Fume-A-Vent Wall-Mounted SystemDate 11/08/2012 Proposal No 12-1108-4-2 Fume-A-Vent exhaust fan can...

7
Fume-A-Vent Wall-Mounted System Date 7/12 Pa No. WM-04 Wall Mount System TAB 8-A If your garage workstations are in relative proximity to a wall, then the wall-mounted system might be a good fit for your garage. Wall-mounted systems offer a simple method for making effective use of a centralized ducting and exhausting system. With this system, each bay can be easily opened and closed with a quick sliding gate right at the duct/hose conneciton. When you need to use this system, simply unhook the hose, connect the nozzle to the tailpipe and open the gate. 1. Crushproof hose connects directly to the central duct ventilation system and is mounted at the end of a garage bay. 2. Station can be closed by a simple damper installed at the hose connection point. 3. When needed, simply remove the hose from its hanger, attach the nozzle to the vehicle, and open the damper. UME·A- I EXHAUST REMOVAL SYSTE I n, d• has bn ht a tho r of Ar Cang ists, Inc. AIR CLEANING SPECIALISTS, INC. 11088 Gravois Industrial Ct. St. Louis MO 63128 800 455-2132 Fax 636 349-0556 www.fume-a;.vent.com [email protected]

Transcript of Fume-A-Vent Wall-Mounted SystemDate 11/08/2012 Proposal No 12-1108-4-2 Fume-A-Vent exhaust fan can...

Page 1: Fume-A-Vent Wall-Mounted SystemDate 11/08/2012 Proposal No 12-1108-4-2 Fume-A-Vent exhaust fan can be installed inside or outside 12' Fume-A-Vent 2 Drop, 1 Bay Wall System 4 Inch System

Fume-A-Vent Wall-Mounted System

Date 7/12 Part No. WM-04 Wall Mount System TAB 8-A

If your garage workstations are in relative proximity to a wall, then the wall-mounted system might be a good fit for your garage. Wall-mounted systems offer a simple method for making effective use of a centralized ducting and exhausting system. With this system, each bay can be easily opened and closed with a quick sliding gate right at the duct/hose conneciton. When you need to use this system, simply unhook the hose, connect the nozzle to the tailpipe and open the gate.

1. Crushproof hose connects directly to the central duct ventilation system and ismounted at the end of a garage bay.

2. Station can be closed by a simple damper installed at the hose connection point.3. When needed, simply remove the hose from its hanger, attach the nozzle to the

vehicle, and open the damper.

S:UME·A-VE..-F I EXHAUST REMOVAL SYSTEMS I n,is d•aww'll has been copyrighted

and is tho property of

Ar Cleaning Specialists, Inc.

AIR CLEANING SPECIALISTS, INC. 11088 Gravois Industrial Ct. St. Louis MO 63128

800 455-2132 Fax 636 349-0556 www.fume-a;.vent.com [email protected]

Page 2: Fume-A-Vent Wall-Mounted SystemDate 11/08/2012 Proposal No 12-1108-4-2 Fume-A-Vent exhaust fan can be installed inside or outside 12' Fume-A-Vent 2 Drop, 1 Bay Wall System 4 Inch System

12' OVERHEAD BAY DOORS

Y-BRANCH 6",4",4"

3221-0604-104000

4" 90° ELBOW 4" - 45• ELBOW X 2 4"90° ELBOW

6" NFQF PIPE

59.25" LONG

EXTERIOR WALL

DROP1 FAN REDUCER 6"-7" DROP 2

MACHINE ADAPTOR 7.1"

1

6" STACK TO VENT

THROUGH ROOF

I-

AU',"

0

Air Cleaning Specialists Inc. 11088 Gravois Ind. Ct

St. Louis MO 63128

636-349-◄"IOO 636-349·0556 Fax

REVISIONS

SHEET NAME

DETAIL

DRAWING TITlE

WALL SYSTEM

2 DROP 1 BAY

4 INCH

OAAW<: CODY BINGAMAN

CHECKED:JIM GRAYEM

PROJECT NAME

WALL SYSTEM

DATE VIEW

11/15/12 TOP SIZE DWG NO. REV.

