Page 1: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA

DOCUMENTACIÓNTÉCNICA

www.bemask-pro.com

Page 2: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA

6060º

NOMBRE COMERCIAL BEMask-Pro

HOMOLOGADA SEGÚN NORMATIVA EUROPEA CWA 17553:2020(E)

AMSLAB Report No: 20-008544

Tecnología SILVERPLUS con iones de plata

DESCRIPCIÓN DE PRODUCTOMascarilla higiénica reutilizableCubre boca, nariz y barbillaSujección elástica ajustable detrás de las orejasReutilizableLavadosTemperatura recomendada de lavadoPlanchado recomendado del revés temperatura media

HidrófobaAntifúngicaTejido de Poliester 100%Confortable AntialérgicaNo tóxicaReciclablePackagingFabricación en EspañaTallas: Small · Medium · Large · X-Large

RUCO-BAC AGP Determination of antiviral activity acc. to ISO 18184:2019 (1) J001665-1/J001665-2.

Page 3: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 4: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 5: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 6: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 7: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 8: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 9: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 10: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 11: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 12: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 13: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 14: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 15: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 16: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 17: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 18: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 19: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 20: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 21: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 22: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 23: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 24: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 25: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 26: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 27: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 28: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 29: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 30: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 31: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 32: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA

Test identification Reference: J001665-1 ISO 18184:2019

Page 1 of 7

ISO 18184:2019 Textiles- Determination of antiviral activity of textile products

Microbiological Solutions Limited (MSL) Gollinrod, Walmersley, Bury, BL9 5NB, UK

Angela Davies, CEO

Customer: RUDOLF GMBH Contact name: Stephen Muller Email: [email protected] Address: Altvaterstrasse 58-64 Geretsried, 82538, Germany PO/Quote number: Q002627 Report Date: 23/06/2020 Issue Number: 1

____________________ ____________________ Megan Barrett Peter Thistlethwaite

Laboratory Manager Technical Projects Manager

Page 33: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA

Test identification Reference: J001665-1 ISO 18184:2019

Page 2 of 7

Test Result Summary

The test results on this report refer only to the items tested as supplied by the customer. This report shall not be reproduced except in full and with written approval of Microbiological Solutions Ltd. All reports are archived for a minimum of 2 years.

The sample will be retained for 1 month unless otherwise requested in writing.

The members of the family Coronaviridae are enveloped and have a positive sense RNA genome. Coronaviruses have a distinct morphology with an outer ‘corona’ of embedded envelope spikes. These viruses cause a broad spectrum of animal and human disease.

Andrew M.Q. King, Michael J. Adams, Eric B. Carstens, and Elliot J. Lefkowitz Virus Taxonomy, Classification and Nomenclature of Viruses, Ninth Report of the International Committee on Taxonomy of Viruses 2012 ISBN 9780123846846

Test information Deviation Name of Product Control: UA – Untreated control

Test 1 : 1 A – RUCO-BAC AGP Test 2 : 1 A-5W – RUCO-BAC after 5 washes 40°c

Batch Number & Expiry Date N/S

Date of Delivery 29/04/2020

Period of Analysis 11/06/2020-18/06/2020

Manufacturer / Supplier RUDOLF GMBH

Storage Conditions Ambient

Appearance of the Product White fabric

Neutralisation Method Dilution Product Diluent N/A Test Concentrations Neat as supplied Test Temperature 250C + 1°C Temperature of Incubation 37oC ±1oC Identification of the Viral Strains: Feline corona virus, Strain Munich Contact Times 1 hour + 10s

Feline coronavirus COVID-19 (SARS—CoV2)

Realm Riboviria Riboviria

Order Nidovirales Nidovirales

Family Coronaviridae Coronaviridae

Genus Alphacoronavirus Betacoronavirus

Species Alphacoronavirus 1 COVID-19

See results summary below for log reductions

Page 34: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA

Test identification Reference: J001665-1 ISO 18184:2019

Page 3 of 7

Scope This standard outlines the test method for the determination of the antiviral activity of the textile products against specified viruses. Method A 20mmx20mm sample of test material is cut (overall mass should be 0.40g and can be made up with extra material if required). 9 control pieces are required and 6 test pieces. 3 pieces of each material are used to test the effect of the fabric on cells without virus (cytotoxicity), 3 control pieces are used to recover the starting titre of virus. The remaining pieces ate inoculated with 200μl of virus at a concentration of ~107 TCID50 (giving a final concentration of 105) and left for the contact time. Following the contact time, the fabric is recovered in 20ml of cell culture media and enumerated onto an appropriate cell line. TCID50 is calculated following the appropriate incubation time. Antiviral activity is calculated by comparison of the antiviral test material to the immediate recover from the control fabric.

