1. The pump is running but there is no pressure.
a) The pump and suction pipework need to be primed.
Fill the pump and pipe with water.
b) The suction pipe is not 100% tight.Check all connections and the suction pipe. Replace ifnecessary.
2. The pump does not stop.a) The pressure switch is set incor-rectly.
Check the settingand adjust accordingly
3. The pump does not deliver enough water.
a) Lack of water in the well. Drill new well.
b) Suction pipe is not 100% tight.Check all connections and the suction pipe. Replace ifnecessary.
c) Pipe system is blocked. Clean pipework.
d) Pump capacity is not sufficientReplace with a larger capacity pump
4. Pump switches on and off frequently.
a) Pre-pressure in pressure tank is too low or too high.
Adjust pre-pressure in pressure tank. (0,9 x cut-in pressure)
b) Faulty footvalve.Check footvalve,replace if necessary.
c) The pressure switch differen-tial between the start and stoppressures is too small.
Increase the differential.
Flooded Suction: Wheninstallingabovegroundsuctionboosterpumps,the followingbasicrulesmustbeadheredto: •Inletpressure. •Avoidfrost. •Pumponlycleanwater. •Avoiddry-running •Anon-returnvalvemustbeinstalled. •Thesuctionpipemustbe100%airtight. •Thepumpandpipingmustbeprimedbeforestarting forthefirsttime.
8
DWS Product Guide 8-09.indd 8 8/18/2009 2:32:30 PM
-
Handbook Accessories
Fault Cause Remedy
5. The pump is running butthere is no pressure.
a) The pump and/or suction pipeis incorrectly primed.
Prime the pump and/or suction pipe with water.
b) The non-return valve or suctionpipe is leaky.
Replace the non-return valve and/or seal the suction pipe.
6. The pump does not deliver enough water.
a) The suction lift is too high.
Check the distance from the pump to the water level in the well. If possible, mount the pump nearer the water level.
b) Pressure switch settings are incor-rect Adjust settings accordingly
7. The pump has run for along time, but delivers no water when restarted after a standstill.
a) The pump and/or suction pipe is emptied of water.
Prime the pump and/or suction pipe with water.
8. Pump switches on and off frequently.
a) Pre pressure in pressure tank istoo low or too high.
Adjust pre-pressure in pressure tank. (0,9 x cut-in pressure)
b) Faulty foot valve. Check footvalve, replace if nec-essary.
c) The pressure switch differential between the start and stop pressures is too small.
Increase the differential.
Pressure Tanks: Keepthefollowingtipsinmind,whendealingwithinstallationsusingpressuretanks: •Stopthepumpandopenavalvetorelievethewaterpressurebeforecheckingthepre-chargepressureof thetank. •Fortraditionalon/offcontrolledpumps,thepre-chargepressureshouldequalthecut-inpressuremultipliedby0.9.
Installation note: YoushouldalwaysconsulttheInstructionandOperationmanualforeachspecificpumpduringinstallationandstart.
WebCAPS: FinddetailedinformationviatheGrundfoswebsite.WebCAPSisaneasytouseon-linetoolthatenablesusers tosizesystemsandaccessgeneralinformationaboutourproducts,whereyoucaneasilydownloadthemost up-todatepumpinformation.
9
DWS Product Guide 8-09.indd 9 8/18/2009 2:32:31 PM
-
DWS Product Guide 8-09.indd 10 8/18/2009 2:32:31 PM
-
EZ BoostTM System with BMQE Booster Pump,Tank, Pressure Sensor, and Controller
Product Guide EZ Boost™ System
DWS Product Guide 8-09.indd 11 8/18/2009 2:32:32 PM
-
Product Guide Page No.
Generaldata 13
Productrange 14
Materialsofconstruction 15
Typekey 15
15BMQEperformancecurves 16
22BMQEperformancecurves 17
30BMQEperformancecurves 18
Dimensions,weightsandelectricaldata 19
Dimensionalsketch 19
Technicaldata-BMQEpump 20
Technicaldata-EZBoostcontroller 21
Accessories 22
EZBoostQuickGuide 23
EZBoostSystemDiagram 23
EZBoostPre-Installation 24
ParallelOperation 25
Contents EZ BoostTM System
12
DWS Product Guide 8-09.indd 12 8/18/2009 2:32:33 PM
-
EZ BOOST SYSTEM
IntroductionTherearemanyapplicationswithinwatersupplywhereitisnecessarytoincreasethesystempressure.TheGrundfosEZBoostsystemistheoptimumsolutionforapplicationsrequiring:•Seallesspumps
•Quietoperationand/or
•Maintenance-freeoperation.
TheEZBoostsystemoffersthefollowingfeatures:
•Dry-runningprotection
•Highefficiencyofpumpandmotor
•Excellentwearresistance
•Softstarter
•Overvoltageandundervoltageprotection
•Overloadprotection
•Overtemperatureprotection.
•Variablespeed
•Electroniccontrolandcommunication.
Applications•Pressureboosting.
•Watertreatment.
Pumped liquidsThin, non-explosive liquids not containing abrasive par-ticlesor fibers. The liquidmustnotbeable toattack thepumpmaterialschemicallyormechanically.
Should thedensityand/orviscosityof thepumped liquidexceed thedensityand/or viscosityofwater, please con-tactGrundfos.
BMQE PumpThe pumps used for The Grundfos EZ Boost system aremodified SQE submersible pumps. The EZ Boost BMQEpump is an SQE pumpwith anMSE 3motor. Pump andmotorarecenteredinthe4”stainlesssteelsleeve.
BMQEpumpsare suitable forbothcontinuousand inter-mittentoperationforavarietyofpressureboostingappli-cations.
BMQE MotorTheMSE3motorsarebasedonstate-of-the-arttechnologywithin permanent magnets (PMmotor), which accountsfor the high motor efficiencies. In addition, the motorshaveabuilt-inelectronicunitwitha frequencyconverterforvariablefrequencyandsoftstarting.
Product Guide EZ BoostTM System
TheMSE3motors featureshighefficiencywithinawideload range. The high and flat efficiency curve of the PMmotor enables the same motor to cover a wide powerrange as opposed to conventional ACmotors. For BMQEpumps,thismeansfewermotorvariants.
EZ Boost ControllerTheBMQEpumpfeaturesvariablespeedwhichisofferedthroughfrequencycontrolviatheEZBoostcontroller.Asaconsequence,thepumpcanbesettooperateinanydutypoint intherangebetweentheminimumandmaximumperformancecurvesofthepump.EachBMQEpumpmustbeconnectedtoitsownEZBoostcontroller.
ItisalsopossibletooperatetheBMQEwithoutanEZBoostcontroller,thoughthefeaturesofferedwillbefewer.
Operating conditionsFlow: Max.39USGPM(8.9m3/h)
Head: Max.300ft(91.4m)
Temperature: Max.95°F(35°C)
Operatingpressure: Max.347PSI(23bar)
Inletpressure: Min.8PSI(0.55bar)
Sound-pressurelevel: ThesoundpressureleveloftheBMQE is lower than 74 db[A] at a distance of 3 feet (1meter).
It is recommended by Grundfos that the pump be installed with sound and vibration dampening equipment such as flexible piping adapters and anti-vibration mounting. The pump should not be mounted in or adjacent to living quar-ters. The pump can also be wrapped with sound- proofing insulation to reduce noise (see page 16, EZ Boost System Diagram).
