EL-DUBAI SITE 20% 10% 10% 20%
EL-VILLA-J- 20% 10% 10% 20%
EL-DUBAI-DRIVER 20% 10% 10% 20%MEC-DUBAI SITE 20% 10% 10% 20%MECH-VILLA-J- 20% 10% 10% 20%
MECH-DUBAI-DRIVER 20% 10% 10% 20%
Items Description Material Cost QR Main Power QR Tools Cost QR Over Head QR Net Profit QR
EL-DUBAI SITE - - - - -
EL-VILLA-J- - - - - -
EL-DUBAI-DRIVER - - - - -
MEC-DUBAI SITE - - - - -
MECH-VILLA-J- - - - - -
MECH-DUBAI-DRIVER - - - - -
Total QR 0.00 0.00 0.00 0.00 0.00
EL-DUBAI SITE QR -
EL-VILLA-J- QR -
EL-DUBAI-DRIVER QR -
MEC-DUBAI SITE QR -
MECH-VILLA-J- QR -
MECH-DUBAI-DRIVER QR -
Total Amount for all MEP works QR -
Man Power Factor - MPF
Tools and Accessories Factor - TAF
Overhead Factor - OHF
Net Profit Factor - NPF
SITE WORKSELECTRICAL
MINISTRY OF FOREIGN AFFAIRS - SAUDI ARABIASTAFF HOUSING - DUBAI - UAE
ELECTRICAL BOQ
BUILDING TYPE: SITE WORKS
ITEM NO. DESCRIPTION QTY UNIT RATE TOTAL
4.00 ELECTRICAL
MAIN PANEL BOARD4.101 Supply, installation, connection and testing
main distribution board (MDB) as specified, shown in drawing and directed byEngineer in charge. The MDB shall be Floor amounted complete with copper
bus bar, adjustable MCCB's, measuring instrument, indicator Lamp. All breakers shall have breakingcapacity not less than 60KA. The price include concrete base and all required
accessories for complete installation 1 No. 0.00 0.00
DISTRIBUTOPN PANEL BOARDS4.102 Supply, installation, connection and test-
ing distribution panel boards for lighting
and power as specified shown in drawing
and directed by Engineer in charge. The
panel shall be flush mounted complete
with all bus bars and MCCB's, Residential
current device with sensitivity 30mA
shall be provide for outdoor circuits and
water heater. All branch CBS shall have
breaking capacity 10KA. The price shall
also include all chasing work and good
plaster after installation
a) DB-D Driver Room 2 No. 0.00 0.00
b) DB-GR Guard Room 2 No. 0.00 0.00
c) DB-SL Site Lightinf with Timer 1 No. 0.00 0.00
d) DB-P Pump Room 1 No. 0.00 0.00
4.103 Supply, installation,connection and testing
service circuit breaker as specified, shown
in drawing and directed by engineer in-
charge. The price include weather proof
enclosure, indicator lamp and all required
accessories for complete installation.
a) 200A, 3-Phase 380V for Fire Pump 1 No. 0.00 0.00
b) 60A, 3-Phase 380V for irrigation Pump 1 No. 0.00 0.00
SITE WORKSELECTRICAL
MINISTRY OF FOREIGN AFFAIRS - SAUDI ARABIASTAFF HOUSING - DUBAI - UAE
ELECTRICAL BOQ
c) 60A, 3-Phase 380V for water Pump 1 No. 0.00 0.00
TOTAL0.00
CARRIED OVER
SITE WORKSELECTRICAL
MINISTRY OF FOREIGN AFFAIRS - SAUDI ARABIASTAFF HOUSING - DUBAI - UAE
ELECTRICAL BOQ
BUILDING TYPE: SITE WORKS ITEM NO. DESCRIPTION QTY UNIT RATE TOTAL
4.104 Supply, installation, connection and test-
ing non-armoured multi-core cable
through heavy gauge PVC conduit
inside concrete and metallic covered
cable tray on Roof connection as
specified, shown in drawing and
directed by engineer in charge, with
insulation voltage 600/100V. The price
include all required accessories for
complete installation.
a) 3.5C-95mm2 XLPE Cable for Incoming 900 M 0.00 0.00
b)4C-25mm2 XLPE Cable for Panel 120 M 0.00 0.00
c) 4C-16mm2 XLPE Cable for Panel 30 M 0.00 0.00
d) 4C-10mm2 XLPE cable for Panel 150 M 0.00 0.00
e) 1C-70mm2 PVC Cable for Earthing 900 M 0.00 0.00
f) 1C-16mm2 PVC Cable for Earthing 150 M 0.00 0.00
g) 1C-10mm2 PVC Cable for Earthing 150 M 0.00 0.00
h) 1C-630mm2 xlpe Cable for Main supply 250 M 0.00 0.00
LIGHTING
4.105
12 No. 0.00 0.00
18 No. 0.00 0.00
TOTAL0.00
CARRIED OVER
a) Supply, installation, connection and testing recessed 50W,12v down spot light complete with transformer and all necessary accessories for complete installation. Recommended Manufacture Targitti Italy or approved equal.
b) Supply, installation, connection and testing recessed 60W, 220V parabolic incandescent down light inside concrete with all necessary accessories for complete installation. Recommended Manufacture Targitti Italy or approved equal.
SITE WORKSELECTRICAL
MINISTRY OF FOREIGN AFFAIRS - SAUDI ARABIASTAFF HOUSING - DUBAI - UAE
ELECTRICAL BOQ
BUILDING TYPE: SITE WORKS ITEM NO. DESCRIPTION QTY UNIT RATE TOTAL
16 No. 0.00 0.00
0 No. 0.00 0.00
145 No. 0.00 0.00
0 No. 0.00 0.00
12 No. 0.00 0.00
4 No.
TOTAL
0.00CARRIED OVER
c) Supply, installation, connection and testing 2x40W 220V surface mounted fluorescent lighting fixture for roof annex (IP-44) with prismatic formed duffuser as shown in drwaing as pecified. Recommended Manufacture NARDEEN Lighting or approved equal.
d) Supply, installation, connection and testing 2x40W 220V recessed fluorescent lighting fixture for kitchen (IP-44) with prismatic formed duffuser as shown in drwaing as specified. Recommended Manufacture NARDEEN Lighting or approved equal.
e) Supply, installation, connection and testing 1x70W, 220V metal helide wall mounted lighting fixture with glass cover (IP-54) for outdoor wall as shown in drwaing as specified. Manufacture NARDEEN Lighting or approved equal.
f) Supply, installation, connection and testing 1x100W, 220V incandescent pendent lighting fixture at entrance open area with glass coverl as shown in drwaing as specified. Manufacture NARDEEN Lighting or approved equal.
g) Supply, installation, connection and testing 1x250w 230V Metal Helide street pole lighting fixture on 6M Height hot dipped G.I pole complete with cables, conduits, manhole, earth electrode and all necessary accessories for complete installation (Saudi Lighting Co.)
h) Supply, installation, connection and testing 2x250w 230V Metal Helide street pole lighting fixture on 9M Height hot dipped G.I pole complete with cables, conduits, manhole, earth electrode and all necessary accessories for complete installation (Saudi Lighting Co.)