Page 35: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 36: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 37: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 38: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA

Test identification Reference: J001665-1 ISO 18184:2019

Page 7 of 7

Controls

Initial inoculum 7.92 Valid

Cytotoxicity Test 1 4.17 Valid

Cytotoxicity Test 2 4.25 Valid

Cytotoxicity Control 4.33 Valid

Controls

Page 39: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA

Test identification Reference: J001665-2 ISO 18184:2019

Page 1 of 7

ISO 18184:2019 Textiles- Determination of antiviral activity of textile products

Microbiological Solutions Limited (MSL) Gollinrod, Walmersley, Bury, BL9 5NB, UK

Angela Davies, CEO

Customer: RUDOLF GMBH Contact name: Stephen Muller Email: [email protected] Address: Altvaterstrasse 58-64 Geretsried, 82538, Germany PO/Quote number: Q002627 Report Date: 23/06/2020 Issue Number: 1

____________________ ____________________ Megan Barrett Peter Thistlethwaite

Laboratory Manager Technical Projects Manager

Page 40: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA

Test identification Reference: J001665-2 ISO 18184:2019

Page 2 of 7

Test Result Summary

The test results on this report refer only to the items tested as supplied by the customer. This report shall not be reproduced except in full and with written approval of Microbiological Solutions Ltd. All reports are archived for a minimum of 2 years.

The sample will be retained for 1 month unless otherwise requested in writing.

The members of the family Coronaviridae are enveloped and have a positive sense RNA genome. Coronaviruses have a distinct morphology with an outer ‘corona’ of embedded envelope spikes. These viruses cause a broad spectrum of animal and human disease.

Andrew M.Q. King, Michael J. Adams, Eric B. Carstens, and Elliot J. Lefkowitz Virus Taxonomy, Classification and Nomenclature of Viruses, Ninth Report of the International Committee on Taxonomy of Viruses 2012 ISBN 9780123846846

Test information Deviation Name of Product Control: UB – Untreated control

Test 1: 1 B – RUCO-BAC AGP Test 2: 1 B-5W – RUCO-BAC after 5 washes 40°c

Batch Number & Expiry Date N/S

Date of Delivery 29/04/2020

Period of Analysis 11/06/2020-18/06/2020

Manufacturer / Supplier RUDOLF GMBH

Storage Conditions Ambient

Appearance of the Product White fabric

Neutralisation Method Dilution Product Diluent N/A Test Concentrations Neat as supplied Test Temperature 250C + 1°C Temperature of Incubation 37oC ±1oC Identification of the Viral Strains: Feline corona virus, Strain Munich Contact Times 1 hour + 10s

Feline coronavirus COVID-19 (SARS—CoV2)

Realm Riboviria Riboviria

Order Nidovirales Nidovirales

Family Coronaviridae Coronaviridae

Genus Alphacoronavirus Betacoronavirus

Species Alphacoronavirus 1 COVID-19

See results summary below for log reductions.

Page 41: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA

Test identification Reference: J001665-2 ISO 18184:2019

Page 3 of 7

Scope This standard outlines the test method for the determination of the antiviral activity of the textile products against specified viruses. Method A 20mmx20mm sample of test material is cut (overall mass should be 0.40g and can be made up with extra material if required). 9 control pieces are required and 6 test pieces. 3 pieces of each material are used to test the effect of the fabric on cells without virus (cytotoxicity), 3 control pieces are used to recover the starting titre of virus. The remaining pieces ate inoculated with 200μl of virus at a concentration of ~107 TCID50 (giving a final concentration of 105) and left for the contact time. Following the contact time, the fabric is recovered in 20ml of cell culture media and enumerated onto an appropriate cell line. TCID50 is calculated following the appropriate incubation time. Antiviral activity is calculated by comparison of the antiviral test material to the immediate recover from the control fabric.