BMQE Pump Sectional Drawing
Pos.1. Sleeve 5. SQEpump2. Dischargeconnection 6. Cableentry3. Suctionconnection 7. Centeringdevice4. MSE3motor 8. Airventscrew
6
2
5 4 7
31
8
13
DWS Product Guide 8-09.indd 13 8/18/2009 2:32:33 PM
-
Performance range, 60 Hz
Product range
Range BMQE 15 BMQE 22 BMQE 30
Nominalflowrate[USGPM(m3/h)] 15(3.4) 22(5.0) 30(6.8)
Temperaturerange +32to+95°F(0to+35°C)
Maximuminletpressure[PSI(bar)]
Maximumworkingpressure[PSI(bar)]
217(15)
347(23)
Maximumefficiency[%] 57 62 60
Flowrange[USGPM(m3/h)] 0to19(4.3) 0to33(7.5) 0to39(8.8)
Maximumpumppressure[ft(m/PSI)] 300(91.4)/130 290(88.4)/125 208(63.4)/90
Pipeconnection 1.25”NPTinlet/1”NPTdischarge
Product Guide EZ BoostTM System
0 5 10 15 20 25 30 35 Q [US GPM]
0
40
80
120
160
200
240
280
[ft]H
0
20
40
60
80
100
120
P[psi]
0 1 2 3 4 5 6 7 8 9 Q [m³/h]
0
20
40
60
80
H[m]
30 BMQE 05B-90
22 BMQE 05B-120
15 BMQE 05A-110
15 BMQE 07B-180
22 BMQE 05A-80
22 BMQE 10C-190
30 BMQE 10C-130
TK
0131
0133
04
14
DWS Product Guide 8-09.indd 14 8/18/2009 2:32:33 PM
-
Materials BMQ
SleevePos. Description Material AISI
90 Sleeve Stainlesssteel 316
91 Flange Stainlesssteel 304
92 CableentryStainlesssteel/FKM
304
93 Airventscrew Stainlesssteel 304
94 O-ring FKM
PumpPos. Description Material AISI
1 Valvecasing Polyamide/PVDF
1a Dischargechamber Stainlesssteel 304
1d O-ring NBRrubber
3 Valveseat NBRrubber
4a Emptychamber Polyamide/PVDF
6 Topbearing NBRrubber
7 Neckring Polyamide/PVDF
7a Lockring Stainlesssteel 310
7b Neckringretainer Polyamide/PVDF 310
9b Emptychamber Polyamide/PVDF
9c Bottomchamber Polyamide/PVDF
13ImpellerwithTCbear-ing
Polyamide/PVDF
14Suctioninterconnector
Polyamide/PVDF
14a Ring Stainlesssteel 304
16 Shaftwithcoupling Stainlesssteel 304
30 Cone Polyamide/PVDF
32 Guidevanes Polyamide/PVDF
39 Spring Stainlesssteel 316LN
55 Pumpsleeve Stainlesssteel 316
64 Primingscrew Polyamide/PVDF
70 Valveguide Polyamide/PVDF
86 Lipseal NBRrubber
87 Conecomplete Polyamide/PVDF
MotorPos. Description Material AISI
201 Stator Stainlesssteel 304
202 Rotor Stainlesssteel 304
202a Stopring PP
202b Filter Polyester
203 Thrustbearing Carbon
205 Radialbearing Ceramic/TC
220 Motorcablewithplug EPR
222a Fillingplug NBRrubber
224 O-ring FKM
225 Topcover PPS
232 Shaftseal NBRrubber
Type keyExample 22 BMQ E 05B 120
RatedflowinUSGPM
EZBoostpump
ElectronicallycontrolledpumpviaEZBoostcontroller
MotorHP
Headinfeetatratedflow
Product Guide EZ BoostTM System
1d
7a
1
70
2
39
3
1a
55
16
30
8687
6418
18b
18a
6
4a
9b
32
13
9c
7
14
14a
7b
9293
91
94
90
202a
202
202b
222a
232
203
224
205
225
201
220
233
15
DWS Product Guide 8-09.indd 15 8/18/2009 2:32:34 PM
-
Product Guide EZ BoostTM System
0 2 4 6 8 10 12 14 16 18 Q [US GPM]
0
50
100
150
200
250
300
[ft]H
0
20
40
60
80
100
120
140
P[psi]
0
20
40
60
80
100
H[m]
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Q [m³/h]
15 BMQE60 Hz
07B-180 (5-stage)
05A-110 (3-stage)
0 2 4 6 8 10 12 14 16 18 Q [US GPM]
0.0
0.1
0.2
0.3
[hp]P2
0
20
40
60
[%]Eta
0.0
0.1
0.2
P2[kW]
P2
Eta
TK
0130
9833
04
16
DWS Product Guide 8-09.indd 16 8/18/2009 2:32:34 PM
-
Product Guide EZ BoostTM System
0 5 10 15 20 25 30 Q [US GPM]
0
50
100
150
200
250
300
[ft]H
0
20
40
60
80
100
120
140
P[psi]
0
20
40
60
80
100
H[m]
0 1 2 3 4 5 6 7 Q [m³/h]
05A-80 (2-stage)
05B-120 (3stage)
10C-190 (5-stage)
0 5 10 15 20 25 30 Q [US GPM]
0.0
0.2
0.4
0.6
[hp]P2
0
20
40
60
[%]Eta
0
0
0
P2[kW]
P2
Eta
TK
0130
9933
04
17
DWS Product Guide 8-09.indd 17 8/18/2009 2:32:34 PM
-
Product Guide EZ BoostTM System
0 5 10 15 20 25 30 35 Q [US GPM]
0
20
40
60
80
100
120
140
160
180
200
220
[ft]H
0
10
20
30
40
50
60
70
80
90
P[psi]
0 1 2 3 4 5 6 7 8 9 Q [m³/h]
0
10
20
30
40
50
60
70
H[m]
05B-90 (2-stage)
10C-130 (3-stage)
0 5 10 15 20 25 30 35 Q [US GPM]
0.0
0.2
0.4
0.6
[hp]P2
0
20
40
60
[%]Eta
0
0
0
P2[kW]
P2
Eta
TK
0131
0033
04
18
DWS Product Guide 8-09.indd 18 8/18/2009 2:32:34 PM
-
Product Guide EZ BoostTM System
ModelMaterialnumber
Max. motor output[P2] Rated
Voltage
Rated current
[A]
Locked rotorcurrent
[A]
Shipping weight[lb (kg)]
Shippingvolume
[ft3 (m3)]hp kW
15BMQE05A-110 91128524 0.845 0.63 110-115 9.2 11.1 26(11.8)
0.9(0.025)
22BMQE05A-80 91128527 0.845 0.63 110-115 7.8 11.1 26(11.8)
15BMQE05A-110 91128525 0.845 0.63 200-240 4.6 5.0 26(11.8)
15BMQE07B-180 91128526 1.408 1.05 200-240 7.1 8.0 29(13.2)
22BMQE05A-80 91128528 0.845 0.63 200-240 3.9 5.0 26(11.8)
22BMQE05B-120 91128529 1.408 1.05 200-240 5.6 8.0 29(13.2)
22BMQE10C-190 91128530 2.320 1.73 200-240 9.9 11.1 31(14.1)
30BMQE05B-90 91128531 1.408 1.05 200-240 6.0 8.0 31(14.1)
30BMQE10C-130 91128533 2.320 1.73 200-240 9.5 11.1 31(14.1)
Weights and electrical data
43.3"/1100
Cableentry
Airventscrew
0.8"/20.5
ø4.
6"/1
16
ø3.
5"/8
8.9
1.25"NPT
1.0"NPT
Dimensional sketch [in/mm]
19
DWS Product Guide 8-09.indd 19 8/18/2009 2:32:35 PM
-
Product Guide EZ BoostTM System
Main power supply to pump 1 x 200-240 V –10%/+6%, 60 Hz1 x 110-115 V –10%/+6%, 60 Hz
Starting Soft starting.
Stopping SoftstoppingwhenstoppedbytheEZBoostcontroller
Run-uptime Maximum:2seconds.Nolimitationtothenumberofstarts/stopsperhour.