SITE WORKSELECTRICAL
MINISTRY OF FOREIGN AFFAIRS - SAUDI ARABIASTAFF HOUSING - DUBAI - UAE
ELECTRICAL BOQ
BUILDING TYPE: SITE WORKS ITEM NO. DESCRIPTION QTY UNIT RATE TOTAL
4.106 Switches Supply, installation, connection and
testing flush mounted one gang one way
single pole switch 15A, 220V as specified
shown in drawing and directed by
engineer in charge. Cover plate shall be
heavy plastic fitted with earth terminal.
Recommended product from MK or
approved equal (Matt. St. Steel) 18 No. 0.00 0.00
a) Ditto but weather proof type 4 No. 0.00 0.00
b) Ditto but for 2- gang one way 16 No. 0.00 0.00
c) Ditto but for 3- gang one way 0 No 0.00 0.00
d) Ditto but one gang two way 8 No. 0.00 0.00
e) Ditto but 2- gang 2- way 2 No. 0.00 0.00
f) Ditto but Intermediate switch 0 No. 0.00 0.00
g) Ditto but 30A, 220V Double pole
marked A/C or Hot plate with indicator lamp 8 No. 0.00 0.00
h) Ditto but 20A,220V Double pole marked
water heater or Hand dryer with indicator
lamp 5 No. 0.00 0.00
4.107 Sockets Supply, installation, connection and testing
flush mounted 20A, 220V One gang (Wp type)
socket outlet with indicator lamp. Cover
plate shall be heavy plastic fitted with
earth terminal. The price shall include the
corresponding plugs. Recommended
125 No. 0.00 0.00
a) Ditto but 30A, 220V one gang for cooker 4 No. 0.00 0.00and washing machine.
b) Ditto but 15, 220V one gang for water heater 4 No. 0.00 0.00
c) Ditto but 15, 220V one gang weather
proof type at roof A/C 8 No. 0.00 0.00
TOTAL0.00
CARRIED OVER
product from MK or approved equal (Matt. St. Steel)
SITE WORKSELECTRICAL
MINISTRY OF FOREIGN AFFAIRS - SAUDI ARABIASTAFF HOUSING - DUBAI - UAE
ELECTRICAL BOQ
BUILDING TYPE: SITE WORKS ITEM NO. DESCRIPTION QTY UNIT RATE TOTAL
4.108 Supply, installation, connection and test-
ing complete lighting, socket Aircondition
switch point with all PVC conduits, conduit
accessories and wires, starting from light-
ing, socket and Aircondition switch point to
corresponding distribution panel board
via switches.
a) Ditto but 3x4mm2 cable for lighting and
sockets 425 No. 0.00 0.00
b) Ditto but 3x6mm2 cable for Aircondition 36 No. 0.00 0.00
c) Ditto but 3x10mm2 cable cooker and Heater 16 No. 0.00 0.00
4.109
1 LS 0.00 0.00
FIRE ALARM SYSTEM
4.110
1 Set 0.00 0.00
b) Soft addressable smoke detector 12 No. 0.00 0.00
c) Soft addressable smoke detector 4 No. 0.00 0.00
d) Soft addressable manual call pont 4 No. 0.00 0.00
e) Soft addressable sounder (W.proof type) 2 No. 0.00 0.00
1 LS 0.00 0.00
TOTAL0.00
CARRIED OVER
Supply, installation, connection and testing intercom Main control control unit for 16-zone control complete with operator console, cables and conduits from Main unit to each building complete with all necessary accessories for complete installation.
a) Supply, installation connection and testing 4-loop soft addressable fire alarm control panel complete backup battery, log printer and all other necessary for complete installation.
f) Supply. Installation, connection and testing fire alarm loop from FACP to all building through under ground cable complete with conduits, cables and all other necessary accessories for complete installation
SITE WORKSELECTRICAL
MINISTRY OF FOREIGN AFFAIRS - SAUDI ARABIASTAFF HOUSING - DUBAI - UAE
ELECTRICAL BOQ
BUILDING TYPE: SITE WORKS ITEM NO. DESCRIPTION QTY UNIT RATE TOTAL
Telephone System4.111 a) Supply, installation, connection and test-
ing main distribution frame (MDF)
200 pairs each as specified, shown in
drawing and directed by engineer
in charge. The price include all
necessary accessories for complete
installation 1 No 0.00 0.00
b) Supply, installation, connection and test-
ing Telephone Terminal Box (TTB)
10 pairs each as specified, shown in
drawing and directed by engineer
in charge. The price include all
necessary accessories for complete
installation 4 No 0.00 0.00
c) Supply, installation, connection and test-
ing flush mounted telephone socket, line
jack 'RJ11' type as specified, shown in
drawing and directed by engineer
in charge. The cover plate shall be heavy
plastic fitted with earth terminal. The price
include the corresponding plug 12 No. 0.00 0.00
d) Supply, installation, connection and test-
ing telephone points with all PVC
conduits. conduit accessories and 2 pair
0.6mm telephone cable starting form tele-
phone outlet point to MDF or IDF in the
same floor. The price include also chasing
making good plaster and any required
accessories for complete installation. 12 No. 0.00 0.00
e) Supply, installation, connection and test-
ing 20 pair telephone cable form TTB to
MDF as shown in drawing and directed by
Engineer. The price include PVC conduits
accessories and any required material
for complete installation 900 M 0.00 0.00
TOTAL0.00
CARRIED OVER
SITE WORKSELECTRICAL
MINISTRY OF FOREIGN AFFAIRS - SAUDI ARABIASTAFF HOUSING - DUBAI - UAE
ELECTRICAL BOQ
BUILDING TYPE: SITE WORKS ITEM NO. DESCRIPTION QTY UNIT RATE TOTAL
DIGITAL SATELLITE ANTENNA SYSTEM4.112
2 L.S 0.00 0.00
b) Supply, installation, connection and test-
ing antenna socket for minimum dB losses
type as specified to verify the indicated
signal level. The price shall also include
the end of line resistor(75 Ohm) for each
socket and any required accessories for
complete installation 6 No. 0.00 0.00
c)Supply, installation, connection and
testing main central Antenna system net-
work through the building complete with
conduits, RG11 and RG6 coaxial cables,
minimum dB losses splitters. tap-off and
amplifier as shown in drawing. The price
shall include any required accessories
for complete installation. 1 L.S 0.00 0.00
Earthing System4.113 Supply, installation, connection and testing
MDB Earthing system as specified
shown in drawing and directed by eng-
neer in charge. The price include Loop
conductor, Earth Electrode, Inspection Pit
excavation, backfilling and all other
necessary accessories for complete
installation. 1 L.S 0.00 0.00
TOTAL0.00
CARRIED OVER
a)Supply, installation, connection and testing digital receiver antenna system complete with dishes, 3nos. 4-ouput LNB, diseq switch as shown on drawing complete with all necessary accessories for complete installation.
