EMD-570

1
EMD-570 Trace Oxygen Transmitter Phone: 1-949-398-2879; Fax: 1-949-315-3622 E-mail: [email protected]; Web: www.sso2.com 4045 E. Guasti Rd. #203, Ontario CA 91761 USA Product Specifications Precision Electrochemical Sensor Technology Backlight Display w/ Auto-Range 5 Standard Analysis Ranges 4-20mA and 0 - 1VDC are Range Locked Compact In-Line Packaging, Small Footprint Specifications: Ranges: 0 - 10/100/1000ppm/1%/25% Accuracy: +/- 2% Full Scale Range* Display: Graphical w/ Backlight Dimensions: 3” x 5” Enclosure: Nylon Top & SS Housing Classification: General Purpose Temperature: 0 - 50 deg C Power: 12 - 24 VDC Signal Output: 4 - 20mA or 0 - 1VDC Response time: T90 in 10 Seconds Sensor: TO2-1x Trace Oxygen Sensor Life: 17—24 months Calibration: Periodically Temperature Compensation: Integral Flow Sensitivity: 1 - 4 SCFH Flow Cell: 1/8” Compression Warranty: 9 Months Sensor Warranty: 12 Months Electronics *Accuracy at constant conditions Optional Accessories: Optional Ranges: Fully Customizable from Factory H3 Flow Through Sensor Housing 1/4” Compression TO2-2x Oxygen Sensor with > 0.5% CO2 Present Applications: “Inquiry for Application Expertise” Inert Glove Box Systems Nitrogen and O2 PSA Generators Laboratories & Universities Beverage Grade CO2 Monitoring Air Separation Plants & Many Others

description

Brochure

Transcript of EMD-570

Page 1: EMD-570

EMD-570 Trace Oxygen Transmitter

Phone: 1-949-398-2879; Fax: 1-949-315-3622E-mail: [email protected]; Web: www.sso2.com4045 E. Guasti Rd. #203, Ontario CA 91761 USA

Product Specifications

Precision Electrochemical Sensor TechnologyBacklight Display w/ Auto-Range5 Standard Analysis Ranges4-20mA and 0 - 1VDC are Range LockedCompact In-Line Packaging, Small Footprint

Specifications:Ranges: 0 - 10/100/1000ppm/1%/25%Accuracy: +/- 2% Full Scale Range*Display: Graphical w/ BacklightDimensions: 3” x 5” Enclosure: Nylon Top & SS HousingClassification: General PurposeTemperature: 0 - 50 deg CPower: 12 - 24 VDCSignal Output: 4 - 20mA or 0 - 1VDCResponse time: T90 in 10 SecondsSensor: TO2-1x Trace OxygenSensor Life: 17—24 monthsCalibration: PeriodicallyTemperature Compensation: IntegralFlow Sensitivity: 1 - 4 SCFHFlow Cell: 1/8” CompressionWarranty: 9 Months SensorWarranty: 12 Months Electronics

*Accuracy at constant conditions

Optional Accessories:• Optional Ranges: Fully Customizable from Factory• H3FlowThroughSensorHousing1/4”Compression• TO2-2xOxygenSensorwith>0.5%CO2Present

Applications:

“Inquiry for Application Expertise”

• InertGloveBoxSystems• NitrogenandO2PSAGenerators• Laboratories&Universities• BeverageGradeCO2Monitoring• AirSeparationPlants