A 1 0

Page 3: Fume-A-Vent Wall-Mounted SystemDate 11/08/2012 Proposal No 12-1108-4-2 Fume-A-Vent exhaust fan can be installed inside or outside 12' Fume-A-Vent 2 Drop, 1 Bay Wall System 4 Inch System

Fume-A-Vent exhaus1 fan can be installed inside or outside

NO-LOSS STACK

$..'00-4«)0.100000NIE •••�.2$"'l0ol0 �10'lCOOPft ,r xS9.25" lONO

�1�1o«>00tl.80N 4'000.g. l.OC&A

IJ.-.i,---3200.(M(I0.100000Pfl£ ,-Jl��·l<WG l?oo.o«!o>-lOCOCO 0..NiaP 't.'"4 PIH • • )2«).0..00,100000IAANU,llt.kl,,STO,,.Tt •• 3'!82,0400,10000:, HOSE JiOU>TtR 4"

3:2�200000�Eet..NdP ,.

1

------12�· ____ __,

irOAUSHPAOOf H0,SE

'----------------:32'---------------'

THIS IS A CONCEPT DRAWING. ALL EQUIPMENT LOCATIONS ARE APPROXIMATE & SUBJECT TO CHANGE SHOWN WITH OPTIONAL CRUSHPROOF HOSE- SOLO SEPARATELY FAN (BLOWER) IS OPTIONAL FOR ADDITIONAL CHARGE

'OUMNT ■ llC�O,

MltQ.CN,fNO..eir.lJSll.llC

Gflft(IIW,IOR'Jf. 'lNf(lltll(IN(Da

.,._

NCtlC,.u.\MllOM�

-....ifel'fl)tllfTl.llJlll#'CN� ff'SOON\'fMtlM.�N. NC.....,"°".CCIHOOII� .. nfO'tOCIITSIOl:,,.,..U,OIII -Clll�T'OI

AIR CLEANING SPECIALISTS, INC.

Fum&-A-Vent 2 Drop, 1 Bay Wall System 4 Inch System

Date 11/0812012 Ptopoul No 12-1106-4-2

AU__ ,,11

--

0

Air Cleaning

Specialists Inc. 11088 Gravois Ind Ct. St. Louis MO 63128 636-349-◄"IOO 636-349-0556 Fax

REVISIONS

SHEET NAME

SECTION

DRAWING TITLE

WALL SYSTEM

2 DROP 1 BAY

4 INCH

OAAW'l: CODY BINGAMAN

CHECKED:JIM GRAYEM

PROJECT NAME

WALL SYSTEM

DATE 11/15/12

VIEW

SIDE

�ZE I �NO.,�-

1 IS>tm20,,

Page 4: Fume-A-Vent Wall-Mounted SystemDate 11/08/2012 Proposal No 12-1108-4-2 Fume-A-Vent exhaust fan can be installed inside or outside 12' Fume-A-Vent 2 Drop, 1 Bay Wall System 4 Inch System

AIR CLEANING SPECIALISTS, INC. 11088 Gravois Industrial Ct. St. Louis MO 63128

Quotation

COMPANY NAME: Fume-A-Vant Wall System 2 Drop, 1 Bay NFOF Quote 4 Inch System Budgetary Proposal

DELIVERY DATE: Standard Orders Ship Within 5 Days QUOTATION NUMBER: BUDGETARY PROPOSAL

REFERENCE NUMBER: 12-1108-4-2 TERMS OF DELIVERY: F.0.8 . Thomasville, NC

TERMS OF PAYMENT: Mastt..�rd, V.sa, or Alnenean l:Jl;xcss

W• :ar• �liOhtt<I to quott you tht tollowlng ducUng: LINE PCS ITEM NO DESCRIPTION

1 7 3200-0400-100000 PIPE 4• x 59.25" LONG 2 1 3200-0600-100000 PIPE 6° x 59.25" LONG 3 4 3202-0400-100000 ADJ NIPPLE WITH 0-RING 4· 4 1 3202-0600-100000 ADJ NIPPLE WITH 0-RING 6" 5 2 3210-0400-104000 ELBOW 4. OODog. 1 .OCLR 6 2 3210-0445-104000 ELBOW 4" 45Dog. 1 .OCLR 1 2 3240-0400-100000 MANUAL 8LAST GATE 4· 8 2 3282-0400-100000 HOSE ADAPTER 4• 9 20 3260-0400-100900 CLAMP WITH PIN 4·