SITE WORKSELECTRICAL
MINISTRY OF FOREIGN AFFAIRS - SAUDI ARABIASTAFF HOUSING - DUBAI - UAE
ELECTRICAL BOQ
BUILDING TYPE: SITE WORKS ITEM NO. DESCRIPTION QTY UNIT RATE TOTAL
Page 1 0.00
Page 2 0.00
Page 3 0.00
Page 4 0.00
Page 5 0.00
Page 6 0.00
Page 7 0.00
TOTAL0.00
CARRIED OVER
EL-VILLA-J-
Page 11
BUILDING TYPE: VILLA "J"
ITEM NO. DESCRIPTION QTY UNIT RATE TOTAL
4.00 ELECTRICAL
MAIN PANEL BOARD4.101 Supply, installation, connection and testing
main distribution board (MDB) as specified, shown in drawing and directed byEngineer in charge. The MDB shall be Floor amounted complete with copper
bus bar, adjustable MCCB's, measuring instrument, indicator Lamp. All breakers shall have breakingcapacity not less than 60KA. The price include concrete base and all required
accessories for complete installation 2 No. 0.00 0.00
DISTRIBUTOPN PANEL BOARDS4.102 Supply, installation, connection and test-
ing distribution panel boards for lighting and power as specified shown in drawing
and directed by Engineer in charge. The panel shall be flush mounted complete
with all bus bars and MCCB's, Residential current device with sensitivity 30mA shall be provide for outdoor circuits andwater heater. All branch CBS shall have breaking capacity 10KA. The price shall also include all chasing work and good plaster after installation
a) DB-G Ground Floor 2 No. 0.00 0.00
b) DB-F First Floor 2 No. 0.00 0.00
c) DB-R Roof 2 No. 0.00 0.00
d) DB-AC Roof 2 No. 0.00 0.00
4.103 Supply, installation,connection and testingservice circuit breaker as specified, shownin drawing and directed by engineer in-charge. The price include weather proofenclosure, indicator lamp and all requiredaccessories for complete installation.
a)50A, 220V, 1 Phase-60Hz for A/C Unit at Roof. 28 No. 0.00 0.00
TOTAL0.00
CARRIED OVER
EL-VILLA-J-
Page 12
BUILDING TYPE: VILLA "J"ITEM NO. DESCRIPTION QTY UNIT RATE TOTAL
4.104 Supply, installation, connection and test-
ing non-armoured multi-core cable
through heavy gauge PVC conduit inside concrete and metallic covered cable tray on Roof connection asspecified, shown in drawing and directed by engineer in charge, with
insulation voltage 600/100V. The price include all required accessories for
complete installation.
a) 3.5C-95mm2 XLPE Cable for Incoming 0 M 0.00 0.00
b)4C-35mm2 XLPE Cable for Panel 120 M 0.00 0.00
c) 4C-16mm2 XLPE Cable for Panel 480 M 0.00 0.00
d) 4C-10mm2 XLPE cable for Panel 300 M 0.00 0.00
e) 1C-70mm2 PVC Cable for Earthing 0 M 0.00 0.00
f) 1C-16mm2 PVC Cable for Earthing 480 M 0.00 0.00
g) 1C-10mm2 PVC Cable for Earthing 300 M 0.00 0.00
LIGHTING4.105
300 No. 0.00 0.00
24 No. 0.00 0.00
TOTAL0.00
CARRIED OVER
a) Supply, installation, connection and testing recessed 50W,12v down spot light complete with transformer and all necessary accessories for complete installation. Recommended Manufacture Targitti Italy or approved equal.
b) Supply, installation, connection and testing recessed 60W, 220V parabolic incandescent down light inside concrete with all necessary accessories for complete installation. Recommended Manufacture Targitti Italy or approved equal.
EL-VILLA-J-
Page 13
BUILDING TYPE: VILLA "J"ITEM NO. DESCRIPTION QTY UNIT RATE TOTAL
8 No. 0.00 0.00
8 No. 0.00 0.00
24 No. 0.00 0.00
20 No. 0.00 0.00
8 No. 0.00 0.00
8 No. 0.00 0.00
8 No. 0.00 0.00
12 No. 0.00 0.00
TOTAL0.00
CARRIED OVER
c) Supply, installation, connection and testing 2x40W 220V surface mounted fluorescent lighting fixture for roof annex (IP-44) with prismatic formed duffuser as shown in drwaing as pecified. Recommended Manufacture NARDEEN Lighting or approved equal.
d) Supply, installation, connection and testing 2x40W 220V recessed fluorescent lighting fixture for kitchen (IP-44) with prismatic formed duffuser as shown in drwaing as specified. Recommended Manufacture NARDEEN Lighting or approved equal.
e) Supply, installation, connection and testing 2x40W 220V wall mounted incandescent lighting fixture with fancy glass cover for indoor wall as shown in drwaing as specified.
f) Supply, installation, connection and testing 1x70W, 220V metal helide wall mounted lighting fixture with glass cover (IP-54) for outdoor wall as shown in drwaing as specified. Manufacture NARDEEN Lighting or approved equal.
g) Supply, installation, connection and testing 1x100W, 220V incandescent pendent lighting fixture at entrance open area with glass coverl as shown in drwaing as specified. Manufacture NARDEEN Lighting or approved equal.
h) Supply, installation, connection and testing 3x40W, 220V incandescent pendent chandelier with fancy glass coverl as shown in drwaing as specified manyfacturered in Austria .
i) Supply, installation, connection and testing 25x30W, 220V incandescent pendent chandelier with fancy glass coverl as shown in drwaing as specified manyfacturered in Austria .
j) Supply, installation, connection and testing 2x30W, 220V incandescent mirror lightr with fancy glass coverl as shown in drwaing as specified.
EL-VILLA-J-
Page 14
BUILDING TYPE: VILLA "J"ITEM NO. DESCRIPTION QTY UNIT RATE TOTAL
4.106 Switches Supply, installation, connection and
testing flush mounted one gang one waysingle pole switch 15A, 220V as specified shown in drawing and directed byengineer in charge. Cover plate shall beheavy plastic fitted with earth terminal.
