EDS-508A_505A

download EDS-508A_505A

of 3

Transcript of EDS-508A_505A

  • 8/17/2019 EDS-508A_505A

    1/3

  • 8/17/2019 EDS-508A_505A

    2/3email : [email protected] www.moxa.com 2-15

    Total Solutions for Industrial Device Networking

    Dimensions (unit = mm)

    2-15email : [email protected] www.moxa.com

    M an a g e dE th ern e t Swi t ch e s

    Optical Fiber

    * Single mode for EDS-508A and EDS-505A only.

    Power RequirementsInput Voltage: 24 VDC (12 to 45 VDC), redundant dual inputs

    Input Current (@ 24 V): 0.44A (EDS-516A), 0.51A (EDS-516A-MM),0.26A/0.24A (EDS-508A/505A), 0.36A/0.35A (EDS-508A/505A-MM,

    EDS-508A/505A-SS)Connection: Two removable 6-pin terminal blocks

    Overload Current Protection: Present

    Reverse Polarity Protection: Present

    Physical CharacteristicsCasing: IP30 protection, metal case

    Dimensions (W x H x D): 

    EDS-516A series: 94 x 135 x 142.7 mm (3.7 x 5.31 x 5.62 in.)

    EDS-508A/505A series: 80.2 x 135 x 105 mm (3.16 x 5.31 x 4.13 in.)

    Weight: 

    EDS-516A series: 1586 g

    EDS-508A/505A series: 1040 g

    Installation: DIN-Rail mounting, wall mounting (optional kit)

    142.7 94

    Side View Front ViewDIN-Rail Kit Rear View Mounting Kit

    [ EDS-516A series ]

    100BaseFX

    Multi Mode Single ModeSingle Mode,

    80 km

    Wavelength 1300 nm 1310 nm 1550 nm

    Max. TX -10 dBm 0 dBm 0 dBm

    Min. TX -20 dBm -5 dBm -5 dBm

    RX Sensitivity -32 dBm -34 dBm -34 dBmLink Budget 12 dB 29 dB 29 dB

    Typical Distance5 km a

    4 km b40 km c 80 km d

    Saturation -6 dBm -3 dBm -3 dBm

    a. 50/125 µm, 800 MHz*km fiber optic cableb. 62.5/125 µm, 500 MHz*km fiber optic cablec. 9/125 µm, 3.5 PS/(nm*km) fiber optic cabled. 9/125 µm, 19 PS/(nm*km) fiber optic cable

    Environmental LimitsOperating Temperature: 0 to 60°C (32 to 140°F)

    -40 to 75°C (-40 to 167°F) for T models

    Storage Temperature: -40 to 85°C (-40 to 185°F)

    Ambient Relative Humidity: 5 to 95% (non-condensing)

    Regulatory Approvals

    Safety: UL508, UL60950-1, CSA C22.2 No. 60950-1, EN60950-1

    Hazardous Location: UL/cUL Class I, Division 2, Groups A, B, C, and D(EDS-516A Pending); ATEX Class I, Zone 2, Ex nC IIC (Pending)

    Maritime: DNV, GL

    EMI: FCC Part 15, CISPR (EN55022) class A

    EMS: EN61000-4-2 (ESD), level 3 (EDS-508A/505A) / level 2 (EDS-516A)

    EN61000-4-3 (RS), level 3

    EN61000-4-4 (EFT), level 3 (EDS-508A/505A) / level 2 (EDS-516A)

    EN61000-4-5 (Surge), level 3

    EN61000-4-6 (CS), level 3

    EN61000-4-8

    EN61000-4-11

    Shock: IEC 60068-2-27

    Freefall: IEC 60068-2-32

    Vibration: IEC 60068-2-6

    MTBF: EDS-516A series: 247,000 hrs

    EDS-508A series: 339,000 hrs

    EDS-505A series: 352,000 hrs

    Database: Telcordia (Bellcore), GB

    *Please check Moxa’s website for the most up-to-date certification status.

    Warranty5 years (see www.moxa.com/warranty for details)

    E

    D S

     5 0 5A / 5 0 8A / 51 6A

  • 8/17/2019 EDS-508A_505A

    3/3