Motorprotection Builtintothepump.Protectionagainst:DryrunningOvervoltageandundervoltage230Vcutsoutat<150Vand>280V115Vcutsoutat<75Vand>150VOverloadOvertemperature
Soundpressurelevel Thesoundpressurelevelis<74db[A]atadistanceof3feet(1meter).It is recommended by Grundfos that the pump be installed with sound and vibration dampening equipment such as; flexible piping adapters and anti-vibration mounting. The pump should not be mounted in or adjacent to living quarters. The pump can also be wrapped with sound proofing insulation to reduce noise. (See page 16, EZ Boost System Diagram.)
Resetfunction BMQEpumpscanberesetviaEZBoostcontroller.
Powerfactor PF=1.
Operationviagenerator ItisrecommendedthatthegeneratoroutputisequaltothemotorinputpowerP1[kW]plus50%;min.P1+10%,however.
Pipeconnection 1.25”NPTinlet/1”NPTdischarge.
Strainer Holesofthestrainer:ø0.09”(2.3mm)
Marking ULListed,CE(SQEPumpwithMSE3motoronly)
Technical data - BMQE pump
20
DWS Product Guide 8-09.indd 20 8/18/2009 2:32:35 PM
-
Product Guide EZ BoostTM System
EZ Boost ControllerThe EZ Boost controller is a control and communicationunitespeciallydevelopedfortheBMQEboosterpumps inconstantpressureapplications.
TheEZBoostcontrollerprovides:
• FullcontroloftheBMQEpumps
• Two-waycommunicationwiththeBMQEpumps
• Possibilityofadjustingthepressure
• Alarmindication(LED)whenserviceisneeded
• The possibility of starting, stopping and resetting the pumpsimplybymeansofapush-button
TheEZBoostcontrollercommunicateswiththepumpviapower linecommunication,meaningthatnoextracablesarerequiredbetweentheEZBoostcontrollerandtheBMQEpump.
TheEZBoostcontroller featuresthefollowing indications(seedrawingbelow):1. Flowindicator
2. Systempressuresetting
3. SystemON/OFF
4. Buttonlockindicator
5. Dry-runningindicator
6. Serviceneededincaseof:
–Nocontacttopump –Overvoltage –Undervoltage –Speedreduction –Overtemperature –Overload –Sensordefective
TheEZBoostcontroller incorporatesexternalsignal inputforpressure sensorandapumpstatus relay forusewithdevisesdependantonpumpstatus.
Voltage 1x100-240V–10%/+6%,60Hz
Powerconsumption
5W
Currentconsumption
Maximum130mA
Enclosureclass NEMA3R(IP55)
Ambienttemperature
Inoperation:-22to+122°F(-30to+50°C)duringstorage:-22to+140°F(-30to+60°C)
Relativeairhumidity
95%
PumpcableMaximumlengthbetweenEZBoostcontrol-lerandpump:650ft(198m).
Back-upfuse Maximum:16A
Marking ULListed,CE
Load Max.100mA
2 3
4
1
5
6
Powersupplyentry
Submersibledropcableentry
Pressuresensorentry
9 3/15 in. (232 mm) 4 1/2 in. (114 mm)
7 11
/16
in. (
195
mm
)
21
DWS Product Guide 8-09.indd 21 8/18/2009 2:32:35 PM
-
Product Guide EZ BoostTM System
Accessories
EZ Boost constant pressure kit
Description Rating Materialnumber
EZBoostcontrollerandpressuresensor 40to100PSIsettingrange 91128636
EZ Boost controller
Description Rating Materialnumber
EZBoostcontroller 40to100PSIsettingrange 91121987
Sensor
Description Rating Materialnumber
PressuresensorkitforEZBoostcontroller 0to120PSI,1/2”NPT 96437852
Diaphragm tank
DutyrangePre-chargepressure: 40PSIMax.operatingpressure: 150PSIMax.liquidtemperature: 200°F
MaterialsLiner: PolypropyleneConnection: Lead-freebrassTank: Stainlesssteel,AISI304
DescriptionG
connectionD
[in(mm)]H
[in(mm)]Weight[lbs(kg)]
Materialnumber
Diaphragmtank,2gallon
3/4”NPT 8(203) 12.63(321) 5(2.3) 91121984
G
D
H
22
DWS Product Guide 8-09.indd 22 8/18/2009 2:32:36 PM
-
Product Guide EZ BoostTM System
EZ Boost Quick GuideEZ Boost Quick Selection GuideExample:1. Themaximumdemandis15GPM(3.4m3/h).
2. Thepressurerequiredis70PSIsystempressure atthetapsinthebuilding.
3. Thenormalminimuminletpressure(e.g.city pressure)is20PSI.
4. Theadditionalboostrequiredis50PSIat15GPM (3.4m3/h).
5. Selecta15BMQE05A-110.
EZ Boost System DiagramTheEZBoostConstantPressureSystemshouldconsistof:
Pos.1. EZBoostBMQEpump
2. EZBoostcontroller
3. Diaphragmtank (recommendedsize2U.S.gallons(8liter)/130psi)
Additional(boost)pressurerequired
5 10 15 20 25 30 35 39Flowrequiredingallonsperminute(GPM)
inPSI908070605040302010
15 BMQE 05A-11015 BMQE 05A-110
30 BMQE 05B-9030 BMQE 05B-90
30 BMQE 10C-13030 BMQE 10C-130
22 BMQE 10C-19022 BMQE 10C-190
22 BMQE 05B-12022 BMQE 05B-120
22 BMQE 05A-8022 BMQE 05A-80
15 BMQE 07B-18015 BMQE 07B-180
4. Pressuresensor
5. Mountingbrackets
6. Flexconnector
23
DWS Product Guide 8-09.indd 23 8/18/2009 2:32:36 PM
-
PRE-INSTALLATION
A guide to the EZ Boost SystemThe EZ Boost Constant Pressure System automaticallybalances water surges and equalizes flow and pressureaccording to consumption. In other words, the systemmaintains a constant water pressure in spite of varyingwater consumption. The pressure is registered bymeansof the pressure sensor and transmitted to the controller.ThecontrolleradjuststheEZBoostBMQEpumpperform-anceaccordingly.TheEZBoostConstantPressureSystemfeatures:
• Quickandeasyinstallation:ready-to-usesystem requiringminimumspace
• Highuserconvenience:constantpressureregardlessof waterconsumption
• Easilyadjustablepressurelevel:pushbuttoncontrol
• Continuouscontrolandmonitoringofpumpoperation
• Integrateddry-runningprotection
• Integratedoverloadprotection
• Integratedprotectionagainstovervoltageandunder voltage
• Softstartsystem
FunctionWhena tap isopened, thepressure in the tankwill starttodrop.Thesystemmaintainsaconstantpressurewithinthemaximumpumpperformanceinspiteofvaryingwaterconsumption.
Thepressureisregisteredbymeansofthepressuresensor,which transmits a signal to the controller. The controlleradjusts the pump performance accordingly to maintainconstantpressurebychangingthepumpspeed.
Atlowflowthepressurewilldropslowly.Whenthepres-sureinthetankis7PSIbelowthesetpoint,thepumpwillstart.When the pressure is 7 PSI above the setpoint, thepumpwillstop.
EventhoughtheEZBoostcontrolleriscontrollingthepres-surewithin±3PSI,largerpressurevariationsmayoccurinthe system. If the consumption is suddenly changed, e.g.if a tap is opened, the water must start flowing beforethe pressure can bemade constant again. Such dynamicvariations depend on the pipe work, but, typically, theywillliebetween7and14PSI.Ifthedesiredconsumptionishigherthanthequantitythepumpisabletodeliveratthedesiredpressure, thepressure follows thepumpcurveasillustratedinthefarrightoffig.1.
Fig.1
At largeflowrates,thepressurewilldropquicklyandthepumpwill start immediatelyandmaintainconstantpres-sure.Whenthesystemisrunning,theEZBoostcontrollermakessmalladjustmentstothepressuretodetectwhetherthereisconsumption.Ifthereisnone,thepumpwillsimplyrefillthetankandstopafterafewseconds.
