F External Design Considerations - Smart Permanent Formwork

20
F External Design Considerations 2019 EDITION

Transcript of F External Design Considerations - Smart Permanent Formwork

Page 1: F External Design Considerations - Smart Permanent Formwork

F External Design Considerations

2019 EDITION

Page 2: F External Design Considerations - Smart Permanent Formwork

F1 Introduction

F2 Movement Joints

F3 Waterproofing

F4 Flashings

F5 Windows

F6 Finishing

F7 Finishing Systems Overview

F8 Cladding Systems

F9 Durability

F External Design Considerations

F

Ext

erna

l Des

ign

Con

side

ratio

ns

a f s l o g i c w a l l ® d e s i g n e r 2 0 1 9 122

Page 3: F External Design Considerations - Smart Permanent Formwork

F External Design Considerations

105WALLING SOLUTIONS DESIGNER 2012

F

E

xter

nal D

esig

n C

onsi

der

atio

ns

F1 Introduction

F2 Movement Joints

Draft v3 20/9/11

Panel A Panel B

LOGICWALLLOGICWALLPrefabricated LOGICWALL endcap stud site installed

NOTE: Can be dowel jointed if requiredstructurally. Must be clearly specified and negotiated with installers at time of tender

Backing strip and fire rated sealant by others

Detail #16

Structural Movement Joint

(Installed where nominated by projectengineer - must be clearly documentedon drawings. Typically not required inwalls less than 16m in length.)

AFS LOGICWALL AFS LOGICWALL® Prefabricated AFS endcap stud site installed by AFS LOGICWALL® installation contractor.

AFS LOGICWALL® panels are faced with 6mm fibre cement sheets which, at the completion of the construction process, provide the wall face and substrate for applied finishes and decorating.

The fibre cement sheets incorporate a special water block technology which reduces water penetrating into the sheet (refer to F3 – Waterproofing for more details). This not only assists in reducing water penetration of AFS LOGICWALL® throughout the construction phase of the project, before the final finishing system is applied, but also contributes to the overall durability of the product.

The final finish of AFS LOGICWALL® is influenced by factors such as movement and sheet surface joints, correct alignment of panels at installation stage, joint setting methods and applied finishing system.

The structural concrete wall effectively has control joints at each stud so no additional crack control joints are necessary. Full depth "movement joints" may be required depending on the geometry of the structure and other considerations such as thermal loads, exposure or building joints. In general "movement joints" would not be required for walls less than

There are a number of methods for ensuring that the finished AFS LOGICWALL® meets the user expectations. For best results these should be considered in the planning stages of the project and be clearly set out in specifications.

It is essential for the designers and builders to determine the level of finish required before construction begins otherwise it may not be possible to attain the desired finish level without extensive corrective measures.

For external wall application AFS LOGICWALL® can accommodate a range of external finishing solutions as set out in sections F5 - Finishing and F7 – Cladding Systems.

16m long. Structural "movement joints" will be placed in locations nominated by structural engineer and must be documented on structural drawings. These will be installed at construction stage by the AFS LOGICWALL® installation contractor. The following method is recommended.

Backing strip and fire rated sealant.

Fig. F2.1 Movement Joint Detail

F External Design Considerations

Note: Can be dowel jointed if required structurally. Must be clearly specified and negotiatied with installers at time of tender. Installed where nominated by project engineer. Must be clearly documented on drawings. Typically not required for walls less than 16mm in length.

Disclaimer: This section of the AFS Designer is intended only by AFS to represent good building practice in achieving suitable external design of AFS LOGICWALL®. This section is not intended in any way by AFS to represent all relevant information required on a project. It is the responsibility of those using AFS LOGICWALL®, including but not limited to builders, designers, consultants and engineers, to ensure that AFS LOGICWALL® is suitable for use on a project in relation to external design. All diagram, plans and illustrations used in this section including any reinforcement shown are included for indicative and diagrammatic purposes only. It remains the responsibility of those using AFS LOGICWALL® to ensure that reference is made to the structural engineer’s details for all diagrammatic and reinforcement requirements.

F

Ext

erna

l Des

ign

Con

side

ratio

ns

F

Ext

erna

l Des

ign

Con

side

ratio

ns

a f s l o g i c w a l l ® d e s i g n e r 2 0 1 9 123

Page 4: F External Design Considerations - Smart Permanent Formwork

106DESIGNER 2012 WALLING SOLUTIONS

F

E

xter

nal D

esig

n C

onsi

der

atio

ns

F3 Waterproofing

For any external façade design applicable to a building, it is essential that the system adopted is capable of withstanding the various environmental conditions which the façade is subject to during its life. In particular the prevention of water ingress into the building is critical.

AFS LOGICWALL® as an external façade, with an applied waterproofing coating performs as a successful barrier to water ingress and has been tried and proven on numerous buildings, many of which are in coastal locations. The system chiefly relies upon the following for waterproofing:

1. Adoption of horizontal slab junction details as recommended by AFS.

2. Appropriate location of flashings, especially to cap exposed parapet walls typically located on the top level of buildings.

3. Correct application of a quality external waterproofing coating system to supplier's specifications.

4. The water resistance of AFS LOGICWALL® itself, incorporating fibre cement facing sheets with water block technology properties.

Draft v3 20/9/11

Flashing

Continuous bead of LOGICWALL structural adhesive by AFS LOGICWALL® installation contractor.

Concrete wall to slab cold joint

Concrete floor slab to engineers details

Steel clinching angle and AFS LOGICWALL® frame within slab zone (can be removed onsite where required)

Detail #33

AFS Unfinished Boundary Wall Flashing Detail

Vertical and horizontal reinforcement to engineers details, by others

AFS LOGICWALL®

Two continuous beads of sealant under floor track on all external walls and internal separation walls by AFS LOGICWALL installation contractor.

HORIZONTAL SLAB JUNCTION DETAILS

Fig. F3.1 Unfinished Boundary Wall (adjacent to neighbouring building)

F

Ext

erna

l Des

ign

Con

side

ratio

ns

a f s l o g i c w a l l ® d e s i g n e r 2 0 1 9 124

Page 5: F External Design Considerations - Smart Permanent Formwork

107WALLING SOLUTIONS DESIGNER 2012

F

Ext

erna

l Des

ign

Con

sider

atio

ns

F3 Waterproofing continued

Fig. F3.2 Cover Strip Detail

Fig. F3.3.1 Flexible Extrusion Details - Horizontal Express Joint with Rebate in Slab Edge

9mm CFC cover

Flashing

strip or equivalent

Concete wall to slab cold joint

Sealant by others

Concrete floor slab to engineers details

Internal applied finishes by others

AFS LOGICWALL®

Starter bars

Two continuous beads of sealant under floor track on all external walls and internal separation wallsby AFS LOGICWALL installation contractor

Vertical and horizontalreinforcement to engineersdetails

Steel clinching angle and AFS LOGICWALL® frame within slab zone (can be removed onsite where required)

Detail #3

Horizontal Joint with cover plate on slab edge

Draft v3 20/9/11

Wall to slab cold joint

The horizontal joint is recessed on site by others

Joint is taped and set with external coating system by external coating applicator

The 20mm PVCrender mould section is applied to the joint (by external coating applicator)

Paintable waterproofing membrane

Set down in slab recommended

20mm

Steel clinching angle and AFS LOGICWALL® frame within slab zone (can be removed onsite where required)

Concrete floor slab to engineers details

Two continuous beads of sealant under floor track on all external walls and internal separation walls by AFS LOGICWALL®

Vertical and horizontal reinforcement to engineers details, by others

LOGICWALL

Detail #1

Horizontal Express Joint with Rebate in Slab Edge

installation contractor

200mm PVC Mould

F

Ext

erna

l Des

ign

Con

side

ratio

ns

F

Ext

erna

l Des

ign

Con

side

ratio

ns

a f s l o g i c w a l l ® d e s i g n e r 2 0 1 9 125

Page 6: F External Design Considerations - Smart Permanent Formwork

108DESIGNER 2012 WALLING SOLUTIONS

F

E

xter

nal D

esig

n C

onsi

der

atio

ns

F3 Waterproofing continued

Draft v3 20/9/11

9mm CFC cover strip or equivalent

Flashing

Concrete wall to slab cold joint

Sealant

Concrete floor slabto engineers details

Plasterboard sheeting

Preformed hob system

40mm membraned cavity

Steel clinching angle on LOGICWALL® frame within slab zone (can be removed onsite where required)

Two continuous beads of sealant under floor track on all external walls and internal separation walls

AFS LOGICWALL®

Vertical and horizontal reinforcement to engineers details

Detail #43

Cavity Wall Detail Flat Slab

by AFS LOGICWALL® installation contractor

Fig. F3.3.2 Flexible Extrusion Details- Horizontal Express Joint with Waterproofing on Flat Plate Slab Edge

Fig. F3.4 Cavity Wall with Hob Detail - Flat SlabDraft v3 20/9/11

Wall to slab cold joint

1. The horizontal joint is recessed on site

2. Joint is taped and set with external water proofing membrane by external coating applicator

3. The 20mm PVC render mould section is applied to the joint (by external coating applicator)

4. External Finishes to project specifications (Refer recommended finishes schedule)

Vertical and horizontal reinforcement to engineers

Steel clinching angle and AFS LOGICWALL® frame within slab zone (can be removed on site where required)

Concrete floor slab to engineers details

Detail #2

Horizontal Express Joint withFlat Plate Slab Edge

details

AFS LOGICWALL®

Two continuous beads of sealant under floor track on all external walls and internal separation walls by AFS LOGICWALL® installation contractor

Paintable waterproofing membrane

F

Ext

erna

l Des

ign

Con

side

ratio

ns

a f s l o g i c w a l l ® d e s i g n e r 2 0 1 9 126

Page 7: F External Design Considerations - Smart Permanent Formwork

109WALLING SOLUTIONS DESIGNER 2012

F

E

xter

nal D

esig

n C

onsi

der

atio

ns

2. For Boundary Walls not able to be sealedor coated due to proximity of the neighbouringbuilding – an Alcor flexible flashing (or similar) is required toprevent water ingress through the horizontal joint.

1. Boundary Walls – the cavity between the externalAFS LOGICWALL® and the neighbouring building must be fully flashed to prevent water ingress onto the often uncoated AFS LOGICWALL®.

The use of flashings applies to the following areas of AFS LOGICWALL® construction:

Draft v3 20/9/11

AFS LOGICWALL®

External finishing system

Cut thought fibre cement sheeting and treat cut area with suitable waterproofing system

Waterproofing sealant

Flashing angle

Detail #32

AFS Unfinished Boundary Wall Flashing Detail

Colourbond / Zincalume capping

AFS LOGICWALL®

Continuous bead of AFS structural adhesive by AFS LOGICWALL® installation contractor

F4 Flashings

Fig. F4.1

Fig. F4.3

Fig. F4.2

3. Top of Walls – The exposed top of AFS LOGICWALL® is vulnerable to water ingress. It is mandatory that a flashing, Colourbond or Zincalume, is installed to cap the top of exposed AFS LOGICWALL® panels to prevent water ingress.

