Daikin VRV Catalog 131014

download Daikin VRV Catalog 131014

of 84

Transcript of Daikin VRV Catalog 131014

  • 7/24/2019 Daikin VRV Catalog 131014

    1/84

    NEXT GENERATION VRVFROM THE WORLD LEADER IN AIRCONDITIONING

    Heat Pump - 50 Hz

    DAIPL-12H

  • 7/24/2019 Daikin VRV Catalog 131014

    2/84

    CONTROLSYSTEMS

    SPECIFICATIONS

    MAINFEATURES

    p52

    p34

    p06

    AIR TREATMENTEQUIPMENTLINEUP

    OUTDOOR UNITCOMBINATIONS

    OUTDOOR UNITLINEUP

    p66

    p47

    p16

    OPTION LIST

    INDOOR UNITLINEUP

    p48

    p17INDE

    X

  • 7/24/2019 Daikin VRV Catalog 131014

    3/84

    WORLDS MOST ADVANCEDVRV IVAIRCONDITIONING SYSTEM WITH

    INNOVATIVE VRT TECHNOLOGY.

    FIRST LAUNCHED IN JAPAN IN 1982, THE DAIKIN VRV SYSTEM HAS BEEN EMBRACED BY THE

    WORLD MARKETS FOR OVER THREE DECADES. NOW, WE AT DAIKIN INTRODUCE THE NEXT

    GENERATION VRV IV SYSTEM TO REINFORCE OUR INDUSTRY LEADERSHIP. THE SYSTEM NOW

    OFFERS AN ENHANCED LINE-UP TO MEET AN EVER WIDENING VARIETY OF NEEDS, WHILEIMPROVING ENERGY SAVINGS, COMFORT AND EASE OF INSTALLATION.

    THE VRV IV IS THE MOST ADVANCED AIRCONDITIONING SYSTEM IN THE WORLD AND IS

    IDEAL FOR LARGE AND SMALL SPACES.

    ENHANCED

    LINEUP

    Up to 60 HP

    ENERGYSAVING

    Higher COP and

    VRT technology

    EASE OF

    INSTALLATION

    Compact and

    Lightweight design

    COMFORT

    Lower operation

    sound

    ENERGY SAVING TECHNOLOGY FOR VRV SYSTEM

    The new VRV IVsystem now features VRTtechnology. VRTautomatically adjusts refrigerant temperature to individual building

    and climate requirement, thus further improving annual energy

    efficiency and maintaining comfort. With this technology, running

    costs are reduced.

    VRT-VARIABLE REFRIGERANT TEMPERATURE

  • 7/24/2019 Daikin VRV Catalog 131014

    4/84

    DAIKINTHE WORLD LEADER IN AIRCONDITIONING

    EUROPE/MIDDLE EAST/AFRICA CHINA

    Daikin AirconditioningCentral Europe

    Daikin(China) Investment

    Daikin AirconditioningShanghai

    Xian Daikin QinganCompressor

    DaikinEurope N.V.

    Hui Zhou Daikin SunsAirconditioning

    Daikin Device(Suzhou)

    Daikin Fluoro CoatingShanghai

    Daikin AirconditioningUK

    Daikin FluorochemicalsChina

    Daikin AirconditioningSpain

    Daikin AirconditioningFrance

    Daikin IndustriesCzech Republic

    Daikin AirconditioningItaly

    Daikin AirconditioningGermany

    Daikin ChemicalFrance

    AT DAIKIN WE ARE A LEADING INNOVATORAND PROVIDER OF ADVANCED, HIGH-QUALITY

    AIRCONDITIONING SOLUTIONS FOR RESIDENTIAL,

    COMMERCIAL AND INDUSTRIAL APPLICATIONS.

    As World's No. 1 Airconditioning Company, we are

    committed to delivering airconditioning solutions that

    enhance the quality of life all around the world. We,

    at Daikin Industries Ltd., are a diverse multinational

    company, active in airconditioning, chemicals and oil

    hydraulics, was established in 1924. With headquarters

    at Osaka, Japan, our Daikin family has more than

    51,000 members, working across 60 production base

    units and 208 consolidated subsidiaries worldwide. As

    the world's sole manufacturer that develops a long line

    of products from refrigerants to airconditioners, we

    advocate comfortable living on the strength of advanced

    technologies.

    We are present in USA, Europe and Russia, the Middle

    East, Africa, Asia, Oceania and Middle-South America.

    We aim to serve our customers in each of these markets byproviding optimal airconditioning products.2

  • 7/24/2019 Daikin VRV Catalog 131014

    5/84

    Osaka

    Tokyo

    ProductionSite

    Overseas

    ASIA/OCEANIA

    NORTH AMERICA/

    CENTRAL & SOUTH AMERICA

    Daikin IndustriesThailand

    Daikin CompressorIndustries

    Daikin America Daikin AC(Americas)

    Daikin AirconditioningSingapore

    Daikin Australia Daikin HoldingUSA

    Daikin AirconditioningIndia

    (Inside Umeda Center Building) Japan

    3

  • 7/24/2019 Daikin VRV Catalog 131014

    6/84

    EXPLORING NEW R&D FRONTIERS

    AT DAIKIN, WE ARE CREATING VALUETHROUGH INNOVATIVE TECHNOLOGIES.

    AS A GLOBAL INDUSTRY FRONTRUNNER,

    WE ARE CARRYING OUT RESEARCH

    AND DEVELOPMENT ON THE WORLDS

    MOST ADVANCED AIRCONDITIONING

    TECHNOLOGY.

    Our strong R&D edge has helped us create

    futuristic products that enrich peoples lives. As

    symbolised by the VRV, Daikin has put forth a

    multitude of products and varied technology

    that have always been, and continue to be, at

    the forefront of innovation.

    To be able to offer such products and services

    that delight and astound our customers, we

    have constructed an advanced R&D architecture.

    FORMATION OF A THREE-DIVISION SYSTEM

    OF RESEARCH, IT, AND DEVELOPMENT TO

    SUPPORT OUR SUPERIOR PRODUCTS.

    To create more advanced functions and new

    value, we have instituted specialised R&D

    divisions: the Environmental Technology

    Research Laboratory and the Solution Product

    Development Centre. In combination with the

    Product Development Group, each of the three

    divisions work in close cooperation to precisely

    ascertain the customers needs and to enable

    commercialisation of products, incorporating

    advanced technology that take the lead overour competitors.

    4

  • 7/24/2019 Daikin VRV Catalog 131014

    7/84

    THE SOLUTIONS PRODUCT DEVELOPMENT

    CENTRE: INTEGRATING AIRCONDITIONERS

    WITH IT

    Keeping in mind the changes in business brought

    in by the computerisation and networking

    of society, we have integrated IT into our

    airconditioners, including communication

    technology, software technology and digital

    control. We are initiating R&D that will offer new

    system services - a comfortable environment

    with superior energy savings by networking air

    conditioners. Such a scenario will enable them toexchange information with service centres.

    ENVIRONMENTAL TECHNOLOGY RESEARCH

    LABORATORY: INTENSIVE RESEARCH ON

    ENVIRONMENTALLY CONSCIOUS, ENERGY

    SAVING AIRCONDITIONING TECHNOLOGY

    Accelerating globalisation of our airconditioning

    business and varied needs of customers

    across geographies are increasing our

    research challenges. We have established a

    research laboratory devoted to the two fields

    of airconditioning and the environment.

    With our mission to promote energy savings

    in airconditioners, we are engaged in R&D on

    cutting-edge technologies. Our aim is to create

    futuristic products from fundamental research

    on motor inverters, and other areas to support

    individual product development.

    Going forward, we will elevate our technology

    edge to achieve further business expansionglobally.

    5

  • 7/24/2019 Daikin VRV Catalog 131014

    8/84

    EXCELLENT OPERATIONAL

    PERFORMANCE

    New series with compact and lightweight design

    6 HP-60 HP with 28 models lineup

    320 kg

    0.95 m2

    Compact

    Design

    Normal (Space Saving) Type

    20 HP Product WeightInstallation Space

    Lineup

    HP

    Normal Type

    ENHANCED LINEUP UP TO 60 HP

    6

  • 7/24/2019 Daikin VRV Catalog 131014

    9/84

    Higher Coefficient of Performance (COP)

    *Cooling operation conditions: Indoor temp. of

    27CDB, 19CWB, and outdoor temp. of 35CDB.

    0

    3

    3.5

    4

    4.5

    6 HP

    8 HP

    4.304.41CoolingOperationCOP

    Compact & lightweight design

    Highly-integrated VRV IVsystem offers compactoutdoor units to achievemaximum utilisation of the

    installation space.

    InstallationSpace

    0.71 m2

    Product

    Weight195 kg

    12 HP

    12 HP

    765mm930 mm

    Improves heat exchangerefficency, helps reducedoperation sound.

    Lower operation sound

    Peak in outdoor temperaturePeak in outdoor temperaturePeak in outdoor temperature

    Enable night modeEnable night modeEnable night mode

    Outdoor PCB automatically memorises the time whenthe peak outdoor temperature appears. It enablesquiet operation mode after 8 h*1, and returns tonormal mode after it keeps this on for 9 h*2.

    *1 8 h is the initial setting with 6 h or 10 h also available.*2 9 h is the initial setting with 8 h or 10 h also available.

    Notes: This function is available in setting at site.

    The operating sound in quiet operation mode is the actual valuemeasured by our company.

    The relationship of outdoor temperature (load) and time shownabove is just an example.

    Streamlined air grille

    It promotes the discharge ofswirling airflow, furtherreducing thepressure loss.

    Streamlined scroll fanThe sharp edge of each fan blade

    has a certain curvature, reducingboth the vibration and the pressureloss.

    Streamlined

    scroll fan

    Illustrated

    fan

    Operating

    sound(dB)

    Load

    (%)

    Capacity

    (%) Night mode

    min. 40 dB(A)

    8 hrs

    8:00

    50

    60

    50

    100

    0

    40

    57

    12:00 16:00 20:00 0:00 4:00 8:00

    9 hrs

    VRVIVVRVIV

    6 HP 8 HP 10 HP 12 HP

    55 56 57 59

    Sound level(dB(A))

    Quiet night-time operation function

    Without increasing operation sound, advancedanalytic technologies are utilised to optimise fandesign, increase airflow rate and external staticpressure.

    Large airflow, high static pressure andquiet technology

    ENERGY SAVING

    EASE OF INSTALLATION

    COMFORT

    7

  • 7/24/2019 Daikin VRV Catalog 131014

    10/84

    VRT-VARIABLE REFRIGERANT

    TEMPERATURE

    STATE-OF-THE-ART ENERGY SAVING TECHNOLOGY FOR VRV SYSTEM

    How is energy reduced?During cooling, the refrigerant evaporatingtemperature (Te) is raised to minimise thedifference with the condensing temperature.During heating, the condensing temperature (Tc) islowered to minimise the difference to theevaporating temperature. Compressors work less,

    and this reduces power comsumption.

