N. Main St. Prairie W. Dallas St. - Houstonpurchasing.houstontx.gov/bids/C24582/Shutter...

16
DESIGN FILE: XXXXXXXX.dwg Crockett St. Washington Ave. I-10 KATY FWY Memorial Dr. Allen Pkwy. W. Dallas St. W. Gray St. Sawyer St. Houston Ave. Elyslan St. N. Main St. Taft St. I-45 GULF FWY 59 EASTEX FWY Louisiana St. Smith St. Fannin St. San Jacinto St. Crawford St. Pease St. Jefferson St. Leeland Ave. Polk St. Prairie Rusk St. Issue for Permit 01.30.2013

Transcript of N. Main St. Prairie W. Dallas St. - Houstonpurchasing.houstontx.gov/bids/C24582/Shutter...

DE

SIG

N F

ILE

: XX

XXXX

XX.d

wg

Crockett St.

Washington Ave.

I-10 KATY FWY

Memorial Dr.

Allen Pkwy.

W. Dallas St.

W. Gray St.

Saw

yer St.

Houston A

ve.

Elyslan S

t.

N. M

ain St.

Taft St.

I-45 GU

LF FWY

59 E

ASTE

X FW

Y

Louis

iana

St.

Smith

St.

Fann

in St

.

San

Jacin

to S

t.

Craw

ford

St.

Pease St.

Jefferson St.Leeland Ave.

Polk St.

PrairieRusk St.

Issue for Permit01.30.2013

1DRAWING SYMBOLS 7 AREA OF WORK 4

CODE ANALYSIS 4

GENERAL INFORMATION

1

PROJECT DESCRIPTION

G.001

AS INDICATED

GENERALINFORMATION

SHEET NO. :

CITY DWG. NO. :

SHEET TITLE :

CHECKED BY :DRAWN BY :

G.F.S. No :

SCALE :

DATE :

REVIEWED :

GENERAL SERVICESDEPARTMENT

PROJECT NAME :

SEAL(S) :

CONSULTANT(S) :

NO. DESCRIPTION

ISSUE LOGDATE

City Hall AnnexHurricane Mitigation Program

Hurricane Shutters

900 Bagby StreetHouston, TX 77002

Architectural Brave/Architecture4617 Montrose Blvd, Suite C230Houston, TX 77006Voice: 713.524.5858Fax: 713.524.5868B/A Project #: 12128Contact: Silvana Micolich

Structural Walter P. Moore1301 McKinney Suite 1100Houston, Texas 77010

Voice: 713.630.7300 Contact: Daron Hester

1 Owner Review06.20.20122 Issue for Bid07.26.20123 Issue for Permit01.30.2013

PERFORATEDPERF

REQUIRED

FLR FLOOR

REQD

FIRE VALVE CABINET

FIRE RETARDANTFACTORY MUTUAL

FOOTING

FIREPROOF

FLOW LINEFLUORESCENT

FULL SIZE

FLASHING

FURRED (ING)FURNISHFOOT (FEET)

FIELD VERIFY

FTG

F.V.FVC

FT

FURRFURN

FLUORFLSHG

FM

FSFRPFFR

FL

REVISIONRETURN

REFER TO

RESILIENT

ROOF TOP UNIT

ROOFING

ROOMRISER

RIGHT OF WAY

RIGHT HAND

ROWR.T.U.