Steel clinching angle on LOGICWALL® frame within slab zone (can be removed onsite where required)

F

Ext

erna

l Des

ign

Con

side

ratio

ns

F

Ext

erna

l Des

ign

Con

side

ratio

ns

a f s l o g i c w a l l ® d e s i g n e r 2 0 1 9 127

Page 8: F External Design Considerations - Smart Permanent Formwork

110DESIGNER 2012 WALLING SOLUTIONS

F

E

xter

nal D

esig

n C

onsi

der

atio

ns

F5 Windows

F6 Finishing

AFS recommends the following two details for successful window installation in AFS LOGICWALL®, which both adopt a commercial or semi-commercial window section incorporating a sub-head and sub-sill.

Fig. F5.1

Commercial window Section Detail – Flat Reveal

AFS LOGICWALL® external walls require the application of high build, trowel applied, flexible Acrylic Texture System to achieve:

a) A water resistant building envelope, and

b) An aesthetically pleasing building appearance.

AFS’s preferred manufacturer for external coating systems is Dulux AcraTex who supply a range of finishing system options relative to the degree of surface leveling required and preferred aesthetic style.

Fig. F5.2

Commercial Window Section Detail – Rebated Head Reveal

Note: AFS do not recommend the application of cementitious render levelling or finishing systems as these are rigid and do not allow for normal expansion and contraction movement.

The application of conventional paint or roll on texture coatings directly onto the AFS LOGICWALL® fibre cement sheeting will result in visible panel joints and imperfections in the substrate.

Draft v3 20/9/11

Fibre cement sheet

Drainage slots

Fibre cement sheet

Subhead

Subsill

Glazing

Extra reinforcing bars above and below opening - As per project engineer’s details

Custom formed blank closing stud to suit head + stile sections

AFS LOGICWALL®

Seal the vertical and horizontal fibre cement/concrete window surrounds with paintable water proof membrane prior to fitting of subframe or application of any finishes, by others. Ensure product used is compatible with specified finishes

Detail #27

Commercial Window Section

Extra reinfoceing bars above and below opening - As per project engineer’s details

110DESIGNER 2012 WALLING SOLUTIONS

F

E

xter

nal D

esig

n C

onsi

der

atio

ns

F5 Windows

F6 Finishing

AFS recommends the following two details for successful window installation in AFS LOGICWALL®, which both adopt a commercial or semi-commercial window section incorporating a sub-head and sub-sill.

Fig. F5.1

Commercial window Section Detail – Flat Reveal

AFS LOGICWALL® external walls require the application of high build, trowel applied, flexible Acrylic Texture System to achieve:

a) A water resistant building envelope, and

b) An aesthetically pleasing building appearance.

AFS’s preferred manufacturer for external coating systems is Dulux AcraTex who supply a range of finishing system options relative to the degree of surface leveling required and preferred aesthetic style.

Fig. F5.2

Commercial Window Section Detail – Rebated Head Reveal

Note: AFS do not recommend the application of cementitious render levelling or finishing systems as these are rigid and do not allow for normal expansion and contraction movement.

The application of conventional paint or roll on texture coatings directly onto the AFS LOGICWALL® fibre cement sheeting will result in visible panel joints and imperfections in the substrate.

Draft v3 20/9/11

Fibre cement sheet

Drainage slots

Fibre cement sheet

Subhead

Subsill

Glazing

Extra reinforcing bars above and below opening - As per project engineer’s details

Custom formed blank closing stud to suit head + stile sections

AFS LOGICWALL®

Seal the vertical and horizontal fibre cement/concrete window surrounds with paintable water proof membrane prior to fitting of subframe or application of any finishes, by others. Ensure product used is compatible with specified finishes

Detail #27

Commercial Window Section

Extra reinfoceing bars above and below opening - As per project engineer’s details

F

Ext

erna

l Des

ign

Con

side

ratio

ns

a f s l o g i c w a l l ® d e s i g n e r 2 0 1 9 128

Page 9: F External Design Considerations - Smart Permanent Formwork

111WALLING SOLUTIONS DESIGNER 2012

F

E

xter

nal D

esig

n C

onsi

der

atio

ns

F7 Finishing Systems Overview

AFS has worked with Dulux AcraTex to design systems that accommodate the specific requirements of the AFS Building Systems and deliver warranted systems for long term performance.

AFS strongly recommend the application of full acrylic, trowel applied texture coat systems, rather than conventional paints, in order to help conceal panel joints and imperfections which would be visible in critical and glancing light conditions. Texture roller applied stipple finishes are suitable where specific attention is given to ensuring a suitable high standard of finishing of base skimcoat is achieved.

AFS do not recommend high cement under render applications.

Responsibilities of Dulux AcraTex

To supply quality facade coating systems and specifications together with technical advice and representation to AFS projects through its Dulux AcraTex support network. Dulux shall also supply all technical back up applicator training and material warranties to ensure optimal performance of the specified coating system.

Materials & Application Warranty

Dulux AcraTex shall provide AFS Systems Pty Ltd and its clients with a material performance warranty for a period of no less than:Ten (10) years from the date of application where a fully recommended Dulux AcraTex coating system is installed as per the Approved Coating Systems Table (Fig 7.5).Fifteen (15) year Warranty may be issued where an additional weatherproofing finish coat of AcraShield or AcraSkin is applied to approved systems.

Ten (10) year Extended Warranty may be issued, where after the initial warranty period, re-application of the weatherproofing finishing coat(s) is undertaken with either A craShield of AcraSkin in accordance with appropriate specification relative to the conditions as set out in the Dulux AcraTex Materials and Dulux AcraTex Trained Applicator workmanship warranty.

AFS LOGICWALL® Wall Substrate Installation Standards & Alignments

AFS LOGICWALL panels shall be installed in strict accordance with the AFS Systems Pty Ltd recommendations. Foroptimum finishing system efficiencies, AFS LOGICWALL® panel section alignment shall be true and plumb with maximum alignment variation of +/-4mm. Where tolerances exceed optimum specification, alternate Remedial High Build Coatings System recommendations apply as detailed in (Fig 7.1) and shall be considered variations for contacting purposes. Additionally, it is important to ensure minimum variation of floor to floor alignment together with correct installation of control joints over large area and at floor to floor sections, window or other openings of the structure to allow adequate movement of the building envelope.

Responsibilities of Applicator(s)

The nominated Applicator(s) shall deliver all materials and labour to complete the works to the agreed colour, timeframe and standard in full accordance with the latest data provided by Dulux AcraTex on the AFS Facade coating system.

i.e approved systems incorporating 2 weatherproofingfinish coats or AcraShield or AcraSkin.

F

Ext

erna

l Des

ign

Con

side

ratio

ns

F

Ext

erna

l Des

ign

Con

side

ratio

ns

a f s l o g i c w a l l ® d e s i g n e r 2 0 1 9 129

Page 10: F External Design Considerations - Smart Permanent Formwork

112DESIGNER 2012 WALLING SOLUTIONS

F

E

xter

nal D

esig

n C

onsi

der

atio

ns

B. Texture Roller Applied, "Stipple Finish":AcraTex AcraSkin

AcraTex AcraSkin is an Elastomeric Membrane coating applied by medium cell Texture Roller delivering a weatherproofing, highly flexible light relieve texture stipple.

AcraSkin is also specified as the final weatherproofing topcoat, applied by a nap roller.

Where misalignment is >4mm refer to supplementary Dulux AcraTex Remedial Recommendation Specifications for additional substrate pre-filling and treatment.

Such remedial works is outside the scope of normal coatings installation and requires project agreement on scope of coatings, remedial specification and additional coating system cost.

AFS LOGICWALL™ Minimum Coating System Requirements Minimum System Performance

Jointing & Base leveling system

JOINT FLUSHING – Dulux AcraTex AcraPatch Coarse Flexible Acrylic Jointing Compound incorporating alkali resistant Reinforcement Mesh Reinforcement tape must be embedded in a “wet on wet sandwich” process to ensure maximum integrity of the joint.

High Build, Acrylic, Elastomeric system, independently tested to AS4548.5

CrackBridging Capability1mm minimum

(total system performance) when tested to AS4548.5 Appendix F

Water Transmission less than 10g/24h/m2/kPa

when tested to AS3448.5 Appendix B

Moisture Vapour Permeability> 50 g /m2 /24h

when tested to AS4548.5 Appendix C

Apply 2 coats with a 12-18mm nap roller ensuring a continuous wet edge is

maintained. Do not Dry cut in. 2 coats are recommended to ensure even coverage, best appearance and maximum durability.

BASE SKIMCOAT – AcraTex AcraPatch High BuildFlexible Acrylic, High Build (2-6mm), Floatable Levelling and Patching compond for masonry surfaces.Requires the addition of 5% cement. Applied by Hawk and Trowel as a skim coat or up to 6mm build coat for float finishing.

Texture & Weatherproofing Finish

Texture Finish System Option A

TROWEL FLOAT SAND FINISH

AcraTex Coventry Coarse Applied by Hawk & Trowel

Float Finish to a leveied sand finish style

Texture Finish System Option B Requires high standard of Base Skimcoat Finish

TExTURE STIPPLE FINISH

AcraTex AcraSkin Applied by Medium Texture Roller to provide a

light relieve texture stipple finish

WEATHERPROOFING TOPCOAT

AcraTex AcraShield Matt High Build Elastomeric Matt Finish

WEATHERPROOFING TOPCOAT

AcraTex AcraSkin High Build Elastomeric

Low Sheen FinishMax. crack bridging resistance

F7 Finishing Systems Overview continued

Fig 7.1The following minimum coating system specification is applicable where panel alignment is true and level (<4mm deviation)

Dulux AcraTex Coating Systems recommendation for AFS LOGICWALL® have been designed to provide 2 aesthetic options, over base jointing and levelling coats, relative to project requirements:

A. Trowel Applied "Float Sand Finish": AcraTex Coventry Coarse Trowel On

AcraTex Coventry Coarse is a flexible acrylic texture, applied at 1-2mm film build delivering a traditional float finish render style in a fine-medium grain texture.

AcraTex or AcraSkin is specified as the final weatherproofing topcoat.

Note: Texture Roller Stipple finish requires a higher standard of Base Skimcoat float finishing to achieve optimum aesthetics.