Pressure
Flow
A
Stop+7PSI
Start-7PSI
Controlling±3PSI
Dynamicvariations±7PSI
GPM0.8
A=Pressuresetting
Product Guide EZ BoostTM System
24
DWS Product Guide 8-09.indd 24 8/18/2009 2:32:37 PM
-
1
2
Air escape valve
Diaphragm tank
EZ Boost controller
Isolation valve
Pressure gauge
Pressure sensor
BMQE pumps connected in parallelWhen connecting BMQE pumps in parallel as shown infig.5,a separate EZ Boost controller must be used on each BMQE. Set the pressure on one BMQE 10 PSI lower thantheother.
For BMQE pumps connected in parallel, mounted aboveeach other, it is recommended to connect the pipes asshowninfig.5.ThislayoutensuresthattheBMQEpumpsarefilledwithwaterbeforestarting.
Fig.5 BoosterunitwithtwoBMQEpumps connectedinparallel,mountedaboveeach other.
Notes:• AllBMQEmodulesaresuppliedwithanon-return
valve.
• BMQEmodulesconnectedinparallelmayalsobe installedvertically.
• Asventingproblemsmayariseinsuchinstallations,itis advisabletoinstallsuitableairventdevices.
• TheBMQEshouldbepositionedwiththedischargeand airventatthetopwheninstalledvertically.
• WhenthemaximumflowforBMQEpumpsinparallel will exceed 35 GPM, a 4-gallon or two 2-gallon dia- phragmtank(s)shouldbeused.
Product Guide EZ BoostTM System
25
DWS Product Guide 8-09.indd 25 8/18/2009 2:32:37 PM
-
DWS Product Guide 8-09.indd 26 8/18/2009 2:32:37 PM
-
Product Guide MQ
MQFlowbasedpressureboostingsystem
60Hz
DWS Product Guide 8-09.indd 27 8/18/2009 2:32:39 PM
-
General data Page No.
Application 29
Typekey 29
Pumpedliquids 29
Operatingconditions 29
Technicaldata 29
Featuresandbenefits 29
Controlpanel 30
Productrange 30
Technical data
Electricaldata 30
Dimensions 30
Materialspecifications 31
Floodedsuctionperformancecurves 32
MQ3-35suctionliftperformancecurves 33
MQ3-45suctionliftperformancecurves 34
Accessories 35
28
Contents
DWS Product Guide 8-09.indd 28 8/18/2009 2:32:39 PM
-
29
Product Guide
ApplicationThe MQ pump is designed for water supply and pressure boosting ...
• homes
• cabins,cottages
• onfarmsaswellas
• gardens
The pump is suitable for pumping of potable water and rain water.
Type KeyExample MQ 3 -35 A - B - A -BVBP
Pump range
Rated flow [m³/h]
Max. head [m]
Code for pump versionA: Standard
Code for pipework connectionB: External thread
Code for materialsA: Standard
Code for shaft seal
Pumped liquidsPotable water, rain water or other clean, thin, non-aggressive liquids not containing solid particles or fibers.
Operating conditionsSystem pressure: Max. 109 psi (7.5 bar).
Inlet pressure: Max. 44 psi (3 bar).
Suction lift: Max. 26 ft (8 m).
Liquid temperature: 32°F to +95°F (0°C to +35°C).
Ambient temperature: 32°F to +113°F (0°C to +45°C).
Technical dataMains voltage:
• 115Vmodels: 1x110-120V,60Hz • 230Vmodels: 1x220-240V,60Hz.
Voltage tolerances: –10% / +6%.
Enclosure class: IP54.
Insulation class: B.
Sound pressure level: ≤ 55 dB(A).
Agency approvals: UL, cUL
Features and benefits• Complete system
The MQ is a complete, all-in-one unit, incorporating pump, motor, diaphragm tank, pressure and flow sensor, controller and check valve. The controller ensures that the pump starts auto matically when water is consumed and stops auto matically when the consumption ceases. In addition, the controller protects the pump in case of faults.
• Installation Due to its compact design, the pump does not take up much space and is easy to install. No space around the pump is required.
• Simple operation The pump features a user-friendly control panel with ON/OFF button and indicator lights for indication of the operational state of the pump.
• Self-priming pump As it is self-priming, the MQ is able to pump water from a level below the pump. Provided it is filled with water, the pump is able to lift water from a depth of 26 ft (8 m) in less than 5 minutes. This facilitates installa tion and start-up of the pump and provides more re liable water supply in installations where there is a risk of dry running and leakages in suction hose or pipes.
• Built-in protective functions If exposed to dry running, excessive temperature, or any overload condition the pump will stop automatically, thus preventing a motor burnout.
• Automatic reset The pump features an automatic reset function. In case of dry running or similar alarm, the pump will stop. Restarting will be attempted every 30 minutes for a period of 24 hours. The reset function can be de activated.
• Low noise level Thanks to its hydraulic design and internal cooling, the pump is very quiet, which makes it suitable for many applications.
• Pressure tank The built-in pressure tank reduces the number of starts and stops in case of leakages in the pipe sys tem, causing less wear on the pump.
• Maintenance No maintenance of the pump is required.
MQFlow Based Pressure Boosting System
DWS Product Guide 8-09.indd 29 8/18/2009 2:32:39 PM
-
30
Product Guide
Control panel operation
1
3
5
6
4
2
TM0
1 9
684
26
00
Pos. Function Description
1 ON/OFF buttonThe Pump is started and stopped by means of the ON/OFF button.
2
Power indicator lights
Indicates that the pump is ready for operation (green).
3Indicates that the pump is on standby (red).
4 Pump ON (green) Indicates that the pump is running.
5 Auto reset (green)
Indicates that the auto reset function is active. After an alarm, restarting will be attempted every 30 minutes for a period of 24 hours.
6 Alarm (red)Indicates that the pump is in alarm state. Manual resetting is possible by pressing the ON/OFF button.
MQFlow Based Pressure Boosting System
PartNumber
Model PH & VAMPS P2 Weight
NetPounds
CordConnection
PlugRun Start W HP
96860172 MQ 3-35 1X110-120V 8 29 585 0.75 30.17.54’ - 2300mm SJTW-A
18 awgUL Approved NEMA
5-15P - V125
96860195 MQ 3-45 1X110-120V 10 29 725 1 30.27.54’ - 2300mm SJTW-A
18 awgUL Approved NEMA
5-15P - V125
96860201 MQ 3-35 1X220-240V 4 15 565 0.75 30.17.54’ - 2300mm SJTW-A
18 awgUL Approved NEMA
6-15P - V250
96860207 MQ 3-45 1X220-240V 4.8 15 716 1 30.27.54’ - 2300mm SJTW-A
18 awgUL Approved NEMA
6-15P - V250
Product range and electrical data
Dimensions
TM0
11 9
799
DWS Product Guide 8-09.indd 30 8/18/2009 2:32:40 PM
-
31
Product Guide MQFlow Based Pressure Boosting System
Material specification
Pos. Components Material
2 Support flange PP+30% Glass Fiber HB (f1)
4 Chamber PPO+20% Glass Fiber
7 Drain and priming plug PPO+20% Glass Fiber
10 Self-priming valve PP+30% Glass Fiber
14 Self-priming part PPO+20% Glass Fiber
16 Pump sleeveStainless steel,DIN W.-Nr. 1.4301, AISI 304
42 Tank cover PP+30% Glass Fiber HB (f1)
49 Impeller PPO +20% Glass Fiber-PTFE
51 Motor cover PP+30% Glass Fiber HB (f1)
65 Non-return valve POM+25% Glass Fiber
92 ClampStainless steel,DIN W.-Nr 1.4301, AISI 304
100a Discharge port PPO+20% Glass Fiber
POM: Polyoximetylen
NR-rubber: Natural Rubber
PPO: Polyphenylene Oxides
PP: Polypropylene
NBR-rubber: Nitrile-Butadiene Rubber
PartNumber
Model PH & VAMPS P2 Weight
NetPounds
CordConnection
PlugRun Start W HP
96860172 MQ 3-35 1X110-120V 8 29 585 0.75 30.17.54’ - 2300mm SJTW-A
18 awgUL Approved NEMA
5-15P - V125
96860195 MQ 3-45 1X110-120V 10 29 725 1 30.27.54’ - 2300mm SJTW-A
18 awgUL Approved NEMA
5-15P - V125
96860201 MQ 3-35 1X220-240V 4 15 565 0.75 30.17.54’ - 2300mm SJTW-A
18 awgUL Approved NEMA
6-15P - V250
96860207 MQ 3-45 1X220-240V 4.8 15 716 1 30.27.54’ - 2300mm SJTW-A
18 awgUL Approved NEMA
6-15P - V250
Pos. Components Material
101 Suction port PPO+20% Glass Fiber
103104
Shaft seal:Stationary androtating part
Carbon/ceramics/NBR rubber
149 Insulation disc PA 5VA (Polyammide)
150
ShaftStainless steel,DIN W.-Nr 1.4005, AISI 416
Motor sleeveStainless steel,DIN W.-Nr 1.4301, AISI 304
164 Terminal box cover PP+30% Glass Fiber 5VA (f1)
174a Pressure switchPOM+25% Glass Fiber / SIL Rubber (Silicone Rubber)
Pressure switch membrane SIL Rubber - Silicone Rubber.