48 No. 0.00 0.00
a) Ditto but weather proof type 32 No. 0.00 0.00
b) Ditto but for 2- gang one way 24 No. 0.00 0.00
c) Ditto but for 3- gang one way 2 No 0.00 0.00
d) Ditto but one gang two way 32 No. 0.00 0.00
e) Ditto but 2- gang 2- way 20 No. 0.00 0.00
f) Ditto but Intermediate switch 4 No. 0.00 0.00
g) Ditto but 30A, 220V Double pole
marked A/C or Hot plate with indicator lamp 32 No. 0.00 0.00
g) Ditto but 20A,220V Double pole marked water heater or Hand dryer with indicator lamp 20 No. 0.00 0.00
4.107 Sockets Supply, installation, connection and
testing flush mounted 20A, 220V One gang
socket outlet with indicator lamp. Coverplate shall be heavy plastic fitted with earth terminal. The price shall include thecorresponding plugs. Recommended
product from MK matt Sy. Steel or approved equal. 156 No. 0.00 0.00
a) Ditto but 30A, 220V one gang for cooker 4 No. 0.00 0.00and washing machine.
b) Ditto but 15, 220V one gang for water heater 20 No. 0.00 0.00
c) Ditto but 15, 220V one gang weather
proof type at roof 20 No. 0.00 0.00
TOTAL0.00
CARRIED OVER
Recommended product from MK (matt St. Steel) or approved equal
EL-VILLA-J-
Page 15
BUILDING TYPE: VILLA "J"ITEM NO. DESCRIPTION QTY UNIT RATE TOTAL
4.108 Supply, installation, connection and test-ing complete lighting, socket Airconditionswitch point with all PVC conduits, conduitaccessories and wires, starting from light-ing, socket and Aircondition switch point tocorresponding distribution panel board via switches.
a) Ditto but 3x4mm2 cable for lighting andsockets 700 No. 0.00 0.00
b) Ditto but 3x6mm2 cable for Aircondition 32 No. 0.00 0.00
c) Ditto but 3x10mm2 cable cooker and Heater 32 No. 0.00 0.00
4.109 Supply, installation, connection and testing Door intercom receiving unit asspecified, shown in drawing and directedby engineer in charge. The price includepush button station and receiving station andall required accessories for completeinstallation. 2 Set 0.00 0.00
FIRE ALARM SYSTEM4.110 Supply, installation connection and
testing analog soft addressable, optical smoke detector equipped with
indicator lamp and built in isolator as specified, shown in drawing and
directed by engineer in charge. The
detector shall consists of three parts: Terminal plates, Electronic Module and Sensing element 30 No. 0.00 0.00
a) Ditto but for analogue soft addressableFixed heat detector 4 No. 0.00 0.00
b) Supply, installation connection andtesting manual call point as specified shown in drawing and directed byengineer in charge. 8 No. 0.00 0.00
c) Supply, installation connection andtesting Electronic sounder, the output shall be100dB as specified, shown in draw-ing and directed by engineer in charge 8 No. 0.00 0.00
TOTAL0.00
CARRIED OVER
EL-VILLA-J-
Page 16
BUILDING TYPE: VILLA "J"ITEM NO. DESCRIPTION QTY UNIT RATE TOTAL
d)Supply, installation, connection and test-ing the fire alarm loops as specified, shown in drawing and directed by engin-eer in charge with all PVC conduits,conduit accessories and fire resistancewires (The size will be as per manufac-turner recommendation). The price shallinclude also chasing making good plaster and required material for complete installation. 2 LS 0.00 0.00
Telephone System4.111 a) Supply, installation, connection and test-
ing Telephone Terminal Box (TTB)
20 pairs each as specified, shown in drawing and directed by engineer
in charge. The price include all necessary accessories for completeinstallation 2 No 0.00 0.00
b) Supply, installation, connection and test-ing flush mounted telephone socket, linejack 'RJ11' type as specified, shown in drawing and directed by engineer
in charge. The cover plate shall be heavy plastic fitted with earth terminal. The price
include the corresponding plug 36 No. 0.00 0.00 c) Supply, installation, connection and test- ing telephone points with all PVC
conduits. conduit accessories and 2 pair0.6mm telephone cable starting form tele-phone outlet point to MDF or IDF in thesame floor. The price include also chasingmaking good plaster and any required
accessories for complete installation. 36 No. 0.00 0.00
d) Supply, installation, connection and test-ing 20 pair telephone cable form TTB toMDF as shown in drawing and directed by Engineer. The price include PVC conduits accessories and any required materialfor complete installation 0 M 0.00 0.00
TOTAL0.00
CARRIED OVER
EL-VILLA-J-
Page 17
BUILDING TYPE: VILLA "J"ITEM NO. DESCRIPTION QTY UNIT RATE TOTAL
DIGITAL SATELLITE ANTENNA SYSTEM
4.112
2 L.S 0.00 0.00
a) Supply, installation, connection and test-ing antenna socket for minimum dB losses
type as specified to verify the indicated signal level. The price shall also include
the end of line resistor(75 Ohm) for eachsocket and any required accessories forcomplete installation 20 No. 0.00 0.00
b)Supply, installation, connection andtesting main central Antenna system net-
work through the building complete with conduits, RG11 and RG6 coaxial cables,
minimum dB losses splitters. tap-off andamplifier as shown in drawing. The priceshall include any required accessoriesfor complete installation. 2 L.S 0.00 0.00
Earthing System4.113 Supply, installation, connection and testing
Panel Board Earthing system as specifiedshown in drawing and directed by eng-neer in charge. The price include Loop conductor, Earth Electrode, Inspection Pitexcavation, backfilling and all other necessary accessories for complete installation. 2 L.S 0.00 0.00
TOTAL0.00
CARRIED OVER
Supply, installation, connection and testing digital receiver antenna system complete with dishes, 3nos. 4-ouput LNB, diseq switch as shown on drawing complete with all necessary accessories for complete installation.