F

Ext

erna

l Des

ign

Con

side

ratio

ns

a f s l o g i c w a l l ® d e s i g n e r 2 0 1 9 130

Page 11: F External Design Considerations - Smart Permanent Formwork

113WALLING SOLUTIONS DESIGNER 2012

F

E

xter

nal D

esig

n C

onsi

der

atio

ns

F7 Finishing Systems Overview continued

Fig. F7.2 - Trowel Float Sand Finish - Exterior Finishing System - Option A

DuSpec Specification Sheet DULUX® AcraTex® Coating System for AFS LOGICWALL™ Building System. Coventry Coarse Trowel Applied Finish

Duspec DULUX AcraTex – AFS WALL AcraPatch High Build Finishing SystemCoventry Coarse Trowel Applied Finish Prepared By Shane Langkilde

Page 1 of 2Duspec No AC1201 Issue No 4 Date 01.04.2012 Approved By Ian Schultz

DISCLAIMER:Any advice, recommendation, information, assistance or service provided by any of the divisions of DuluxGroup Products in relation to goods manufactured by it or their use and application is given in good faith and is believed by DuluxGroup to be appropriate and reliable. However, any advice, recommendation, information, assistance or service provided by DuluxGroup is provided without liabilityor responsibility PROVIDED THAT the foregoing shall not exclude, limit, restrict or modify the right entitlements and remedies conferred upon any person or the liabilities imposed upon DuluxGroup byany condition or warranty implied by Commonwealth, State or Territory Act or ordinance void or prohibiting such exclusion limitation or modification. Coating systems can be expected to perform asindicated on the Duspec Spec Sheet so long as applications and application procedures of the individual products are followed as recommended on the appropriate Product data SheetThe data provided within the Duspec system is correct at the time of publication, however it is the responsibility of those using this information to check that it is current prior to specifying or using any ofthese coating systems.This specification should be read in conjunction with the Product Datasheets specified within this document.

"Dulux" "Berger" "Berger Gold Label" "Hadrian" "Walpamur" "Levene" "AcraTex" are registered trademarks of DuluxGroup Pty Ltd ABN . 67 000 049 427

Substrate: AFS LOGIC WALLTM is an innovative fast track permanent formwork system used as load bearing external and internal wall solutions for both residential & commercial construction. AFS Walling Panels incorporate CSR Cementel Fibre Cement Sheeting – CEMINSEAL WALLBOARD with WATERLOCK technology.

Substrate Preparation: Frame detail and panel fixing must comply with relevant building codes and be in strict accordance with substrate manufactures instructions & recommendations. Dulux AcraTex recommends suitable expansion/contraction relief joints be installed at natural building weak points eg in line with openings (window / doors), at all horizontal multilevels, and at all interfaces of different building construction materials and or as defined by Engineer. All fixings must be noncorrosive, suitable for the exposure condition and be in accordance with substrate supplier recommendations.

Panel Face & Joint Alignment Panel alignment is critical in all lost formwork systems and specific attention must be given to control of joint & sheeting alignment. Ensure that all joints between panelsaccurately align and floortofloor alignment ensures a true and flat plane across the elevation. It is the responsibility of the panel installer to ensure all joints or major imperfections, misalignments are filled and sanded true & flush before applying any coatings system. Remove all surface contaminants such as oil, grease or dirt, dust by hosing suitable detergent /pressure wash before coating.

NOTE :

THIS SYSTEM IS SUITABLE WHERE PANEL ALIGNMENT TOLLERANCES ≤4MM WHERE MAJOR MISALIGNMENT OCCURS, REFER TO ADDITIONAL REMEDIAL RECOMMENDATIONS FOR PRETREATMENT

Expansion Joints: CJ’s are best treated before the coating system is applied. The use of a PU Poly Urethane ‘paintable’ Sealant incorporating backing rod in strict accordance with the manufacturer recommendation for use on AFS WallTM should be used in all cases. Select a colour that is complimentary to the final Texture colour. Apply Sealant on completion of the panel installation prior to coatings system application.

AFS WALLTM COATING SYSTEM Data Sheet

Application Rate Recoat ** @250C & 50% RH

JOINT FLUSHING DULUX AcraPatch Course L/Shade 19420806

Mix AcraPatch Course with 10% Portland Cement and apply to joint recess and immediately install AcraTex Reinforcing Tape into the wet AcraPatch followed by further AcraPatch to fill the recess. Application of AcraPatch should be ‘wet on wet’ to insure maximum integrity of the joint.

AUSA 2925 12 m2 per Litre 8 hour

BASE COAT DULUX AcraTex – AcraPatch High Build L/Shade 19485841

Mix Ratio 15L AcraTex 500/11 AcraPatch HB; 300mls Portland Cement (5%) Use a power mixing device to mix thoroughly. Ensure that all imperfections are filled, work away from the sun (in shaded areas). Apply with Hawk & Trowel evenly over surface to the thickness 25mm in a single pass. DO NOT overspread the material. Follow up with a light ‘floating’ process to level out the product using a polystyrene or red plastic float.

AUDA0440

0.8L / m2 / mm

1x15L AcraPatch HB

will cover 6 m2 @ 2mm thick

16 Hours

Protect from rain in first 24 hours

OPTIONAL PRIMER COAT DULUX AcraTex – AcraPrime Water based Line/Shade 19420902

Used to improve application and workability of texture coat. Apply 1 coat with a 12mm nap roller over the surface ensuring a wet edge is maintained over the application area.

AUDA0441 10 m2 / Litre per Coat

4 Hours

Protect from rain in first 24 hours

TEXTURE COAT DULUX AcraTex – Coventry Coarse L/Shade 19485753

Apply with Hawk & Trowel evenly over surface to the thickness of the largest particles in a single pass. Follow up with a light ‘floating’ process to level out the product using a red plastic float trowel.

AUDA1065 1.1 m2 / Litre

16 Hours

Protect from rain in first 24 hours

TOP COAT DULUX AcraTex AcraShield Line/Shade 19451950

Apply 2 coats with a 12mm nap roller over the surface ensuring a wet edge is maintained over the application area – whilst one coat will provide adequate protection from the elements we recommend the application of 2 coats the first diluted with 10% water and the second with only 5% water to ensure an even finish is achieved.

Dulux recommends 2 coats application for even coverage to minimising “cutting in” and “lap marks” effects.

AUDA0432 5 m2 / Litre per Coat

4 Hours

Protect from rain in first 24 hours

DuSpec Specification SheetDULUX® AcraTex® Coating System for AFS LOGICWALL™ Building System.Coventry Coarse Trowel Applied Finish

Duspec DULUX AcraTex – AFS WALL AcraPatch High Build Finishing System Coventry Coarse Trowel Applied Finish Prepared By Shane Langkilde

Page 1 of 2 Duspec No AC1201 Issue No 4 Date 01.04.2012 Approved By Ian Schultz

DISCLAIMER: Any advice, recommendation, information, assistance or service provided by any of the divisions of DuluxGroup Products in relation to goods manufactured by it or their use and application is given in good faith and is believed by DuluxGroup to be appropriate and reliable. However, any advice, recommendation, information, assistance or service provided by DuluxGroup is provided without liability or responsibility PROVIDED THAT the foregoing shall not exclude, limit, restrict or modify the right entitlements and remedies conferred upon any person or the liabilities imposed upon DuluxGroup by any condition or warranty implied by Commonwealth, State or Territory Act or ordinance void or prohibiting such exclusion limitation or modification. Coating systems can be expected to perform as indicated on the Duspec Spec Sheet so long as applications and application procedures of the individual products are followed as recommended on the appropriate Product data Sheet The data provided within the Duspec system is correct at the time of publication, however it is the responsibility of those using this information to check that it is current prior to specifying or using any of these coating systems. This specification should be read in conjunction with the Product Datasheets specified within this document. "Dulux" "Berger" "Berger Gold Label" "Hadrian" "Walpamur" "Levene" "AcraTex" are registered trademarks of DuluxGroup Pty Ltd ABN . 67 000 049 427

Substrate:AFS LOGIC WALLTM is an innovative fast track permanent formwork system used as load bearing external and internal wall solutions for both residential & commercialconstruction. AFS Walling Panels incorporate CSR Cementel Fibre Cement Sheeting – CEMINSEAL WALLBOARD with WATERLOCK technology.

Substrate Preparation:Frame detail and panel fixing must comply with relevant building codes and be in strict accordance with substrate manufactures instructions & recommendations.Dulux AcraTex recommends suitable expansion/contraction relief joints be installed at natural building weak points eg in line with openings (window / doors), at all horizontalmultilevels, and at all interfaces of different building construction materials and or as defined by Engineer.All fixings must be noncorrosive, suitable for the exposure condition and be in accordance with substrate supplier recommendations.

Panel Face & Joint AlignmentPanel alignment is critical in all lost formwork systems and specific attention must be given to control of joint & sheeting alignment. Ensure that all joints between panelsaccurately align and floortofloor alignment ensures a true and flat plane across the elevation.It is the responsibility of the panel installer to ensure all joints or major imperfections, misalignments are filled and sanded true & flush before applying any coatings system.Remove all surface contaminants such as oil, grease or dirt, dust by hosing suitable detergent /pressure wash before coating.

NOTE :THIS SYSTEM IS SUITABLE WHERE PANEL ALIGNMENT TOLLERANCES ≤4MM

WHERE MAJOR MISALIGNMENT OCCURS, REFER TO ADDITIONAL REMEDIAL RECOMMENDATIONS FOR PRETREATMENT

Expansion Joints:CJ’s are best treated before the coating system is applied. The use of a PU Poly Urethane ‘paintable’ Sealant incorporating backing rod in strict accordance with the manufacturer recommendation for use on AFS WallTM should be used in all cases. Select a colour that is complimentary to the final Texture colour. Apply Sealant on completion of the panel installation prior to coatings system application.

AFS WALLTM COATING SYSTEM DataSheet

Application Rate Recoat **@250C & 50% RH

JOINT FLUSHINGDULUX AcraPatch Course L/Shade 19420806

Mix AcraPatch Course with 10% Portland Cement and apply to joint recess and immediately installAcraTex Reinforcing Tape into the wet AcraPatch followed by further AcraPatch to fill the recess. Application of AcraPatch should be ‘wet on wet’ to insure maximum integrity of the joint.

AUSA 2925 12 m2 per Litre 8 hour

BASE COATDULUX AcraTex – AcraPatch High Build L/Shade 19485841

Mix Ratio15L AcraTex 500/11 AcraPatch HB; 300mls Portland Cement (5%)Use a power mixing device to mix thoroughly.Ensure that all imperfections are filled, work away from the sun (in shaded areas).Apply with Hawk & Trowel evenly over surface to the thickness 25mm in a single pass.DO NOT overspread the material.Follow up with a light ‘floating’ process to level out the product using a polystyrene or red plastic float.

AUDA0440

0.8L / m2 / mm

1x15L AcraPatch HB

will cover6 m2 @ 2mm thick

16 Hours

Protect from rain in first 24 hours

OPTIONAL PRIMER COATDULUX AcraTex – AcraPrime Water based Line/Shade 19420902

Used to improve application and workability of texture coat.Apply 1 coat with a 12mm nap roller over the surface ensuring a wet edge is maintained over the application area.

AUDA0441 10 m2 / Litreper Coat

4 Hours

Protect from rain in first 24 hours

TEXTURE COATDULUX AcraTex – Coventry Coarse L/Shade 19485753

Apply with Hawk & Trowel evenly over surface to the thickness of the largest particles in a single pass.Follow up with a light ‘floating’ process to level out the product using a red plastic float trowel.