RE:REV

RFG

RESRET

RM

RHRI

EXTERIOR INSULATED FINISH SYSTEM

EW EACH WAYEYE WASH

FIRE CODEFLOOR DRAIN

EXISTINGEXPANSION

EXTERIOREXPOSED

FIRE ALARM

EXHAUST

FIRE HYDRANTFIRE HOSE CABINETFIRE EXTINGUISHER CABINET

FLOORINGFIXTUREFINISH (ED)

FC

FH

FLRGFIXTFIN

FDFECFHC

EXPANEXPEXT

FA

EWSH

EXISTEXH

EXPANSION JOINT

ELEVATORELEVATION

ELECTRICAL

EQUIPMENT

EMERGENCYEXPLOSION PROOF

ELASTIC SHEET ROOFINGELECTRIC WATER COOLERELECTRIC WATER HEATER

ELASTIC (ELASTOMERIC)

EXTERIOR FACE OF BUILDING

EL

EQESR

EWHEWC

EPEQUIP

EMER

EQUAL

EJ

ELEVELECELAS

EA

EIFSEFOB

EACH

PRECASTP/C

QUARRY TILE

RADIUSRETURN AIR GRILLERETURN AIR

RECEPTION

RECESSED

ROOF DRAIN

RECEPTACLERECOMMENDATION

REINFORCING BAR

REFLECTED CEILING PLAN

REINFORCEDREGULATION

RD

RECEPT

REINF

RECEPRECOM

REGREC

REBAR

RCP

R/AGR/A

R

QT

PLASTIC LAMINATEPLASTERPLASTIC

PLYWOODPANEL

PAIRPARKING

PLUMBING

POLISHED

PAVING

PAINTED

PAVEMENTPROPERTY LINE

POUNDS PER SQUARE INCHPOUNDS PER SQUARE FOOT

POLYVINYL CHLORIDE

PRKGPR

PVMTPVGPVC

P.L.

PSF

PTDPSI

PLAMPLASTPLASPLBGPLWDPNLPOL

GUARANTEED MAXIMUM PRICE

HEATING,

INTERNATIONAL BUILDING CODE

MECHANICAL, ELECTRICAL, PLUMBING

NOISE REDUCTION COEFFICIENT

OWNER FURNISHED /

PORTLAND CEMENT PLASTER

OWNER FURNISHED /

INSIDE DIAMETERID

BM BEAM

MANHOLE

CONST CONSTRUCTION

MH

DBL DOUBLE

DIAGONAL

DEFLECTION

DOWNSPOUT

DIAMETERDIMENSION

DISPENSERDEAD LOAD

DISCONNECT

DAMPROOFING

DRINKING FOUNTAIN

DRAWINGDRYWALL FURRING CHANNEL

DMPFG

DTL

DDWGDWC

DSDRDN

DETAIL

DEPTH

DOORDOWN

DIADIM

DISPDL

DISC

DFDIAG

DEFL

CONTRACTORCONTINUOUS

COUNTERSUNKCENTERCASEMENTCORRIDOR

CERAMIC TILE

CORRUGATED

CUBIC YARD

CASED OPENING

CUBIC FOOT (FEET)

CENTER TO CENTER

DRY MARKER BOARD

CT

C-CC.O.