EL-VILLA-J-
Page 18
BUILDING TYPE: VILLA "J"ITEM NO. DESCRIPTION QTY UNIT RATE TOTAL
Page 1 0.00
Page 2 0.00
Page 3 0.00
Page 4 0.00
Page 5 0.00
Page 6 0.00
Page 7 0.00
TOTAL0.00
CARRIED OVER
EL-DUBAI-DRIVER
Page 19
BUILDING TYPE: DRIVERS' ANNEXS
ITEM NO. DESCRIPTION QTY UNIT RATE TOTAL
4.00 ELECTRICAL
DISTRIBUTOPN PANEL BOARDS4.101 Supply, installation, connection and test-
ing distribution panel boards for lighting and power as specified shown in drawing
and directed by Engineer in charge. The panel shall be flush mounted complete
with all bus bars and MCCB's, Residential current device with sensitivity 30mA shall be provide for outdoor circuits andwater heater. All branch CBS shall have breaking capacity 10KA. The price shall also include all chasing work and good plaster after installation
a) DB-G1 AND G2 2 No. 0.00 0.00
4.102 Supply, installation,connection and testingservice circuit breaker as specified, shownin drawing and directed by engineer in-charge. The price include weather proofenclosure, indicator lamp and all requiredaccessories for complete installation.
a)30A, 220V, 1 Phase-60Hz for A/C Unit at Roof. 6 No. 0.00 0.00
4.104 Supply, installation, connection and test- ing non-armoured multi-core cable through heavy gauge PVC conduit inside concrete and metallic covered cable tray on Roof connection asspecified, shown in drawing and directed by engineer in charge, with insulation voltage 600/100V. The price
include all required accessories forcomplete installation.
a) 3.5C-25mm2 XLPE Cable 175 M 0.00 0.00
TOTAL0.00
EL-DUBAI-DRIVER
Page 20
CARRIED OVER0.00
EL-DUBAI-DRIVER
Page 21
BUILDING TYPE: DRIVERS' ANNEXSITEM NO. DESCRIPTION QTY UNIT RATE TOTAL
4.105 LIGHTING
10 No. 0.00 0.00
12 No. 0.00 0.00
10 No. 0.00 0.00
4 No. 0.00 0.00
4.106 Switches Supply, installation, connection and
testing flush mounted one gang one waysingle pole switch 15A, 220V as specified shown in drawing and directed byengineer in charge. Cover plate shall beheavy plastic fitted with earth terminal.Recommended product from MK or approved equal 6 No. 0.00 0.00
a) Ditto but weather proof type 4 No. 0.00 0.00
b) Ditto but for 2- gang one way 4 No. 0.00 0.00
c) Ditto but 30A, 220V Double pole marked A/C or Hot plate with indicator lamp 8 No. 0.00 0.00
d) Ditto but 20A,220V Double pole marked water heater or Hand dryer with indicator lamp 4 No. 0.00 0.00
TOTAL0.00
CARRIED OVER
a) Supply, installation, connection and testing recessed 60W, 220V parabolic incandescent down light inside concrete with all necessary accessories for complete installation. Recommended Manufacture Zumtobell Staff or approved equal.
b) Supply, installation, connection and testing 2x40W 220V surface mounted fluorescent lighting fixture for roof annex (IP-44) with prismatic formed duffuser as shown in drwaing as pecified. Recommended Manufacture NARDEEN Lighting or approved equal.
c) Supply, installation, connection and testing 1x70W, 220V metal helide wall mounted lighting fixture with glass cover (IP-54) for outdoor wall as shown in drwaing as specified. Manufacture NARDEEN Lighting or approved equal.
d) Supply, installation, connection and testing 1x100W, 220V incandescent pendent lighting fixture at entrance open area with glass coverl as shown in drwaing as specified. Manufacture NARDEEN Lighting or approved equal.
EL-DUBAI-DRIVER
Page 22
BUILDING TYPE: DRIVERS' ANNEXSITEM NO. DESCRIPTION QTY UNIT RATE TOTAL
4.107 Sockets Supply, installation, connection and
testing flush mounted 20A, 220V One gang socket outlet with indicator lamp. Coverplate shall be heavy plastic fitted with earth terminal. The price shall include thecorresponding plugs. Recommended product from MK or approved equal. 12 No. 0.00 0.00
a) Ditto but 30A, 220V one gang for cooker 2 No. 0.00 0.00and washing machine.
b) Ditto but 15, 220V one gang for water heater 2 No. 0.00 0.00
4.108 Supply, installation, connection and test-ing complete lighting, socket Airconditionswitch point with all PVC conduits, conduitaccessories and wires, starting from light-ing, socket and Aircondition switch point tocorresponding distribution panel board via switches.
a) Ditto but 3x4mm2 cable for lighting andsockets 80 No. 0.00 0.00
b) Ditto but 3x6mm2 cable for Aircondition 20 No. 0.00 0.00
c) Ditto but 3x10mm2 cable cooker and Heater 4 No. 0.00 0.00
FIRE ALARM SYSTEM4.110 Supply, installation connection and
testing analog soft addressable, optical smoke detector equipped with indicator lamp and built in isolator as
specified, shown in drawing and directed by engineer in charge. The detector shall consists of three parts:
Terminal plates, Electronic Module and Sensing element 8 No. 0.00 0.00
a) Ditto but for analogue soft addressableFixed heat detector 2 No. 0.00 0.00
b) Supply, installation connection andtesting manual call point as specified shown in drawing and directed byengineer in charge. 2 No. 0.00 0.00
TOTAL0.00
CARRIED OVER
EL-DUBAI-DRIVER
Page 23
BUILDING TYPE: DRIVERS' ANNEXSITEM NO. DESCRIPTION QTY UNIT RATE TOTAL
c) Supply, installation connection andtesting Electronic sounder, the output shall be100dB as specified, shown in draw-ing and directed by engineer in charge 2 No. 0.00 0.00
d)Supply, installation, connection and test-ing the fire alarm loops as specified, shown in drawing and directed by engin-eer in charge with all PVC conduits,conduit accessories and fire resistancewires (The size will be as per manufac-turner recommendation). The price shallinclude also chasing making good plaster and required material for complete installation. 1 LS 0.00 0.00
Telephone System4.111 a) Supply, installation, connection and test-
ing Telephone Terminal Box (TTB) 10 pairs each as specified, shown in
drawing and directed by engineerin charge. The price include all necessary accessories for completeinstallation 2 No 0.00 0.00
b) Supply, installation, connection and test-ing flush mounted telephone socket, linejack 'RJ11' type as specified, shown in drawing and directed by engineer in charge. The cover plate shall be heavy
plastic fitted with earth terminal. The price include the corresponding plug 4 No. 0.00 0.00
c) Supply, installation, connection and test- ing telephone points with all PVC
conduits. conduit accessories and 2 pair0.6mm telephone cable starting form tele-phone outlet point to MDF or IDF in thesame floor. The price include also chasingmaking good plaster and any required accessories for complete installation. 4 No. 0.00 0.00
TOTAL0.00
CARRIED OVER
EL-DUBAI-DRIVER
Page 24
BUILDING TYPE: DRIVERS' ANNEXSITEM NO. DESCRIPTION QTY UNIT RATE TOTAL
d) Supply, installation, connection and test-ing 5 pair telephone cable form TTB toMDF as shown in drawing and directed by Engineer. The price include PVC conduits accessories and any required materialfor complete installation 150 M 0.00 0.00
DIGITAL SATELLITE ANTENNA SYSTEM
4.112 2 L.S 0.00 0.00
a) Supply, installation, connection and test-ing antenna socket for minimum dB losses type as specified to verify the indicated
signal level. The price shall also includethe end of line resistor(75 Ohm) for eachsocket and any required accessories forcomplete installation 2 No. 0.00 0.00
b)Supply, installation, connection andtesting main central Antenna system net- work through the building complete with
conduits, RG11 and RG6 coaxial cables,minimum dB losses splitters. tap-off andamplifier as shown in drawing. The priceshall include any required accessoriesfor complete installation. 1 L.S 0.00 0.00
TOTAL0.00
CARRIED OVER
Supply, installation, connection and testing digital receiver antenna system complete with dishes, 3nos. 4-ouput LNB, diseq switch as shown on drawing complete with all necessary accessories for complete installation.