Page 42: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 43: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 44: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 45: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA

Test identification Reference: J001665-2 ISO 18184:2019

Page 7 of 7

Controls

Initial inoculum 7.92 Valid

Cytotoxicity Test 1 4.13 Valid

Cytotoxicity Test 2 4.08 Valid

Cytotoxicity Control 4.29 Valid

Controls

Page 46: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA

07/09/2020Job No./Report No: 20-008544Date:

TEST REPORT

Ibercotton, S.A.Client:

Attn:Cesar Laborda

Tel:0034 976773896 Fax:

Address:Av/Diagonal,15-6-7 ZARAGOZA ZARAGOZA ESPAÑA

[email protected]:

CL-1387Code:

The following sample was (were) submitted and identified by the client as:

UnknownComposition indicated:

MASCARILLA NEGRAReference No.:

Batch No.:

Serie :

MASK

Job no Report No.:

Test Start Date:

Test End Date:

19/08/2020

19/08/2020

20-008544

07/09/2020

Receiving Date:

Sample description:

SOP description ConclusionsSOP305 - Change of appearance after washing (Garments and fabrics) See Results

SOP 342- Bacterial Filtration Efficiency (BFE)

SOP 342- Bacterial Filtration Efficiency (BFE) - After Washing

SOP106 - Determination of breathability (Differential Pressure) - Original See Results

SOP106 - Determination of breathability (Differential Pressure) - After Washing See Results

Sample Tested

SUMMARY OF TEST CONCLUSIONS

Pag. 1 of

-The laboratory is not responsible for the information received by the client (grey shaded fields)-Reported results do not include uncertainties (but are available for the customer).-Opinions and interpretations expressed herein are outside the scope of accreditation.-Unless otherwise stated the result shown in this test report refer only the sample/s tested and such sample/s are retained for 30 days only.-Test reports without AMSLab seal and authorized signatures are invalid.-This document can’t be reproduced or modified except in full, without prior given approval of the company.-Any printed copy of this document is copy from the original digital document.Applied Mass Spectrometry Laboratory, S.L.U.Avda. Benigno Rivera, n°56 27003 Lugo (Spain)Tel.: +34 982808074 - Fax.: +34 982803180 [email protected] / www.ams-lab.com 5

See Results

See Results

Page 47: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA

07/09/2020Job No./Report No: 20-008544Date:

TEST REPORT

SOP305 - Change of appearance after washing (Garments and fabrics)

4ID

S-200819-00005ID AMSLab

MASK BLACK (60 WASHING CYCLES AT 60ºC)Description

See ResultsConclusion

CAS S-200819-00005

Change of appearance after washing Slight change

Number of cycles 60

Washing Temperature 60ºC

Notes:Note 1: Washing and drying process applied based on UNE-EN ISO 6330:2012

Note 2:- Detergent: 20 gr of Commercial detergent / - Drying procedure: Air dry without tumble dry.- n.a.: not applicable- Requirement: No obvious change/colour/shape/appearance/seams/embroidery/trimmings/applications

Note 3 - Meaning of the grades of change of appearance:- No change in appearance after washing and drying process- Slight change in appearance after washing and drying process- Moderate change in appearance after washing and drying process- Severe change in appearance after washing and drying process

SOP 342- Bacterial Filtration Efficiency (BFE)

2ID

S-200819-00003ID AMSLab

MASK BLACK (ORIGINAL)Description

See ResultsConclusion

CAS S-200819-00003

Test 1: Bacterial Filtration Efficiency 86.7

Test 1: Number of Bacteria 345

Test 2: Bacterial Filtration Efficiency 86.1

Test 2: Number of Bacteria 362

Test 3: Bacterial Filtration Efficiency 85.5

Test 3: Number of Bacteria 378

Test 4: Bacterial Filtration Efficiency 85.2

Test 4: Number of Bacteria 386

Test 5: Bacterial Filtration Efficiency 85.0

Test 5: Number of Bacteria 391

Notes:Test Method: EN 14683:2019+AC:2019 (TS EN 14683+AC:2019) Annex-B / Medical Face Masks - Requirements and Test Methods