    CompressorCompressor

    (During cooling)

    Evaporator

    Condenser

    Evaporating temperature raisedCompressor workload reduced

    Indoor unitheat exchanger

    CompressorCompressor

    Evaporator

    Condenser

    Indoor unitheat exchanger

    (During heating)

    Condensing temperature lowered

    Compressor workload reduced

    Coolingload

    &capacity

    25%

    100%

    OutdoorTemp.

    35C30C25C20C

    Capacitychangesto matchheat load

    Refrigerant cycle

    Typical changes in evaporating temperature and COP depending on changing indoor load

    OutdoorTemp.

    VRT

    Without VRT

    Low

    High

    Low

    High

    35C30C25C20C

    Refrigerantevapo

    rating

    temp.

    /Te(C

    )

    Automatic control toadjust temperature

    OutdoorTemp.

    COP

    35C30C25C20C

    Without VRT

    VRT

    Low

    High

    Customise your VRV system for optimal annual efficiency

    The new VRVIVsystem now features VRT technology.VRT automatically adjusts refrigerant temperature to individualbuilding and climate requirement, thus further improvingannual energy efficiency and maintaining comfort.With this excellent technology, running costs are reduced.

    Required capacity changesas airconditioning loadchanges according tooutdoor temperature.

    Energy efficiency isimproved withoutsacrificing comfort.

    Automatic control adjustsevaporating temperatureto heat load change.

    In case of fixed evaporatingtemperature, excessive cooling,thermo on-off loss, and otherinefficiencies occur.

    8

  • 7/24/2019 Daikin VRV Catalog 131014

    11/84

    Can boost capacity above 100% if needed.The refrigerant temperature can go lower in cooling (higher in heating)than the set minimum (maximum in heating).

    Gives priority to very fast reaction speed. The refrigerant temperature goes down (or up in heating) fast to keep

    the room setpoint stable.

    Gives priority to fast reaction speed. The refrigerant temperature goes down (or up in heating) fast to keep

    the room setpoint stable.

    Gives priority to efficiency. The refrigerant temperature goes down (or up in heating) gradually giving

    priority to the efficiency of the system instead of the reaction speed.

    Mild

    mode

    Quick

    mode

    Powerfulmode

    Variable Refrigerant TemperatureFixed RefrigerantTemperature

    High Sensible Mode

    Fixed target Te

    Auto ModeFloating target Te/Tc depending on heat load

    Basic ModeFixed Te/Tc - Standard control

    (default setting on VRV IV)

    Unable to change Te

    Powerful ModePowerful Mode

    Reaction speed Very Fast

    Quick ModeQuick Mode

    Reaction speed Fast

    Mild ModeMild Mode

    Reaction speed Medium

    Eco ModeEco Mode

    Energy saving priorityCapacity priority

    40

    35

    30

    25

    20

    15

    0Mar. Jun. Sep. Dec.

    Av. max. temp. Av. daily temp. difference

    Av. min. temp.

    (Typical example)

    OutdoorTemp.(C)

    VRT is particularly effective at night whentemperatures are low.

    40

    35

    30

    25

    20

    15

    0Mar. Jun. Sep. Dec.

    Av. max. temp.

    Heatingperiod

    Heatingperiod

    Intermediateperiod

    IntermediateperiodCooling period

    Av. min. temp.

    OutdoorTemp.(C)

    Set temperature

    Very Fast Time

    30

    Start ofcooling

    25

    FastMedium

    IndoorTemp.(C)

    VRT offers quicker cool downto shorten uncomfortable pull down time.

    Mild

    Quick

    Powerful

    Floating Te/Tc Fixed Te

    (Typical example)

    Fine control to match user preference available through mode selection

    Recommended for use in these situations

    Basic mode is selected to maintain optimal comfort.

    VRT is selected to save energy and prevent excessive cooling or heating.

    Cooling only regions having differencesin daily temperature.

    Cooling/heating regions having periodsof mild outdoor temperatures.

    VRT is particularly effective during the intermediate periods.

    Selecting VRT enables operation to be optimised for

    either energy efficiency or rapid cooling/heating.

    9

  • 7/24/2019 Daikin VRV Catalog 131014

    12/84

    MORE FLEXIBLE SYSTEM DESIGN

    MORE OPTIONS FOR INSTALLATION LOCATION

    The long piping length provides more design flexibility, which can match even large-sized buildings.

    Long piping length

    For connection of only VRV

    indoor units

    Conditions of VRV indoor unit connection capacity

    Connection capacity at maximum is 200%.

    Connection ratio

    Note:

    *1 For the FXFQ25LU, and FXVQ models, maximum connection ratio is 130% for the entire range of outdoor units.

    If the operational capacity of indoor units is more than 130%, low airflow operation isenforced in all the indoor units.

    *Refer to page 47 for outdoor unit combination details.

    50%200%

    Connection ratio

    Single outdoor units

    Double outdoor units

    Triple outdoor units

    FXDQ, FXMQ-P, FXAQ models

    Applicable

    VRV indoor units

    200%

    Other VRV indoor

    unit models*1

    200%

    160%

    130%Connection ratio =Total capacity index of the indoor units

    Capacity index of the outdoor units

    1. No special requirements up to 40 m. The maximum actual piping length can be 90 m, depending on conditions. Various conditions and requirements have to be metto allow utilisation of 90 m piping length.

    2. When level differences are 50 m or more, the diameter of the main liquid piping size must be increased and connection ratio must be 80% to 130%. If the outdoor unitis above the indoor unit, a dedicated setting on the outdoor unit is required.

    Maximum

    allowablelevel difference

    Maximumallowablepiping length

    Between the outdoor unitsand the indoor units

    Between the indoor units

    Between the outdoor units (Multiple use)

    Between the first indoor branch and the farthest indoor unit

    Between the outdoor branch and the last outdoor unit

    Total piping length

    Refrigerant piping length

    30m

    5m

    90m

    q

    s

    r

    r

    a+b+c+d+e+f+g+h+i

    a+f+g+h+i

    f+g+h+i

    k+p

    165m 190m

    1000m

    10m 13m

    Actualpiping length

    Equivalentpiping lengthExample

    LevelDifference

    Example

    If the outdoor unit is above.

    If the outdoor unit is below.

    p

    q

    k

    First outdoor branch

    fa

    b

    Firstindoor branch

    Multiple use

    *The rest of indoor units are the same as for single use.

    90m*1

    90m 2

    Max.

    30m

    Max.

    90m

    165m

    190m

    1000m

    Max. equivalent piping length

    90m 2

    Max. actual piping length

    Max. total piping length

    30mMax. level differencebetween the indoor units

    Max. level differencebetween the outdoor unitsand the indoor units

    a

    i

    s

    r

    hgf

    edcbFirst indoor branch

    Single use

    Colours in the diagram above are merely for identifying pipes referenced with symbols such as a .

    2

    10

  • 7/24/2019 Daikin VRV Catalog 131014

    13/84

    78.4 PaMore options in theopening/angle of louvreOutstanding heat dissipationeffect in both hierarchical andintensive arrangement

    VRVIV outdoor unit has achieved highexternal static pressure up to 78.4 Pa,ensuring the efficient heat dissipation andstable operation of equipment in eitherhierarchical or intensive arrangement.

    78.4 PaMore options in theopening/angle of louvreOutstanding heat dissipationeffect in both hierarchical andintensive arrangement

    High external static pressure

    11

  • 7/24/2019 Daikin VRV Catalog 131014

    14/84

    RELIABLE AND STABLE SYSTEM

    MULTIPLE ADVANCED FEATURES ENSURING MORE ACCURATE TESTOPERATION AND STABLE SYSTEM

    Daikin VRVIVsystem incorporates a simplified and efficient test operation function, not only greatlyaccelerating the installation process, but effectively improving the field setting quality as well.

    Efficient automatic test operation

    Automatically checks the wirings betweenoutdoor units and indoor units to confirm

    whether there is a defective wiring.

    Confirms and corrects the actual pipinglength.

    Automatically checks whether the stopvalve in each outdoor unit is in normalstatus to ensure the smooth operation ofairconditioning system.

    Automatic check

    Wiringcheck

    Pipingcheck

    Stop valve

    check

    SIMPLIFIED COMMISSIONING AND AFTER-SALES SERVICE

    VRVIVsystem utilises the 7-segmentluminous digital tubes to display systemoperation information, enabling theoperational state to be visually displayedwhilst facilitating simplifiedcommissioning and after-sales service.

    Function of information displayby luminous digital tube

    The VRVconfigurator is an advanced software solutionthat allows for easy system configuration andcommissioning.

    Less time is required on the roof configuring the outdoorunit.

    Multiple systems at different sites can be managed inexactly the same way, thus offering simplifiedcommissioning for key accounts.

    Initial settings on the outdoor unit can be easily retrieved.

    VRVconfigurator

    Simplifiedcommissioning

    Retrieve initial

    system settings

    Displayssystemoperationinformationdirectly

    Figures outsystemoperationinformation byreading lightemitting stateof differentdiodes, whichis bothinefficient and

    fallible.

    7-segment digital display Conventional LED display

    12

  • 7/24/2019 Daikin VRV Catalog 131014

    15/84

    OUTDOOR UNIT SEQUENCING TECHNOLOGY

    DOUBLE BACKUP OPERATION FUNCTIONS RESPONDING RESILIENTLY TOVARIOUS UNEXPECTED SITUATIONS

    Automatic sequencing operation

    During start-up, the Daikin VRV IVunit sequencing operation will be automatically enabled toensure balanced operation of each outdoor unit to improve longevity of equipment and stable operation.

    Stage 1 Stage 2 Stage 3

    Priority: Priority: Priority:

    AutomaticsequencingAutomatic

    sequencingAutomatic

    sequencingAutomatic

    sequencing

    Daikin VRVIVsystem boasts double backup operation functions, which can secure the use of airconditioners in this area to the greatest extent by emergently enabling double backup operation functionseven if failure occurs in a set of airconditioning equipment.In the event of a failure, emergency operation can be conveniently enabled to allow the remaining systemto operate in a limited fashion.

    Double backup operation functions

    Unit backup operation function

    If malfunction occurs in an outdoor unit...Emergency operation can be conveniently set and enabled

    by the remote controller for indoor unit (for systemscomposed of two or more outdoor units).

    If malfunction occurs in a compressor...Emergency operation can be easily set andenabled by the outdoor unit (for a single outdoorunit system RX(Y)Q14-20TRY6 models).

    Compressor backup operation function

    13

  • 7/24/2019 Daikin VRV Catalog 131014

    16/84

    ADVANCED TECHNOLOGIES ACHIEVE

    LARGE CAPACITY ALL DC INVERTER COMPRESSOR IN COMPACT CASING

    HIGHLY INTEGRATED HEAT EXCHANGER

    Large capacity inverter compressor using high tension strength material,realise 12 HP compressor using 8 HP casing.

    Small sizing coil end using concentratedwinding, reduces copper loss(winding resistance).

    Improves motor efficiency in low rpmrange (improves intermediate

    efficiency).

    Distributed winding motor

    (Current 8 HP compressor)

    Concentrated winding motor

    (New 12 HP compressor)

    Coilend

    Gives 2.4 times tensile strength

    compared to conventional materialNew Material: 600 MPaConventional Material : 250 MPaIncreases compression chamber volumeby using thin spiral design.