EL-DUBAI-DRIVER
Page 25
BUILDING TYPE: DRIVERS' ANNEXSITEM NO. DESCRIPTION QTY UNIT RATE TOTAL
Page 1 0.00
Page 2 0.00
Page 3 0.00
Page 4 0.00
Page 5 0.00
TOTAL0.00
CARRIED OVER
MEC-DUBAI SITE
Page 26
BUILDING TYPE :SITE WORKS (DUBAI-MECHANICAL)
ITEM No DESCRIPTION QTY UNIT RATE TOTAL
3.0.0 MECHANICAL
3.1.0 HEATING, VENTILATION AND AIRCONDITION SYSTEM(BRAND CARRIER)
3.1.1 Supply and installation of roof mounted Condensing Unitas specified, shown in drawing and directed by Engineerin charge. The price include with Evaporator, Compressorexpansion valve, factory pipe and supply with all control,
accessories for complete inatallation (BRAND CARRIER)
a) Condensing Unit GR-1 2 No 0.00 0.00
b) Condensing Unit DR-1 2 No 0.00 0.00
3.1.2 Supply and installation of concealled air handling Unitas specified, shown in drawing and directed by Engineerin charge. The price include with all duct work,flexibleconnection, Volume control, dampers and all other necessary accessories for complete installation. a) Air handling Unit GR-1 2 No 0.00 0.00
b) Air handling Unit DR-1 2 No 0.00 0.00
3.1.3 Supply, nstallation , connection and testing Centrifugalwall mounted exhaust fan as specified, shown in drawingand directed by Engineer. The price included all necessary
accessories for complete installation.
DR-1 4 No 0.00 0.00
GR-1 2 No 0.00 0.00
3.1.4 Supply and installation of Grilles and diffusers as shown on drawing and as specified. 1 L.S 0.00 0.00
3.1.5 Testing and commissioning of the HVAC system. 1 L.S 0.00 0.00
Heater enclosed in steel enclosure and all other necessary.
MEC-DUBAI SITE
Page 27
TOTAL0.00
CARRIED OVER
MEC-DUBAI SITE
Page 28
BUILDING TYPE :SITE WORKS (DUBAI-MECHANICAL)ITEM No DESCRIPTION QTY UNIT RATE TOTAL
3.2.0 PLUMPING SYSTEM
3.2.1 Supply and installation of water closet westerntype complete with all trims, Cistern, angle value,Flexible steinless steel Hose, perivleal hose and
6 No 0.00 0.00
3.2.2 Supply and installation of bidet complete wih mixer unitfexible pipes, angle stops, valve, escuchion plates as shown in drawing and direced Engineer. The price include
0 No 0.00 0.00
3.2.3 Supply and installation of counter top lavatory complete with mixing valve, spout, pop-up waste,P-trap, angle values, flexible hose as shown on drawing and as specified (American Standard) 4 No 0.00 0.00
3.2.4 Supply and installation of wall hang lavatory complete with mixing value, spout, pop-up waste,P-trap, angle valves, flexible hose,as shown on drawing and as specified (American Standard) 2 No 0.00 0.00
3.2.5 Supply and installation of shower tray complete with waste - trap, and showe head as shown on drawing and as specified (American Standard) 4 No 0.00 0.00
3.2.6 Supply and installation of Bath tub complete withdrain, brain trap, showes head, mixing value,
0 No 0.00 0.00
3.2.7 Supply and installation of kitchen Sink stainless steelwith double bowl and drain board and trims. 4 No 0.00 0.00
3.2.8 1 L.S. 0.00 0.00
3.2.9 Supply and installation of elastomeric- rubberinsulation 6mm. thick for hot water supply pipe. 1 L.S. 0.00 0.00
3.2.9.A
a) 75 dia upvc class-5 325 M 0.00 0.00
b) 63dia upvc class-5 160 M 0.00 0.00
c)25dia upvc class-5 225 M 0.00 0.00
TOTAL0.00
CARRIED OVER
value as shown on drawing and as specified (American Standard)
all necessary accessories for complete installation (American Standard)
spout, etc. as shown on drawing and as specified (American Standard)
Supply and installation of cpvc Class-5 pipe for cold and hot water at driver and guard room toilet and kitchen complete with all fittings.
Supply and installation of Upvc Class-5 under ground pipe for cold water supply to all villas, guard room and driver room. The price included excavation, backfilling and all necessary fitting for complete installation.
MEC-DUBAI SITE
Page 29
BUILDING TYPE :SITE WORKS (DUBAI-MECHANICAL)ITEM No DESCRIPTION QTY UNIT RATE TOTAL
3.2.10 1 L.S. 0.00 0.00
3.2.11 Supply, installation, connection and testing of water heater shown in drawing and directed by Engineer in
ture valve, connection through pipe to drain and all nece-ssary accessories for complete installation. 4 No 0.00 0.00
3.2.12 Supply and installation of isolating valve as specified and shown in drawing.
63mm Dia50mm Dia40mm Dia 1 L.S 0.00 0.0032mm Dia25mm Dia
3.1.13
110mm Dia75mm Dia65mm Dia 1 L.S 0.00 0.0050mm Dia40mm Dia
i) 163 dia upvc class-4 325 M 0.00 0.00
ii) 110dia upvc class-4 160 M 0.00 0.00
3.2.14 Supply and installation of Cast iron roof pipe drain as specified and shown in drawing
100mm Dia 1 L.S 0.00 0.00
3.2.15 Supply and installation of cast iron roof drain as specified and shown in drawing 6 No 0.00 0.00
3.2.16 Supply and installation of floor cleanout drain as 6 No 0.00 0.00 specified and shown in drawing
TOTAL0.00
CARRIED OVER
Connect to the external system complete with water meter, tanker water fill points etc.
charge. The price include isolation valve,
a)Supply and installation of UPVC class-4 darinage pipe for driver room and guard room toilet and kitchen complete with all fittings.
b))Supply and installation of UPVC class-4 under ground darinage pipe for all villa, driver room and guard room complete with all fittings, manholes.