Requirements by specifications:Spanish specification UNE 0065:2020: >=90%European specification CWA 17553:2020: Level >=90% and

Pag. 2 of

-The laboratory is not responsible for the information received by the client (grey shaded fields)-Reported results do not include uncertainties (but are available for the customer).-Opinions and interpretations expressed herein are outside the scope of accreditation.-Unless otherwise stated the result shown in this test report refer only the sample/s tested and such sample/s are retained for 30 days only.-Test reports without AMSLab seal and authorized signatures are invalid.-This document can’t be reproduced or modified except in full, without prior given approval of the company.-Any printed copy of this document is copy from the original digital document.Applied Mass Spectrometry Laboratory, S.L.U.Avda. Benigno Rivera, n°56 27003 Lugo (Spain)Tel.: +34 982808074 - Fax.: +34 982803180 [email protected] / www.ams-lab.com 5

Page 48: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA

07/09/2020Job No./Report No: 20-008544Date:

TEST REPORT

European specification CWA 17553:2020: Level >=70%

Other requirements:- Surgical Mask type I by UNE-EN 14683: >=95%- Surgical Mask type II by UNE-EN 14683: >=98%- Surgical Mask type IIR by UNE-EN 14683: >=98%

Report unit Bacterial Filtration Efficiency = %Report unit Number of Bacteria = cfu/mL

A specimen of the mask material is clamped between a impactor and an aerosol chamber. An aerosol of Staphylococcus aureus is introducedinto the aerosol chamber and drawn through the mask material and the impactor under vacuum. The bacterial filtration efficiency of the mask isgiven by the number of colony forming units passing through the medical face mask material expressed as a percentage of the number ofcolony forming units present in the challenge aerosol.

Test Flow Rate: 28,3 L/minTest Flow Time: 2 minuteSample Sizes: 10x10 cm2Microorganism: Staphylococcus aureus ATCC 6538Bacterial concentration (cfu/ml): 5x10E5 cfu/mlIncubation conditions: 24 hour, 35C ± 2CPositive control sample average of number of Bacteria (C): 2.6x10E3 cfu/ml

(*) Test subcontracted and accredited for medical mask tests (EN 14683). Results in subcontracted report number: 20030808

SOP 342- Bacterial Filtration Efficiency (BFE) - After Washing

5ID

S-200819-00006ID AMSLab

MASK BLACK (AFTER 60 WASHING CYCLES AT 60ºC)Description

See ResultsConclusion

CAS S-200819-00006

Test 1: Bacterial Filtration Efficiency 87.0

Test 1: Number of Bacteria 337

Test 2: Bacterial Filtration Efficiency 87.3

Test 2: Number of Bacteria 330

Test 3: Bacterial Filtration Efficiency 87.0

Test 3: Number of Bacteria 339

Test 4: Bacterial Filtration Efficiency 86.9

Test 4: Number of Bacteria 341

Test 5: Bacterial Filtration Efficiency 86.7

Test 5: Number of Bacteria 345

Notes:Test Method: EN 14683:2019+AC:2019 (TS EN 14683+AC:2019) Annex-B / Medical Face Masks - Requirements and Test Methods

Requirements by specifications:Spanish specification UNE 0065:2020: >=90%European specification CWA 17553:2020: Level >=90% andEuropean specification CWA 17553:2020: Level >=70%

Other requirements:- Surgical Mask type I by UNE-EN 14683: >=95%- Surgical Mask type II by UNE-EN 14683: >=98%- Surgical Mask type IIR by UNE-EN 14683: >=98%

Pag. 3 of

-The laboratory is not responsible for the information received by the client (grey shaded fields)-Reported results do not include uncertainties (but are available for the customer).-Opinions and interpretations expressed herein are outside the scope of accreditation.-Unless otherwise stated the result shown in this test report refer only the sample/s tested and such sample/s are retained for 30 days only.-Test reports without AMSLab seal and authorized signatures are invalid.-This document can’t be reproduced or modified except in full, without prior given approval of the company.-Any printed copy of this document is copy from the original digital document.Applied Mass Spectrometry Laboratory, S.L.U.Avda. Benigno Rivera, n°56 27003 Lugo (Spain)Tel.: +34 982808074 - Fax.: +34 982803180 [email protected] / www.ams-lab.com 5

