DRAWING LIST - Engineering...
Transcript of DRAWING LIST - Engineering...
TENDER DOCUMENT
NIT No.: DLI/C&E/WI-675/273A FOR
Tender for „Design, Engineering, Supply, installation, testing and commissioning of „FIRE HYDRANT TYPE FIRE FIGHTING PACKAGE AND ASSOCIATED WORKS‟ for the project of “Augmentation of Fuel and Flux Crushing facilities (Package- 064) of Bhilai Steel Plant, (SAIL)”.
VOLUME – 2C
DRAWING LIST
ENGINEERING PROJECTS (INDIA) LIMITED (A GOVT. OF INDIA ENTERPRISE)
Core-3, Scope Complex, 7, Institutional Area, Lodhi Road, New Delhi-110003
TEL NO: 011-24361666 FAX NO. 011- 24363426
---------------------------------------------------------------------------------------------------------
EPI – New Delhi Volume 2C, Rev. 0 Page 1 of 1
LIST OF DRAWINGS
S.No
Drawing Number
Drawing Description
1 EPI-BSP-064-02-BE 0002A
( 1 Sheet, Rev. 0)
Common General Layout Plan for Fire
Hydrant System
2 EPI-BSP-064-02-BE-02266 (Approved)
( 1 Sheet, Rev. 2)
Schematic Diagram for Fire Hydrant &
MVWS System for Water Based Fire
Fighting System.
MECON LIMITED
7.0 MTPA EXPANSION
BHILAI STEEL PLANT,BHILAI, CHHATTISGARH
CRUSHING FACILITIES (PKG-064)
AUGMENTATION OF FUEL & FLUX
BSP- EPI- 02- 064- 02- 000- 55- BE- 0002A
SHEET 1 OF 1
EPI-BSP- 064- 02- BE- 0002A
COMMON GENERAL LAYOUT PLAN
LK
LK
AK
RCM
FOR TENDER PURPOSE ONLY
JH-1
COKE DEDUSTING UNIT
DEDUSTING
C
O
N
V
.K
11-11
C
O
N
V
.K
1
1
-1
2
COKE BREEZE BUNKER
C
O
N
V
.
K
1
1
-
1
8
60 mm GRIZZLEY SCREENS
30 mm GRIZZLEY SCREENS
COKE CUTTERS
80mm
COKE CRUSHING
C
O
N
V
.. K
11-8
COKE SCREENING STATION.
GRIZZLEY
CHUTES
STATION
LEGEND
TO SINTER PLANT
JH-2
Z17
CONV.K11-9A
15mm VIBRATING SCREEN
EMERGENCY COKE YARD
JH-3
JH-4
JH.-7
SURGE BUNKERS
JH-6
JH-5
JH.-9
JH.-8
JH-10
JH-11
JH-12
JH-13
WAGON LOADING
WAGON LOADING
C
O
N
V
.. K
11-7
CONV.K11-9
CONV.K11-10A
CONV.K11-10
CONV.K11-6A
CONV.K11-6B
CONV.K11-10D
CONV.K11-10C
C
O
N
V
.K
1
1
-1
0
E
CO
NV.K
11-13
CO
NV
.K11-1
4
CONV.K11-15
CONV.K11-15A
CONV.K11-17
C
O
N
V
.K
1
1
-
1
9
C
O
N
V
.K
1
1
-
2
0
C
O
N
V
.
K
1
1
-
2
1
C
O
N
V
.
K
1
1
-
2
2
CONV.C3A-C2
CONV.KA-5
C
O
N
V
.
K
A
-
4
CO
NV
.KA
-3
CONV.KA-2
CONV.KA-1
CONV.K11-6
EXISTING FACILITIES
PROPOSED FACILITIES
C
O
N
V.K
11-2
C
O
N
V
.K
1
1
-1
(B
Y O
TH
ER
S)
(B
Y
O
T
H
E
R
S
)
MODIFICATION OF EXISTING FACILITIES
30 mm VIBRATING SCREENS
CONV.K11-10B
CONV.K11-9B
FUT.CONV
SCREENS
CONV.K11-16
CONV.K11-16A
FLOW DIAGRAM - COKE SORTING PLANT
MANUAL SECTOR
GATE (TYP.)
JH-4 ( EXISTING )
EXISTING COAL
TOWER NO.-1
JH-11A
COAL TOWER NO.-7 COB-II
JH-11B
LEGEND
C
O
N
V
.
Y
1
1
-
2
0
7
C
O
N
V
.
Y
1
1
-
2
0
8
CONV.Y11-206
E
X
IS
T
IN
G
C
O
N
V
.Y
-1
4
E
X
I
S
T
I
N
G
C
O
N
V
.
Y
-
1
5
C
O
N
V
.
Y
1
1
-
2
0
9
RS CONV.Y11-210
RS CONV.Y11-211
EXISTING FACILITIES
PROPOSED FACILITIES
(MODIFICATION)
MODIFICATION
FLOW DIAGRAM - COAL HANDLING
PLANT (COAL TOWER AREA)
SURGE
BIN
VF
BIN
SURGE
SURGE
BIN
VF
RSC-L106 (NEW)
CONV.L-111A
C
O
N
V
.
L
-
1
1
4
A
L115 (Modified)
L120 (Modified)
CONV.L-117
NEW EXTENDED
FLUX SCREENING BUILDING
NEW EXTENSION
VF VF
SCREEN
SCREEN
PRI.
HAMMER
CRUSHER
HAMMER
CRUSHER
SEC.
LEGEND:
BLDG.
EXTN.
9mFOR
DRIVE
IN/OUT
REVERSIBLE CONV.RC-106
DOUBLE ROLL
CRUSHER
CO
NV
.C-107A
C111A
CONV.C-110A
SIZER
MOGENSEN
CONV.C-113A
RC-CK2
BELT FEEDER
ROD MILL
BELT FEEDER
BIN
SURGE
C112A
COKE GRINDING BUILDING
ROD MILL
100m
3
100m
3
100m
3
200m
3
100m
3
75 m
3
200m
3
JH-CK1
JH-CK2
SCREENING BLDG.
CONV.C-106A
JH-CK3
CO
NV
.C-107B
RSC-L118 (NEW)
C
O
N
V
.
C
-
1
0
4
(MODIFIED)
FLOW DIAGRAM - FUEL & FLUX
CO
NV
.K
11-7
CONV. C3A-C1
JH-125
Y+7895.00X+4444.00
LTSS-5
PH
-3
FOR FIRE HYDRANT SYSTEM
PR
OD
UC
ED
B
Y A
N A
UT
OD
ES
K E
DU
CA
TIO
NA
L P
RO
DU
CT
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
PR
OD
UC
ED
B
Y A
N A
UT
OD
ES
K E
DU
CA
TIO
NA
L P
RO
DU
CT