MEC-DUBAI SITE
Page 30
BUILDING TYPE :SITE WORKS (DUBAI-MECHANICAL)ITEM No DESCRIPTION QTY UNIT RATE TOTAL
3.2.17 Supply and installation of floor drain as specified and shown in drawing 8 No 0.00 0.00
3.2.18 1 Set 0.00 0.00
3.3.0 IRRIGATION SYSTEM
1 L.S 0.00 0.00
1 Set 0.00 0.00
3.4.0 FIRE FIGHTING SYSTEM
a) 163 dia upvc class-4 35 M 0.00 0.00
b) 110dia upvc class-4 300 M 0.00 0.00
c) Fire Hose cabinet complete with 30M hose reel 6 No 0.00 0.00
1 Set 0.00 0.00
TOTAL0.00
CARRIED OVER
Supply an installation of water pump set ( 1-running and 1-stand by) 70GPM 60M Head as shown in and as specified complete with all fitting and meter gauge for complete installation.
a)Supply, installation, connection and testing under ground piping upvc-class-5 as required by green area complete with sprinklers, bablers, control valves, gate valves, irrigation control panel, electrical wiring complete with all necessary accessories for complete instsllation.
b)Supply an installation of irrigation pump set ( 1-running and 1-stand by) 100GPM 80M Head as shown in drawing and as specified complete with all fitting and meter gauge for complete installation.
Supply and installation of UPVC class-5 under ground fighting pipe for all fire hose cabinet complete with all fittings, manholes as required and as shown on drawing.
d)Supply an installation of fire pump set ( 1-running and 1-stand by), jocky pump 250GPM 60M Head as shown in drawing and as specified complete with all fitting and meter gauge for complete installation.
MEC-DUBAI SITE
Page 31
BUILDING TYPE :SITE WORKS (DUBAI-MECHANICAL)ITEM No DESCRIPTION QTY UNIT RATE TOTAL
Page 1 0.00
Page 2 0.00
Page 3 0.00
Page 4 0.00
TOTAL0.00
CARRIED OVER
MECH-VILLA-J-
Page 32
BUILDING TYPE :VILLA "J"
DESCRIPTION QTY UNIT RATE TOTAL
3.0.0 MECHANICAL
3.1.0 HEATING, VENTILATION AND AIRCONDITION SYSTEM
3.1.1 Supply and installation of roof mounted Condensing Unitas specified, shown in drawing and directed by Engineerin charge. The price include with Evaporator, Compressorexpansion valve, factory pipe and supply with all control,Heater enclosed in steel enclosure and all other necessary.accessories for complete inatallation.(CARRIER)
a) Condensing Unit GF-1 1 No 0.00 0.00
b) Condensing Unit GF-2 1 No 0.00 0.00
c) Condensing Unit GF-3 1 No 0.00 0.00
d) Condensing Unit GF-4 1 No 0.00 0.00
e) Condensing Unit FF-5 1 No 0.00 0.00
f) Condensing Unit FF-6 1 No 0.00 0.00
g) Condensing Unit FF-7 1 No 0.00 0.00
h) Condensing Unit FF-8 1 No 0.00 0.00
i) Condensing Unit FF-9 1 No 0.00 0.00
j) Condensing Unit PH-11 1 No 0.00 0.00
k) Condensing Unit PH-12 1 No 0.00 0.00
l) Condensing Unit RF-13 1 No 0.00 0.00
3.1.2 Supply and installation of concealled air handling Unitas specified, shown in drawing and directed by Engineerin charge. The price include with all duct work,flexibleconnection, Volume control, dampers and all other necessary accessories for complete installation(CARRIER) a) Air handling Unit GF-1 1 No 0.00 0.00
b) Air handling Unit GF-2 1 No 0.00 0.00
c) Air handling Unit GF-3 1 No 0.00 0.00
d) Air handling Unit GF-4 1 No 0.00 0.00
e) Air handling Unit FF-5 1 No 0.00 0.00
TOTAL0.00
CARRIED OVER
ITEM No
MECH-VILLA-J-
Page 33
BUILDING TYPE :VILLA "J"
DESCRIPTION QTY UNIT RATE TOTAL
f) Air handling Unit FF-6 1 No 0.00 0.00
g) Air handling Unit FF-7 1 No 0.00 0.00
h) Air handling Unit FF-8 1 No 0.00 0.00
i)Air handling Unit FF-9 1 No 0.00 0.00
j)Air handling Unit PH-11 1 No 0.00 0.00
k) Air handling Unit PH-12 1 No 0.00 0.00
l) Air handling Unit RF-13 1 No 0.00 0.00
3.1.3 Supply, nstallation , connection and testing Centrifugalwall mounted exhaust fan as specified, shown in drawingand directed by Engineer. The price included all necessaryaccessories for complete installation(BROAN Co. USA)
GF-1 1 No 0.00 0.00
GF-2 1 No 0.00 0.00
GF-3 1 No 0.00 0.00
FF-1 1 No 0.00 0.00
FF-2 1 No 0.00 0.00
FF-3 1 No 0.00 0.00
FF-4 1 No 0.00 0.00
RF-1 1 No 0.00 0.00
3.1.4 Supply and installation of Grilles and diffusers as shown on drawing and as specified. 1 L.S 0.00 0.00
3.1.5 Testing and commissioning of the HVAC system. 1 L.S 0.00 0.00
3.2.0 PLUMPING SYSTEM
3.2.1 Supply and installation of water closet westerntype complete with all trims, Cistern, angle value,Flexible steinless steel Hose, perivleal hose andvalue as shown on drawing and as specified (American Standard) 6 No 0.00 0.00
3.2.2 Supply and installation of bidet complete wih mixer unitfexible pipes, angle stops, valve, escuchion plates as shown in drawing and direced Engineer. The price includeall necessary accessories for complete installation(American Standard) 6 No 0.00 0.00
TOTAL0.00
CARRIED OVER
ITEM No
MECH-VILLA-J-
Page 34
BUILDING TYPE :VILLA "J"ITEM No DESCRIPTION QTY UNIT RATE TOTAL
3.2.3 Supply and installation of counter top lavatory complete with mixing valve, spout, pop-up waste,P-trap, angle values, flexible hose as shown on drawing and as specified(American Standard) 7 No 0.00 0.00
3.2.4 Supply and installation of wall hang lavatory complete with mixing value, spout, pop-up waste,P-trap, angle valves, flexible hose,as shown on drawing and as specified (American Standard) 1 No 0.00 0.00
3.2.5 Supply and installation of shower tray complete with waste - trap, and showe head as shown on drawing and as specified (American Standard) 1 No 0.00 0.00
3.2.6 Supply and installation of Bath tub complete withdrain, drain trap, showes head, mixing value, spout, etc. as shown on drawing and as specified (American Standard) 3 No 0.00 0.00
3.2.7 Supply and installation of kitchen Sink stainless steelwith double bowl and drain board and trims(in counter type) 2 No 0.00 0.00
3.2.8 Supply and installation of cpvc Class-5 pipe forcold and for hot water pipe complete with all fittings,values, as shown on drawing and as specified. 1 L.S. 0.00 0.00
3.2.9 Supply and installation of elastomeric- rubberinsulation 6mm. thick for hot water supply pipe. 1 L.S. 0.00 0.00
3.2.10 Connect to the external system 1 L.S. 0.00 0.00
3.2.11 Supply, installation, connection and testing of water heater shown in drawing and directed by Engineer in charge. The price include isolation valve, pressure/tempara-ture valve, connection through pipe to drain and all nece-ssary accessories for complete installation(ERISTON) 10 No 0.00 0.00