AUDA1065 1.1 m2 / Litre

16 Hours

Protect from rain in first 24 hours

TOP COATDULUX AcraTex AcraShield Line/Shade 19451950

Apply 2 coats with a 12mm nap roller over the surface ensuring a wet edge is maintained over theapplication area – whilst one coat will provide adequate protection from the elements we recommend the application of 2 coats the first diluted with 10% water and the second with only 5% water to ensure an even finish is achieved.

Dulux recommends 2 coats application for even coverage to minimising “cutting in” and “lap marks”effects.

AUDA0432 5 m2 / Litreper Coat

4 Hours

Protect from rain in first 24 hours

It is the responsibility of the panel installer or coatings applicator, to ensure all joints or major imperfections, misalignments are filled and sanded true & flush before applying any coatings system.

DULUX AcraTex - AFS LOGICWALL AcraPatch High Build Finishing SystemCoventry Coarse Trowel Applied Finish

AFS LOGICWALL COATING SYSTEM

F

Ext

erna

l Des

ign

Con

side

ratio

ns

F

Ext

erna

l Des

ign

Con

side

ratio

ns

a f s l o g i c w a l l ® d e s i g n e r 2 0 1 9 131

Page 12: F External Design Considerations - Smart Permanent Formwork

114DESIGNER 2012 WALLING SOLUTIONS

F

E

xter

nal D

esig

n C

onsi

der

atio

ns

DuSpec Specification SheetDULUX® AcraTex® Coating System for AFS LOGICWALL™ Building System.Coventry Coarse Trowel Applied Finish

Duspec DULUX AcraTex – AFS WALL AcraPatch High Build Finishing System Coventry Coarse Trowel Applied Finish Prepared By Shane Langkilde

Page 2 of 2 Duspec No AC1201 Issue No 4 Date 01.04.2012 Approved By Ian Schultz

DISCLAIMER: Any advice, recommendation, information, assistance or service provided by any of the divisions of DuluxGroup Products in relation to goods manufactured by it or their use and application is given in good faith and is believed by DuluxGroup to be appropriate and reliable. However, any advice, recommendation, information, assistance or service provided by DuluxGroup is provided without liability or responsibility PROVIDED THAT the foregoing shall not exclude, limit, restrict or modify the right entitlements and remedies conferred upon any person or the liabilities imposed upon DuluxGroup by any condition or warranty implied by Commonwealth, State or Territory Act or ordinance void or prohibiting such exclusion limitation or modification. Coating systems can be expected to perform as indicated on the Duspec Spec Sheet so long as applications and application procedures of the individual products are followed as recommended on the appropriate Product data Sheet The data provided within the Duspec system is correct at the time of publication, however it is the responsibility of those using this information to check that it is current prior to specifying or using any of these coating systems. This specification should be read in conjunction with the Product Datasheets specified within this document. "Dulux" "Berger" "Berger Gold Label" "Hadrian" "Walpamur" "Levene" "AcraTex" are registered trademarks of DuluxGroup Pty Ltd ABN . 67 000 049 427

Important Notes:

Coatings should be applied in full accordance with relative product Technical and Applicational data sheets.This system is recommended where panel misalignment is NOT greater than 4mm. Refer to Remedial Specification recommendations where panel misalignment is greater than 4mm.

Practical spreading rates will vary from quoted theoretical figures depending on substrate porosity, surface roughness, misalignment, overspray losses, application methods and environmental conditions (eg wind).

Protect from rain and frost for 24 hours when apply at the recommended spread rate.Dry times apply to a single coat at recommended spread rate and at 25oC and 50% Relative HumidityAllow longer times under cool, moist, or still conditions and or when applied at high film builds.

Do not apply paint if Relative Humidity is above 85% or temperature is within 3°C of Dew Point.Do not apply if the surface temperature is greater than 40°C or below 10°C, or likely to fall below 10°C during the application or drying period.

When using Bright Reds, Oranges, Blues and Yellows or where very light colours are applied over highly contrasting colours an extra coat maybe required.

At Commencement of coating system application to the substrate it shall be deemed that the Applicator has certified that the surface which it is to be applied to is fit receive the specified coating(s) system.When the Applicator is preparing the site sample for approval he should advise the Project Superintendent if the substrate condition is not of sufficient standard to produce the specified finish.

Where possible avoid dark colours these will give raise to much higher surface temperature that may cause addition thermal stress and cooling demand to the building envelope and/ or require extra engineering considerations(Greater building costs).Consult Dulux on the potential to use InfraCOOL Heat Reflective Coatings that will keep the surface cooler.

The coastal area is considered a marine environment and as such salt potentially can shorten the life of the coating systems. Care needs to be taken to wash down allareas twice. Once to remove surface contaminants, and raise salts to the surface and then secondly to remove these salts. Due to the locality, Weather conditions and lag time between applications of the coating system it may require the need to wash again, between coats.

A DULUX warranty can be provided on request when the full AcraTex system is applied by a DULUX AcraTex trained applicator, according to specification, & at the specified spreading rates, & to the surface preparation details described in the DULUX AcraTex Specification Manual.

The dynamics of the substrate are outside the control of Dulux Australia and as such joint deformation or cracking is excluded from warranty terms. Refer warrantydocument for full terms.

Glancing lightJoints and panel deformation may be clearly evident under glancing light, casting visible shadows of the minute and uneven projections of the joints. Glancing light islight that is nearly parallel to the surface of the wall and casts visible shadows and uneven projections of the joints. Just like rendered masonry/ Jointed system anyuneven projections will be highlighted and as such are outside the control / scope of this specification.

When using this specification, the Applicator shall maintain records in accordance with AS3894 Parts 10, 11 and 12 and others as required by the Project Manager.These records shall be made available for inspection at any time by the Project Manager or authorised representative and submitted to the Principal Contractor upon completion of work.

Fig. F7.2 - Trowel Float Sand Finish - Exterior Finishing System - Option A continued

DuSpec Specification Sheet DULUX® AcraTex® Coating System for AFS LOGICWALL™ Building System. Coventry Coarse Trowel Applied Finish

Duspec DULUX AcraTex – AFS WALL AcraPatch High Build Finishing SystemCoventry Coarse Trowel Applied Finish Prepared By Shane Langkilde

Page 2 of 2Duspec No AC1201 Issue No 4 Date 01.04.2012 Approved By Ian Schultz

DISCLAIMER:Any advice, recommendation, information, assistance or service provided by any of the divisions of DuluxGroup Products in relation to goods manufactured by it or their use and application is given in good faith and is believed by DuluxGroup to be appropriate and reliable. However, any advice, recommendation, information, assistance or service provided by DuluxGroup is provided without liabilityor responsibility PROVIDED THAT the foregoing shall not exclude, limit, restrict or modify the right entitlements and remedies conferred upon any person or the liabilities imposed upon DuluxGroup byany condition or warranty implied by Commonwealth, State or Territory Act or ordinance void or prohibiting such exclusion limitation or modification. Coating systems can be expected to perform asindicated on the Duspec Spec Sheet so long as applications and application procedures of the individual products are followed as recommended on the appropriate Product data SheetThe data provided within the Duspec system is correct at the time of publication, however it is the responsibility of those using this information to check that it is current prior to specifying or using any ofthese coating systems.This specification should be read in conjunction with the Product Datasheets specified within this document.

"Dulux" "Berger" "Berger Gold Label" "Hadrian" "Walpamur" "Levene" "AcraTex" are registered trademarks of DuluxGroup Pty Ltd ABN . 67 000 049 427

Important Notes:

Coatings should be applied in full accordance with relative product Technical and Applicational data sheets. This system is recommended where panel misalignment is NOT greater than 4mm. Refer to Remedial Specification recommendations where panel misalignment is greater than 4mm.

Practical spreading rates will vary from quoted theoretical figures depending on substrate porosity, surface roughness, misalignment, overspray losses, application methods and environmental conditions (eg wind).

Protect from rain and frost for 24 hours when apply at the recommended spread rate. Dry times apply to a single coat at recommended spread rate and at 25oC and 50% Relative Humidity Allow longer times under cool, moist, or still conditions and or when applied at high film builds.

Do not apply paint if Relative Humidity is above 85% or temperature is within 3°C of Dew Point.Do not apply if the surface temperature is greater than 40°C or below 10°C, or likely to fall below 10°C during the application or drying period.

When using Bright Reds, Oranges, Blues and Yellows or where very light colours are applied over highly contrasting colours an extra coat maybe required.

At Commencement of coating system application to the substrate it shall be deemed that the Applicator has certified that the surface which it is to be applied to is fit receive the specified coating(s) system. When the Applicator is preparing the site sample for approval he should advise the Project Superintendent if the substrate condition is not of sufficient standard to produce the specified finish.

Where possible avoid dark colours these will give raise to much higher surface temperature that may cause addition thermal stress and cooling demand to the building envelope and/ or require extra engineering considerations (Greater building costs). Consult Dulux on the potential to use InfraCOOL Heat Reflective Coatings that will keep the surface cooler.

The coastal area is considered a marine environment and as such salt potentially can shorten the life of the coating systems. Care needs to be taken to wash down all areas twice. Once to remove surface contaminants, and raise salts to the surface and then secondly to remove these salts. Due to the locality, Weather conditions and lag time between applications of the coating system it may require the need to wash again, between coats.

A DULUX warranty can be provided on request when the full AcraTex system is applied by a DULUX AcraTex trained applicator, according to specification, & at the specified spreading rates, & to the surface preparation details described in the DULUX AcraTex Specification Manual.

The dynamics of the substrate are outside the control of Dulux Australia and as such joint deformation or cracking is excluded from warranty terms. Refer warranty document for full terms.

Glancing light Joints and panel deformation may be clearly evident under glancing light, casting visible shadows of the minute and uneven projections of the joints. Glancing light is light that is nearly parallel to the surface of the wall and casts visible shadows and uneven projections of the joints. Just like rendered masonry/ Jointed system any uneven projections will be highlighted and as such are outside the control / scope of this specification.

When using this specification, the Applicator shall maintain records in accordance with AS3894 Parts 10, 11 and 12 and others as required by the Project Manager. These records shall be made available for inspection at any time by the Project Manager or authorised representative and submitted to the Principal Contractor upon completion of work.