DB

C

CU FTCU YD

CURB

CONTR

CORRUCORR

CTRCSMT

CTSK

CONT

OVERALLOA

OFFICE

ON CENTER (S)OUTSIDE DIAMETER

OPENINGOPPOSITE

OVERHEAD

OUTSIDE AIR

OPPOSITE HAND

PARTITION

OVERFLOW ROOF DRAIN

POUNDS PER CUBIC FOOT

OPNG

PCP

PART

O/A

PCF

OPPORD

OFCI

OPH

OFOI

OFF

OH

OCOD

MINIMUM

MOUNTED

METALMOUNTING

METAL LATHMASONRY OPENING

MISCELLANEOUS

MOISTURE RESISTANT

MULLION

NOMINALNUMBER

NOT IN CONTRACT

NOT TO SCALE

MTL

NRCNTS

MULL

NO. OR #

NICNOM

MINMISC

MTDMTG

MOMR

ML

CER CERAMIC

CAST IRON PIPECONTROL JOINT

CAST IN PLACECOLD FORMED METAL FRAMING

COLUMNCOUNTER

CLOSETCLEAR (ANCE)CEILINGCHALKBOARD

CONCRETE MASONRY UNIT

COMPOSITIONCONCRETECONDITION

COMPRESSIBLE

CONFERENCE

CLT

COMPRESCOMPCONCCONDCONF

COLCNTRCMU

CI PIPECJCKBDCLGCLR

CFMFCIP

BRACKETBASEMENTBETWEEN

BEARINGBOTTOM

CLOSED CIRCUIT TELEVISIONCHALK BOARDCABINET

BACK TO BACKBENCH MARKBOTH FACES

BUILT UP ROOFINGBALLED & BURLAPPED

CEMENT

B-B

CABCBCCTVCEM

B.M.B/F

BSMTBTW

B&BBUR

BOT

BRKTBRG

LEFT HANDLH

LOCKER(S)

LIGHT

LINEAR

LIVE LOAD

MACHINE

MASONRY

MAXIMUMMATERIAL

MAINTENANCE

LIGHTWEIGHT

MEMBRANEMECHANICAL

MANUFACTURER

MACHINE BOLT

MAINT

MEMBMEPMFR

MATL

MECH

MAX

MAS

MB

LCKR

LWT

LIN

MACH

LTLL

INSULATION (ING)

INCLUDEINFORMATION

INCHINSIDE PIPE SIZE

INTERIOR

JOINTJOISTJANITOR

LAVATORYLAMINATE (D)

INCANDESCENT

LENGTH

LAMLAVLGTH

JSTJAN

JT

INCL

INSULINFO

INCAND

IPS

INTIN

AMERICAN WITH DISABILITIES ACT

ARCH ARCHITECT (URAL)AS SHOWNASPHALTATTENUATION (ING)

AUXILIARY

BOARD

BLOCKINGBUILDING

AVENUEAVERAGE

AUDIO VISUALAIR CONDITIONING

AUTOMATIC

A/C

BLDGBLKGBLK

A/V

BD

BLOCK

AUTO

AVGAVEAUX

A/S

ATNASPH

ANCHOR BOLTACOUSTICAL

ADJUSTABLEADJACENTABOVE FINISHED FLOOR

ANODIZEDALUMINUMALTERNATE

ACCES DOOR

AGGREGATE

APPROXIMATELYACCESS PANEL

AIR HANDLING UNIT

ABUSE RESISTANT

AGGAFF

APPROXANOD

APA-R

ALTAHU

ALUM

ADJUST.

ACOUS

ADA

ADJ

AB

AD

HOSE BIBBHB

HANDICAPPEDHOLLOW CORE

HARDWOOD

HOUR

HALF FULL SIZE

HORSEPOWERHORIZONTALHOLLOW METAL

HEAD

HEIGHT

HYDRANT

HARDWARE

HORIZ

HVAC

HYD

IBC

HRHT

HP

HDCP

HDWRHDWD

HMHFSHD

HC

GAGEGALLONGALVANIZED

GRADE, GRADINGGENERAL CONTRACTOR

GROUND

GALVANIZED IRONGLASS, GLAZING

GYPSUM

GLASS MESH MORTAR UNIT

GENERALGI

GMPGMMU

GYPGR

GL

GALGALV

GEN

GA

GDGC

T.O. TOP OF

W/I WITHIN

W/I

XFMR

W/OWPW/

WORK POINT

TRANSFORMER

WITHIN

WITHOUT

WITH

TELEPHONE TERMINAL CABINET

UNDERWRITERS LABORATORYUNLESS NOTED OTHERWISE

VINYL COMPOSITION TILEVAC VACUUM

WF

WR

WPWWFWT

WPWIWH

WDWWC

WD

VWCVESTVERTVCT

WIDE FLANGEWALL HUNGWROUGHT IRONWATERPROOF (ING)

WATER RESISTANT

WORK POINTWELDED WIRE FABRICWEIGHT

VESTIBULEVINYL WALL COVERING

WATER CLOSET

WOODWINDOW

VERTICAL

TR

ULUNOUR

TTC

TTYPTV

THRESTHK

TLTTB

TRZO

T.O.C.TELTEMP

TREAD

TELEVISION

URINAL

TYPICALTOP

TEMPERED

TOP OF CURBTELEPHONE

TERRAZZO

TACKBOARDTHRESHOLDTHICK (NESS)