180 Motor body PP+30% Glass Fiber 5VA (f1)
184 Flow sensor POM+25% Glass Fiber
O-rings NBR-rubber
101 49 16 4 2
100a
14
7
92
150
51
184164 174a 42
103104
65
10180
DWS Product Guide 8-09.indd 31 8/18/2009 2:32:42 PM
-
32
Product Guide MQFlow Based Pressure Boosting System
Flooded suction (0 PSI inlet) performance curves*
*See suction lift performance curves for installations with water level below intake.
DWS Product Guide 8-09.indd 32 8/26/2009 10:58:47 AM
-
33
Product Guide MQFlow Based Pressure Boosting System
MQ 3-35 Suction lift performance curves
0 4 8 12 16 20 Q [US GP M]
0
5
10
15
20
25
30
35
40
45
p [psi]
0 1 2 3 4 Q [m³/h]
0
10
20
30
40
50
60
70
80
90
100
110
H [ft]
0
8
16
24
32
40
[m]H
MQ 3-35 model B60 Hz
26.2 Ft
23.0 Ft
19.7 Ft
13.1 Ft
6.6 Ft
3.3 Ft
0 Ft
Provided it is filled with water, the pump is able to lift water from a depth of 26 ft (8 m) in less than 5 minutes.
MQ 3-3560 Hz
DWS Product Guide 8-09.indd 33 8/18/2009 2:32:43 PM
-
34
Product Guide MQFlow Based Pressure Boosting System
MQ 3-45 Suction lift performance curves
0 4 8 12 16 20 Q [US GP M]
0
10
20
30
40
50
60
p[psi]
0 1 2 3 4 Q [m³/h]
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
H[ft]
0
8
16
24
32
40
[m]H
MQ 3-45 model B60 Hz
26.2 Ft
23.0 Ft
19.7 Ft
13.1 Ft
6.6 Ft
3.3 Ft
0 Ft
Provided it is filled with water, the pump is able to lift water from a depth of 26 ft (8 m) in less than 5 minutes.
MQ 3-4560 Hz
DWS Product Guide 8-09.indd 34 8/18/2009 2:32:43 PM
-
35
Product Guide MQFlow Based Pressure Boosting System
Accessories
Protection Cover:Designed to protect the MQ Key Pad and electronics in outdoor applications.
Protection cover is required for outdoor applications where the MQ is exposed to the elements.
The protection cover is sold as an accessory PN 96693071.
The cover is made of polypropylene and is a snap fit to the MQ. Two Velcro tabs are included with the accessory to help adhear the back end of the cover to the pump.
DWS Product Guide 8-09.indd 35 8/18/2009 2:32:44 PM
-
36
Basic Line Jets
DWS Product Guide 8-09.indd 36 8/18/2009 2:32:44 PM
-
37
JPF,JPS,JDFShallowWell,DeepWelland
ConvertibleJetPumps60Hz
Product Guide Basic Line Jets
DWS Product Guide 8-09.indd 37 8/18/2009 2:32:45 PM
-
General data Page No.
Performancerange 39
Productrange 40
Applications 41
Pumps 41
Motors 41
Pumpedliquid 41
Agencyapprovals 41
Mountingposition 41
Electricaldata 42
Materialsofconstruction 43
Technical data
JPF 2A, 3A, 4A, 41A Shallow Well Cast Iron 46
DimensionsandWeights 46
PerformanceChart 46
PerformanceCurves 47
JPF 5A, 7A Convertible Cast Iron 48
DimensionsandWeights 48
ConversionInstructions 48
PerformanceChart 49
PerformanceCurves 49
DeepWellPerformanceChart 50
JPS 2A, 4A Shallow Well Stainless Steel 51
DimensionsandWeights 51
PerformanceChart 51
PerformanceCurves 52
JDF 2A, 4A Deep Well Cast Iron 53
DimensionsandWeights 53
EjectorDimensions 53
PerformanceChart 54
JPF3A Pump Tank Package Cast Iron 55
DimensionsandWeights 55
PerformanceChart 55
JPS2A Pump Tank Package Stainless Steel 56
DimensionsandWeights 56
PerformanceChart 56
38
Contents Basic Line Jets Basic Line Jets
DWS Product Guide 8-09.indd 38 8/18/2009 2:32:45 PM
-
39
�
�
�
Performance range
* Capacities given are for near-sea level installations.
Product Guide Basic Line Jets
DWS Product Guide 8-09.indd 39 8/18/2009 2:32:46 PM
-
40
Product Guide
Product rangeModel JPF 2-A JPF 3-A JPF 4-A JPF 41-A JPF 5-A JPF 7-A JPS 2-A JPS 4-A JDF 2-A JDF 4
Flow range (U.S. gpm) 1.7-13 1.7-12.2 1.7-16 1.8-21 2.6-22 2.6-35 1.7-17 3.5-28.2 1.8-10.3 0.75-13.1
Max. pump head H(ft) 135 170 172 185 200 200 140 155 145 167
Max. working pressure (psi) 87 87 87 87 110 110 110 110 87 87
Motor power (hp), Nominal 1/3 1/2 3/4 1 1.5 2 1/2 1 1/2 3/4
Maximum Fluid Temperature range 14°F to 104°F (-10 to 40°C)*
Maximum lift, Ft (Sea level) 26 26 26 26 140 140 26 26 70 80
Maximum Ambient Temp 34°F to 104°F (1 to 40°C)
Factory Pressure -Switch setting (PSI) 20-40 30-50 30-50 40-60 50-70 50-80 30-50 30-50 30-50 30-50
Storage Temp 14°F to 104°F (-10 to 40°C)
Relative Humidity 95%
Maximum Starts per hour 20
*Minimum fluid temperature on water, 32°F (0°C)
Basic Line Jets Basic Line Jets
DWS Product Guide 8-09.indd 40 8/18/2009 2:32:46 PM
-
41
Product Guide
ApplicationsShallowwell,DeepwellandConvertiblepumpappli-cations.Grundfosjetpumpsareself-primingcentrifu-galpumpssuitablefordomesticwatersupplysystems,lightagriculturalandindustrialwatertransferapplica-tions
PumpsJPF2A, JPF3A, JPF4A, JPF41A Pumps:Ruggedcastironconstruction.Single-stageshallowwellself-primingcentrifugalpumps.Endsuction,topdischargearrangementandTechnopolymerimpeller.Pumphasbuilt-inejectorcompletewithcleanoutporttoclearblockagesfromnozzle.Convenientprimingplugforeaseofprimingandairelimination.Ceramic-Carbonbellowsmechanicalsealensurestrouble-freeoperation.