    As a result of having thinned a wall -thickness of the scroll, compressionchamber volume increase 50%

    Development of highstrength material

    Small type high efficiencyconcentrated winding motor

    Improves performance by increasing heat exchanger area while maintaining the same installation space.

    Change fin shape from fine louvre to waffle fin.Fin pitch can be reduced fin pitch from 2.0 mm to 1.4 mm, to realise unit

    efficiency which increases heat exchanger area.

    Realises highly integrated heat exchanger performance

    (increase row, reduce fin pitch) by reducing of airflowresistance which changes cooling tube to 7.

    Heat exchangerarea

    Contribution of COP(cooling)

    10 HP16 HP

    13%UP 105.5%24%UP 111.5%

    Fine Louvre Fin Waffle Fin

    3 rows with small pipe design,increase heat transfer efficiency

    20 HP

    VRV

    14

  • 7/24/2019 Daikin VRV Catalog 131014

    17/84

    EXCELLENT PERFORMANCE

    VARIOUS ADVANCED CONTROL MAIN PC BOARD

    Computer control board SMTpackagingmaterial

    *SMT: Surface mounted technology

    Computer control board surface

    adopting SMT packagingtechnology

    Conventionalcomputer control

    board surface

    SMT packaging technology adopted by thewhole computer control panel improves theanti-clutter performance.

    Protects your computer boards from adverseeffects of sandy and humid weather.

    SMT* packaging technology

    Downsizes electric component, relocates to deadspace of bell mouth side to decrease airflow resistance.

    Refrigerant cooling technology, ensures stability of PCB temperature

    Improves reliability at high ambient temperatureIt is possible to cool the inverter power module stability even at high ambient temperature.This helps to keep airconditioning capacity and also ensures efficient and reliable operation.

    Bell mouth

    Electric Component Space

    VRV

    Improved inner design to increase smooth airflow

    15

  • 7/24/2019 Daikin VRV Catalog 131014

    18/84

    OUTDOOR UNIT LINEUP

    The outdoor unit capacity is up to 60 HP in increment of 2 HP.

    VRVIVoutdoor unit offers a higher capacity of up to 60 HP, responding to the needs of large-sized buildings.

    The single outdoor unit has only 2 different shapes and dimensions, not only simplifying the design process, but also bringing the

    system flexibility to a new level.

    With the outdoor unit capacity increased in increment of 2 HP, customers' needs can be precisely met.

    Outdoor units with anti-corrosion specifications (-E type on request) are designed specifically for use in areas which are subject to

    salt damage and atmospheric pollution.

    Normal (Space Saving) Type

    RX(Y)Q22TRY6RX(Y)Q24TRY6

    22, 24 HP

    Double Outdoor Units

    RX(Y)Q6TRY6(E)RX(Y)Q8TRY6(E)RX(Y)Q10TRY6(E)RX(Y)Q12TRY6(E)

    RX(Y)Q14TRY6(E)RX(Y)Q16TRY6(E)

    6, 8, 10, 12 HP 14, 16 HP

    RX(Y)Q18TRY6(E)RX(Y)Q20TRY6(E)

    18, 20 HP

    Single Outdoor Units

    26, 28, 30, 32 HP

    RX(Y)Q26TRY6RX(Y)Q28TRY6

    RX(Y)Q30TRY6RX(Y)Q32TRY6

    RX(Y)Q42TRY6RX(Y)Q44TRY6

    RX(Y)Q46TRY6RX(Y)Q48TRY6RX(Y)Q50TRY6RX(Y)Q52TRY6RX(Y)Q54TRY6RX(Y)Q56TRY6RX(Y)Q58TRY6RX(Y)Q60TRY6

    Triple Outdoor Units

    34, 36, 38, 40 HP

    Double Outdoor Units

    46, 48, 50, 52, 54, 56, 58, 60 HP42, 44 HP

    RX(Y)Q34TRY6RX(Y)Q36TRY6

    RX(Y)Q38TRY6RX(Y)Q40TRY6

    Lineup

    HP

    Normal (SpaceSaving) Type

    OUTDOOR UNITS

    16

  • 7/24/2019 Daikin VRV Catalog 131014

    19/84

    INDOOR UNIT LINEUP

    HEAT PUMPENHANCED RANGE OF CHOICES

    FXVQ-MY1

    FXVQ-MY16(high static pressure type)

    A variety of VRV indoor units are enabled in one system, opening the door to stylishand quiet indoor units.

    VRVindoor units

    Type Model Name

    15 types 79 models

    FXMQ-MVE

    FXFQ-SVM

    17

  • 7/24/2019 Daikin VRV Catalog 131014

    20/84

    INDOOR UNIT LINEUP

    Ceiling Mounted Cassette(Round Flow with Sensing)Type (Optional)

    Presence of people and floortemperature can be detected toprovide comfort and energy savings

    FXFQ-SVM

    At Daikin, we offer a wide range of indoor units, including both VRVandresidential models, responding to a variety of needs of our customers thatrequire airconditioning solutions.

    Ceiling Mounted Cassette(Compact Multi Flow)Type

    Quiet, compact, and designed foruser comfort

    4-Way Flow CeilingSuspended Type

    Ceiling Mounted Cassette(Round Flow) Type

    FXFQ-LUV1

    360 airflow improves temperaturedistribution and offers a comfortableliving environment.

    This slim and stylish indoor unitachieves optimum air distribution,and can be installed without theneed for ceiling cavity.

    Ceiling Mounted Cassette(Double Flow) Type

    Thin, lightweight, and easy to installin narrow ceiling spaces

    Ceiling Mounted CassetteCorner Type

    Slim design for flexibleinstallation

    Slim Ceiling Mounted DuctType

    Slim design, quietness andstatic pressure switching

    Ceiling Mounted DuctType

    High external static pressureallows flexible installations

    FXDQ-PBVE

    FXDQ-NBVE

    FXMQ-PVE

    FXMQ-MAVE

    FXZQ-MVE

    FXCQ-MVE FXKQ-MAVE

    FXUQ-AVEB

    VRVIndoor Units

    18

  • 7/24/2019 Daikin VRV Catalog 131014

    21/84

    Floor Standing Type

    Concealed Floor StandingType

    Suitable for perimeter zone air conditioning

    FXLQ-MAVE

    FXNQ-MAVE

    Ceiling Suspended Type

    Slim body with quiet and wideairflow

    FXHQ-MAVE

    Floor Standing Duct Type

    FXVQ-MY1FXVQ-MY16

    Large airfiow type for large spaces.Flexible interior design for each tenant.

    (high static pressure type)

    Wall Mounted Type

    Stylish flat panel designharmonised with your interiordcor

    FXAQ-PVE

    19

  • 7/24/2019 Daikin VRV Catalog 131014

    22/84

    INDOOR UNIT LINEUP

    VRV INDOOR UNITS

    FXFQ25S / FXFQ32S / FXFQ40S

    FXFQ50S / FXFQ63S / FXFQ80S

    FXFQ100S / FXFQ125S

    Dual sensors detect the presence of people and floor temperature

    to provide comfortable air-conditioning and energy savings.

    Thanks to the individual airflow direction control function, airflowdirection can be individually adjusted for each air dischargeoutlet. Five directions of airflow and auto-swing can be selectedwith wired remote controller BRC1E62, which realises optimumair distribution.

    Presence of people and floor temperature can bedetected to provide comfort and energy savings

    Infrared presence sensor

    Ceiling Mounted Cassette (Round Flow with Sensing) Type (Optional)

    Presence ofpeople in 4areas

    Detecting theaveragetemperature ofindoor floor

    Infrared floor sensor

    Individual airflow direction control

    The sensor detects the floor temperature and automaticallyadjusts operation of the indoor unit to reduce the temperaturedifference between the ceiling and the floor.

    Indoor unit offers 360 airflow, discharges air in alldirections with more uniform temperature distribution.

    Dead spot of airflow

    Control of airflow rate can be selected from 3-stepcontrol, which provides comfortable airflow. Auto airflowrate control can be selected with wired remote controllerBRC1E62.

    Low operation sound level

    45/40/35

    125

    44/38/32

    100

    38/35/31

    80

    38/33/28

    63

    36/32/28

    50

    31/29/27

    4025/32

    30/28.5/27Soundlevel

    (H/M/L)

    FXFQ-S

    Drain pump is equipped asstandard accessory with 850 mmlift.

    850 mm

    Energy efficiency has been improved thanks to theadoption of a new heat exchanger with smaller tubes,DC fan motor and DC drain pump motor.

    The sensor detects human presence and adjuststhe airflow direction automatically to prevent drafts.Energy saving control can be performedwhen no people are detected.

    Position 0 Position 2

    Position 3 Swing

    Individual airflow direction example case

    20

  • 7/24/2019 Daikin VRV Catalog 131014

    23/84

    *3

    When there are no people in a room,the set temperature is shifted automatically.

    If people do not return, the air conditioner will raise thetemperature 1C every 30 minutes and then operate at 30C.

    Example: Cooling setpoint: 26C Shift temperature: 1.0C

    Shift time: 30 min. Limit cooling temperature: 30C

    Shift temperature and time can be selected from 0.5 to 4C in 0.5C incrementsand 15, 30, 45, 60, 90 or 120 minutes respectively with remote controller.

    Sensing sensor stop mode

    *2. User can set these functions with remote controller.

    *1. These functions are not available when using the group control system.

    *1. 2

    When there are no people in a room, the systemstops automatically.

    Absent stop time can be selected from 1 to 24 hrs in 1 hrincrements with remote controller.

    Sensing sensor low mode *1. 2

    New airflow block function preventsuncomfortable drafts by reducing air velocity.It can be set using the BRC1E62 remote controller.There is no need for sealing material of air dischargeoutlet (option).

    This function only works when all-round flowis used. It cannot be used when sealing material isused in the air discharge outlet (option).

    Total comfort by individual airflow direction controland newly-equipped airflow block function

    Also can supportthis case

    Airflow blockfor cabinet side

    Airflow blockair velocityapprox. 0.3m/s*4

    Airflow block function prevents uncomfortabledrafts by reducing air velocity to approx. 0.3m/s.*4

    Airflow blockHorizontal flow

    *4. In case of FXFQ63S type (Data is based on Daikin research.)

    *3. Works in one direction only.

    Easy setup with remote controller

    500mm

    Wall

    Airflowblock

    *5

    *5. A gap of 1500 mm is required if the air block function is not used.

    The airflow block function isuseful when rearranging theroom layout.

    Sensing function

    Auto airflow rate mode + Auto airflow direction mode

    Floor temperature is detected and over cooling prevented.

    Energy savings

    The temperature near the person is automatically calculated bydetecting the temperature of the floor. Energy is saved, because

    the area around the feet does not get too cold.

    Comfortable airflowAirflow rate automatically increases during hot or cold periods (when thereis a large difference with set temperature), and operation is rapidlyperformed for cooling or heating.When the difference with set temperaturebecomes small, drafts are prevented by automatically reducing airflow rate,and raising the flap to a horizontal position during the cooling operation.

    Without sensing function

    With sensing function

    30C near ceiling

    20C near floor

    Roomtemperature isdetected as

    30C.