10 4 3260-0600-100900 CLAMP WITH PIN 5·

11 1 3260-0700-100900 CLAMP WITH PIN r

12 1 3204-0600-100000 N0-1.0SS STACKHEAD 6" 13 2 3W5-0400-200000 110SE CLAMP 4· 14 1 3221-0004-104000 Y-BRANCH. A=06 8=04 0=0415 1 3222.0706-100000 11EOUCE11, A:07 8=06 16 1 3249-0600-100000 """MACHINE ADAPTOR 6.1" A=6, 8:6,11.0."" 17 1 3241M700-100000 """MACHINE A0APT01l 7 I" A•7, 8•7 1 IO •••

>7.S

, ..

•. ,

, ..

,.o

2.0

..

, ..

,.o

, ..

••

10.0 01

, ..

,.

1,1

,.

P,_ t>v C«'I o;"9"""'" 11/30/2012 9:49 AM Prices Stbjcct to Chiange Without Notice .

866 45S-2130 Fax: 636 349-0556

[email protected] www.ductingsystems.com

12-1108-4-2

DELIVERY ADDRESS:

Date: 11130112

TOTAL SALES PRICE$:

TOTAL NET SALES PRICE: All orlcn •• fOit NofOffll>. USA Wllets OChtl'Wilt noct<I

GAL.V,Of <W.V.OF

�v.or

C:W.V,O,

GAL.V. Of' GAL.V.OF

GAI.VOf

<W.V.OF

�v.or

�V.OF

GAI.V Of

GAL.V.OF

Sbf1els&ool �v. Of" (90 Oeo> GAI.V Of

�V.OF

GAI.V Of

$ $ TOTAL

25.60 179.20 33.80 33.80 15.50 62.00 16.30 16.30 46.30 92.60 39.50 79.00 42 60 6560

19.50 39.00 8.70 174.00 9.60 38.40

10 10 10 10 83.90 83.90 390 7 80

146.10 146,10 4720 4720 25.00 25.00 2690 2690

l'llge 1 ol 1 oopyright bv NORDFAB

Page 5: Fume-A-Vent Wall-Mounted SystemDate 11/08/2012 Proposal No 12-1108-4-2 Fume-A-Vent exhaust fan can be installed inside or outside 12' Fume-A-Vent 2 Drop, 1 Bay Wall System 4 Inch System

6NORDFAB'

V

-

THE WORLD1S FASTEST DUCTING

Q-F puts the squeeze on costly conventional duct Installation.

O-F is a snap! No complicated cutting, no riveting, no braising or welding are required. One O-F clampconnects sections together in seconds. Branches, diverters, elbows - all adapt easily to your existing ductand may be taken apart and re•used or cleaned without special tools.

Q-F is easy to install, easy to align, and it's strong!

O-F damps are so easy to install, they almost install themselves. Simply place the clamp overthe Q-F rolled lip ends and snap! The extraordinary strength of Q-F's specially machineddouble rolled lips provides a solid, straight run. The patented Q-F clamp connects the rolledends. Snap the O-F clamp and you have the strongest, safest, most re-usable dust-extraction piping available today. No special instructions or skills are needed to assemble a O-F system. Install new lines, clean out lines or make changes to existing duct runs anytime you need to with Q-F.

Q-F adapts to your every need; connect to the old or bring in the new.

LASER WELDED

SEAM

Q•F has everything you need in galvanized or stainless steel parts:

• LASER WELDED pipe in diameters from 3" to 24"• Branch fitting in all sizes and shapes• Elbows 30', 45°, 600, 900• Larger custom sizes and special adapters• Blast Gates, Diverter Valves, Hoods, Manifolds.

Q.f :,djusts to flt •without complicated measurements.

Planning to add, remove, or replace dust•extraction piping'? Q•F's adjustable fitting slide together to create the precise length. No need for time wasted on exact measuring and precision cuts. Simply slide on and fi to your desired length, a few inches or a few feat. Nead a different length for a new run'? Just re-use your Q-F components and re-fit again reducing your cutting and fabricating time.

Q-F saves you time and money.

Just how much money can you save using 0-F? Call usl You will be pleased with the savings and all the built-in advantages you get wtth Q-F.

Whether you need just a few parts. or help with a complete system. Q-F has 4 to 5 day lead time.