F7 Finishing Systems Overview continued

F

Ext

erna

l Des

ign

Con

side

ratio

ns

a f s l o g i c w a l l ® d e s i g n e r 2 0 1 9 132

Page 13: F External Design Considerations - Smart Permanent Formwork

115WALLING SOLUTIONS DESIGNER 2012

F

E

xter

nal D

esig

n C

onsi

der

atio

ns

DuSpec Specification Sheet DULUX® AcraTex® Coating System for AFS LOGICWALL™ Building System AcraSkin Stipple Finish

Duspec DULUX AcraTex – AFS WALL AcraPatch High Build Finishing System AcraSkin Stipple Finish Prepared By Shane Langkilde

Page 1 of 2 Duspec No AC1202 Issue No 4 Date 01.05.2012 Approved By Ian Schultz DISCLAIMER: Any advice, recommendation, information, assistance or service provided by any of the divisions of DuluxGroup Products in relation to goods manufactured by it or their use and application is given in good faith and is believed by DuluxGroup to be appropriate and reliable. However, any advice, recommendation, information, assistance or service provided by DuluxGroup is provided without liability or responsibility PROVIDED THAT the foregoing shall not exclude, limit, restrict or modify the right entitlements and remedies conferred upon any person or the liabilities imposed upon DuluxGroup by any condition or warranty implied by Commonwealth, State or Territory Act or ordinance void or prohibiting such exclusion limitation or modification. Coating systems can be expected to perform as indicated on the Duspec Spec Sheet so long as applications and application procedures of the individual products are followed as recommended on the appropriate Product data Sheet The data provided within the Duspec system is correct at the time of publication, however it is the responsibility of those using this information to check that it is current prior to specifying or using any of these coating systems. This specification should be read in conjunction with the Product Datasheets specified within this document. "Dulux" "Berger" "Berger Gold Label" "Hadrian" "Walpamur" "Levene" "AcraTex" are registered trademarks of DuluxGroup Pty Ltd ABN . 67 000 049 427

Substrate: AFS LOGIC WALLTM is an innovative fast track permanent formwork system used as load bearing external and internal wall solutions for both residential & commercial construction. AFS Walling Panels incorporate CSR Cementel Fibre Cement Sheeting – CEMINSEAL WALLBOARD with WATERLOCK technology. Substrate Preparation: Frame detail and panel fixing must comply with relevant building codes and be in strict accordance with substrate manufactures instructions & recommendations. Dulux AcraTex recommends suitable expansion/contraction relief joints be installed at natural building weak points eg in line with openings (window / doors), at all horizontal multilevels, and at all interfaces of different building construction materials and or as defined by Engineer. All fixings must be noncorrosive, suitable for the exposure condition and be in accordance with substrate supplier recommendations. Panel Face & Joint Alignment Panel alignment is critical in all lost formwork systems and specific attention must be given to control of joint & sheeting alignment. Ensure that all joints between panels accurately align and floortofloor alignment ensures a true and flat plane across the elevation. It is the responsibility of the panel installer to ensure all joints or major imperfections, misalignments are filled and sanded true & flush before applying any coatings system.

Remove all surface contaminants such as oil, grease or dirt, dust by hosing suitable detergent /pressure wash before coating.

NOTE : THIS SYSTEM IS SUITABLE WHERE PANEL ALIGNMENT TOLLERANCES ARE ≤4MM

WHERE MAJOR MISALIGNMENT OCCURS, REFER TO ADDITIONAL REMEDIAL RECOMMENDATIONS FOR PRETREATMENT Expansion Joints: CJ’s are best treated before the coating system is applied. The use of a PU Poly Urethane ‘paintable’ Sealant incorporating backing rod in strict accordance with the manufacturer recommendation for use on AFS WallTM should be used in all cases. Select a colour that is complimentary to the final Texture colour. Apply Sealant on completion of the panel installation prior to coating system application.

AFS WALLTM COATING SYSTEM Data Sheet

Application Rate

Recoat ** @250C & 50% RH

JOINT FLUSHING DULUX AcraTex AcraPatch Course L/Shade 19420806

Mix AcraPatch Course with 10% Portland Cement and apply to joint recess and immediately install AcraTex Reinforcing Tape into the wet AcraPatch followed by further AcraPatch to fill the recess. Application of AcraPatch should be ‘wet on wet’ to insure maximum integrity of the joint.

AUSA 2925 12 m2 per Litre 8 hour

BASE COAT DULUX AcraTex – AcraPatch High Build L/Shade 19485841

Mix Ratio 15L AcraTex 500/11 AcraPatch HB; 300mls Portland Cement (5%) Use a power mixing device to mix thoroughly. Ensure that all imperfections are filled, work away from the sun (in shaded areas). Apply with Hawk & Trowel evenly over surface to the thickness 25mm in a single pass. DO NOT overspread the material. Follow up with a light ‘floating’ process to level out the product using a polystyrene or red plastic float

AUDA0440

0.8L / m2 / mm

1x15L AcraPatch HB

will cover 6 m2 @ 2mm thick

16 Hours Protect from rain in

first 24 hours

OPTIONAL PRIMER COAT DULUX AcraTex – AcraPrime Water based Line/Shade 19420902

Used to improve application and workability of texture coat. Apply 1 coat with a 12mm nap roller over the surface ensuring a wet edge is maintained over the application area

AUDA0441 10 m2 / Litre per Coat

4 Hours Protect from rain in

first 24 hours

TEXTURE TOP COAT DULUX AcraTex – AcraSkin L/Shade 19485675

Apply 1 coat with a low profile black Texture Roller LOW PROFILE TEXTURE requires higher material consumption Apply over the surface ensuring a wet edge is maintained over the application area

AUDA1392 23 m2 /Litre 4 Hours

Protect from rain in first 24 hours

FINISHING TOP COAT DULUX AcraTex AcraSkin Line/Shade 19485675

Apply with a 1020 mm nap roller over the surface ensuring a wet edge is maintained over the application area

AUDA1392 4 m2 / Litre 4 Hours

Protect from rain in first 24 hours

Fig. F7.3 - Texture Roller Stipple Finish - Exterior Finishing System - Option B

DuSpec Specification Sheet DULUX® AcraTex® Coating System for AFS LOGICWALL™ Building System AcraSkin Stipple Finish

Duspec DULUX AcraTex – AFS WALL AcraPatch High Build Finishing System AcraSkin Stipple Finish Prepared By Shane Langkilde

Page 1 of 2 Duspec No AC1202 Issue No 4 Date 01.05.2012 Approved By Ian Schultz DISCLAIMER: Any advice, recommendation, information, assistance or service provided by any of the divisions of DuluxGroup Products in relation to goods manufactured by it or their use and application is given in good faith and is believed by DuluxGroup to be appropriate and reliable. However, any advice, recommendation, information, assistance or service provided by DuluxGroup is provided without liability or responsibility PROVIDED THAT the foregoing shall not exclude, limit, restrict or modify the right entitlements and remedies conferred upon any person or the liabilities imposed upon DuluxGroup by any condition or warranty implied by Commonwealth, State or Territory Act or ordinance void or prohibiting such exclusion limitation or modification. Coating systems can be expected to perform as indicated on the Duspec Spec Sheet so long as applications and application procedures of the individual products are followed as recommended on the appropriate Product data Sheet The data provided within the Duspec system is correct at the time of publication, however it is the responsibility of those using this information to check that it is current prior to specifying or using any of these coating systems. This specification should be read in conjunction with the Product Datasheets specified within this document. "Dulux" "Berger" "Berger Gold Label" "Hadrian" "Walpamur" "Levene" "AcraTex" are registered trademarks of DuluxGroup Pty Ltd ABN . 67 000 049 427

Substrate: AFS LOGIC WALLTM is an innovative fast track permanent formwork system used as load bearing external and internal wall solutions for both residential & commercial construction. AFS Walling Panels incorporate CSR Cementel Fibre Cement Sheeting – CEMINSEAL WALLBOARD with WATERLOCK technology. Substrate Preparation: Frame detail and panel fixing must comply with relevant building codes and be in strict accordance with substrate manufactures instructions & recommendations. Dulux AcraTex recommends suitable expansion/contraction relief joints be installed at natural building weak points eg in line with openings (window / doors), at all horizontal multilevels, and at all interfaces of different building construction materials and or as defined by Engineer. All fixings must be noncorrosive, suitable for the exposure condition and be in accordance with substrate supplier recommendations. Panel Face & Joint Alignment Panel alignment is critical in all lost formwork systems and specific attention must be given to control of joint & sheeting alignment. Ensure that all joints between panels accurately align and floortofloor alignment ensures a true and flat plane across the elevation. It is the responsibility of the panel installer to ensure all joints or major imperfections, misalignments are filled and sanded true & flush before applying any coatings system.

Remove all surface contaminants such as oil, grease or dirt, dust by hosing suitable detergent /pressure wash before coating.

NOTE : THIS SYSTEM IS SUITABLE WHERE PANEL ALIGNMENT TOLLERANCES ARE ≤4MM

WHERE MAJOR MISALIGNMENT OCCURS, REFER TO ADDITIONAL REMEDIAL RECOMMENDATIONS FOR PRETREATMENT Expansion Joints: CJ’s are best treated before the coating system is applied. The use of a PU Poly Urethane ‘paintable’ Sealant incorporating backing rod in strict accordance with the manufacturer recommendation for use on AFS WallTM should be used in all cases. Select a colour that is complimentary to the final Texture colour. Apply Sealant on completion of the panel installation prior to coating system application.

AFS WALLTM COATING SYSTEM Data Sheet

Application Rate

Recoat ** @250C & 50% RH

JOINT FLUSHING DULUX AcraTex AcraPatch Course L/Shade 19420806

Mix AcraPatch Course with 10% Portland Cement and apply to joint recess and immediately install AcraTex Reinforcing Tape into the wet AcraPatch followed by further AcraPatch to fill the recess. Application of AcraPatch should be ‘wet on wet’ to insure maximum integrity of the joint.

AUSA 2925 12 m2 per Litre 8 hour

BASE COAT DULUX AcraTex – AcraPatch High Build L/Shade 19485841

Mix Ratio 15L AcraTex 500/11 AcraPatch HB; 300mls Portland Cement (5%) Use a power mixing device to mix thoroughly. Ensure that all imperfections are filled, work away from the sun (in shaded areas). Apply with Hawk & Trowel evenly over surface to the thickness 25mm in a single pass. DO NOT overspread the material. Follow up with a light ‘floating’ process to level out the product using a polystyrene or red plastic float

AUDA0440

0.8L / m2 / mm

1x15L AcraPatch HB

will cover 6 m2 @ 2mm thick

16 Hours Protect from rain in

first 24 hours

OPTIONAL PRIMER COAT DULUX AcraTex – AcraPrime Water based Line/Shade 19420902

Used to improve application and workability of texture coat. Apply 1 coat with a 12mm nap roller over the surface ensuring a wet edge is maintained over the application area

AUDA0441 10 m2 / Litre per Coat

4 Hours Protect from rain in

first 24 hours

TEXTURE TOP COAT DULUX AcraTex – AcraSkin L/Shade 19485675

Apply 1 coat with a low profile black Texture Roller LOW PROFILE TEXTURE requires higher material consumption Apply over the surface ensuring a wet edge is maintained over the application area

AUDA1392 23 m2 /Litre 4 Hours

Protect from rain in first 24 hours

FINISHING TOP COAT DULUX AcraTex AcraSkin Line/Shade 19485675

Apply with a 1020 mm nap roller over the surface ensuring a wet edge is maintained over the application area

AUDA1392 4 m2 / Litre 4 Hours

Protect from rain in first 24 hours

DULUX AcraTex - AFS LOGICWALL AcraPatch High Build Finishing SystemAcraSkin Stipple Finish

AFS LOGICWALL COATING SYSTEM

It is the responsibility of the panel installer or coatings applicator, to ensure all joints or major imperfections, misalignments are filled and sanded true & flush before applying any coatings system.