TOILET (S)

TEXAS ACCESSIBILITY STANDARDS

SOUND TRANSMISSION COEFFICIENT

TEXTURED COATING ON CONCRETE

STA STATION

SYM

TAT.A.S.T.B.TCOC

SYNS/AD

STG

SUSPSW

STR

STCSTDSTL

SYMMETRICALSYNTHETIC

TOILET ACCESSORY

SUPPLY AIR DIFFUSER

TACK BOARD

STANDARD

SUSPENDEDSTRUCTURE (AL)STORAGE

SWITCH

STEEL

SHT

SQSS

SHWRSPEC

SECT

SHLVSF

SHTHG

SCSCHED

SHEETSHOWER(S)

STAINLESS STEEL

SPECIFICATIONSQUARE

SCHEDULESOLID CORE

SHELVES(ING)SQUARE FEET

SHEATHING

SECTIONVENTILATION, AIR CONDITIONING

CONTRACTOR INSTALL

OWNER INSTALLED

STAB STABILIZE (D)

OR UNDER COUNTER LIGHTING

WALL MOUNTED THERMOSTAT

WALL MOUNTED SMOKE DETECTOR

WALL SWITCH (4-WAY)

WALL SWITCH (3-WAY)

WALL SWITCH DIMMER

WALL MOUNTED TRACK LIGHTING

T

WALL MOUNTED BELL CHIME

WALL MOUNTED BELL BUTTON

SD

S

4S3

S WALL SWITCH

WALL MOUNTED DUPLEX POWER OUTLET

WALL MOUNTED DUPLEX POWER OUTLET (GFI)

HANGING LIGHT ABOVE

CONTINUOUS SHELF LIGHTING

WALL MOUNTED LIGHT FIXTURE

WALL MOUNTED COAX OUTLET

WALL MOUNTED DATA OUTLET

WALL MOUNTED TELEPHONE OUTLET

WALL MOUNTED QUADPLEX POWER OUTLET

WALL MOUNTED DUPLEX POWER OUTLET

D

GFI

FLOOR DATA OUTLET

FLOOR TELEPHONE OUTLET

FLOOR DUPLEX OUTLET

WP

FLOOR DATA /

CEILING FAN ABOVE

WALL MOUNTED "HOLLYWOOD" LIGHTING

WITH WEATHERPROOF COVER

(GROUNDED)

(GROUNDED)

ELECTRICAL OUTLET

(GROUNDED)

WALL MOUNTED DATA / ELECTRICAL OUTLET

B

S

C

WALL MOUNTED EXIT LIGHTEXIT

WALL MOUNTED EMERGENCY LIGHT

RECESS MOUNTED SECURITY CONTROL PANELS.C.P.

RECESS MOUNTED SECURITY KEY PADS.K.P.

RECESS MOUNTED SECURITY ACCESS CARDS.A.C.

WALL MOUNTED CLOCK

GROUND MOUNTED UP LIGHT(S)

ELECTRICAL J BOXJ

WALL MOUNTED SUPPLY DIFFUSER

WALL MOUNTED RETURN DIFFUSER

FINISHED WOOD (PLAN, ELEV, AND SECTION)

WOOD FRAMING - INTERRUPTED (BLOCKING, SHIM, ETC.)