JPF5A & JPF7A Pumps:Ruggedcastironconstruction.Multistageconvertibleself-primingcentrifugalpumps.Endsuction,topdis-chargearrangementwithdetachableejectorassemblyfordeepwellapplicationsandTechnopolymerimpel-lers.Convenientprimingplugforeaseofprimingandairelimination.Ceramic-Carbonbellowsmechanicalsealensurestrouble-freeoperation.
JDF2A & JDF4A Pumps:Ruggedcastironconstruction.Single-stagedeepwellself-primingcentrifugalpumps.Endsuction,topdischargearrangementandTechnopolymerimpel-ler.PumphasseparatedeepwellportforconnectiontoDeepWellejectorkit.Convenientprimingplugforeaseofprimingandairelimination.Ceramic-Carbonbellowsmechanicalsealensurestrouble-freeopera-tion.
JPS2A & JPS4A Pumps:Corrosionresistantstainlesssteelconstruction.Singlestageshallowwellself-primingcentrifugalpumps.Endsuction,topdischargearrangementandTechnopolymerimpeller.Ceramic-Carbonbellowsmechanicalsealensurestrouble-freeoperation.
MotorsAll jet pump motors are totally enclosed and fan-cooled design for quiet operation and superior protec-tion in harsh environments. Stainless steel motor shaft offers excellent corrosion resistance. Double, oversized greased ball bearings are maintenance-free sealed for life. All motors have built-in thermal overload protec-tion and are capacitor-run, with no switches to fail. Drive end motor bearing protected by durable lip seal. InsulationclassF,motorprotectionIP44,terminalboxprotectionIP55.
Pumped LiquidOnlyuseonclean,non-viscous,non-aggressive,non-explosiveliquids.Pumpnottobeusedonpoolwaterapplicationsorhydrocarbontransfer(i.e.diesel,gaso-line,etc).
Agency Approvals:CSA-StdC22.2No108,No77-95.
Mounting Position:Shaftinhorizontalpositiononlyforallpumps.
Basic Line Jets
DWS Product Guide 8-09.indd 41 8/18/2009 2:32:46 PM
-
42
Product Guide
Electrical Data:
Model
Electrical Data
Voltage 60 Hz
kWMaximum
hpNominal
S.F.I
AmpsCapacitor
µF
JPF2A 115 0.65 1/3 1.75 6 40
JPF2A 230 0.65 1/3 1.75 3 10
JPF3A 115 0.85 1/2 1.6 7.5 20
JPF3A 230 0.85 1/2 1.6 3.8 12.5
JPF4A 115 1.10 3/4 1.5 10 64
JPF4A 230 1.10 3/4 1.5 5 16
JPF41A 115 1.31 1 1.4 12 80
JPF41A 230 1.31 1 1.4 6 20
JPF5A 230 1.70 1.5 1.3 8 31.5
JPF7A 230 2.40 2 1.2 11 40
JPS2A 115 0.88 1/2 1.6 7.6 50
JPS2A 230 0.82 1/2 1.6 3.7 12.5
JPS4A 115 1.6 1 1.4 13.6 80
JPS4A 230 1.53 1 1.4 7 20
JDF2A 115 0.75 1/2 1.6 7 50
JDF2A 230 0.75 1/2 1.6 3.4 12.5
JDF4A 115 0.88 3/4 1.5 8 64
JDF4A 230 0.88 3/4 1.5 4 16
Basic Line Jets Basic Line Jets
DWS Product Guide 8-09.indd 42 8/18/2009 2:32:46 PM
-
43
Product Guide
JPF 2A, 3A, 4A, 41A* Shallow Well
Materials: JPF 2A, 3A, 4A, 41A Shallow Well
Descriptions Material
Motor Stool Cast Iron
Shaft Seal Carbon/Ceramic/NBR
O-Rings & Gaskets NBR
Base Plate Cast Iron
Pump Housing Cast Iron
Impeller Noryl©
Motor Shaft Stainless Steel AISI 416
Tubing Polyethylene
Diffuser Noryl©
Venturi Tube and Nozzle Noryl©
Note:Noryl©isaregisteredtrademarkofGeneralElectricCompany
JPF 5A, 7A Convertible*
Materials: JPF 5A, 7A Convertible
Descriptions Material
Motor Stool Cast Iron
Shaft Seal Carbon/Ceramic/NBR
Motor Shaft Stainless Steel AISI 303
O-Rings & Gaskets NBR
Base Plate Cast Iron
Pump housing Cast Iron
Impellers Noryl©
Tubing Polyethylene
Diffuser Noryl©
Venturi Tube and Nozzle Noryl©
Note:Noryl©isaregisteredtrademarkofGeneralElectricCompany
*Available in Canada*41A available in Canada
Basic Line Jets
DWS Product Guide 8-09.indd 43 8/18/2009 2:32:47 PM
-
44
Product Guide
JPS 2A, 4A Shallow Well
Materials: JPS 2A, 4A Shallow WellDescriptions Material
Motor Stool Cast Iron
Shaft Seal Carbon/Ceramic/NBR
O-Rings & Gaskets NBR
Base Plate Steel
Pump housing Stainless Steel AISI 304
Impeller Noryl©
Motor Shaft Stainless Steel AISI 303
Tubing Polyethylene
Seal cover Stainless Steel AISI 304
Nozzle-Venturi Diffuser Assembly
Noryl©
Note:Noryl©isaregisteredtrademarkofGeneralElectricCompany
JDF 2A, 4A Deep Well
Materials: JDF 2A, 4A Deep WellDescriptions Material
Motor Stool Cast Iron
Shaft Seal Ceramic/Ceramic/NBR
O-Rings & Gaskets NBR
Base Plate Cast Iron
Pump housing Cast Iron
Impeller Noryl©
Tubing Polyethylene
Motor Shaft Stainless Steel AISI 303
Diffuser Noryl©
Venturi Tube Noryl©
Note:Noryl©isaregisteredtrademarkofGeneralElectricCompany
Basic Line Jets Basic Line Jets
DWS Product Guide 8-09.indd 44 8/18/2009 2:32:49 PM
-
45
Product Guide
JPF3A Pump package*Cast Iron
*Available in Canada
Materials: JPF3A Pump PackageDescriptions Material
Motor Stool Cast Iron
Shaft Seal Carbon/Ceramic/NBR
O-Rings and Gaskets NBR
Base Plate Cast Iron
Pump Housing Cast Iron
Impeller Noryl©
Motor Shaft Stainless Steel AISI 416
Tubing Polyethylene
Diffuser Noryl©
Venturi Tube and Nozzle Noryl©
Tank Stainless Steel AISI304
Bladder Butyl
Note:Noryl©isaregisteredtrademarkofGeneralElectricCompany
JPS2A Pump package*Stainless Steel
*Available in Canada
Materials: JPS2A Pump PackageDescriptions Material
Motor Stool Cast Iron
Shaft Seal Carbon/Ceramic/NBR
O-Rings and Gaskets NBR
Base Plate Steel
Pump Housing Stainless Steel AISI304
Impeller Noryl©
Motor Shaft Stainless Steel AISI 303
Tubing Polyethylene
Seal Cover Stainless Steel AISI304
Nozzle-Venturi Diffuser Assembly
Noryl©
Tank Stainless Steel AISI304
Bladder Butyl
Note:Noryl©isaregisteredtrademarkofGeneralElectricCompany
Basic Line Jets
Features and BenefitsAssembled jet-pump and tank package. Available with rugged 1/2 hp cast iron pump or corrosion-resistant stainless steel pump, mounted on a stainless steel, 6.3 gallon (24 litre) diaphragm tank. Package comes complete with pressure switch, gauge, hose and fittings, ready for installation.