F7 Finishing Systems Overview continued

F

Ext

erna

l Des

ign

Con

side

ratio

ns

F

Ext

erna

l Des

ign

Con

side

ratio

ns

a f s l o g i c w a l l ® d e s i g n e r 2 0 1 9 133

Page 14: F External Design Considerations - Smart Permanent Formwork

116DESIGNER 2012 WALLING SOLUTIONS

F

E

xter

nal D

esig

n C

onsi

der

atio

ns

DuSpec Specification Sheet DULUX® AcraTex® Coating System for AFS LOGICWALL™ Building System AcraSkin Stipple Finish

Duspec DULUX AcraTex – AFS WALL AcraPatch High Build Finishing System AcraSkin Stipple Finish Prepared By Shane Langkilde

Page 2 of 2 Duspec No AC1202 Issue No 4 Date 01.05.2012 Approved By Ian Schultz DISCLAIMER: Any advice, recommendation, information, assistance or service provided by any of the divisions of DuluxGroup Products in relation to goods manufactured by it or their use and application is given in good faith and is believed by DuluxGroup to be appropriate and reliable. However, any advice, recommendation, information, assistance or service provided by DuluxGroup is provided without liability or responsibility PROVIDED THAT the foregoing shall not exclude, limit, restrict or modify the right entitlements and remedies conferred upon any person or the liabilities imposed upon DuluxGroup by any condition or warranty implied by Commonwealth, State or Territory Act or ordinance void or prohibiting such exclusion limitation or modification. Coating systems can be expected to perform as indicated on the Duspec Spec Sheet so long as applications and application procedures of the individual products are followed as recommended on the appropriate Product data Sheet The data provided within the Duspec system is correct at the time of publication, however it is the responsibility of those using this information to check that it is current prior to specifying or using any of these coating systems. This specification should be read in conjunction with the Product Datasheets specified within this document. "Dulux" "Berger" "Berger Gold Label" "Hadrian" "Walpamur" "Levene" "AcraTex" are registered trademarks of DuluxGroup Pty Ltd ABN . 67 000 049 427

Important Notes:

Coatings should be applied in full accordance with relative product Technical and Applicational data sheets. This system is recommended where panel misalignment is NOT greater than 4mm. Refer to Remedial Specification recommendations where panel misalignment is greater than 4mm.

Practical spreading rates will vary from quoted theoretical figures depending on substrate porosity, surface roughness, misalignment, overspray losses, application methods and environmental conditions (eg wind).

Protect from rain and frost for 24 hours when apply at the recommended spread rate. Dry times apply to a single coat at recommended spread rate and at 25oC and 50% Relative Humidity Allow longer times under cool, moist, or still conditions and or when applied at high film builds.

Do not apply paint if Relative Humidity is above 85% or temperature is within 3°C of Dew Point. Do not apply if the surface temperature is greater than 40°C or below 10°C, or likely to fall below 10°C during the application or drying period.

When using Bright Reds, Oranges, Blues and Yellows or where very light colours are applied over highly contrasting colours an extra coat maybe required.

At Commencement of coating system application to the substrate it shall be deemed that the Applicator has certified that the surface which it is to be applied to is fit receive the specified coating(s) system. When the Applicator is preparing the site sample for approval he should advise the Project Superintendent if the substrate condition is not of sufficient standard to produce the specified finish.

Where possible avoid dark colours these will give raise to much higher surface temperature that may cause addition thermal stress and cooling demand to the building envelope and/ or require extra engineering considerations (Greater building costs). Consult Dulux on the potential to use InfraCOOL Heat Reflective Coatings that will keep the surface cooler.

The coastal area is considered a marine environment and as such salt potentially can shorten the life of the coating systems. Care needs to be taken to wash down all areas twice. Once to remove surface contaminants, and raise salts to the surface and then secondly to remove these salts. Due to the locality, Weather conditions and lag time between applications of the coating system it may require the need to wash again, between coats.

A DULUX warranty can be provided on request when the full AcraTex system is applied by a DULUX AcraTex trained applicator, according to specification, & at the specified spreading rates, & to the surface preparation details described in the DULUX AcraTex Specification Manual.

The dynamics of the substrate are outside the control of Dulux Australia and as such joint deformation or cracking is excluded from warranty terms. Refer warranty document for full terms.

Glancing light Joints and panel deformation may be clearly evident under glancing light, casting visible shadows of the minute and uneven projections of the joints. Glancing light is light that is nearly parallel to the surface of the wall and casts visible shadows and uneven projections of the joints. Just like rendered masonry/ Jointed system any uneven projections will be highlighted and as such are outside the control / scope of this specification.

When using this specification, the Applicator shall maintain records in accordance with AS3894 Parts 10, 11 and 12 and others as required by the Project Manager. These records shall be made available for inspection at any time by the Project Manager or authorised representative and submitted to the Principal Contractor upon completion of work.

Fig. F7.3 - Texture Roller Stipple Finish - Exterior Finishing System - Option B continued

DuSpec Specification Sheet DULUX® AcraTex® Coating System for AFS LOGICWALL™ Building System AcraSkin Stipple Finish

Duspec DULUX AcraTex – AFS WALL AcraPatch High Build Finishing System AcraSkin Stipple Finish Prepared By Shane Langkilde

Page 2 of 2 Duspec No AC1202 Issue No 4 Date 01.05.2012 Approved By Ian Schultz DISCLAIMER: Any advice, recommendation, information, assistance or service provided by any of the divisions of DuluxGroup Products in relation to goods manufactured by it or their use and application is given in good faith and is believed by DuluxGroup to be appropriate and reliable. However, any advice, recommendation, information, assistance or service provided by DuluxGroup is provided without liability or responsibility PROVIDED THAT the foregoing shall not exclude, limit, restrict or modify the right entitlements and remedies conferred upon any person or the liabilities imposed upon DuluxGroup by any condition or warranty implied by Commonwealth, State or Territory Act or ordinance void or prohibiting such exclusion limitation or modification. Coating systems can be expected to perform as indicated on the Duspec Spec Sheet so long as applications and application procedures of the individual products are followed as recommended on the appropriate Product data Sheet The data provided within the Duspec system is correct at the time of publication, however it is the responsibility of those using this information to check that it is current prior to specifying or using any of these coating systems. This specification should be read in conjunction with the Product Datasheets specified within this document. "Dulux" "Berger" "Berger Gold Label" "Hadrian" "Walpamur" "Levene" "AcraTex" are registered trademarks of DuluxGroup Pty Ltd ABN . 67 000 049 427

Important Notes:

Coatings should be applied in full accordance with relative product Technical and Applicational data sheets. This system is recommended where panel misalignment is NOT greater than 4mm. Refer to Remedial Specification recommendations where panel misalignment is greater than 4mm.

Practical spreading rates will vary from quoted theoretical figures depending on substrate porosity, surface roughness, misalignment, overspray losses, application methods and environmental conditions (eg wind).

Protect from rain and frost for 24 hours when apply at the recommended spread rate. Dry times apply to a single coat at recommended spread rate and at 25oC and 50% Relative Humidity Allow longer times under cool, moist, or still conditions and or when applied at high film builds.

Do not apply paint if Relative Humidity is above 85% or temperature is within 3°C of Dew Point. Do not apply if the surface temperature is greater than 40°C or below 10°C, or likely to fall below 10°C during the application or drying period.

When using Bright Reds, Oranges, Blues and Yellows or where very light colours are applied over highly contrasting colours an extra coat maybe required.

At Commencement of coating system application to the substrate it shall be deemed that the Applicator has certified that the surface which it is to be applied to is fit receive the specified coating(s) system. When the Applicator is preparing the site sample for approval he should advise the Project Superintendent if the substrate condition is not of sufficient standard to produce the specified finish.

Where possible avoid dark colours these will give raise to much higher surface temperature that may cause addition thermal stress and cooling demand to the building envelope and/ or require extra engineering considerations (Greater building costs). Consult Dulux on the potential to use InfraCOOL Heat Reflective Coatings that will keep the surface cooler.

The coastal area is considered a marine environment and as such salt potentially can shorten the life of the coating systems. Care needs to be taken to wash down all areas twice. Once to remove surface contaminants, and raise salts to the surface and then secondly to remove these salts. Due to the locality, Weather conditions and lag time between applications of the coating system it may require the need to wash again, between coats.

A DULUX warranty can be provided on request when the full AcraTex system is applied by a DULUX AcraTex trained applicator, according to specification, & at the specified spreading rates, & to the surface preparation details described in the DULUX AcraTex Specification Manual.

The dynamics of the substrate are outside the control of Dulux Australia and as such joint deformation or cracking is excluded from warranty terms. Refer warranty document for full terms.

Glancing light Joints and panel deformation may be clearly evident under glancing light, casting visible shadows of the minute and uneven projections of the joints. Glancing light is light that is nearly parallel to the surface of the wall and casts visible shadows and uneven projections of the joints. Just like rendered masonry/ Jointed system any uneven projections will be highlighted and as such are outside the control / scope of this specification.

When using this specification, the Applicator shall maintain records in accordance with AS3894 Parts 10, 11 and 12 and others as required by the Project Manager. These records shall be made available for inspection at any time by the Project Manager or authorised representative and submitted to the Principal Contractor upon completion of work.

F7 Finishing Systems Overview continued

F

Ext

erna

l Des

ign

Con

side

ratio

ns

a f s l o g i c w a l l ® d e s i g n e r 2 0 1 9 134

Page 15: F External Design Considerations - Smart Permanent Formwork

117WALLING SOLUTIONS DESIGNER 2012

F

E

xter

nal D

esig

n C

onsi

der

atio

ns

Fig. F7.4 - AFS Approved Dulux AcraTex Recommendation - Remediation for Misaligned Panels

AFS FINISHING SYSTEMS 01.05.2012 Page 6 of 10

2.3 SUPPLEMENTARY HIGH BUILD (MISALIGNMENT) REMEDIAL ADVICE F7 Finishing Systems Overview continued

DULUX AcraTex - AFS LOGICWALL AcraPatch High Build Finishing SystemCoventry Coarse Trowel Applied Finish

F

Ext

erna

l Des

ign

Con

side

ratio

ns

F

Ext

erna

l Des

ign

Con

side

ratio

ns

a f s l o g i c w a l l ® d e s i g n e r 2 0 1 9 135

Page 16: F External Design Considerations - Smart Permanent Formwork

118DESIGNER 2012 WALLING SOLUTIONS

F

E

xter

nal D

esig

n C

onsi

der

atio

ns

Fig. F7.5 - Dulux Material Warranty - (Project Specific)

10 Year Warranty Example

Dulux AcraTex warrants its products and systems in accordance with its documented Warranty procedures and pursuant to Registered Applicators providing co-workmanship warranties ensuring correct and proper installation in full accordance with approved Dulux recommendations:

10 Year Dulux AcraTex Material Warranty is applicable on approved system installations incorporating (1) final Weatherproofing AcraShield or AcraSkin Topcoat application.