BATT INSULATION (SECTION)

WOOD FRAMING - CONTINUOUS (SECTION)

PLASTER (PLAN AND SECTION)

PLYWOOD (SECTION)

GYPSUM BOARD (SECTION)

CEMENT BOARD (SECTION)

TYPICAL CMU (PLAN AND SECTION)

COMPACTED EARTH FILL (SECTION)

CERAMIC TILE (SECTION)

CAST-IN-PLACE CONCRETE (SECTION)

STEEL (PLAN AND SECTION)

BATT INSULATION (SECTION)

LOOSE EARTH FILL (SECTION)

ROCK FILL (SECTION)

SPECIALTY BRICK (PLAN AND SECTION)

ACOUSTICAL TILE (SECTION)

PLASTIC LAMINATE (SECTION)

SOLID SURFACING (SECTION)

COMMON BRICK (PLAN AND SECTION)

SPECIALTY CMU (PLAN AND SECTION)

TYPICAL STONE ( SECTION)

MARBLE (PLAN AND SECTION)

TERRAZZO (SECTION)

GLAZING (PLAN AND SECTION)

G.002

NTS

GENERALINFORMATION

1MATERIAL CONVENTIONS4M.E.P. FLOOR PLAN DRAWING SYMBOLSABBREVIATIONS 7

SHEET NO. :

CITY DWG. NO. :

SHEET TITLE :

CHECKED BY :DRAWN BY :

G.F.S. No :

SCALE :

DATE :

REVIEWED :

GENERAL SERVICESDEPARTMENT

PROJECT NAME :

SEAL(S) :

CONSULTANT(S) :

NO. DESCRIPTION

ISSUE LOGDATE

City Hall AnnexHurricane Mitigation Program

Hurricane Shutters

900 Bagby StreetHouston, TX 77002

Architectural Brave/Architecture4617 Montrose Blvd, Suite C230Houston, TX 77006Voice: 713.524.5858Fax: 713.524.5868B/A Project #: 12128Contact: Silvana Micolich

Structural Walter P. Moore1301 McKinney Suite 1100Houston, Texas 77010

Voice: 713.630.7300 Contact: Daron Hester

1 Owner Review06.20.20122 Issue for Bid07.26.20123 Issue for Permit01.30.2013

SHEET NO. :

CITY DWG. NO. :

SHEET TITLE :

CHECKED BY :DRAWN BY :

G.F.S. No :

SCALE :

DATE :

REVIEWED :

GENERAL SERVICESDEPARTMENT

PROJECT NAME :

SEAL(S) :

CONSULTANT(S) :

NO. DESCRIPTION

ISSUE LOGDATE

City Hall AnnexHurricane Mitigation Program

Hurricane Shutters

900 Bagby StreetHouston, TX 77002

Architectural Brave/Architecture4617 Montrose Blvd, Suite C230Houston, TX 77006Voice: 713.524.5858Fax: 713.524.5868B/A Project #: 12128Contact: Silvana Micolich

Structural Walter P. Moore1301 McKinney Suite 1100Houston, Texas 77010

Voice: 713.630.7300 Contact: Daron Hester

1 Owner Review06.20.20122 Issue for Bid07.26.20123 Issue for Permit01.30.2013

D.101

AS NOTED

DEMOLITION

ACFV

53/32" = 1'-0"DEMOLITION FIRST FLOOR PLAN 1

NORTH

FLOOR PLAN

SHEET NO. :

CITY DWG. NO. :

SHEET TITLE :

CHECKED BY :DRAWN BY :

G.F.S. No :

SCALE :

DATE :

REVIEWED :

GENERAL SERVICESDEPARTMENT

PROJECT NAME :

SEAL(S) :

CONSULTANT(S) :

NO. DESCRIPTION

ISSUE LOGDATE

City Hall AnnexHurricane Mitigation Program

Hurricane Shutters

900 Bagby StreetHouston, TX 77002

Architectural Brave/Architecture4617 Montrose Blvd, Suite C230Houston, TX 77006Voice: 713.524.5858Fax: 713.524.5868B/A Project #: 12128Contact: Silvana Micolich

Structural Walter P. Moore1301 McKinney Suite 1100Houston, Texas 77010

Voice: 713.630.7300 Contact: Daron Hester

1 Owner Review06.20.20122 Issue for Bid07.26.20123 Issue for Permit01.30.2013

D.102

AS NOTED

DEMOLITION REFLECTED

ACFV

53/32" = 1'-0"DEMOLITION REFLECTED CEILING PLAN

CEILING PLAN

1

NORTH

SHEET NO. :