DWS Product Guide 8-09.indd 45 8/18/2009 2:32:49 PM
-
46
Dimensional Drawings
Dimensions and WeightsPump Type
Motor Data D1Suction
NPT
D2Disch.NPT
Dimensions (inches) Ship Wt. (lbs)
Ship Vol. (Cu Ft.) HP S.F. PH Volts A B B1 C E F G H H1 IØ
JPF2A 1/3 1.75 1 115 or 230 1’’ 1’’ 16.2 7.1 9.1 5.5 8.9 0.6 5.5 8.5 6.0 0.38 35 1.5JPF3A 1/2 1.6 1 115 or 230 1’’ 1’’ 16.2 7.1 9.1 5.5 8.9 0.6 5.5 8.5 6.0 0.38 36 1.5JPF4A 3/4 1.5 1 115 or 230 1’’ 1’’ 17.3 7.1 9.1 5.5 8.9 0.6 5.5 8.5 6.0 0.38 41 1.5
JPF41A 1 1.4 1 115 or 230 1’’ 1’’ 17.3 7.1 9.1 5.5 8.9 0.6 5.5 8.5 6.0 0.38 43 1.5
Shallow Well Performance Chart
Model HP Depth to Water
Discharge Pressure (PSI) Shut-off
(PSI)
Pressure Switch Settings (PSI)
20 30 35 40 45 50 55
Capacities (U.S. gpm)*
JPF2A 1/3
5 11 7 6 4 3 2 58
20-4010 10 7 6 4 3 2 56.515 9 7 6 4 3 2 5420 7 6 5 4 3 2 51.525 5 4 3 2 1 49
JPF3A 1/2
5 12 11 11 10 7 6 4 73.5
30-5010 10.5 10 10 9.5 7 6 4 7115 9 8.5 8 8 7 6 4 68.520 7.5 7 7 7 6.5 6 4 6625 5 5 5 5 4.5 4 4 63.5
JPF4A 3/4
5 15 14 14 13 10 8.5 6 75.5
30-5010 13 12.5 12.5 12 10 8.5 6 7315 11 11 10 10 10 8 6 70.520 9 9 9 8.5 8 7 6 6825 6 6 6 6 5 5 5 65.5
JPF41A 1
5 21 20.5 20 20 20 19 17.5 86.5
40-6010 19 18.5 18 18 17.5 17.5 17 8415 16 16 16 15.5 15 15 14.5 81.520 13.5 13.5 13.5 13 13 12.5 12 7925 10 10 10 9.5 9 9 8.5 76.5
* Capacities given are for near-sea level installations.
JPF 2A, 3A, 4A, 41AProduct Guide
DWS Product Guide 8-09.indd 46 8/18/2009 2:32:50 PM
-
47
Product Guide JPF 2A, 3A, 4A, 41A
* Capacities given are for near-sea level installations.
Performance curves
DWS Product Guide 8-09.indd 47 8/18/2009 2:32:50 PM
-
48
Dimensional Drawings
Dimensions and WeightsPump Type
Motor Data D1Suction
NPT
D2Disch.NPT
D3Re-
turnNPT
Dimensions (inches) Ship Wt. (lbs)
Ship Vol. (Cu Ft.) HP S.F. PH Volts A1 A2 B B1 C1 C2 E1 E2 F G H H1 H2 H3 IØ
JPF5A 1.5 1.3 1 230 1-1/4’’ 1’’ 1’’ 22.0 15.3 8.3 11.0 8.7 2.0 13.8 7.8 0.78 5.7 10.0 6.2 4.3 2.1 0.44 70 1.9JPF7A 2 1.2 1 230 1-1/4’’ 1’’ 1’’ 25.6 19.9 8.3 12.4 8.7 2.0 13.8 7.8 0.78 5.7 10.0 6.2 4.3 2.1 0.44 73 2.5
Conversion Instructionsfrom Shallow Well to DeepWell*
Remove bolts and detach ejector nose from convertible jet pump. Connect suction (D1) and pressure (D3) port to deep well ejector.* Requires separate ejector to suit specific suction lift needs.
JPF 5A, 7A ConvertiblesProduct Guide
Shallow Well
Deep Well
DWS Product Guide 8-09.indd 48 8/18/2009 2:32:50 PM
-
49
Shallow Well Performance Chart
Model HP Depth to WaterDischarge Pressure (PSI)
Shut-off (PSI)Pressure Switch
Settings (PSI)20 30 35 40 45 50 55Capacities (U.S. gpm)*
JPF5A 1-1/2
5 21 20.5 20 20 20 19 17.5 86.5
50-7010 19 18.5 18 18 17.5 17.5 17 8415 16 16 16 15.5 15 15 14.5 81.520 13.5 13.5 13.5 13 13 12.5 12 7925 10 10 9.5 9 9 8.5 76.5
JPF7A 2
5 34 34 33.5 33 32.5 30 27 88
50-8010 28.5 28 28 28 27.5 27 26 85.715 24 24 23.5 23.5 23 22.5 22 8320 20 20 19.5 19.5 19.5 19 19 8025 15.5 15.5 15.5 15 15 15 77.8
* Capacities given are for near-sea level installations.
Performance Curves
* Capacities given are for near-sea level installations.
Product Guide JPF 5A, 7A Convertibles
DWS Product Guide 8-09.indd 49 8/18/2009 2:32:51 PM
-
50
Product Guide
Deep Well Performance Chart
Model Ejector Type Discharge Pressure (psig)
Depth to water (feet)
30 40 50 60 70 80 90 100 120 140
Capacities U.S. gpm*
JPF5A
E20
45 14.9 13.2 11.4 9.7 7.8 6.0 50 12.1 10.2 8.4 6.7 3.9 60 9.6 7.3 5.3 3.7 65 6.0 4.1 2.1 75 2.9 1.0
E25
50 10.1 8.9 8.0 6.2 4.860 8.0 6.8 5.8 4.1 3.065 6.0 5.4 1.075 5.3 3.180 2.5 1.7
E30
50 7.4 6.7 5.9 5.0 3.2 1.560 6.2 5.5 4.8 4.1 2.7 1.265 5.1 4.5 3.9 3.1 1.475 4.0 3.5 2.9 2.080 3.1 2.7 2.2 1.8
JPF7A
E20
50 17.5 15.8 14.3 11.7 8.0 5.5 1.560 14.2 12.5 10.6 8.5 6.0 3.665 11.0 9.8 7.1 5.0 2.175 7.8 6.0 3.6 1.780 4.2 2.6
E25
50 11.9 10.5 9.3 8.0 6.1 3.8 1.060 9.7 8.4 7.1 5.8 4.3 3.065 7.6 6.3 5.2 4.0 2.275 5.5 4.3 3.4 2.390 3.6 2.6 1.8
E30
65 7.9 6.9 6.1 5.1 3.9 1.575 6.3 5.6 5.1 4.3 2.8 1.080 5.3 4.6 4.1 3.5 2.090 4.3 3.7 3.2 2.6 1.295 3.3 2.9 2.4 1.9
* Capacities given are for near-sea level installations.
JPF 5A, 7A Convertibles
DWS Product Guide 8-09.indd 50 8/18/2009 2:32:51 PM
-
51
Dimensional Drawings
Dimensions and WeightsPump Type
Motor Data D1Suction
NPT
D2Disch.NPT
Dimensions (inches) Ship Wt. (lbs)
Ship Vol. (Cu Ft.) HP S.F. PH Volts A B B1 C E F G H1 H2 L IØ
JPS2A 1/2 1.6 1 115 or 230 1’’ 1’’ 14.8 7.5 9.3 3.7 4.8 7.1 4.3 9.1 7.0 0.83 0.42 24 1.5JPS4A 1 1.6 1 115 or 230 1’’ 1’’ 15.6 7.5 9.3 3.7 4.8 7.1 4.3 9.1 7.0 0.83 0.42 31 1.5
Shallow Well Performance Chart
Model HP Depth to Water
Discharge Pressure (PSI) Shut-off
(PSI)
Pressure Switch Settings (PSI)
20 30 35 40 45 50 55
Capacities (U.S. gpm)*
JPS2A 1/2
5 15 13 11 8 6 4 2 62
30-5010 14 12 10 7 5 3 1 59.515 13 11 9 6 4 2 5720 10 10 8 5 3 1 54.525 8 8 7 4 2 52
JPS4A 1
5 30 27 22 17 14 10 7 68
30-5010 26 23 21 16 13 9 6 65.515 22 21 20 15 12 8 5 6320 18 17 16 14 11 7 4 60.525 14 13 13 12 11 6 3 58
* Capacities given are for near-sea level installations.