Air Cleaning Specialists Inc. 11088 Gravois Industrial Ct. St. Louis MO 63128Toll Free: 800-878-5030 Fax: 636-349-0556 www.ductingsystems.com

Call for a free sample.

6iNORDFAB'

V

Page 6: Fume-A-Vent Wall-Mounted SystemDate 11/08/2012 Proposal No 12-1108-4-2 Fume-A-Vent exhaust fan can be installed inside or outside 12' Fume-A-Vent 2 Drop, 1 Bay Wall System 4 Inch System

Fume-A-Vent Tailpipe Adapters

Date 7/12 Part No. TPA-XX Tailpipe Adapters TAB 10-A

Tailpipe adapters connect to duct using a flexable hose adapter or other hardware depending on the application. Every one of our tailpipe adapters easily connect to their intended exhaust tailpipes. We have

every kind of exhuast covered from single exhaust to diesel vertical stacks. Our tailpipe adapters can handle many different temperatues depending on the material they are made from. We have stainless steel, neoprene

rubber, and galvanized steel to fit nearty any application.

Model Tvoe F Series

DSRSeries SC

TPA03 TPA04 TPAOS TPA06

\ •

Descriotion Crushproof StraiQht Neoprene Rubber Adapters

Crushoroof Neoorene Rubber Vertical Diesel Stack Adaoter

S0�na Clam0 Option shown on F475 Adapter Rubber Encased Steel Adapter with PluQ and Clamp

Stainless Steel Ta""'red Cone Ada.oter

Rubber Coated Galvanized Steel Straight Adaplers Galvanized or Stainless Steel StraiQht Adapters

0

I

Aoolication Up lo 600° Stm19hl ltulptp0S

Vertical Exhaust Stacks Hard to adaDt Tail...,;.........,

Up to 600° Tailpipes

Hioh T ompcroturo & Diesel Exhaust StraiQht TailoiMS

thgh Temp $1JttK1hl Ta1lp1pes

S:UME-A-VENT-1� EXHAUST REMOVAL SYSTEMS I This drawing has bcoo copyrighted

and is the proporty of AIR CLEANING SPECIALISTS, INC.

11088 Gravois Industrial Ct. St. Louis MO 63128866 455-2132 Fax 636 349-0556

www.fumeavcnt.com info@fumoovcntcom

Air Cieanu111 Spec,ahsts, Inc.

Page 7: Fume-A-Vent Wall-Mounted SystemDate 11/08/2012 Proposal No 12-1108-4-2 Fume-A-Vent exhaust fan can be installed inside or outside 12' Fume-A-Vent 2 Drop, 1 Bay Wall System 4 Inch System

Fume-A-Vent Crushproof Hose

Date 7/12 Part No. Type 1 - Crushproof Hose TAB 1-A1

The Crushproof hose features a totally collapsible rubber hose with capabilities of up to 600°. This hose is so durable, it can be left on the floor and run over by any kind of vehicle or machinery including cars, trucks, and semi's. The rubber hose holds its shape after being "crushed" and will withstand much more wear, and abrasion than most other hose. Crushproof hose can accommodate tailpipes up to 8 Inches in diameter, removing harmful carcinogens from the air.

Several types of Crushproof hose are currently available, including Flarelock, Dynomater, and ACT styles. Both types are normally limited to 11' sections and can be cut to meet specific needs.

The Flarelock hose can easily be connected to additional hose or adaptors without any special connections or modifications. The ACT hose features an optional wire helix for additional support, while loosing some "crush" abilities. This hose is also available in larger sizes.

Tailpipe adaptors, connections, garage door openings, and more accessories are also available for use with Crushproof hose.

This picture above is of the Crushproof Fla relock hose with male and female ends that easily connect to additional hose or accessories.

This picture features the Crushproof ACT hose with the wire helix option for additional strength.

NOTE: The ACT with helix option cannot be used on the floor as the wire will permanently bend when run over by vehicles or machinery.

S:UME-A-VENT-1 EXHAUST REMOVAL SYSTEMS 1 ............... c--..__i.. ....

AIR CLEANING SPECIALISTS, INC. 11088 Gravois Industrial Ct. St. Louis MO 63128

866 455-2132 Fax 636 349-0556

www.ftJmeavent.com [email protected]

This drawing has been copyrighted

and is the property of

Air Cleaning Specialists, Inc •