15 year Dulux AcraTex Material Warranty is applicable on approved system installations incorporating (2) final Weatherproofing AcraShield or AcraSkin Topcoat applications.

DULUX® AcraTex® MATERIALS WARRANTY Project Specification for AFS LOGICWALL™ Building System

Dulux AcraTex AFS LOGICWALL Coating System Warranty

Page 1 of 2

Project Name

Project Address

Surface Area Application Date

Dulux Specification No

Applicator

SUBSTRATE AFS LOGIC WALL STRUCTUAL WALLING SYSTEM Dulux’s warranty in respect of the installed Dulux products in accordance with the nominated Duspec Coating Specification is made up of the terms set out expressly in this document (the Warranty). The benefits of the Warranty are in addition to other rights and remedies under any applicable law. The Warranty Dulux warrants to the Customer that the Dulux products in accordance with the nominated Duspec Coating Specification as stated above, will comply with the relevant Dulux products performance specification(s) and will retain its film integrity and not peel or suffer deterioration due to faulty formulation or manufacture. The Warranty applies for [10] years [from the date of purchase]. If, subject to the terms of the Warranty, the products do not comply with the Dulux Specification(s), Dulux will:

• replace the installed system or supply an equivalent system; • repair the installed system; • pay the cost of having the installed system repaired; or • refund the price paid for the installed system.

In these circumstances, Dulux will have full discretion to choose which of the above actions are undertaken to remedy the situation. The Warranty is personal to the Customer and supersedes any and all other prior agreements and understandings between the parties in relation to its subject matter. Limitations of the Warranty Dulux will not be liable under the Warranty if the installation of Dulux products is not in strict accordance with the instructions provided by or available from Dulux including the Specification; Dulux will not be liable under the Warranty if the substrate on which the system is installed to: is not of a standard and fitness meeting all statutory requirements and building code standards; or has not been prepared strictly in accordance with the instructions provided by or available from Dulux including the Specification; Dulux will not be liable under the Warranty for any loss or damage wholly or partly caused by one or more of: hydrostatic pressure, settling, movement, cracking, lifting, peeling, flaking, failure or other deterioration of the substrate or previous coating or non compliance products; or corrosion, ingress of moisture or other contaminants, maltreatment, excessive wear/tear, staining or discolouration; or faulty design and / or construction of the building; or defective products manufactured by a third party and supplied or specified by Dulux provided that Dulux has notified Customer that the product is a third party product; or without limitation any other cause outside the reasonable control of Dulux; Dulux will not be liable under the Warranty if another non compliance product(s) or coating has been applied over the coating system;

DULUX® AcraTex® MATERIALS WARRANTY Project Specification for AFS LOGICWALL™ Building System

Dulux AcraTex AFS LOGICWALL Coating System Warranty

Page 2 of 2

Dulux will not be liable under the Warranty unless the Customer makes a claim pursuant to the procedure set out in this Warranty; Dulux will not be liable under the Warranty unless the Applicator has signed the Applicator’s Confirmation below; Dulux will not be liable under the Warranty for any consequential or indirect loss of any kind or loss of income, profit, business, goodwill or reputation arising out of or in any way connected with the sale or application of the coating system; and Except as expressly provided to the contrary in the Warranty, Dulux will be under no liability in respect to any loss or damage howsoever caused and whether arising directly or indirectly out of negligence or otherwise. Making a claim under the Warranty The Customer must give Dulux written notice of any claim pursuant to the Warranty within fourteen (14) days of any defect coming to the Customer’s notice and within ninety (90) days of the defect becoming apparent. The Customer must contact Dulux by : post: Dulux AcraTex, 1 Jeanes Street Beverley, SA, 5009 , or email: [email protected]. The Customer must show proof of purchase and bear all expenses incurred in making a claim. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. Dulux Warranty Confirmation & Registration

Dated this day of Warranty Number

Signed on behalf of Dulux

Name

Position

Applicator’s Confirmation The Applicator hereby confirms that the Dulux products in accordance with the nominated Duspec Coating Specification have been installed to the Project in strict accordance with the specification and instructions provided by or available from Dulux including the Dulux Specification, and that the Applicator will be responsible for any loss or damage caused or contributed to by its faulty application. Application Company Company

Registration No Signed on behalf of Applicator

Name

Position

**IMPORTANT: Please note the Warranty is Invalid if a Customer’s Application signed copy is not returned to

Dulux AcraTex at 1 Jeanes St, Beverly SA, 5009 or the Account Manager responsible for the account within 30 working days of Dulux Registration

F7 Finishing Systems Overview continued

118DESIGNER 2012 WALLING SOLUTIONS

F

E

xter

nal D

esig

n C

onsi

der

atio

ns

Fig. F7.5 - Dulux Material Warranty - (Project Specific)

10 Year Warranty Example

Dulux AcraTex warrants its products and systems in accordance with its documented Warranty procedures and pursuant to Registered Applicators providing co-workmanship warranties ensuring correct and proper installation in full accordance with approved Dulux recommendations:

10 Year Dulux AcraTex Material Warranty is applicable on approved system installations incorporating (1) final Weatherproofing AcraShield or AcraSkin Topcoat application.

15 year Dulux AcraTex Material Warranty is applicable on approved system installations incorporating (2) final Weatherproofing AcraShield or AcraSkin Topcoat applications.

DULUX® AcraTex® MATERIALS WARRANTY Project Specification for AFS LOGICWALL™ Building System

Dulux AcraTex AFS LOGICWALL Coating System Warranty

Page 1 of 2

Project Name

Project Address

Surface Area Application Date

Dulux Specification No

Applicator

SUBSTRATE AFS LOGIC WALL STRUCTUAL WALLING SYSTEM Dulux’s warranty in respect of the installed Dulux products in accordance with the nominated Duspec Coating Specification is made up of the terms set out expressly in this document (the Warranty). The benefits of the Warranty are in addition to other rights and remedies under any applicable law. The Warranty Dulux warrants to the Customer that the Dulux products in accordance with the nominated Duspec Coating Specification as stated above, will comply with the relevant Dulux products performance specification(s) and will retain its film integrity and not peel or suffer deterioration due to faulty formulation or manufacture. The Warranty applies for [10] years [from the date of purchase]. If, subject to the terms of the Warranty, the products do not comply with the Dulux Specification(s), Dulux will:

• replace the installed system or supply an equivalent system; • repair the installed system; • pay the cost of having the installed system repaired; or • refund the price paid for the installed system.

In these circumstances, Dulux will have full discretion to choose which of the above actions are undertaken to remedy the situation. The Warranty is personal to the Customer and supersedes any and all other prior agreements and understandings between the parties in relation to its subject matter. Limitations of the Warranty Dulux will not be liable under the Warranty if the installation of Dulux products is not in strict accordance with the instructions provided by or available from Dulux including the Specification; Dulux will not be liable under the Warranty if the substrate on which the system is installed to: is not of a standard and fitness meeting all statutory requirements and building code standards; or has not been prepared strictly in accordance with the instructions provided by or available from Dulux including the Specification; Dulux will not be liable under the Warranty for any loss or damage wholly or partly caused by one or more of: hydrostatic pressure, settling, movement, cracking, lifting, peeling, flaking, failure or other deterioration of the substrate or previous coating or non compliance products; or corrosion, ingress of moisture or other contaminants, maltreatment, excessive wear/tear, staining or discolouration; or faulty design and / or construction of the building; or defective products manufactured by a third party and supplied or specified by Dulux provided that Dulux has notified Customer that the product is a third party product; or without limitation any other cause outside the reasonable control of Dulux; Dulux will not be liable under the Warranty if another non compliance product(s) or coating has been applied over the coating system;

DULUX® AcraTex® MATERIALS WARRANTY Project Specification for AFS LOGICWALL™ Building System

Dulux AcraTex AFS LOGICWALL Coating System Warranty

Page 2 of 2

Dulux will not be liable under the Warranty unless the Customer makes a claim pursuant to the procedure set out in this Warranty; Dulux will not be liable under the Warranty unless the Applicator has signed the Applicator’s Confirmation below; Dulux will not be liable under the Warranty for any consequential or indirect loss of any kind or loss of income, profit, business, goodwill or reputation arising out of or in any way connected with the sale or application of the coating system; and Except as expressly provided to the contrary in the Warranty, Dulux will be under no liability in respect to any loss or damage howsoever caused and whether arising directly or indirectly out of negligence or otherwise. Making a claim under the Warranty The Customer must give Dulux written notice of any claim pursuant to the Warranty within fourteen (14) days of any defect coming to the Customer’s notice and within ninety (90) days of the defect becoming apparent. The Customer must contact Dulux by : post: Dulux AcraTex, 1 Jeanes Street Beverley, SA, 5009 , or email: [email protected]. The Customer must show proof of purchase and bear all expenses incurred in making a claim. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. Dulux Warranty Confirmation & Registration

Dated this day of Warranty Number

Signed on behalf of Dulux

Name

Position

Applicator’s Confirmation The Applicator hereby confirms that the Dulux products in accordance with the nominated Duspec Coating Specification have been installed to the Project in strict accordance with the specification and instructions provided by or available from Dulux including the Dulux Specification, and that the Applicator will be responsible for any loss or damage caused or contributed to by its faulty application. Application Company Company

Registration No Signed on behalf of Applicator

Name

Position

**IMPORTANT: Please note the Warranty is Invalid if a Customer’s Application signed copy is not returned to

Dulux AcraTex at 1 Jeanes St, Beverly SA, 5009 or the Account Manager responsible for the account within 30 working days of Dulux Registration

F7 Finishing Systems Overview continued

F

Ext

erna

l Des

ign

Con

side

ratio

ns

a f s l o g i c w a l l ® d e s i g n e r 2 0 1 9 136

Page 17: F External Design Considerations - Smart Permanent Formwork

119WALLING SOLUTIONS DESIGNER 2012

F

E

xter

nal D

esig

n C

onsi

der

atio

ns

F8 Cladding Systems

F9 Durability

AFS LOGICWALL® provides an effective structural substrate for a range of cladding systems such as Vitrabond and CSR Cemintel Territory Series – prefinished fibrous cement composite panel.

Cladding systems such as these offer the building designer greater choice and flexibility when designing with AFS LOGICWALL®. In particular the CSR Cemintel Designer Series offers:

� Unique aesthetic appeal, which is lightweight and durable. � An innovative fixing system, which rapidly reduces

installation time.� A multi layered coating system designed for long lasting

performance� Texture and depth of colour making it suitable for use on

existing brick or fibre cement facades.� Available in a variety of textures and colours.