Product Guide JPS 2A, 4A
DWS Product Guide 8-09.indd 51 8/18/2009 2:32:51 PM
-
52
* Capacities given are for near-sea level installations.
Product Guide JPS 2A, 4A
Performance curves
DWS Product Guide 8-09.indd 52 8/18/2009 2:32:51 PM
-
53
Dimensional Drawings
Dimensions and WeightsPump Type
Motor Data D1Suction
NPT
D2Disch.NPT
D3Return
NPT
Dimensions (inches) Ship Wt. (lbs)
Ship Vol. (Cu Ft.) HP S.F. PH Volts A B B1 C E IØ G H H1 H2
JDF2A 1/2 1.6 1 115 or 230 1.25’’ 1’’ 1’’ 15.2 7.1 9.1 3.5 8.0 0.38 5.5 8.9 1.9 3.6 36 1.5JDF4A 3/4 1.5 1 115 or 230 1.25’’ 1’’ 1’’ 15.2 7.1 9.1 3.5 8.0 0.38 5.5 8.9 1.9 3.6 37 1.5
Deep Well Ejector DimensionsAE HE1 HE2 X Y Z3.8 11.6 5.63 1’’ NPT 1’’NPT 1.25’’NPT
Nozzle and Venturi Combinations for Grundfos Deep Well Jet Pumps
Ejector Type Nozzle Size Venturi Sizemm. Inches mm. Inches
E20 6 0.24 12 0.48E25 6 0.24 10 0.40E30 6 0.24 8.5 0.34
Product Guide JDF 2A, 4A
Deep Well Ejector
DWS Product Guide 8-09.indd 53 8/18/2009 2:32:52 PM
-
54
Product Guide JDF 2A, 4A
Performance Chart
Model Ejector Type Discharge Pressure (psig)
Depth to water (feet)
30 40 50 60 70 80
Capacities U.S. gpm*
JDF2A
E20
20 12.0 7.0 30 4.6 35 45
SHUTOFF (psi)
E25
20 10.4 8.5 6.5 30 5.8 4.5 2.9 35 3.8 2.5 1.1 45 1.0
SHUTOFF (psi) 0.8 0.7 0.7
E30
20 8.3 7.1 6.2 4.1 3.330 5.9 4.9 4.0 2.6 1.835 4.8 3.8 2.9 1.6 45 2.9 2.0 1.3 50 2.0 1.25
SHUTOFF (psi) 1.0 0.9 0.9
JDF4A
E20
20 18 9.0 1.6 30 8.3 2.7 0.8 35 3.4 1.0 45
SHUTOFF (psi)
E25
20 13.3 11.1 8.7 30 8.7 6.8 4.8 35 6.6 4.6 2.9 45 2.6 1.0
SHUTOFF (psi) 0.8 0.8 0.7
E30
30 6.0 5.4 4.4 3.5 2.235 5.3 4.3 3.3 2.6 1.845 3.1 2.3 1.6 1.250 2.2 1.5 1.0 0.5
SHUTOFF (psi) 1.2 1.0 1.0 0.9
* Capacities given are for near-sea level installations.
DWS Product Guide 8-09.indd 54 8/18/2009 2:32:52 PM
-
55
Product Guide JPF3A Pump Package*Cast Iron Body Construction
*Available in Canada
Dimensional Drawings
Dimensions and WeightsPump Type Motor Data D1
SuctionNPT
D2Disch.NPT
Dimensions (inches) Ship Wt. (lbs)
Ship Vol. (Cu Ft.) HP S.F. PH Volts A B B1 C D E F G H1
JPF3A 1/2 1.6 1 115 or 230 1’’ 1’’ 1.2 11.9 9.1 5.5 9.1 7.1 15.2 11.9 6.0 7.0 5.0
Shallow Well Performance Chart
Model HP Depth to Water
Discharge Pressure (PSI) Shut-off
(PSI)
Pressure Switch Settings (PSI)
20 30 35 40 45 50 55
Capacities (U.S. gpm)*
JPF3A 1/2
5 12 11 11 10 7 6 4 73.5
30-5010 10.5 10 10 9.5 7 6 4 7115 9 8.5 8 8 7 6 4 68.520 7.5 7 7 7 6.5 6 4 6625 5 5 5 5 4.5 4 4 63.5
* Capacities given are for near-sea level installations.
DWS Product Guide 8-09.indd 55 8/18/2009 2:32:52 PM
-
56
Product Guide
Dimensional Drawings
Dimensions and WeightsPump Type
Motor Data D1Suction
NPT
D2Disch.NPT
Dimensions (inches) Ship Wt. (lbs)
Ship Vol. (Cu Ft.)
HP S.F. PH Volts A B B1 C E F G H1 H2 IØ
JPS2A 1/2 1.6 1 115 or 230 1’’ 1’’ 14.8 11.9 9.3 3.7 7.1 15.2 11.9 8.5 6.0 0.38 45.0 5.0
Shallow Well Performance Chart
Model HP Depth to Water
Discharge Pressure (PSI) Shut-off
(PSI)
Pressure Switch Settings (PSI)
20 30 35 40 45 50 55
Capacities (U.S. gpm)*
JPS2A 1/2
5 15 13 11 8 6 4 2 62
30-5010 14 12 10 7 5 3 1 59.515 13 11 9 6 4 2 5720 10 10 8 5 3 1 54.525 8 8 7 4 2 52
* Capacities given are for near-sea level installations.
JPS2A Pump Package*Stainless Steel Body Construction
*Available in Canada
DWS Product Guide 8-09.indd 56 8/18/2009 2:32:52 PM
-
57
Submittal data sheet
56
Company name:Prepared by:
Phone number: ( ) -Fax number: ( ) -
Submittal Data Sheet Date: Page 1 of:Quote number:
Project title: Client name:Reference number: Client number:
Client contact: Client phone no: ( ) -
For: Unit:Site: Service:
Address: City: State: Zip Code:
Technical Data Motor InformationFlow (GPM) HP:Head (Ft) Phase:Motor Voltage:Max Fluid Temp Enclosure:Min Fluid TempMax Working PressureMin Required Inlet PressureConnection Type and Size
Model Information from Type Key and Codes:Quantity Required: Example: MQ 3-35
Minimum required flow: NPSH required at duty point:Product Guide additional information pages
Materials page number: Performance curve page number:Technical data page number: Motor data page number:
Custom-built pump information (optional):
Location Information
Client Information
Additional Information
Pump Information
Submittal data sheet
DWS Product Guide 8-09.indd 57 8/18/2009 2:32:53 PM
-
Grundfos Pumps Corporation17100 W. 118th TerraceOlathe, KS 66061Telephone 913 227 3400Fax: 913 227 3500
www.grundfos.com
Grundfos Canada, Inc.2941 Brighton RoadOakville, Ontario L6H 6C9 CanadaTelephone: 905 829 9533Fax: 905 829 9512
Bombas Grundfos de Mexico, S.A. de C.V.Boulevard TLC #15Parque Stiva AeropuertoApodaca, N.L. 66600 Mexico Telephone: 52 81 8144 4000 Fax: 52 81 8144 4010
Being responsible is our foundation
Thinking ahead makes it possible
Innovation is the essence
Subject to alterations2008, 2009 Grundfos Pumps Corp.
DWS Product Guide 8-09.indd 58 8/18/2009 2:32:53 PM