Page 49: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA

07/09/2020Job No./Report No: 20-008544Date:

TEST REPORT

Report unit Bacterial Filtration Efficiency = %Report unit Number of Bacteria = cfu/mL

A specimen of the mask material is clamped between a impactor and an aerosol chamber. An aerosol of Staphylococcus aureus is introducedinto the aerosol chamber and drawn through the mask material and the impactor under vacuum. The bacterial filtration efficiency of the mask isgiven by the number of colony forming units passing through the medical face mask material expressed as a percentage of the number ofcolony forming units present in the challenge aerosol.

Test Flow Rate: 28,3 L/minTest Flow Time: 2 minuteSample Sizes: 10x10 cm2Microorganism: Staphylococcus aureus ATCC 6538Bacterial concentration (cfu/ml): 5x10E5 cfu/mlIncubation conditions: 24 hour, 35C ± 2CPositive control sample average of number of Bacteria (C): 2.6x10E3 cfu/ml

(*) Test subcontracted and accredited for medical mask tests (EN 14683). Results in subcontracted report number: 20030809

SOP106 - Determination of breathability (Differential Pressure) - Original

1ID

S-200819-00002ID AMSLab

MASK BLACK (ORIGINAL)Description

See ResultsConclusion

CAS S-200819-00002

Average Differential pressure (Pa/cm2) 39

Value 1 Differential pressure (Pa/cm2) 40

Value 2 Differential pressure (Pa/cm2) 41

Value 3 Differential pressure (Pa/cm2) 39

Value 4 Differential pressure (Pa/cm2) 35

Value 5 Differential pressure (Pa/cm2) 34

Notes:Note 1: Applied standard UNE-EN 14683:2019 and Spanish Specification UNE 0064-1, 0064-2, 0065 and European Specification CWA 17553Note 2: Size of test specimen: 4.9 cm2Note 3: Tested area of the test specimen: 2.5 cmNote 4: Flow of air: (8 ± 0.2) l/minNote 5: Velocity of 272 l/m2/s or 272 mm/sNote 6: Report Unit: Pa and P (Pa/cm2)Note 7: Number of samples tested: 5 / Number of measurements: 5Note 8: Conditioned samples: 4 hours at 21 ± 5 ºC and 85 ± 5 HRNote 9: n.a. = not applicable

Requirements by specifications:- Non-reusable Hygienic Mask by UNE 0064-1-2: < 60 Pa/cm2- Reusable Hygienic Mask by UNE 0065: < 60 Pa/cm2- European specification CWA 17553:2020: <=70 Pa/cm2

Other requirements:- Surgical Mask type I by UNE-EN 14683: < 40 Pa/cm2- Surgical Mask type II by UNE-EN 14683: < 40 Pa/cm2- Surgical Mask type IIR by UNE-EN 14683: < 60 Pa/cm2

Specific Notes:(**) The result is out of specifications

Pag. 4 of

-The laboratory is not responsible for the information received by the client (grey shaded fields)-Reported results do not include uncertainties (but are available for the customer).-Opinions and interpretations expressed herein are outside the scope of accreditation.-Unless otherwise stated the result shown in this test report refer only the sample/s tested and such sample/s are retained for 30 days only.-Test reports without AMSLab seal and authorized signatures are invalid.-This document can’t be reproduced or modified except in full, without prior given approval of the company.-Any printed copy of this document is copy from the original digital document.Applied Mass Spectrometry Laboratory, S.L.U.Avda. Benigno Rivera, n°56 27003 Lugo (Spain)Tel.: +34 982808074 - Fax.: +34 982803180 [email protected] / www.ams-lab.com 5

Page 50: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA

07/09/2020Job No./Report No: 20-008544Date:

TEST REPORT

SOP106 - Determination of breathability (Differential Pressure) - After Washing

3ID

S-200819-00004ID AMSLab

MASK BLACK (AFTER 60 WASHING CYCLES AT 60ºC)Description

See ResultsConclusion

CAS S-200819-00004

Average Differential pressure (Pa/cm2) 50

Value 1 Differential pressure (Pa/cm2) 49

Value 2 Differential pressure (Pa/cm2) 51

Value 3 Differential pressure (Pa/cm2) 49

Value 4 Differential pressure (Pa/cm2) 51

Value 5 Differential pressure (Pa/cm2) 50

Notes:Note 1: Applied standard UNE-EN 14683:2019 and Spanish Specification UNE 0064-1, 0064-2, 0065 and European Specification CWA 17553Note 2: Size of test specimen: 4.9 cm2Note 3: Tested area of the test specimen: 2.5 cmNote 4: Flow of air: (8 ± 0.2) l/minNote 5: Velocity of 272 l/m2/s or 272 mm/sNote 6: Report Unit: Pa and P (Pa/cm2)Note 7: Number of samples tested: 5 / Number of measurements: 5Note 8: Conditioned samples: 4 hours at 21 ± 5 ºC and 85 ± 5 HRNote 9: n.a. = not applicable

Requirements by specifications:- Non-reusable Hygienic Mask by UNE 0064-1-2: < 60 Pa/cm2- Reusable Hygienic Mask by UNE 0065: < 60 Pa/cm2- European specification CWA 17553:2020: <=70 Pa/cm2

Other requirements:- Surgical Mask type I by UNE-EN 14683: < 40 Pa/cm2- Surgical Mask type II by UNE-EN 14683: < 40 Pa/cm2- Surgical Mask type IIR by UNE-EN 14683: < 60 Pa/cm2

Specific Notes:(**) The result is out of specifications

07/09/2020Issue Date:

Signed: Manuel Lolo Signed: Pablo Perez Signed: Esteban Ramirez

General Manager Physical Lab ManagerChemical Lab Manager

Pag. 5 of

-The laboratory is not responsible for the information received by the client (grey shaded fields)-Reported results do not include uncertainties (but are available for the customer).-Opinions and interpretations expressed herein are outside the scope of accreditation.-Unless otherwise stated the result shown in this test report refer only the sample/s tested and such sample/s are retained for 30 days only.-Test reports without AMSLab seal and authorized signatures are invalid.-This document can’t be reproduced or modified except in full, without prior given approval of the company.-Any printed copy of this document is copy from the original digital document.Applied Mass Spectrometry Laboratory, S.L.U.Avda. Benigno Rivera, n°56 27003 Lugo (Spain)Tel.: +34 982808074 - Fax.: +34 982803180 [email protected] / www.ams-lab.com 5

Page 51: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA

AITEX

INSTITUTO TECNOLÓGICO TEf,TIL

PLAZA EMILIO SALA, 1

03801 ALC0Y (ALICANTE) ESPAÑA, SPAIN

Leferon, S.L.Mas Roger. Juan de la Cierva 14-1608397 Pineda del Mar (Barcelona), SPAIN

está autorizada, según el STANDARD 100 by 0EK0-TEX@ y nuestro informe

de ensayo n'.20200K0934, a usar la marca STANDARD 100 by

OEKO-TEX@

Silvia Devesa ValenciaSubdirectora lnnovación

OEKO-TEX@INSPIRING CONFIDENCE

La empresa

OEKO.TEX@CONFIDENCE IN TEXTILES

ffiSTANDARD 1OO

20044N1251 A|TEX,

Control de sustancias noc¡vas

www.oeko-tex.com/standard1 00

para los siguientes artículos:

Hilados de poliamida tintados con colorantes ácidos y premetalizados e hilados de poliéster tintados con colorantesdispersos.

Los resultados de la inspección realizada según el STANDARD 100 by 0EK0-TEX@, Apéndice 4, clase de productos l, muestranque los aftículos mencionados anteriormente cumplen los requisitos ecológico-humanos del STANDARD 100 by 0EK0-TEX@

actualmente establecidos en el Apéndice 4 para artículos de bebé.

Los artículos certificados cumplen con requisitos del anexo XVll del REACH (incluyendo el uso de colorantes azo, níquel, etc...),asícomo con los requisitos americanos en cuanto al contenido total de plomo en artículos de niños (CPSIA; con excepción de

accesorios hechos de cristal) y del estándar chino GB 18401 :2010 (requisito de etiquetado no verificado).