CITY DWG. NO. :

SHEET TITLE :

CHECKED BY :DRAWN BY :

G.F.S. No :

SCALE :

DATE :

REVIEWED :

GENERAL SERVICESDEPARTMENT

PROJECT NAME :

SEAL(S) :

CONSULTANT(S) :

NO. DESCRIPTION

ISSUE LOGDATE

City Hall AnnexHurricane Mitigation Program

Hurricane Shutters

900 Bagby StreetHouston, TX 77002

Architectural Brave/Architecture4617 Montrose Blvd, Suite C230Houston, TX 77006Voice: 713.524.5858Fax: 713.524.5868B/A Project #: 12128Contact: Silvana Micolich

Structural Walter P. Moore1301 McKinney Suite 1100Houston, Texas 77010

Voice: 713.630.7300 Contact: Daron Hester

1 Owner Review06.20.20122 Issue for Bid07.26.20123 Issue for Permit01.30.2013

A.101

AS NOTED

FLOOR PLAN

ACFV

53/32" = 1'-0"FIRST FLOOR PLAN 1

NORTH

KEY NOTES

SHEET NO. :

CITY DWG. NO. :

SHEET TITLE :

CHECKED BY :DRAWN BY :

G.F.S. No :

SCALE :

DATE :

REVIEWED :

GENERAL SERVICESDEPARTMENT

PROJECT NAME :

SEAL(S) :

CONSULTANT(S) :

NO. DESCRIPTION

ISSUE LOGDATE

City Hall AnnexHurricane Mitigation Program

Hurricane Shutters

900 Bagby StreetHouston, TX 77002

Architectural Brave/Architecture4617 Montrose Blvd, Suite C230Houston, TX 77006Voice: 713.524.5858Fax: 713.524.5868B/A Project #: 12128Contact: Silvana Micolich

Structural Walter P. Moore1301 McKinney Suite 1100Houston, Texas 77010

Voice: 713.630.7300 Contact: Daron Hester

1 Owner Review06.20.20122 Issue for Bid07.26.20123 Issue for Permit01.30.2013

A.102

AS NOTED

CEILING PLAN

ACFV

53/32" = 1'-0"REFLECTED CEILING PLAN 1

NORTH

REFLECTED

SHEET NO. :

CITY DWG. NO. :

SHEET TITLE :

CHECKED BY :DRAWN BY :

G.F.S. No :

SCALE :

DATE :

REVIEWED :

GENERAL SERVICESDEPARTMENT

PROJECT NAME :

SEAL(S) :

CONSULTANT(S) :

NO. DESCRIPTION

ISSUE LOGDATE

City Hall AnnexHurricane Mitigation Program

Hurricane Shutters

900 Bagby StreetHouston, TX 77002

Architectural Brave/Architecture4617 Montrose Blvd, Suite C230Houston, TX 77006Voice: 713.524.5858Fax: 713.524.5868B/A Project #: 12128Contact: Silvana Micolich

Structural Walter P. Moore1301 McKinney Suite 1100Houston, Texas 77010

Voice: 713.630.7300 Contact: Daron Hester

1 Owner Review06.20.20122 Issue for Bid07.26.20123 Issue for Permit01.30.2013

A.701

AS NOTEDACFV

53/8" = 1'-0"ELEVATION 1

ELEVATIONS

63/8" = 1'-0"ELEVATION 103/8" = 1'-0" SECTION

SECTIONS & DETAILS

7PLAN DETAIL AT FLOOR - TYP. ALL COLUMNS 111 1/2" = 1'-0" PLAN DETAIL 1 1/2" = 1'-0"PLAN DETAIL151 1/2" = 1'-0"

SECTION DETAIL - EXPANSION JOINT 143" = 1'-0"