1. Introduction

The ultimate durability of any building system relies on appropriateness of design and accuracy of construction methodology together with the performance of individual components and compatibility of related components

The durability and longevity of the exterior façade is heavily influenced by the compatibility of the fi nishing and weatherproofing systems with the structural dynamics of the AFS LOGICWALL® fibre cement faced, solid masonry core, panelized and flush jointed system.

The exterior façade of AFS LOGICWALL® comprises a fibre cement face incorporating a special water block technology which limits water penetrating into the sheet through the construction phase and provides a stable surface for the installation of the Dulux AcraTex Jointing, Levelling – Texture and Weatherproofing Coatings system.

2. Movement Control

Failure to accommodate for normal masonry expansion and contraction in accordance with design specification will induce excessive joint stress and potential joint cracking and breakdown on the weatherproofing barrier.

For further information on Designer Series Facade systems contact the AFS Sales Office - 1300 727 237.

Best practice defines s uitable e xpansion/contraction r elief joints be installed at natural building weak points (eg in line with openings (window / doors), at all horizontal multi-levels, and at all interfaces of different building construction materials) as defined by the engineer.

Flush jointing of panels (other than at defined movement joints) is a critical aspect of the façade system and requires specific attention. Rigid, cementitious jointing or render systems are not recommended and will limit system performance.

3. Weather Proofing

The Dulux AcraTex – AFS LOGICWALL® Coating System conforms to AS4548 Long Life Coatings for Concrete and Masonry.

Long term performance of the Weatherproofing Envelope requires :

� Low water transmission � Adequate crackbridging capability to maintain a continuous

film under dynamic stress resulting from thermal expansion and contraction and normal joint movement� Adequate water vapour permeability to allow for normal

moisture vapour movement preventing vapour pressure from under the film to cause blistering

DULUX® AcraTex® MATERIALS WARRANTYProject Specification for AFS LOGICWALL™ Building System

Dulux AcraTex AFS LOGICWALL Coating System WarrantyPage 2 of 2

Dulux will not be liable under the Warranty unless the Customer makes a claim pursuant to the procedureset out in this Warranty;

Dulux will not be liable under the Warranty unless the Applicator has signed the Applicator’s Confirmation below;

Dulux will not be liable under the Warranty for any consequential or indirect loss of any kind or loss ofincome, profit, business, goodwill or reputation arising out of or in any way connected with the sale orapplication of the coating system; andExcept as expressly provided to the contrary in the Warranty, Dulux will be under no liability in respect to any loss or damage howsoever caused and whether arising directly or indirectly out of negligence orotherwise.

Making a claim under the WarrantyThe Customer must give Dulux written notice of any claim pursuant to the Warranty within fourteen (14)days of any defect coming to the Customer’s notice and within ninety (90) days of the defect becomingapparent.

The Customer must contact Dulux by :post: Dulux AcraTex, 1 Jeanes Street Beverley, SA, 5009 , or email: [email protected] Customer must show proof of purchase and bear all expenses incurred in making a claim.

Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonablyforeseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods failto be of acceptable quality and the failure does not amount to a major failure.

Dulux Warranty Confirmation & Registration

Dated this day of WarrantyNumber Signed

on behalf of Dulux

Name

Position

Applicator’s ConfirmationThe Applicator hereby confirms that the Dulux products in accordance with the nominated DuspecCoating Specification have been installed to the Project in strict accordance with the specification andinstructions provided by or available from Dulux including the Dulux Specification, and that the Applicatorwill be responsible for any loss or damage caused or contributed to by its faulty application.

ApplicationCompany Company

Registration NoSigned on behalf of Applicator

Name

Position

**IMPORTANT:Please note the Warranty is Invalid if a Customer’s Application signed copy is not returned to

Dulux AcraTex at 1 Jeanes St, Beverly SA, 5009or the Account Manager responsible for the account within 30 working days of Dulux Registration

F

Ext

erna

l Des

ign

Con

side

ratio

ns

F

Ext

erna

l Des

ign

Con

side

ratio

ns

a f s l o g i c w a l l ® d e s i g n e r 2 0 1 9 137

Page 18: F External Design Considerations - Smart Permanent Formwork

120DESIGNER 2012 WALLING SOLUTIONS

F

E

xter

nal D

esig

n C

onsi

der

atio

ns

4. Maintenance

Durability and longevity of the façade system requires periodic inspection and maintenance to identify and correct deleterious conditions.

Inspections should include examination of any abnormal coating staining or water run off concentration, flashings and seals as well as attention to potential moisture issues such as ground water drainage or build up of soils or other wastes against the façade face.

Specific attention should be given to control jointing failure or signs of excess movement which should be repaired immediately to prevent water ingress and potential surrounding coating issues.

Early signs of moulds or mildew (I.e. organic growth) must be addressed to prevent spread of the spoilage. Organic growths occur typically due the presence of excess moisture and nutrient. (I.e. dirt or mould spores deposited on the surface). The applied coating cannot “grow” mould. Identification of organic growth requires correction of contributory issue and cleaning of the surface including a suitable mould-mildew agent.

For optimum aesthetics and to extend system lifecycle, it is recommended to annually wash down the exterior surface using a suitable mild detergent solution and medium pressure wash (i.e. <1000 psi).

5. Extending Lifestyle Performance

Ultimate lifecycle costs of the total façade system are optimised when Dulux AcraTex AcraShield (I.e the specified final weatherproofing barrier coat) is reinstalled after 10-15 years.

Lifecycle analysis confirms a 10-15 year recoating window together with periodic maintenance of the façade system prior to deteriation to be the most effective cycle to deliver optimum performance, aesthetics and cost efficiency.

Dulux AcraTex Systems Warranties can be extended to

form lifecycle warranties on agreement of Maintenance and Recoating processes using full Dulux AcraTex systems.

The "Lifetime Warranty Process" requires inspection, necessary maintenance & cleaning on routine intervals – typically every 5 years (dependant on location and exposure) by a trained applicator and then subsequent re - top-coating prior to the Warranty Expiration with 2 coats Dulux AcraTex Weatherproofing AcraShield or AcraSkin.

At agreed intervals and/or as required relative to building or site issues, any touch ups (areas of stress/damage) are addressed as Preventative Maintenance. Any Preventative Maintenance required (eg cleaning or repairs not deemed coating failure in according with warranty terms) will be contracted at additional cost.

The “Lifetime Warranty Process” maximises the aesthetic and performance attributes of the facade system and minimises potential repair costs of issues not addressed and which may escalate into costly repairs.

Standard Dulux AcraTex Warranty conditions apply including (but not limited to)

1. Dulux AcraTex Specification Approval2. The Applicator shall, prior to commencement of the works,

submit to Dulux AcraTex the required Warranty RequestForm & secure a project "G" number signed by anauthorised Dulux officer.

3. At the completion of the works the Applicator shallconfirm system installation to specification / Duluxrecommendation, and request the relevant Dulux AcraTexWarranty Document for their client, and submit alignedworkmanship warranties confirming installation tospecification

4. All warranties shall be contingent on the substrate onwhich the coatings system is applied maintains a standardmeeting all building code standards and statutoryrequirements having suffered no deterioration leading topremature coating failure.

Dulux AcraTex and AFS LOGICWALL® Coating System Performance Specification

Water Transmission AS4548.5 Appendix B Less than 10g/24h/m2/kPa

Cyclone Testing (Wind Driven Rain)

ASTM 514 - 90 Zero penetration, 24 hrs

Crack Bridging AS4548.5 Appendix F 1 mm (minimum)

Moisture Vapour Permeability AS4548.5 Appendix F > 50 g /m2 /24h

F

Ext

erna

l Des

ign

Con

side

ratio

ns

a f s l o g i c w a l l ® d e s i g n e r 2 0 1 9 138

Page 19: F External Design Considerations - Smart Permanent Formwork

F Legal Statements

IMPORTANT LEGAL STATEMENTS

Reasonable efforts have been made to ensure the accuracy of this publication; however, any information and data contained herein is subject to change without notice. To ensure the information you are using is correct, AFS recommends you review the latest technical information available on the AFS website www.afswall.com.au, or alternatively call 1300 727 237 to speak to a Technical Representative.

The AFS logo and LOGICWALL® mark are registered trade marks. © 2019 AFS Systems Pty Ltd. No part of this publication may be reproduced in any form or by any means without prior written permission from AFS Systems Pty Ltd. All rights reserved.

DISCLAIMER

1. This technical manual named AFS Designer together with the design tables and associated information related to AFS LOGICWALL® has been prepared by AFS to assist design professionals using AFS LOGICWALL® including without limitation, developers, builders, engineers, architects or quantity surveyors with the design of structural walls.

2. It is the responsibility of the user to ensure that the use of this manual is appropriate and to exercise their own judgment when using this manual.

3. AFS does not accept any responsibility (whether for negligence or otherwise) for any consequence arising from the use or application of this manual.

4. The design and engineering of the structure of any building using AFS LOGICWALL® should only be undertaken by suitability qualified and experienced design professionals, engineers or consultants.

5. The full responsibility for the design, engineering and structural design, and certification of compliance with all relevant Australian Standards, National Construction Code (NCC) and any other statutory requirements at Local, State and Federal levels rest with the design professional, project engineer or project consultants including but not limited to the design engineer, acoustic consultant, energy efficiency consultant, fire engineer and any of their officers, employees, delegates, partners, agents and service providers of any nature.

6. AFS reserves the right to change the specifications of this manual without notice.

7. Please check with AFS that you have the latest version as the manual may be updated from time to time and certain details may change.

8. This disclaimer applies to the extent permitted by law.

DEFINITIONS

The use of the terms ‘AFS LOGICWALL®’ and ‘AFS LOGICWALL® Walls’ throughout the AFS Designer are as follows;

AFS LOGICWALL®: Refers to AFS LOGICWALL® panels as permanent formwork prior to being installed & corefilled with concrete.

AFS LOGICWALL® Walls: Refers to AFS LOGICWALL® walls installed with concrete corefill incorporated.

F

Ext

erna

l Des

ign

Con

side

ratio

ns

F

Ext

erna

l Des

ign

Con

side

ratio

ns

a f s l o g i c w a l l ® d e s i g n e r 2 0 1 9 139

Page 20: F External Design Considerations - Smart Permanent Formwork

1009-Jan-19

IMPORTANT LEGAL INFORMATIONReasonable efforts have been made to ensure the accuracy of this publication; however, any information and data contained herein is subject to change without notice. To ensure the information you are using is correct, AFS recommends you review the latest technical information available on the AFS website www.afsformwork.com.au, or alternatively call 1300 727 237 to speak to a Technical Representative.

The AFS logo and logicwall® mark are registered trade marks. © 2019 AFS Systems Pty Ltd. No part of this publication may be reproduced in any form or by any means without prior written permission from AFS Systems Pty Ltd. All rights reserved.

AFS Systems Pty Ltd110 Airds Road, Minto NSW 2566ABN 45 576 072 788

1300 727 237 afsformwork.com.au