3.2.12 Supply and installation of isolating valve as specified and shown in drawing.
63mm Dia50mm Dia40mm Dia 1 L.S 0.00 0.0032mm Dia25mm Dia19mm Dia
TOTAL0.00
CARRIED OVER
MECH-VILLA-J-
Page 35
BUILDING TYPE :VILLA "J"ITEM No DESCRIPTION QTY UNIT RATE TOTAL
3.1.13 Supply and installation of UPVC class-4 darinage pipeas specified and shown in Drawing.
160mm Dia110mm Dia75mm Dia65mm Dia 1 L.S 0.00 0.0050mm Dia40mm Dia
3.2.14 Supply and installation of Cast iron roof pipe drain as specified and shown in drawing
100mm Dia 1 L.S 0.00 0.00
3.2.15 Supply and installation of cast iron roof drain as specified and shown in drawing 6 No 0.00 0.00
3.2.16 Supply and installation of floor cleanout drain as 10 No 0.00 0.00 specified and shown in drawing
3.2.17 Supply and installation of floor drain as specified and shown in drawing 10 No 0.00 0.00
3.2.18 1 Set 0.00 0.00
TOTAL0.00
CARRIED OVER
Supply an installation of water pump set ( 1-running and 1-stand by) 40GPM 20M Head as shown in and as specified complete with all fitting and meter gauge for complete installation (GRUNDFUS)
MECH-VILLA-J-
Page 36
BUILDING TYPE :VILLA "J"ITEM No DESCRIPTION QTY UNIT RATE TOTAL
Page 1 0.00
Page 2 0.00
Page 3 0.00
Page 4 0.00
TOTAL0.00
CARRIED OVER
MECH-DUBAI-DRIVER
Page 37
BUILDING TYPE : DRIVERS' ANNEX
ITEM No DESCRIPTION QTY UNIT RATE TOTAL
3.0.0 MECHANICAL
3.1.0 HEATING, VENTILATION AND AIRCONDITION SYSTEM
3.1.1 Supply and installation of roof mounted Condensing Unitas specified, shown in drawing and directed by Engineerin charge. The price include with Evaporator, Compressorexpansion valve, factory pipe and supply with all control,Heater enclosed in steel enclosure and all other necessary.accessories for complete inatallation.
a) Split A/C Unit 18000 BTU3.1.3 Supply, nstallation , connection and testing Centrifugal
roof mounted exhaust fan as specified, shown in drawingand directed by Engineer. The price included all necessary
accessories for complete installation. 4 No 0.00 0.00
a) 250 CFM for Kitchen 2 No 0.00 0.00
b) 300 CFM for Toilet 2 No 0.00 0.00
3.1.4 Testing and commissioning of the HVAC system. 1 L.S 0.00 0.00
3.2.0 PLUMPING SYSTEM
3.2.1 Supply and installation of water closet westerntype complete with all trims, Cistern, angle value,Flexible steinless steel Hose, perivleal hose and
value as shown on drawing and as specified. 4 No 0.00 0.00
3.2.2 Supply and installation of counter top lavatory complete with mixing valve, spout, pop-up waste,P-trap, angle values, flexible hose as shown on
drawing and as specified. 4 No 0.00 0.003.2.3 Supply and installation of shower tray complete
drawing and as specified. 4 No 0.00 0.00
3.2.4 Supply and installation of kitchen Sink stainless steel
with double bowl and drain board and trims. 2 No 0.00 0.00
3.2.5 Supply and installation of Upvc Class-5 pipe forcold and cpvc for hot water pipe complete with all fittings,
values, as shown on drawing and as specified. 1 L.S. 0.00 0.00
3.2.6 Supply and installation of elastomeric- rubber
insulation 6mm. thick for hot water supply pipe. 1 L.S. 0.00 0.00
with waste - trap, and showe head mixing valve as shown on
MECH-DUBAI-DRIVER
Page 38
3.2.7 Connect to the external system 1 L.S. 0.00 0.00
TOTAL0
CARRIED OVER
MECH-DUBAI-DRIVER
Page 39
BUILDING TYPE : DRIVER'S ANNEXITEM No DESCRIPTION QTY UNIT RATE TOTAL
3.2.8 Supply, installation, connection and testing of water heater shown in drawing and directed by Engineer in charge. The price include isolation valve, pressure/tempara-ture valve, connection through pipe to drain and all nece-
ssary accessories for complete installation. 4 No 0.00 0.00
3.2.9 Supply and installation of isolating valve as specified and shown in drawing.
63mm Dia50mm Dia
40mm Dia 1 L.S 0.00 0.0032mm Dia25mm Dia19mm Dia
3.2.10 Supply and installation of UPVC class-4 darinage pipeas specified and shown in Drawing.
160mm Dia110mm Dia75mm Dia
65mm Dia 1 L.S 0.00 0.0050mm Dia40mm Dia
3.2.11 Supply and installation of Cast iron roof pipe drain as specified and shown in drawing
100mm Dia 1 L.S 0.00 0.00
3.2.12 Supply and installation of cast iron roof drain as
specified and shown in drawing 6 No 0.00 0.00
3.2.13 Supply and installation of floor cleanout drain as 6 No 0.00 0.00 specified and shown in drawing
3.2.14 Supply and installation of floor drain as
specified and shown in drawing 6 No 0.00 0.00
3.2.15 2 Set 0.00 0.00
TOTAL0.00
CARRIED OVER
Supply an installation of water pump set ( 1-running and 1-stand by) 25GPM 10M Head as shown in and as specified complete with all fitting and meter gauge for complete installation.
MECH-DUBAI-DRIVER
Page 40
BUILDING TYPE : DRIVER'S ANNEXITEM No DESCRIPTION QTY UNIT RATE TOTAL
Page 1 0
Page 2 0.00
TOTAL0.00
CARRIED OVER