    Room temperature iscalculated as 27C in the area which

    is in the vicinity of the person.

    30C near ceiling

    24C near floor

    Automaticcontrol usingthe temperaturenear the personas the roomtemperature.

    The floor temperature, which is lowerthan near the ceiling, is detected.

    Area around feet getstoo cold because airconditioner continuesuntil the temperaturenear the ceiling reachesthe set temperature.

    Sensing sensor mode

    Airflow block function

    28

    27

    26

    OccupiedUnoccupied

    Automaticallyreverts whenpeople return.

    27C

    28C

    26C26C 26C26C

    27C

    28C

    Setpoint(C)

    TimeAfter 30 min After another 30 min

    21

  • 7/24/2019 Daikin VRV Catalog 131014

    24/84

    INDOOR UNIT LINEUP

    VRV INDOOR UNITS

    360 airflow improves temperature distributionand offers a comfortable living environment.

    Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to close each unused outlet.

    3-way flow L-shaped 2-way flowAll-round flow 4-way flow

    The industrys first* Round Flow Ceiling Mounted

    Cassette type offers 360airflow with improved

    temperature distribution.

    The light weight unit at 19.5 kg for FXFQ25-50LU

    models make installation easy.

    A modern sophisticated decoration panel has been

    applied, with a panel surface that has been treated with

    a dirt-repellant coating. An antibacterial treatment that uses silver ions has

    been applied to the drain pan, preventing the growth

    of slime, mould and bacteria that cause blockagesand odours.

    The horizontal louvres prevent dew condensation.

    Their non-flocking surfaces, which repel dirt, are

    easy to clean.

    The air filter has an anti-mould and antibacterial

    treatment that prevents the growth of mould

    generated from dust or moisture that may adhere to

    the filter.

    Example of airflow patterns:All-round flow is available, as well as 2-way to

    4-way flows, so you can choose the most

    suitable airflow pattern depending on location orroom layout.

    Drain pump is equipped as a

    standard accessory with a 850 mm

    lift.

    Treated surface Untreated surface

    Resistssoiling

    Condition afterexposure to thesmoke of 600cigarettes in 1 m

    3

    enclosed space.

    Dirt andgrime

    Control of the airflow rate can be selected from 3-step

    control.

    4-way flowRound Flow

    There are areas ofuneven temperature.

    There are much fewerareas of uneven temperature.

    * As of April 2004, the release date for Japan.

    Low operation sound level (dB(A))

    44/39/34

    125

    43/37.5/32

    100

    36/33.5/31

    80

    34/31/28

    63

    32/29.5/27

    50

    31/29/27

    4025/32

    30/28.5/27Soundlevel

    (HH/H/L)

    FXFQ-LU

    850 mm

    Ceiling Mounted Cassette (Round Flow) Type

    FXFQ25LU / FXFQ32LU / FXFQ40LU

    FXFQ50LU / FXFQ63LU / FXFQ80LU

    FXFQ100LU / FXFQ125LU

    22

  • 7/24/2019 Daikin VRV Catalog 131014

    25/84

    Quiet, compact, and designed for user comfort

    Dimensions correspond with 600 mm X 600 mm

    architectural module ceiling design specifications.

    Wide discharge angle: 0 to 60

    2-, 3-, and 4-way airflow patterns are available,

    enabling installation in the corner of a room.

    0

    60

    0

    60

    Auto swing

    Fixed angles: 5 levels

    *Angles can be also set on site t o prevent drafts (0-35)or soiling of the ceiling (25-60), other than standard setting (0-60).

    750 mm

    4-way flow 3-way flowL-shaped

    2-way flow

    1

    2

    0 0

    60 60

    Comfortable airflow

    Drain pump is equipped as standard accessory with

    750 mm lift.

    *For 3-way or 2-way flow installation, the sealing member for air discharge outlet(option) must be used to close each unused outlet.

    Ceiling Mounted Cassette (Compact Multi Flow) Type

    FXZQ20M / FXZQ25M / FXZQ32M

    FXZQ40M / FXZQ50M

    Low operation sound level(dB(A))

    32/2930/25

    20/25 32 4040 5050

    33/2932/26 36/3036/28 41/3441/33

    FXZQ-M

    Sound level(H/L)

    Sound level(H/L)

    23

  • 7/24/2019 Daikin VRV Catalog 131014

    26/84

    INDOOR UNIT LINEUP

    VRV INDOOR UNITS

    This slim and stylish indoor unit achieves

    optimum air distribution, and can be installed

    without a ceiling cavity.Unit body and suction paneladopted round shapes andrealised a slim appearancedesign. The unit can be usedfor various locations such asthe ceilings with no cavity andbare ceilings.

    Flaps close automatically whenthe unit stops, which gives asimple appearance.

    Unified slim height of 198 mmfor all models that gives theunified impression even whenmodels with different capacitiesare installed in the same area.

    Built-in electronic expansion valve eliminates the needfor a BEV unit, which improves flexibility of installation.

    With adoption of the individual flap control, airflowdirection adjustment can be individually set for each airoutlet. Five directions of airflow and auto-swing can beselected with wired remote controller BRC1E62, whichrealises the optimum air distribution.

    Control of the airflow rate has been improved from2-step to 3-step control. Auto airflow rate control canbe selected with wired remote controller BRC1E62.

    Energy efficiency has been improved, thanks to theadoption of a new heat exchanger with smaller

    tubes, DC fan motor and DC drain pump motor.

    Drain pump is equipped as a standard accessory, and the

    lift height has been improved from 500 mm to 600 mm.

    Depending on the installation site requirements orroom conditions, 2-way, 3-way and 4-way dischargepatterns are available.

    4-way flow 3-way flow

    L-shaped 2-way flow

    198 mm

    BEV unit isnot needed

    BEV unit isneeded

    Current model New model

    4-Way Flow Ceiling Suspended Type

    Position 0 Position 2

    Position 3 Swing

    Individual airflow direction example case

    FXUQ71A / FXUQ100A

    24

  • 7/24/2019 Daikin VRV Catalog 131014

    27/84

    Thin, lightweight, and easy to install innarrow ceiling spaces

    305 mm

    The thin unit (only 305 mm high) can be installed in a

    ceiling space as narrow as 350 mm. All models feature a

    compact design with a depth of only 600 mm.

    (When a high-efficiency filter is attached, the unit's height is400 mm.)

    Designed with higher airflow suitable for high ceil ing

    application up to 3 metres.

    Providing 2 different settings of standard and ceiling soiling

    prevention, the auto swing mechanism realises even

    distribution of airflow and room temperature.

    Two types of optional high-efficiency filters are available

    (65% and 95%, colourimetric method).

    A long-life filter is equipped as a standard accessory.* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

    Major maintenance work can be performed by removing

    the panel. A flat-type suction grille and a detachable

    blade make cleaning easy.

    Ceiling Mounted Cassette (Double Flow) Type

    FXCQ20M / FXCQ25M / FXCQ32M

    FXCQ40M / FXCQ50M / FXCQ63M

    FXCQ80M / FXCQ125M

    Drain pump is equipped as standard accessory with

    600 mm lift.

    600 mm

    (220 V)(dB(A))Low operation sound level

    FXCQ-M 20

    32/27

    25/32

    34/28

    63

    37/32

    40/50

    34/29

    80

    39/34

    125

    44/38Sound level

    (H/L)

    25

  • 7/24/2019 Daikin VRV Catalog 131014

    28/84

    INDOOR UNIT LINEUP

    VRV INDOOR UNITS

    Ceiling Mounted Cassette Corner Type

    Slim design for flexible installation

    Main body

    Air discharge grille(Option)

    Set for front discharge using a suspended ceiling.

    Downward discharge is shut off and air is blown straight out

    (front discharge).

    Front discharge is possible with an air

    discharge unit (option), which allows the

    installation in the drop-ceiling or sagging wall.

    Single-flow type allows effective air discharge

    from corner or from drop-ceiling.

    Providing 3 different settings of standard, draft

    prevention and ceiling soiling prevention, the

    auto swing mechanism assures even

    distribution of airflow and room temperature.

    Main body

    Downward discharge

    Air discharge grille (Option)

    3

    32C 30C

    28C 26C24C

    22C

    20C

    2

    1

    0 1 2 3 4 5 6 (m)

    (m)

    500 mm

    Drain pump is equipped as standard

    accessory with 500 mm lift.

    Panel spacer20 mm

    Min.195 mm

    Slim body needs only 220 mm space above the

    ceiling. If you use a panel spacer (option), the

    unit can be installed in the minimum space of

    195 mm.

    A long-life filteris equipped as a standard

    accessory.

    * 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

    FXKQ25MA / FXKQ32MA

    FXKQ40MA / FXKQ63MA

    26

  • 7/24/2019 Daikin VRV Catalog 131014

    29/84

    Slim design, quietness andstatic pressure switching

    Only 200 mm in height, this model can be installed in

    rooms with as little as 240 mm depth between the

    drop-ceiling and ceiling slab.

    Only 700 mm in width and 23 kg in weight, this

    model is suitable for installation in limited

    spaces like drop-ceilings in hotels.

    * The values of operation sound level represent those for rear-suction operation.Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).

    * Values are based on the following conditions:

    FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure

    of 15 Pa.

    * 1,100 mm in width for the FXDQ63NB model.

    200 mm900mm

    Suction grille *AIR

    AIR

    Discharge grille *

    Air filterSuspension bolt*

    240mm

    * To be obtained locally

    Only700mm200mm

    Great for

    hotel use!

    Suited to use in drop-ceilings!

    750 mm

    Ceiling

    Control of the airflow rate has been improved from 2-step

    to 3-step control.

    Slim Ceiling Mounted Duct Type

    FXDQ20PB / FXDQ25PB / FXDQ32PB FXDQ40NB / FXDQ50NB / FXDQ63NB

    Low operation sound level (dB(A))

    36/34/3236/34/32

    6363

    35/33/31

    50

    34/32/30

    40

    33/31/29

    20/25/32

    Sound level(HH/H/L)

    FXDQ-PB/NB

    External static pressure selectable by remote controllerswitching make this indoor unit a very comfortable andflexible model.

    10 Pa-30 Pa/factory set: 10 Pa for FXDQ-PB models.15 Pa-44 Pa/factory set: 15 Pa for FXDQ-NB models.

    FXDQ-PB and FXDQ-NB models are available with adrain pump as a standard accessory.

    FXDQ-PB/NBVE: with a drain pump (750 mm lift)as a standard accessory

    27

  • 7/24/2019 Daikin VRV Catalog 131014

    30/84

    INDOOR UNIT LINEUP

    VRV INDOOR UNITS

    Ceiling Mounted Duct Type

    Middle and high static pressureallows for flexible duct design

    All models are only 300 mm in height, animprovement over the 390 mm height ofconventional models. The weight of theFXMQ40P has been reduced from 44 kg to 28 kg.

    A DC fan motor increases the external staticpressure capacity range to include middle to highstatic pressures, increasing design flexibility.

    Simplified Static Pressure ControlExternal static pressure can be easily adjusted usinga change-over switch inside the electrical box to meetthe resistance in the duct system.

    FXMQ200MA/FXMQ250MA

    Drain pump is equipped asstandard accessory with700 mm lift.