El titular de este certificado se compromete con el instituto, mediante una declaración de conformidad según la norma

15017050-1, a colocar la etiqueta STANDARD 100 by 0EK0-TEX@ únicamente en los ar1ículos que se correspondan con las

muestras ensayadas. La conformidad se comprueba mediante auditorías.

El certificado 2004AN1251 es válido hasta el 30.04.2021

Alcoy, 12.06.2020

lsabel Soriano SarrióJefa Area lnnovación

0EK0-TEX@ Association I Genferstrasse 23 I CH-8002 Zurich ffi

Page 52: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA

AITEX

INSTITUTO TECNOLÓGICO TEXTIL

PLAZA EMILIO SALA, 1

03801 ALCOY (ALTCANTE) ESPAÑA, SpAtN

Leferon, S.L.Mas Roger. Juan de la Gierva 14-1608397 Pineda del Mar (Barcelona), SPAIN

is granted authorisation according to STANDARD 100 by 0EK0-TEX@ to use

the STANDARD 100 by 0EK0-TEX@ mark, based 0n ourtest report

20200K0934

OEKO.TEX@INSPIRING CONFIDENCE

The company

OEKO.TEX@CONFIDENCE IN TEXTILES

#,ftä¿8"STANDARD 1OO

20044N1251 A|TEX,

Tested lor harmful substances

wwfioeko-tex.com/standardl 00E]fiÉEr

ffifor the following articles:

Yarns made of polyamide dyed with acids and premetallised dyestutfs and yarns made of polyester dyed with dispersedyestuffs.

The results of the inspection made according to STANDARD 1 00 by 0EK0 -TEX@, Appendix 4, product class I have shown thatthe above mentioned goods meet the human-ecological requirements of the STANDARD 1 00 by 0EK0 -TEX@ presently

established in Appendix 4 for baby articles.

The cedified adicles fulfil requirements of Annex XVll of REACH (incl. the use of azo colourants, nickel release, etc.), the American

requirement regarding total content of lead in children's articles (CPSIA; with the exception of accessories made from glass) and

of the Chinese standard GB 18401 :2010 (labelling requirements were not verified).

The holder of the certificate, who has issued a conformity declaration according to lS0 17050-1 , is under an obligation to use the

STANDARD 100 by 0EK0-TEX@ mark only in conjunction with products that conform with the sample initially tested. The

conformity is verified by audits.

The certificate 20044N1251 is valid unt¡l 30.04.2021

Alcoy, 12.06.2020

ffiSilvia Devesa Valencialnnovalion Assistanl Manager

lsabel Soriano SarrióChief of lnnovation Area

0EK0-TEX@ Association I Genferstrasse 23 I CH-8002 Zurich ffi

Page 53: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 54: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 55: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 56: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA
Page 57: DOCUMENTACIÓN TÉCNICA€¦ · Code:CL-1387 The following sample was (were) submitted and identified by the client as: Composition indicated: Unknown Reference No.: MASCARILLA NEGRA

LEFERON SL Zona Ind. Mas Roger – Juan de la Cierva 35 – Apdo. 144 – 08397 Pineda de Mar – Barcelona – España –

Tel. 0034 937670847 Fax 0034 937670989 - [email protected]

Test Report AWE-16-0457 03.03.16 FR/NI

Material: SoftAir 78/72 silver colored and treated silver.

Subject: test of the antibacterial effects acc. to AATCC 100 Test and Results: In initial state and after several washes at 40ºC

Antibacterial Activity – Test institute: Biotech Testing Services, Mumbai, India Test method: AATCC 100-2012, Assessment of antibacterial finishes on textiles Bacteria contact: 37 °C, 20 h

Reducton of Bacteria % Staphylococcus aureus (ATCC 6538)

fabric style Original 20 washes 35 washes 75 washes *)BTS

SoftAir 78/72 Silver

9191 99,15

9213 93,52

9221 87,78

9241 62,50

* N° for external tests / Note: Presentation of data should not be construed as a public healthclaim.