    Control of the airflow rate has been improvedfrom 2-step to 3-step control.

    (dB(A))

    46/45/43

    140

    42/40/38

    63

    43/41/39

    80/100

    41/39/37

    50

    39/37/35

    40

    34/32/30

    32

    33/31/29

    20/25

    Soundlevel

    (HH/H/L)

    FXMQ-P

    700 mm

    Ceiling

    30 Pa100 Pa for FXMQ20P-32P30 Pa160 Pa for FXMQ40P

    50 Pa200 Pa for FXMQ50P-125P50 Pa140 Pa for FXMQ140P

    Low operation sound level

    Improved ease of installation

    Improved ease of maintenance

    Airflow rate can be controlled using a remote controller during

    test operations. With the conventional model, the airflow rate

    was controlled from the PC board. It is automatically adjusted to

    the range between approximately 10% of the rated HH tap

    airflow for FXMQ20P125P.

    The drain pan can be detached for easy cleaning. An

    antibacterial treatment that uses silver ions has been applied to

    the drain pan, preventing the growth of slime, mould and

    bacteria that cause blockages and odours.

    Energy-efficient

    The adopted DC fan motor is much more efficient than

    the conventional AC motor, yielding an approximate

    20% decrease in energy consumption (FXMQ125P).

    44/42/40

    125

    FXMQ20P / FXMQ25P / FXMQ32P

    FXMQ40P / FXMQ50P / FXMQ63P

    FXMQ80P / FXMQ100P / FXMQ125P

    FXMQ140P

    28

  • 7/24/2019 Daikin VRV Catalog 131014

    31/84

    Slim body with quiet and wide airflow

    Adoption of QUIET STREAM FAN

    Drain pump kit (option) can be easily incorporated.

    Easy-to-clean flat design

    Maintenance is easier because everything can be

    performed from below the unit.

    Non-dew flap with no implanted bristles

    Uses the quiet stream fan and manymore advanced technologies.

    Sound absorptionmember

    Turbulent flowis produced

    Straightening vane

    Quiet stream fan

    Installation is easy

    Maintenance is easy

    Drain pump kit(built inside main unit)

    600mm

    Bristle-free flap minimisescontamination and makescleaning simpler.

    Non-dew Flap

    100

    Wide air discharge openings produce a spreading 100

    airflow.

    A long-life filter is equipped as standard accessory.* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

    Ceiling Suspended Type

    FXHQ32MA / FXHQ63MA

    FXHQ100MA

    FXHQ-MA

    Sound level(H/L)

    Sound level(H/L)

    3232

    36/3136/31

    6363

    39/3439/34

    100100

    45/3745/37

    (dB(A))Low operation sound level

    29

  • 7/24/2019 Daikin VRV Catalog 131014

    32/84

    INDOOR UNIT LINEUP

    VRV INDOOR UNITS

    Stylish flat panel design harmonised

    with your interior dcor

    Drain pan and air filter can be kept clean by mould-proof

    polystyrene.

    Vertical auto-swing realises efficiency of air distribution.

    The louvre closes automatically when the unit stops.

    5 steps of discharge angle can be set by remotecontroller.

    Discharge angle is automatically set at the same angle

    as the previous operation when restarting. (Initial setting:

    10 for cooling and 70 for heating)

    Flexible installation

    Drain pipe can be fitted to it from either left or

    right sides.

    Stylish flat panel design creates a graceful harmony that

    enhances any interior space.

    Flat panel can be cleaned with only the single pass of a

    cloth across their smooth surface.

    Flat panel can also be easily removed and washed for

    more thorough cleaning.

    Wall Mounted Type

    Drain pump kit is available as optional accessory, which

    lifts the drain 1,000 mm from the bottom of the unit.

    Drain pump kit

    1,000 mm

    Height of drain-up

    Indoor unit

    FXAQ20P / FXAQ25P

    FXAQ32P / FXAQ40P

    FXAQ50P / FXAQ63P

    Low operation sound level(dB(A))

    47/4147/41

    6363

    42/3742/37

    5050

    39/3439/34

    4040

    38/3138/31

    3232

    36/3136/31

    2525

    35/3135/31

    2020

    Sound level(H/L)

    Sound level(H/L)

    FXAQ-PFXAQ-P

    30

  • 7/24/2019 Daikin VRV Catalog 131014

    33/84

    Suitable for perimeter zone airconditioning

    Wall hanging Floor installation

    Floor Standing types can be hung on the wall for easier

    cleaning. Running the piping from the back allows the

    unit to be hung on walls. Cleaning under the unit, where

    dust tends to accumulate, is considerably easier.

    A long-life filter is equipped as standard accessory.* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

    The adoption of a fibre-less discharge grille, featuring an

    original design to prevent condensation, also helps

    prevent staining and makes cleaning easier.

    Designed to be concealed in the perimeter skirting-wall

    Connectingport

    Refrigerantpiping

    * Applies also to Floor Standing type (FXLQ-MA).

    The unit is concealed in the skirting-wall of the perimeter,

    that creates a classy interior design.

    The connecting port faces downwards,

    greatly facilitating on-site piping work.

    A long-life filter is equipped as a

    standard accessory.* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

    Floor Standing Type

    Concealed Floor Standing Type

    FXNQ20MA / FXNQ25MA

    FXNQ32MA / FXNQ40MA

    FXNQ50MA / FXNQ63MA

    FXLQ20MA / FXLQ25MA

    FXLQ32MA / FXLQ40MA

    FXLQ50MA / FXLQ63MA

    31

  • 7/24/2019 Daikin VRV Catalog 131014

    34/84

    INDOOR UNIT LINEUP

    VRV INDOOR UNITS

    FXVQ125M / FXVQ200M

    FXVQ250M / FXVQ400M

    FXVQ500MY16

    Floor Standing Duct Type

    Large airflow type for large spaces.Flexible interior design for each customer.

    Large airflow type that fits for spacious areas such as factoriesand large stores.

    Various installations can be supported from full-scale ductconnection airflow to direct airflow that allows for easyinstallation.

    The high static pressure type driven by the belt drivesystem allows for use of air discharge outlets in variousshapes as well as long ducts. Highly flexible installationis possible.

    High maintainability design that allows major servicesand maintenance services to be performed at the front.

    A long-life filter is equipped as a standard accessory.* 8 hr/day, 26 day/month. For dust concentration of 0.15 mg/m3

    A wide range of optional accessories are available suchas high-efficiency filters.

    Outdoor air intake mode isuseable as an outdoor-airprocessing airconditioner.

    *When using the unit as an outdoor-airprocessing unit, there are somerestrictions.

    All-fresh (using outdoor air only) system Return + Outdoor air mixed system

    OutsideAirconditioning

    Outdoor airintroduction

    Airconditioning

    Circulatedair

    Outdoor airintroduction

    Outside

    * Air introduced from the outside and circulated air must be mixed in theair conditioner primary side before introduction into the air conditioner.

    Adding the plenum chamber (option)allows for simple operation with directairflow.* Note that the operation sound increases by

    approximately 5 dB(A).

    Direct airflow type

    Full-scale duct connection airflowallows for airconditioning evenly inspacious areas.

    Duct connection airflow type32

  • 7/24/2019 Daikin VRV Catalog 131014

    35/84

  • 7/24/2019 Daikin VRV Catalog 131014

    36/84

    SPECIFICATIONS

    VRV INDOOR UNITS

    Ceiling Mounted Cassette (Round Flow) Type

    1-phase, 220-240 V, 50 Hz

    2,400

    9,600

    2.8

    2,800

    10,900

    3.2

    3,100

    12,300

    3.6

    3,400

    13,600

    4.0

    3,900

    15,400

    4.5

    4,300

    17,100

    5.0

    4,800

    19,100

    5.6

    5,400

    21,500

    6.3

    13/11.5/10

    459/406/353

    30/28.5/27

    15/13/11

    530/459/388

    31/29/27

    16/13.5/11

    565/477/388

    32/29.5/27

    FXFQ25LUV1 FXFQ32LUV1 FXFQ40LUV1 FXFQ50LUV1

    Galvanised steel plate

    6,100 7,700 9,600 12,000

    24,200 30,700 38,200 47,800

    7.1 9.0 11.2 14.0

    6,900

    27,300

    8.0

    8,600

    34,100

    10.0

    10,800

    42,700

    12.5

    13,800

    54,600

    16.0

    19/16.5/13.5

    671/583/477

    34/31/28

    32/26/20

    1,130/918/706

    43/37.5/32

    33/28/22.5

    1,165/989/794

    44/39/34

    21/18/15

    742/636/530

    36/33.5/31

    FXFQ63LUV1 FXFQ80LUV1 FXFQ100LUV1 FXFQ125LUV1

    9.5

    15.9

    VP25 (External Dia, 32/Internal Dia, 25)

    BYCP125K-W1

    Fresh white

    50X950X950

    5.5

    6.4

    12.7

    13/11.5/10

    459/406/353

    30/28.5/27

    cfm

    dB(A)

    mm

    kg

    mm

    mm

    kg

    m3/min

    kcal/h

    Btu/h

    kW

    kcal/h

    Btu/h

    kW

    Liquid (Flare)

    Gas (Flare)

    Drain

    Model

    Colour

    Dimensions(HWD)

    Weight

    Casing

    Sound level (HH/H/L)

    Dimensions (HWD)

    Machine weight

    Pipingconnections

    Panel(Option)

    Power supply

    Heating capacity

    Cooling capacity

    MODEL

    Airflow rate (HH/H/L)

    22 25

    246X840X840 288X840X840

    19.5

    Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.

    Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.

    Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.During actual operation, these values are normally somewhat higher as a result of ambient conditions.

    Ceiling Mounted Cassette (Round Flow with Sensing) Type (Optional)

    Fresh white

    50950950

    5.5

    19

    246840840 288840840

    Galvanised steel plate

    1-phase, 220- 240 V, 50 Hz

    441/406/353

    30/28.5/27

    12.5/11.5/10.0

    2.8

    2,800

    10,900

    3.2

    9,600

    2,400

    FXFQ25SVM

    441/406/353

    30/28.5/27

    12.5/11.5/10.0

    3.6

    3,400

    13,600

    4.0

    12,300

    3,100

    FXFQ32SVM

    512/459/388

    31/29/27

    14.5/13.0/11.0

    4.5

    4,300

    17,100

    5.0

    15,400

    3,900

    FXFQ40SVM

    23

    777/618/477

    36/32/28

    22.0/17.5/13.5

    5.6

    5,400

    21,500

    6.3

    19,100

    4,800

    FXFQ50SVM

    BYCQ125B-W1

    6.4

    12.7

    I.D. 25O.D. 32(VP25)

    15.9

    9.5

    7.1

    6,900

    27,300

    8.0

    24,200

    6,100

    FXFQ63SVM

    830/653/477

    38/33/28

    23.5/18.5/13.5

    11.2

    10,800

    42,700

    12.5

    38,200

    9,600

    FXFQ100SVM

    1,165/918/671

    44/38/32

    33.0/26.0/19.0

    9.0

    8,600

    34,100

    10.0

    30,700

    7,700

    FXFQ80SVM

    830/688/530

    38/35/31

    23.5/19.5/15.0

    14.0

    13,800

    54,600

    16.0

    47,800

    12,000

    FXFQ125SVM

    1,218/971/741

    45/40/35

    34.5/27.5/21.0

    26

    cfm

    dB(A)

    mm

    kg

    mm

    mm

    kg

    kcal/h

    Btu/h

    kW

    kcal/h

    Btu/h

    kW

    Liquid (Flare)

    Gas (Flare)

    Drain

    Model

    Colour

    Dimensions(HWD)

    Weight

    Casing

    m3/min

    Sound level (H/M/L)

    Airflow rate (H/M/L)

    Dimensions (HWD)

    Machine weight

    Pipingconnections

    Panel(Option)

    Power supply

    Heating capacity

    Cooling capacity

    MODEL

    34

  • 7/24/2019 Daikin VRV Catalog 131014

    37/84

    Ceiling Mounted Cassette (Compact Multi-Flow) Type

    4-way Flow Ceiling Suspended Type

    Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.

    Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.

    Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.During actual operation, these values are normally somewhat higher as a result of ambient conditions.

    1-phase, 220-240 V/220 V, 50 Hz

    1,900

    7,500

    2.2

    2,200

    8,500

    2.5

    2,400

    9,600

    2.8

    2,800

    10,900

    3.2

    3,100

    12,300

    3.6

    3,400

    13,600

    4.0

    3,900

    15,400

    4.5

    4,300

    17,100

    5.0

    4,800

    19,100

    5.6

    5,400

    21,500

    6.3

    Galvanised steel plate

    9/7 9.5/7.5 11/8 14/10

    318/247 335/265 388/282 493/353

    30/25 32/26 36/28 41/33

    286575575

    18

    6.4

    12.7

    VP20 (External Dia, 26/Internal Dia, 20)

    BYFQ60B8W1

    White (6.5Y9.5/0.5)

    55700700

    2.7

    FXZQ20MVE FXZQ25MVE FXZQ32MVE FXZQ50MVEFXZQ40MVE

    1-phase, 220-240 V/220-230 V, 50 Hz

    6,900 9,600

    27,300 38,200

    8.0

    7,700

    30,700

    9.0

    11.2

    10,800

    42,700

    12.5Fresh white

    22.5/19.5/16 31/26/21

    794/688/565 1,094/918/741

    40/38/36 47/44/40

    198950950

    26 27

    9.5

    15.9

    VP20 (External Dia, 26/Internal Dia, 20)

    FXUQ71AVEB FXUQ100AVEB

    Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.

    cfm

    dB(A)

    mm

    kg

    mm

    mm

    kg

    kcal/h

    Btu/h

    kW

    kcal/h

    Btu/h

    kW

    Liquid (Flare)

    Gas (Flare)

    Drain

    Model

    Colour

    Dimensions(HWD)

    Weight

    Casing

    Dimensions (HWD)

    Machine weight

    Pipingconnections

    Panel(Option)

    Power supply

    Heating capacity

    Cooling capacity

    MODEL

    cfm

    dB(A)

    mm

    kg

    mm

    kcal/h

    Btu/h

    kW

    kcal/h

    Btu/h

    kW

    Liquid (Flare)

    Gas (Flare)

    Drain

    Casing

    Sound level (H/M/L)

    Dimensions (HWD)

    Machine weight

    Pipingconnections

    Power supply

    Heating capacity

    Cooling capacity

    m3/min

    MODEL

    Airflow rate (H/L)

    Airflow rate (H/M/L)

    Sound level (H/L) 230 V

    m3/min

    35

  • 7/24/2019 Daikin VRV Catalog 131014

    38/84

    SPECIFICATIONS

    VRV INDOOR UNITS

    Ceiling Mounted Cassette (Double Flow) Type

    Ceiling Mounted Cassette Corner Type

    FXCQ20MVE FXCQ25MVE FXCQ32MVE FXCQ40MVE FXCQ50MVE FXCQ63MVE FXCQ80MVE FXCQ125MVE

    1-phase, 220-240 V/220 V, 50 Hz

    1,900 2,400 3,100 3,900 4,800 6,100 7,700 12,000

    7,500 9,600 12,300 15,400 19,100 24,200 30,700 47,800

    2.2 2.8 3.6 4.5 5.6 7.1 9.0 14.0

    2,200

    8,500

    2.5

    2,800

    10,900

    3.2

    3,400

    13,600

    4.0

    4,300

    17,100

    5.0

    5,400

    21,500

    6.3

    6,900

    27,300

    8.0

    8,600

    34,100

    10.0

    13,800

    54,600

    16.0

    Galvanised steel plate

    7/5 9/6.5 9/6.5 12/9 12/9 16.5/13 26/21 33/25

    247/177 318/230 318/230 424/318 424/318 582/459 918/741 1,165/883

    32/27 34/28 34/28 34/29 34/29 37/32 39/34 44/38

    305775600 305775600 305775600 305990600 305990600 3051,175600 3051,665600 3051,665600

    26.0 26.0 26.0 31.0 32.0 35.0 47.0 48.0

    6.4 6.4 6.4 6.4 6.4 9.5 9.5 9.5

    12.7 12.7 12.7 12.7 12.7 15.9 15.9 15.9

    VP25 (External Dia, 32/Internal Dia, 25)

    BYBC32G-W1 BYBC50G-W1 BYBC63G-W1 BYBC125G-W1

    White (10Y9/0.5)

    531,030680 531,030680 531,030680 531,245680 531,245680 531,430680 531,920680 531,920680

    8.0 8.0 8.0 8.5 8.5 9.5 12.0 12.0

    FXKQ25MAVE

    9,600

    2,400

    Galvanised steel plate

    11/9

    FXKQ32MAVE

    12,300

    3,100

    FXKQ40MAVE

    15,400

    3,900

    FXKQ63MAVE

    2.8 3.6 4.5 7.1

    24,200

    6,100

    11/9 13/10 18/15

    388/318 388/318 459/353 635/530

    215X1,110X710

    31

    6.4

    12.7

    VP25 (External Dia, 32/Internal Dia, 25)

    BYK45FJW1

    White (10Y9/0.5)

    70X1,240X800

    8.5

    215X1,110X710

    31

    6.4

    12.7

    70X1,240X800

    8.5

    215X1,110X710

    31

    6.4

    12.7

    70X1,240X800

    8.5

    215X1,310X710

    34

    9.5

    15.9

    BYK71FJW1

    70X1,440X800

    9.5

    38/33 38/33 40/34 42/37

    1-phase, 220-240 V/220 V, 50 Hz

    Note: Specifications are based on the following conditions;Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.

    Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.Sound level: (FXCQ-M) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.

    (FXKQ-MA) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.During actual operation, these values are normally somewhat higher as a result of ambient conditions.

    2,800

    10,900

    3.2

    3,400

    13,600

    4.0

    4,300

    17,100

    5.0

    6,900

    27,300

    8.0

    cfm

    dB(A)

    mm

    kg

    mm

    mm

    kg

    kcal/h

    Btu/h

    kW

    kcal/h

    Btu/h

    kW

    Liquid (Flare)

    Gas (Flare)

    Drain

    Model

    Colour

    Dimensions(HWD)

    Weight

    Casing

    m3/min

    Sound level (H/L)

    Dimensions (HWD)

    Machine weight

    Pipingconnections

    Panel(Option)

    Power supply

    Heating capacity

    Cooling capacity

    MODEL

    cfm

    mm

    kg

    mm

    mm

    kg

    kcal/h

    Btu/h

    kcal/h

    Btu/h

    kW

    Liquid (Flare)

    Gas (Flare)

    Drain

    Model

    Colour

    Dimensions(HWD)

    Weight

    Casing

    m3/min

    Sound level (H/L)

    Dimensions (HWD)

    Machine weight

    Pipingconnections

    Panel(Option)

    Power supply

    Heating capacity

    Cooling capacity

    MODEL

    kW

    220 V dB(A)

    Airflow rate (H/L)

    Airflow rate (HH/M/L)

    220 V

    36

  • 7/24/2019 Daikin VRV Catalog 131014

    39/84

    Slim Ceiling Mounted Duct Type (700 mm width type)

    Slim Ceiling Mounted Duct Type (900/1,100 mm width type)

    FXDQ20PBVE FXDQ25PBVE FXDQ32PBVE

    FXDQ40NBVE FXDQ50NBVE FXDQ63NBVE

    1-phase, 220-240 V/220 V, 50 Hz

    1,900

    7,500

    2.2

    2,200

    8,500

    2.5

    2,400 3,100

    12,300

    3.6

    3,400

    13,600

    4.0

    9,600

    2.8

    2,800

    10,900

    3.2

    Galvanised steel plate

    8.0/7.2/6.4 8.0/7.2/6.4 8.0/7.2/6.4

    282/254/226 282/254/226 282/254/226

    30-10

    33/31/29 33/31/29 33/31/29

    200700620 200700620 200700620

    23.0 23.0 23.0

    6.4 6.4 6.4

    12.7 12.7 12.7

    VP20 (External Dia, 26/Internal Dia, 20)

    Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0m.Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.

    1-phase, 220-240 V/220 V, 50 Hz

    3,900 4,800 6,100

    15,400 19,100 24,200

    4.5

    4,300

    17,100

    5.0

    5.6

    5,400

    21,500

    6.3

    7.1

    6,900

    27,300

    8.0

    Galvanised steel plate

    10.5/9.5/8.5 12.5/11.0/10.0 16.5/14.5/13.0371/335/300 441/388/353 583/512/459

    44-15

    34/32/30 35/33/31 36/34/32

    200900620 200900620 2001,100620

    27.0 28.0 31.0

    6.4 6.4 6.4

    12.7 12.7 12.7

    VP20 (External Dia, 26/Internal Dia, 20)

    Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.During actual operation, these values are normally somewhat higher as a result of ambient conditions.

    1:Values are based on the following conditions: FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure of 15 Pa.2:External static pressure is changeable to set by the remote controller. This pressure means "High static pressure - Standard". (Factory setting is

    10 Pa for FXDQ-PB models and 15 Pa for FXDQ-NB models.)3: The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be

    obtained by adding 5 dB(A).

    Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.

    cfm

    Pa

    dB(A)

    mm

    kg

    mm

    kcal/h

    Btu/h

    kW

    kcal/h

    Btu/h

    kW

    Liquid (Flare)

    Gas (Flare)

    Drain

    Casing

    m3/min

    Dimensions (HWD)

    Machine weight

    Pipingconnections

    Power supply

    Heating capacity

    Cooling capacity

    MODELwith drain pump

    External static pressure

    Sound level (HH/H/L)

    cfm

    Pa

    dB(A)

    mm

    kg

    mm

    kcal/h

    Btu/h

    kW

    kcal/h

    Btu/h

    kW

    Liquid (Flare)

    Gas (Flare)

    Drain

    Casing

    m3

    /min

    Dimensions (HWD)

    Machine weight

    Pipingconnections

    Power supply

    Heating capacity

    Cooling capacity

    MODELwith drain pump

    External static pressure

    Sound level (HH/H/L)

    Airflow rate (HH/H/L)

    Airflow rate (HH/H/L)

    1 3

    1 3

    2

    2

    37

  • 7/24/2019 Daikin VRV Catalog 131014

    40/84

    SPECIFICATIONS

    VRV INDOOR UNITS

    Ceiling Mounted Duct Type

    Note: Specifications are based on the following conditions;

    Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.

    Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.

    Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.During actual operation, these values are normally somewhat higher as a result of ambient conditions.

    1: Power consumption values are based on conditions of rated external static pressure.

    2: External static pressure can be modified using a remote controller that offers seven (FXMQ20-32P), thirteen (FXMQ40P), fourteen (FXMQ50-125P) or ten (FXMQ140P) levels of control. These values indicate the lowest and highest possible static pressures. The standard staticpressure is 50 Pa for FXMQ20-32P and 100 Pa for FXMQ40-140P.

    15,400

    3,900

    565/459/388

    19,100

    4,800

    635/582/530

    4.5 5.6

    6.4

    12.7

    6.4

    12.7

    16/13/11 18/16.5/15

    7,500

    1,900

    318/265/230

    2.2

    6.4

    12.7

    9/7.5/6.5

    9,600

    2,400

    318/265/230

    2.8

    6.4

    12.7

    9/7.5/6.5

    12,300

    3,100

    335/282/247

    3.6

    6.4

    12.7

    9.5/8/7

    VP25 (External Dia, 32/Internal Dia, 25)

    24,200

    6,100

    688/618/565

    9.5

    15.9

    30,700

    7,700

    883/794/706

    9.5

    15.9

    38,200

    9,600

    1,130/953/812

    9.5

    15.9

    47,800

    12,000

    1,377/1,165/988

    9.5

    15.9

    7.1 9.0 11.2 14.0

    19.5/17.5/16 25/22.5/20 32/27/23 39/33/28

    42/40/38 43/41/39 43/41/39 44/42/40

    54,600

    13,800

    1,624/1,377/1,130

    9.5

    15.9

    16.0

    46/39/32

    46/45/43

    FXMQ20PVE FXMQ25PVE FXMQ32PVE FXMQ40PVE FXMQ50PVE

    2,200

    8,500

    2.5

    6,900

    27,300

    8.0

    8,600

    34,100

    10.0

    10,800

    42,700

    12.5

    13,800

    54,600

    16.0

    15,500

    61,400

    18.0

    2,800

    10,900

    3.2

    3,400

    13,600

    4.0

    4,300

    17,100

    5.0

    5,400

    21,500

    6.3

    300X1,000X700300X700X700300X550X700300X550X700300X550X700

    3628252525

    41/39/3739/37/3534/32/3033/31/2933/31/29

    cfm

    Pa

    dB(A)

    mm

    kg

    mm

    kcal/h

    Btu/h

    kW

    kcal/h

    Btu/h

    kW

    Liquid (Flare)

    Gas (Flare)

    Drain

    Casing

    m3/min

    Dimensions (HWD)

    Machine weight

    Pipingconnections

    Power supply

    Heating capacity

    Cooling capacity

    MODEL

    External static pressure

    Sound level (HH/H/L)

    cfm

    Pa

    dB(A)

    mm

    kg

    mm

    kcal/h

    Btu/h

    kW

    kcal/h

    Btu/h

    kW

    Liquid (Flare)

    Gas (Flare)

    Drain

    Casing

    m3/min

    Dimensions (HWD)

    Machine weight

    Pipingconnections

    Power supply

    Heating capacity

    Cooling capacity

    MODEL FXMQ63PVE FXMQ80PVE FXMQ100PVE

    1-phase, 220-240 V/220 V, 50 Hz

    Galvanised steel plate

    300X1,400X700

    46

    300X1,000X700

    36

    300X1,000X700

    36

    300X1,400X700

    46

    300X1,400X700

    47

    FXMQ125PVE FXMQ140PVE

    External static pressure

    Sound level (HH/H/L)

    Airflow rate (HH/H/L)

    Airflow rate (HH/H/L)

    230-100 (50) 230-100 (50) 230-100 (50) 230-160 (100) 250-200 (100)

    250-200 (100)250-200 (100)250-200 (100)250-200 (100) 250-140 (100)

    1-phase, 220-240 V/220 V, 50 Hz

    Galvanised steel plate

    VP25 (External Dia, 32/Internal Dia, 25)

    38

  • 7/24/2019 Daikin VRV Catalog 131014

    41/84

    FXHQ32MAVE FXHQ63MAVE FXHQ100MAVE

    1-phase, 220-240 V/220 V, 50 Hz

    3,100 6,100 9,600

    12,300 24,200 38,200

    3.6 7.1 11.2

    3,400

    13,600

    4.0

    6,900

    27,300

    8.0

    10,800

    42,700

    12.5

    White (10Y9/0.5)

    12/10 17.5/14 25/19.5

    424/353 618/494 883/688

    36/31 39/34 45/37

    195960680 1951,160680 1951,400680

    24.0 28.0 33.0

    VP20 (External Dia, 26/Internal Dia, 20)

    Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.

    Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.

    FXMQ200MVE FXMQ200MVE

    76,400

    19,300

    22.4 28.0

    95,500

    24,100

    1-phase, 220-240 V/220 V, 50 Hz

    Galvanised steel plate

    58/50

    2,047/1,765

    470X1,380X1,100

    137

    9.5

    19.1

    PS1B

    72/62

    2,542/2,189

    470X1,380X1,100

    137

    9.5

    22.2

    132-221 191-2702 2

    48/45 48/45

    Sound level:(FXMQ-MA)Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.(FXHQ-MA)Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.

    During actual operation, these values are normally somewhat higher as a result of ambient conditions 1: Power consumption values are based on conditions of standard external static pressure.

    2: External static pressure is changeable to change over the connectors inside electrical box, this pressure means "Standard-High static pressure".

    21,500

    85,30025.0

    27,100

    107,50031.5

    Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.

    cfm

    Pa

    mm

    kg

    mm

    kcal/h

    Btu/h

    kW

    kcal/h

    Btu/hkW

    Liquid (Flare)

    Gas (Flare)

    Drain

    Casing

    m3/min

    Dimensions (HWD)

    Machine weight

    Pipingconnections

    Power supply

    Heating capacity

    Cooling capacity

    MODEL

    External static pressure

    Sound level(H/L)

    cfm

    dB(A)

    mm

    kg

    mm

    kcal/h

    Btu/h

    kW

    kcal/h

    Btu/h

    kW

    Liquid (Flare)

    Gas (Flare)

    Drain

    Casing

    m3/min

    Dimensions (HWD)

    Machine weight

    Pipingconnections

    Power supply

    Heating capacity

    Cooling capacity

    MODEL

    Sound level (H/L)

    220 V dB(A)

    Airflow rate (H/L)

    Airflow rate (H/L)

    Ceiling Mounted Duct Type

    Ceiling Suspended Type

    6.4

    12.7 15.9 15.9

    9.5 9.5

    39

  • 7/24/2019 Daikin VRV Catalog 131014

    42/84

    SPECIFICATIONS

    VRV INDOOR UNITS

    Wall Mounted Type

    Floor Standing Type/Concealed Floor Standing Type

    FXLQ

    FXNQ

    Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.

    Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.

    Sound level: (FXAQ-P)Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.(FXLQ-MA, FXNQ-MA)Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m.

    During actual operation, these values are normally somewhat higher as a result of ambient conditions.

    FXAQ20PVE FXAQ25PVE FXAQ32PVE FXAQ40PVE FXAQ50PVE FXAQ63PVE

    1-phase, 220-240 V/220 V, 50 Hz

    1,900 2,400 3,100 3,900 4,800 6,100

    7,500 9,600 12,300 15,400 19,100 24,200

    2.2 2.8 3.6 4.5 5.6 7.1

    2,200

    8,500

    2.5

    2,800

    10,900

    3.2

    3,400

    13,600

    4.0

    4,300

    17,100

    5.0

    5,400

    21,500

    6.3

    6,900

    27,300

    8.0

    2,200

    8,500

    2.5

    2,800

    10,900

    3.2

    3,400

    13,600

    4.0

    4,300

    17,100

    5.0

    5,400

    21,500

    6.3

    6,900

    27,300

    8.0

    White (3.0Y8.5/0.5)

    7.5/4.5 8/5 8.5/5.5 12/9 15/12 19/14

    265/159 282/177 300/194 424/318 530/424 671/494

    35/31 36/31 38/31 42/3739/34 47/41

    290795238 290795238 290795238 2901,050238 2901,050238 2901,050238

    11.0 11.0 11.0 14.0 14.0 14.0

    6.4 6.4 6.4 6.4 6.4 9.5

    12.7 12.7 12.7 12.7 12.7 15.9

    VP13 (External Dia, 18/Internal Dia, 13)

    FXLQ50MAVE

    FXNQ50MAVE

    FXLQ40MAVE

    FXNQ40MAVE

    FXLQ32MAVE

    FXNQ32MAVE

    FXLQ25MAVE

    FXNQ25MAVE

    FXLQ20MAVE

    FXNQ20MAVE

    FXLQ63MAVE

    FXNQ63MAVE

    1-phase, 220-240 V/220 V, 50 Hz

    1,900 2,400 3,100 3,900 4,800 6,100

    7,500 9,600 12,300 15,400 19,100 24,200

    2.2 2.8 3.6 4.5 5.6 7.1

    FXLQ: Ivory white (5Y7.5/1)/FXNQ: Galvanised steel plate

    7/6 7/6 8/6 11/8.5 14/11 16/12

    247/212 247/212 282/212 388/300 494/388 565/424

    35/32 35/32 35/32 38/33 39/34 40/35

    6001,000222 6001,000222 6001,140222 6001,140222 6001,420222 6001,420222

    610930220 610930220 6101,070220 6101,070220 6101,350220 6101,350220

    25.0 25.0 30.0 30.0 36.0 36.0

    19.0 19.0 23.0 23.0 27.0 27.0

    6.4 6.4 6.4 6.4 6.4 9.5

    12.7 12.7 12.7 12.7 12.7 15.9

    21O.D.

    cfm

    dB(A)

    mm

    kg

    mm

    kcal/h

    Btu/h

    kW

    kcal/h

    Btu/h

    kW

    Liquid (Flare)

    Gas (Flare)

    Drain

    Casing

    m3/min

    Dimensions (HWD)

    Machine weight

    Pipingconnections

    Power supply

    Heating capacity

    Cooling capacity

    MODEL

    Sound level (H/L)

    Casing

    Power supply

    Heating capacity

    Cooling capacity

    MODEL

    Airflow rate (H/L)

    cfm

    dB(A)

    kcal/h

    Btu/h

    kW

    kcal/h

    Btu/h

    kW

    Liquid (Flare)

    Gas (Flare)

    Drain

    Machine weight

    Pipingconnections

    Sound level (H/L)

    Dimensions(HWD)

    FXLQ

    220 V

    FXNQ

    FXLQ

    FXNQ

    mm

    kg

    mm

    Airflow rate (H/L)m3/min

    40

  • 7/24/2019 Daikin VRV Catalog 131014

    43/84

    Rp1 (PS 1B internal thread)

    Long-life filter (anti-mould resin net)

    Belt drive system

    3-phase 4-wire system, 380415 V, 50 Hz

    Ivory white (5Y7.5/1)

    FXVQ125MY1

    1,670750510

    115

    52

    15.9 (Brazing)

    FXVQ250MY1 FXVQ400MY1

    1,9001,4707201,9001,170720

    225

    64

    12.7 (Brazing)

    28.6 (Brazing)

    FXVQ200MY1

    12,000

    47,800

    14.0

    13,800

    54,600

    16.0

    19,300

    76,400

    22.4

    21,500

    85,300

    25.0

    24,100

    95,500

    28.0

    27,100

    107,500

    31.5

    38,700

    154,000

    45.0

    43,000

    171,000

    48,200

    191,000

    50.0

    1,6701,170510

    165

    59

    22.2 (Brazing)

    1,670950510

    140

    55

    9.5 (Brazing)

    19.1 (Brazing)

    5.5

    172

    6,072

    FXVQ500MY16

    56.0

    54,200

    215,000

    63.0

    15.9 (Brazing)

    28.6 (Brazing)

    0.75

    43

    1,518

    1.5

    69

    2,436

    1.5

    86

    3,036

    3.7

    134

    4,730

    480150 210 270 380

    295

    67

    Notes: Specifications are based on the following conditions;Cooling : Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB.Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.*1 Sound level : measured when the air discharge outlet duct (2 m) is attached (anechoic chamber conversion value).

    It increases by approximately 5 dB(A) when the plenum chamber is installed to deliver direct airflow.*2 The value is the external static pressure with standard pulley.

    mm

    kg

    dB(A)

    mm

    mm

    mm

    kW

    m3/min

    cfm

    Pa

    kcal/h

    Btu/h

    kW

    kcal/h

    Btu/h

    kW

    Liquid

    Gas

    Drain

    Type

    Motor output

    Airflow rate

    External static pressure *2

    Drive system

    Casing colour

    Sound level *1

    Dimensions (HWD)

    Machine weight

    Pipingconnections

    Power supply

    Heating capacity

    Cooling capacity

    MODEL

    Air filter

    Fan

    Floor Standing Duct Type

    41

  • 7/24/2019 Daikin VRV Catalog 131014

    44/84

    OUTDOOR UNITS

    SPECIFICATIONS

    RXYQ6TRY6(E)RXYQ8TRY6(E) RXYQ10TRY6(E) RYXQ12TRY6(E) RXYQ14TRY6(E) RXYQ16TRY6(E)

    13,800

    54,600

    16.0

    15,500

    61,400

    18.0

    19,300

    76,400

    22.4

    21,500

    85,300

    25.0

    24,100

    95,500

    28.0

    27,100

    107,000

    31.5

    28,800

    114,000

    33.5

    32,300

    128,000

    37.5

    34,400

    136,000

    40.0

    38,700

    154,000

    45.0

    38,700

    154,000

    45.0

    43,000

    171,000

    50.0

    185

    55

    5.9

    185

    56

    5.9

    195

    57

    6.0

    195

    59

    6.3

    285

    60

    10.3

    285

    61

    10.4

    1 1 1 1

    119 157 165 178 233 233

    2 2

    Normal (Space Saving) Type

    1,657X930X765 1,657X930X765 1,657X930X765 1,657X930X765 1,657X1,240X7651,657X1,240X765

    3-phase 4-wire system, 380415 V, 50 Hz

    Hermetically Sealed Scroll Type

    12.7(Brazing)

    19.1(Brazing)

    9.5(Brazing)

    22.2(Brazing)

    28.6(Brazing)

    -5 to 49-20 to 15.5

    R-410A

    Note: Specifications are based on the following conditions;

    Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.

    Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.

    During actual operation, these values are normally somewhat higher as a result of ambient conditions.

    Ivory white (5Y7.5/1)

    MODEL

    Power supply

    Capacity control % 20-100 20-100 16-100 15-100 11-100 10-100

    Compressor

    Dimensions (HWD)

    Machine weight

    Sound level

    Refrigerant

    Pipingconnections

    kcal/h

    Btu/h

    kW

    kcal/h

    Btu/h

    kW

    kg

    dB(A)

    CDB

    CWB

    kg

    m/min

    mm

    Charge

    Type

    Type

    Liquid

    Gas

    mm

    mm

    Combination units

    Cooling capacity

    Heating capacity

    No. of

    compressor

    Airow rate

    Operationrange

    Cooling

    Heating

    Casing colour

    42

  • 7/24/2019 Daikin VRV Catalog 131014

    45/84

    HEAT PUMP

    Normal (Space Saving) Type

    RXYQ10TRY6(E)

    RXYQ12TRY6(E)

    RXYQ12TRY6(E)

    RXYQ12TRY6(E)

    RXYQ18TRY6(E) RXYQ20TRY6(E) RXYQ22TRY6(E) RXYQ24TRY6(E)

    233

    43,000

    171,000

    50.0

    48,200

    191,000

    56.0

    1,657X1,240X765 1,657X1,240X765

    300

    62

    11.7

    48,200

    191,000

    56.0

    54,200

    215,000

    63.0

    320

    65

    11.8

    268

    52,900

    210,000

    61.5

    59,300

    235,000

    69.0

    (1,657X930X765)+

    (1,657X930X765)

    195+195

    61

    6.0+6.3

    165+178

    57,600

    229,000

    67.0

    64,500

    256,000

    75.0

    (1,657X930X765)+

    (1,657X930X765)

    195+195

    62

    6.3+6.3

    178+178

    22 22

    15.9(Brazing)

    28.6(Brazing)

    15.9(Brazing)

    28.6(Brazing)

    15.9(Brazing)

    28.6(Brazing)

    15.9(Brazing)

    34.9(Brazing)

    3-phase 4-wire system, 380415 V, 50 Hz

    Hermetically Sealed Scroll Type

    -5 to 49

    -20 to 15.5

    R-410A

    Note: Specifications are based on the following conditions;

    Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.

    Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.

    During actual operation, these values are normally somewhat higher as a result of ambient conditions.

    Ivory white (5Y7.5/1)

    MODEL

    Power supply

    Capacity control % 10-100 8-100 8-100 8-100

    Compressor

    Dimensions (HWD)

    Machine weight

    Sound level

    Refrigerant

    Pipingconnections

    kcal/h

    Btu/h

    kW

    kcal/h

    Btu/h

    kW

    kg

    dB(A)

    CDB

    CWB

    kg

    m/min

    mm

    Charge

    Type

    Type

    Liquid mm

    Gas mm

    Combination units

    Cooling capacity

    Heating capacity

    Airow rate

    Operationrange

    Cooling

    Heating

    Casing colour

    No. of

    compressor

    43

  • 7/24/2019 Daikin VRV Catalog 131014

    46/84

    OUTDOOR UNITS

    Normal (Space Saving) Type

    62,300

    247,000

    72.4

    69,700

    276,000

    81.0

    67,500

    268,000

    78.5

    75,300

    299,000

    87.5

    71,800

    285,000

    83.5

    80,400

    319,000

    93.5

    77,000

    305,000

    89.5

    86,900

    345,000

    101

    81,700

    324,000

    95.0

    91,200

    362,000

    106

    86,000

    341,000

    100

    96,300

    382,000

    112

    RXYQ12TRY6(E)

    RXYQ16TRY6(E)

    RXYQ8TRY6(E)

    RXYQ18TRY6(E)

    RXYQ28TRY6(E) RXYQ30TRY6(E)RXYQ32TRY6(E) RXYQ34TRY6(E) RXYQ36TRY6(E)RXYQ26TRY6(E)

    (1,657X930X765)+

    (1,657X1,240X765)(1,657X930X765)+

    (1,657X1,240X765)(1,657X930X765)+

    (1,657X1,240X765)(1,657X930X765)+

    (1,657X1,240X765)(1,657X1,240X765)+

    (1,657X1,240X765)

    (1,657X1,240X765)+

    (1,657X1,240X765)

    185+300

    63

    5.9+11.7

    195+285

    63

    6.3+10.4

    195+300

    64

    6.3+11.7

    195+320

    66

    6.3+11.8

    285+300

    65

    10.4+11.7

    300+300

    65

    11.7+11.7

    RXYQ12TRY6(E)

    RXYQ18TRY6(E)

    RXYQ12TRY6(E)

    RXYQ20TRY6(E)

    RXYQ16TRY6(E)

    RXYQ18TRY6(E)

    RXYQ18TRY6(E)

    RXYQ18TRY6(E)

    157+233 178+233 178+233 178+268 233+233 233+233

    43333 4

    Note: Specifications are based on the following conditions;

    Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.

    Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.During actual operation, these values are normally somewhat higher as a result of ambient conditions.

    19.1(Brazing)

    34.9(Brazing)

    19.1(Brazing)

    34.9(Brazing)

    19.1(Brazing)

    34.9(Brazing)

    19.1(Brazing)

    34.9(Brazing)

    19.1(Brazing)

    34.9(Brazing)

    19.1(Brazing)

    41.3(Brazing)

    3-phase 4-wire system, 380415 V, 50 Hz

    Hermetically Sealed Scroll Type

    -5 to 49

    -20 to 15.5

    R-410A

    Ivory white (5Y7.5/1)

    MODEL

    Power supply

    Capacity control % 7-100 6-100 6-100 5-100 5-100 5-100

    Compressor

    Dimensions (HWD)

    Machine weight

    Sound level

    Refrigerant

    Pipingconnections

    kcal/h

    Btu/h

    kW

    kcal/h

    Btu/h

    kW

    kg

    dB(A)

    CDB

    CWB

    kg

    m/min

    mm

    Charge

    Type

    Type

    Liquid mm

    Gas mm

    Combination units

    Cooling capacity

    Heating capacity

    No. of

    compressor

    Airow rate

    Operationrange

    Cooling

    Heating

    Casing colour

    SPECIFICATIONS

    44

  • 7/24/2019 Daikin VRV Catalog 131014

    47/84

    HEAT PUMP

    RXYQ20TRY6(E)

    RXYQ20TRY6(E)

    RXYQ12TRY6(E)

    RXYQ12TRY6(E)

    RXYQ18TRY6(E)

    RXYQ12TRY6(E)

    RXYQ12TRY6(E)

    RXYQ20TRY6(E)

    RXYQ12TRY6(E)

    RXYQ16TRY6(E)

    RXYQ18TRY6(E)

    RXYQ12TRY6(E)

    RXYQ18TRY6(E)

    RXYQ18TRY6(E)

    RXYQ12TRY6(E)

    RXYQ18TRY6(E)

    RXYQ20TRY6(E)

    RXYQ18TRY6(E)

    RXYQ20TRY6(E)

    RXYQ38TRY6(E) RXYQ40TRY6(E) RXYQ42TRY6(E) RXYQ44TRY6(E) RXYQ46TRY6(E) RXYQ48TRY6(E) RXYQ50TRY6(E)

    233+268

    91,200

    362,000

    106

    102,000

    406,000

    119

    (1,657X1,240X765)+

    (1,657X1,240X765)

    (1,657X1,240X765)+

    (1,657X1,240X765)

    300+320

    67

    11.7+11.8